• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 16
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 49
  • 49
  • 49
  • 30
  • 20
  • 20
  • 17
  • 17
  • 16
  • 14
  • 12
  • 11
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Tratamento de esgoto sanitário em reatores anaeróbios operados em bateladas seqüenciais e periodicamente aerados / Treatment of domestic sewage in periodically aerated anaerobic sequencing batch reactors

Vela, Francisco José 17 March 2006 (has links)
O avanço da tecnologia anaeróbia para tratamento de esgotos deve ser creditado em grande parte ao desenvolvimento dos modernos reatores de alta taxa de aplicação orgânica, com os maiores méritos ao filtro anaeróbio ascendente e principalmente, à configuração do UASB. A evolução dos reatores levou à busca para maximizar a aplicação prática para aproveitar todas as potencialidades dos processos anaeróbios. Todas as modernas configurações têm em comum a preocupação em atender requisitos essenciais em um reator: formação e retenção de grande quantidade de biomassa e melhoria do contato biomassa/matéria orgânica. Esta pesquisa tem como principal objetivo avaliar dois reatores anaeróbios, operados em batelada seqüencial e periodicamente aerados, como unidade de tratamento das águas residuárias geradas no campus da Universidade de São Paulo em São Carlos. Um dos reatores contém biomassa imobilizada em espuma de poliuretano e o outro é operado com biomassa suspensa ou auto-imobilizada, sem utilização de suporte inerte. Os sistemas, na primeira etapa operacional, anaeróbia, apresentaram remoção de matéria orgânica, com eficiências médias para espuma de 61% (ASBBR) e grânulos de 56% (ASBR) e eficiências na remoção de sólidos iguais a 62% de SST e 65% de SSV no ASBBR e 56 % de SST e 61% de SSV no ASBR. Na segunda etapa operacional, anaeróbia e aeróbia, os reatores ASBR e ASBBR, mostrou que a estratégia de operação com etapa anaeróbia seguida por período com aeração não foi adequada para remoções de matéria orgânica e nitrogênio. Os reatores operaram com grande instabilidade e baixas eficiências de remoção de matéria orgânica, abaixo das observadas em reator operado de forma anaeróbia. / The advance of anaerobic technology for wastewater treatment should be credited in great part to the development of the modern reactors with high rates of organic application, with merit to the ascendant anaerobic filter and mainly to the UASB configuration. The evolution of reactors led to the search to maximize the practical aplication to make the best use of all the potentialities of the anaerobic processes. All the modern configurations have in common the preoccupation to deal with essential requisites in a reactor: formation and retention of a large quantity of biomass and improvement in the biomass/organic matter contact. This research prime objective is to evaluate two anaerobic reactors, operated in sequential batch and periodically aerated, as unity of treatment of wastewaters generated at the campus of the University of São Paulo in São Carlos. One of the reactors contains biomass immobilized on polyurethane foam and the other is operated with suspended or autoimmobilized biomass, without the use of inert support. The systems, in the first operational step, anaerobic, presented organic matter removal, with medium efficiencies for foam of 61% (ASBBR) and granule of 56% (ASBR) and efficiencies in the removal of solids equal to 62% of TSS and to 65% of VSS in the ASBBR and to 56% of TSS and to 61% of VSS in the ASBR. In the second operational step, anaerobic and aerobic, the ASBBR and ASBR reactors showed that the strategy of operation with anaerobic step followed by a period with aeration was not adequate for the removal of organic matter and nitrogen. The reactors operated with great instability and low efficiency of organic matter removal, with results below of the ones observed in a reactor operated in the anaerobic way.
22

Decantação acelerada: alternativa para o tratamento de vazão excedente de esgoto - estudo na ETE Martim de Sá (Caraguatatuba/SP). / Lamella sedimentation: alternative for treatment of overflow sewage - study in ETE Martim de Sá (Caraguatatuba/SP).

