• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 7
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização de sistemas de semiclimatização de ambiente, em galpões para frangos de corte, no sudoeste de Goiás / Characterization of environment semi-acclimatization systems in broiler shed, in the southeastern Goiás

Moraes, Sandra Regina Pires de 30 August 2002 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-08T17:18:43Z No. of bitstreams: 1 texto completo.pdf: 2991785 bytes, checksum: 69d9d4e7c970b9b3df118646381946eb (MD5) / Made available in DSpace on 2017-02-08T17:18:43Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2991785 bytes, checksum: 69d9d4e7c970b9b3df118646381946eb (MD5) Previous issue date: 2002-08-30 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / No desenvolvimento da produção avícola, as pesquisas na área de ambiência têm assumido papel primordial, introduzindo novos conceitos, como alta densidade de alojamento, sistemas de ventilação, sistemas de resfriamento evaporativo, controle automático de variáveis ambientais e equipamentos, bem como semiclimatização de galpões. No sudoeste de Goiás, com os resultados negativos de desempenho zootécnico e sanitário das aves nos galpões semiclimatizados, surgiram sérios problemas para o setor, como redução na remuneração dos integrados, aumento no tempo de retorno do investimento, inadimplência no pagamento das prestações do financiamento dos galpões, aumento no custo de produção do frango e insatisfação generalizada nos diversos segmentos da avicultura industrial da região. As pesquisas para determinação da eficiência dos sistemas de semiclimatização no Brasil ainda são incipientes em se tratando de galpões avícolas, pois a maioria das pesquisas sobre o assunto tem sido desenvolvida em regiões de clima temperado. As instalações onde a pesquisa foi desenvolvida foram escolhidas com base nas diferenças dos projetos de semiclimatização implantados, visando a caracterização dos mais díspares sistemas. Os dados foram obtidos em sete galpões para frangos de corte, criados em sistema de alta densidade de alojamento, no sudoeste de Goiás. Considerando a importância do conforto térmico ambiental na criação de aves, este estudo teve por objetivo geral a caracterização dos diversos sistemas de semiclimatização de ambiente, em galpões para frangos de corte, no sudoeste de Goiás. O trabalho foi realizado no município de Jataí, Goiás, em sete galpões para frangos de corte, de propriedade de três integrados da Frango Gale S/A, em escala comercial, com largura de 12,0 m, comprimento de 120,0 m, pé-direito de 3,0 m, cobertura em duas águas, beiral de 0,5 m, inclinação de 30o para coberturas com telhas de barro e 15o para coberturas com telhas de cimento-amianto e alumínio. Para caracterizar o ambiente térmico, foram registrados, durante o período experimental, valores de temperatura de globo negro, bulbo seco, bulbo úmido e velocidade do ar, a cada duas horas, durante o período das 0 às 24 horas, na altura das aves, em diversos pontos no interior dos galpões. Com base nesses resultados, foram obtidos os valores de umidade relativa (UR) e o índice de temperatura de globo negro e umidade (ITGU) de cada tratamento. Nas condições de realização deste trabalho, e pelos resultados obtidos, concluiu-se que: os frangos de corte, a partir de 21 dias de vida, e nos horários mais quentes do dia (12 às 16 horas), estiveram em condições de estresse por calor, determinado por valores de ITGU acima de 76, ao longo de todo o galpão; a UR, nos tratamentos testados, foram estatisticamente iguais entre 12 e 16 horas, apesar de apresentarem valores em torno de 50%, muito abaixo dos 80% esperados para galpões semiclimatizados com resfriamento evaporativo; e, de forma geral, os sistemas estudados foram ineficientes em promover melhorias térmicas ambientais, havendo ainda a possibilidade de redução da temperatura do ar em cerca de 7 oC, com o aumento da sua eficiência. / For poultry production improvement, the research in the field of environment is assuming an important role, by introducing new concepts like high lodging density, ventilation systems, evaporative cooling systems, automatic control equipments for atmospheric variables and also semi-acclimatization of sheds. In the southeastern Goiás, having poor husbandry and sanitary results of bird performance in the semi-acclimatized sheds, has given rise to serious problems in the sector, that include reduced income of the integrated farmers, increased time period for investment returns, default on installment payments of loans acquired for shed construction, increased cost of broiler production and a generalized dissatisfaction of various segments involved in poultry industry of the region. The research to determine efficiency of semi-acclimatization systems in Brazil is yet incipient for poultry sheds, and most research has been done in temperate climate regions. Considering characterization of diverse systems, selection was based on the differences of installed semi-acclimatization systems. The data were obtained from seven broiler sheds of high lodging density, situated in south-eastern Goiás, Considering the importance of atmospheric thermal comfort for broiler raising, the general objective of this study was to characterize different atmosphere semi- acclimatization systems used in the broiler sheds in the south-eastern of Goiás. The study was done in the municipality of Jataí, in seven commercial broiler sheds, belonging to three integrators Frango Gale S/A, which were 12.0 m, 120,0 m long and 3.0 m high, with the tile roofing of two waters, and eaves of 0.5m, inclination of 30 o for the roof of earthen tiles, and 15 o for cement-asbestos- aluminum tiles. The black globe, dry and wet bulb temperatures and wind velocity, at the bird height were measured every two hours, from 00 to 24 h, at different points of the shed during the entire experimental period to characterize the thermal atmosphere. On the basis of these results relative humidity (rh) and the black globe temperature index and moisture (BGTIM) of each treatment were calculated. Under conditions of this work, and by the results obtained, it was concluded that: A) the 21-day old broilers, during the warmest hours of the day (12 to 16 h.) were under heat stress, as determined from the BGTIM value above 76 throughout the shed, 2) The rh of the treatments was statistically similar between 12 to 16 hours, despite showing values of about 50%, which is much below the expected 80% for semi-acclimatized sheds fitted with evaporative cooling; C) in general, the system studied were inefficient in improving atmospheric thermal comfort, because there was still the possibility of reducing air temperature by 7 o C by the existing system, if the efficiency was improved. / Tese importada do Alexandria
2

