• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 483
  • 9
  • 6
  • 6
  • 6
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 510
  • 510
  • 510
  • 185
  • 181
  • 149
  • 131
  • 114
  • 104
  • 101
  • 98
  • 87
  • 78
  • 77
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
421

Maximização da margem de estabilidade sujeito a minimização do custo de produção da energia eletrica utilizando formulação em dois niveis / Maximization of the stability margin subjected to electric power generation cos minimization using a bilevel programming approach.

Aria Arias, David 29 August 2008 (has links)
Orientadores: Carlos Alberto de Castro Junior, Alexandre de Assis Mota / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T20:26:47Z (GMT). No. of bitstreams: 1 AriaArias_David_M.pdf: 982619 bytes, checksum: 902edfe03a42ce4e64a22f698a4267cf (MD5) Previous issue date: 2008 / Resumo: O presente trabalho apresenta um modelo para o planejamento da operação de sistemas de potência visando maximizar a margem de estabilidade de tensão ao mesmo tempo em que minimizam-se os custos da produção da energia (despacho econômico). O objetivo é obter uma solução para o planejamento da operação da rede que leve em conta não só aspectos técnicos, mas também econômicos. Para que esse objetivo possa ser atingido, esse problema é formulado como um problema da programação bilevel (BLPP) ou em dois níveis. O modelo bilevel permite definir funções objetivo distintas para maximizar a margem da estabilidade de tensão e, ao mesmo tempo, conseguir um despacho econômico ótimo, permitindo a imposição de diferentes restrições para as variáveis internas e externas do problema. Uma vez que o BLPP apresenta-se como um problema matemático complexo, ele é reduzido a um problema de otimização de um só nível (single-level), substituindo-se o problema de otimização interno pelas condições de ótimalidade de Karush-Kuhn-Tucker (KKT). Foram realizados testes e simulações em diferentes sistemas elétricos, sendo que os resultados obtidos atestam a validade da metodologia proposta. Além disso, a formulação e o método de solução do BLPP apresentados neste trabalho são mais simples que outros encontrados na literatura, tornando essa metodologia bastante flexível para a utilização e investigação de outras funções objetivo, variáveis e parâmetros de controle. / Abstract: This work presents a model for power systems operation planning that aims to maximize the voltage stability margin and also the economic dispatch. The objective is to obtain a solution for the network operation planning that takes into account both technical and economical aspects. In order to reach this goal, this problem is formulated as a bilevel programming problem (BLPP). The bilevel model allows to define distinct objective functions for maximizing the voltage stability margin looking, simultaneously, for an optimum economic dispatch, and permitting the imposition of different constraints to the variables of the inner and outer problems. Since the BLPP is a complex mathematical problem, it is reduced to a single-level optimization problem by replacing the inner optimization problem by its Karush-Kuhn-Tucker optimality conditions. Simulations and tests were carried out for different electric networks, and the results show that the proposed methodology is valid. Moreover, the BLPP formulation and its solution method are simpler than other formulations found in the literature, making the methodology very flexible to accommodate other objective functions, variables and control parameters. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
422

Desenvolvimento de uma metodologia para a coordenação hidrotérmica de longo prazo em mercado elétrico competitivo / DEVELOPMENT OF A METHODOLOGY FOR THE COORDINATION HYDROTHERMAL-TERM IN ELECTRIC MARKET COMPETITIVE

