31 |
Identifying the optimum storage capacity for a 100-MWe concentrating solar power plant in South AfricaMadaly, Kamalahasen 04 1900 (has links)
Thesis (MEng)--Stellenbosch University, 2014. / ENGLISH ABSTRACT: Central receiver power plants generate renewable electricity by exploiting the
energy provided by the sun. The conditions experienced in the Northern Cape
region of South Africa provide the ideal conditions for the development of these
plants. Without a storage medium these plants have capacity factors in the range
of 25-30%. The inclusion of a thermal energy storage medium provides the ability
to increase the capacity factors of these plants. Although storage increases the
costs, it results in better utilisation of the power block and a decrease in the
levelised electricity cost (LEC). Eskom intends building a 100MWe central
receiver dry cooled power plant in the Upington region. This research identifies
the appropriate storage medium and ideal storage capacity to achieve the lowest
LEC.
A literature survey was performed to identify the different methods of storage that
are available. The different storage methods were evaluated and the best storage
medium for a central receiver power plant based on the developments of the
various storage technologies was identified.
To determine the costs associated with a central receiver power plant, data
published by NREL was used. Different plant parameters were required to
evaluate the costs. A power plant model based on efficiencies and energy balances
was created to determine the required plant parameters. It provided the ability to
determine the effect of changing different plant parameters on the LEC and
estimate the plant output. The power block parameters were initially varied to
determine the most efficient power block configuration. Once the most efficient
power block configuration was identified the solar field and storage parameters
were varied to determine the plant configuration which resulted in the lowest
LEC.
The most efficient power block configuration of 0.4206 was found for a system
comprising of six feedwater heaters with the feedwater temperature of 230°C,
main steam pressure 140 bar and an exit steam generator salt temperature of
290°C. A solar multiple of 3.0 with 16 hours of storage resulted in a LEC of
R1.41/kWh with no system constraints. A capacity factor constraint of 60%
resulted in a solar multiple of 1.8 with 8 hours of storage and a LEC of
R1.78/kWh. / AFRIKAANSE OPSOMMING: Sonkragaanlegte met sentrale ontvangers wek hernubare elektrisiteit op deur
sonenergie te ontgin. Die klimaat in die Noord Kaap-streek van Suid-Afrika is
ideaal vir die oprigting van hierdie aanlegte. Sonder ’n bergingsmedium is die
kapasiteitsfaktore van sulke aanlegte ongeveer 25-30%. Met die insluiting van ’n
bergingsmedium vir termiese energie kan die kapasiteitsfaktore egter verhoog
word. Hoewel berging aanlegkoste verhoog, lei dit terselfdertyd tot beter
aanwending van die kragblok en ’n afname in die konstante eenheidskoste van
elektrisiteit (LEC). Eskom beplan om ’n droogverkoelde kragaanleg van 100 MW
met ’n sentrale ontvanger in die Upington-streek op te rig. Hierdie navorsing was
dus daarop toegespits om die mees geskikte bergingsmedium en ideale
bergingskapasiteit te bepaal om die laagste moontlike LEC uit die aanleg te
verkry.
’n Literatuurstudie is onderneem om die verskeie beskikbare bergingsmetodes te
bestudeer. Die verskillende metodes is beoordeel, waarna die beste
bergingsmedium vir ’n kragaanleg met ’n sentrale ontvanger op grond van die
ontwikkelings in die verskillende bergingstegnologieë bepaal is.