Gomes, Fernanda Cavalcante 12 April 2010 (has links)
Este estudo foi motivado pela necessidade de se tratar o excesso de vazão afluente às estações de tratamento de esgoto, que ocorre em dias de chuvas intensas. A hipótese central deste estudo é a de que a adoção de processo físico-químico para o tratamento de esgoto excedente diluído, pode ser vantajosa em relação ao aumento da capacidade com a ampliação dos sistemas exclusivamente biológicos. A pesquisa foi desenvolvida na ETE Martim de Sá da SABESP, localizada em Caraguatatuba/SP, onde o esgoto é tratado por lodos ativados em bateladas sequenciais. Estudou-se a variação da vazão de esgoto afluente na época de chuvas, bem como o funcionamento das bateladas. Além disso, foi avaliado o emprego da coagulação, floculação e sedimentação em decantador laminar para tratar o excesso de vazão com aplicação de sulfato de alumínio, cloreto férrico e polímero catiônico em uma estação piloto, após a realização de ensaios em escala de bancada em aparelho de Jar Test. O monitoramento da vazão afluente mostrou que em dias de chuvas e com ocorrência de desvios, a vazão máxima foi 220 L/s, ou seja, até 6 vezes maior que a vazão média de tempo seco. Para esta situação, o processo físico-químico pode tornar-se uma alternativa promissora, devido à sua capacidade de trabalho sob altas vazões em instalações de menor porte. Nos ensaios para se avaliar o tratamento físico-químico utilizou-se esgoto bruto pertencente a duas faixas de DBO: 50 e 100 mg/L e taxa de aplicação superficial no decantador de 76,82 m³ / m² / dia. A melhor dosagem de produto químico utilizada para tratar o esgoto bruto da faixa de DBO igual a 50 mg/L foi 40mg/L de cloreto férrico mais 0,5mg/L de polímero catiônico resultando em efluentes com DBO média de 26mg/L. Para o esgoto bruto da faixa de DBO igual a 100 mg/L a melhor dosagem foi a de 60mg/L de cloreto férrico, com DBO média dos efluentes igual a 44mg/L. Para esta faixa de trabalho é recomendável prever a aplicação de polímero. Por esta pesquisa concluiu-se que é possível atender aos limites legais de qualidade do esgoto tratado com o emprego do tratamento físico-químico, além disso produziu elementos importantes para subsidiar a avaliação econômica para a implantação desta tecnologia em paralelo ao sistema de lodo ativado nas situações de sobrecarga hidráulica. No entanto, a análise do fluxograma do funcionamento da estação com o processo de lodos ativado em bateladas, indicou que é possível efetuar o tratamento da vazão de 220 L/s pelo processo biológico. Assim, é recomendável a implantação do tratamento físico-químico somente se, após a realização do teste em escala real do funcionamento das bateladas com a vazão de 220 L/s, o tratamento biológico não atender aos padrões estabelecidos. / This study was motivated by the need to treat high wastewater influent exceeding in sewage treatment plants, which occurs on days of heavy rain. The central hypothesis of this study is that the physical-chemical process to treat dilute sewage overflow, it can be advantageous with respect to increased capacity and expansion of biological systems. The research was conducted in ETE Martim de Sá (SABESP), located in Caraguatatuba / SP, where the sewage is treated by sequencing batch reactor. It was studied the variation of the flow of wastewater during the rainy season, and the operation of the batch. Furthermore, it was evaluated the use of coagulation, flocculation and sedimentation in plate settler with application of aluminium sulfate, ferric chloride and cationic polymer in a pilot plant, after the testing of bench scale apparatus in Jar Test. Monitoring the inflow showed that on days of rainfall and bypass, the maximum flow was 220 L/s, up to 6 times the dry weather average flow. For this situation, the physico-chemical process may become a promising alternative, due to its ability to work under high flow rates in smaller facilities. In tests to evaluate the physical-chemical treatment was used two kinds of raw sewage: 50 and 100 mg/L BOD, overflow rate used in the plated settling tank was 76.82 m³/m² / day. The best dosage of chemical used to treat the raw sewage BOD of 50 mg/L was 40 mg/L ferric chloride plus 0.5 mg/L of cationic polymer, resulting in average effluent with BOD of 26 mg/L. For the raw sewage of the range BOD of 100 mg/L, 60 mg/L ferric chloride was the best dosage with an average BOD of effluent equal to 44 mg/L. For this range of work is recommended to provide for the application of polymer. This research concluded that it is possible to comply with the legal standard of treated sewage with physical-chemical treatment, also produced evidence that can help in the economic evaluation for the implementation of this technology in parallel with the activated sludge system in hydraulic overload situations. However, analysis of the flow diagram of operation of the station with the sequencing batch reactor, indicated that it is possible to make the treatment of flow of 220 L/s by the biological process. Therefore, is recommend the implementation of physical-chemical treatment only if after the test-scale operation of the batches with the flow rate of 220 L/s, the biological treatment doesn\'t meet the established standards.
23

Desempenho de reatores anaeróbios operados em bateladas sequenciais em escala piloto no tratamento de esgoto sanitário / The performance of anaerobic sequencing batch reactors in pilot scale for domestic sewage treatment

