• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • Tagged with
  • 39
  • 39
  • 34
  • 29
  • 12
  • 12
  • 12
  • 10
  • 9
  • 9
  • 7
  • 7
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito de bolhas e de transporte na morfologia do silício corroído anisotropicamente.

Alvimar da Silveira Louro 00 December 2001 (has links)
Esta tese descreve um estudo da corrosão anisotrópica do silício monocristalino em solução de KOH. As superfícies sendo corroídas foram observadas em tempo real com um vídeo-microscópio, e foram medidos parâmetros Tb e Ram de bolhas produzidas na reação para correlacionar com a respectiva rugosidade resultante. O objetivo dessas medidas foi testar experimentalmente um modelo que atribui a maior parte da rugosidade ao mascaramento aleatório das superfícies por bolhas aderidas. Em alguns experimentos foi adicionado K3Fe(CN)6 às soluções de KOH para investigar o efeito desse aditivo nos parâmetros de bolhas e na rugosidade resultante da superfície corroída. Também foram feitas corrosões eletroquímicas para testar o efeito do potencial externo sobre as bolhas e as superfícies corroídas. A observação em tempo real também permitiu investigar as ocorrências, em corrosões de silício nas quais a ponta de um fio de platina foi mantida encostada, ou perto da superfície sendo corroída, para verificar se o aumento da velocidade de corrosão, observado nessas circunstâncias, é devido, talvez, ao aprisionamento de bolhas na ponta do fio. Os resultados deste trabalho mostram que os parâmetros de bolhas Tb e Ram assim como a rugosidade resultante das superfícies corroídas tendem a diminuir com o aumento da concentração de KOH na solução e com o aumento da temperatura. Isto mostra que a relação entre rugosidade e bolhas existe, como sugerido pelos autores da referência [6]. No entanto a simples diminuição dos parâmetros de bolhas não é suficiente para garantir superfície corroída com baixa rugosidade. Deve-se considerar a quantidade de bolhas produzidas na superfície. Poucas bolhas não significa que a superfície corroída estará ausente de marcas, pois nos espaços onde não há formação de bolhas pode haver formação de pirâmides que deixam a superfície corroída com rugosidade bastante elevada. A adição de K3Fe(CN)6 às soluções de KOH ou o uso de potencial anódico no silício suprime a formação dessas pirâmides.
2

Avaliação da rugosidade superficial após o emprego de diferentes métodos de descontaminação da superfívie em discos de titânio = estudo in vitro / Evaluation of surface roughness after use different methods the decontamination on surface of titanium discs

Diefenbach, Ana Lúcia 16 August 2018 (has links)
Orientador: Márcio Zaffalon Casati / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T22:38:20Z (GMT). No. of bitstreams: 1 Diefenbach_AnaLucia_M.pdf: 6428742 bytes, checksum: 0c06242da8f41dfb2cd02646ac4e0208 (MD5) Previous issue date: 2010 / Resumo: Os procedimentos capazes de descontaminar a superfície implantar removendo o biofilme garantem o sucesso e a longevidade dos implantes. As conseqüências na rugosidade superficial gerada por esses procedimentos têm sido avaliadas, porém novas propostas para descontaminação das superfícies implantares vêm sendo utilizadas, principalmente para o tratamento da periimplantite. Assim, objetivo deste trabalho foi avaliar, in vitro, a rugosidade superficial de discos cilíndricos de titânio após uso de cureta plástica; jato de bicarbonato; esfregaço de tetraciclina e ultrassom piezoelétrico. Foram utilizados 50 discos de titânio com dimensões de 5 mm de altura por 5 mm de largura, com superfícies jateadas com óxido de alumínio. Os discos foram divididos aleatoriamente em cinco grupos experimentais. Grupo 1(n=10) controle - sem tratamento; grupo 2(n=10) - recebeu 15 movimentos de raspagem com cureta plástica; grupo 3(n=10) - aplicação de jato de bicarbonato por 30s a cinco milímetros da superfície; grupo 4(n=10) - aplicação de tetraciclina ácida 50mg/ml por esfregaço vigoroso por 30 segundos e grupo 5(n=10) - aplicação de 15 movimentos de raspagem por meio de ultrassom piezoelétrico com irrigação de solução polidora. Após o procedimento foram realizadas três leituras paralelas e três perpendiculares ao sentido da instrumentação utilizando rugosímetro, visando à obtenção dos valores de rugosidade superficial nos parâmetros de Ra e Rz. Os discos foram avaliados em Microscopia Eletrônica de Varredura,para a visualização da topografia superficial após os procedimentos. A análise estatística foi realizada utilizando o teste Kruskall-Wallis com um nível de significância de 5% para comparação dos valores de rugosidade superficial de cada grupo. A análise dos dados mostrou que o menor valor de rugosidade Ra foi obtido no grupo do ultrassom piezoelétrico (0.89±0.06 µm) em relação ao grupo controle (0.85±0.03 µm). O uso de tetraciclina ácida foi o tratamento que provocou maior rugosidade (0.99±0.09 µm) sendo estatisticamente diferente do grupo controle (p_0,05). Em relação ao parâmetro Rz, os resultados mostraram que o esfregaço de tetraciclina e a cureta plástica obtiveram os maiores valores de Rz (8.37±0.76 µm e 8.49±0.74µm; respectivamente) estatísticamente diferentes ao grupo controle (7.33±0.34 µm) com significância de 5%. Além disso, o uso do ultrassom piezoelétrico (7.85±0.69 µm), nos valores de Rz, não promoveu uma alteração significativa na superfície de forma a ser estatisticamente diferente do grupo controle. O estudo conclui que uso do ultrassom piezoelétrico não promoveu aumento significativo da rugosidade superficial dos discos de titânio nos parâmetros de Ra e Rz e que o jato de bicarbonato obteve valores estatísticamente semelhantes aos grupos 1, 2,4 e 5 nos dois parâmetros avaliados. O grupo da cureta plástica e esfregaço de tetraciclina ácida geraram valores estatísticamente superiores em relação ao controle e ultrassom piezoelétrico no parâmetro Rz. Todos os grupos apresentaram visualmente, a partir das fotos em microscopia eletrônica de varredura, alterações em sua superfície / Abstract: Procedures able to decontaminate the implant surface decreasing biofilm become essential to the success and longevity of implant therapy. The consequences of surface roughness generated by these procedures have been evaluated, but new proposals for decontaminating implant surfaces have been used mainly to treat periimplantite. Thus the objective was to evaluate, in vitro, the surface roughness of cylindrical titanium discs treated by plastic curette; bicarbonate jet; smear tetracycline or piezoelectric ultrasound. A total of 50 titanium discs with dimensions of 5 mm high and 5 mm wide, surfaces blasted with aluminum oxide were used. The discs were randomly divided into five groups: group 1 (n = 10)control - no treatment, group 2 (n = 10) received 15 scraping motions with plastic curette, group 3 (n = 10) application of bicarbonate jet for 30 seconds to five millimeters of distance from the surface and group 4 (n = 10) application of vigorous scraping with 50mg/ml tetracycline acid on the surface of the discs for 30 seconds and group 5 (n = 10) application of 15 scraping movements with teflon tip by ultrasonic piezoelectric with polisher irrigation solution. After treatment, three parallel and three perpendicular readings were taken to the direction of the instrumentation using a rugosimeter in order to obtain surface roughness parameters Ra which represents the arithmetic mean of the absolute values of all deviations from the surface in relation to the median in the area of sampling, and Rz which represents the average between the absolute height of the Five highest peaks and the absolute values of the 5 deepest valleys exist in the length of sampling. Furthermore, the discs were evaluated in scanning electron microscopy, an increase of 100X and 1000X, to visualize the surface topography after the procedures. Statistical analysis was performed using the Kruskal-Wallis test with a significance level of 5% compared to the values of surface roughness of each group. The lowest roughness Ra was obtained in the group of piezoelectric ultrasound (0.89 ± 0.06 µm) compared to control (0.85 ± 0.03 µm). The use of tetracycline acid was the treatment which increased the roughness (0.99 ± 0.09 µm) was statistically different from the control group (p _ 0.05). Regarding the parameter Rz, the results showed that the smear of tetracycline and plastic curette had the highest values of Rz (8.37±0.76 µm e 8.49±0.74µm, respectively) statistically different to control group (7.33 ± 0.34 µm) with significance 5%. Moreover, as the values of Ra, the use of piezoelectric ultrasound (7.85 ± 0.69 µm), the values of Rz, did not cause a significant change in the surface so as to be statistically different in the control group. The study concludes that use of piezoelectric ultrasound did not cause significant increase in surface roughness of titanium discs in the parameters of Ra and Rz. The bicarbonate jet obtained values statistically similar to other groups in both parameters .The group of plastic curette and smear tetracycline acid generated values statistically different from the control and ultrasound in piezoelectric parameter Rz. All groups presented visually, from the pictures on scanning electron microscopy, changes on its surface / Mestrado / Periodontia / Mestre em Clínica Odontológica
3