Om die koste van ’n kragaanleg met ’n sentrale ontvanger te bepaal, is
gepubliseerde data van die Amerikaanse Nasionale Laboratorium vir Hernubare
Energie (NREL) gebruik. Verskillende aanlegparameters was egter nodig om die
koste te beoordeel. Dié parameters is gevolglik bepaal deur ’n kragaanlegmodel
op grond van doeltreffendheidsfaktore en energiebalanse te skep. Sodoende kon
vasgestel word watter uitwerking veranderinge in die verskillende parameters op
die LEC sou hê, en kon die aanleguitset geraam word. Die kragblokparameters is
aanvanklik afgewissel om die doeltreffendste kragbloksamestel te bepaal. Nadat
dít bepaal is, is die sonenergieveld en bergingsparameters weer afgewissel om vas
te stel watter aanlegsamestel die laagste LEC tot gevolg sou hê. Die beste termiese benuttingsgraad is behaal vir ʼn stoom siklus met ses water
verhitters en ʼn water temperatuur van 230 °C by die ketel se inlaat, ʼn stoom druk
van 140 bar, en sout uitlaat temperatuur van 290 °C. ʼn Vermenigvuldigingsfaktor
van drie vir die heliostaat veld, en 16 uur termiese energie storing gee ʼn
opwekkingskoste van R 1.41/kW/h indien daar geen beperkings op die grootte of
koste van die stelsel geplaas word nie. Indien die kapitaal uitgawe ʼn perk van
60 % op die kapasitiet van die stelsel plaas, verander die optimale ontwerpspunt
na ʼn vermenigvuldigingsfaktor van 1.8, en die termiese stoorkapasitiet verlaag na
8 uur. In hierdie geval is die opwekkingskoste R 1.78/kWh.
|
32 |
Production optimale d’énergie pour une communauté à petite échelle : application à l’optimisation d’une centrale solaire hybride produisant électricité et chaleur / Optimal energy delivery at a small community scale : application to the optimization of a hybrid solar power plant producing electricity and heatMabrouk, Mohamed Tahar 05 November 2015 (has links)
Ce travail traite la modélisation et l'optimisation des centrales solaires thermodynamiques à concentration produisant de l'électricité pour l'électrification des zones rurales isolées et mal raccordées au réseau électrique. D’abord, un modèle optique et thermique détaillé des concentrateurs solaires cylindro-paraboliques est présenté permettant l'identification de capteurs existants et la création de corrélations qui peuvent être injectées dans un modèle plus global. Dans un second temps, un modèle original d'un stock de chaleur stratifié de type « lit de roche » est développé. Le nouveau modèle proposé permet de déterminer analytiquement le profil de température dans le stock à n'importe quel instant dans le cas d'une température d'entrée régulée. Ensuite, deux alternatives de bloc moteur sont modélisées : le moteur Stirling et le Cycle Organique de Rankine (ORC acronyme anglais pour Organic Rankine Cycle). Concernant le moteur Stirling, une revue critique des modèles existants a été effectuée. Certains de ces modèles ont été implémentés et complétés par des modèles originaux des pertes par fuite de matière et par effet navette. Le cycle organique de Rankine, lui, est modélisé par un modèle orientée vers l'optimisation. Enfin, une optimisation mono et multicritère d’une centrale solaire est effectuée. La configuration étudiée est équipée d’un stock de chaleur et d’une chaudière d’appoint. Elle est optimisée selon trois critères : le coût moyen actualisé de l'électricité (LCOE acronyme anglais pour Levelized Cost Of Electricity), le rendement énergétique de la centrale et la quantité de CO2 émise par Kilowatt heure d'électricité produite / This work deals with the modelling and the optimization of thermodynamic solar power plants intended to supply electricity to isolated locations. Firstly, a state of the art of solar collectors is achieved and a model for parabolic trough collectors is proposed. This model is used for actual collectors identification. It is used also to propose correlations to be introduced in the whole system model. In a second time, a state of the art of energy storage technologies is conducted and an original model of a packed bed storage tank is proposed. This model gives an explicit solution of the temperature inside the tank without using a time step based numerical resolution. Two alternatives for the power block are given: Stirling engines and Organic Rankine Cycles. For Stirling engines, a critical review of existing models is performed. Some losses occurring in Stirling engines are not well documented in the literature as leakage losses at the power piston and displacer gap losses. Therefore, original models are proposed to estimate these losses. When compared to former models in the literature, the new model of the displacer gap losses demonstrates clearly that it is very important to use decoupled models with caution. Concerning the ORC, an optimization-oriented model is proposed. Finally, a mono and multi-objective optimization of a solar power plant is performed. The optimized system is composed of a solar field, a packed bed heat storage, a power block and an auxiliary fired heater. Objective functions used in this study are: the Levelized Cost of Electricity (LCOE), the energetic efficiency of the power plant and CO2 emission per kilowatt hour of electricity
|
33 |
Hodnocení investičního záměru / The Evaluation of the the Investment ProjectČech, Květoslav January 2012 (has links)
The aim of this diploma thesis is to evaluate the economic efficiency of investment based on particular investment project of solar power plant through various economics methods. The basic economics methods of investment efficiency, among these methods can be found static methods as well as dynamic ones that respect the time factor. Among the most important indicator evaluating investment efficiency belongs net present value, internal rate of return and pay-off period. Last but not least, the possible risks connected with the implementation of the investment and their impacts on total efficiency are identified and preventive precautions are recommended.
