• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 106
  • 92
  • 34
  • 23
  • 16
  • 11
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 318
  • 81
  • 61
  • 40
  • 40
  • 38
  • 35
  • 33
  • 30
  • 30
  • 30
  • 30
  • 29
  • 27
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Constructing a Depth Map from Images

Ikeuchi, Katsushi 01 August 1983 (has links)
This paper describes two methods for constructing a depth map from images. Each method has two stages. First, one or more needle maps are determined using a pair of images. This process employs either the Marr-Poggio-Grimson stereo and shape-from-shading, or, instead, photometric stereo. Secondly, a depth map is constructed from the needle map or needle maps computed by the first stage. Both methods make use of an iterative relaxation method to obtain the final depth map.
92

The incorporation of bubbles into a computer graphics fluid simulation

Greenwood, Shannon Thomas 29 August 2005 (has links)
We present methods for incorporating bubbles into a photorealistc fluid simulation. Previous methods of fluid simulation in computer graphics do not include bubbles. Our system automatically creates bubbles, which are simulated on top of the fluid simulation. These bubbles are approximated by spheres and are rendered with the fluid to appear as one continuous surface. This enhances the overall realism of the appearance of a splashing fluid for computer graphics. Our methods leverage the particle level set representation of the fluid surface. We create bubbles from escaped marker particles from the outside to the inside. These marker particles might represent air that has been trapped within the fluid surface. Further, we detect when air is trapped in the fluid and create bubbles within this space. This gives the impression that the air pocket has become bubbles and is an inexpensive way to simulate the air trapped in air pockets. The results of the simulation are rendered with a raytracer that includes caustics. This allows the creation of photorealistic images. These images support our position that the simple addition of bubbles included in a fluid simulation creates results that are much more true to life.
93

Measurements and Models Related to Solar Optics in Windows with Shading Devices

Kotey, Nathan Amon 06 April 2009 (has links)
Shading devices have the potential to reduce peak cooling load and annual energy consumption because they can be used to control solar gain. Thus, the need to model shading devices in a glazing system analysis is important. This thesis deals with various measurement techniques and model development related to solar optics in windows with shading devices. It also considers longwave radiative properties of shading devices via model development and experimentation. The different shading devices examined were roller blinds, insect screens, pleated drapes and venetian blinds. The energy performance of windows with shading devices was modeled using a two step procedure. Solar radiation was considered in the first step by developing a multi-layer solar optical model for glazing/shading systems. This newly developed model is an extension of an existing model for systems of specular glazing layers and includes the effect of layers that create scattered, specifically diffuse, radiation in reflection and/or transmission. Spatially-averaged (effective) optical properties were used to characterise shading layers, including their beam-diffuse split. The multi-layer solar optical model estimates the system solar transmission and absorbed solar components. The absorbed solar components appear as energy source terms in the second step – the heat transfer analysis. The heat transfer analysis involves the formulation of energy balance equations and requires both effective longwave properties and convective heat transfer coefficients as input. The simultaneous solution of the energy balance equations yields the temperature as well as the convective and radiative fluxes. The effective solar optical properties of flat materials like drapery fabrics, roller blinds and insect screens were obtained by developing a new measurement technique. Special sample holders were designed and fabricated to facilitate measurements using an integrating sphere installed in a commercially available spectrophotometer. Semi-empirical models were then developed to quantify the variation of solar optical properties with respect to incidence angle. In turn, effective layer properties of venetian blinds and pleated drapes were modeled using a more fundamental net radiation scheme. The effective longwave properties of flat materials were obtained by taking measurements with an infrared reflectometer using two backing surfaces. The results enabled simple models to be developed relating emittance and longwave transmittance to openness, emittance and longwave transmittance of the structure. In turn, effective longwave properties of venetian blinds and pleated drapes were modeled using a net radiation scheme. Convective heat transfer correlations were readily available. Finally, the newly developed models were validated by measuring the solar gain through various shading devices attached to a double glazed window using the National Solar Test Facility (NSTF) solar simulator and solar calorimeter. Solar gain results were also obtained from simulation software that incorporated the models. There was good agreement between the measured and the simulated results thus strengthening confidence in the newly developed models.
94

