Spelling suggestions: "subject:"canning electron microscopy"" "subject:"8canning electron microscopy""
171 |
Otimização do processo de usinagem de titânio com laser pulsado de neodímioALMEIDA, IVAN A. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:36Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:47Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
|
172 |
Fibras monocristalinas de tungstatos duplos de metais alcalinos e terras raras: um estudo de crescimento atraves da tecnica de micro--pulling-down / Alkali rare earth double tungstates single crystal fibers: A growth study by the micro-pulling down methodMORAES, JAIR R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:56Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:06/58686-1
|
173 |
Influencia da preparacao previa de amostras de aco AISI H 13 no comportamento a nitretacaoALMEIDA FILHO, AMERICO de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:26Z (GMT). No. of bitstreams: 1
06769.pdf: 4275325 bytes, checksum: f2158eb766fa7886249500f40de27cec (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares, IPEN-CNEN/SP / FAPESP:97/04424-5
|
174 |
Processamento e caracterização de aços sinterizados para uso em insertos de assentos de válvulas / Processing and characterization of sintered steel for use in valve seat insertsSANTOS, IGOR P. dos 24 February 2015 (has links)
Submitted by Maria Eneide de Souza Araujo (mearaujo@ipen.br) on 2015-02-24T18:32:53Z
No. of bitstreams: 0 / Made available in DSpace on 2015-02-24T18:32:53Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
175 |
Estudo da sinterização de vidros aluminossilicatos por calorimetria exploratória diferencial / Evaluation of aluminossilicate glass sintering during differential scanning calorimetrySOUZA, JULIANA P. de 14 April 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-04-14T11:38:02Z
No. of bitstreams: 0 / Made available in DSpace on 2015-04-14T11:38:02Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
176 |
Estudo dos parâmetros de estabilidade de travamento entre implante dentário e componente protético através do sistema cone Morse / Study on the stability parameters of locking between dental implants and prosthetic component system through the Morse taperARANHA, LUIS C. 28 October 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-10-28T11:29:54Z
No. of bitstreams: 0 / Made available in DSpace on 2015-10-28T11:29:54Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
177 |
Strain rate dependent behavior of composite materials and epoxy / Comportamento dependente da ração de deformação de materiais compósitos e epóxiHernandez Baltodano, Dany Arnoldo [UNESP] 15 March 2017 (has links)
Submitted by DANY ARNOLDO HERNÁNDEZ BALTODANO (danyhdzb@hotmail.com) on 2017-04-18T19:13:44Z
No. of bitstreams: 1
Thesis Dany Hernandez.pdf: 2171039 bytes, checksum: 8f2efded7710ccbd5aed9274952116a7 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-04-18T20:27:33Z (GMT) No. of bitstreams: 1
hernandezbaltodano_da_me_bauru.pdf: 2171039 bytes, checksum: 8f2efded7710ccbd5aed9274952116a7 (MD5) / Made available in DSpace on 2017-04-18T20:27:33Z (GMT). No. of bitstreams: 1
hernandezbaltodano_da_me_bauru.pdf: 2171039 bytes, checksum: 8f2efded7710ccbd5aed9274952116a7 (MD5)
Previous issue date: 2017-03-15 / Outra / Considerando as amplas aplicações de materiais compósitos para melhorar estruturas de obras em engenharia, é importante estudar a dependência do comportamento do material em função da velocidade de deformação aplicada aos materiais compósitos e aos epóxis adesivos. Propriedades mecânicas do material Sikacarbodur S512 e materiais adesivos mostram comportamentos diferentes quando analisados utilizando diferentes razões de deformação. Os resultados obtidos mostram que o Sikacarbodur S512 não é um material dúctil devido à ausência de capacidade de experimentar deformações inelásticas porque o domínio elástico domina seu comportamento mecânico. Os aditivos epóxis não têm domínio plástico considerável, e o intervalo visco elástico domina o seu comportamento mecânico sob forças de tração. As análises de microscopia eletrônica de varredura (MEV) das amostras de Sikacarbodur S512 mostram que o comportamento de fratura acontece na zona de interface (zona de contato entre as fibras e a resina) que é afetada pela concentração de tensões e propagações de trincas. As