|
34 |
A hierarchical model for photovoltaic system performance analysisMarathe, Hemant Yeshwant January 1985 (has links)
The advent of new technology and ever-escalating fuel prices would make alternative energy sources increasingly important in coming years. This study is aimed to develop the tools required to analyze the feasibility of alternate energy sources. Although the study refers specifically to solar energy, the methodology is good for any alternative energy source.
Four models are used to analyze complete performance of a photovoltaic(PV) system. The SOLAR model estimates the total radiation at a site. The PVPM model calculates the PV output for this total radiation. The PRODCOST and LIFECC models analyze the economic performance of the photovoltaic system.
This works as a complete package which by itself will help to make preliminary analysis of various sites before making a further in-depth study for a selected few. The model is intended to be a part of a larger model, which will be a complete planning tool for power system expansion in developing countries. The efforts towards this direction can be continued further by developing various models, each analyzing a special task. The models can be integrated to form a hierarchical structure which completely models the power system in developing countries. / M.S.
|
35 |
Optimization and control of a large-scale solar chimney power plantPretorius, Johannes Petrus 03 1900 (has links)
Thesis (PhD (Mechanical and Mechatronic Engineering))-- University of Stellenbosch, 2007. / ENGLISH ABSTRACT: The dissertation builds on previous research (Pretorius, 2004) and investigates the optimization and control of a large-scale solar chimney power plant. Performance results are based on a reference location near Sishen in South Africa and a so-called reference solar chimney power plant, with a 5000 m collector diameter and a 1000 m high, 210 m diameter chimney. The numerical simulation model is refined and used to perform a sensitivity analysis on the most prominent operating and technical plant specifications. Thermo-economically optimal plant configurations are established from simulation results and calculations according
to an approximate plant cost model. The effects of ambient wind, temperature lapse
rates and nocturnal temperature inversions on plant performance are examined. Various
new technologies are investigated for the purpose of controlling plant output according to specific demand patterns. The incorporation of vegetation under the collector roof of the plant and the influence thereof on plant performance is also explored. Results indicate that, through the modification of the collector roof reflectance, collector roof emissivity, ground surface absorptivity or ground surface emissivity, major improvements
on plant performance are possible. Introducing thermal insulation or double glazing of the collector roof also facilitates substantial enhancements on plant yield. Simulations predict a notable sensitivity to the ground surface absorptivity value, while variable atmospheric temperature lapse rates and windy ambient conditions may impair plant performance significantly. Furthermore, sand is found to be unsuitable as plant ground type and thermoeconomically optimal solar chimney plant dimensions are determined to be generally larger than plant dimensions employed in previous studies. Good dynamic control of solar chimney power output is established, suggesting that a solar chimney power plant can be implemented as a base or peak load electricity generating facility. Lastly, results predict that vegetation,
when provided with sufficient water, will be able to survive under the collector roof but the inclusion of vegetation will however cause major reductions in plant performance. / AFRIKAANSE OPSOMMING: Die proefskrif bou op vorige navorsing (Pretorius, 2004) en ondersoek die optimering
en beheer van 'n grootskaalse sonskoorsteen-kragstasie. Uitsetresultate word baseer op 'n
verwysingsligging naby Sishen in Suid-Afrika en 'n sogenaamde verwysingskragstasie, met 'n
kollektor deursnee van 5000 m en 'n 1000 m hoë, 210 m deursnee skoorsteen. Die numeriese
rekenaarmodel is verbeter en gebruik vir die uitvoering van 'n sensitiwiteits-analise op die
belangrikste bedryfs- en tegniese kragstasie spesifikasies. Termo-ekonomiese optimale
aanlegkonfigurasies is bepaal volgens die uitsetresultate van die rekenaarmodel en benaderde
aanleg-kosteberekeninge volgens 'n eenvoudige kostemodel. Die invloed van wind, atmosferiese
temperatuur gradiënte en nagtelike temperatuur inversies op kragstasie uitset word
beskou. Verskeie nuwe tegnologië word ondersoek met die doel om aanleg uitset te kan
beheer volgens spesifieke elektrisiteit aanvraagspatrone. Die inkorporasie van plantegroei
onder die kollektordak, en die invloed daarvan op kragstasie uitset, word ook beskou.