Paredes, Romel Wiliams Jimenez 26 February 2007 (has links)
Made available in DSpace on 2016-08-17T14:53:12Z (GMT). No. of bitstreams: 1 Romel Jimenez.pdf: 804071 bytes, checksum: 8f161d1f48519af0d6ee9068f4876a93 (MD5) Previous issue date: 2007-02-26 / In this work a methodology based on linear programming for long-term hydrothermal scheduling of electric power systems is proposed. The objective of the hydrothermal scheduling is to find an optimal operation for a specific time interval and with high reliability and minimum cost. That is equivalent to determine an optimal generation scheduling for the power plants and for each time interval considered, in order to the power system satisfies the forecasted demand. Linear models of the power system components are adopted, and with the option to solve systems with multiple reservoirs and buses. It was implemented a computer program using MATLAB platform for application to small test power systems and configurations of real-size systems such as the interconnected Peruvian System and the Brazilian South-Souheast System. For the solution of the linear optimization problem was used the interior points method. From the analysis of the test systems results is concluded that the linear model may capture adequately the relevant characteristics of the real power system and it may be eficient and precise such as the detailed model. / Neste trabalho é proposta uma metodologia baseada em programação linear para a solução da coordenação hidrotérmica de longo prazo de sistemas de energia elétrica. O objetivo da coordenação hidrotérmica é encontrar uma política de operação ótima em um determinado período de tempo, com alta confiabilidade e custo mínimo. Isto equivale a determinar um cronograma ótimo de geração para cada usina, a cada intervalo de tempo, de modo que o sistema atenda a demanda prevista. Adotam-se modelos lineares dos componentes do sistema de potência, com a opção de resolver sistemas com múltiplos reservatórios e múltiplas barras. Foi implementado um programa computacional em MATLAB para a solução de sistemas teste de pequeno porte e configurações de sistemas de potência reais tal como o Sistema Interligado Peruano e o Sistema Brasileiro da Bacia Sul-Sudeste. Para a solução do problema de otimização linear foi utilizado o método de pontos interiores. Da análise dos resultados com os sistemas teste conclui-se que o modelo linear pode capturar adequadamente as características relevantes do sistema real e pode ser tão eficiente e preciso quanto o modelo detalhado.
423

MÉTODOS ALTERNATIVOS PARA ESTIMAÇÃO DE ESTADO EM SISTEMAS DE ENERGIA ELÉTRICA / ALTERNATIVE METHODS FOR ESTIMATION OF STATE IN POWER SYSTEMS

Frazão, Rodrigo José Albuquerque 23 January 2012 (has links)
Made available in DSpace on 2016-08-17T14:53:18Z (GMT). No. of bitstreams: 1 Dissertacao Rodrigo Albuquerque.pdf: 3312916 bytes, checksum: c9ee0be229b62b8aafd7816c3400351d (MD5) Previous issue date: 2012-01-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The state estimation process applied to electric power systems aims to provide a trustworthy ―image‖, coherent and complete of the system operation, allowing an efficient monitoring. The state estimation is one of the most important functions of energy management systems. In this work, will be proposed alternative methods of state estimation for electric power systems in the levels of transmission, subtransmission and distribution. For transmission systems are proposed two hybrid methods considering the insertion of conventional measurements combined with phasor measurements based on phasor measurement unit (PMU). To estimate the state in subtransmission systems is proposed an alternative method which, in occurrence of failures in active and/or reactive meters in the substations, uses a load forecasting model based on criteria similar days and application of artificial neural networks. This process of load forecasting is used as a generator of pseudo measurements in state estimation problem, which takes place through the propagation of phasor measurements provided by a PMU placed in the boundary busbar. For the distribution system state estimation the proposed method uses the mathematical method of weighted least squares with equality constraints by modifying the set of measurements and the state variables. It is also proposed a methodology evaluation of the PMUs measurement channel availability for observability analysis. The application of the proposed methods to test systems shows that the results are satisfactory. / O processo de estimação de estado aplicado a sistemas elétricos de energia tem como objetivo fornecer uma imagem confiável, coerente e completa da operação do sistema, permitindo um monitoramento eficiente. A estimação de estado é uma das funções mais importantes dos sistemas de gerenciamento de energia. Neste trabalho são propostos métodos alternativos de estimação de estado para sistemas elétricos nos níveis de transmissão, subtransmissão e de distribuição. Para sistemas de transmissão são propostos dois métodos híbridos considerando a inserção das medições convencionais combinadas com medições fasoriais baseadas na unidade de medição fasorial (PMU - Phasor Measurement Unit). Para a estimação de estado em sistemas de subtransmissão é proposto um método alternativo que, na ocorrência de falhas nos medidores de potência ativa e/ou reativa das subestações, utiliza um modelo de previsão de carga baseado no critério de dias similares e na aplicação de redes neurais artificiais. Esse processo de previsão de carga é utilizado como gerador de pseudomedições na estimação de estado, que se dá através da propagação da medição fasorial fornecida por uma PMU alocada no barramento de fronteira. Para sistemas de distribuição o método de estimação de estado proposto consiste em aplicar o método de mínimos quadrados ponderados com restrições de igualdade, modificando-se o plano de medição e as variáveis de estado. Também é proposta uma metodologia para avaliação da disponibilidade dos canais de medições da PMU e o seu impacto na observabilidade do sistema. A aplicação dos métodos propostos a sistemas teste mostram que os resultados obtidos são satisfatórios.
424