Measurements and Models Related to Solar Optics in Windows with Shading Devices

Kotey, Nathan Amon 06 April 2009 (has links)
Shading devices have the potential to reduce peak cooling load and annual energy consumption because they can be used to control solar gain. Thus, the need to model shading devices in a glazing system analysis is important. This thesis deals with various measurement techniques and model development related to solar optics in windows with shading devices. It also considers longwave radiative properties of shading devices via model development and experimentation. The different shading devices examined were roller blinds, insect screens, pleated drapes and venetian blinds. The energy performance of windows with shading devices was modeled using a two step procedure. Solar radiation was considered in the first step by developing a multi-layer solar optical model for glazing/shading systems. This newly developed model is an extension of an existing model for systems of specular glazing layers and includes the effect of layers that create scattered, specifically diffuse, radiation in reflection and/or transmission. Spatially-averaged (effective) optical properties were used to characterise shading layers, including their beam-diffuse split. The multi-layer solar optical model estimates the system solar transmission and absorbed solar components. The absorbed solar components appear as energy source terms in the second step – the heat transfer analysis. The heat transfer analysis involves the formulation of energy balance equations and requires both effective longwave properties and convective heat transfer coefficients as input. The simultaneous solution of the energy balance equations yields the temperature as well as the convective and radiative fluxes. The effective solar optical properties of flat materials like drapery fabrics, roller blinds and insect screens were obtained by developing a new measurement technique. Special sample holders were designed and fabricated to facilitate measurements using an integrating sphere installed in a commercially available spectrophotometer. Semi-empirical models were then developed to quantify the variation of solar optical properties with respect to incidence angle. In turn, effective layer properties of venetian blinds and pleated drapes were modeled using a more fundamental net radiation scheme. The effective longwave properties of flat materials were obtained by taking measurements with an infrared reflectometer using two backing surfaces. The results enabled simple models to be developed relating emittance and longwave transmittance to openness, emittance and longwave transmittance of the structure. In turn, effective longwave properties of venetian blinds and pleated drapes were modeled using a net radiation scheme. Convective heat transfer correlations were readily available. Finally, the newly developed models were validated by measuring the solar gain through various shading devices attached to a double glazed window using the National Solar Test Facility (NSTF) solar simulator and solar calorimeter. Solar gain results were also obtained from simulation software that incorporated the models. There was good agreement between the measured and the simulated results thus strengthening confidence in the newly developed models.
95

Habitatpreferenser hos tjockskalig målarmussla (Unio crassus) med avseende på vattendjup och beskuggning. / Habitat preferences of the thick-shelled river mussel (Unio crassus) regarding water depth and shading.

Lundberg, Malin January 2012 (has links)
The thick-shelled river mussel (Unio crassus) is a red listed species classified as Endangered (EN) and is also considered within the Habitats Directive. The distribution in Sweden is fragmented and it is mostly occurring in the south eastern parts. We investigated the presence of Unio crassus in a section of the stream Storån, Östergötland County, from Falerum to the inflow into Lake Åkervristen. The environmental parameters investigated were water depth, bottom substrate, shading, water velocity and the slope over the water surface. In this thesis I have focused mainly on water depth and shading, comparing sites with and without mussels. In addition, I used a multivariate PCA analysis to evaluate all parameters together. The water depth was significantly larger in habitats with mussels than in those without. Shading varied from 5 to 80 %, but there was no significant difference between habitats with and without mussels. There was no correlation between water depth and mussel density and not between shading and mussel density either. The multivariate PCA analysis showed that the habitats with and without mussels were different from with regard to the PC1 axis, which included water depth, bottom substrate and water velocity. Alone, the water depth is not enough to predict the presence of Unio crassus in the stream, and it is likely that more parameters need to be considered.  Previous work indicate that the more parameters and habitats that are investigated, the more confident results can be stated of which habitats Unio crassus prefer.
96

Study of building solar insolation with 3D GIS¡VAnalysis of shadow shading and solar radiation

Tao, Cheng-keng 07 December 2005 (has links)
Sunshine, air and water are the vital elements to the human. This study investigated the insolation and solar radiation in Kaohsiung city. Solar radiation on the horizontal and declined plane was calculated. Sun shadow model for urban buildings was constructed for computing accumulated sunshining hours. Horizontal and vertical building shadows were displayed in ArcGIS ¡V the GIS software. Raster-based data model was used to analyze the effect of sun shadow shading by neighbour buildings. And the effect of shadow shading for solar water heater was also investigated. According to the results, minor installation error of orientation and decline angles of solar panel will not cause major energy loss. And the distance between the buildings¡Bthe height difference and the orientation between buildings are most important factors which affect optimal installation location of the solar water heater. If there are buildings located to the south, southeast and southwest, and the stories difference between buildings is over three, the installing location should be moved toward north. If buildings are next to each others and the variation of height is large, the efficient of receiving solar radiation will be deteriorated. The larger is the distance between buildings, the better the energy received.
97