Influencia da radiação nas propriedades de compositos odontologicos / Influence of radiation on properties of composite restorative resin

Viero, Flavio Luiz 25 July 2006 (has links)
Orientador: Frab Norberto Boscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T22:46:39Z (GMT). No. of bitstreams: 1 Viero_FlavioLuiz_D.pdf: 553886 bytes, checksum: 6455fb7d1e46ecd9328257967d685d33 (MD5) Previous issue date: 2006 / Resumo: O objetivo neste estudo foi avaliar o efeito de diferentes doses de radiação X produzida a partir do Cobalto -60, em dois tipos de materiais odontológicos: o compósito Filtek TM A 110 3M, utilizado para restauração d e dentes anteriores; e o compósito condensável SureFilTM indicado para restauração cB dentes posteriores. Foram confeccionados 70 corpos de prova, dos quais 25 foram destinados ao teste de dureza Knoop e 50 ao teste de rugosidade de superfície. Depois de confeccionados, os corpos de prova foram acondicionados em caixas de acrílico e submersos em água destilada por um período de 24 horas, tendo com finalidade obter-se a estabilização química dos materiais. Após esse período, foram submetidos ao teste de Microdureza e de rugosidade de superfície. Obtidas essas medidas, os corpos de prova foram submetidos à irradiação, com as seguintes doses: 0,25Gy; 0,50Gy; 0,75Gy; 1Gy. Passadas 24 horas da irradiação, os mesmos 25 corpos de prova foram novamente submetidos ao teste de microdureza e os mesmos 50 éD teste de rugosidade. Logo após a realização do teste de rugosidade, os 50 corpos de prova foram submetidos à abrasão, sendo a seguir submersos em água destilada, permanecendo por 24 horas. Após esse período, um terceiro teste de rugosidade de superfície foi realizado nesses corpos de prova. De posse das medidas obtidas e após estas serem submetidas à análise estatística - Teste Tukey e o teste T pareado, observou-se que os tipos de compósitos irradiados apresentaram uma redução estatisticamente significante, nos valores de dureza Knoop, quando comparados ao material não irradiado; entretanto não foi observada diferença significante entre os grupos irradiados. Quando avaliada a rugosidade, observou-se que não houve diferença entre o grupo controle e o irradiado; entretanto houve diferença estatisticamente significante, dentro de cada grupo, antes e após os corpos de prova terem sido submetidos à abrasão. Conclui-se que, portanto, que a irradiação influenciou a dureza Knoop, mas não interferiu na rugosidade dos dois compósitos avaliados / Abstract: The aim of the present study was to evaluate the effects of different )f radiation doses produced by cobalt-60 teletherapy unit on two types of restorative dental materials: 3M Filtek TM A 110 used for forward teeth restorations and condensable SureFilTM used for back teeth restorations. Seventy five specimens were fabricated, 25 were submitted to Knoop hardness test and 50 to surface roughness. Next, the samples were immersed in distilled water in an acrylic support for chemical stabilization for 24 hours, and evaluated before irradiation test. Afterwards the samples were submitted to microhardness test and to surface roughness. Subsequently, samples were irradiated with single doses of 0,25Gy; O,50Gy; 0,75Gy; 1Gy. Twenty four hours after irradiation, the same samples were evaluated considering both tests - roughness and microhardness. After these procedures, the 50 samples used for the roughness surface evaluation were submitted to abrasion and stored in distilled water for 24 hours. After this period, the roughness surface were again analyzed. Data were submitted to Tukey test and to paired t-test, and it was observed that the two irradiated composites had a statistically significant reduction in Knoop hardness values when compared to non­irradiated composites adversely, no statically significant differences were found among the irradiated groups. Regarding surface roughness, no statistically significant difference was observed in the comparisons between the control group and irradiated group, however statistically significant differences were found inside each group, before and after the samples have been submitted to abrasion. It was concluded that the x-irradiation influenced the Knoop hardness, therefore it did not interfere on the surface roughness of the two restorative composite evaluated. / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
4