Sarti, Arnaldo 19 February 2004 (has links)
Este trabalho apresenta e discute os resultados obtidos na operação de quatro reatores anaeróbios operados em bateladas seqüenciais, projetados em escala piloto, para tratamento de 7,8 m3.dia-1 de esgotos sanitários, coletados da rede coletora que atravessa o Campus da USP de São Carlos. Cada sistema (1,2 m3) foi concebido para tratamento de 1,95 m3.dia-1 de esgoto sanitário, com concepções geométricas (relação L-altura/D-diâmetro), mecânicas (agitação mecânica ou recirculação de líquido) e tipo de retenção de biomassa diferentes. Três unidades eram do tipo ASBR (anaerobic sequencing batch reactor) e outro tipo ASBBR (anaerobic sequencing batch biofilm reactor) com leito fixo composto de matrizes cúbicas de espuma de poliuretano. Os ciclos operacionais tinham duração de oito horas perfazendo no total três ciclos por dia em cada sistema. O monitoramento dos reatores incluiu a determinação de DQO, pH, sólidos em suspensão totais (SST) e voláteis, ácidos voláteis totais, alcalinidade no afluente e efluente, bem como a concentração de metano no biogás. O ensaio experimental foi dividido em duas etapas distintas, sendo que na primeira (227 dias), os reatores não receberam inóculo e na segunda (66 dias) houve a inoculação prévia de lodo anaeróbio granular. Em ambas etapas, os dois reatores ASBR com mesmo tipo de agitação por recirculação de líquido, mas com diferente relação L/D não apresentaram desempenho satisfatório. Os valores médios de eficiência de remoção de DQO e de SST foram próximos de 40% e 60%, respectivamente. No efluente a concentração média foi de 300 mgDQO/L e de 100 mgSST/L. Nos reatores, ASBR com agitação mecânica e, ASBBR com biomassa imobilizada, os resultados médios obtidos foram melhores. O reator ASBBR atingiu eficiência média de 65% e 75% em remoção de DQO e SST, enquanto no ASBR com agitação mecânica chegou-se a 60% e 85%, respectivamente. A concentração média no efluente dos reator foi de 150 mgDQO/L e 60 mgSST/L no ASBBR e 220 mgDQO/L e 50 mgSST/L no ASBR com agitação mecânica. / This study reports and discuss several data obtained using four pilot scale anaerobic sequencing batch reactor, treating 7.8 m3.d-1 of domestic sewage from the Sao Paulo University sewer treatment system (Campus- São Carlos). Each reactor system (1.2 m3) was designed for the treatment of 1.95 m3.d-1 of domestic sewage with different geometric reactor characteristics (ratio L-length/D-diameter), mechanical (mechanical mixing or liquor re-circulation) and biomass retention type. Three reactors were a conventional ASBR (anaerobic sequencing batch reactor) with granular biomass and another one, an anaerobic sequencing batch biofilm reactor (ASBBR), which was composed with cubic matrices of polyurethane foam. The reactors were operated within 8-h of a sequential batch cycle, which were attained in three cycles by day for each system. Chemical oxygen demand (COD), pH, total suspended solids (TSS), volatile fatty acids, bicarbonate alkalinity in both the influent and effluent were monitored in the different cycles. Methane concentration was also assessed in the same period using Gas Chromatography (GC). The experiments were divided in two different phases. In the first phase, which corresponded to 227 d, the reactors were not inoculated. In the second phase (66 d) the reactors were then inoculated with anaerobic granular sludge. It was observed that in both operational phases, the two ASBR reactors, with the same re-circulating process of the mixed liquor, but with different L/D ratio, showed non-satisfactory results. The average values of COD and TSS removal were close to 40 and 60%, respectively. In the effluent, the average values were of 300 mgDQO/L and 100 mgTSS/L. ASBR reactors with mechanical mixing and ASBBR reactor with immobilized biomass showed better results. The average removal efficiency observed was of 65 and 75% for COD and TSS, respectively. ASBR reactors with mechanical mixing reached the efficiency of 60 and 85% for COD and TSS removal. The average concentration in the effluent was of 150 mgDQO/L and 60 mgSST/l in the ASBBR reactor; and 220 mgCOD/L and 50 mgTSS/L in the ASBR reactor with mechanical mixing.
24

Definição do ciclo operacional de um reator seqüencial em batelada aeróbio (SBR) para tratamento de esgoto sanitário / Definition of the operational cycle of an aerobic sequencing batch reactor (SBR) for the treatment of sanitary sewage

