• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 50
  • 50
  • 47
  • 8
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 179
  • 67
  • 42
  • 35
  • 33
  • 30
  • 26
  • 24
  • 24
  • 19
  • 18
  • 17
  • 17
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

"The new order has arrived" Dutch Morial, reform, and the sewerage and water board of New Orleans, 1980-1981 /

Hardy, Eric M. January 2004 (has links)
Thesis (M.A.)--University of New Orleans, 2004. / Title from electronic submission form. "A thesis ... in partial fulfillment of the requirements for the degree of Master of Arts in the Department of History."--Thesis t.p. Vita. Includes bibliographical references.
42

Outfall monitoring in Hong Kong /

Lee, Hin-man, Arthur. January 1995 (has links)
Thesis (M. Sc.)--University of Hong Kong, 1995. / Includes bibliographical references (leaves 85-91).
43

EIA of sewerage projects : an overview of the Hong Kong situation /

Kan, Hon-shing. January 1995 (has links)
Thesis (M. Sc.)--University of Hong Kong, 1995. / Includes bibliographical references (leaves 52-55).
44

An analysis on the closing down of the sewage services trading fund in Drainage Services Department /

Lam, Wai-chuen, Eddie. January 1900 (has links)
Thesis (M.P.A.)--University of Hong Kong, 2000. / Includes bibliographical references (leaves 86-88).
45

An analysis on the closing down of the sewage services trading fund in Drainage Services Department

Lam, Wai-chuen, Eddie. January 1900 (has links)
Thesis (M.P.A.)--University of Hong Kong, 2000. / Includes bibliographical references (leaves 86-88). Also available in print.
46

Bactérias potencialmente resistentes a antibióticos, desinfetantes e radiação ultravioleta, isoladas de esgoto hospitalar e esgoto sanitário

Ferreira, João Cairo 09 April 2015 (has links)
CAPES / O uso da água e seu posterior lançamento em corpos hídricos, pode ser um possível fator de disseminação de microrganismos potencialmente patogênicos e/ou resistentes. A presença destes microrganismos em águas tratadas ou não, pode representar considerável risco a saúde da população em geral e ao meio ambiente. No Brasil, segundo a legislação atual, os estabelecimentos assistenciais de saúde podem direcionar seus efluentes para a rede coletora e de tratamento de esgoto, juntamente com o esgoto doméstico. Considerando a sobrevivência dos microrganismos patogênicos lançados no esgoto hospitalar e sua permanência após os processos de tratamento, buscou-se realizar a quantificação, isolamento, identificação de bactérias ambientais oportunistas e/ou feco-orais (Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa e Staphylococcus aureus), presentes em esgoto hospitalar, entrada e saída de uma estação tratamento de esgoto - ETE, além de estudar a sensibilidade destes isolados a antimicrobianos (antibióticos e desinfetantes) e exposição à radiação Ultravioleta (UV). Amostras de esgoto foram coletadas durante um período de oito meses (Maio a Dezembro de 2013), sendo realizadas analises quanto a seus parâmetros físico-químicos (DQO, Série de Sólidos, pH, Nitrogênio Amoniacal, Turbidez) e análises microbiológicas (Isolamento, quantificação e identificação), e testes de sensibilidade a antibióticos e desinfetantes mais utilizados nos hospitais brasileiros e de contatado com radiação ultravioleta. Foi constatado a existência de todos os gêneros/espécies foco deste estudo, em todos os pontos de coleta, além de resistência das bactérias aos antibióticos testados e tratamentos propostos. Um dos fatores de baixa eficiência para os tratamentos pode ser atribuída a quantidade elevada de sólidos suspensos dispersos no efluente e a crescente emergência de multirresistência para os testes de antibiograma. Estes fatores suscitam a necessidade de um maior controle pela comunidade científica e pela população em geral no que diz respeito ao impacto da presença dessas bactérias nos esgotos e posteriormente nos corpos hídricos, em seu ecossistema e a saúde pública. / The use of water and its posterior release into hydric bodies can be a possible factor of dissemination of microorganisms potentially pathogenic and/or resistant. The presence of these organisms in treated or untreated water may represent considerable threat to the general population’s health and the environment. In Brazil, according to current legislation, health assistance establishments can direct its effluents to the sewage treatment and collection network together with domestic sewage. Taking into consideration the survival of pathogenic microorganisms released in hospital sewage as well as its permanence after treatment processes, this study realized the quantification, isolation and identification of opportunistic environmental and/or fecal-oral bacteria (Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa e Staphylococcus aureus), present in hospital sewage and in sewage treatment station entry and exit –ETE, and studied the sensibility of these isolated towards antimicrobials (antibiotics and disinfectants) and exposure to UV (Ultraviolet Radiation). Sewage samples were collected during a period of 8 months (from May to December 2013) to analyze their chemical-physical parameters (COD, Series of Solids, pH, Nitrogen Ammonia, Turbidity) and to carry out microbiological analyses (Isolation, quantification and identification) and sensibility tests to the most used antibiotics and disinfectants by Brazilian hospitals and in contact with UV radiation. The presence of all the species/ genus, which were the focus of this study, was detected in all collection points plus their resistance to tested antibiotics and proposed treatments. One of the low efficiency factors for the treatments were the high amount of suspended solids dispersed in the effluent and the increasing multi-resistance emergency to antibiogram tests. These factors have created the need for greater control by the scientific community and the general population in regards to the impact of the presence of these bacteria in sewages and later in hydric bodies, its ecosystem and public health.
47

