• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 101
  • 24
  • 19
  • 19
  • 15
  • 5
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 242
  • 37
  • 33
  • 31
  • 26
  • 24
  • 23
  • 22
  • 21
  • 19
  • 19
  • 19
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Dual Frequency Reconfigurable Reflectarray Antenna Of Split Ring Elements With Rf Mems Switches

Guclu, Caner 01 September 2010 (has links) (PDF)
Dual band (K and Ka) electronically scanning reflectarray with RF MEMS switches is designed, implemented and measured. Unit cell of the reflect array is composed of conductor backed split-ring elements. In order to steer the beam, the phase of the incident circularly polarized wave is controlled by RF MEMS switches that modify the angular orientation of split-rings individually. Reflectarray is designed using unit cell approach with periodic boundary conditions. The antenna is fabricated by using surface micromachining process developed in METU MEMS Center. Radiation patterns of the antenna are measured and compared with the simulations. It has been shown that the reflectarray is capable of beam switching to 35&deg / in Ka band, 24&deg / in K band.
172

Optimal Allocation Of Sectionalizing Switches In Rural Distribution Systems

Daldal, Mustafa 01 February 2012 (has links) (PDF)
The distribution system which forms the final connection between customers and power source plays a vital role in an electrical network. Different studies show that substantial proportion of the customer interruptions occurs due to the failures on distribution network. The ongoing privatization process of the electrical distribution services in Turkey raises the importance of reliable and continuous electricity supply significantly. The new regulations come up with this privatization process and the electrical distribution companies are strictly required to comply with these regulations to ensure the reliability of the distribution network. The legal framework and severe punishments applied to the electrical distribution companies exceeding the continuity of supply indices force them to invest on their network in order to increase the reliability of their system. As the reliability of electricity supplied increases, investment cost also increases. However, low system reliability causes higher outage frequency and duration which will increase the damage of these outages to customers and also increases the cost of the distribution company as a result of the penalty payments. This tradeoff between Outage Cost and Utility Cost requires consideration of an optimization when determining the optimal reliability level. In rural areas where electrical distribution network consists of long radial overhead lines in arborescent structure, continuity of supply is a major problem due to the high failure rates. The implementation of protection devices having reclosing capability and automated sectionalizing switches enhances the continuity of supply on rural networks substantially. The balance between the cost associated with installation of switches and the reduction on Outage Cost is an important optimization issue for distribution network operators. In this thesis study an algorithm is developed in order to determine the optimum number and locations of the sectionalizing switches on a rural electrical distribution network in Turkey which gives an optimum investment level with an optimum Outage Cost.
173

Fluorescent and Photochromic Fluorescent Compounds for Applications in Optical Nanoscopy / Fluoreszierende und Photochrome Fluoreszierende Verbindungen zur Anwendung in der Optischen Nanoskopie

Polyakova, Svetlana 20 October 2009 (has links)
No description available.
174

Model predictive control of AC-to-AC converter voltage regulator

Chewele, Youngie Klyv 04 1900 (has links)
Thesis (MEng)--Stellenbosch University, 2014. / ENGLISH ABSTRACT: The development of fast and efficient processors, programmable devices and high power semiconductors has led to the increased use of semiconductors directly in the power supply path in order to achieve strict power quality standards. New and advanced algorithms are used in the process and calculated on-line to bring about the required fast response to voltage variations. Losses in high voltage semiconductors increase with increased operating frequencies. A balance between semiconductor power losses and power quality is achieved through control of power semiconductor switching frequencies. A predictive control algorithm to achieve high power quality and limit the power losses in the high power semiconductor switches through switching frequency control is discussed for a tap switched voltage regulator. The quality of power, voltage regulator topology and the control algorithm are discussed. Simulation results of output voltage and current are shown when the control algorithm is used to control the regulator. These results are verified by practical measurements on a synchronous buck converter. / AFRIKAANSE OPSOMMING: Die ontwikkeling van vinnige en doeltreffende verwerkers, programmeerbare toestelle en hoëdrywings halfgeleiers het gelei tot 'n groter gebruik van halfgeleiers direk in die kragtoevoer pad om streng elektriese toevoer kwaliteit standaarde te bereik. Nuwe en gevorderde algoritmes word gebruik in die proses en word aan-lyn bereken om die nodige vinnige reaksie tot spanningswisselinge te gee. Verliese in hoë-spannings halfgeleiers verhoog met hoër skakel frekwensies. 'n Balans tussen die halfgeleier drywingsverliese en spanningskwalteit is behaal deur die skakel frekwensie in ag te neem in die beheer. 'n Voorspellinde-beheer algoritme om ‘n hoë toevoerkwaliteit te bereik en die drywingsverliese in die hoëdrywingshalfgeleier te beperk, deur skakel frekwensie te beheer, is bespreek vir 'n tap-geskakelde spanning reguleerder. Die toevoerkwaliteit, spanningsreguleerder topologie en die beheer algoritme word bespreek. Simulasie resultate van die uittree-spanning en stroom word getoon wanneer die beheer algoritme gebruik word om die omsetter te beheer. Hierdie resultate is deur praktiese metings op 'n sinkrone afkapper.
175