análises de MEV antes e depois dos testes de tração das amostras de Sikadur 30 e Sikadur 330 mostram que ambos os materiais possuem uma fase contínua e uma fase granular. Nas duas resinas as ligações covalentes são quebradas durante os testes embora o Sikadur 30 tem o comportamento mais crítico. O Sikadur 330 tem melhor comportamento mecânico do que o sikadur 30 e esse melhor comportamento é mais bem entendido quando compara-se suas deformações de ruptura em tensão e suas capacidades para absorver energia. / Considering the wide application range of composite materials for retrofitting civil engineering structures, it is found important to study the strain rate dependent behavior of both composite materials and some structural adhesive epoxies. Mechanical properties of Sikacarbodur S512 and adhesives bonding materials show different behavior when analyzed at different strain rates. Moreover, it was found that Sikacarbodur S512 is not a ductile material since it cannot sustain inelastic deformation because an elastic range governs its mechanical behavior. Epoxies adhesive do not have a significant plastic range; a viscoelastic range governs their main mechanical behavior under tensile loads. Sikacarbodur S512 analyses using scanning electron microscopy (SEM) shows that the fracture behavior is addressed by the interphase zone (contact zone between fiber and resin) which is affected by tensile stress concentration and cracks propagations. SEM analyses before and after tensile tests of both Sikadur 30 and Sikadur 330 shows that they have a continuous phase and a granular phase. In both resins, covalent bonds are broken, however sikadur 30 shows the most critical behavior. Sikadur 330 has better mechanical behavior under uniaxial tensile test than sikadur 30, and this better behavior is realized when their tensile strain to break and absorbed energy capacity are compared.
|
178 |
Eficácia do cloridrato de tetraciclina na remoção da smear layer e na exposição do colágeno da matriz dentinária /Ishi, Eduardo de Paula. January 2007 (has links)
Orientador: Mirian Aparecida Onofre / Banca: Márcio Zaffalon Casati / Banca: Fabio André dos Santos / Banca: Carlos Rossa Júnior / Banca: José Eduardo Cezar Sampaio / Resumo: A remoção da smear layer e a exposição da matriz colágena da dentina de superfícies radiculares desprovidas de sua inserção conjuntiva tem o potencial de auxiliar o tratamento e/ou a regeneração periodontal. O objetivo deste estudo in vitro foi avaliar, por meio de microscopia eletrônica de varredura, a remoção da smear layer e a exposição da matriz colágena da dentina produzidas pela aplicação de cloridrato de tetraciclina (TTC-HCl). O cemento radicular das amostras foi removido com fresas diamantadas, processo seguido de raspagem e alisamento radicular com cureta. As 450 amostras foram divididas em 10 grupos: controle (soro fisiológico) e os que compreendiam a aplicação de TTCHCl nas concentrações: 10mg/ml, 25mg/ml, 50mg/ml, 75mg/ml, 100mg/ml, 125mg/ml, 150mg/ml, 200mg/ml e 250mg/ml. Todos os grupos receberam essa aplicação de diferentes formas (passiva, pincel e fricção) e em diferentes tempos (1, 2 e 3 minutos). A avaliação foi feita por um examinador treinado, calibrado e que não conhecia o grupo ao qual as amostras pertenciam, utilizando o índice de Sampaio (1999) modificado para este estudo. Os dados foram analisados pelos testes de Kruskal- Wallis e de Dunn. As concentrações de 50mg/mL e 75mg/mL aplicadas por fricção e por pincelamento foram as mais efetivas na remoção de smear layer e na exposição de colágeno. O modo de aplicação passivo mostrou-se inferior aos demais (p=0,0001) com relação aos mesmos parâmetros, assim como o tempo de aplicação de 1 minuto também foi inferior em relação aos demais (p=0,002). Concluiu-se que as concentrações de 50mg/mL e 75mg/mL aplicadas por pincelamento ou fricção durante 2 ou 3 minutos foram as mais efetivas. / Abstract: Smear layer removal and collagen fibers exposure may improve periodontal treatment and regeneration. This in vitro study assessed smear layer removal and collagen fibers exposure after application of tetracycline hydrochloride (TTC-HCl) on root surfaces by means of scanning electron microscopy. Root cementum was removed with diamond burs followed by scaling and root planning. Four hundred and fifty samples were divided into 10 groups: control (application of saline) and application of TTC-HCl 10mg/ml, 25mg/ml, 50mg/ml, 75mg/ml, 100mg/ml, 125mg/ml, 150mg/ml, 200mg/ml and 250mg/ml. The TTCHCl application was performed in all groups in 3 different ways (passive, brushing and burnishing) and in 3 different times (1, 2 and 3 minutes). A previously trained, calibrated and blind examiner evaluated the photomicrographs using the Sampaio index (1999) modified for this study. Statistical analysis was performed by Kruskal-Wallis and Dunn tests. The 50mg/mL and 75mg/mL concentrations applied by burnishing or brushing were the most effectives in smear layer removal and collagen fibers exposure. Both, the passive mode of application (p=0.0001) and 1-minute time of application (p=0,002) were the less effectives. In conclusion, the 50mg/mL and 75mg/mL concentrations applied by brushing or burnishing during 2 or 3 minutes were the most effectives. / Doutor
|
179 |
Estudo dos procedimentos utilizados para obtenção de microrretenções na superfície interna da porcelana : avaliação por meio de testes de rugosimetria e microscopia eletrônica de varredura /Porto, Thiago Soares. January 2006 (has links)
Orientador: Welingtom Dinelli / Co^orientador: / Banca: José Roberto Cury Saad / Banca: Mânio de Carvalho Tibúrcio / Resumo: O objetivo deste estudo foi avaliar a superfície interna de dois sistemas cerâmicos, após diferentes tratamentos de superfície, avaliação essa feita por meio de rugosimetria e microscopia eletrônica de varredura. Foram utilizadas as seguintes cerâmicas: IPS Empress II (Ivoclar-Vivadent Alemanha) e InCeram Alumina (Vita Zahnfabrick - Alemanha). Foram confeccionadas 50 amostras em forma de pastilha para cada sistema cerâmico de acordo com as especificações dos fabricantes, armazenadas à temperatura ambiente para então serem submetidas ao tratamento superficial, a saber (n=10): sem tratamento (T0) (controle); Ácido fluorídrico (T1); Ácido fluorídrico associado ao jato de óxido de alumínio (T2); Sistema Cojet (T3); Laser Nd:YAG (T4). Para os resultados de rugosidade, padronizaram-se as medidas em Ra, sendo posteriormente realizada a análise estatística por meio de ANOVA e teste de Tukey (p<.001). Para ambos os grupos controle (T0) das cerâmicas testadas, as análises evidenciaram os valores de rugosidade mais inferiores; para o Sistema InCeram Alumina, os tratamentos, ácido fluorídrico (T1), Sistem Cojet (T3)e Laser Nd:YAG (T4), não tiveram diferença estatisticamente significante; já para o Sistema IPS Empress II, todos os tratamentos foram estatisticamente diferentes. As fotomicrografias em microscopia eletrônica de varredura mostraram características diferentes para os tratamentos peculiares para cada sistema cerâmico. Baseado nos dados obtidos pode-se concluir que, quanto ao IPS Empress II, o tratamento com ácido fluorídrico é suficiente, assim como o Sistema CoJet é para o InCeram Alumina. Outros estudos devem ser realizados para que se tenham parâmetros ideais para o tratamento a laser. / Abstract: The present study aimed at evaluating the inner surface of two ceramic systems, after different surface treatments, performed by surface roughness tests and scanning electron microscopy (SEM). IPS Empress II (Ivoclar-Vivadent - Germany) and InCeram Alumina (Vita Zahnfabrick - Germany) were used. Fifty lozenge-shaped samples were made for each ceramic system according to the manufacturers' specifications, and stored at room temperature prior to surface treatment; namely (n=10): non-treated (T0) (control); hydrofluoric acid (T1); hydrofluoric acid associated to airborne particle abrasion (T2); CoJet System (T3); Laser Nd: YAG (T4). Roughness measurement results were standardized in Ra. Analysis of variance (ANOVA) and Tukey test (p<.001) were used to perform the stastistics analysis. For both control groups of the tested ceramics, analyses revealed the lowest roughness values; for the InCeram Alumina System, treatments such as hydrofluoric acid (T1), CoJet System (T3) and Laser Nd:YAG (T4) did not present any statistically significant difference, while for the IPS Empress II System, all treatments were statistically different. Photomicrographs by SEM showed different characteristics for each ceramic system treatment. Based on the resulting data, it can be concluded that the hydrofluoric acid treatment suits the IPS Empress II System, as well as the CoJet System suits the InCeram Alumina System. Further research might be done in order to get ideal parameters for the laser treatment. / Mestre