The incorporation of bubbles into a computer graphics fluid simulation

Greenwood, Shannon Thomas 29 August 2005 (has links)
We present methods for incorporating bubbles into a photorealistc fluid simulation. Previous methods of fluid simulation in computer graphics do not include bubbles. Our system automatically creates bubbles, which are simulated on top of the fluid simulation. These bubbles are approximated by spheres and are rendered with the fluid to appear as one continuous surface. This enhances the overall realism of the appearance of a splashing fluid for computer graphics. Our methods leverage the particle level set representation of the fluid surface. We create bubbles from escaped marker particles from the outside to the inside. These marker particles might represent air that has been trapped within the fluid surface. Further, we detect when air is trapped in the fluid and create bubbles within this space. This gives the impression that the air pocket has become bubbles and is an inexpensive way to simulate the air trapped in air pockets. The results of the simulation are rendered with a raytracer that includes caustics. This allows the creation of photorealistic images. These images support our position that the simple addition of bubbles included in a fluid simulation creates results that are much more true to life.
98

Deferred Rendering : Jämförelse mellan traditionell deferred rendering och light pre-pass rendering

Bernhardsson, Johan January 1987 (has links)
<p>Då scenkomplexitet och ett högre antal ljuskällor blir vanligare inom spel har ett behov av algortimer för att hantera dessa scener, med bra prestanda, uppståt. En allt vanligare algoritm för detta är Deferred Shading. Rapporten utvärderar två olika metoder för <em>Deferred Shading</em> (traditionell <em>Deferred Shading</em> och <em>Light pre-pass rendering</em>).</p>
99

Feasibility study of an integrated wind and solar farm by evaluating the wind turbine shadows

Shanghavi, Sahil 10 July 2012 (has links)
This thesis analyzes the feasibility of having an integrated wind and solar farm to optimize the use of land resources and capital investment by evaluating the effect that wind turbine shadows have on the area surrounding them. Two methods are used to predict shadow impact. The first method is based on the traditional textbook “Clear Sky” equations, which have maximum sensitivity to shadows because the method considers every day to be a perfect day. The second method uses measured global-horizontal and diffuse-horizontal solar radiation in units of W/m2, which take into account the true variations of daily conditions. The calculations are performed for 1 square meter surfaces, over different assumed areas of a wind power plant, for every second of the day. For purposes of shadow calculations, the tip-top height (i.e., tower height plus blade length) is used. All calculations are performed with the specifications of a GE 1.5 MW wind turbine, which is the most commonly used wind turbine in USA. / text
100

High performance façades for commercial buildings

Bader, Stefan 30 November 2010 (has links)
Due to the fact that construction, maintenance and operation of buildings consume almost 50% of the energy today, architects play a major role in the reduction of energy consumption. The building’s envelope (façades and roof) can have a significant and measurable impact. With regard to overheating and the potential lost of internal heat, transparent parts of the building envelope have a large effect on the building’s energy consumption. Modern, transparent façade systems can fulfill contemporary demands, such as energy conservation, energy production or the degree of visual contact, of sustainable buildings in order to reduce internal heating, cooling, and electrical loads. An analysis of existing shading devices and façade design leads to a comparative analysis of conventional shading devices like horizontal and vertical blinds as well as eggcrate and honeycomb shading structures in a hot-humid climate like Austin, Texas. This study helped evaluating strengths and weaknesses of each device resulting in an optimization process of conventional shading devices. Ultimately, an optimized shading structure has been developed. This project aimed to develop an advanced transparent façade system for a south-oriented commercial façade in Austin, Texas, which fulfills high standards with regard to low energy use, by limiting cooling loads and demands for artificial lighting while avoiding glare and heat losses during the cold season. The optimization has been achieved in providing full shading for a specified period of time throughout the year while providing maximized solar exposure. The shading structure consists out of an array of fixed shading components varying in size and proportion to fulfill criteria like specific views, transparency and aesthetics. The shading structure has been compared to conventional shading devices and analyzed with regard to the reduction of annual solar radiation. The improvement in design and energy consumption contributes to the variety of shading structures for building skins. It is anticipated that the solutions will help to widen the options for aesthetically pleasing, high-performance façades for commercial buildings. / text

Page generated in 0.0367 seconds