Bevindings dui aan dat, deur die wysiging van die kollektordak refleksie, kollektordak
emissiwiteit, grondoppervlak absorptiwiteit of grondoppervlak emissiwiteit, groot verbeterings
op aanleg uitset moontlik is. Die implementering van termiese isolasie of 'n dubbelglaslaag
vir die kollektordak veroorsaak ook 'n beduidende verheffing in kragstasie uitset.
Simulasies voorspel 'n merkbare sensitiwiteit teenoor die grondoppervlak absorptiwiteitswaarde,
terwyl veranderlike atmosferiese temperatuur daaltempos en winderige omgewingstoestande
aanleg uitset beduidend mag belemmer. Verder is bevind dat sand ongeskik is as
aanleg grond tipe en dat termo-ekonomiese optimale sonskoorsteen-kragstasie dimensies in
die algemeen groter is as die aanvaarde aanlegdimensies van vorige studies. Goeie dinamiese beheer van sonskoorsteen-kragstasie uitset is bevestig, wat suggereer dat die sonskoorsteenkragstasie as 'n basis of pieklas elektrisiteitopwekkings-aanleg ingespan kan word. Ten laaste voorspel resultate dat plantegroei, mits dit voorsien word van genoegsame water, sal kan oorleef onder die kollektordak maar dat die inkorporasie van plantegroei die aanleg uitset
beduidend sal benadeel. / Sponsored by the Centre for Renewable and Sustainable Energy Studies
|
36 |
Thermal energy storage in metallic phase change materialsKotze, Johannes Paulus 12 1900 (has links)
Thesis (PhD) -- Stellenbosch University, 2014. / ENGLISH ABSTRACT: Currently the reduction of the levelised cost of electricity (LCOE) is the main goal of concentrating solar power (CSP) research. Central to a cost reduction strategy proposed by the American Department of Energy is the use of advanced power cycles like supercritical steam Rankine cycles to increase the efficiency of the CSP plant. A supercritical steam cycle requires source temperatures in excess of 620°C, which is above the maximum storage temperature of the current two-tank molten nitrate salt storage, which stores thermal energy at 565°C. Metallic phase change materials (PCM) can store thermal energy at higher temperatures, and do not have the drawbacks of salt based PCMs. A thermal energy storage (TES) concept is developed that uses both metallic PCMs and liquid metal heat transfer fluids (HTF). The concept was proposed in two iterations, one where steam is generated directly from the PCM – direct steam generation (DSG), and another where a separate liquid metal/water heat exchanger is used – indirect steam generation, (ISG). Eutectic aluminium-silicon alloy (AlSi12) was selected as the ideal metallic PCM for research, and eutectic sodium-potassium alloy (NaK) as the most suitable heat transfer fluid.
