• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 80
  • 68
  • 25
  • 6
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 372
  • 372
  • 97
  • 85
  • 73
  • 61
  • 58
  • 51
  • 41
  • 37
  • 33
  • 33
  • 31
  • 30
  • 30
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Shear stress distribution within narrowly constrained structured grains and granulated powder beds

Antony, S.J., Al-Sharabi, M., Rahmanian, Nejat, Barakat, T. 22 October 2015 (has links)
Yes / An experimental study is presented here to understand the stress transmission characteristics under different geometrical arrangements of particulates inside a narrow chamber subjected to axial compression loading. The multi-grain systems considered here are face-centred, simple cubic and poly-dispersed structures, as well as inclusions embedded inside seeded, unseeded and cohesive powder bed of Durcal (calcium carbonate). The distribution of the maximum shear stress, direction of the major principal stress and shear stress concentration factor were obtained using photo stress analysis tomography (PSAT). The results show that the maximum shear stress distribution in the simple cubic structure is chain-like and self-repetitive, i.e., a single grain behaviour is representative of the whole system. This is not the case in the case of other granular packing. In the case of the inclusion surrounded by powder media, the maximum shear stress distribution in the inclusion occurs through ring-like structures, which are different from those observed in the structured granular packing. This tendency increases for an increase in the cohesivity of the surrounding particulates. In the granular systems, the direction of the major principal stress is mostly orthogonal to the direction of loading except in some particles in the random granular packing. In the case of inclusion surrounded by Durcal particulates, the directional of the major principal stress acts along the direction of the axial loading except in the ring region where this tends to be oblique to the direction of axial loading. Estimates of the shear stress concentration factor (k) show that, k tends to be independent of the structural arrangement of granular packing at higher load levels. In the case of inclusion surrounded by powder bed, k for the seeded granulated particulate bed is mostly independent of the external load levels. In the case of unseeded particulate (granulated) bed, a fluctuation in k is observed with the loading level. This suggests that the seeded granules could distribute stresses in a stable manner without much change in the nature of shear stress-transmitting fabric of the particulate contacts under external loading. An increase in the cohesion of particulate bed results in more plastic deformation as shown by the differential shear stress concentration factor. The results reported in this study show the usefulness of optical stress analysis to shed some scientific lights on unravelling some of the complexities of particulate systems under different structural arrangements of grains and surrounding conditions of the inclusions in particulate media.
202

Mechanism investigation on weathered mudstone slope deformation under excavation process with geological complexity and folded structure / 複雑な地質と褶曲構造を有する風化泥岩の斜面掘削過程における変形メカニズムの解明

Yuan, Kaixuan 25 March 2024 (has links)
京都大学 / 新制・課程博士 / 博士(工学) / 甲第25262号 / 工博第5221号 / 京都大学大学院工学研究科都市社会工学専攻 / (主査)教授 岸田 潔, 教授 安原 英明, 准教授 橋本 涼太 / 学位規則第4条第1項該当 / Doctor of Philosophy (Engineering) / Kyoto University / DFAM
203

Stress Analysis of Ramberg-Osgood and Hollomon 1-D Axial Rods

Giardina, Ronald J, Jr 17 May 2013 (has links)
In this paper we present novel analytic and finite element solutions to 1-D straight rods made of Ramberg-Osgood and Hollomon type materials. These material models are studied because they are a more accurate representation of the material properties of certain metals used often in manufacturing than the simpler composite linear types of stress/strain models. Here, various types of loads are considered and solutions are compared against some linear models. It is shown that the nonlinear models do have manageable solutions, which produce important differences in the results - attributes which suggest that these models should take a more prominent place in engineering analysis.
204

Análise da distribuição das tensões em maxila submetida à expansão cirurgicamente assistida com aparelho ósseo-suportado / Analysis of the distribution of maxillary stresses submitted to surgically assisted maxillary expansion with a bone-supported device