Marconi, Rodrigo Gibbin 19 January 2001 (has links)
No processo de lodos ativados por batelada, a definição de um ciclo operacional é de fundamental importância para o bom funcionamento de uma estação de tratamento de esgotos que utiliza esse tipo de tratamento. A adoção de um ciclo adequado pode trazer vários benefícios como o aumento da eficiência de tratamento, a introdução da remoção da matéria nitrogenada, por meio dos processos de nitrificação e desnitrificação do efluente e até diminuir o consumo de energia que é relativamente alto nesse tipo de tratamento. Foi aplicada então, a definição do ciclo operacional à ETE Bueno de Andrada que utiliza o processo de lodos ativados por batelada aeróbio para o tratamento da fase líquida. Foram experimentados alguns ciclos de operação com tempos e estratégias diferentes, variando-se os tempos de aeração, mistura, enchimento ou sedimentação. A aplicabilidade de cada estratégia de ciclo foi avaliada em termos da eficiência de remoção da matéria orgânica carbonácea, retratada com as análises de DBO e DQO do esgoto afluente e do efluente final. Foi desenvolvido também, o processo de automação da ETE Bueno de Andrada com o estudo e ajuste de um programa computacional que gera um arquivo de controle utilizado para controle do ciclo de operação dos SBRs. Os resultados mostraram que os ciclos operacionais entre 10 e 12h, consegue-se uma eficiência de remoção da matéria orgânica carbonácea entre 95 e 97%. / The definition of an adequate operational cycle for the batch activated sludge process is of fundamental importance for the proper operation of a sewage treatment plant. The use of a suitable cycle can bring many benefits namely the increase of the treatment efficiency, the introduction of the nitrogen organic material removal through the nitrification and denitrification process of the eflluent and the decrease of energy consumption that is relatively high in this process. The operational cycle definition is then applied to the Sewage Treatment Plant of Bueno de Andrada that use the aerobic batch activated sludge process for the liquid phase treatment. Some operational cycles are experimented with different times and strategies, changing the aeration, rnixture, filling or sedimentation times. The applicability of each cycle strategy was checked by the carbon organic material removal efficiency, measured through the BOD and COD analyses of the influent sewage and the treated eflluent. It was developed, too, the automation process of the Sewage Treatment Plant of Bueno de Andrada, cornplementing and adjusting the control computer program for the PLC that controls the SBRs operational cycle. The results showed that with operational cycles between 10 and 12 hours, the removal efficiency of the carbon organic material was between 95 and 97%.
25

Pós-tratamento por lodos ativados de efluente de um reator anaeróbio compartimentado no tratamento de esgoto sanitário / Post-treatment by activated sludge of anaerobic baffled reactor effluent in the treatment of sanitary sewage

Coletti, Fábio José 15 December 1997 (has links)
Estudou-se nesta pesquisa o processo de lodos ativados para pós-tratamento do efluente proveniente de um reator anaeróbio compartimentado, que recebe esgoto sanitário. Isso se deu em vários ensaios em sistema descontínuo (\"batch\'\') para avaliar a biodegradabilidade dessa água residuária e em um ensaio em sistema contínuo com finalidade de melhorar a qualidade do efluente final e determinar os coeficientes cinéticos, os parâmetros a\' e b \', a taxa de utilização de oxigênio e o coeficiente &#945. Também realizaram-se ensaios hidrodinâmicos para verificação do tipo de reator utilizado. A pesquisa desenvolveu-se com base em uma célula de aeração, em escala de laboratório, composta por quatro câmaras (reatores) que possuíam tanque de aeração e decantador secundário justapostos, separados por uma cortina fixa. Não houve controle de temperatura nos dois sistemas utilizados. No ensaio em sistema contínuo quatro reatores foram operados simultaneamente com as respectivas idades do lodo de 5, 10, 15 e 20 dias durante 35 dias. O tempo de detenção hidráulico foi mantido próximo de 8 horas. Nesse ensaio os reatores quando se encontravam estabilizados dinamicamente, apresentaram remoção superior a 95% para DBO bruta, 90% para DBO filtrada, 87% para DQO bruta, 80% para DQO filtrada e 95% para SST. Mesmo não sendo realizado processo adicional para remoção de nutrientes, os reatores, após a estabilização dinâmica, apresentaram remoção de fosfato de até 28% e de nitrogênio amoniacal até níveis de não serem detectados pelos métodos de análises utilizados. Os ensaios hidrodinâmicos mostraram que os reatores são do tipo mistura completa. / In this work the activated sludge process for post-treatment of effluent anaerobic baffled reactor which receives sanitary sewage was studied. This was established during various experiments in batch system to evaluate the biodegradable of this wastewater and also in an experiment of continuous system aiming to improve the quality of the final effluent and to determine the kinetic coefficients, the a\' and b\' parameters, the oxygen uptake rate and the &#945 coefficient. Hydrodynamic tests to verify the type of reactor used in this research were also perfonned. The work was developed and based on an aeration cell bench-scale, composed of four chambers (reactors) which had an aeration tank and a secondary settling tank in the same chamber, separated by a fixed baffle. Temperature control was not used in both systems. In the experiment of continuous system, four reactors were simultaneously operated with sludge age of 5, 10, 15 and 20 days during 35 days. The hidraulic retention time was maintained at around 8 hours. When the reactors were dynamically stabilized, they showed an average removal superior to 95% for BOD (biochemical oxygen demand), 90% for filtrated BOD, 87% for COD (chemical oxygen demand), 80% for filtrated COD and 95% for TSS (total suspended solids). Without additional process of nutrient removal, after the dynamic stabilization the reactors presented up to 28% of total phosphate removal and ammonia nitrogen up to levels of not being detected by the analyses methods used. The hydrodynamic tests showed that the reactors are of the complete-mix type.
26