Princípio do equivalente certo no planejamento da operação de sistemas hidrotérmicos / Certainty equivalence principle in long term hydrothermal scheduling

Silva, Thayze D'Martin Costa da, 1988- 25 August 2018 (has links)
Orientadores: Secundino Soares Filho, Mônica de Souza Zambelli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T07:16:16Z (GMT). No. of bitstreams: 1 Silva_ThayzeD'MartinCostada_M.pdf: 9346773 bytes, checksum: 73c504aef1611f22af50cead8deff7bf (MD5) Previous issue date: 2014 / Resumo: O Princípio do Equivalente Certo (PEC) garante que as abordagens determinística e estocástica são equivalentes na otimização de sistemas dinâmicos estocásticos quando satisfeitas certas condições. É possível que o problema de planejamento da operação energética (POE) se aproxime de satisfazer as condições do PEC, apesar de não atendê-las teoricamente. Assim, o objetivo desta dissertação é analisar a validade do PEC no âmbito da Programação Dinâmica aplicado ao POE de sistemas hidrotérmicos constituídos de um único reservatório e avaliar o impacto da violação de cada condição. As hipóteses do PEC foram analisadas progressivamente por meio da comparação dos resultados dos modelos considerados, desde o ideal que atende teoricamente às condições, até o mais próximo da realidade. Foram observadas diferenças pouco significativas entre as políticas de operação determinística e estocástica, indicando que o modelo de POE se aproxima de atender às condições do PEC. Uma consequência imediata deste estudo seria que a abordagem determinística do problema de POE para sistemas hidrotérmicos com um único reservatório pode ser tão eficaz quanto as abordagens estocásticas / Abstract: Certainty Equivalence Principle (CEP) ensures that deterministic and stochastic approaches are equivalent in stochastic dynamic systems optimization when some assumptions hold. It is possible that Long Term Hydrothermal Scheduling (LTHS) problem is close to attaining CEP¿s assumptions, although it does not attain them theoretically. Thus, the objective of this dissertation is to analyze the validity of CEP in Dynamic Programming framework applied to single reservoir LTHS problem and to evaluate the impacts of each CEP¿s condition violation. The CEP¿s conditions were progressive analyzed by comparison of the considered models results from an ideal case where theoretically assumptions hold until a case study closer to reality. Slight differences were observed between deterministic and stochastic operation policies, indicating that LTHS model is close to attain the CEP¿s conditions. An immediate consequence of this study would be that deterministic approach for the single reservoir LTHS problem can be as effective as stochastic ones / Mestrado / Energia Eletrica / Mestra em Engenharia Elétrica
425

Método da barreira modificada via reescalonamento não linear aplicado ao fluxo de potência reativa ótimo / Modified barrier method by nonlinear rescaling applied to optimal reactive power flow

Silva, Iara da Cunha Ribeiro da, 1983- 08 May 2013 (has links)
Orientador: Anésio dos Santos Júnior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-23T02:47:49Z (GMT). No. of bitstreams: 1 Silva_IaradaCunhaRibeiroda_D.pdf: 1773553 bytes, checksum: 06519e6714ec628c0365a39c3384366d (MD5) Previous issue date: 2013 / Resumo: Nesta tese é apresentado o método da barreira modificada via princípio de reescalonamento não linear aplicado ao fluxo de potência reativa ótimo. Esse método é baseado na transformação das restrições de desigualdade do fluxo de potência reativa ótimo, gerando um problema de barreira modificado. Resolvendo uma sequência desses problemas barreira modificado, o método pode alcançar a solução do fluxo de potência reativa ótimo. A estratégia de busca é composta por dois ciclos: o primeiro minimiza a função Lagrangeana associada ao problema de barreira modificada através do método de Newton e o segundo ciclo atualiza as variáveis duais do problema não linear. O método barreira modificado é aplicado em sistemas elétricos do IEEE e os resultados são apresentados na tese / Abstract: In this thesis is presented the modified barrier method, based on the nonlinear rescaling principle and applied to the problem for optimal reactive power flow. This method is based on the transformation of nonlinear inequality constraints of the optimal power flow that generates a modified barrier problem. On searching the solution of a sequence of these problems the method can achieve the solution of the optimal power flow. The search strategy is composed by two stages: the first one update the dual variable approximation of inequality constraints of the problem. The second one minimizes the Lagrangian function of the modified barrier problem by Newton's method. This strategy has been applied to optimal power flow IEEE systems and the results are also shown in this thesis / Doutorado / Energia Eletrica / Doutora em Engenharia Elétrica
426