Variáveis ambientais e ergonômicas na operação com microtrator / Environmental and ergonomic variables in operation microtractor

Estevam, Francisca Nivanda de Lima January 2015 (has links)
ESTEVAM, Francisca Nivanda de Lima. Variáveis ambientais e ergonômicas na operação com microtrator. 2015. Dissertação (Mestrado em Engenharia Agrícola)-Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Vitor Campos (vitband@gmail.com) on 2016-10-13T23:32:18Z No. of bitstreams: 1 2015_dis_fnlestevam.pdf: 2828151 bytes, checksum: e2c08ba228f96c48e73c399d6e655f80 (MD5) / Approved for entry into archive by Jairo Viana (jairo@ufc.br) on 2016-10-18T18:45:04Z (GMT) No. of bitstreams: 1 2015_dis_fnlestevam.pdf: 2828151 bytes, checksum: e2c08ba228f96c48e73c399d6e655f80 (MD5) / Made available in DSpace on 2016-10-18T18:45:04Z (GMT). No. of bitstreams: 1 2015_dis_fnlestevam.pdf: 2828151 bytes, checksum: e2c08ba228f96c48e73c399d6e655f80 (MD5) Previous issue date: 2015 / The use of microtratores in family farming optimized the work, but still, did not exclude the operator of the activity of risk, because it gets the job done in fully exposed open field the variation in climatic conditions, especially solar radiation, temperature and humidity relative, apart from the loud noise and vibration produced by microtractor. The characterization of environmental and occupational hazards produced by the machine are needed for the development of strategies that can minimize risk and provide conditions for the operator to perform their activities without compromising their condition. The study was conducted at the Experimental Farm Crop Drought (FELS) of the Federal University of Ceará (UFC) in the municipality of Quixadá, central backwoods of Ceará. We used a microtractor model TC14 Super (motor cultivator) brand Yanmar Agritech, coupled to a rotary tiller. For measurements of climate variables, operator and microtractor were used sensors and devices installed in them. The experiment was done factorial 3x5, which were used three speeds to five times throughout the day. The data were submitted to variance analysis and the averages were compared by Tukey test at 5% probability. It was concluded that the activity carried out by microtractor operator in the city of Quixadá-Ceará is considered stressful, due to the high thermal load and municipal climate feature. All methods used were of value to characterize the activity that proved unhealthy for noise and vibration for wholesome. The OWAS (Ovako Working Posture Analysing System) method was effective to identify ergonomic risk of the activity, and operator's back part of the most affected body, the operator's tendency to tilt during activity, it is recommended to implement fitness labor, stretches before and after activity to reduce the risk of muscle injury and back pain. / A utilização de microtratores na agricultura familiar otimizou o trabalho, mas ainda assim, não excluiu totalmente o operador dos riscos da atividade, pois o mesmo realiza o trabalho em campo aberto totalmente exposto a variação das condições climáticas, principalmente a radiação solar, temperatura e umidade relativa, além do ruído intenso e da vibração produzida pelo microtrator. A caracterização deste ambiente e dos riscos laborais produzidos pela máquina são necessários para o desenvolvimento de estratégias que possam minimizar os riscos e dar condições ao operador de desempenhar sua atividade sem comprometimento da sua condição física. O trabalho foi realizado na Fazenda Experimental Lavoura Seca (FELS) da Universidade Federal do Ceará (UFC) localizada no município de Quixadá, sertão central do Ceará. Utilizou-se um microtrator modelo TC14 Super (cultivador motorizado), marca Yanmar Agritech, acoplado a uma enxada rotativa. Para as medições das variáveis climáticas, do operador e do microtrator foram utilizados sensores e aparelhos instalados nos mesmos. O delineamento experimental foi feito esquema fatorial 3x5, onde foram utilizadas três velocidades para cinco horários ao longo do dia. Os dados obtidos foram submetidos à análise de variância, sendo as médias comparadas pelo teste de Tukey a 5% de probabilidade. Concluiu-se que a atividade realizada pelo operador de microtrator no município de Quixadá-Ceará é considerada estressante, devido à alta carga térmica e característica do clima do município. Todos os métodos utilizados foram de valia para caracterização da atividade que se mostrou insalubre para o ruído e salubre para vibração. O método OWAS (Ovako Working Posture Analysing System) foi eficaz para identificar o risco ergonômico da atividade, sendo as costas do operador a parte do corpo mais afetada, pela tendência do operador de se inclinar durante a atividade, recomenda-se a implementação de ginástica laboral, alongamentos antes e depois da atividade, para diminuir o risco de lesões musculares e lombalgias.
3