Influência da estratégia de alimentação no desempenho do reator anaeróbio em batelada seqüencial contendo biomassa imobilizada / Influence of feeding strategy on the performance of anaerobic sequencing batch reactor containing immobilized biomass

Borges, Alisson Carraro 07 April 2003 (has links)
Submeteu-se um reator anaeróbio operado em batelada seqüencial a diferentes tempos de enchimento, com o objetivo de verificar-se o desempenho do sistema. O reator, construído em acrílico e com capacidade de 6,3 L, tratou por ciclo um volume de 2,5 L de esgoto sintético com concentração de aproximadamente 500 mgDQO/L. O sistema foi operado à temperatura de 30 graus mais ou menos 1, com duração de 8 h para cada ciclo (tC) e agitação de 500 rpm implementada mecanicamente. Cubos de espuma de poliuretano foram usados como suporte para imobilização da biomassa. No início de cada ciclo, o reator foi carregado com 60 % do volume do esgoto; o restante foi preenchido durante tempos de enchimento (tF) que caracterizaram as diferentes estratégias de alimentação. Os resultados obtidos demonstram que para razões tF/tC <= 0,5 o sistema alcança médias de remoção de matéria orgânica acima de 75 % e 70% para amostras filtradas e não filtradas, respectivamente. Nos ensaios em que tF/tC > 0,5, registrou-se perda na eficiência e formação de polímeros extracelulares, apesar da estabilidade observada. O estudo contribuiu para o melhor entendimento do sistema e definição de técnicas de operação em futuras aplicações. / An anaerobic sequencing batch reactor was operated at different fill times with the objective to asses system performance. The reactor, made of plexiglas and with a capacity of 6.3 L, treated per cycle 2.5 L of synthetic wastewater with a concentration of nearly 500 mgCOD/L. The system was operated at a temperature of 30oC, with 8-h cycles (tC) and mechanical agitation rate of 500 rpm. Cubic particles of polyurethane foam were used as support material for anaerobic biomass immobilization. At the start of each cycle, the reactor was fed with 60 % of the wastewater volume, the remainder was filled at different feeding times (tF) that characterized the different feeding strategies. The results obtained showed that for a ratio of tF/tC <= 0.5 the system attained average filtered and non-filtered substrate removal efficiency of 75 % and 70 %, respectively. Ratios of tF/tC > 0.5, resulted in loss in efficiency and formation of extra cellular polymers, in spite of system stability. The study contributed to a better understanding of the system and definition of operational techniques for future applications.
27

Influência do tipo de matéria orgânica no processo de desnitrificação em reatores seqüenciais em batelada / Influence of the organic matter type in the denitrification process in sequencing batch reactors

Oliveira, André Luiz de 26 October 2001 (has links)
Este trabalho apresenta o desempenho de um sistema de reatores seqüenciais em batelada aeróbio/anaeróbio, na remoção de matéria carbonácea (DQO) e nitrogenada, no tratamento de esgoto sanitário sintético, simulando esgoto doméstico. O sistema era composto por dois reatores dispostos em série, um aeróbio (RSBAe), responsável pela remoção de matéria carbonácea e nitrificação e outro, anaeróbio (RSBAn), responsável pela desnitrificação. Os reatores foram construídos em acrílico transparente, com volume total de 16,5 L e volume útil de 13,5 L. A operação dos reatores foi realizada com ciclos de 12h e 24h, na fase de adaptação, e de 24h, nas fases subseqüentes. O RSBAn foi agitado intermitentemente recirculando-se o biogás produzido e o RSBAe foi aerado/misturado continuamente. Foram testadas, como fontes de carbono para a desnitrificação, seis diferentes substratos, sendo que eram compostos por combinações dos constituintes do substrato sintético (variações percentuais de proteínas, carboidratos e lipídeos em termos de DQO), e as outras duas, metanol e etanol. A eficiência atingida, na remoção de DQO, foi em média de 95%, e as eficiências alcançadas na nitrificação e desnitrificação foram em média de 99%, para qualquer uma das fontes de carbono utilizadas. / This work presents the performance of (aerobic/anaerobic) sequencing batch reactors in the removal of carbonaceous (COD) and nitrogen matter treating synthetic substrate, simulating domestic wastewater. The system was composed of two reactors in series, one aerobic (RSBAe), responsible for the carbonaceous and nitrogen removal and another, anaerobic (RSBAn), responsible for denitrification. The reactors were built in transparent Plexiglas with total volume of 16,5 L and useful volume of 13,5 L. The reactors operation was carried out with cycles of 12h and 24h, in the adaptation phase, and 24h, in the other phases. The RSBAn were agitated intermittently by recycling the produced biogas and the RSBAe were aerated/agitated continuously. Six different subtracts were tested as carbon sources for denitrification four of them were composed by synthetic substrate combinations (percent variations of protein, carboidrates and lipids as COD) and the other two, methanol and ethanol. The COD removaI efficiency, in the COD removal, was about 95%, and the achieved efficiency in the nitrification and denitrification were about 99%, for any of the carbon source assayed.
28