Análise de novos sinais para a detecção de ilhamento de geradores síncronos distribuídos / New signals for anti-islanding protection of synchronous distributed generators

Delvecchi, Esloany Daisy Carniatto 07 August 2011 (has links)
Orientadores: Walmir de Freitas Filho, José Carlos de Melo Vieira Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T11:09:25Z (GMT). No. of bitstreams: 1 Delvecchi_EsloanyDaisyCarniatto_M.pdf: 1048681 bytes, checksum: 837e57f3ee3363dd7bb9f49a72408fe1 (MD5) Previous issue date: 2011 / Resumo: Geradores síncronos conectados em redes de distribuição de energia elétrica estão sujeitos a operarem de forma ilhada após a ocorrência de distúrbios na rede elétrica. Ilhamento ocorre quando uma parte da rede de distribuição torna-se eletricamente isolada da fonte de energia principal (subestação), mas continua a ser energizada por geradores distribuídos conectados no subsistema isolado. A prática atualmente utilizada pelas concessionárias e recomendada nos principais guias técnicos é desconectar todos os geradores tão logo ocorra um ilhamento. Tipicamente, é necessário detectar uma situação de ilhamento em menos de dois segundos, dependendo, principalmente, do tempo de operação dos religadores automáticos. Os métodos mais comuns e baratos para detectar ilhamento compreendem relés baseados em medidas de freqüência (sub/sobrefrequência, taxa de variação de frequência e "salto de vetor") e o relé de tensão. No entanto, esses relés podem falhar se os níveis de desbalanço de potência ativa e reativa no subsistema ilhado forem pequenos. Portanto, o objetivo dessa dissertação é investigar a potencialidade de novos sinais para detectar ilhamento de geradores síncronos distribuídos, como forma de substituição ou complementação aos dispositivos de proteção anti-ilhamento convencionais. Os sinais analisados neste trabalho são taxa de variação da potência ativa (dP/dt), a relação Volts por Hertz (V/Hz), a variação da impedância (Z) medida no ponto de acoplamento comum (PAC), e a diferença angular ('delta' 'teta') entre as tensões medidas no PAC e na subestação. A investigação é baseada no levantamento de um conjunto de curvas relacionando tempo de detecção e desbalanço de potência ativa/reativa e nas zonas de não detecção, as quais fornecem os pontos de operação para os quais o relé em estudo falha na detecção do ilhamento. As curvas e as zonas são obtidas através de simulações de transitórios eletromagnéticos trifásicas considerando diferentes perfis de carga-geração na rede ilhada. Os resultados obtidos mostram que os sinais analisados têm um grande potencial para esse tipo de aplicação, porém são sujeitos à atuação indevida no caso da ocorrência de eventos que não sejam ilhamentos na rede de distribuição. Assim, uma análise de falsa operação também é conduzida e são propostas melhorias para minimizar e/ou eliminar a atuação indevida desses relés aqui investigados / Abstract: Synchronous generators connected to distribution power networks are likely to operate islanded following faults clearance in the system. Islanding occurs when a portion of the distribution system becomes electrically isolated from the substation, yet it continues energized by distributed generators connected to the islanded system. Utilities and standards recommend the disconnection of distributed generators immediately after islanding occurrences, otherwise it can lead to a number of problems to the generator and the connected loads. Typically, it is required to detect an islanding situation faster than two seconds after the island formation, depending, mainly, on the operation time of automatic reclosers. The most common and economical methods to detect islanding include the relays based on measures of frequency (under/over frequency, rate of change of frequency and vector surge) and voltage. However, these relays can fail if the active and reactive power imbalance levels in the islanded system are small. Therefore, the objective of this thesis is to investigate the potentiality of new signals to detect islanding of distributed synchronous generators, as replacement or complement to conventional protection anti-islanding devices. The signals analyzed in this research are the rate of change of generator active power (dP/dt), the ratio Volts per Hertz (V/Hz), impedance variation (Z) measured at the point of common coupling (PCC), and the angular difference ('delta' 'teta') between the voltage angle measured at the PCC and at the utility substation. The investigation is based on a set of curves, which relate time of islanding detection and active/reactive power imbalance and on the nondetection zones, which provide the operating points for which the relay fails to detect the islanding. These are obtained through electromagnetic transient three-phase simulations considering different profiles of generation-load in the islanded network. The results show that the signals analyzed have a huge potential for this type of application, however, their performance can decrease in case of occurrence of non-islanding events in the distribution system. Thereby, an analysis of false operation is conducted in order to propose improvements to minimize and/or to eliminate improper behavior of these relays / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
427

