• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • Tagged with
  • 39
  • 39
  • 34
  • 29
  • 12
  • 12
  • 12
  • 10
  • 9
  • 9
  • 7
  • 7
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação da rugosidade e microdureza de superfície de compósitos restauradores submetidos a dois tipos de polimentos / Evaluation of the surface roughness and microhardness of composites submitted to two polishing techniques

Patrícia Schunck Alferes Marques 26 June 2009 (has links)
Objetivo: Comparar compósitos diretos e indiretos em relação à rugosidade de superfície e microdureza Knoop e a efetividade de sistemas de polimento multipasso e passo único sobre a superfície destes materiais. Método: Foram confeccionados 34 corpos-de-prova para cada material, sendo dois compósitos restauradores para uso direto e dois para uso indireto. A análise inicial da rugosidade de superfície foi realizada em vinte corpos-de-prova de cada material restaurador, com o rugosímetro Surftest SV-3000, filtro de 0,25mm (cut-off) e comprimento de leitura de 1,25mm. A microdureza inicial foi mensurada em dez corpos-de-prova de cada grupo, com uso de um microdurômetro MVD 401, sob carga de cinquenta gramas por 12 segundos. Quatro corpos-de-prova de cada compósito foram submetidos à análise topográfica por microscopia de força atômica. Ao final das análises iniciais de rugosidade de superfície e microdureza Knoop, os corpos-de-prova foram igualmente divididos em dois subgrupos conforme o sistema de polimento a ser empregado: sistema de passo único (Pontas Pogo) e sistema multi-passo (Discos Sof-lex). Após o polimento, foi realizada nova análise da rugosidade de superfície, da microdureza Knoop e microscopia de força atômica. As médias obtidas nos ensaios foram submetidas à Análise de Variância (ANOVA) e ao teste t de student, nível de significância de 5%. Resultados: Os valores médios da rugosidade (Ra - μm) após polimento com Sof-Lex variaram de 0,13μm (Sinfony) a 0,29μm (Charisma). Após polimento com Pogo, variaram de 0,13μm (Charisma) a 0,20μm (Sinfony), sem diferença estatística entre os compósitos testados. Para o teste do microdureza Knoop, os valores médios (Kg/mm2) após polimento com Sof-Lex variaram entre 18,86 (Sinfony) e 68,67 (Filtek Z350), sendo que o compósito Filtek Z350 foi associado a valores estatisticamente superiores quando comparado aos demais compósitos. Não foram observadas diferenças estatísticas entre os compósitos Charisma e Signum, e o compósito Sinfony apresentou médias de dureza estatisticamente inferiores. Após o polimento com Pogo, as médias variaram de 18,95 (Sinfony) a 64,34 (Filtek Z350), sendo que diferenças estatísticas foram observadas entre todos os compósitos avaliados, na seguinte ordem decrescente: Filtek Z350, Charisma, Signum e Sinfony. Conclusões: O polimento com Sof-Lex foi mais efetivo na redução da rugosidade para os compósitos indiretos, sendo que não foram observadas diferenças entre os compósitos após polimento com Pogo. A efetividade do sistema de polimento na redução da rugosidade de superfície está mais relacionada com características individuais dos compósitos que com a classificação. O polimento realizado tanto com Sof-Lex como com Pogo causou em todos os compósitos (com exceção do Signum) uma redução significativa na microdureza de superfície. / Objective: The aim of the present study was to compare direct and indirect composites in relation to the superficial topography and Knoop microhardness and to evaluate the effectiveness of polishing techniques (multi-step and single-step) on the surface of these materials. Method: Four commercially available resin composites were tested, two direct and two indirect composites. For each material, 34 samples were confectioned. The initial analysis of roughness was performed in twenty samples of each restorative material, using a Surftest SV-3000 profilometer, with parameters of 0.25μm (cut-off) and 1.25mm (length of reading). The initial microhardness was measured in ten samples of each group, using a microhardness unit MVD 401, under load of fifty grams per 12 seconds. Four samples of each resin composite were confectioned to Atomic Force microscopy (AFM). After initial analysis, samples were randomly divided in two sub-groups in agreement to the polishing technique used: single-step polishing (Pogo - Dentsply) or multi-step polishing (Sof-lex - 3M ESPE). After polishing, final measurements of roughness, microhardness and AFM were performed. Results were analyzed by ANOVA and students t test (α = 0.05). Results: The mean values of roughness (Ra - μm) after polishing with Sof-Lex ranged from 0.13μm (Sinfony) to 0.29μm (Charisma), and indirect composites presented statistically lower mean values when compared to direct composites. No statistical difference was observed among composites after polishing using Pogo. The mean values of microhardness after polishing using Sof-Lex varied between 18,86 (Sinfony) and 68,67 (Filtek Z350). Filtek Z350 was associated with higher mean values when compared to the other composites. No difference between Charisma and Signum was observed, and the composite Sinfony presented the lowest mean value of hardness. After polishing using Pogo, statistically different microhardness values were observed among all evaluated composites, in the following decreasing order: Filtek Z350, Charisma, Signum and Sinfony. Conclusions: Polishing with Sof-Lex was more effective in the reduction of roughness for the indirect composites. However, composites presented similar performance after polishing with Pogo. The effectiveness of the polishing system in the reduction on superficial roughness is more related to individual characteristics of the composite than with its classification. Polishing using Sof-Lex and Pogo caused to all composites (exception to Signum) a significant reduction of the mean microhardness.
32

Efeito da escovação e do envelhecimento artificial acelerado sobre a alteração superficial de materiais restauradores estéticos / Effect of simulated toothbrushing and accelerated artificial aging on surface degradation of aesthetic restorative materials