Decantação acelerada: alternativa para o tratamento de vazão excedente de esgoto - estudo na ETE Martim de Sá (Caraguatatuba/SP). / Lamella sedimentation: alternative for treatment of overflow sewage - study in ETE Martim de Sá (Caraguatatuba/SP).

Fernanda Cavalcante Gomes 12 April 2010 (has links)
Este estudo foi motivado pela necessidade de se tratar o excesso de vazão afluente às estações de tratamento de esgoto, que ocorre em dias de chuvas intensas. A hipótese central deste estudo é a de que a adoção de processo físico-químico para o tratamento de esgoto excedente diluído, pode ser vantajosa em relação ao aumento da capacidade com a ampliação dos sistemas exclusivamente biológicos. A pesquisa foi desenvolvida na ETE Martim de Sá da SABESP, localizada em Caraguatatuba/SP, onde o esgoto é tratado por lodos ativados em bateladas sequenciais. Estudou-se a variação da vazão de esgoto afluente na época de chuvas, bem como o funcionamento das bateladas. Além disso, foi avaliado o emprego da coagulação, floculação e sedimentação em decantador laminar para tratar o excesso de vazão com aplicação de sulfato de alumínio, cloreto férrico e polímero catiônico em uma estação piloto, após a realização de ensaios em escala de bancada em aparelho de Jar Test. O monitoramento da vazão afluente mostrou que em dias de chuvas e com ocorrência de desvios, a vazão máxima foi 220 L/s, ou seja, até 6 vezes maior que a vazão média de tempo seco. Para esta situação, o processo físico-químico pode tornar-se uma alternativa promissora, devido à sua capacidade de trabalho sob altas vazões em instalações de menor porte. Nos ensaios para se avaliar o tratamento físico-químico utilizou-se esgoto bruto pertencente a duas faixas de DBO: 50 e 100 mg/L e taxa de aplicação superficial no decantador de 76,82 m³ / m² / dia. A melhor dosagem de produto químico utilizada para tratar o esgoto bruto da faixa de DBO igual a 50 mg/L foi 40mg/L de cloreto férrico mais 0,5mg/L de polímero catiônico resultando em efluentes com DBO média de 26mg/L. Para o esgoto bruto da faixa de DBO igual a 100 mg/L a melhor dosagem foi a de 60mg/L de cloreto férrico, com DBO média dos efluentes igual a 44mg/L. Para esta faixa de trabalho é recomendável prever a aplicação de polímero. Por esta pesquisa concluiu-se que é possível atender aos limites legais de qualidade do esgoto tratado com o emprego do tratamento físico-químico, além disso produziu elementos importantes para subsidiar a avaliação econômica para a implantação desta tecnologia em paralelo ao sistema de lodo ativado nas situações de sobrecarga hidráulica. No entanto, a análise do fluxograma do funcionamento da estação com o processo de lodos ativado em bateladas, indicou que é possível efetuar o tratamento da vazão de 220 L/s pelo processo biológico. Assim, é recomendável a implantação do tratamento físico-químico somente se, após a realização do teste em escala real do funcionamento das bateladas com a vazão de 220 L/s, o tratamento biológico não atender aos padrões estabelecidos. / This study was motivated by the need to treat high wastewater influent exceeding in sewage treatment plants, which occurs on days of heavy rain. The central hypothesis of this study is that the physical-chemical process to treat dilute sewage overflow, it can be advantageous with respect to increased capacity and expansion of biological systems. The research was conducted in ETE Martim de Sá (SABESP), located in Caraguatatuba / SP, where the sewage is treated by sequencing batch reactor. It was studied the variation of the flow of wastewater during the rainy season, and the operation of the batch. Furthermore, it was evaluated the use of coagulation, flocculation and sedimentation in plate settler with application of aluminium sulfate, ferric chloride and cationic polymer in a pilot plant, after the testing of bench scale apparatus in Jar Test. Monitoring the inflow showed that on days of rainfall and bypass, the maximum flow was 220 L/s, up to 6 times the dry weather average flow. For this situation, the physico-chemical process may become a promising alternative, due to its ability to work under high flow rates in smaller facilities. In tests to evaluate the physical-chemical treatment was used two kinds of raw sewage: 50 and 100 mg/L BOD, overflow rate used in the plated settling tank was 76.82 m³/m² / day. The best dosage of chemical used to treat the raw sewage BOD of 50 mg/L was 40 mg/L ferric chloride plus 0.5 mg/L of cationic polymer, resulting in average effluent with BOD of 26 mg/L. For the raw sewage of the range BOD of 100 mg/L, 60 mg/L ferric chloride was the best dosage with an average BOD of effluent equal to 44 mg/L. For this range of work is recommended to provide for the application of polymer. This research concluded that it is possible to comply with the legal standard of treated sewage with physical-chemical treatment, also produced evidence that can help in the economic evaluation for the implementation of this technology in parallel with the activated sludge system in hydraulic overload situations. However, analysis of the flow diagram of operation of the station with the sequencing batch reactor, indicated that it is possible to make the treatment of flow of 220 L/s by the biological process. Therefore, is recommend the implementation of physical-chemical treatment only if after the test-scale operation of the batches with the flow rate of 220 L/s, the biological treatment doesn\'t meet the established standards.
29