Propostas para a construção da matriz de energia elétrica brasileira com foco na sustentabilidade do processo de expansão da oferta e segurança no suprimento da carga / Proposals for the construction of the Brazilian electric power matrix with focus on the sustainability of the expansion process and the security of supply

Dester, Mauricio 21 August 2018 (has links)
Orientadores: Sérgio Valdir Bajay, Moacyr Trindade de Oliveira Andrade / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-21T11:31:07Z (GMT). No. of bitstreams: 1 Dester_Mauricio_D.pdf: 5389676 bytes, checksum: 7c5e6ad30bbd780ddf1b9300f7cc4317 (MD5) Previous issue date: 2012 / Resumo: A eletricidade é bem de consumo e também insumo posicionado dentre aqueles considerados essenciais para a sociedade moderna. Neste contexto, o planejamento e a construção de uma matriz de energia elétrica é questão de importância capital não somente para o setor elétrico, como também para o desenvolvimento do Brasil. A constituição desta matriz deve ser pautada, sobretudo, pelo aspecto sustentabilidade. Neste sentido, sua concepção deve, imprescindivelmente, contemplar todas as perspectivas que permeiam o processo estratégico que a origina, a saber: técnica, econômica e sócio-ambiental. Somente balizado por estas óticas é possível proporcionar a expansão da oferta de energia elétrica de forma sustentável e com segurança no que concerne ao atendimento pleno da demanda, um requisito indispensável para que este serviço possa ser um sólido sustentáculo de um processo maior: o desenvolvimento socioeconômico da sociedade brasileira. A participação das fontes renováveis na matriz de energia elétrica é fator desejável e colabora, de forma meritória no que diz respeito aos impactos ambientais decorrentes da produção de eletricidade. Todavia, há algumas questões de ordem econômica e principalmente técnica as quais devem ser tratadas e lapidadas de forma a eliminar as lacunas existentes, permitindo que se possa estabelecer planos de expansão da oferta de eletricidade sustentáveis sob todos os pontos de vista. O objetivo principal deste trabalho é proporcionar e aprofundar o debate sobre estas questões e apresentar uma solução que propicie a integração das fontes renováveis na matriz de energia elétrica brasileira mantendo a confiabilidade no atendimento da carga. Outrossim, não somente os aspectos técnico e econômico foram contemplados na análise, mas, também o socioambiental, possibilitando assim oferecer subsídios para a evolução da oferta com orientação para a sustentabilidade. Para elaboração da proposta foi realizado um estudo abrangente sobre as principais fontes primárias a partir das quais é possível produzir eletricidade, além de uma revisão de todo o extenso e complexo caminho pelo qual passou o setor de planejamento da expansão desde seus primórdios até o modelo atual. São também apresentados vários pontos de vista sobre as dificuldades encontradas pelo planejador, desde os empecilhos de ordem regulatória, passando por aqueles oriundos de uma falta de coordenação dentre os setores do governo envolvidos no problema, até as questões de ordem ambiental. Por fim, no decorrer do trabalho e particularmente ao concluí-lo, propõe-se um conjunto de medidas