Roselino, Lourenço de Moraes Rego 11 April 2012 (has links)
O objetivo desse estudo foi avaliar sistematicamente o efeito da escovação simulada e do envelhecimento artificial acelerado (EAA) sobre estabilidade de cor e rugosidade de superfície de compósitos odontológicos de nanopartículas (Z350 - 3M ESPE) e híbrido (Tetric N-Ceram - Ivoclar Vivadent). Foram confeccionados 24 corpos-de-prova (12mm de diâmetro X 2mm de espessura) para cada compósito e uma cerâmica de revestimento (IPS e.max Ceram - Ivoclar Vivadent) como controle. Após sua confecção, os corpos-de-prova foram polidos com lixas d&lsquo;água em abrasividades decrescentes (compósitos = 600, 1200 e 2000 e cerâmica = 100, 320, 1200 e 2000). Em seguida, foram realizadas leituras iniciais de cor (Espectrofotômetro PCB 6807) e rugosidade de superfície (Rugosímetro Surfcorder SE 1700 - Kosakalab). As amostras foram separadas em 3 grupos (n=8), segundo o tratamento a que foram submetidas: Grupo 1: EAA; Grupo 2: escovação mecânica com dentifrício RDA* 68 (Colgate); e Grupo 3: escovação mecânica com dentifrício RDA* 180 (Colgate Total Plus Whitening). Após 480 horas de EAA e em intervalos de 41 minutos de escovação (=14.600 ciclos) até 205 minutos novas leituras de cor e rugosidade de superfície foram realizadas. Amostras inicialmente submetidas a EAA (n=4) receberam escovação mecânica com dentifrício RDA* 68 e 180, conforme metodologia descrita anteriormente e novas leituras de cor e rugosidade foram obtidas. Os dados (antes e após os testes) foram analisados estatisticamente (2-way ANOVA análises repetidas, Bonferroni, p<0,05) e verificou-se que houve maior alteração de cor dos compósitos quando submetidos a EAA com diferença estatisticamente significante (p<0,05) em relação à escovação mecânica. Não houve diferença estatisticamente significante (p>0,05) na estabilidade de cor dos materiais quando comparadas as abrasividades dos dentifrícios, porém esse fator foi significante para a alteração de rugosidade de superfície (p<0,05), sendo maior quando os materiais foram escovados com RDA* 180. Quanto ao tempo de escovação, não houve diferença estatisticamente significante (p>0,05) para a alteração de cor e de rugosidade de superfície dos materiais, o mesmo ocorrendo para amostras escovadas após EAA. Conclui-se que o EAA interfere na estabilidade de cor e a escovação simulada nas alterações de rugosidade de superfície dos compósitos, independente do tempo de utilização do dentifrício, sendo maior para dentifrícios mais abrasivos. Além disso, a abrasividade e o tempo de utilização do dentifrício não alteram a capacidade de remoção do manchamento e a rugosidade de superfície de compósitos. / The purpose of this study was to evaluate the effect of simulated toothbrushing and accelerated artificial aging (AAA) on color stability and surface roughness of nanofill (Z350 - 3M ESPE) and hybrid (Tetric N-Ceram - Ivoclar Vivadent) composites. Twenty-four diskshaped specimens (12mm in diameter X 2 mm thick) were made for each composite and one feldspatic ceramic (IPS e.max Ceram - Ivoclar Vivadent) as a control. The specimens were polished with decreasing abrasiveness sandpapers (composites = 600, 1200, 2000 and ceramic = 100, 320, 1200, 2000). Then, initial readings were taken on color (Spectrophotometer PCB 6807) and surface roughness (Rugosimeter Surfcorder SE 1700 - Kosakalab). The samples were separated in 3 groups (n=8) according to the submitted treatments: Group 1: AAA; Group 2: mechanical brushing with dentifrice RDA* 68 (Colgate); and Group 3: mechanical brushing with dentifrice RDA* 180 (Colgate Total Plus Whitening). New readings on color and surface roughness were taken after 480 hours of AAA and in intervals of 41 minutes of brushing (=14.600 cycles) until 205 minutes. The samples initially submitted to AAA (n=4) received mechanical brushing with dentifrice RDA* 68 and 180, according to previously described methodology and new readings on color and roughness were taken. Data (before and after tests) were statistically analyzed (2- way ANOVA repeated measures, Bonferroni, p<0,05) and it was observed a higher composite color alteration compared with mechanical brushing when submitted to AAA with a statistically significant difference (p<0,05) between them. There was no statistically significant difference (p>0,05) on color stability of materials when the dentifrices abrasiveness were compared, but it was significant for surface roughness degradation (p<0,05), higher when materials were brushed with RDA* 180. Regarding time brushing, there was no statistically significant difference (p>0,05) for color alteration and roughness surface of materials and the same occurred for samples brushed after AAA. It was concluded that AAA interferes on color stability and the simulated brushing on surface roughness degradation of composites regardless the time of used dentifrice, but it was higher for more abrasive dentifrices. Moreover, abrasiveness and time of used dentifrice do not alter the capacity of staining removal and the surface roughness of composites.
33

Influencia das fontes e tempos de fotoativação sobre a pigmentação e propriedades fisico-quimica e morfologica de diferentes tipos de resina composta / Influence of light curing exposure times and devices on the discoloration and on the physical-chemical and morphologic properties of different types of composite resins