|
180 |
Análise da microfenda axial em cavidades classe V restauradas com resina composta e polimerizadas com diferentes fontes de luz. Estudo pela microscopia eletrônica de varredura /Magnani, Cristina. January 2002 (has links)
Resumo: Um dos maiores problemas das restaurações de resinas compostas é a sua contração durante a polimerização, causando fendas entre as paredes cavitárias e o material restaurador. Assim, este trabalho teve como objetivo avaliar a influência da fonte de luz polimerizadora na formação de fendas axiais em restaurações classe V de dois tipos de resina composta. Foram utilizados 80 molares humanos, nos quais foram realizados os preparos cavitários com: 2mm de profundidade, 2mm de extensão ocluso-cervical e 2mm de extensão mésio-distal. Foram confeccionadas duas restaurações em cada dente (uma na superfície vestibular e outra na lingual) restauradas com dois tipos de resinas compostas: micropartículas (Filtek A110, cor A3 - 3M) e híbrida (Filtek P60, cor A3 - 3M); utilizando o sistema adesivo Prime & Bond NT (Dentisply), para um total de 160 amostras. Essas amostras foram divididas em 8 grupos, variando-se a fonte de luz e o tempo utilizado para a fotopolimerização do material: Grupo 1: resina micropartículas + aparelho convencional - 40s; Grupo 2: resina híbrida + aparelho convencional - 40s; Grupo 3: resina micropartículas + laser de argônio - 20s; Grupo 4: resina híbrida + laser de argônio - 20s; Grupo 5: resina micropartículas + diodo emissor de Luz (LED) azul- 40s; Grupo 6: resina híbrida + LED azul- 40s; Grupo 7: resina micropartículas + LED azul- 60s; Grupo 8: resina híbrida + LED azul- 60s. Os dentes foram armazenados em água destilada por 7 dias e submetidos à ciclagem térmica. A análise das medidas de fenda, quando presente, foi realizada através de microscopia eletrônica de varredura pela técnica de réplica, e os resultados obtidos foram submetidos a análise estatística de variância e teste de Tukey ao nível de 5% de significância. Concluiu-se que a resina de micropartículas apresenta maior contração de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: One of the greatest problems of restorations with composite resin is its contraction during light-curing, casing gaps between the cavitary walls and the restorative material. Thus, this study had as main goal to evaluate the influence of the light source light-cured on the formation of axial gaps in class V restorations of two types of composite resin. Eighty (80) human molars were used, in which cavitary preparations were accomplished with: 2mm of depth, 2mm of occlusocervical extension and 2mm of mesiodistal extension. Two restorations in each tooth were restored (one in the vestibular surface and the other on the lingual surface) with two types of composite resin: microparticles (Filtek A110, color A3 - 3M) and hybrid (Filtek P60, color A3 - 3M); using the adhesive system Prime & Bond NT (Dentisply), on a total of 160 samples. These samples were divided into eight groups, varying the light source and the time used for the material light-curing: Group 1: microparticles resin + conventional appliance - 40 s; Group 2: hybrid resin + conventional appliance - 40 s; Group 3: microparticles resin + argon laser - 20 s; Group 4: hybrid resin + argon laser - 20 s; Group 5: microparticle resin + light emitting diodes (LEDs) blue - 40 s; Group 6: hybrid resin + blue LEDs - 40 s; Group 7: microparticles resin + blue LEDs - 60 s; Group 8: hybrid resin + blue LEDs - 60 s. All teeth were storage in distilled water for 7 days and submitted to thermal cycling. The analysis of the gap measures, when present, was fulfilled by using the scanning electron microscope by the reproduction technique, and the results obtained were submitted to the statistical analysis of variance and the Tukey test to 5% significance level. It was concluded that the microparticles resin presents more light-curing contraction than the hybrid resin, independently... (Complete abstract, click electronic address below). / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Vanderlei Salvador Bagnato / Banca: Osmir Batista de Oliveira Júnior / Banca: Alberto Magno Gonçalves / Mestre
|
Page generated in 0.078 seconds