Dimensionamento e avaliação do ciclo de refrigeração de sistema de climatização automotivo. / Sizing and evaluation of an automotive climate system refrigeration cycle.

Santos, Eduardo Oliveira dos 02 September 2005 (has links)
O ser humano consome grandes quantidades de energia para satisfazer as suas necessidades de conforto. Dentro do setor automotivo, depois da energia consumida com a mobilidade em si, o ar condicionado é o maior consumidor. O sistema de climatização para aplicações automotivas tem características particulares, diferentes de sistemas de climatização para outros ambientes. Em uma aplicação automotiva a variação de condições é bastante significativa, como por exemplo, a carga solar que é imposta, a velocidade do veículo, umidade do ar, as temperaturas interna e externa, variação do número e da posição dos ocupantes no interior do veículo, diferentes regimes de rotação e carga do motor, etc. O sistema deve, portanto, ser projetado para funcionar sob todas estas condições e propiciar condições de conforto térmico com o menor consumo de energia. No presente trabalho o objetivo é o projeto e a simulação de um ciclo de refrigeração que atenda aos requerimentos de carga térmica para um automóvel compacto em um ensaio específico realizado em túnel de vento. A partir da carga térmica, o ciclo de refrigeração é dimensionado seguindo-se o procedimento de projeto, que engloba o dimensionamento dos componentes principais como compressor, condensador, evaporador e o dispositivo de expansão. Os resultados dos cálculos teóricos são comparados com o dimensionamento do veículo real, permitindo se chegar a conclusões sobre o projeto. A avaliação do desempenho do sistema projetado é realizada por meio de um procedimento de simulação proposto, e os resultados comparados com os do veículo testado. O objeto de estudo é o sistema de refrigeração de um veículo compacto de quatro portas de fabricação nacional, submetido a um teste de desempenho do ciclo em um túnel de vento. O procedimento de dimensionamento pode ser usado para o projeto básico do sistema de refrigeração. Os resultados obtidos com o modelo de simulação proposto são bastante razoáveis. O modelo pode ser utilizado para prever o resultado de modificações no ciclo de refrigeração, como a troca de componentes, ou mesmo para prever o funcionamento do sistema sob outras condições de operação. A utilização do modelo fica restrita aos limites da validade dos modelos semi-empíricos dos componentes, não sendo recomendada a utilização fora desses limites. Ainda assim, a faixa de aplicação é grande o suficiente para simular a maioria das condições de trabalho encontradas na climatização veicular. / Human being spends a large amount of energy to satisfy its comfort needs. In the automotive applications, air conditioning is the second larger energy consumption system, after the mobility system itself. The refrigeration system for automotive application has peculiar characteristics, which are different from other refrigeration systems (e.g. buildings, food refrigeration, etc). In an automotive application, variation of several conditions are highly significant, such as the sun load, ambient temperature and humidity, the number and position of the occupants inside the vehicle, different engine loads and speeds and so on. The system must, therefore, be designed to operate satisfactorily under all these conditions and to provide thermal comfort with smallest possible energy consumption. The objective of this work is to present the project and simulation of a refrigeration cycle for a compact size vehicle in order to meet thermal load requirements of a specific wind tunnel test. From the thermal load, the refrigeration cycle is designed according to a design procedure, which includes the sizing of main components such as compressor, condenser, evaporator and expansion device. The results of the calculations are compared with the actual vehicle design. The performance evaluation is achieved by using a proposed simulation procedure, and the simulation results are compared with the actual vehicle test results. The study is conducted on the refrigerating system of a 4-door compact size vehicle locally manufactured, which was submitted to a refrigeration cycle performance test in a wind tunnel. The design procedure can be used for sizing a baseline refrigeration cycle. The results achieved with the proposed simulation model are acceptable. The model can be used to predict the impact of a modification in refrigeration cycle such as a component change, or even to predict the system balance point under different operating conditions. The application of the model is restricted to the range of validation of the component semiempirical models, so that the use beyond these limits is not recommended. The range of application, however, is wide enough to accommodate most of the operating conditions found in the vehicular refrigeration applications.
4