Alocação de dispositivos de proteção e manobras para otimização da confiabilidade de sistemas elátricos de distribuição de energia com restrições de restabelecimento

Campo, Sergio Daniel Martinez January 2014 (has links)
Uma das principais metas das empresas concessionárias é fornecer energia a seus clientes de forma continua, confiável e com baixo custo. A qualidade do serviço de distribuição de energia é fiscalizada por órgãos reguladores do setor elétrico, sendo quantificada por métricas como o indicador de confiabilidade SAIDI (System Average Interruption Duration Index). A melhoria da confiabilidade dos sistemas de distribuição de energia elétrica é um assunto em destaque atualmente, tendo em vista a necessidade de um suprimento de energia cada vez mais confiável, para evitar as perdas econômicas que ocorrem com as interrupções. Neste contexto, este trabalho apresenta uma contribuição para a solução do problema de restabelecimento de sistemas de distribuição. A abordagem consiste no desenvolvimento de um modelo analítico de otimização, cujo objetivo principal é determinar a localização das chaves de manobras na rede que possibilite o restabelecimento efetivo da carga no período pós-falta. A viabilidade do restabelecimento é considerada através de restrições que garantem níveis adequados das tensões nas cargas, bem como a limitação da sobrecarga das linhas e as capacidades de reserva dos alimentadores adjacentes. A modelagem destas restrições é efetuada através de uma versão linear do fluxo de potência em termos das injeções nodais de correntes. As equações que descrevem o fluxo de potência são formuladas como funções das localizações das chaves de manobras no alimentador. A confiabilidade é caracterizada em termos da duração média das interrupções sustentadas, mensurada pelo indicador SAIDI. Visando à maior precisão na representação do efeito das faltas sobre a confiabilidade do alimentador, a metodologia agrega um modelo existente na literatura para alocação dos dispositivos de proteção de forma simultânea às chaves de manobras. A alocação dos dispositivos de proteção e manobras é sujeita a restrições técnicas e econômicas. Para resolver o modelo de otimização não-linear inteira mista, é usada uma técnica de otimização de uso geral, baseada no algoritmo Branch-and-Bound. Assim, metodologia permite a otimização determinística da confiabilidade do alimentador, garantindo o nível ótimo de confiabilidade e a racionalização dos investimentos por parte das concessionárias. Um estudo de caso é apresentado para avaliar a efetividade da metodologia na otimização da confiabilidade de um alimentador de distribuição real. / One of the main goals of utility companies is to provide energy to its customers continuously, reliably and cost effectively. The quality of power distribution service is supervised by regulators of the electricity sector, being quantified by metrics such as the reliability index SAIDI (System Average Interruption Duration Index). Improving the reliability of electricity distribution systems is a key issue nowadays, in view of the need for an increasingly reliable power supply in order to avoid the economic losses due to interruptions. In this context, this work presents a contribution to solve the distribution systems restoration problem. An analytical model is developed to determine locations of the sectionalizing switches in order to restore the system loads in the post-fault period. Restoration feasibility is considered by constraints that ensure adequate voltage levels on the system loads, emergency capacity of support feeders as well as line overloads. Constraints modeling is performed by a linear power flow based on current injection approach. Power flow equations are formulated as functions of switches locations. Reliability is considered in terms of average interruption durations measured by the SAIDI index. Aiming to a greater precision in representing the reliability impact of faults, the methodology aggregates a model from the literature for simultaneous allocation of protective devices and switches. Protective devices and switches allocation is subject to technical and economical constraints. The proposed model is solved by a general-use optimization technique, based on the branch-and-bound method. The proposed methodology makes possible the deterministic optimization of distribution reliability, as well as to rationalize investments of electric utilities. A case study is presented to evaluate the effectiveness of reliability optimization of a real distribution feeder.
176