Influência da rugosidade e energia livre de superfície de materiais para próteses removíveis a base de polimetilmetacrilato nas propriedades do biofilme de Candida albicans / Influence of the roughness and free energy surfasse of the materials for removable prosthesis the base of polymethymethacrylate in the properties of biofilm of Candida albicans

Leal, Cristiane Maria Brasil, 1965- 18 August 2018 (has links)
Orientador: Célia Marisa Rizzatti Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T20:42:48Z (GMT). No. of bitstreams: 1 Leal_CristianeMariaBrasil_D.pdf: 1004692 bytes, checksum: 29697b5c7bdbece2ba32ca361de7e805 (MD5) Previous issue date: 2011 / Resumo: As propriedades de superfície de resinas e reembasadores a base de polimetilmetacrilato utilizados em próteses dentais removíveis podem interferir na adesão, colonização e formação do biofilme de Candida spp., microrganismo associado à estomatite protética. O objetivo desta pesquisa foi avaliar a influência da rugosidade e da energia livre de superfície de uma resina a base de polimetilmetacrilato e um reembasador rígido na adesão e estrutura de biofilmes de Candida albicans. Discos de resina acrílica termopolimerizável e de reembasador rígido à base de polimetilmetacrilato foram confeccionados nas dimensões de 10 x 2 mm. As diferentes rugosidades de superfície dos espécimes foram obtidas por meio de diferentes acabamento/polimento. A energia livre de superfície variou pela formação de películas de saliva ou plasma ou a combinação de ambos sobre os espécimes. Após a mensuração da rugosidade e da energia livre de superfície, os espécimes foram divididos aleatoriamente de acordo com os grupos experimentais. Biofilmes de Candida albicans ATCC 90028 foram formados sobre as superfícies e avaliados quanto à contagem celular, bioatividade e arquitetura (bio-volume, espessura média e rugosidade média) nas fases de adesão e após 48 horas. Os dados foram analisados utilizando-se a análise de variância a dois critérios seguido do teste de Tukey. O nível de significância foi de p=0,05. Os resultados revelaram que mesmo havendo diferenças significantes (p<0,001) entre os valores da rugosidade, isto não se refletiu nos parâmetros avaliados do biofilme de C. albicans no período de 48 horas. Não houve diferença significativa nos valores da energia livre de superfície, no entanto, a diferença das películas provocou alterações significativas do biofilme de C. albicans na fase de adesão e 48 horas (p>0,05). Pode-se concluir que a alteração da rugosidade de superfície não afeta a estrutura do biofilme de C. albicans de 48 horas, no entanto, a alteração da energia livre de superfície por meio da deposição de proteínas salivares e/ou plasmáticas altera a estrutura do biofilme nas fases de adesão e 48 horas / Abstract: The properties of surface of the resins and reliners base of polymethymethacrylate used in removable dental prosthesis can interfere in the adhesion, colonization and formation of biofilm of Candida spp., microorganism associated to the prosthetic stomatitis. The objective of this research was to evaluate the influence of the roughness and the free energy of surface of the resin the base of polymethymethacrylate and a rigid reliner in the adhesion and structure of biofilms of C. albicans. Discs of the termopolymerized acrylic resin and rigid reliner to the base of polymethymethacrylate had been confectioned in the dimensions 10 x 2 mm. The differents roughness of surface of the specimens were obtained by means of different finishing/polishing. The free energy of surface varied for the formation of pellicle of saliva or serum or the combination of both on the specimens. After the measurement the roughness and the free energy of surface, the specimens were divided randomly in accordance to the experimental groups. Biofilms of Candida albicans ATCC 90028 were formed on the surfaces and evaluated for cell count, bioactivity and architecture (bio-volume, average thickness and average roughness) in the adhesion phases and after 48 hours. The data were analyzed using analysis of variance with two criteria followed by the Tukey test. The significance level was p=0,05. The results showed that even with significant differences (p<0.001) between the values of roughness, it did not reflect in the parameters evaluated of biofilm of C. albicans in 48 hours. There was no significant difference in the values of the free energy of surface; however, the difference of the pellicles caused significant alterations of biofilm of C. albicans in the adhesion phase and 48 hours (p>0,05). It can be concluded that the alteration of the roughness of surface don't affect the structure of biofilm of C. albicans of 48 hours, however, the alteration of the free energy of surface by deposition of salivary and/or serum proteins modifies the structure of biofilm in the adhesion phases and 48 hours / Doutorado / Protese Dental / Doutor em Clínica Odontológica
5

Degradação de materiais restauradores estéticos em um modelo de ciclagem de ph e abrasão por escovação / Degradation of esthetic restorative materials in a pH cycling model and toothbrush abrasion