Dimensionamento e avaliação do ciclo de refrigeração de sistema de climatização automotivo. / Sizing and evaluation of an automotive climate system refrigeration cycle.

Eduardo Oliveira dos Santos 02 September 2005 (has links)
O ser humano consome grandes quantidades de energia para satisfazer as suas necessidades de conforto. Dentro do setor automotivo, depois da energia consumida com a mobilidade em si, o ar condicionado é o maior consumidor. O sistema de climatização para aplicações automotivas tem características particulares, diferentes de sistemas de climatização para outros ambientes. Em uma aplicação automotiva a variação de condições é bastante significativa, como por exemplo, a carga solar que é imposta, a velocidade do veículo, umidade do ar, as temperaturas interna e externa, variação do número e da posição dos ocupantes no interior do veículo, diferentes regimes de rotação e carga do motor, etc. O sistema deve, portanto, ser projetado para funcionar sob todas estas condições e propiciar condições de conforto térmico com o menor consumo de energia. No presente trabalho o objetivo é o projeto e a simulação de um ciclo de refrigeração que atenda aos requerimentos de carga térmica para um automóvel compacto em um ensaio específico realizado em túnel de vento. A partir da carga térmica, o ciclo de refrigeração é dimensionado seguindo-se o procedimento de projeto, que engloba o dimensionamento dos componentes principais como compressor, condensador, evaporador e o dispositivo de expansão. Os resultados dos cálculos teóricos são comparados com o dimensionamento do veículo real, permitindo se chegar a conclusões sobre o projeto. A avaliação do desempenho do sistema projetado é realizada por meio de um procedimento de simulação proposto, e os resultados comparados com os do veículo testado. O objeto de estudo é o sistema de refrigeração de um veículo compacto de quatro portas de fabricação nacional, submetido a um teste de desempenho do ciclo em um túnel de vento. O procedimento de dimensionamento pode ser usado para o projeto básico do sistema de refrigeração. Os resultados obtidos com o modelo de simulação proposto são bastante razoáveis. O modelo pode ser utilizado para prever o resultado de modificações no ciclo de refrigeração, como a troca de componentes, ou mesmo para prever o funcionamento do sistema sob outras condições de operação. A utilização do modelo fica restrita aos limites da validade dos modelos semi-empíricos dos componentes, não sendo recomendada a utilização fora desses limites. Ainda assim, a faixa de aplicação é grande o suficiente para simular a maioria das condições de trabalho encontradas na climatização veicular. / Human being spends a large amount of energy to satisfy its comfort needs. In the automotive applications, air conditioning is the second larger energy consumption system, after the mobility system itself. The refrigeration system for automotive application has peculiar characteristics, which are different from other refrigeration systems (e.g. buildings, food refrigeration, etc). In an automotive application, variation of several conditions are highly significant, such as the sun load, ambient temperature and humidity, the number and position of the occupants inside the vehicle, different engine loads and speeds and so on. The system must, therefore, be designed to operate satisfactorily under all these conditions and to provide thermal comfort with smallest possible energy consumption. The objective of this work is to present the project and simulation of a refrigeration cycle for a compact size vehicle in order to meet thermal load requirements of a specific wind tunnel test. From the thermal load, the refrigeration cycle is designed according to a design procedure, which includes the sizing of main components such as compressor, condenser, evaporator and expansion device. The results of the calculations are compared with the actual vehicle design. The performance evaluation is achieved by using a proposed simulation procedure, and the simulation results are compared with the actual vehicle test results. The study is conducted on the refrigerating system of a 4-door compact size vehicle locally manufactured, which was submitted to a refrigeration cycle performance test in a wind tunnel. The design procedure can be used for sizing a baseline refrigeration cycle. The results achieved with the proposed simulation model are acceptable. The model can be used to predict the impact of a modification in refrigeration cycle such as a component change, or even to predict the system balance point under different operating conditions. The application of the model is restricted to the range of validation of the component semiempirical models, so that the use beyond these limits is not recommended. The range of application, however, is wide enough to accommodate most of the operating conditions found in the vehicular refrigeration applications.
5