Novel mechanical alignment and component fabrication for wavelength-selective optical switches

Wilkinson, Peter John January 2018 (has links)
No description available.
177

Micro-actionneurs piézoélectriques / Piezoelectric micro-actuators

Cueff, Matthieu 17 November 2011 (has links)
Le Titano-Zirconate de Plomb, ou PZT est un matériau piézoélectrique présentant de très bonnes performances pour l'actionnement des microsystèmes. Dans ce travail de thèse, nous nous proposons de répondre à la problématique de l'intégration du PZT par dépôt sol-gel. Dans une première partie, nous présenterons l'état de l'art des MEMS piézoélectriques et du PZT. Dans une seconde partie, nous montrerons comment obtenir des couches minces de PZT orientées (100) et (1111) de façon homogène, pour une des épaisseurs de 100 nm à 2µm. Dans une troisième partie, nous comparerons les propriétés ferroélectriques et piézoélectriques des films, en fonction de l'orientation. Pour l'orientation (100), nous avons pu mesurer un coefficient d31 supérieur à -150 pm/V et un coefficient e31,f de -16 C/m2. Pour l'orientation (111), nous avons mesuré un d31 de -100 pm/V et un e31,f de -14 C/m2. Pour expliquer les différences observées, nous avons également abordé le problème du blocage des parois de domaines. Dans une quatrième partie, nous présentons la fabrication et la caractérisation d'un interrupteur MEMS radiofréquences packagé et stabilisé en température fonctionnant à basse tension. A l'état bloqué, il présente une isolation de -44 dB à 2 GHz. A l'état passant, il présente des pertes d'insertion de -0.74 dB à 2 GHz. Dans cette partie, nous présentons également l'intégration d'une jauge de contraintes dans un actionneur piézoélectrique. Dans la dernière partie, nous présentons l'intégration de nos procédés dans des membranes sans dégradation des performances. Une étude préliminaire de fiabilité est également menée. Le mécanisme conduisant à la dégradation de nos composants est lié au vieillissement du matériau, ce qui montre que notre procédé de dépôt est maitrisé de façon homogène sur des substrats 200 mm. / PZT is a piezoelectric material which exhibits very good performances for microsystems actuation. In this work, the problem of sol-gel deposited PZT integration is discussed. First, state of the art of piezoelectric MEMS and PZT is presented. Then, the fabrication of homogeneous (100) and (111) oriented PZT thin films is presented. Layers thicknesses are comprised between 100 nm and 2 µm. Thirdly, ferroelectric and piezoelectric properties of the two oriented thin films are compared. For (100) oriented films, the d31 piezoelectric coefficient was greater than -150 pm/V and the e31,f reaches -16 C/m2. For (111) oriented films, the d31 and e31,f reach -100 pm/V and -14 C/m2 respectively. To explain observed differences, domain walls pinning was studied. Next, fabrication and characterization of a low voltage, fully packaged and thermally stabilized RF MEMS piezoelectric switch is presented. At the off-state, the switch isolation is -44 dB at 2 GHz. At the on-state, insertion losses are -0.74 dB at 2 GHz. The integration of a metallic gauge in a piezoelectric cantilever is also presented. Finally, developed processes are integrated in membranes fabrication without any degradation. A preliminary reliability study is presented. The fail mechanism of our components is an aging mechanism. This shows that our sol-gel deposition process is well-controlled on 8 inches wafers.
178