Tieghi Neto, Victor 22 June 2017 (has links)
A expansão de maxila cirurgicamente assistida (EMCA) é a modalidade de tratamento que tem como objetivo romper as regiões de reforço maxilar permitindo seu movimento expansivo gradativamente. Tal movimento pode ser realizado às custas de aparelhos dento-suportado, dento-muco-suportado, implanto-suportados ou ósseo-suportado. Os efeitos produzidos pelo tratamento vão desde alterações esqueléticas (aumento da base, cavidade e do espaço aéreo nasais) até inclinações dentárias (principalmente nos dentes de suporte do aparelho expansor), dentre outras. O objetivo desta pesquisa foi avaliar, por meio do Método de Elementos Finitos (MEF), a distribuição das tensões produzidas pela EMCA nas estruturas maxilares utilizando-se aparelho expansor ósseo-suportado. Material e métodos: Foi confeccionado um modelo tridimensional de maxila para simulação da EMCA com osteotomia tipo LeFort I descendente sem degrau, com disjunção pterigomaxilar utilizando um modelo de aparelho ósseo-suportado para o teste com a simulação de abertura de 1mm. Os resultados mostraram maior abertura da maxila na região anterior de incisivos a pré-molar (1 mm) e em menor quantidade (0,6mm) na região de molares. A tensão máxima principal (TMXP) mostrou a concentração de tensões principalmente em toda face palatina da maxila de pré-molar ao túber maxilar. Pela face lateral, ficou mais evidente a TMXP nas região de osso alveolar posterior ao pré-molar, molares e túber, assim como na região de pilar zigomático acima da osteotomia. Pelo plano transversal foi possível observar a transmissão de tensões ao longo das estruturas ósseas mostrando pouca dissipação para as raízes do molar. Enquanto que as forças de compressão (Tensão Mínima Principal), evidenciadas pela tensão mínima principal, se manifestaram nas áreas de pilar zigomático e adjacentes as osteotomias, assim como na áreas de contato do apoio do aparelho com o osso palatino. Tensões de tração e compressão também foram evidenciadas na região de processo pterigoide. A análise de tensão de Von Mises mostrou que a parte que mais sofre estresse é a haste que liga o módulo do aparelho com a plataforma de apoio. Conclusão: Houve maior abertura da maxila na região anterior e as tensões resultantes de forças transmitidas ao osso alveolar dos dentes adjacentes ao aparelho, parecem não ser suficientes para deslocar os dentes. / Surgically assisted maxillary expansion (SARME) is the modality of treatment that aims to weaken the points of maxillary reinforcement allowing its gradual expansion. Such movement can be performed at the expense of dento-supported, dento-muco-supported, implanto-supported or bony-backed devices. The effects produced by the treatment range from skeletal changes (increase of nasal base, cavity and nasal air space) to dental inclinations (mainly in the supporting teeth of the expander apparatus), among others. The objective of the present research was to evaluate the distribution of stress produced by SARME in the maxillary structures using the bone-supported expander apparatus by the Finite Element Method (FEM). Material and methods: A three-dimensional hemi-maxilla model was simulated for SARME with a non-step descending LeFort I osteotomy with pterygomaxillary disjunction using a bone-supported device model for the 1mm aperture simulation test. The results showed a greater opening of the maxilla in the anterior region of the incisors to the premolar (1 mm) and smaller (0.6 mm) in the molar region. The principal maximal stress (TMXP) showed the concentration of the tension forces mainly in all the palatine face of the pre-molar maxilla to the maxillary tuft. Due to the lateral aspect, the TMXP was more evident in the posterior alveolar bone region, the molars and tuber, as well as in the epilating zygomatic region above the osteotomy. From the transversal plane, it was possible to observe the transmission of stress along the bony structures showing little dissipation for the roots of the molar. Meanwhile, the forces of compression (Principal Minimum Tension) evidenced by the principal minimal stress, were manifested in the areas of the zygomatic pillar adjacent to the osteotomies, as well as in the areas of contact of the support of the apparatus with the palatine bone. Tension and compression forces were also evidenced in the pterygoid process region. Von Mises\' stress analysis showed that the most stressed part is the rod connecting the device module to the support platform. Conclusion: There was a greater opening of the maxilla in the anterior region and the resulting forces of tension transmitted to the alveolar bone of the teeth adjacent to the appliance did not seem to be sufficient to displace the teeth.
205

Comparação da eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares: uma análise de elementos finitos tridimensional / Efficiency comparison in stress distribution of different post types: a 3D finite element analysis