Santos-Daroz, Claudia Batitucci dos 15 August 2018 (has links)
Orientadores: Giselle Maria Marchi Baron, Flavio Henrique Baggio de Aguiar, William Michael Johnston / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T10:15:56Z (GMT). No. of bitstreams: 1 Santos-Daroz_ClaudiaBatituccidos_D.pdf: 5048631 bytes, checksum: 73770753e4e1725beb03729a21bf12c9 (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi avaliar o efeito da fonte de luz (FL) e tempo de fotoativação sobre a pigmentação, grau de conversão (GC), microdureza (KHN) e rugosidade de superfície (Ra) de diferentes tipos de resinas compostas. Espécimes (2,0 mm de altura e 5,0 mm de diâmetro) foram confeccionados a partir de diferentes tipos de resinas compostas (RC) [Nanoparticuladas: Filtek Supreme Plus A2D and Filtek Supreme XT A2E (3M ESPE); Microparticulada: Durafill A2 (Heraeus Kulzer); Microhíbridas: Filtek Z250 A2 (3M ESPE) e Venus A2 (Heraeus Kulzer)], utilizando-se dois tipos de fontes de luz, halógena (Optilux 501 - Demetron) e LED (Elipar FreeLight 2 - 3M ESPE) e com diferentes tempos de fotoativação (metade do tempo, dobro do tempo e tempo recomendado pelo fabricante). Após 24h, realizou-se acabamento e polimento. GC e cor inicial foram averiguados nas superfícies de topo (T) e base (B). Posteriormente, os espécimes foram armazenados em vinho tinto. Avaliação da alteração da cor (Sistema CIE L*a*b*) foi determinada após 1, 2, 7, 14, 20 e 30 dias no vinho. KHN e Ra foram determinados nas superfícies de topo e base antes e após armazenagem em vinho por 30 dias. Todos os fatores estudados foram estatisticamente significantes (ANOVA / Stepdown Bonferroni / Bonferroni Correction), havendo interações quádrupla (Resina X Luz X Superfície X Dias; p = 0,042) na avaliação da alteração de cor; e triplas, para GC (Luz X Resina X Tempo; p = 0,05; Luz X Resina X Superfície; p = 0,02), KHN (Luz X Resina X Superfície; p = 0,05; Luz X Resina X Vinho; p < 0,0001; Resina X Tempo X Superfície; p = 0,008) e Ra (Luz X Resina X Superfície; p = 0,045; Luz X Tempo X Vinho; p = 0,0008; Resina X Tempo X Superfície; p < 0,0001; Resina X Tempo X Vinho; p = 0,047; Resina X Vinho X Superfície; p = 0,022). A pigmentação da superfície de base foi significantemente maior que da superfície de topo para todos os tipos de RC e FL. A polimerização pelo dobro do tempo reduziu a pigmentação da base de dois tipos de RC. Observou-se diferença significante no GC entre T e B e a dureza do T foi maior que da B. Após armazenamento no vinho, houve diminuição da dureza do T. Não se observou diferença significante no Ra entre T e B; no entanto, após estocagem em vinho, o Ra da base da RC microparticulada foi significantemente aumentado, independentemente do tempo de fotoativação e FL utilizada. A fotopolimerização pelo dobro do tempo recomendado parece influenciar no grau de pigmentação da base de alguns materiais resinosos, porém, não foi capaz de manter a dureza da superfície de topo após armazenagem no vinho. Diferenças entre as FL depende do tipo de resina composta e tempo de fotoativação utilizado / Abstract: The objective of the present study was to evaluate the effect of LCU and light curing time on the discoloration, degree of conversion (DC), microhardness (KHN) and surface roughness (Ra) of different types of composite resins. Specimens (2.0 mm of height; 5.0 mm of diameter) were fabricated from different types of composite resins (CR) [Nanofilled: Filtek Supreme Plus A2D and Filtek Supreme XT A2E (3M ESPE); Microfilled: Durafill A2 (Heraeus Kulzer); Microhybrid: Filtek Z250 A2 (3M ESPE) and Venus A2 (Heraeus Kulzer)], using two types of LCUs; halogen (Optilux 501 - Demetron) and LED (Elipar FreeLight 2 - 3M ESPE) with different light curing times (half of-, double of- and the time recommended by the manufacturer). After 24h, specimens were finished and polished. DC and the initial color were evaluated at both the top (T) and bottom (B) surfaces. Further, the specimens were stored in red wine. The color change (CIE L*a*b* System) was established after 1, 2, 7, 14, 20 e 30 days in the wine. KHN and Ra were evaluated at both the top and the bottom surfaces before and after the storage in the wine for 30 days. All factors studied were a statistically significant factor (ANOVA / Stepdown Bonferroni / Bonferroni Correction), with quadruple interaction (Resin X Light X Surface X Days; p = 0.042) for the color change evaluation; and triple interaction for DC (Light X Resin X Time; p = 0.05; Light X Resin X Surface; p = 0.02), KHN (Light X Resin X Surface; p = 0.05; Light X Resin X Wine; p < 0.0001; Resin X Time X Surface; p = 0.008) and Ra (Light X Resin X Surface; p = 0.045; Light X Time X Wine; p = 0.0008; Resin X Time X Surface; p < 0.0001; Resin X Time X Wine; p = 0.047; Resin X Wine X Surface; p = 0.022). The discoloration of the bottom surface was significantly higher than the top surface for all types of CR and LCU. The light curing for double of the recommended time reduced the discoloration from the bottom surface of two types of CRs. Significant difference was observed between the DC of the T and B; and the hardness of T was higher than B. After the wine storage, the hardness of T was diminished. No significant difference in Ra between T and B was observed; however, after the storage in the wine, the Ra from the bottom surface of the microfilled composite was significantly higher, regardless the light curing time and LCU used. The lightcuring for double of the recommended time seems to influence on the degree of color change of the bottom surface of some composite materials, however, it was not capable to keep the hardness of the top surface after storage in the wine. The differences between the LCUs are dependent on the type of composite resin and light curing time used / Doutorado / Dentística / Doutor em Clínica Odontológica
34

Efeito da escovação e do envelhecimento artificial acelerado sobre a alteração superficial de materiais restauradores estéticos / Effect of simulated toothbrushing and accelerated artificial aging on surface degradation of aesthetic restorative materials