Reator de leito estruturado com recirculação submetido à aeração intermitente no tratamento de esgoto sanitário / Structured bed reactor with recirculation subjected to intermittent aeration in the treatment of domestic sewage

Correa, Camila Zoe 10 December 2015 (has links)
O lançamento de compostos nitrogenados em corpos d’água pode resultar em problemas ambientais, sendo assim tratar águas residuárias, como o esgoto sanitário com o objetivo de remover não apenas matéria orgânica, mas tambémnitrogênio tem sido objeto de estudo há algumas décadas. O objetivo deste trabalho foi avaliar o desempenho de um reator de leito estruturado e fluxo contínuo, com recirculação, na remoção de matéria orgânica e nitrogênio presente em esgoto sanitário, sob diferentes ciclos de Aeração intermitente (AI) e avaliar a influência destes ciclos no desenvolvimento de bactérias nitrificantes (Bactérias Oxidadoras de Amônia – BOA e Bactérias Oxidadoras de Nitrito – BON) e desnitrificantes (DESN) aderidas (Material Suporte - MS) e em suspensão (Efluente – EF e Lodo – LD). O reator utilizado possuía volume útil de 9,4 L. Como material suporte (MS) foi utilizado espuma de poliuretano, cortada e fixada em hastes de PVC. Foram trabalhadas 3 fases de aeração (AE) e não aeração (AN) com diferentes tempos: Fase 1 (4 h AE/ 2 h AN); Fase 2 (2 h AE/ 1 h AN) e Fase 3 (2 h AE/ 2 h AN). Durante todas as fases o tempo de detenção hidráulico foi mantido em 16 h e o efluente recirculado a uma vazão de 3 vezes a vazão afluente. Foram analisados: pH, alcalinidade total, temperatura, Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Nitrogênio Kjeldhl Total (NKT), N-amoniacal – N-NH4+, nitrito- N-NO2 e nitrato- N-NO3. A concentração das BOA, BON e DESN foi determinada utilizando o Número Mais Provável.gSSV-1 (NMP.gSSVmL-1). Na Fase 1 o percentual de remoção de NKT, N-NH4+ e NT foi de 76±10%, 70±21% e 67±10% respectivamente. Na Fase 2 de 80±15% de remoção de NKT, 86±15% de N-NH4+ e 68±9% de remoção de NT e na Fase 3 de 58±20%, 72±28% e 41±6% de NKT, N-NH4+ e NT, respectivamente. A eficiência de desnitrificação nas 3 fases foi acima de 70%, indicando que no reator ocorreu o processo de Nitrificação e desnitrificação Simultânea (NDS). Os percentuais de remoção de DQOT foram de 88%±4 na Fase 1, 94%±7 na Fase 2 e 90%±11 na Fase 3. A ANOVA multivariada aplicada ao NMP.gSSV-1, indicou que houve diferença significativa (F: 20,2; p-valor <0,01) entre a concentração dos organismos analisados nos diferentes ciclos de AI. Porém as diferenças entre os NMP.gSSV-1 não depende apenas de fatores isolados e sim de quais meios, fases e grupos estão sendo analisados. Dos resultados conclui-se que o sistema foi eficiente em termos de remoção de nitrogênio e matéria orgânica, e que a fase que apresentou a maior disponibilidade de Oxigênio Dissolvido (OD) e relação C/N (Fase 2), foi a que obteve as menores concentrações efluentes de matéria orgânica e N-NH4+. Apontasse que houve diferença significativa entre a concentração (NMP.gSSV-1) dos organismos analisados (BOA, BON e DESN), porém esta diferença não depende de fatores isolados e sim de quais meios (MS, EF ou LD, fases (1, 2 ou 3) e grupos (BOA, BON e DESN) está sendo considerado. / The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.
48