Mayer-Santos, Eric Mayer dos 03 November 2016 (has links)
Elementos dentais endodonticamente tratados geralmente necessitam de retentores intrarradiculares para prover retenção e suporte ao processo restaurador. O objetivo deste estudo foi comparar a eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares, através do método dos elementos finitos. Um modelo tridimensional de elementos finitos foi desenvolvido para representar um incisivo central superior endodonticamente tratado e restaurado com uma coroa total cerâmica, e quatro tipos diferentes de pinos pré-fabricados (dois convencionais, e dois modelos customizados) foram inseridos sob esse modelo e comparados quanto à distribuição das tensões às quais foram submetidos. Os quatro pinos diferem em formato e material de composição. O primeiro é um pino pré-fabricado metálico customizado referente à uma patente, com porção coronária anatômica (com curvaturas e formatos semelhantes à coroa anatômica) e flange rosqueável. O segundo pino pré-fabricado é semelhante em formato ao primeiro pino, mas será composto por fibra de vidro. O terceiro é um pino metálico pré-fabricado convencional, sem presença de flange. O quarto pino é semelhante ao terceiro pino em formato, mas será composto por fibra de vidro. Foi aplicada sobre os modelos uma mesma força estática média de 100 N com uma angulação de 135 graus ao longo eixo do dente no centro da face palatina do modelo, com o objetivo de simular a carga mastigatória e obter a distribuição das tensões. A avaliação apresentou os resultados considerando os critérios de Von Mises e tensões máximas principais. Os resultados mostraram que os pinos metálicos customizados resultaram em menores tensões à dentina e à estrutura coronária quando comparados aos pinos convencionais, e que ambos os pinos metálicos apresentaram menores tensões à estrutura coronária se comparados aos pinos em fibra de vidro. Em relação à estrutura dentinária, os pinos metálicos e os pinos em fibra de vidro apresentaram resultados semelhantes quanto à distribuição de tensões. Os modelos em fibra de vidro apresentaram resultados semelhantes em ambas as avaliações. Conclui-se que os modelos customizados foram superiores aos convencionais quando compostos pela liga metálica, mas semelhantes quando compostos por fibra de vidro. / Endodontically treated teeth commonly require a post to provide retention and support to the restorative process. The aim of this study was to compare the efficiency of the distribution stresses of different models of posts through the finite element method. A three-dimensional finite element model was developed to represent an endodontically treated maxillary central incisor restored with a ceramic crown, and four different types of prefabricated posts (two conventional and two customized models) have been inserted in that model and compared regarding the distribution of the stresses to which they were subjected. The four posts differ in size and material composition. The first is a custom metal prefabricated post relating to a patent, with anatomical coronal portion (with curvatures and format similar to the anatomical crown) and threaded flange. The second prefabricated post is similar in format to the first post, but is composed of fiberglass. The third is a conventional prefabricated metal post without the flange. The fourth post is similar to the third in format, but is composed of fiberglass. It was applied on the models the same average static occlusal force of 100N with an angle of 135 degrees to the tooth long axis in the palatal surface of the crown, with an objective of simulate the masticatory load and obtain the stress distribution. The evaluation presented the results considering the Von Mises and Maximum principal stress criteria. The results showed that the customized metal posts resulted in lower stresses to dentin and coronal tooth structure when compared to conventional posts, and both metallic posts had lower stresses in the coronal portion structure compared to glass fiber posts. Regarding the dentinal structure, metal posts and fiberglass posts showed similar results of stresses. The fiberglass models showed similar results in both evaluations. We conclude that the custom models were superior to conventional posts when composed by metal, but similar when composed of fiberglass.
206

Influência da contração de sinterização na adaptação de copings de Y-TZP: Efeito na distribuição de tensões / Influence of Sintering Shrinkage on the Fit of Y-TZP Copings: Effect on Stress Distribuition