Implementação de protótipo de resfriador termoelétrico por efeito Peltier aplicado a dispositivos semicondutores de potência

Moraes, Thiago Finotti de 27 November 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In any electrical or electronic circuit, thermal energy is a quantity that is always present and generally must be considered in the specifications of any application. In many cases, the heat from the Joule effect, as well as from other internal and irreversible losses, represent the biggest share of maximum heat that a system can dissipate under normal operation. In Power Electronics, the study and application of semiconductor power switches are particularly important. Many solutions have been developed over the years aiming to mitigate electrical losses and heat built-up in semiconductor power switches. It is important to state that the current amount of research available to academics and the general public into thermal effects on semiconductor power switches is not as wide as that concerning the applications of those switches. It is remarkably reduced the amount of work concerning active cooling of semiconductor power switches and components, as well as concerning the behavior of semiconductor power switches and components under active cooling. Thus, there is a lack of studies aiming the investigation of the behavior of electric switches under different thermal loads. Because of this lack, this work is focused on a proposal of an equipment actively cools semiconductor power switches used in Power Electronics, particularly those usually found in switched mode power supplies. The main purpose of this work is to develop an equipment for being used on a lab bench based on Peltier technology that sets thermal action on semiconductor power switches, making possible the evaluation of the behavior of these switches under different thermal exposures and temperatures. Fist, the Peltier technology was investigated and, later on, a solution was developed allowing the usage of this technology on semiconductor power switches. A detailed description and the calculations of the developed thermoelectric system are presented. The results of this work are presented as a comparative study of the behavior and limits of performance of MOSFETs in DC-DC Boost converters under active cooling compared to traditional passive heat sinks. During active cooling the MOSFET was cooled below ambient temperature, assuring its external thermal safety. The experimental results confirm the operation as intended. The main confirmed advantages were greater dissipated power, increase of thermal margin and capacity of actively transferring heat to an overloaded area to another place. / Em qualquer circuito elétrico ou eletrônico, a energia térmica é uma grandeza que está sempre presente e em geral deve ser levada em conta nas especificações de qualquer aplicação. Em vários casos, o calor decorrente do efeito joule, bem como de outras perdas internas e irreversíveis, representam a parcela mais impactante da quantidade de calor limítrofe que um sistema consegue dissipar em operação normal. São de particular importância em Eletrônica de Potência o estudo e a aplicação de chaves semicondutoras. Várias soluções têm sido desenvolvidas ao longo dos anos no sentido de mitigar as perdas elétricas em chaves semicondutoras, bem como o aumento de temperatura nas mesmas durante operação. É importante frisar que atualmente a quantidade de pesquisas disponíveis ao público acadêmico e geral sobre os efeitos térmicos em chaves semicondutoras não é tão ampla quanto sobre as aplicações dessas chaves. É particularmente reduzida a quantidade de trabalhos ligados ao resfriamento ativo de chaves e componentes elétricos, assim como de trabalhos voltados ao comportamento de chaves e componentes mediante resfriamento ativo. Sendo assim, existe uma carência de estudos que objetivem a investigação do comportamento de chaves semicondutoras mediante distintas cargas térmicas. Diante desta carência, o foco deste trabalho é apresentar uma proposta de equipamento que atue termicamente, seja aquecendo ou resfriando, sobre chaves semicondutoras utilizadas em eletrônica de potência, particularmente aquelas comumente usadas em fontes elétricas chaveadas. O objetivo principal deste trabalho é desenvolver um equipamento para uso em bancada baseado na tecnologia Peltier que resfrie ativamente chaves semicondutoras, possibilitando a avaliação de comportamento das mesmas mediante diferente exposições térmicas e temperaturas. Primeiramente a tecnologia Peltier foi investigada e, posteriormente, foi desenvolvida uma solução que permite a utilização desta tecnologia em dispositivos semicondutores de distintos encapsulamentos. Uma descrição detalhada e os cálculos de dimensionamento do sistema termoelétrico desenvolvido são apresentados. Os resultados deste trabalho são apresentados em forma de estudo comparativo sobre o comportamento e limites de desempenho de MOSFETs em conversores CC-CC Boost mediante resfriamento ativo frente aos tradicionais dissipadores passivos. Durante resfriamento ativo o MOSFET foi resfriado à temperatura subambiente e constante, garantindo sua a segurança térmica relacionada à temperatura do encapsulamento. Os resultados experimentais confirmam a operação do protótipo conforme a proposta deste trabalho. As principais vantagens confirmadas foram maior potência dissipada, aumento da margem térmica e capacidade de transferir ativamente calor de uma área sobrecarregada para outro local. / Mestre em Ciências
179