Lourenço de Moraes Rego Roselino 11 April 2012 (has links)
O objetivo desse estudo foi avaliar sistematicamente o efeito da escovação simulada e do envelhecimento artificial acelerado (EAA) sobre estabilidade de cor e rugosidade de superfície de compósitos odontológicos de nanopartículas (Z350 - 3M ESPE) e híbrido (Tetric N-Ceram - Ivoclar Vivadent). Foram confeccionados 24 corpos-de-prova (12mm de diâmetro X 2mm de espessura) para cada compósito e uma cerâmica de revestimento (IPS e.max Ceram - Ivoclar Vivadent) como controle. Após sua confecção, os corpos-de-prova foram polidos com lixas d&lsquo;água em abrasividades decrescentes (compósitos = 600, 1200 e 2000 e cerâmica = 100, 320, 1200 e 2000). Em seguida, foram realizadas leituras iniciais de cor (Espectrofotômetro PCB 6807) e rugosidade de superfície (Rugosímetro Surfcorder SE 1700 - Kosakalab). As amostras foram separadas em 3 grupos (n=8), segundo o tratamento a que foram submetidas: Grupo 1: EAA; Grupo 2: escovação mecânica com dentifrício RDA* 68 (Colgate); e Grupo 3: escovação mecânica com dentifrício RDA* 180 (Colgate Total Plus Whitening). Após 480 horas de EAA e em intervalos de 41 minutos de escovação (=14.600 ciclos) até 205 minutos novas leituras de cor e rugosidade de superfície foram realizadas. Amostras inicialmente submetidas a EAA (n=4) receberam escovação mecânica com dentifrício RDA* 68 e 180, conforme metodologia descrita anteriormente e novas leituras de cor e rugosidade foram obtidas. Os dados (antes e após os testes) foram analisados estatisticamente (2-way ANOVA análises repetidas, Bonferroni, p<0,05) e verificou-se que houve maior alteração de cor dos compósitos quando submetidos a EAA com diferença estatisticamente significante (p<0,05) em relação à escovação mecânica. Não houve diferença estatisticamente significante (p>0,05) na estabilidade de cor dos materiais quando comparadas as abrasividades dos dentifrícios, porém esse fator foi significante para a alteração de rugosidade de superfície (p<0,05), sendo maior quando os materiais foram escovados com RDA* 180. Quanto ao tempo de escovação, não houve diferença estatisticamente significante (p>0,05) para a alteração de cor e de rugosidade de superfície dos materiais, o mesmo ocorrendo para amostras escovadas após EAA. Conclui-se que o EAA interfere na estabilidade de cor e a escovação simulada nas alterações de rugosidade de superfície dos compósitos, independente do tempo de utilização do dentifrício, sendo maior para dentifrícios mais abrasivos. Além disso, a abrasividade e o tempo de utilização do dentifrício não alteram a capacidade de remoção do manchamento e a rugosidade de superfície de compósitos. / The purpose of this study was to evaluate the effect of simulated toothbrushing and accelerated artificial aging (AAA) on color stability and surface roughness of nanofill (Z350 - 3M ESPE) and hybrid (Tetric N-Ceram - Ivoclar Vivadent) composites. Twenty-four diskshaped specimens (12mm in diameter X 2 mm thick) were made for each composite and one feldspatic ceramic (IPS e.max Ceram - Ivoclar Vivadent) as a control. The specimens were polished with decreasing abrasiveness sandpapers (composites = 600, 1200, 2000 and ceramic = 100, 320, 1200, 2000). Then, initial readings were taken on color (Spectrophotometer PCB 6807) and surface roughness (Rugosimeter Surfcorder SE 1700 - Kosakalab). The samples were separated in 3 groups (n=8) according to the submitted treatments: Group 1: AAA; Group 2: mechanical brushing with dentifrice RDA* 68 (Colgate); and Group 3: mechanical brushing with dentifrice RDA* 180 (Colgate Total Plus Whitening). New readings on color and surface roughness were taken after 480 hours of AAA and in intervals of 41 minutes of brushing (=14.600 cycles) until 205 minutes. The samples initially submitted to AAA (n=4) received mechanical brushing with dentifrice RDA* 68 and 180, according to previously described methodology and new readings on color and roughness were taken. Data (before and after tests) were statistically analyzed (2- way ANOVA repeated measures, Bonferroni, p<0,05) and it was observed a higher composite color alteration compared with mechanical brushing when submitted to AAA with a statistically significant difference (p<0,05) between them. There was no statistically significant difference (p>0,05) on color stability of materials when the dentifrices abrasiveness were compared, but it was significant for surface roughness degradation (p<0,05), higher when materials were brushed with RDA* 180. Regarding time brushing, there was no statistically significant difference (p>0,05) for color alteration and roughness surface of materials and the same occurred for samples brushed after AAA. It was concluded that AAA interferes on color stability and the simulated brushing on surface roughness degradation of composites regardless the time of used dentifrice, but it was higher for more abrasive dentifrices. Moreover, abrasiveness and time of used dentifrice do not alter the capacity of staining removal and the surface roughness of composites.
35

Efeito de pastilhas higienizadoras efervescentes nos componentes da prótese parcial removível / Effect of effervescent denture tablets on the components of partial removable denture