Thermal energy storage in PCMs results in moving boundary heat transfer problems, which has design implications. The heat transfer analysis of the heat transfer surfaces is significantly simplified if quasi-steady state heat transfer analysis can be assumed, and this is true if the Stefan condition is met. To validate the simplifying assumptions and to prove the concept, a prototype heat storage unit was built. During testing, it was shown that the simplifying assumptions are valid, and that the prototype worked, validating the concept. Unfortunately unexpected corrosion issues limited the experimental work, but highlighted an important aspect of metallic PCM TES. Liquid aluminium based alloys are highly corrosive to most materials and this is a topic for future investigation.
To demonstrate the practicality of the concept and to come to terms with the control strategy of both proposed concepts, a storage unit was designed for a 100 MW power plant with 15 hours of thermal storage. Only AlSi12 was used in the design, limiting the power cycle to a subcritical power block. This demonstrated some practicalities about the concept and shed some light on control issues regarding the DSG concept. A techno-economic evaluation of metallic PCM storage concluded that metallic PCMs can be used in conjunction with liquid metal heat transfer fluids to achieve high temperature storage and it should be economically viable if the corrosion issues of aluminium alloys can be resolved. The use of advanced power cycles, metallic PCM storage and liquid metal heat transfer is only merited if significant reduction in LCOE in the whole plant is achieved and only forms part of the solution. Cascading of multiple PCMs across a range of temperatures is required to minimize entropy generation. Two-tank molten salt storage can also be used in conjunction with cascaded metallic PCM storage to minimize cost, but this also needs further investigation. / AFRIKAANSE OPSOMMING: Tans is die minimering van die gemiddelde leeftydkoste van elektrisiteit (GLVE) die hoofdoel van gekonsentreerde son-energie navorsing. In die kosteverminderingsplan wat voorgestel is deur die Amerikaanse Departement van Energie, word die gebruik van gevorderde kragsiklusse aanbeveel. 'n Superkritiese stoom-siklus vereis bron temperature hoër as 620 °C, wat bo die 565 °C maksimum stoor temperatuur van die huidige twee-tenk gesmelte nitraatsout termiese energiestoor (TES) is. Metaal fase veranderingsmateriale (FVMe) kan termiese energie stoor by hoër temperature, en het nie die nadele van soutgebaseerde FVMe nie. ʼn TES konsep word ontwikkel wat gebruik maak van metaal FVM en vloeibare metaal warmteoordrag vloeistof. Die konsep is voorgestel in twee iterasies; een waar stoom direk gegenereer word uit die FVM (direkte stoomopwekking (DSO)), en 'n ander waar 'n afsonderlike vloeibare metaal/water warmteruiler gebruik word (indirekte stoomopwekking (ISO)). Eutektiese aluminium-silikon allooi (AlSi12) is gekies as die mees geskikte metaal FVM vir navorsingsdoeleindes, en eutektiese natrium – kalium allooi (NaK) as die mees geskikte warmteoordrag vloeistof.
Termiese energie stoor in FVMe lei tot bewegende grens warmteoordrag berekeninge, wat ontwerps-implikasies het. Die warmteoordrag ontleding van die warmteruilers word aansienlik vereenvoudig indien kwasi-bestendige toestand warmteoordrag ontledings gebruik kan word en dit is geldig indien daar aan die Stefan toestand voldoen word. Om vereenvoudigende aannames te bevestig en om die konsep te bewys is 'n prototipe warmte stoor eenheid gebou. Gedurende toetse is daar bewys dat die vereenvoudigende aannames geldig is, dat die prototipe werk en dien as ʼn bevestiging van die konsep. Ongelukkig het onverwagte korrosie die eksperimentele werk kortgeknip, maar dit het klem op 'n belangrike aspek van metaal FVM TES geplaas. Vloeibare aluminium allooie is hoogs korrosief en dit is 'n onderwerp vir toekomstige navorsing.