Bactérias potencialmente resistentes a antibióticos, desinfetantes e radiação ultravioleta, isoladas de esgoto hospitalar e esgoto sanitário

Ferreira, João Cairo 09 April 2015 (has links)
CAPES / O uso da água e seu posterior lançamento em corpos hídricos, pode ser um possível fator de disseminação de microrganismos potencialmente patogênicos e/ou resistentes. A presença destes microrganismos em águas tratadas ou não, pode representar considerável risco a saúde da população em geral e ao meio ambiente. No Brasil, segundo a legislação atual, os estabelecimentos assistenciais de saúde podem direcionar seus efluentes para a rede coletora e de tratamento de esgoto, juntamente com o esgoto doméstico. Considerando a sobrevivência dos microrganismos patogênicos lançados no esgoto hospitalar e sua permanência após os processos de tratamento, buscou-se realizar a quantificação, isolamento, identificação de bactérias ambientais oportunistas e/ou feco-orais (Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa e Staphylococcus aureus), presentes em esgoto hospitalar, entrada e saída de uma estação tratamento de esgoto - ETE, além de estudar a sensibilidade destes isolados a antimicrobianos (antibióticos e desinfetantes) e exposição à radiação Ultravioleta (UV). Amostras de esgoto foram coletadas durante um período de oito meses (Maio a Dezembro de 2013), sendo realizadas analises quanto a seus parâmetros físico-químicos (DQO, Série de Sólidos, pH, Nitrogênio Amoniacal, Turbidez) e análises microbiológicas (Isolamento, quantificação e identificação), e testes de sensibilidade a antibióticos e desinfetantes mais utilizados nos hospitais brasileiros e de contatado com radiação ultravioleta. Foi constatado a existência de todos os gêneros/espécies foco deste estudo, em todos os pontos de coleta, além de resistência das bactérias aos antibióticos testados e tratamentos propostos. Um dos fatores de baixa eficiência para os tratamentos pode ser atribuída a quantidade elevada de sólidos suspensos dispersos no efluente e a crescente emergência de multirresistência para os testes de antibiograma. Estes fatores suscitam a necessidade de um maior controle pela comunidade científica e pela população em geral no que diz respeito ao impacto da presença dessas bactérias nos esgotos e posteriormente nos corpos hídricos, em seu ecossistema e a saúde pública. / The use of water and its posterior release into hydric bodies can be a possible factor of dissemination of microorganisms potentially pathogenic and/or resistant. The presence of these organisms in treated or untreated water may represent considerable threat to the general population’s health and the environment. In Brazil, according to current legislation, health assistance establishments can direct its effluents to the sewage treatment and collection network together with domestic sewage. Taking into consideration the survival of pathogenic microorganisms released in hospital sewage as well as its permanence after treatment processes, this study realized the quantification, isolation and identification of opportunistic environmental and/or fecal-oral bacteria (Acinetobacter spp., Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa e Staphylococcus aureus), present in hospital sewage and in sewage treatment station entry and exit –ETE, and studied the sensibility of these isolated towards antimicrobials (antibiotics and disinfectants) and exposure to UV (Ultraviolet Radiation). Sewage samples were collected during a period of 8 months (from May to December 2013) to analyze their chemical-physical parameters (COD, Series of Solids, pH, Nitrogen Ammonia, Turbidity) and to carry out microbiological analyses (Isolation, quantification and identification) and sensibility tests to the most used antibiotics and disinfectants by Brazilian hospitals and in contact with UV radiation. The presence of all the species/ genus, which were the focus of this study, was detected in all collection points plus their resistance to tested antibiotics and proposed treatments. One of the low efficiency factors for the treatments were the high amount of suspended solids dispersed in the effluent and the increasing multi-resistance emergency to antibiogram tests. These factors have created the need for greater control by the scientific community and the general population in regards to the impact of the presence of these bacteria in sewages and later in hydric bodies, its ecosystem and public health.
49