Davidoff, Denise Cesar de Oliveira, 1962- 18 August 2018 (has links)
Orientador: Regina Maria Puppin Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T23:48:30Z (GMT). No. of bitstreams: 1 Davidoff_DeniseCesardeOliveira_D.pdf: 3958488 bytes, checksum: 9a1e41592f3bdc48fc01bc4174934e72 (MD5) Previous issue date: 2011 / Resumo: Os objetivos nesta tese, composta por 2 capítulos foram: (1) avaliar a influencia da proteção de superfície na dureza, rugosidade e morfologia de um cimento de ionômero de vidro submetidos a degradação química e mecânica; (2) avaliar os efeitos do desafio químico (ciclagem de pH) e mecânico (abrasão por escovação) na dureza e rugosidade de diferentes materiais restauradores. No capitulo 1, trinta e seis espécimes obtidos do CIV foram distribuídos em 4 grupos (n=8) de acordo com a proteção de superfície (com ou sem proteção de vaselina) e meio de armazenagem (ciclagem de pH e água deionizada). Todos os espécimes foram submetidos a mensuração de microdureza e rugosidade de superfície (Ra) em três momentos inicial, apos armazenagem por 15 dias e apos abrasão por escovação mecânica. Os dados foram submetidos aos testes ANOVA 3 fatores para medidas repetidas e Tukey-Kramer (p<0,05). Os resultados de ciclagem de pH evidenciaram que houve diminuição dos valores de dureza independente do fator proteção. A ciclagem de pH não promoveu alteração nos valores de rugosidade para o grupo sem proteção. O cimento de ionômero de vidro de alta viscosidade apresentou diminuição na dureza apos abrasão e ciclagem de pH independente da proteção de superfície com vaselina. No capitulo 2, foram confeccionados dezesseis espécimes de cada material (Ketac Molar Easy Mix, Vitremer, Ketac N100 e Filtek Z350) divididos em 8 grupos (n=8) de acordo com o material e o meio de armazenagem: ciclagem de pH e água deionizada. Foram mensuradas a microdureza e rugosidade de superfície de todos os materiais estudados em três momentos: inicial, apos armazenagem por 15 dias e apos abrasão por escovação mecânica. Os dados foram submetidos a ANOVA 3 fatores para medidas repetidas e teste de Tukey-Kramer (p<0,05). Os resultados mostraram que todos os materiais avaliados apresentaram diminuição dos valores de dureza apos ciclagem de pH. O Filtek Z350 apos abrasão apresentou os maiores valores de dureza, e os demais materiais valores equivalentes. O Ketac N100 não apresentou alteração na dureza quando submetido a abrasão e ciclagem de pH. O Ketac Molar Easy Mix não apresentou alteração nos valores de rugosidade apos degradação química e mecânica, enquanto os Ketac N100, Filtek Z350 e Vitremer apresentaram aumento de rugosidade. Com base nos resultados pode-se concluir que a influencia da abrasão por escovação mecânica e da ciclagem de pH na degradação de superfície dos materiais restauradores estéticos esta relacionada ao tipo de material: o compósito Filtek Z350 foi o material que exibiu a maior resistência a degradação química e mecânica em relação a rugosidade e dureza, apresentando menores índices de rugosidade. O Ketac N100 apresentou valores equivalentes de dureza e rugosidade ao Vitremer apos abrasão e ciclagem de pH. O Ketac Molar Easy Mix apresentou diminuição na dureza apos abrasão e ciclagem de pH, independente da proteção superficial com vaselina. O Ketac Molar Easy Mix sem proteção superficial com vaselina não apresentou diminuição de rugosidade apos abrasão associada a ciclagem de pH / Abstract: The objectives of this Thesis, consisting of two chapters, were: (1) to evaluate the effect of petroleum jelly used as a surface protection on hardness and surface roughness of Ketac Molar Easy Mix (KM), submitted to chemical and mechanical degradation; (2) to evaluate the effect of chemical challenges (pH-cycling) and mechanical degradation (toothbrush abrasion) in hardness and roughness surface of different restorative materials. In chapter one, thirty-two specimens obtained from KM were divided into four groups according to their surface protection (with or without protection) and chemical degradation (pH cycling or water). All specimens were subjected to measurement of microhardness and surface roughness at baseline, after storage and after abrasion. Data were submitted to a three-way ANOVA for repeated measures and Tukey-Kramer's tests (p<0.05). After pH cycling, there was a decrease in hardness regardless the surface protection. The pH cycling did not promote changes in surface roughness for the group without protection. KM showed a decrease in hardness and abrasion after pH cycling, independently of surface protection. pH-cycling provided the lowest microhardness regardless surface protection or abrasion. The highest microhardness point was obtained when KM was protected and submitted to water storage and abrasion. The highest roughness point was obtained when unprotected KM was submitted to water immersion and/or abrasion compared with KM and submitted to pH cycling. Conclusion: Microhardness and surface roughness were influenced by surface protection and chemical degradation. There was an increase in surface roughness when KM was unprotected. In chapter 2, sixteen specimens were obtained from each material (Ketac Molar Easy Mix, Vitremer, Ketac N100 and Filtek Z350) and were divided into 8 groups according to the material and the storage. All specimens were submitted to the measurement of hardness and roughness in three different treatments: initial, after storage and after abrasion. The data were submitted to repeated measures three-way ANOVA and Tukey's tests (p<0.05). Results showed that all materials presented a decrease in hardness after pH cycling. The Filtek Z350 after abrasion presented the highest surface hardness and the others did not present statistically significant difference. The Ketac N100 was the only material that showed no change in hardness when submitted to pH cycling and abrasion, while the others, KM, Vitremer and Filtek Z350, showed a decrease in hardness. The KM did not change the roughness after chemical and mechanical degradation, while Ketac N100, Filtek Z350 and Vitremer increased surface roughness. Filtek Z350 was the material that showed the best resistance to chemical and mechanical degradation. Based on the results it can be concluded that the influence of abrasion and pH cycling on surface degradation of aesthetic restorative materials is related to the type of material: Filtek Z350 exhibited the highest resistance to chemical and mechanical degradation concerning roughness and hardness. Ketac N100 and Vitremer showed similar values of hardness and roughness after abrasion and pH cycling. KM had a decrease in hardness and abrasion after pH cycling, independently of surface protection. KM with no surface protection did not show a decrease of roughness after abrasion associated with pH cycling / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
6