Desempenho de reatores anaeróbios operados em bateladas sequenciais em escala piloto no tratamento de esgoto sanitário / The performance of anaerobic sequencing batch reactors in pilot scale for domestic sewage treatment

Arnaldo Sarti 19 February 2004 (has links)
Este trabalho apresenta e discute os resultados obtidos na operação de quatro reatores anaeróbios operados em bateladas seqüenciais, projetados em escala piloto, para tratamento de 7,8 m3.dia-1 de esgotos sanitários, coletados da rede coletora que atravessa o Campus da USP de São Carlos. Cada sistema (1,2 m3) foi concebido para tratamento de 1,95 m3.dia-1 de esgoto sanitário, com concepções geométricas (relação L-altura/D-diâmetro), mecânicas (agitação mecânica ou recirculação de líquido) e tipo de retenção de biomassa diferentes. Três unidades eram do tipo ASBR (anaerobic sequencing batch reactor) e outro tipo ASBBR (anaerobic sequencing batch biofilm reactor) com leito fixo composto de matrizes cúbicas de espuma de poliuretano. Os ciclos operacionais tinham duração de oito horas perfazendo no total três ciclos por dia em cada sistema. O monitoramento dos reatores incluiu a determinação de DQO, pH, sólidos em suspensão totais (SST) e voláteis, ácidos voláteis totais, alcalinidade no afluente e efluente, bem como a concentração de metano no biogás. O ensaio experimental foi dividido em duas etapas distintas, sendo que na primeira (227 dias), os reatores não receberam inóculo e na segunda (66 dias) houve a inoculação prévia de lodo anaeróbio granular. Em ambas etapas, os dois reatores ASBR com mesmo tipo de agitação por recirculação de líquido, mas com diferente relação L/D não apresentaram desempenho satisfatório. Os valores médios de eficiência de remoção de DQO e de SST foram próximos de 40% e 60%, respectivamente. No efluente a concentração média foi de 300 mgDQO/L e de 100 mgSST/L. Nos reatores, ASBR com agitação mecânica e, ASBBR com biomassa imobilizada, os resultados médios obtidos foram melhores. O reator ASBBR atingiu eficiência média de 65% e 75% em remoção de DQO e SST, enquanto no ASBR com agitação mecânica chegou-se a 60% e 85%, respectivamente. A concentração média no efluente dos reator foi de 150 mgDQO/L e 60 mgSST/L no ASBBR e 220 mgDQO/L e 50 mgSST/L no ASBR com agitação mecânica. / This study reports and discuss several data obtained using four pilot scale anaerobic sequencing batch reactor, treating 7.8 m3.d-1 of domestic sewage from the Sao Paulo University sewer treatment system (Campus- São Carlos). Each reactor system (1.2 m3) was designed for the treatment of 1.95 m3.d-1 of domestic sewage with different geometric reactor characteristics (ratio L-length/D-diameter), mechanical (mechanical mixing or liquor re-circulation) and biomass retention type. Three reactors were a conventional ASBR (anaerobic sequencing batch reactor) with granular biomass and another one, an anaerobic sequencing batch biofilm reactor (ASBBR), which was composed with cubic matrices of polyurethane foam. The reactors were operated within 8-h of a sequential batch cycle, which were attained in three cycles by day for each system. Chemical oxygen demand (COD), pH, total suspended solids (TSS), volatile fatty acids, bicarbonate alkalinity in both the influent and effluent were monitored in the different cycles. Methane concentration was also assessed in the same period using Gas Chromatography (GC). The experiments were divided in two different phases. In the first phase, which corresponded to 227 d, the reactors were not inoculated. In the second phase (66 d) the reactors were then inoculated with anaerobic granular sludge. It was observed that in both operational phases, the two ASBR reactors, with the same re-circulating process of the mixed liquor, but with different L/D ratio, showed non-satisfactory results. The average values of COD and TSS removal were close to 40 and 60%, respectively. In the effluent, the average values were of 300 mgDQO/L and 100 mgTSS/L. ASBR reactors with mechanical mixing and ASBBR reactor with immobilized biomass showed better results. The average removal efficiency observed was of 65 and 75% for COD and TSS, respectively. ASBR reactors with mechanical mixing reached the efficiency of 60 and 85% for COD and TSS removal. The average concentration in the effluent was of 150 mgDQO/L and 60 mgSST/l in the ASBBR reactor; and 220 mgCOD/L and 50 mgTSS/L in the ASBR reactor with mechanical mixing.
30