Rezende, Carlos Eduardo Edwards 07 July 2015 (has links)
A longevidade das coroas cerâmicas depende, entre outros fatores, de sua adaptação ao pilar, bem como da distribuição das tensões nas mesmas. Não há um consenso sobre a melhor adaptação dos copings de zircônia feitos em CAD/CAM em relação aos métodos convencionais, podendo haver uma influência da contração de sinterização sobre esta. O presente estudo avaliou as alterações dimensionais decorrentes do processo de sinterização em três diferentes marcas comerciais de blocos de zircônia, relacionando-as com a adaptação de copings confeccionados por um sistema CAD/CAM, além de avaliar como a adaptação de tais copings poderia impactar na distribuição de tensões em coroas cerâmicas bi-camadas com estrutura de zircônia. A contração de sinterização das três marcas comerciais de zircônia foi obtida experimentalmente a partir da mensuração de espécimes geométricos. Trinta e seis copings de zircônia confeccionados por CAD/CAM foram divididos em três grupos (n=12): ZMAX a partir de blocos de IPS E.max ZirCad (Ivoclar Vivadent; Liechtenstein); ZYZ blocos de InCeram YZ (Vita Zahnfabrik; Alemanha) e; ZMC zircônia de manufatura controlada (Zirklein/Biodinâmica; Brasil). Os copings foram escaneados em micro-CT antes a após a sinterização para que as alterações dimensionais decorrentes do processo de sinterização fossem obtidas a partir da mensuração de cortes específicos. Os dados das alterações dimensionais obtidos para os espécimes geométricos e para os copings foram confrontados com as taxas de contração de sinterização informadas pelos fabricantes dos blocos de zircônia. Os copings sinterizados foram assentados sobre um pilar de zircônia e levados ao micro-CT para averiguação da adaptação interna e marginal dos mesmos. As mensurações foram realizadas pelo software ImageJ em 33 pontos diferentes. Os dados da adaptação possibilitaram a comparação estatística (p0,05) entre marcas comerciais e locais de mensuração, bem como a comparação entre a adaptação obtida experimentalmente e àquela determinada no software CAD/CAM para confecção dos copings. As imagens de micro-CT dos copings com menor e maior espaçamento foram utilizadas para a construção de modelos de elemento finito tridimensionais visando avaliar a distribuição de tensões em função do espaçamento coping/pilar na região oclusal. A contração de sinterização obtida para os espécimes geométricos foi 21,59±1,14%; 20,63±0,96% e 20,73±0,92% para os grupos ZMAX, ZYZ e ZMC, respectivamente. Todos os grupos apresentaram diferença estatística entre a taxa de contração do fabricante e a obtida experimentalmente. A análise das alterações dimensionais dos copings demonstrou incompatibilidade entre a taxa de contração ocorrida nos copings e àquela informada pelos fabricantes dos grupos ZMAX e ZMC. Também houve diferença entre a taxa de contração dos espécimes geométricos e a dos copings para todos os grupos estudados. Não houve uniformidade de contração de sinterização das paredes dos copings. Não houve diferença estatística entre os grupos para a adaptação marginal, havendo diferença apenas para a adaptação interna e entre as diferentes regiões mensuradas, havendo maior espaçamento na região oclusal. Considerando as diferentes faces axiais do copings, houve maior espaçamento na região vestibular. A comparação entre a adaptação obtida e àquela determinada pelo sistema CAD/CAM demonstrou diferença estatística em determinadas regiões mensuradas para todos os grupos. A avaliação da distribuição de tensões pelo método de elementos finitos demonstrou maior concentração de tensão no modelo com maior espaçamento entre copings e pilar na porção oclusal. Concluiu-se que não houve uniformidade na contração de sinterização, a marca comercial dos blocos de zircônia influenciou na adaptação, os parâmetros de espaçamento copings/pilar determinados no sistema CAD/CAM não foram obtidos na prática e, um maior espaçamento interno entre coping e pilar na região oclusal resultou em maior concentração de tensões na coroa cerâmica. / The longevity of ceramic crowns depends, among other factors, on its fit and the stress distribution. There is no consensus regarding the better fitting of zirconia CAD/CAM made crowns over conventional methods and may be an influence of zirconia sintering shrinkage on the abutment/coping spacing. This study aimed at evaluating the dimensional changes from sintering process of three zirconia blocks trademarks, relating them to the fit of CAD / CAM made zirconia copings, and to evaluate how the fit of such copings could impact on the stress distribution in bilayered Y-TZP based ceramic crowns. The sintering shrinkage of the three trademarks of zirconia was obtained experimentally from the measurement of geometric specimens. Thirty-six zirconia copings made by CAD / CAM were equally divided into three groups (n = 12): ZMAX - from blocks of IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ blocks (Vita Zahnfabrik, Germany) and; ZMC - controlled manufacturing zirconia (Zirklein/Biodinamica, Brazil). The copings were scanned in micro-CT before and after the sintering so that dimensional changes from the sintering process were obtained from measurements taken from specific slices. Data from dimensional changes obtained for the geometric specimens and for the copings were faced with the sintering shrinkage rates reported by the manufacturers of zirconia blanks. The sintered copings were settled on a zirconia abutment and taken to the micro-CT scanner to evaluate its marginal and internal fit. Thirty three different points were measured using the Image J software. The data enabled the statistical comparison (p 0,05) between trademarks and measurement sites, as well as the comparison between the fit obtained experimentally with that stipulated by the CAD / CAM software. The micro-CT images of copings with smaller and larger cement space were used to build finite element models to evaluate stress distribution as a function of the abutment/coping fit in the occlusal aspect. The sintering shrinkage obtained for the geometric specimens was 21.59 ± 1.14%, 20.63 ± 0.96% and 20.73 ± 0.92% for ZMAX, ZYZ and ZMC groups, respectively. All groups showed statistical difference between the sintering shrinkage rate reported by the manufacturer and those obtained experimentally. The copings dimensional changes analysis showed incompatibility between the rates of shrinkage occurred in copings and to that reported by the manufacturers of ZMAX and ZMC groups. There was also a difference between the sintering shrinkage rate of the geometric specimens and the copings for all groups. In general, the sintering shrinkage of the walls of the copings showed no uniformity. Considering the adaptation of copings, there was no statistical difference between the groups for marginal fit, with differences only for internal fit and between the different regions measured. The thicker gap was found in the occlusal aspect. Considering the different axial aspects of the coping, the thicker spacing was found in the buccal region. The comparison between the fit obtained experimentally with that determined by the CAD/CAM system showed statistically significant differences in certain measured regions for all groups. The evaluation of stress distribution by finite element method showed higher stress concentration in the model with thicker cement space on the occlusal aspect. It was concluded that the sintering shrinkage did not occur uniformly; the adaptation of copings differed from a trademark to another; the obtained fitting did not achieve parameters determined in the CAD / CAM system; and a higher internal spacing between coping and abutment in the occlusal aspect resulted in higher stress concentration in the ceramic bi-layered crowns.
207