Análise da rugosidade superficial de diferentes marcas comerciais de resina acrílica para coroas provisórias / Surface roughness analysis of acrylic resin for provisional crowns under different commercial brands

Nishida, Cintia Lumi 30 June 2010 (has links)
As coroas provisórias apresentam algumas características que podem comprometer a estética e facilitar aderência de microorganismos e formação de placa. Estudos prévios demonstraram que a forma de processamento influi na rugosidade e porosidade de uma marca comercial de resina acrílica comumente utilizada para a confecção de provisórias. Como diferentes marcas comerciais apresentam diferenças de qualidade, o presente estudo teve como objetivo principal avaliar a rugosidade superficial de quatro marcas comerciais de resina acrílica utilizadas na confecção de coroas provisórias (Dencor, Vipi, Duralay e Alike) de acordo com quatro técnicas de manipulação, diretas e indiretas. Os processamentos avaliados foram: GRUPO I autopolimerização sob pressão em matriz de silicona; GRUPO II - autopolimerização térmica em mufla; GRUPO III autopolimerização utilizando a técnica do pincel; GRUPO IV autopolimerização pela mistura em pote dappen. Para cada tipo de processamento foram confeccionados 12 corpos-deprova de cada material, totalizando 48 corpos-de-prova para cada grupo e 192 espécimes ao total. Logo após a confecção dos espécimes foi realizado o teste de rugosidade de superfície (Ra) através de um rugosímetro/perfilômetro. Posteriormente, a superfície dos mesmos foi uniformizada e polida com a utilização de politriz, realizando-se novamente os mesmos testes de rugosidade. Antes do acabamento e polimento de superfície, os resultados encontrados apontaram a maior rugosidade para resina Vipi (4,074 ± 0,541) e técnica da mistura em dappen gupo IV (3,538 ± 0,509), enquanto que a menor rugosidade foi encontrada para resina Alike (2,671 ± 0,512) e técnica da prensagem em mufla grupo II (2,733 ± 0,470). Após acabamento e polimento, a maior rugosidade foi encontrada para resina Vipi (0,207 ± 0,032) e técnica da pressão grupo I (0,172 ± 0,037), enquanto que a menor rugosidade para resina Alike (0,113 ± 0,036) e técnica da prensagem em mufla grupo II (0,138 ± 0,027). Com os resultados obtidos, foi possível concluir que a melhor combinação para confecção de coroas provisórias em resina acrílica foi a técnica da prensagem em mufla associada à resina Alike. / Provisional crowns have some features that may compromise aesthetics and favors adherence of microorganisms and dental plaque formation. Previous studies have shown that processing may influence roughness and porosity of acrylic resins commonly used make provisional crowns. Because the several commercial resins available present differences in their quality the aim of this study was to evaluate the surface roughness of four commercial brands of acrylic resins (Dencor, Vipi, Duralay and Alike) according to four manipulation techniques (two direct and two indirect): GROUP I - autopolimerization under pressure in a silicone matrix; GROUP II autppolimerization in flask; GROUP III - autopolimerization using the bead brush technique; GROUP IV - autopolimerization after mixing in dappen dish. For each type of processing 12 specimens were made of each material, being 48 specimens for each group and 192 specimens in total. After specimens preparation, surface roughness tests (Ra) was performed using a rugosimeter / profilometer. Posteriorly, all surfaces were polished for standardization and same roughness tests were performed again. Before finishing and polishing, the results pointed out that Vipi resin presented the highest roughness (4.074 ± 0.541). Mixing the resin in dappen dish group IV (3.538 ± 0.509) also presented the highest roughness values regarding the technique. The lowest roughness values were found with Alike resin (2.671 ± 0.512) and flask technique group II (2.733 ± 0.470). After finishing and polishing techniques, the highest roughness was found with Vipi resin (0.207 ± 0.032) and the autopolimetization under pressure in silicone matrix technique - group I (0.172 ± 0.037). The lowest roughness values were found with Alike resin (0.113 ± 0.036) and flask technique group II (0.138 ± 0.027). With these results, it was possible to conclude that the best combination for making provisional crowns was the flask technique associated with Alike resin.
7

Parâmetros de rugosidade aerodinâmica sobre vegetação esparsa / Aerodynamic roughness parameters over sparse vegetation