estratégicas por intermédio das quais se pode construir uma matriz de energia elétrica segura e sustentável e lograr êxito, sob as perspectivas técnica, econômica e socioambiental, ao se realizar o planejamento da expansão da oferta, seja no horizonte de curto, médio ou longo prazos / Abstract: Electricity is not just a consumer good but also an input which commands a place amongst those goods considered essential to modern society. In this context, the planning and construction of an electricity matrix is a question of paramount importance, not just for the electricity sector but also for Brazil's development as a whole. The establishment of this matrix should, above all, be regulated with an emphasis on sustainability. In this regard, its conception must necessarily embrace all the perspectives that imbue the strategic process that gives rise to it: technical, economic and socio-environmental. Delimited by these viewpoints alone, it is possible to provide the sustainable expansion of an electric power supply that is also secure in terms of being able to fully meet demand. This is a fundamental prerequisite to this service becoming a solid base for a larger process, namely the socio-economic development of Brazilian society. The participation of renewable energy sources in the electric energy matrix is a desirable factor and contributes laudably to the mitigation of environmental impacts resulting from the electricity generation. Nevertheless, there are several issues of an economic and mainly technical nature which have to be dealt with and refined in order to close the existing gaps and enable plans to be established, that are sustainable from all points of view, for the expansion of an electric power supply. The main aim of this study is to prompt, and study in greater depth, the debate over these issues and present a solution that delivers the integration of renewable sources into Brazil's electricity matrix while maintaining reliability of load fulfillment. Similarly, not only were the technical and economic aspects covered in the analysis but also the socio-environmental aspects, thereby making it possible to provide support for the evolution of a sustainability-oriented supply. For the purposes of drafting this proposal, a wide-ranging study was conducted of the principal primary sources from which it is possible to generate electricity, as well as a review of the long and complex path which the expansion planning sector has taken, from its outset through to the current model. Various points of view are also put forward about the difficulties encountered by the planner, ranging from the regulatory obstacles to those arising from a lack of coordination between the government sectors involved in the problem and to issues of an environmental nature. Finally, throughout the study and in particular in its conclusion, a set of strategic measures is proposed through which a secure, sustainable electricity matrix can be constructed from a technical, economic and socio-environmental perspective, which is successful in carrying out supply expansion planning in the short, medium and long term / Doutorado / Planejamento de Sistemas Energeticos / Doutor em Planejamento de Sistemas Energéticos
428