Análise pelo método de elementos finitos, da distribuição de tensões em dentes com e sem remanescente coronário, utilizando diferentes pinos intra-radiculares

Ribeiro, João Paulo Filgueiras 28 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:27Z (GMT). No. of bitstreams: 1 Joao Paulo Filgueiras Ribeiro.pdf: 1425033 bytes, checksum: bf635e2252eb5599d0b6eabb6e2eb961 (MD5) Previous issue date: 2004-07-28 / RIBEIRO, J. P. F. Analysis, through the finite element techniques, the distribution of stress in tooth with or without remnant in the crown portion, using different post. 2004. 95p. Dissertação (Mestrado em Odontologia) – Universidade Estadual de Ponta Grossa, Ponta Grossa, 2004. Analyze, through the finite element techniques, the distribution of stress produce in models of an upper central incisor with or without dentin remnant in the crown portion, using five different systems of intraradicular post. The post used were: cast metal (Cu – AL alloy), carbon fiber, fiberglass, zirconium and titanium, having as a control group a healthy tooth. Two – dimensional models of a upper central incisor were building, with and without 2 mm of dentin remanesces on the crown portion. One load of 100 N was applying on the incisal portion of the palatine face with an inclination of 45 in relation of the axle along the tooth for all models. The stress results were obtain using the computational program ANSYS and express in the terms of the Von Mises stress. It can be concluded that significant differences stress distribution were found between the five post systems tested: the zirconium, cast metal alloy and titanium post produced high stress concentration in the radicular surface along the interface post/cement/dentin. The fiberglass and carbon fiber post presented a distribution of uniform stress along the radicular surface. The presence or absence of dentin remnant in the crown portion created differences in the stress distribution, the groups that had 2 mm of dentin remanesces distributed stress better than the groups without the 2mm of dentin remnant. / RIBEIRO, J. P. F. Análise pelo método de elementos finitos, da distribuição de tensões em dente com e sem remanescente coronário, utilizando diferentes pinos intra-radiculares. 2004. 95f. Dissertação (Mestrado em Odontologia) – Universidade Estadual de Ponta Grossa, Ponta Grossa, 2004. O objetivo do estudo foi analisar pelo Método de Elementos Finitos, a distribuição de tensões produzidas em modelos de um incisivo central superior com e sem remanescente de dentina na porção coronária, utilizando cinco diferentes sistemas de pinos intra-radiculares.Os pinos utilizados foram: núcleo metálico fundido, fibra de carbono, fibra de vidro, zircônio e titânio, tendo como grupo controle o dente hígido. Foram construídos modelos bi-dimensionais do incisivo central superior sem e com 2 mm de remanescente dentinário na porção coronária. Uma carga de 100 N foi aplicada no terço incisal da região palatina com uma inclinação de 45º em relação ao longo eixo do dente para todos os modelos criados. Com a análise dos dados no programa computacional “ANSYS” os resultados foram obtidos e expressos em função da Tensão de Von Mises. Concluiu-se que houve diferenças significativas na distribuição de tensão entre os cinco sistemas de pinos testados. Os pinos, zircônio, metálico fundido e titânio, promoveram maiores concentrações de tensões na região do conduto radicular ao longo da interface pino/cimento/dentina. Nos pinos de fibra de vidro e fibra de carbono houve uma distribuição de tensões mais uniforme ao longo da superfície radicular. Quando variou apenas a presença ou ausência do remanescente dentinário na porção coronária houve diferenças na distribuição de tensões, onde os grupos os quais tinham remanescente dentinário de 2 mm distribuíram melhor as forças.
208