Lyra, Gustavo Bastos 16 February 2006 (has links)
Para vegetação esparsa e de porte alto a determinação dos parâmetros de rugosidade é comprometida pela dificuldade em se observar condições que satisfaçam a lei logarítmica da velocidade do vento. Estimou-se o comprimento de rugosidade (z0) e o deslocamento do plano zero (d) por alguns métodos com medidas micrometeorológicas e da estrutura física de arbustos esparsos em região semi-árida, durante o experimento HAPEX-Sahel. A velocidade do vento foi medida em quatro alturas acima da superfície (3,0; 4,1; 5,3 e 8,5 m), e os fluxos determinados por correlações dos turbilhões a 9m de altura. Métodos baseados no perfil logarítmico foram aplicados em condições de atmosfera neutra. A altura média da vegetação era h = 2,06 ± 0,47 m. O método convencional (ajuste estatístico) resultou em estimativas satisfatórias de d e z0 em condições nas quais a validade do perfil logarítmico foi satisfeita. Com uma única altura de medida localizada acima da subcamada inercial as estimativas resultaram em valores ou fisicamente inconsistentes ou que não caracterizam a rugosidade da superfície. Quando se utilizou a velocidade de fricção dada pela correlação dos turbilhões na solução do perfil logarítmico, as estimativas melhoraram. A combinação do perfil logarítmico com a relação z0 = &#955; (h - d) proporcionou estimativas satisfatórias para os valores de &#955; = 0,188 e 0,190 determinados em função da estrutura física da vegetação, o que não foi observado para o valor médio da literatura (0,166). Relações entre a estrutura física da vegetação e o transporte de momentum estimaram apropriadamente d e z0. A rugosidade da área foi melhor descrita por d = 0,95 m = 0,46 h e z0 = 0,204 m = 0,1 h, sendo &#955; = 0,185. As velocidades horizontal do vento e de fricção foram mais sensíveis a variações em z0 do que em d. / For sparse and tall vegetation the estimate of roughness parameters is compromised by the difficulty in observing conditions that satisfy the windspeed logarithmic law. The roughness length (z0) and the zero-plane displacement (d) were estimated by some methods with micrometeorological measurements and the physical structure of sparse shrubs in semi-arid region, during the HAPEX-Sahel experiment. The wind speed was measured at four heights above of surface (3.0, 4.1, 5.3 and 8.5 m), and the turbulent flows determined by eddy correlations at the height of 9m. Methods based on the logarithmic profile have been applied in neutral atmosphere conditions. The average height of the vegetation was h = 2.06 ± 0.47 m. The conventional method (statistical fit) resulted in good estimates of d and z0 only under conditions of validity of the logarithmic law. Only one height of measurement located above of the inertial sublayer is enough to result in physically inconsistent values. When the friction velocity, given by eddy correlation, was used in the logarithmic law, the estimates improved. The combination of the logarithmic law with z0 = &#955; (h - d) provided satisfactory estimates of the surface roughness for &#955; = 0.188 and 0.190 determined in function of the physical structure of the vegetation; but for &#955; = 0.166, the average value of literature, the estimates where not good. Relationships between the physical structure of the vegetation and the momentum transfer estimated appropriately d and z0. The area roughness was better described by d = 0.95 m = 0.46 h and z0 = 0.204 m = 0.1 h, being &#955; = 0.185. Wind speed and friction velocity were more sensible to variations in z0 than in d.
8

Avaliação clínica do efeito de dentifrícios clareadores na cor e rugosidade do esmalte dental e compósitos odontológicos / Clinical evaluation of color and surface roughness of dental enamel and dental composites submitted to brushing with whitening toothpaste

Roselino, Lourenço de Moraes Rego 11 August 2015 (has links)
Os objetivos deste estudo foram avaliar clinicamente a alteração de cor e de rugosidade de superfície do esmalte dental e de compósitos odontológicos, submetidos à escovação com dentifrícios clareadores e a ação deles sobre a degradação das pontas das cerdas da escova dental. Foram obtidos 30 corpos-de-prova (6mm de diâmetro X 2mm de espessura) de cada compósito (Z250 e Z350, 3M ESPE e Tetric N-Ceram, Ivoclar Vivadent). Em seguida, estes foram aleatoriamente fixados na face vestibular dos primeiros molares superiores (direito e esquerdo) e de um segundo molar superior (direito ou esquerdo) de 30 participantes selecionados para o estudo, de acordo com os critérios de inclusão determinados. Após a fixação dos espécimes, os participantes receberam escovas de dentes (Oral B Classic, Procter & Gamble) e dentifrício convencional (Sorriso Dentes Brancos, Colgate-Palmolive) e foram orientados a utilizar esses produtos durante 7 dias (período pré-experimental) após o qual foram realizadas as leituras iniciais de cor (Easyshade, VITA) e de rugosidade de superfície (Rugosímetro Surfcorder SE 1700, Kosakalab) das amostras e também do esmalte dental de um dos incisivos centrais superiores dos participantes. Para as leituras de rugosidade foi realizada moldagem (Express, 3M ESPE) do incisivo central superior e dos corpos-de-prova fixados para posterior obtenção de modelos com resina de poliuretano (Axon F16, Abcol) para confecção de réplicas, sobre as quais foram realizadas as leituras. Após as leituras iniciais, os participantes foram separados em 3 grupos (n=10), conforme o dentifrício clareador utilizado: Grupo 1) Dentifrício controle (Sorriso Dentes Brancos); Grupo 2) Dentifrício clareador (Colgate Luminous White, Colgate-Palmolive); e Grupo 3) Dentifrício clareador de ação rápida (Close up White Now, Unilever). As cerdas das escovas dentais utilizadas pelos participantes foram analisadas por MEV (Microscópio XL30 Field Emission Gun, Philips), em duas regiões da escova: periférica e central. Os períodos de análise da ação dos dentifrícios clareadores foram, 7, 30 e 90 dias. Os valores das medições (antes e após os períodos de testes) foram analisados estatisticamente (3-way-ANOVA, medidas repetidas, Tukey, p<0,05) e os resultados demonstraram que não houve alteração de cor significativa dos substratos analisados independentemente do tipo de dentifrício utilizado, mas o tempo de utilização de um dentifrício sobre os compósitos foi significante para a alteração de cor. Não houve alteração de rugosidade de superfície do esmalte dental, independente do dentifrício utilizado. A alteração de rugosidade de superfície dos compósitos é material dependente, mas o tempo de escovação com esses dentifrícios não interfere nessa propriedade. Quanto maior o tempo de escovação, maior o desgaste da ponta das cerdas da escova, independente do dentifrício utilizado e da região a que ela pertence. Conclui-se que a alteração de cor e de rugosidade de superfície dos compósitos é material-dependente e tempo-dependente para a alteração de cor e para degradação das cerdas da escova. / The aims of this study were to clinically evaluated the color change and the surface roughness of enamel and dental composites submitted to brushing with whitening toothpaste and the their action over the degradation of the tips of the bristles of the toothbrush. 30 specimens were obtained (6 mm diameter X 2mm thick) of each composite (Z250 and Z350, 3M ESPE and Tetric N-Ceram, Ivoclar Vivadent). Then, the specimens were randomly bonded on the maxillary first molars buccal surfaces (right and left sides) and the one maxillary second molar (right or left sides) of 30 participants, which were selected for the study according to inclusion criteria. After specimens bonding, participants received toothbrush (Oral B Classic, Procter & Gamble) and non whitening toothpaste (Sorriso Dentes Brancos, Colgate-Palmolive) and also they were instructed to use these products for 7 days (pre-trial). After that, were realized the initial color (Easyshade, VITA) and surface roughness (Roughness Surfcorder SE 1700, KosakaLab) readings of specimens and of the enamel of the maxillary central incisors of the participants. For surface roughness readings was performed molding (Express, 3M ESPE) of the maxillary central incisor and of the specimens fixed to be retrieved later of the models with polyurethane resin (Axon F16, Abcol). Then in these replicas were made surface roughness readings. After baseline measurements, participants were divided into 3 groups (n=10), according to the whitening toothpaste used: Group 1) Control toothpaste (Sorriso Dentes Brancos); Group 2) Whitening toothpaste (Colgate Luminous White, Colgate-Palmolive); and Group 3) Whitening toothpaste with fast action (Close up White Now, Unilever). The bristles of toothbrushes used by the participants were analyzed by SEM (Field Emission Gun Microscope XL30, Philips) in two regions of the brush: peripheral and central. The periods of action analysis of whitening toothpaste were 7, 30 and 90 days. The measured values (before and after the testing periods) were statistically analyzed (3-way ANOVA, repeated measures, Tukey, p <0.05) and the results showed no significant color change of the substrates analyzed independently of the type toothpaste used, but the time of use of a dentifrice over the composites was significant for the color change. There was no surface roughness change enamel independently of the toothpaste used. The surface roughness change of composites is dependent on material, but the time of brushing with these toothpaste does not interfere in this property. The longer the time of brushing, the greater the degradation in the tips of the bristles of the toothbrush independently of the toothpaste used and the region to which it belongs. It is conclude that the color change and surface roughness of the composites is material-dependent and time-dependent to color change and to degradation of the brush bristles.
9