Om die praktiese uitvoerbaarheid van die konsep te demonstreer en om die beheerstrategie van beide voorgestelde konsepte te bevestig is 'n stoor-eenheid ontwerp vir 'n 100 MW kragstasie met 15 uur van 'n TES. Slegs AlSi12 is gebruik in die ontwerp, wat die kragsiklus beperk het tot 'n subkritiese stoomsiklus. Dit het praktiese aspekte van die konsep onderteken, en beheerkwessies rakende die DSO konsep in die kollig geplaas. In 'n tegno-ekonomiese analise van metaal FVM TES word die gevolgtrekking gemaak dat metaal FVMe gebruik kan word in samewerking met 'n vloeibare metaal warmteoordrag vloeistof om hoë temperatuur stoor moontlik te maak en dat dit ekonomies lewensvatbaar is indien die korrosie kwessies van aluminium allooi opgelos kan word. Die gebruik van gevorderde kragsiklusse, metaal FVM stoor en vloeibare metaal warmteoordrag word net geregverdig indien beduidende vermindering in GLVE van die hele kragsentrale bereik is, en dit vorm slegs 'n deel van die oplossing. ʼn Kaskade van verskeie FVMe oor 'n reeks van temperature word vereis om entropie generasie te minimeer. Twee-tenk gesmelte soutstoor kan ook gebruik word in samewerking met kaskade metaal FVM stoor om koste te verminder, maar dit moet ook verder ondersoek word.
|
37 |
Modélisation et caractérisation expérimentale d’une boucle solaire cylindro-parabolique intégrant un stockage de type thermocline / Modeling and experimental characterization of a parabolic trough solar loop integrating a thermocline energy storage systemFasquelle, Thomas 10 November 2017 (has links)
Comme les autres technologies liées aux énergies renouvelables, le solaire à concentration souffre des problèmes liés à l’intermittence de la ressource. La technologie thermocline est une solution prometteuse qui réduirait le coût du stockage thermique dans les centrales solaires de ce type. Cependant, aucune étude n’a jusqu’ici porté sur l’impact de la variation de la température en sortie du réservoir de stockage de type thermocline sur les autres composants de la centrale. Ce travail de thèse a pour but d’améliorer les connaissances sur ce sujet, grâce à l’utilisation d’une mini boucle solaire cylindro parabolique intégrant un stockage thermocline.En premier lieu, la compatibilité entre le fluide de transfert de la centrale (huile synthétique) et les potentiels matériaux de garnissage de la cuve de stockage (Cofalit, briques de cendres volantes, alumine) est vérifiée. Puis les performances de chacun des composants de la centrale (cuve de stockage, collecteurs solaires, générateur de vapeur) sont analysées expérimentalement et numériquement. Enfin, le comportement du système global est étudié, avec un accent porté sur l’impact de la variation de la température de sortie de la cuve thermocline sur les autres composants.Il a été montré qu’avec un dimensionnement et une stratégie de contrôle appropriés, la technologie thermocline diminue très peu les performances de la centrale solaire par rapport à la technologie conventionnelle à deux cuves (maximum 3 4 % de diminution de la production électrique). / Like other renewable energy technologies, concentrated solar power (CSP) suffers from resource intermittence. Thermocline technology is a promising solution to decrease cost of thermal energy storage in CSP plants. Thermocline behavior has thoroughly been studied in the past years and its behavior is considered well known. However no study treated of thermocline tanks integrated in CSP plants. Thus, the impact of the varying outlet temperature of the thermocline storage has not been assessed yet. This work aims to fill this lack of knowledge by studying a mini parabolic trough power plant integrating a thermocline tank as storage.First, the compatibility between the heat transfer fluid of the plant (synthetic oil) and various potential filler materials (Cofalit, coal fly ash bricks, alumina) of the storage tank is verified. Then, some performance studies are performed on the three main components of the power plant (energy storage tank, solar collectors, steam generator). Finally, the behavior of the whole system is assessed, with a focus on the impact of the varying fluid temperature at the outlet of the thermocline tank on the other components.It has been shown that, with a proper sizing and an appropriate control strategy, thermocline technology induces very low decrease of the solar power plant performance in comparison to the conventional two tank technology (maximum 3-4% of electrical power production difference).