Vasconcelos, Glenda Lara Lopes 09 February 2018 (has links)
Este estudo avaliou os efeitos de pastilhas efervescentes na superfície de liga de cobalto cromo (Co-Cr) e resina termopolimerizável, simulando um período de até 5 anos de imersão, como também analisar sua ação antimicrobiana. A partir de uma matriz metálica, padrões de cera circulares (12 x 3 mm) foram obtidos e fundidos em liga de Co-Cr (DeguDent®). As amostras foram imersas em: Polident 3 minutes® (P3M), Steradent® (St), Polident for Partials® (PP), Efferdent® (Ef), Corega Tabs® (CT), Nitradine® (Ni), Fixodent® (Fi) e Kukident® (K). Foi avaliada a resistência à corrosão (Ecorr, Ipass) (n=5) por meio do Potenciostato/Galvanostato. Foram realizadas análises qualitativas complementares com Microscópio Eletrônico de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios-X (EDS). Após o ensaio de corrosão, cada disco metálico foi incluído em mufla preparada por matrizes circulares de cera (20 x 5 mm), incorporando-o à resina acrílica termopolimerizável (Clássico Ltda®). Os grupos das 4 pastilhas que apresentaram a menor taxa de corrosão e da água destilada (controle) (n=9) foram analisados quanto à rugosidade da superfície metálica e da resina acrílica (Sa, &micro;m) por meio de microscopia confocal a laser. Foram avaliadas a alteração de cor (&Delta;E) da resina por meio de espectrocolorímetro no início e após a simulação de ½, 1, 2, 3, 4 e 5 anos e alteração de massa (g), no início e final, em balança de alta precisão. Para avaliação antimicrobiana, por meio da contagem de Unidades Formadoras de Colônia (UFC/mL), os espécimes mistos foram contaminados com biofilme misto composto por: S. mutans (Sm), S. aureus (Sa), C. albicans (Ca) e C. glabrata (Cg) e, posteriormente, imersos nas soluções higienizadoras, onde foram semeados em meios específicos para contagem das UFC. De acordo com os resultados obtidos (&alpha;=0,05), P3M causou a menor taxa de corrosão e Ni, o menor potencial de corrosão. Com o MEV, verificou-se evidenciação da microestrutura da liga metálica. Quanto à rugosidade superficial do metal, CT (p=0,009) e Ni (p=0,036) causaram aumento na rugosidade em relação ao tempo (Friedman). Na resina, houve aumento da rugosidade após 5 anos (p<0,01). Entre as soluções (Kruskal-Wallis), não houve diferença para ambos os materiais. Não houve diferença na cor da resina acrílica, tanto em relação às soluções (Kruskal Wallis) quanto aos tempos (Friedman). Não foram observadas alterações de massa (Kruskal-Wallis). Quanto à ação antimicrobiana (Kruskal-Wallis), Ni propiciou redução de UFC de Sm (p=0,001). Conclui-se que, embora todas as pastilhas efervescentes não tenham alterado a superfície do metal e da resina acrílica de maneira significativa, nenhuma apresentou ação antimicrobiana contra os microrganismos avaliados do biofilme misto; somente Ni reduziu a quantidade de S. mutans / The aim of this study were: to evaluate the effects of denture cleansers on the surface of cobalt chromium (Co-Cr) and heat-polymerized acrylic resin, simulating a period until 5 years of immersion, as well as to analyze its antimicrobial action. From a metal matrix, disc-shaped wax patterns (12 x 3 mm) were made and later were casting in Co-Cr alloy (DeguDent&trade;). The specimes were immersed in: Polident 3 minutes&trade; (P3M), Steradent&trade; (St), Polident for Partials&trade; (PP), Efferdent&trade; (Ef), Corega Tabs&trade; (CT), Nitradine&trade; (Ni), Fixodent&trade; (Fi) and Kukident&trade; (K). The corrosion resistance (Ecorr, Ipass) (n = 5) was evaluated by Potentiostat / Galvanostat. Further qualitative analyzes were performed with scanning electronic microscopy (SEM) and energy dispersive x-ray spectrometry (EDS). After the corrosion test, each metal disk was included in heat-cured acrylic resin (Clássico Ltda&trade;) using moulds previously prepared from circular wax matrices (20 x 5 mm). The four dentures cleansers with the lowest corrosive potential were analyzed for surface roughness of the metal and acrylic resin (Sa, &micro;m) by laser confocal microscopy. The color change (&Delta;E) of the resin was evaluated by means of a spectrocolorimeter at the beginning and after the simulation of ½, 1, 2, 3, 4 and 5 years and mass change (g), at the beginning and end, in high-precision balance. For antimicrobial evaluation, the mixed specimens (n = 9) were contaminated with multispecies biofilm [S. mutans (Sm), S. aureus (Sa), C. albicans (Ca) and C. glabrata (Cg)] and subsquently immersed in denture cleansers, where they were seeded in specific CFU / mL media. According to the results obtained (&alpha;=0.05), there was a significant difference: P3M presented the lowest corrosion rate and Ni, the lowest corrosion potential. According to SEM, the tablets effervescent provided evidence of the microstructure of the alloy. As for the surface roughness in the metal surface, CT (p = 0.009) and Ni (p = 0.036) showed increase in roughness in relation to time (Friedman). At the resin surface, the roughness growed after 5 years. Among the solutions (Kruskal-Wallis), there was no difference for both materials. There was no difference in the color of the acrylic resin (&delta;E), both for solution (Kruskal-Wallis), and for time (Friedman). Differences in weight weren\'t observed (Kruskal-Wallis). In antimicrobial action (Kruskal-Wallis), Ni group showed significant reduction for Sm (p=0.001). It\'s concluded that, although all the denture cleansers didn\'t significantly changed the surface of the metal and acrylic resin, none showed antimicrobial action against the evaluated microorganisms of the mixed biofilm; only Ni reduced the amount of S. mutans
36

Análise das propriedades físicas e mecânicas de materiais restauradores odontológicos submetidos à ação do calor e do frio para fins periciais / Analysis of physical and mechanical properties of dental restorative materials subjected to the action of heat and cold for forensic purposes