Alocação de dispositivos de proteção e manobras para otimização da confiabilidade de sistemas elátricos de distribuição de energia com restrições de restabelecimento

Campo, Sergio Daniel Martinez January 2014 (has links)
Uma das principais metas das empresas concessionárias é fornecer energia a seus clientes de forma continua, confiável e com baixo custo. A qualidade do serviço de distribuição de energia é fiscalizada por órgãos reguladores do setor elétrico, sendo quantificada por métricas como o indicador de confiabilidade SAIDI (System Average Interruption Duration Index). A melhoria da confiabilidade dos sistemas de distribuição de energia elétrica é um assunto em destaque atualmente, tendo em vista a necessidade de um suprimento de energia cada vez mais confiável, para evitar as perdas econômicas que ocorrem com as interrupções. Neste contexto, este trabalho apresenta uma contribuição para a solução do problema de restabelecimento de sistemas de distribuição. A abordagem consiste no desenvolvimento de um modelo analítico de otimização, cujo objetivo principal é determinar a localização das chaves de manobras na rede que possibilite o restabelecimento efetivo da carga no período pós-falta. A viabilidade do restabelecimento é considerada através de restrições que garantem níveis adequados das tensões nas cargas, bem como a limitação da sobrecarga das linhas e as capacidades de reserva dos alimentadores adjacentes. A modelagem destas restrições é efetuada através de uma versão linear do fluxo de potência em termos das injeções nodais de correntes. As equações que descrevem o fluxo de potência são formuladas como funções das localizações das chaves de manobras no alimentador. A confiabilidade é caracterizada em termos da duração média das interrupções sustentadas, mensurada pelo indicador SAIDI. Visando à maior precisão na representação do efeito das faltas sobre a confiabilidade do alimentador, a metodologia agrega um modelo existente na literatura para alocação dos dispositivos de proteção de forma simultânea às chaves de manobras. A alocação dos dispositivos de proteção e manobras é sujeita a restrições técnicas e econômicas. Para resolver o modelo de otimização não-linear inteira mista, é usada uma técnica de otimização de uso geral, baseada no algoritmo Branch-and-Bound. Assim, metodologia permite a otimização determinística da confiabilidade do alimentador, garantindo o nível ótimo de confiabilidade e a racionalização dos investimentos por parte das concessionárias. Um estudo de caso é apresentado para avaliar a efetividade da metodologia na otimização da confiabilidade de um alimentador de distribuição real. / One of the main goals of utility companies is to provide energy to its customers continuously, reliably and cost effectively. The quality of power distribution service is supervised by regulators of the electricity sector, being quantified by metrics such as the reliability index SAIDI (System Average Interruption Duration Index). Improving the reliability of electricity distribution systems is a key issue nowadays, in view of the need for an increasingly reliable power supply in order to avoid the economic losses due to interruptions. In this context, this work presents a contribution to solve the distribution systems restoration problem. An analytical model is developed to determine locations of the sectionalizing switches in order to restore the system loads in the post-fault period. Restoration feasibility is considered by constraints that ensure adequate voltage levels on the system loads, emergency capacity of support feeders as well as line overloads. Constraints modeling is performed by a linear power flow based on current injection approach. Power flow equations are formulated as functions of switches locations. Reliability is considered in terms of average interruption durations measured by the SAIDI index. Aiming to a greater precision in representing the reliability impact of faults, the methodology aggregates a model from the literature for simultaneous allocation of protective devices and switches. Protective devices and switches allocation is subject to technical and economical constraints. The proposed model is solved by a general-use optimization technique, based on the branch-and-bound method. The proposed methodology makes possible the deterministic optimization of distribution reliability, as well as to rationalize investments of electric utilities. A case study is presented to evaluate the effectiveness of reliability optimization of a real distribution feeder.
180