Efeito da aeração e do tempo de ciclo na remoção biológica de nitrogênio de efluente da indústria avícola / Effect of aeration and cycle time in biological nitrogen removal of wastewater from poultry slaughterhouse

Lopes, Carla Limberger 01 July 2011 (has links)
Made available in DSpace on 2017-07-10T19:24:51Z (GMT). No. of bitstreams: 1 Carla Limberger Lopes_protegido.pdf: 1510356 bytes, checksum: 558cae02592904f9e836e71f9aa4036f (MD5) Previous issue date: 2011-07-01 / This study aimed to evaluate the influence of air flow (0.25, 0.50 and 0.75 L.min-1.Lreator-1) and cycle time (11.35 h, 15.15 h and 18.25 h) in the performance of a sequencing batch reactor (SBR) to promote nitrification and denitrification of wastewater from slaughterhouse's poultry and refrigerator. The operation included the steps of feeding, aerobic and anoxic reaction, sedimentation, discharge and rest. SBR was operated on a laboratory scale with a working volume of 4 L, keeping 25% of biomass retained in the reactor as an inoculum for the next batch. The "manipueira" was added as a carbon source at the beginning of anoxic phase in order to keep the C: N ratio between 5 and 6. During this process, parameters monitored included: pH, alkalinity, dissolved oxygen and temperature. It was developed a factorial design (22) with five repetitions at the central point to check the influence of the response variable removal of total inorganic nitrogen (NH4+-N + NO2--N + NO3--N) in the whole process (%). Data were analyzed with 95% confidence, and experimentally, a higher removal of total inorganic nitrogen (85.75%) on average was observed when using air flow of 0.50 L.min-1.Lreator-1 in time cycle of 15.15 h. However, there was no statistically significant factor for the air flow, and during the progress of study, this variable was kept stable at 0.25 L.min-1.Lreator-1 while the cycle time was gradually increased until efficiency in the removal of constant nitrogen could be observed, which occurred at time 15.1 h with 92.78% in removal efficiency of total inorganic nitrogen. / Esta pesquisa teve por objetivo avaliar a influência da vazão de ar (0,25, 0,50 e 0,75 L.min-1.Lreator-1) e do tempo de ciclo (11,35 h, 15,15 h e 18,25 h) no desempenho de um reator em bateladas sequenciais (RBS), em promover a nitrificação e a desnitrificação de água residuária de abatedouro e frigorífico de aves. A operação contemplou as etapas de alimentação, reação aerada e anóxica, sedimentação, descarte e repouso. O RBS foi operado em escala de laboratório com volume útil de 4 L, mantendo-se 25% da biomassa no reator, como inóculo para a próxima batelada. A manipueira foi adicionada como fonte de carbono no início da fase anóxica, de modo a manter a relação C:N entre 5 e 6. Durante o processo foram monitorados os parâmetros pH, alcalinidade, oxigênio dissolvido e temperatura. Elaborou-se um planejamento fatorial (22) com cinco repetições no ponto central para verificar a influência dos fatores na variável resposta remoção de nitrogênio inorgânico total (N-NH4++N-NO2-+N-NO3-) no processo completo (%). Os dados foram analisados com 95% de confiança e, experimentalmente, a maior remoção de nitrogênio inorgânico total (85,75%) em média foi observada quando se utilizou vazão ar de 0,50 L.min-1.Lreator-1, no tempo de ciclo de 15,15 h. Entretanto, não foi verificada significância estatística para o fator vazão de ar e, na continuidade do estudo, esta variável foi mantida estável em 0,25 L.min-1.Lreator-1, enquanto o tempo de ciclo foi gradativamente elevado até ser observada eficiência de remoção de nitrogênio constante, o que foi verificado a partir do tempo de 15,1 h com 92,78% na eficiência de remoção de nitrogênio inorgânico total.

Page generated in 0.0847 seconds