Modelagem numérica de lajes mistas de aço e concreto em situação de incêndio / Numerical modelling of steel-concrete composite slabs in fire

Santos, Daniel Bomfim Rocha dos 12 May 2014 (has links)
As lajes mistas de aço e concreto consistem de um sistema estrutural formado por fôrmas de aço (chapas perfiladas) permanentes sobre a qual é lançado o concreto armado. Após a cura do concreto, esses elementos trabalham conjuntamente, garantindo o comportamento misto. Esse tipo de sistema é amplamente utilizado na construção civil brasileira, por propiciar diversas vantagens, como a não utilização de fôrmas de madeiras e escoras. Com a finalidade de avaliar o comportamento térmico, estrutural e termoestrutural acoplado desse tipo de sistema, foram desenvolvidos modelos numéricos em elementos finitos no pacote computacional TNO DIANA em duas etapas distintas. Na primeira etapa é feita uma análise térmica bidimensional, cujos campos térmicos na seção transversal da laje são calibrados por meio de resultados experimentais disponíveis na literatura, avaliando os principais parâmetros que influenciam na distribuição de temperatura na laje, como a emissividade resultante e a resistência térmica na interface aço/concreto. Nessa etapa também se desenvolve um pós-processador em Visual Basic 11.0 capaz de ler os campos térmicos gerados pelo DIANA e calcular o momento fletor plástico resistente em função do tempo de exposição ao fogo. Esses resultados são comparados com aqueles calculados de acordo o modelo de cálculo da ABNT NBR 14323:2013. A segunda etapa consiste no desenvolvimento de modelos numéricos tridimensionais para se avaliar o comportamento termoestrutural acoplado de lajes mistas simplesmente apoiadas. Nessa etapa, primeiramente se faz a validação e calibração dos modelos numéricos à temperatura ambiente, avaliando fatores como a simetria dos modelos e a resistência ao cisalhamento longitudinal na interface entre a fôrma de aço e o concreto. Posteriormente, se realiza a validação do modelo numérico em temperatura elevada por meio de resultados experimentais disponíveis na literatura, considerando os efeitos dos gradientes térmicos na degradação das propriedades mecânicas e na expansão térmica do aço e concreto. Após a calibração do modelo numérico tridimensional em temperatura ambiente e elevada, se realizam análises paramétricas considerando a influência da armadura positiva, da espessura fôrma de aço, da resistência à compressão do concreto, da altura da laje e do vão entre apoios, por meio da curva de incêndio padrão. Os resultados obtidos dos modelos numéricos tridimensionais são comparados com aqueles obtidos pelo método do momento fletor plástico, calculados por meio dos resultados dos modelos térmicos, e de acordo o modelo de cálculo da ABNT NBR 14323:2013. / Steel-concrete composite slabs consist on a structural system comprising of permanent steel sheeting on which reinforced concrete is cast. After the cure of concrete, these elements work in conjunction, ensuring the composite behavior. This structural system is widely used in Brazilian civil construction, especially for providing several advantages, such as no use of formwork and post shores. In order to assess thermal, structural and staggered flow-stress behavior of this structural system, finite elements numerical models were developed in software TNO DIANA in two distinct steps. In the first step a two-dimensional thermal analysis is carried out, whose thermal fields in the slab cross section are calibrated by experimental results available in the literature, evaluating the main parameters that affect the temperature distribution in the slab, as the resulting emissivity and thermal resistance in the steel/concrete interaction. In this stage is also developed a post-processor in Visual Basic 11.0, which is able to read the thermal fields generated by DIANA and calculate the plastic bending moment capacity versus fire exposure time. These results are compared with those calculated according to the ABNT NBR 14323:2013 calculation model. The second step consists in the development of three-dimensional numerical models to evaluate the staggered heat-flow behavior of simply supported composite slabs. In this step, first is done the calibration and validation of the numerical models at ambient temperature, assessing factors such as the symmetry of the models and the longitudinal shear resistance between steel sheeting and the concrete. Later, numerical models are validated in fire through experimental results available in the literature, considering the effects of thermal gradients in the degradation of the mechanical properties and thermal expansion of steel and concrete. After validation of the three-dimensional numerical models at ambient and elevated temperature, parametric analysis are performed considering the influence of sagging reinforcement, the thickness of steel sheeting, compressive strength of the concrete, the slab height and the span between supports, through standard fire curve. The bending resistance of tri-dimensional numerical models is compared with that obtained by the plastic theory, calculated through the results of two-dimensional thermal models, and according to ABNT NBR 14323:2013 calculation model.
209

"Influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos" / Thermal, mechanical load and pH cycling influence on adhesive systems bond strength to primary dentin.