Alocação de dispositivos de proteção e manobras para otimização da confiabilidade de sistemas elátricos de distribuição de energia com restrições de restabelecimento

Campo, Sergio Daniel Martinez January 2014 (has links)
Uma das principais metas das empresas concessionárias é fornecer energia a seus clientes de forma continua, confiável e com baixo custo. A qualidade do serviço de distribuição de energia é fiscalizada por órgãos reguladores do setor elétrico, sendo quantificada por métricas como o indicador de confiabilidade SAIDI (System Average Interruption Duration Index). A melhoria da confiabilidade dos sistemas de distribuição de energia elétrica é um assunto em destaque atualmente, tendo em vista a necessidade de um suprimento de energia cada vez mais confiável, para evitar as perdas econômicas que ocorrem com as interrupções. Neste contexto, este trabalho apresenta uma contribuição para a solução do problema de restabelecimento de sistemas de distribuição. A abordagem consiste no desenvolvimento de um modelo analítico de otimização, cujo objetivo principal é determinar a localização das chaves de manobras na rede que possibilite o restabelecimento efetivo da carga no período pós-falta. A viabilidade do restabelecimento é considerada através de restrições que garantem níveis adequados das tensões nas cargas, bem como a limitação da sobrecarga das linhas e as capacidades de reserva dos alimentadores adjacentes. A modelagem destas restrições é efetuada através de uma versão linear do fluxo de potência em termos das injeções nodais de correntes. As equações que descrevem o fluxo de potência são formuladas como funções das localizações das chaves de manobras no alimentador. A confiabilidade é caracterizada em termos da duração média das interrupções sustentadas, mensurada pelo indicador SAIDI. Visando à maior precisão na representação do efeito das faltas sobre a confiabilidade do alimentador, a metodologia agrega um modelo existente na literatura para alocação dos dispositivos de proteção de forma simultânea às chaves de manobras. A alocação dos dispositivos de proteção e manobras é sujeita a restrições técnicas e econômicas. Para resolver o modelo de otimização não-linear inteira mista, é usada uma técnica de otimização de uso geral, baseada no algoritmo Branch-and-Bound. Assim, metodologia permite a otimização determinística da confiabilidade do alimentador, garantindo o nível ótimo de confiabilidade e a racionalização dos investimentos por parte das concessionárias. Um estudo de caso é apresentado para avaliar a efetividade da metodologia na otimização da confiabilidade de um alimentador de distribuição real. / One of the main goals of utility companies is to provide energy to its customers continuously, reliably and cost effectively. The quality of power distribution service is supervised by regulators of the electricity sector, being quantified by metrics such as the reliability index SAIDI (System Average Interruption Duration Index). Improving the reliability of electricity distribution systems is a key issue nowadays, in view of the need for an increasingly reliable power supply in order to avoid the economic losses due to interruptions. In this context, this work presents a contribution to solve the distribution systems restoration problem. An analytical model is developed to determine locations of the sectionalizing switches in order to restore the system loads in the post-fault period. Restoration feasibility is considered by constraints that ensure adequate voltage levels on the system loads, emergency capacity of support feeders as well as line overloads. Constraints modeling is performed by a linear power flow based on current injection approach. Power flow equations are formulated as functions of switches locations. Reliability is considered in terms of average interruption durations measured by the SAIDI index. Aiming to a greater precision in representing the reliability impact of faults, the methodology aggregates a model from the literature for simultaneous allocation of protective devices and switches. Protective devices and switches allocation is subject to technical and economical constraints. The proposed model is solved by a general-use optimization technique, based on the branch-and-bound method. The proposed methodology makes possible the deterministic optimization of distribution reliability, as well as to rationalize investments of electric utilities. A case study is presented to evaluate the effectiveness of reliability optimization of a real distribution feeder.

Page generated in 0.0168 seconds