Influência do clima no desempenho energético de condicionador de ar com tecnologia VRF em condição de carga parcial para hotéis

Xavier, Ademilson dos Santos 13 October 2016 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2017-02-08T12:58:24Z No. of bitstreams: 1 Ademilson dos Santos Xavier_.pdf: 9916385 bytes, checksum: 8bcbfe8f2b36b5a58781ce2518c1bb83 (MD5) / Made available in DSpace on 2017-02-08T12:58:24Z (GMT). No. of bitstreams: 1 Ademilson dos Santos Xavier_.pdf: 9916385 bytes, checksum: 8bcbfe8f2b36b5a58781ce2518c1bb83 (MD5) Previous issue date: 2016-10-13 / Nenhuma / Estudos recentes mostraram que uma grande parte da energia elétrica consumida no Brasil destina-se a edificações do setor Comercial e Público. Observando-se que o sistema de HVAC (Heating, Ventilation, and Air Conditioning) apresenta relevante papel no quadro final do consumo energético em edificações, a determinação de seus requisitos mínimos de eficiência energética torna-se o fator chave para o sucesso de qualquer programa de certificação energética em construções. Esse trabalho tem como objetivo avaliar de que forma as condições climatológicas brasileiras podem influenciar o desempenho de um sistema condicionador de ar com tecnologia VRF (Variable Refrigerant Flow) em Condições de Carga Parcial (Part Load Conditions), para uma edificação comercial. Para isso, foi desenvolvida uma metodologia capaz de identificar as localidades que foram objetos desse estudo. As cidades selecionadas foram: São Paulo (SP), Rio de Janeiro (RJ), Fortaleza (CE) e Brasília (DF). Após esta etapa, a caracterização do edifício modelo de referência (hotel) foi concretizada. Características físicas, valores de carga térmica externa e interna, e o perfil de uso (taxa de ocupação) da edificação, foram tópicos abordados. O software de simulação utilizado foi o EnergyPlus e as suas respectivas curvas e equações de desempenho foram ajustadas com base nos dados de performance dos aparelhos condicionadores de ar que foram selecionados. O fabricante Toshiba foi escolhido. A performance dos equipamentos VRF foi analisada através de resultados como Carga Térmica global, Condição de Carga Plena, Condições de Carga Parcial, PLR (Part Load Ratio), COP (Coefficient of Performance) e ICOP (Coeficiente Integrado de Performance). Os resultados mostraram que apesar da Condição de Carga Plena (Full Load Condition) ser recomendada para dimensionar o sistema de HVAC, quando o objetivo principal for avaliar o desempenho energético desse sistema (HVAC) para um período mais longo de operação essa análise deve ser realizada através das Condições de Carga Parcial (Part Load Conditions). Para as quatro localidades estudadas os valores de desempenho obtidos através das simulações mostram que os equipamentos de ar condicionado VRF utilizados atingiram o seu coeficiente máximo de performance (COPmáx) na condição de 50% de PLR e um ICOP de 6,8, contra um COP de 3,4 na condição nominal e um ICOP de 3,7 de acordo com o Regulamento Técnico da Qualidade do Nível de Eficiência Energética de Edifícios Comerciais, de Serviço e Públicos, RTQ-C. / Currently studies have been shown that a large part of the electricity consumed in Brazil is intended to buildings Commercial and Public Sector. The HVAC system (Heating, Ventilation, and Air Conditioning) shows a significant role in the final frame of the energy consumption in buildings, determining its minimum requirements for energy efficiency becomes the key factor for the success of any program energy certification of buildings. This work aims to analyze how the Brazilian climatic conditions can influence the performance of air conditioner systems with VRF technology (Variable Refrigerant Flow) in the Part-Load Condition for a commercial building. Therefore a methodology was developed to identify the locations that were the subject of this study. The cities selected are: São Paulo (SP), Rio de Janeiro (RJ), Fortaleza (CE) and Brasília (DF). In addition the building characteristics have completed, external and internal thermal load values with their use profile have been analyzed. The software applied was EnergyPlus and their performance curves and equations have been adjusted according with the performance data of air conditioning units selected. The manufacturer Toshiba has been chosen. The VRF equipment performance was analyzed through results as Full-Load Condition, Part-Load Conditions, Part Load Ratio (PLR), COP and COP (Integrated Coefficient of Performance). The main results have showed that despite the Full-Load Condition is recommended to dimension the HVAC system, when the objective is the evaluation of the energy performance for a longer operation period this analysis should be carried out through Part-Load Conditions. For all of the four cities have studied the performance values obtained from the simulations show that the air-conditioning equipment VRF used reached their maximum performance coefficient (COPmáx) at 50% of PLR and ICOP 6.8, against a COP 3.4 in nominal condition and ICOP of 3.72 according to the Quality Technical Regulation of the Energy Efficiency Level Commercial Buildings, and Public Service, RTQ-C.
6