Rocha, Rachel de Oliveira 16 December 2004 (has links)
Nesta pesquisa foi realizada a avaliação da influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos. Para tal, cavidades oclusais foram preparadas em 80 molares decíduos e restauradas com os sistemas adesivos Single Bond e Clearfil SE Bond e resina composta Z100. Os dentes restaurados com cada um dos sistemas adesivos foram divididos em oito grupos (n= 5), de acordo com as condições de tratamento: ciclagem térmica (2000 ciclos, 5°C e 55°C), ciclagem de pH (10 ciclos, 8 horas de imersão em solução desmineralizadora e 16 em solução remineralizadora), ciclagem mecânica (100.000 ciclos, 8 kg), térmica/pH, térmica/mecânica, pH/mecânica e térmica/pH/mecânica, além do grupo controle. Os dentes foram seccionados perpendicularmente à interface de união e foram obtidos espécimes com área de superfície aderida com cerca de 0,8 mm 2 . Os espécimes foram submetidos ao teste de microtração e à análise do padrão de fratura em microscopia eletrônica de varredura. Os valores obtidos, expressos em MPa, foram submetidos à Análise de Variância (p < 0,05). Não foram encontradas diferenças estatísticas significantes na comparação entre os sistemas adesivos avaliados nem para os grupos submetidos à aplicação dos estresses térmico, mecânico e térmico/pH. Os demais grupos apresentaram valores de resistência de união inferiores àqueles obtidos pelo grupo controle (p < 0,05) Fraturas do tipo adesiva/mista foram as mais prevalentes (95,9%). A resistência de união dos sistemas adesivos avaliados é negativamente influenciada pela aplicação combinada das tensões com naturezas distintas. / The influence of thermal, mechanical load and pH cycling on adhesive systems bond strength to primary dentin was evaluated. Occlusal cavities in 80 primary molars were prepared with diamond bur and restored with Single Bond and Clearfil SE Bond adhesive systems and Z100 composite. Teeth restored with each adhesive system were shared into eight groups according treatment condition: thermal cycling (2000 cycle, 5°C and 55°C), pH cycling (10 cycles, demineralization solution immersion to 8 hours and 16 hours in remineralization solution), mechanical load cycling (100.000 cycles, 8kg), thermal/pH, thermal/mechanical load, pH/mechanical load and thermal/pH/mechanical load, besides control groups. The teeth were transversally sectioned in two axis rendering 0,8mm 2 stick shaped specimen. Sticks were then submitted to microtensile bond testing with a crosshead speed of 1mm/min. Fracture analysis was performed by scanning electron microscopy. Bond strength means expressed in MPa were submitted to two-wav ANOVA (p<0.05). No statistically significant differences were found between the adhesive systems nor to thermal, mechanical load and thermal/pH stresses groups. Lower bond strength values were found to other groups compared to control (p<0.05). Adhesive/mixed failures were prevalent (95.9%). Bond strengths of evaluated adhesive systems were negatively influenced by distinct tension application.
210

Avaliação de próteses fixas sobre implantes com diferentes níveis de ajuste pilar/prótese: efeito da ciclagem termomecânica sobre diferentes parafusos protéticos e análise fotoelástica da transmissão de tensões / Evaluation of fixed implant-supported prostheses with different levels of abutment/prosthesis fit: the effect of thermomechanical cycling on different abutment screws and photoelastic analysis of stress transmission