Um modelo de despacho e pré-despacho de retaivas através de algoritmos genéticos, fluxo de potência ótimo e busca tabu = A model of reactive dispatch and a model of short-term reactive operation planning through geneti algorithms, optimal power flow and search tabu / A model of reactive dispatch and a model of short-term reactive operation planning through geneti algorithms, optimal power flow and search tabu

Modesto, Sonia Angelina Garcia 21 August 2018 (has links)
Orientador: Takaaki Ohishi / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T16:39:20Z (GMT). No. of bitstreams: 1 Modesto_SoniaAngelinaGarcia_D.pdf: 7966542 bytes, checksum: e394ce8619b189ec96e83326835c45df (MD5) Previous issue date: 2003 / Resumo: Esta tese trata do problema de planejamento da operação de curto prazo (operação diária) de reativos. A Cadeia de Planejamento do Setor Elétrico brasileiro inicia com um Planejamento de Longo Prazo, o qual considera a operação do sistema através de modelos equivalentes em um horizonte de cinco anos. Em seguida o Planejamento de Médio Prazo, utilizando um modelo individualizado para cada usina hidrelétrica e termelétrica, analisa a operação para um horizonte de um ano à frente. A próxima etapa é de Programação da Operação, a qual determina a operação do sistema para o horizonte de alguns dias à frente. Finalmente, a solução da Programação da Operação é utilizada pela operação em tempo real como uma referência operativa. Em todas estas etapas, as modelagens representam apenas a geração e transmissão de potência ativa (Modelo DC). Para a parte reativa não há planejamento. Neste estudo sobre a parte reativa, enfocou-se o aspecto das variáveis discretas, mais precisamente os taps dos transformadores. Supõe-se conhecido um despacho de geração ativa, dado pela Programação da Operação, e um despacho de potência reativa, obtido por exemplo através de um caso base, ou através de um modelo de fluxo de potência ótimo reativo. Inicialmente foi estudado o problema de despacho de reativos, o qual considera o operação em um dado instante de tempo (problema estático). Para este problema, foram desenvolvidos três abordagens. A primeira é uma metodologia híbrida combinando Algoritmos Genéticos (AG) e um modelo de Fluxo de Potência Ótimo (FPO). Nesta abordagem as variáveis discretas são tratadas através dos AG e cada indivíduo é avaliado através de um FPO. A vantagem desta metodologia é que esta determina conjuntamente as variáveis continuas (geração de potência ativa e reativa) e as variáveis discretas; a desvantagem é o elevado tempo computacional. Buscando diminuir o tempo de processamento, foram desenvolvidos duas outras metodologias, uma utilizando um método de Busca Local e a outra baseada em Busca Tabu. Em ambas as metodologias, o FPO foi substituído por um modelo de fluxo de potência não linear. O plano de operação reativa ao longo de um dia, aqui denominado prédespacho de reativos, visa estimar uma solução em termos do posicionamento dos taps para cada intervalo do dia, buscando obter um perfil de tensão mais adequado do ponto de vista operativo. A abordagem para o pré-despacho de reativos utiliza o modelo de despacho de reativos baseado em Busca Tabu, mas considera a solução obtida no intervalo anterior. Todas as metodologias utilizaram o sistema IEEE30 como sistema teste / Abstract: This thesis treats the short-term (daily operation) reactive operation planning. The Brazilian operation planning initially performs a long-term operation study. This planning uses a equivalent model representation and take into account a time horizon of five years. The next step is the mid operation planning, that uses a individual representation and considers one year operation. The last planning determines the short-term operation using a more detailed model, including transmission operation constraints through a linear model. Finally, this short-term planning is used as operational guidelines in the real time operation. The models used in these different planning represent only the active power generation and transmission. For reactive operation there are not planning. This study about reactive operation focused the discrete decision. More specifically, the taps are treated as discrete variables. The methodologies supposes that the active and reactive power generations are given. Initially, the reactive dispatch problem is treated, and three methodologies are developed. The first is a hybrid model, that combines a Genetic Algorithm approach with an Optimal Power Flow model. This methodology has the advantage to determine the active and reactive generations and discrete variables values; the inconvenient is the high computer time processing. Two others methodologies are developed in order to obtain more faster approach. One approach is based on Local Search and the other is based on Tabu Search. In both methodologies, the OPF model is substituted by a non-linear power flow. The proposed daily reactive operation planning aims to determines the taps position for each time interval, looking for a more operationally suitable voltage profile. This planning is based on the Tabu Search Reactive Dispatch model. All methodologies used the IEEE30 as test system / Doutorado / Automação / Doutora em Engenharia Elétrica
429

Algoritmos para o planejamento da operação de sistemas modernos de distribuição de energia elétrica = Algorithms for operation planning of modern electric distribution power systems / Algorithms for operation planning of modern electric distribution power systems