Reator de leito estruturado com recirculação submetido à aeração intermitente no tratamento de esgoto sanitário / Structured bed reactor with recirculation subjected to intermittent aeration in the treatment of domestic sewage

Correa, Camila Zoe 10 December 2015 (has links)
O lançamento de compostos nitrogenados em corpos d’água pode resultar em problemas ambientais, sendo assim tratar águas residuárias, como o esgoto sanitário com o objetivo de remover não apenas matéria orgânica, mas tambémnitrogênio tem sido objeto de estudo há algumas décadas. O objetivo deste trabalho foi avaliar o desempenho de um reator de leito estruturado e fluxo contínuo, com recirculação, na remoção de matéria orgânica e nitrogênio presente em esgoto sanitário, sob diferentes ciclos de Aeração intermitente (AI) e avaliar a influência destes ciclos no desenvolvimento de bactérias nitrificantes (Bactérias Oxidadoras de Amônia – BOA e Bactérias Oxidadoras de Nitrito – BON) e desnitrificantes (DESN) aderidas (Material Suporte - MS) e em suspensão (Efluente – EF e Lodo – LD). O reator utilizado possuía volume útil de 9,4 L. Como material suporte (MS) foi utilizado espuma de poliuretano, cortada e fixada em hastes de PVC. Foram trabalhadas 3 fases de aeração (AE) e não aeração (AN) com diferentes tempos: Fase 1 (4 h AE/ 2 h AN); Fase 2 (2 h AE/ 1 h AN) e Fase 3 (2 h AE/ 2 h AN). Durante todas as fases o tempo de detenção hidráulico foi mantido em 16 h e o efluente recirculado a uma vazão de 3 vezes a vazão afluente. Foram analisados: pH, alcalinidade total, temperatura, Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Nitrogênio Kjeldhl Total (NKT), N-amoniacal – N-NH4+, nitrito- N-NO2 e nitrato- N-NO3. A concentração das BOA, BON e DESN foi determinada utilizando o Número Mais Provável.gSSV-1 (NMP.gSSVmL-1). Na Fase 1 o percentual de remoção de NKT, N-NH4+ e NT foi de 76±10%, 70±21% e 67±10% respectivamente. Na Fase 2 de 80±15% de remoção de NKT, 86±15% de N-NH4+ e 68±9% de remoção de NT e na Fase 3 de 58±20%, 72±28% e 41±6% de NKT, N-NH4+ e NT, respectivamente. A eficiência de desnitrificação nas 3 fases foi acima de 70%, indicando que no reator ocorreu o processo de Nitrificação e desnitrificação Simultânea (NDS). Os percentuais de remoção de DQOT foram de 88%±4 na Fase 1, 94%±7 na Fase 2 e 90%±11 na Fase 3. A ANOVA multivariada aplicada ao NMP.gSSV-1, indicou que houve diferença significativa (F: 20,2; p-valor <0,01) entre a concentração dos organismos analisados nos diferentes ciclos de AI. Porém as diferenças entre os NMP.gSSV-1 não depende apenas de fatores isolados e sim de quais meios, fases e grupos estão sendo analisados. Dos resultados conclui-se que o sistema foi eficiente em termos de remoção de nitrogênio e matéria orgânica, e que a fase que apresentou a maior disponibilidade de Oxigênio Dissolvido (OD) e relação C/N (Fase 2), foi a que obteve as menores concentrações efluentes de matéria orgânica e N-NH4+. Apontasse que houve diferença significativa entre a concentração (NMP.gSSV-1) dos organismos analisados (BOA, BON e DESN), porém esta diferença não depende de fatores isolados e sim de quais meios (MS, EF ou LD, fases (1, 2 ou 3) e grupos (BOA, BON e DESN) está sendo considerado. / The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.
50