Estudo do comportamento de materiais não convencionais utilizados como revestimento de paredes, visando à redução da carga térmica.

Sousa, Vívian Aparecida Lima 10 February 2012 (has links)
Made available in DSpace on 2015-05-08T14:53:20Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2371434 bytes, checksum: 9feb77190f039aa7f22992e3cc4e4ad9 (MD5) Previous issue date: 2012-02-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This dissertation studied the behavior thermal, physical and mechanical of mortar coatings composed of pure gypsum, plaster / EVA (ethylene-vinyl acetate copolymer) and gypsum / vermiculite applied on surfaces of building walls in order to reduce the thermal load on the walls consisted of conventional ceramic bricks and cement-sand mortar, taken as a reference. The objective was to obtain a material capable of reducing the thermal load and therefore the consumption of electrical energy used in air conditioning system for the thermal comfort of people and protection of equipment from the electrical substation of CHESF located in Milagres, in the semi-arid northeast of Brazil. The mortars were developed at the Laboratory for Testing Materials and Structures LABEME / UFPB, and underwent tests assessing their physical and mechanical properties. The result showed that the mortars have developed physical and mechanical properties that satisfy the standards in Brazil, being suitable the use of coating internal and external walls. Moreover, its application involves the reduction of non-degradable material released in nature, as the residue of EVA. The thermal conductivity of each mortar was obtained at the Laboratory of Porous Media and Thermophysical Properties LMPT UFSC-through flowmetric method. The mortar plaster, plaster / EVA and gypsum / vermiculite showed the thermal conductivity of 0.43 W / mK, 0.41 W / mK and 0.22 W / mK, respectively, behaving as thermal insulation. The results showed that the coating using mortar and plaster gypsum / EVA had a 18% reduction of thermal load of the environment on the wall by reference. And using the coating gypsum mortar / vermiculite this reduction reached 36%. / A presente dissertação estudou o compartamento térmico, físico e mecânico das argamassas de revestimentos compostas por gesso puro, gesso/EVA (ethylene-vinyl acetate copolymer) e gesso/vermiculita aplicadas nas superficies das paredes de edificação visando à redução da carga térmica relativamente às paredes convencionais constituídas de tijolos de cerâmica e argamassas de cimento-areia, tomadas como referência. O objetivo foi obter um material capaz de reduzir a carga térmica e, por conseguinte, o consumo da energia elétrica utilizada no sistema de ar condicionado para o conforto térmico das pessoas e a proteção dos equipamentos de uma subestação elétrica da CHESF localizada em Milagres, na região semi-arida do nordeste brasileiro. As argamassas foram desenvolvidas no Laboratório de Ensaio de Materiais e Estruturas LABEME/UFPB, onde foram submetidas a testes da avaliação de suas propriedades fisicas e mecânicas. O resultado mostrou que as argamassas desenvolvidas têm propriedades físicas e mecânicas que satisfazem às normas brasileiras, sendo adequedas ao uso de revestimento de paredes internos e externos. Além disso, sua aplicação implica a redução de material não degradável lançado na natureza, como o residuo de EVA. A condutividade térmica de cada argamassa foi obtida no Laboratório de Meios Porosos e Propriedades Termofisicas LMPT-UFSC, através do método fluxometrico. As argamassas de gesso, gesso/EVA e gesso/Vermiculita apresentaram as condutividades térmicas de 0,43 W/mK, 0,41 W/mK e 0,22 W/mK, respectivamente, comportando-se portando, como isolamentes térmicos. Os resultados mostraram que utilizando o revestimento da argamassa de gesso e de gesso/EVA tem-se uma redução de 18% de carga térmica do ambiente em relação à parede de referencia. E utilizando o revestimento da argamassa de gesso/vermiculita essa redução chega a 36% .
7