Araujo, Ricardo Augusto de, 1982- 08 July 2012 (has links)
Orientador: Madson Cortes de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T03:46:06Z (GMT). No. of bitstreams: 1 Araujo_RicardoAugustode_M.pdf: 1212312 bytes, checksum: 401c38dac32e9784866225fb23096b21 (MD5) Previous issue date: 2012 / Resumo: O problema do planejamento da operação de redes de distribuição de energia elétrica consiste em determinar os ajustes para os taps dos transformadores e reguladores de tensão, para os bancos de capacitores e para as injeções de potências ativas e reativas dos geradores distribuídos e da subestação, obedecendo aos limites físicos e operacionais da rede, a fim de melhorar o seu desempenho. Este pode ser formulado como um problema de Fluxo de Potência Ótimo (FPO) bastante complexo, pois envolve fatores técnicos, como a regulação de tensão em regime permanente, e econômicos, como a redução de perdas e a valoração da energia fornecida por produtores independentes. Este trabalho propõe dois algoritmos para resolver o problema de planejamento da operação. No primeiro, é usado um algoritmo genético similar ao desenvolvido por Chu e Beasley, somado a um esquema especial de criação da população inicial. Este algoritmo pode prover soluções de boa qualidade e até mesmo a solução ótima global do problema. O segundo algoritmo é baseado na análise de sensibilidades e é capaz de encontrar soluções de boa qualidade a um custo computacional bastante inferior ao custo do algoritmo genético proposto. Além de poder ser aplicado no planejamento de curto-prazo da operação de modernas redes de distribuição de energia elétrica, os métodos propostos podem, por exemplo, auxiliar as concessionárias de energia elétrica na definição de condições para o estabelecimento de contratos com produtores independentes de energia. Os resultados apresentados, baseados nos sistemas de distribuição radiais de 34, 70 e 135 barras, mostram que os algoritmos propostos são promissores / Abstract: The distribution system operation planning stage is concerned with the determination of capacitor bank, transformer and voltage regulator settings. This must be accomplished considering active and reactive power injections of distributed generators and at the main substation, as well as physical and regulatory issues in order to improve the network performance. This is a quite complex Optimal Power Flow (OPF) problem because it involves technical factors such as steady state voltage regulation, economic factors such as losses reduction and energy bids from independent power producers. This work proposes two approaches to solve this operation planning problem. The first one uses a genetic algorithm similar to that developed by Chu and Beasley, however with a different strategy to create the initial population. This algorithm can provide good quality solutions and in some cases even optimal solutions. The second one is based on the use of sensitivities, where good quality solutions are obtained at low computing times, much lower than those obtained using the proposed genetic algorithm. Besides being applicable in short-term operation planning of distribution networks, the proposed methods could also assist the utility operator in setting up conditions for establishing contracts with independent power producers. The results presented here using radial distribution systems of 34, 70 and 135 buses demonstrated the potential of the proposed algorithms / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
430

Um modelo de espaço de estados com representação de segunda ordem para a analise das oscilações de modo interarea em sistemas de energia eletrica / A space state model including second order representation for the analysis of power systems inter-area mode oscillations

Domingues, Adriana Favaro 18 March 2005 (has links)
Orientador : Vivaldo Fernando da Costa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-04T02:42:32Z (GMT). No. of bitstreams: 1 Domingues_AdrianaFavaro_D.pdf: 789245 bytes, checksum: 9ca2b124a01cd871aa7f4bbb4c63c57a (MD5) Previous issue date: 2005 / Resumo: Este trabalho aborda o problema das oscilações eletromecânicas de baixa freqüência de modo interárea em sistemas de energia elétrica através de duas metodologias: primeiramente, através do método convencional da análise modal linear e, posteriormente, através da aplicação do método da forma normal dos campos vetoriais como ferramenta para viabilizar o acréscimo dos termos não lineares de segunda ordem resultantes da expansão em série de Taylor. Neste caso, o método da forma normal é aplicado a um Modelo de Sensibilidade de Potência com representação de segunda ordem, para investigar os efeitos das interações não lineares entre os modos naturais de oscilação de sistemas de energia elétrica. São consideradas, em ambas as análises, a inclusão de dispositivos FACTS e da modelagem dinâmica das cargas. As simulações são realizadas para um sistema simétrico de duas áreas e para o Sistema Equivalente Sul-Sudeste Brasileiro. A metodologia de análise proposta mostra-se bastante satisfatória como alternativa à simulação não linear no domínio do tempo e à análise modal convencional / Abstract: In this work, the analysis of power systems inter-area mode oscillations is performed by the application of two different methodologies: first, the linear modal analysis, and then the analysis including second order nonlinear terms from a Taylor series expansion, with the application of the method of normal forms of vector fields. In this case, the method of normal forms is applied to a Power Sensitivity Model including second order nonlinear terms, in order to investigate the effects of nonlinear interactions between system modes. Both methodologies consider the inclusion of FACTS devices and dynamic load model. Simulations are performed for a symmetric two-area test power system and for the Equivalent South-Southeast Brazilian system. The results obtained show that the methodology proposed is very effective as an alternative to linear modal analysis and timedomain simulation in the performance of inter-area mode oscillations analysis / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica

Page generated in 0.053 seconds