Biancalana, Roberto Cesar 03 June 2015 (has links)
O objetivo deste trabalho foi avaliar o efeito da ação do calor e do frio sobre a estabilidade de cor, rugosidade de superfície e microdureza de restaurações de resina composta (FiltekMR Z250 XT 3M ESPE®), cimento de ionômero de vidro (KetacTM Fil Plus 3M ESPE®) e amálgama de prata em cápsulas (gs-80 SDI®), na tentativa de simular o comportamento desses materiais, quando presentes nos elementos dentais de vítimas carbonizadas ou mortas por congelamento. Foram selecionados 180 dentes bovinos que foram preparados (6 X 6 mm com 2 mm de profundidade) e separados em grupos de 30 dentes, segundo o tipo de material restaurador utilizado. Em seguida, foram realizadas as leituras iniciais de cor (Espectrofotômetro VITA® Easyshade), rugosidade de superfície (Rugosímetro Mitutoyo® Surftest SJ-201P) e microdureza Knoop (Microdurômetro Shimadzu® Micro Hardness Tester HMV-2), que foram consideradas os padrões iniciais. Subsequentemente, os dentes foram separados aleatoriamente em grupos (n=10) segundo a temperatura utilizada para simulação de congelamento (-80°C), (-20°C) e 2,5°C; e carbonização (100°C, 200°C e 300°C). A submissão a altas temperaturas foi realizada pela colocação dos dentes restaurados em forno (ALUMINI Sinter-Press EDG®), pelo período de 15 minutos, e as baixas temperaturas foram realizadas em refrigerador (RFGE 700 GE®) a 2,5°C; congelador (CVU18 Consul®) a (-20°C) e freezer (Ultra Freezer AL 374 - 80V American Lab®) a (-80°C). Após 7 e 30 dias de ação do frio e da submissão ao calor, os dentes foram submetidos às leituras finais de cor, rugosidade e microdureza. No calor, os valores de alteração de cor (&Delta;E*, &Delta;L*, &Delta;a* e &Delta;b*), dos dois materiais estéticos, rugosidade superficial e microdureza dos três materiais restauradores, foram submetidos à análise estatística One-way ANOVA, Tukey (p<0,05), tendo como fator de variação, a temperatura. No frio, os dados foram submetidos à análise estatística 2-way ANOVA, Bonferroni (p<0,05), tendo como fatores de variação, o tempo e a temperatura. Verificou-se que houve alteração de cor dos materiais estéticos, tanto nas submissões ao calor quanto ao frio. Na resina composta, a rugosidade de superfície e a microdureza não se alteraram significantemente (p>0,05), independente da temperatura a que foram submetidos. No CIV, a rugosidade e a microdureza elevaram-se nos testes ao calor; e ao frio, não ocorreram alterações significativas (p>0,05) dessas propriedades. Para o amálgama houve alteração de rugosidade significante (p<0,05) no calor, nas submissões a 300°C; e a microdureza não se modificou. Ao frio não ocorreram mudanças significantes (p>0,05) na rugosidade nem na microdureza do amálgama. Concluiu-se que os materiais estéticos podem ser distinguidos, pela análise de cor, a partir de 200°C até 300°C e quando submetidos a (-80°C), tanto em 7 dias como em 30 dias. O tempo de congelamento não é significativo para a distinção dos materiais. Testes de rugosidade e microdureza podem distinguir os materiais estéticos, independentemente, da ação do calor ou do frio. / The purpose of this study was to evaluate the effect of the action of heat and cold on color stability, surface roughness and microhardness of composite resin (FiltekMR Z250 XT 3M ESPE®), glass ionomer cement (KetacTM Fil Plus 3M ESPE®) and silver amalgam capsules (gs-80 SDI®) restorations, in an attempt to simulate the behavior of these materials when present in dental elements of carbonized or killed by freezing victims. 180 bovine teeth were selected, prepared with a 6 x 6 mm 2 mm cavity and then separated into groups of 30 teeth, according to the type of restorative material. Then, initial color readings (Spectrophotometer VITA® Easyshade), surface roughness (Rugosimeter Mitutoyo® Surftest SJ-201P) and Knoop microhardness (Shimadzu Micro Hardness tester® HMV-2) readings were performed, which were considered the initial standards. Afterwards, the teeth were randomly divided into groups (n=10) according to the temperature used for freezing simulation (-80°C), (-20°C), (2,5°C); and carbonization simulation (100°C, 200°C, 300°C). Submission to high temperatures was performed by placing the restored teeth in an oven (ALUMINI Sinter Press EDG®), for 15 minutes and for low temperatures, a refrigerator (RFGE 700 GE®) at 2,5°C, a freezer (CVU18 Consul®) at (-20°C) and an ultra freezer (Ultra Freezer AL 374 - 80V American Lab®) at (-80°C) were used. After the teeth being submitted to the action of cold and heat for 7 and 30 days, the color, surface roughness and microhardness final readings were performed. For the heat evaluation, the color change (&Delta;E*, &Delta;L*, &Delta;a* e &Delta;b*) of the two aesthetic materials, and the surface roughness and microhardness of the three restorative materials, were subjected to statistical analysis (One-way ANOVA, Tukey, p<.05), with one variation factor, the temperature. For the cold evaluation, the data were statistically analyzed using 2-way ANOVA, Bonferroni, (p>.05) with two variation factors, time and temperature. Color alteration occurred for the aesthetic materials submitted to heat and cold. In the composite resin, the surface roughness and microhardness did not change (p>.05), regardless of temperature to which they were exposed. In CIV, the surface roughness and microhardness increased with the heat. After cold submission, there were no significant changes (p>.05) to these properties. For the amalgam, there was roughness change (p<.05) when submitted to heat at 300°C; the microhardness did not change. There were no significant changes in amalgam roughness or microhardness when teeth were submitted to cold (p>.05). It was concluded that the aesthetic materials can be distinguished by the color analysis, from 200°C to 300°C and when submitted to (-80°C), both after 7 days and 30 days. The freezing time is not significant for the distinction of materials. Roughness and microhardness tests can distinguish the aesthetic materials, regardless of the action of heat or cold.
37

Estudo das propriedades físicas e mecânicas de materiais restauradores odontológicos submetidos a condições de inumação e afogamento para fins periciais / Study of physical and mechanical properties of dental restorative materials subjected to conditions of inhumation and drowning for forensic purposes

Vicente, Sergio Augusto de Freitas 12 January 2015 (has links)
O objetivo deste estudo foi avaliar o efeito da simulação de condições de inumação e afogamento sobre estabilidade de cor, rugosidade de superfície e microdureza de resina composta (RC), cimento de ionômero de vidro (CIV) e amálgama de prata (AM), visando fornecer elementos para diferenciação de materiais estéticos e estimativa do tempo de submissão aos agentes. Foram obtidos 60 incisivos bovinos, que receberam preparos cavitários (6 x 6 mm e 2 mm de profundidade) e foram restaurados com RC FiltekMR Z250 XT (3M ESPE®), CIV KetacTM Fil Plus (3M ESPE®) e AM em cápsulas gs-80 (SDI®). Realizaram-se as primeiras leituras, que se constituíram no baseline, de: cor, (Espectrofotômetro VITA® Easyshade), rugosidade de superfície (Rugosímetro Mitutoyo® Surftest SJ-201P) e microdureza Knoop (microdurômetro Shimadzu® Micro Hardness Tester HMV-2). Em seguida, as amostras foram separadas em dois grupos de 30 (n=10), de acordo com as condições a que foram submetidas: simulação de condições de inumação e de afogamento, por 1, 3 e 6 meses, após os quais novas leituras foram realizadas. Os valores de alteração de cor (&Delta;E, &Delta;L, &Delta;a e &Delta;b) e demais propriedades dos materiais estéticos foram submetidos a análise estatística 3-way ANOVA, medidas repetidas, Bonferroni (p<0,05). Para o amálgama, foram comparados rugosidade superficial e microdureza (2-way ANOVA, medidas repetidas, Bonferroni, p<0,05). Verificou-se que condições de inumação e de afogamento produzem alteração de cor nos materiais restauradores estéticos, que não é tempo dependente. Não houve diferença (p>0,05) na microdureza dos materiais restauradores estéticos em função dos agentes e tempos testados, apesar de apresentarem diferenças inerentes quanto a essa propriedade. Houve alteração significativa (p<0,05) na microdureza do AM, após 6 meses de afogamento. Quanto à rugosidade de superfície, não houve diferença significante (p>0,05) para nenhum dos materiais, agentes e tempos testados. Concluiu-se que a contribuição desses métodos à identificação humana após inumação ou afogamento só é possível considerando-se a microdureza, sendo auxiliada pela análise da alteração de cor do material. Não é possível predizer o tempo de inumação ou afogamento de um indivíduo apenas com base nos parâmetros estudados / The purpose of this study was to evaluate the effect of simulated drowning and burial conditions on color stability, surface roughness and microhardness of composite resin (RC), glass ionomer cement (CIV) and silver amalgam (AM), aiming to provide elements for differentiation of aesthetic materials and estimation of the time of the agents have been subjected to these conditions. 60 bovine incisors were prepared with a 6 x 6 x 2mm cavity and were restored with RC FiltekMR XT Z250 (3M ESPE®), CIV KetacTM Fil (3M ESPE®) and AM capsules gs-80 (SDI®). The color, surface roughness and microhardness baselines were measured using a reflectance spectrophotometer with CIE L*a*b* system (VITA® Easyshade), a surface roughness device (Mitutoyo® Surftest SJ-201P) and a micro hardness tester (Shimadzu® HMV-2). Then, the samples were separated into two groups of 30 (n=10), in accordance with the conditions that they were subjected: simulation of burial and drowning conditions, for 1, 3 and 6 months, after which further measurements were performed. Values of &Delta;E, &Delta;L, &Delta;a e &Delta;b and the other properties of the aesthetic materials were statistically analyzed using 3-way ANOVA, repeated measures, Bonferroni (p<.05). For the amalgam, only surface roughness and microhardness were compared (2-way ANOVA, repeated measures, Bonferroni, p<.05). It was found that burial and drowning conditions produce color change in the aesthetic restorative materials, which is not time dependent. There was no difference (p>.05) in microhardness of aesthetic restorative materials caused by the agents and times tested, notwithstanding they have inherent differences regarding this property. There was significant change (p<.05) in AM microhardness after 6 months of drowning. Regarding surface roughness, there was no significant difference (p>.05) for any material, agents and times tested. It was concluded that the contribution of these methods to human identification after burial or drowning is only possible considering the hardness, being aided by the analysis of the color change of the material. It is not possible to predict the time of burial or drowning of an individual based solely on the studied parameters
38