Implementação de protótipo de resfriador termoelétrico por efeito Peltier aplicado a dispositivos semicondutores de potência

Moraes, Thiago Finotti de 27 November 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In any electrical or electronic circuit, thermal energy is a quantity that is always present and generally must be considered in the specifications of any application. In many cases, the heat from the Joule effect, as well as from other internal and irreversible losses, represent the biggest share of maximum heat that a system can dissipate under normal operation. In Power Electronics, the study and application of semiconductor power switches are particularly important. Many solutions have been developed over the years aiming to mitigate electrical losses and heat built-up in semiconductor power switches. It is important to state that the current amount of research available to academics and the general public into thermal effects on semiconductor power switches is not as wide as that concerning the applications of those switches. It is remarkably reduced the amount of work concerning active cooling of semiconductor power switches and components, as well as concerning the behavior of semiconductor power switches and components under active cooling. Thus, there is a lack of studies aiming the investigation of the behavior of electric switches under different thermal loads. Because of this lack, this work is focused on a proposal of an equipment actively cools semiconductor power switches used in Power Electronics, particularly those usually found in switched mode power supplies. The main purpose of this work is to develop an equipment for being used on a lab bench based on Peltier technology that sets thermal action on semiconductor power switches, making possible the evaluation of the behavior of these switches under different thermal exposures and temperatures. Fist, the Peltier technology was investigated and, later on, a solution was developed allowing the usage of this technology on semiconductor power switches. A detailed description and the calculations of the developed thermoelectric system are presented. The results of this work are presented as a comparative study of the behavior and limits of performance of MOSFETs in DC-DC Boost converters under active cooling compared to traditional passive heat sinks. During active cooling the MOSFET was cooled below ambient temperature, assuring its external thermal safety. The experimental results confirm the operation as intended. The main confirmed advantages were greater dissipated power, increase of thermal margin and capacity of actively transferring heat to an overloaded area to another place. / Em qualquer circuito elétrico ou eletrônico, a energia térmica é uma grandeza que está sempre presente e em geral deve ser levada em conta nas especificações de qualquer aplicação. Em vários casos, o calor decorrente do efeito joule, bem como de outras perdas internas e irreversíveis, representam a parcela mais impactante da quantidade de calor limítrofe que um sistema consegue dissipar em operação normal. São de particular importância em Eletrônica de Potência o estudo e a aplicação de chaves semicondutoras. Várias soluções têm sido desenvolvidas ao longo dos anos no sentido de mitigar as perdas elétricas em chaves semicondutoras, bem como o aumento de temperatura nas mesmas durante operação. É importante frisar que atualmente a quantidade de pesquisas disponíveis ao público acadêmico e geral sobre os efeitos térmicos em chaves semicondutoras não é tão ampla quanto sobre as aplicações dessas chaves. É particularmente reduzida a quantidade de trabalhos ligados ao resfriamento ativo de chaves e componentes elétricos, assim como de trabalhos voltados ao comportamento de chaves e componentes mediante resfriamento ativo. Sendo assim, existe uma carência de estudos que objetivem a investigação do comportamento de chaves semicondutoras mediante distintas cargas térmicas. Diante desta carência, o foco deste trabalho é apresentar uma proposta de equipamento que atue termicamente, seja aquecendo ou resfriando, sobre chaves semicondutoras utilizadas em eletrônica de potência, particularmente aquelas comumente usadas em fontes elétricas chaveadas. O objetivo principal deste trabalho é desenvolver um equipamento para uso em bancada baseado na tecnologia Peltier que resfrie ativamente chaves semicondutoras, possibilitando a avaliação de comportamento das mesmas mediante diferente exposições térmicas e temperaturas. Primeiramente a tecnologia Peltier foi investigada e, posteriormente, foi desenvolvida uma solução que permite a utilização desta tecnologia em dispositivos semicondutores de distintos encapsulamentos. Uma descrição detalhada e os cálculos de dimensionamento do sistema termoelétrico desenvolvido são apresentados. Os resultados deste trabalho são apresentados em forma de estudo comparativo sobre o comportamento e limites de desempenho de MOSFETs em conversores CC-CC Boost mediante resfriamento ativo frente aos tradicionais dissipadores passivos. Durante resfriamento ativo o MOSFET foi resfriado à temperatura subambiente e constante, garantindo sua a segurança térmica relacionada à temperatura do encapsulamento. Os resultados experimentais confirmam a operação do protótipo conforme a proposta deste trabalho. As principais vantagens confirmadas foram maior potência dissipada, aumento da margem térmica e capacidade de transferir ativamente calor de uma área sobrecarregada para outro local. / Mestre em Ciências
8