Análise da estabilidade de cor e rugosidade de superfície de compósitos submetidos à fumaça de cigarro / Color stability and surface roughness of dental composites exposed to cigarette smoke

Román, Carla Cecília Alandia 29 November 2011 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor e rugosidade de superfície de 3 compósitos odontológicos com partículas diferentes: nanohíbrido (Tetric N-Ceram - Ivoclar Vivadent), híbrido (Z250 - 3M ESPE) e microhíbrido com matriz silorano (Filtek P90 3M - ESPE), submetidos à fumaça de cigarro. Para isso, foram obtidos 60 corpos-de-prova (8mm de diâmetro X 2mm de espessura), 20 para cada tipo de material restaurador utilizado, dos quais 10 receberam polimento com lixas dágua em abrasividades decrescentes (Grupo1) e a outra metade não foi submetida a nenhum tipo de acabamento/polimento ficando sob efeito apenas de uma matriz de poliéster (Grupo 2). Após armazenamento dos corpos de prova em água destilada a 37°C por 24 horas, foram realizadas as primeiras leituras de cor (Colorímetro Vita Easy Shade) na escala de cor CIEL*a*b* e rugosidade superficial (Rugosímetro Surfcorder SE 1700 - Kosakalab). Em seguida, as amostras foram expostas à fumaça de 20 cigarros por um período de 10 minutos cada, (Marlboro - Philip Morris), sendo que entre um cigarro e outro as amostras foram submetidas à escovação em dispositivo padronizado e lavagem em água corrente. Após ação do número total de cigarros, foram realizadas leituras finais de cor e rugosidade. Os valores de &Delta;E, &Delta;L, &Delta;a e &Delta;b foram analisados estatisticamente utilizando 2 way ANOVA e Teste de Bonferroni (p<0.05) e os valores de rugosidade média (Ra) foram analisados isoladamente para cada tipo de material (teste t Student, p < 0.05). Verificou-se que o compósito Tetric N apresentou maior alteração de cor, em níveis clinicamente inaceitáveis (&Delta;E>3,3) e de rugosidade de superfície em relação aos demais compósitos quando utilizada a tira de poliéster como acabamento. Concluiu-se que a ausência de polimento aumenta a capacidade manchadora do cigarro sobre todos os compósitos e a rugosidade de superfície dos materiais, com exceção de P90. / The purpose of this study was to evaluate the color stability and surface roughness of three dental composites with different type of fillers: Nanohybrid (Tetric N-Ceram), Hybrid (Filtek Z250-3M ESPE) and Microhybrid silorane based composite (Filtek P90- 3M ESPE), exposed to cigarette smoke. 20 specimens (8mm diameter X 2mm thickness) of each material were prepared and separated into two groups (n=10) according to the surface treatment : Group 1- polymerization through a polyester film strip and polishing with water sandpaper in decreasing abrasiveness (600, 800 e 1200); and Group 2- polymerization through a polyester film strip, without any polishing. After immersion in destilled water 37° for 24 hours, baseline color of all specimens was measured using reflectance spectrophotometer (Easy Shade - Vita) with CIEL*a*b* system, surface roughness was also measured using a rugosimeter (SJ-201P Mitutoyo, Tokyo, Japan). After base line measurements, the specimens were exposed to smoke from 20 cigarettes in 10 minutes each, (Marlboro - Philip Morris), between one cigarette and other, the specimens were submitted to brushing in a standardized device and washed with water. After the action of the total number of cigarettes, final measurements of color and surface roughness were performed. Values of &Delta;E, &Delta;L, &Delta;a e &Delta;b were statistically analyzed using 2 way ANOVA e Teste de Bonferroni (p<0.05) and values of average surface roughness (Ra) were analyzed separately for each type of material (teste t Student, p < 0.05). It was found that the composite Tetric N-Ceram showed increased of surface roughness and greater color change in clinically unacceptable levels (&Delta;E>3,3), in comparison with the other composites when used the polyester strip without polishing. It was concluded that the absence of polishing increases the cigarette staining and surface roughness on all composites except for Filtek P90.
10