Estudo das propriedades físicas e mecânicas de materiais restauradores odontológicos submetidos a condições de inumação e afogamento para fins periciais / Study of physical and mechanical properties of dental restorative materials subjected to conditions of inhumation and drowning for forensic purposes

Sergio Augusto de Freitas Vicente 12 January 2015 (has links)
O objetivo deste estudo foi avaliar o efeito da simulação de condições de inumação e afogamento sobre estabilidade de cor, rugosidade de superfície e microdureza de resina composta (RC), cimento de ionômero de vidro (CIV) e amálgama de prata (AM), visando fornecer elementos para diferenciação de materiais estéticos e estimativa do tempo de submissão aos agentes. Foram obtidos 60 incisivos bovinos, que receberam preparos cavitários (6 x 6 mm e 2 mm de profundidade) e foram restaurados com RC FiltekMR Z250 XT (3M ESPE®), CIV KetacTM Fil Plus (3M ESPE®) e AM em cápsulas gs-80 (SDI®). Realizaram-se as primeiras leituras, que se constituíram no baseline, de: cor, (Espectrofotômetro VITA® Easyshade), rugosidade de superfície (Rugosímetro Mitutoyo® Surftest SJ-201P) e microdureza Knoop (microdurômetro Shimadzu® Micro Hardness Tester HMV-2). Em seguida, as amostras foram separadas em dois grupos de 30 (n=10), de acordo com as condições a que foram submetidas: simulação de condições de inumação e de afogamento, por 1, 3 e 6 meses, após os quais novas leituras foram realizadas. Os valores de alteração de cor (&Delta;E, &Delta;L, &Delta;a e &Delta;b) e demais propriedades dos materiais estéticos foram submetidos a análise estatística 3-way ANOVA, medidas repetidas, Bonferroni (p<0,05). Para o amálgama, foram comparados rugosidade superficial e microdureza (2-way ANOVA, medidas repetidas, Bonferroni, p<0,05). Verificou-se que condições de inumação e de afogamento produzem alteração de cor nos materiais restauradores estéticos, que não é tempo dependente. Não houve diferença (p>0,05) na microdureza dos materiais restauradores estéticos em função dos agentes e tempos testados, apesar de apresentarem diferenças inerentes quanto a essa propriedade. Houve alteração significativa (p<0,05) na microdureza do AM, após 6 meses de afogamento. Quanto à rugosidade de superfície, não houve diferença significante (p>0,05) para nenhum dos materiais, agentes e tempos testados. Concluiu-se que a contribuição desses métodos à identificação humana após inumação ou afogamento só é possível considerando-se a microdureza, sendo auxiliada pela análise da alteração de cor do material. Não é possível predizer o tempo de inumação ou afogamento de um indivíduo apenas com base nos parâmetros estudados / The purpose of this study was to evaluate the effect of simulated drowning and burial conditions on color stability, surface roughness and microhardness of composite resin (RC), glass ionomer cement (CIV) and silver amalgam (AM), aiming to provide elements for differentiation of aesthetic materials and estimation of the time of the agents have been subjected to these conditions. 60 bovine incisors were prepared with a 6 x 6 x 2mm cavity and were restored with RC FiltekMR XT Z250 (3M ESPE®), CIV KetacTM Fil (3M ESPE®) and AM capsules gs-80 (SDI®). The color, surface roughness and microhardness baselines were measured using a reflectance spectrophotometer with CIE L*a*b* system (VITA® Easyshade), a surface roughness device (Mitutoyo® Surftest SJ-201P) and a micro hardness tester (Shimadzu® HMV-2). Then, the samples were separated into two groups of 30 (n=10), in accordance with the conditions that they were subjected: simulation of burial and drowning conditions, for 1, 3 and 6 months, after which further measurements were performed. Values of &Delta;E, &Delta;L, &Delta;a e &Delta;b and the other properties of the aesthetic materials were statistically analyzed using 3-way ANOVA, repeated measures, Bonferroni (p<.05). For the amalgam, only surface roughness and microhardness were compared (2-way ANOVA, repeated measures, Bonferroni, p<.05). It was found that burial and drowning conditions produce color change in the aesthetic restorative materials, which is not time dependent. There was no difference (p>.05) in microhardness of aesthetic restorative materials caused by the agents and times tested, notwithstanding they have inherent differences regarding this property. There was significant change (p<.05) in AM microhardness after 6 months of drowning. Regarding surface roughness, there was no significant difference (p>.05) for any material, agents and times tested. It was concluded that the contribution of these methods to human identification after burial or drowning is only possible considering the hardness, being aided by the analysis of the color change of the material. It is not possible to predict the time of burial or drowning of an individual based solely on the studied parameters
39