Tela de sombreamento e pintura em telhados de modelos reduzidos de galpões avícolas

Gomes Filho, João Soares [UNESP] 21 September 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-09-21Bitstream added on 2014-06-13T18:45:24Z : No. of bitstreams: 1 gomesfilho_js_dr_jabo.pdf: 765540 bytes, checksum: 15848770f797f69a1af286f79d7dc8d4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Quatro experimentos foram conduzidos para avaliar o efeito do sombreamento artificial e da pintura dos telhados na melhoria do conforto térmico de modelos reduzidos simulando galpões avícolas. Em todos os experimentos foram utilizadas coberturas com telha de fibrocimento, novas, sem cimento amianto, com 4,0mm de espessura. O Experimento 1 foi realizado na Universidade Estadual do Maranhão (UEMA), câmpus de São Luís, onde foram testados cinco tipos de coberturas: 1- sem tela, sem pintura (STSP – controle); 2- com tela a 0,05m de altura da telha, sem pintura (CT5SP); 3- com tela a 0,05m de altura da telha, com pintura (CT5CP); 4- com tela a 0,08m de altura da telha, sem pintura (CT8SP) e 5- com tela a 0,08m de altura da telha, com pintura (CT8CP). Foram determinados o Índice de Temperatura de Globo Negro e Umidade (ITGU), a Carga Térmica de Radiação (CTR) e a Entalpia Específica (H). As colheitas das variáveis meteorológicas (temperaturas de globo negro, de bulbo seco, de bulbo úmido e velocidade do vento) foram realizadas durante 12 dias experimentais (04 a 15 de nov. de 2009) às 10:00, 12:00, 14:00 e 16:00 horas. O tipo de cobertura CT5SP foi o que apresentou os melhores valores para ITGUcorr (79,81) e H (78,84 KJ.Kg-1 de ar seco). O melhor resultado para CTRcorr foi apresentado pelo tratamento CT5CP (480,12 W.m-2). O Experimento 2 foi realizado na Universidade Estadual Paulista (UNESP), câmpus de Jaboticabal, onde foram testados os mesmos tipos de coberturas do Experimento 1. As colheitas e registro das variáveis meteorológicas foram realizadas por 40 dias (13 de fev. a 24 de mar. de 2010), nos mesmos horários do Experimento 1. O tipo cobertura que proporcionou menor resultado para o ITGU (83,86) e H (86,41 KJ.Kg-1 de ar seco) foi o CT8CP. A menor CTR (549,52 W.m-2) foi verificada na cobertura CT5CP. O Experimento 3 objetivou verificar o efeito de dois tipos de telas... / Four experiments were conducted to assess the effect of shading and painting of roofs improving thermal comfort in reduced models of poultry houses. In all the experiments were used with roofing cement tile, new, no asbestos cement, with 4.0 mm thick. The first experiment was conducted at the Universidade Estadual do Maranhão (UEMA), campus of São Luís, where were tested five types of coverage: 1 - no shading, no paint (STSP - control), 2 - with shading 0.05 m in height tile, unpainted (CT5SP) 3 - with shading 0.05 m in height tile with painting (CT5CP) 4 - with shading 0.08 m in height tile, unpainted (CT8SP) and 5 – with shading 0.08 m height of the tile with painting (CT8CP). Were evaluated the index of black globe temperature and humidity (BGTHI), the Heat Load (HL) and the specific enthalpy (H). The readings of meteorological variables (black globe temperature, dry bulb, wet bulb temperatures and wind speed) were measured during 12 experimental days (from nov. 4th to 15th, 2009) at 10:00, 12:00, 14: 00 and 16:00 hours. The type of coverage CT5SP had the lowest values for BGTHI (79,81) and H (78,84 KJ.Kg-1 dry air). The best result for CTRcorr (480,12 W.m-2) was presented by treatment CT5CP. The second experiment was conducted at Universidade Estadual Paulista (UNESP), campus of Jaboticabal, where were tested the same types of coverages of Experiment 1. The collection and recording of meteorological variables were performed for 40 days (from feb. 13th to 24th, 2010), at the same times of Experiment 1. The type coverage that provided smaller results for the BGTHI (83,86) and H (86,41 KJ.Kg-1 dry air) was CT8CP. The lower HL (549,52 W.m-2) was verified with the coverage CT5CP. The third experiment aimed at assessing the effect of two types of shading screens (50 and 80%) on the thermal comfort... (Complete abstract click electronic access below)

Page generated in 0.0699 seconds