Avaliação clínica do efeito de dentifrícios clareadores na cor e rugosidade do esmalte dental e compósitos odontológicos / Clinical evaluation of color and surface roughness of dental enamel and dental composites submitted to brushing with whitening toothpaste

Lourenço de Moraes Rego Roselino 11 August 2015 (has links)
Os objetivos deste estudo foram avaliar clinicamente a alteração de cor e de rugosidade de superfície do esmalte dental e de compósitos odontológicos, submetidos à escovação com dentifrícios clareadores e a ação deles sobre a degradação das pontas das cerdas da escova dental. Foram obtidos 30 corpos-de-prova (6mm de diâmetro X 2mm de espessura) de cada compósito (Z250 e Z350, 3M ESPE e Tetric N-Ceram, Ivoclar Vivadent). Em seguida, estes foram aleatoriamente fixados na face vestibular dos primeiros molares superiores (direito e esquerdo) e de um segundo molar superior (direito ou esquerdo) de 30 participantes selecionados para o estudo, de acordo com os critérios de inclusão determinados. Após a fixação dos espécimes, os participantes receberam escovas de dentes (Oral B Classic, Procter & Gamble) e dentifrício convencional (Sorriso Dentes Brancos, Colgate-Palmolive) e foram orientados a utilizar esses produtos durante 7 dias (período pré-experimental) após o qual foram realizadas as leituras iniciais de cor (Easyshade, VITA) e de rugosidade de superfície (Rugosímetro Surfcorder SE 1700, Kosakalab) das amostras e também do esmalte dental de um dos incisivos centrais superiores dos participantes. Para as leituras de rugosidade foi realizada moldagem (Express, 3M ESPE) do incisivo central superior e dos corpos-de-prova fixados para posterior obtenção de modelos com resina de poliuretano (Axon F16, Abcol) para confecção de réplicas, sobre as quais foram realizadas as leituras. Após as leituras iniciais, os participantes foram separados em 3 grupos (n=10), conforme o dentifrício clareador utilizado: Grupo 1) Dentifrício controle (Sorriso Dentes Brancos); Grupo 2) Dentifrício clareador (Colgate Luminous White, Colgate-Palmolive); e Grupo 3) Dentifrício clareador de ação rápida (Close up White Now, Unilever). As cerdas das escovas dentais utilizadas pelos participantes foram analisadas por MEV (Microscópio XL30 Field Emission Gun, Philips), em duas regiões da escova: periférica e central. Os períodos de análise da ação dos dentifrícios clareadores foram, 7, 30 e 90 dias. Os valores das medições (antes e após os períodos de testes) foram analisados estatisticamente (3-way-ANOVA, medidas repetidas, Tukey, p<0,05) e os resultados demonstraram que não houve alteração de cor significativa dos substratos analisados independentemente do tipo de dentifrício utilizado, mas o tempo de utilização de um dentifrício sobre os compósitos foi significante para a alteração de cor. Não houve alteração de rugosidade de superfície do esmalte dental, independente do dentifrício utilizado. A alteração de rugosidade de superfície dos compósitos é material dependente, mas o tempo de escovação com esses dentifrícios não interfere nessa propriedade. Quanto maior o tempo de escovação, maior o desgaste da ponta das cerdas da escova, independente do dentifrício utilizado e da região a que ela pertence. Conclui-se que a alteração de cor e de rugosidade de superfície dos compósitos é material-dependente e tempo-dependente para a alteração de cor e para degradação das cerdas da escova. / The aims of this study were to clinically evaluated the color change and the surface roughness of enamel and dental composites submitted to brushing with whitening toothpaste and the their action over the degradation of the tips of the bristles of the toothbrush. 30 specimens were obtained (6 mm diameter X 2mm thick) of each composite (Z250 and Z350, 3M ESPE and Tetric N-Ceram, Ivoclar Vivadent). Then, the specimens were randomly bonded on the maxillary first molars buccal surfaces (right and left sides) and the one maxillary second molar (right or left sides) of 30 participants, which were selected for the study according to inclusion criteria. After specimens bonding, participants received toothbrush (Oral B Classic, Procter & Gamble) and non whitening toothpaste (Sorriso Dentes Brancos, Colgate-Palmolive) and also they were instructed to use these products for 7 days (pre-trial). After that, were realized the initial color (Easyshade, VITA) and surface roughness (Roughness Surfcorder SE 1700, KosakaLab) readings of specimens and of the enamel of the maxillary central incisors of the participants. For surface roughness readings was performed molding (Express, 3M ESPE) of the maxillary central incisor and of the specimens fixed to be retrieved later of the models with polyurethane resin (Axon F16, Abcol). Then in these replicas were made surface roughness readings. After baseline measurements, participants were divided into 3 groups (n=10), according to the whitening toothpaste used: Group 1) Control toothpaste (Sorriso Dentes Brancos); Group 2) Whitening toothpaste (Colgate Luminous White, Colgate-Palmolive); and Group 3) Whitening toothpaste with fast action (Close up White Now, Unilever). The bristles of toothbrushes used by the participants were analyzed by SEM (Field Emission Gun Microscope XL30, Philips) in two regions of the brush: peripheral and central. The periods of action analysis of whitening toothpaste were 7, 30 and 90 days. The measured values (before and after the testing periods) were statistically analyzed (3-way ANOVA, repeated measures, Tukey, p <0.05) and the results showed no significant color change of the substrates analyzed independently of the type toothpaste used, but the time of use of a dentifrice over the composites was significant for the color change. There was no surface roughness change enamel independently of the toothpaste used. The surface roughness change of composites is dependent on material, but the time of brushing with these toothpaste does not interfere in this property. The longer the time of brushing, the greater the degradation in the tips of the bristles of the toothbrush independently of the toothpaste used and the region to which it belongs. It is conclude that the color change and surface roughness of the composites is material-dependent and time-dependent to color change and to degradation of the brush bristles.

Page generated in 0.11 seconds