Análise das propriedades físicas e mecânicas de materiais restauradores odontológicos submetidos à ação do calor e do frio para fins periciais / Analysis of physical and mechanical properties of dental restorative materials subjected to the action of heat and cold for forensic purposes

Roberto Cesar Biancalana 03 June 2015 (has links)
O objetivo deste trabalho foi avaliar o efeito da ação do calor e do frio sobre a estabilidade de cor, rugosidade de superfície e microdureza de restaurações de resina composta (FiltekMR Z250 XT 3M ESPE®), cimento de ionômero de vidro (KetacTM Fil Plus 3M ESPE®) e amálgama de prata em cápsulas (gs-80 SDI®), na tentativa de simular o comportamento desses materiais, quando presentes nos elementos dentais de vítimas carbonizadas ou mortas por congelamento. Foram selecionados 180 dentes bovinos que foram preparados (6 X 6 mm com 2 mm de profundidade) e separados em grupos de 30 dentes, segundo o tipo de material restaurador utilizado. Em seguida, foram realizadas as leituras iniciais de cor (Espectrofotômetro VITA® Easyshade), rugosidade de superfície (Rugosímetro Mitutoyo® Surftest SJ-201P) e microdureza Knoop (Microdurômetro Shimadzu® Micro Hardness Tester HMV-2), que foram consideradas os padrões iniciais. Subsequentemente, os dentes foram separados aleatoriamente em grupos (n=10) segundo a temperatura utilizada para simulação de congelamento (-80°C), (-20°C) e 2,5°C; e carbonização (100°C, 200°C e 300°C). A submissão a altas temperaturas foi realizada pela colocação dos dentes restaurados em forno (ALUMINI Sinter-Press EDG®), pelo período de 15 minutos, e as baixas temperaturas foram realizadas em refrigerador (RFGE 700 GE®) a 2,5°C; congelador (CVU18 Consul®) a (-20°C) e freezer (Ultra Freezer AL 374 - 80V American Lab®) a (-80°C). Após 7 e 30 dias de ação do frio e da submissão ao calor, os dentes foram submetidos às leituras finais de cor, rugosidade e microdureza. No calor, os valores de alteração de cor (&Delta;E*, &Delta;L*, &Delta;a* e &Delta;b*), dos dois materiais estéticos, rugosidade superficial e microdureza dos três materiais restauradores, foram submetidos à análise estatística One-way ANOVA, Tukey (p<0,05), tendo como fator de variação, a temperatura. No frio, os dados foram submetidos à análise estatística 2-way ANOVA, Bonferroni (p<0,05), tendo como fatores de variação, o tempo e a temperatura. Verificou-se que houve alteração de cor dos materiais estéticos, tanto nas submissões ao calor quanto ao frio. Na resina composta, a rugosidade de superfície e a microdureza não se alteraram significantemente (p>0,05), independente da temperatura a que foram submetidos. No CIV, a rugosidade e a microdureza elevaram-se nos testes ao calor; e ao frio, não ocorreram alterações significativas (p>0,05) dessas propriedades. Para o amálgama houve alteração de rugosidade significante (p<0,05) no calor, nas submissões a 300°C; e a microdureza não se modificou. Ao frio não ocorreram mudanças significantes (p>0,05) na rugosidade nem na microdureza do amálgama. Concluiu-se que os materiais estéticos podem ser distinguidos, pela análise de cor, a partir de 200°C até 300°C e quando submetidos a (-80°C), tanto em 7 dias como em 30 dias. O tempo de congelamento não é significativo para a distinção dos materiais. Testes de rugosidade e microdureza podem distinguir os materiais estéticos, independentemente, da ação do calor ou do frio. / The purpose of this study was to evaluate the effect of the action of heat and cold on color stability, surface roughness and microhardness of composite resin (FiltekMR Z250 XT 3M ESPE®), glass ionomer cement (KetacTM Fil Plus 3M ESPE®) and silver amalgam capsules (gs-80 SDI®) restorations, in an attempt to simulate the behavior of these materials when present in dental elements of carbonized or killed by freezing victims. 180 bovine teeth were selected, prepared with a 6 x 6 mm 2 mm cavity and then separated into groups of 30 teeth, according to the type of restorative material. Then, initial color readings (Spectrophotometer VITA® Easyshade), surface roughness (Rugosimeter Mitutoyo® Surftest SJ-201P) and Knoop microhardness (Shimadzu Micro Hardness tester® HMV-2) readings were performed, which were considered the initial standards. Afterwards, the teeth were randomly divided into groups (n=10) according to the temperature used for freezing simulation (-80°C), (-20°C), (2,5°C); and carbonization simulation (100°C, 200°C, 300°C). Submission to high temperatures was performed by placing the restored teeth in an oven (ALUMINI Sinter Press EDG®), for 15 minutes and for low temperatures, a refrigerator (RFGE 700 GE®) at 2,5°C, a freezer (CVU18 Consul®) at (-20°C) and an ultra freezer (Ultra Freezer AL 374 - 80V American Lab®) at (-80°C) were used. After the teeth being submitted to the action of cold and heat for 7 and 30 days, the color, surface roughness and microhardness final readings were performed. For the heat evaluation, the color change (&Delta;E*, &Delta;L*, &Delta;a* e &Delta;b*) of the two aesthetic materials, and the surface roughness and microhardness of the three restorative materials, were subjected to statistical analysis (One-way ANOVA, Tukey, p<.05), with one variation factor, the temperature. For the cold evaluation, the data were statistically analyzed using 2-way ANOVA, Bonferroni, (p>.05) with two variation factors, time and temperature. Color alteration occurred for the aesthetic materials submitted to heat and cold. In the composite resin, the surface roughness and microhardness did not change (p>.05), regardless of temperature to which they were exposed. In CIV, the surface roughness and microhardness increased with the heat. After cold submission, there were no significant changes (p>.05) to these properties. For the amalgam, there was roughness change (p<.05) when submitted to heat at 300°C; the microhardness did not change. There were no significant changes in amalgam roughness or microhardness when teeth were submitted to cold (p>.05). It was concluded that the aesthetic materials can be distinguished by the color analysis, from 200°C to 300°C and when submitted to (-80°C), both after 7 days and 30 days. The freezing time is not significant for the distinction of materials. Roughness and microhardness tests can distinguish the aesthetic materials, regardless of the action of heat or cold.

Page generated in 0.2736 seconds