Silva, Rafael Candido Pedroso e 05 June 2012 (has links)
O objetivo deste estudo foi verificar os efeitos da ciclagem termomecânica sobre parafusos protéticos, convencionais de titânio e com cobertura de carbono, usados para fixação de próteses parciais fixas com desajuste de 150µm entre pilar e prótese, utilizando próteses sem desajuste como controle. Após ciclagem termomecânica das próteses, foram verificadas a adaptação marginal, a perda de torque dos parafusos protéticos e análise fotoelástica da distribuição de tensões ao redor dos implantes. Foram confeccionadas 12 próteses fixas sobre implantes, as quais foram divididas inicialmente em dois grupos (n=6): grupo 1 - sem desajuste (controle); grupo 2 - com desajuste simulado de 150&mu;m. Todas as próteses foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios. Os conjuntos foram submetidos a um total de 2.000.000 de ciclos mastigatórios, sendo que estes ensaios foram feitos duas vezes e os grupos iniciais foram subdivididos, na primeira vez foram utilizados parafusos com cobertura de carbono: grupo 1A (adaptadas) e grupo 2A (desadaptadas) e na segunda vez parafusos de titânio convencionais: grupo 1B (adaptadas) e grupo 2B (desadaptadas). A perda de torque dos parafusos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). A adaptação marginal após o ensaio melhorou significativamente ao se utilizar parafusos convencionais nas próteses adaptadas: pré-molar (p=0,001) e molar (p=0,028); e desadaptadas: pré-molar (p=0,014) e molar (p=0,007); mas ao se utilizar parafusos cobertos com carbono, a adaptação melhorou somente no pré-molar (p=0,015) das próteses desadaptadas. Quanto à perda de torque dos parafusos protéticos houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre as próteses adaptadas e desadaptadas, no molar, em todos os tempos para ambos parafusos (p&le;0,05); No pré-molar houve diferença significante apenas para os parafusos cobertos com carbono em T0 (p=0,019) e T2 (p=0,044). Quando comparados os parafusos, nas próteses adaptadas houve diferenças significantes no pré-molar em T1 (p=0,026) e T2 (p=0,043); e no molar em T2 (p=0,032); nas próteses desadaptadas houve diferenças significantes apenas para o pré-molar em T1 (p=0,046). Em relação à análise fotoelástica qualitativa, observou-se que em geral a aplicação de carga (10Kgf) gerou maior concentração e intensidade de tensões nas próteses desadaptadas, quando comparadas às adaptadas. Pode-se concluir que a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das próteses; em relação a perda de torque houve diferenças estatisticamente significantes entre as próteses adaptadas e desadaptadas; o tratamento de superfície dos parafusos foi eficaz apenas para próteses adaptadas, a análise fotoelástica sugere que próteses com desadaptações marginais provocam maior tensão ao redor dos implantes. / The objective of this study was to investigate the effects of thermomechanical cycling on prosthetic screws, conventional titanium and carbon coated, used for fixation of fixed partial dentures (FDP) with 150&mu;m of misfit between abutment and prosthesis, using fitted prostheses as control. After thermomechanical cycling of prostheses were verified, the marginal fit, the torque loss of prosthetic screws and the photoelastic analysis of stress distribution around implants. Twelve implant-supported fixed partial dentures were prepared and initially divided into two groups (n=6): group 1 - fitted prostheses (control), group 2 - 150&mu;m of simulated misfit. All prostheses had their marginal fit evaluated before and after simulation of cycles. The sets were subjected to a total of 2 million of cycles. Each group was assayed twice: in the first time, carbon coated screws were used: group 1A (fitted) and group 2A (misfitted); and in a second time, conventional titanium screws were used: group 1B (fitted) and group 2B (misfitted). The torque loss of the screws was analyzed before (T0), after 1,000,000 (T1) and 2,000,000 cycles (T2). Marginal fit improved significantly when using conventional screws in fitted prostheses: premolar (p=0,001) and molar (p=0,028), and in misfitted prostheses: premolar (p=0,014) and molar (p=0,007), but when using carbon coated screws, fit improved only in the premolar (p=0,015) of the misfitted prostheses. Torque loss of prosthetic screws were significantly different before and after simulation of the cycles between the fitted and misfitted, in molar, at all times for both screws (p&le;0,05); and in the premolar, were significant differences were noted only for the carbon coated screws at T0 (p=0,019) and T2 (p=0,044).When comparing the screws in the fitted prostheses, significant differences were noted in pre-molar at T1 (p=0,026) and T2 (p=0,043), and in the molar at T2 (p=0,032); whereas in the misfitted prostheses, significant difference was noted only for premolar at T1 (p=0,046). It was observed in qualitative photoelastic analysis that the load application (10Kgf) generated higher concentration and intensity of stresses in the misfitted prostheses, when compared to fitted ones. It can be concluded that the simulation of thermomechanical cycles had an influence on marginal fit of the prostheses. In relation to torque loss, differences between fitted and misfitted prostheses were noted, but the surface treatment of screws was effective only for fitted prostheses, and the photoelastic analysis suggests that prostheses with marginal misfit causes more stress around the implants.

Page generated in 0.0373 seconds