|
38 |
Probabilistic solar power forecasting using partially linear additive quantile regression models: an application to South African dataMpfumali, Phathutshedzo 18 May 2019 (has links)
MSc (Statistics) / Department of Statistics / This study discusses an application of partially linear additive quantile regression
models in predicting medium-term global solar irradiance using data
from Tellerie radiometric station in South Africa for the period August 2009
to April 2010. Variables are selected using a least absolute shrinkage and
selection operator (Lasso) via hierarchical interactions and the parameters
of the developed models are estimated using the Barrodale and Roberts's
algorithm. The best models are selected based on the Akaike information
criterion (AIC), Bayesian information criterion (BIC), adjusted R squared
(AdjR2) and generalised cross validation (GCV). The accuracy of the forecasts
is evaluated using mean absolute error (MAE) and root mean square
errors (RMSE). To improve the accuracy of forecasts, a convex forecast combination
algorithm where the average loss su ered by the models is based
on the pinball loss function is used. A second forecast combination method
which is quantile regression averaging (QRA) is also used. The best set
of forecasts is selected based on the prediction interval coverage probability
(PICP), prediction interval normalised average width (PINAW) and prediction
interval normalised average deviation (PINAD). The results show that
QRA is the best model since it produces robust prediction intervals than
other models. The percentage improvement is calculated and the results
demonstrate that QRA model over GAM with interactions yields a small
improvement whereas QRA over a convex forecast combination model yields
a higher percentage improvement. A major contribution of this dissertation
is the inclusion of a non-linear trend variable and the extension of forecast
combination models to include the QRA. / NRF
|
39 |
A Study on Applying Learning Techniques to Remote Sensing DataRadhakrishnan, Aswathnarayan 06 October 2020 (has links)
No description available.
|
40 |
Materials and thermal storage systems by sensible heat for thermodynamic electro-solar plants / Matériaux et systèmes de stockage thermique en chaleur sensible pour centrales électro-solaires thermodynamiquesNahhas, Tamar 27 October 2017 (has links)
L'énergie solaire est connue pour sa nature intermittente par rapport aux ressources d’énergie fossile. Cette observation souligne la nécessité d'utilisation d’un système de stockage d'énergie thermique. Le système de stockage thermocline est considéré comme un système de stockage rentable. La présente thèse vise à étudier le potentiel des roches basaltiques et siliceuses comme des candidates matériaux de stockage pour les centrales solaires concentrées. Les études expérimentales des propriétés thermo-physiques et thermomécaniques de ces roches à des températures allant jusqu'à 1000°C montrent que ces roches offrent de bonnes propriétés thermiques par rapport aux matériaux classiques de stockage. L'analyse du système de stockage thermocline sur un lit de roches à air direct est réalisée par une approche numérique. En outre, cette recherche vise également à évaluer l’impact environnementale de ce type de système de stockage en effectuant une analyse comparative de son cycle de vie. Enfin, une étude complémentaire réalisée dans le but de produire une carte d'indice de pertinence a permis d’identifier les zones les plus appropriées pour la construction des centrales solaires en Egypte. L'originalité de cette approche alternative pour le stockage d'énergie thermique est qu’elle combine la performance et la disponibilité des matériaux de stockage tout en réduisant leurs impacts environnementaux et financiers. / Compare to fossil fuel energy resources, solar energy is known for its intermittent nature. This observation highlights the need for the use of a thermal energy storage system. The thermocline storage system is considered as a cost-effective storage system. This thesis aims to study the potential of basalt and silex rocks as candidate storage materials for concentrated solar power plants. Experimental studies of the thermo-physical and thermo-mechanical properties of these rocks at temperatures up to 1000°C show that these rocks offer good thermal properties compared with conventional storage materials. The analysis of the thermocline storage system of air rock-packed bed is carried out using a numerical approach. This research also aims to assess the environmental impact of this type of storage system by conducting a comparative analysis of its life cycle. Finally, a complementary study carried out with the aim of producing a relevance index map made it possible to identify the most suitable areas for the construction of solar power plants in Egypt. The originality of this alternative approach for thermal energy storage is that it combines the performance and availability of storage materials while reducing their environmental and financial impacts.
|
Page generated in 0.0254 seconds