Cryptosporidium spp., Giardia spp. e ovos de helmintos em esgoto hospitalar : destruição e analise de dano estrutural dos protozoarios apos o processo fotoeletroquimico / Cryptpsporidium spp., Giardia spp. and helminthes eggs in raw hospital sewerage : destruction and structural damage of protozoa after photoelectroschemical process

França, Rita Borges 29 June 2007 (has links)
Orientador: Regina Maura Bueno Franco / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-09T07:00:20Z (GMT). No. of bitstreams: 1 Franca_RitaBorges_M.pdf: 4952448 bytes, checksum: 49473f55f00ae94646a96bb8c6672aac (MD5) Previous issue date: 2007 / Resumo: O efluente hospitalar apresenta, dentre seus componentes, organismos como vírus, bactérias, protozoários e helmintos, que ocasionam muitas doenças com implicações em saúde pública. Cryptosporidium spp. e Giardia spp. são protozoários parasitos com grande importância por sua veiculação hídrica e cujas formas infectantes são resistentes aos processos rotineiramente usados no tratamento de água e esgoto. A transmissão destes pode ocorrer com a ingestão dos oocistos e cistos eventualmente presentes na água e nos alimentos contaminados, por contato direto (pessoa a pessoa), por contato indireto (objetos contaminados), pelo contato sexual ou pode ser zoonótica. Os métodos mais utilizados para desinfecção em estações de tratamento são a aeração, cloração e irradiação por UV, mas a cloração, não é suficiente para eliminar oocistos de Cryptosporidium spp e cistos de Giardia spp. A tecnologia eletroquímica oferece um meio de tratamento eficiente para a oxidação. da carga orgânica e microbiológica degradando-as ou mineralizando-as. O presente trabalho teve por objetivos: (1) verificar a ocorrência natural de Cryptosporidium spp. e Giardia spp. em amostras de esgoto do Hospital de Clínicas de Campinas, utilizando o método, de centrífugo-concentração seguido de clarificação com éter e visualização por, imunofluorescência direta, durante o período de um ano; (2) verificar a presença de ovos e larvas de helmintos no esgoto hospitalar empregando a técnica da NOM (Norma Oficial Mexicana) e (3) avaliar a taxa de destruição e o dano estrutural causado em cistos e oocistos após o tratamento fotoeletroquímico. No esgoto hospitalar bruto 4,1 % e 58,3 % das amostras foram positivas para Cryptosporidium spp. e Giardia spp., respectivamente, sendo observada a concentração média de 2,7 x 103 oocistos/L e 3,8 x 105 cistos/L. Foi possível verificar a elevada presença de helmintos, com 90 % das amostras apresentando positividade e concentração de 5,8 x 104 ovos/L e 4,0 x 105 larvas/L. Os protozoários e helmintos presentes em altas concentrações no esgoto hospitalar representam uma séria ameaça à saúde humana. Para os ensaios com o tratamento fotoeletroquímico, amostras de 1 L de esgoto hospitalar foram artificialmente contaminadas com cistos e oocistos e, posteriormente, submetidas a esse tratamento em um reator de bancada, com tempos de exposição de 0,30, 60 e 90 minutos. Por meio das técnicas de imunofluorescência direta, microscopia de contraste de fase e microscopia eletrônica de varredura verificou-se o dano estrutural causado pela ação dos radicais hidroxila nesses protozoários patogênicos e a destruição dos mesmos. O tratamento fotoeletroquímico mostrou uma redução na concentração dos protozoários nos tempos de 30 e 60 minutos e após 90 minutos, nenhum cisto ou oocisto foi detectado. A presença do cloreto no efluente bruto (média de 45 mg/l) desencadeou uma potencializaçáo da ação de mecanismo do reator, gerando efeito associado com a eletrólise, dos radicais hidroxila com a formação de hipoclorito / Abstract: Hospital effluent presents organisms as virus, bacteria, protozoan and helminthes, that cause many iIInesses with implications in public health. Cryptosporidium spp. and Giardia spp. are parasites with waterborne importance and its cysts and oocysts are resistant to the routinely processes used in water treatment. Their transmission can occur by oocysts and cysts ingestion in the water and contaminated foods, by direct contact (person the person), by indirect contact (contaminated objects), by sexual contact or zoonotic. The methods used for disinfection and treatment of sewage are aeration, chlorination and irradiation of ultraviolet light, but the treatment by chlorination is not enough to inactivate Cryptosporidium spp. oocyst and Giardia spp. cysts. The electrochemical technology offers an efficient treatment for the oxidation of organic and microbiological load, degrading and mineralizing them. The present work had as objectives: (1) to verify the natural occurrence of Cryptosporidium spp. and Giardia spp. in samples of Clinical Hospital sewage from Unicamp using centrifugal concentration followed by clarification with ether method and visualization by immunoflourescence assay, during one year, (2) to verify the presence of eggs and larvae of helminthes in the hospital sewage by NOM (Mexican Official Norm) technique and (3) to evaluate the destruction rate and the structural damage caused in cysts and oocysts by photoelectrochemical treatment. In raw hospital sewage 4.1 % and 58.3% of the samples were positive for Cryptosporidium spp. and Giardia spp., respectively, with concentrations of 2.7 x 103 oocysts/L and 3.8 x 105 cysts/L. The high presence of helminthes, 90% positive, with 5.8 x 104 eggs/L and 4.0 x 105 larvae/L and protozoan in hospital sewage represent a serious threat to human being health. For the assays with the photoelectrochemical treatment, samples of 1 L of hospital sewage artificially contaminated with cysts and oocysts ! were submitted to this treatment in a bench reactor, with times of exposition of 0, 30, 60 and 90 minutes. By the techniques of immunofluorescence assays, microscopy of phase contrast and scanning electronic microscopy, the structural damage and destruction were observed, caused by hydroxyl radicals in these pathogenic protozoans. The photoelectrochemical treatment showed a concentration reduction of the protozoan in 30 and 60 minutes, and after 90 minutes no cyst or oocysts were detected. The chloride present in raw effluent (average of 45 rng/L) unchained a potential action of the reactor mechanism, generating an effect associated with electrolysis of the hydroxyl radicals with production of hypochlorite / Mestrado / Parasitologia / Mestre em Parasitologia

Page generated in 0.0636 seconds