• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 18
  • 18
  • 18
  • 12
  • 7
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desenvolvimento e avaliação de novas abordagens de modelagem de processos de separação em leito móvel simulado / Development and evaluation of new approaches to modeling of the separations process in simulated moving bed

Anderson Luis Jeske Bihain 10 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O Leito Móvel Simulado (LMS) é um processo de separação de compostos por adsorção muito eficiente, por trabalhar em um regime contínuo e também possuir fluxo contracorrente da fase sólida. Dentre as diversas aplicações, este processo tem se destacado na resolução de petroquímicos e principalmente na atualidade na separação de misturas racêmicas que são separações de um grau elevado de dificuldade. Neste trabalho foram propostas duas novas abordagens na modelagem do LMS, a abordagem Stepwise e a abordagem Front Velocity. Na modelagem Stepwise as colunas cromatográficas do LMS foram modeladas com uma abordagem discreta, onde cada uma delas teve seu domínio dividido em N células de mistura interligadas em série, e as concentrações dos compostos nas fases líquida e sólida foram simuladas usando duas cinéticas de transferência de massa distintas. Essa abordagem pressupõe que as interações decorrentes da transferência de massa entre as moléculas do composto nas suas fases líquida e sólida ocorram somente na superfície, de forma que com essa suposição pode-se admitir que o volume ocupado por cada molécula nas fases sólida e líquida é o mesmo, o que implica que o fator de residência pode ser considerado igual a constante de equilíbrio. Para descrever a transferência de massa que ocorre no processo cromatográfico a abordagem Front Velocity estabelece que a convecção é a fase dominante no transporte de soluto ao longo da coluna cromatográfica. O Front Velocity é um modelo discreto (etapas) em que a vazão determina o avanço da fase líquida ao longo da coluna. As etapas são: avanço da fase líquida e posterior transporte de massa entre as fases líquida e sólida, este último no mesmo intervalo de tempo. Desta forma, o fluxo volumétrico experimental é utilizado para a discretização dos volumes de controle que se deslocam ao longo da coluna porosa com a mesma velocidade da fase líquida. A transferência de massa foi representada por dois mecanismos cinéticos distintos, sem (tipo linear) e com capacidade máxima de adsorção (tipo Langmuir). Ambas as abordagens propostas foram estudadas e avaliadas mediante a comparação com dados experimentais de separação em LMS do anestésico cetamina e, posteriormente, com o fármaco Verapamil. Também foram comparados com as simulações do modelo de equilíbrio dispersivo para o caso da Cetamina, usado por Santos (2004), e para o caso do Verapamil (Perna 2013). Na etapa de caracterização da coluna cromatográfica as novas abordagens foram associadas à ferramenta inversa R2W de forma a determinar os parâmetros globais de transferência de massa apenas usando os tempos experimentais de residência de cada enantiômero na coluna de cromatografia líquida de alta eficiência (CLAE). Na segunda etapa os modelos cinéticos desenvolvidos nas abordagens foram aplicados nas colunas do LMS com os valores determinados na caracterização da coluna cromatográfica, para a simulação do processo de separação contínua. Os resultados das simulações mostram boa concordância entre as duas abordagens propostas e os experimentos de pulso para a caracterização da coluna na separação enantiomérica da cetamina ao longo do tempo. As simulações da separação em LMS, tanto do Verapamil quando da Cetamina apresentam uma discrepância com os dados experimentais nos primeiros ciclos, entretanto após esses ciclos iniciais a correlação entre os dados experimentais e as simulações. Para o caso da separação da cetamina (Santos, 2004), a qual a concentração da alimentação era relativamente baixa, os modelos foram capazes de predizer o processo de separação com as cinéticas Linear e Langmuir. No caso da separação do Verapamil (Perna, 2013), onde a concentração da alimentação é relativamente alta, somente a cinética de Langmuir representou o processo, devido a cinética Linear não representar a saturação das colunas cromatográficas. De acordo como o estudo conduzido ambas as abordagens propostas mostraram-se ferramentas com potencial na predição do comportamento cromatográfico de uma amostra em um experimento de pulso, assim como na simulação da separação de um composto no LMS, apesar das pequenas discrepâncias apresentadas nos primeiros ciclos de trabalho do LMS. Além disso, podem ser facilmente implementadas e aplicadas na análise do processo, pois requer um baixo número de parâmetros e são constituídas de equações diferenciais ordinárias. / Simulated Moving Bed (SMB) is a very efficient process in the compounds separation by adsorption, because works in a continuous regime, and with countercurrent flow of the solid phase. Among different applications, SMB has stood out in the petrochemical products separation and mainly in the separation of racemic compounds, which are separations of a high degree of difficulty. In this work, two new approaches to modeling the LMS process have been proposed, stepwise approach and Front Velocity approach. In the Stepwise approach, each chromatographic column of the SMB, is divided in to N cells connected in series, and the concentrations of compounds in liquid and solid phases were simulated using two different kinetics of mass transfer. This approach assumes that the interactions resulting from the mass transfer between the molecules of the compound in its liquid and solid phases occur only on the surface. So that with this assumption the volume occupied by each molecule in the solid and liquid phases is the same, implying that the factor of residence is equal to the equilibrium constant. To describe the mass transfer that occurs in the Chromatographic process, the Front Velocity approach considers that the convection is the dominant phase in the solute transport along the chromatographic column. The "Front Velocity" is a discrete model (steps) where the flow rate determines the liquid phase advance along the column. The steps are: advancing liquid phase and subsequent mass transfer between the liquid and solid phases, the latter in the same time interval. Thus, the experimental volumetric flow is used for the discretization of the control volume moving along the porous column with the same velocity of the liquid phase. The mass transfer was represented by two distinct kinetic mechanisms without (linear type) and with maximum adsorption capacity (Langmuir type). Both proposed approaches were studied and evaluated by comparison with experimental data separation LMS of the anesthetic ketamine and subsequently with the drug Verapamil. Were also compared with the simulations of dispersive equilibrium model for the case of ketamine used by Santos (2004) and the simulations of the software Help for the case of Verapamil (Perna 2013). In the chromatographic column characterization step, the new approaches have been associated with inverse R2W tool to determine the global mass transfer parameters using only the experimental residence times of each enantiomer in the high performance liquid chromatography (HPLC) column. In the second step, the kinetic models developed in both approaches were applied to the columns of the LMS with the values determined in the characterization of the chromatographic column step, for the simulation of continuous separation process. The simulation results show good agreement between the two proposed approaches and pulse experiments to characterize the column in the enantiomeric separation of ketamine over time. In the simulation of the SMB process, when the approaches admit one kinetic mechanism of the Langmuir type showed good agreement with the results obtained from the dispersive equilibrium model, it is a classical tool for the simulation of this process. While using a kinetic linear mechanism the results is more similar to the experimental data. According to the study conducted, both the proposed approaches were shown to be potential tools to predict the chromatographic behavior of a sample in a test pulse, as well as the simulation of separation of a compound in SMB process despite minor discrepancies presented in the first work cycles of the SMB. Moreover, the approaches can be easily programed and applied in the analysis of the process, because it requires a low number of parameters and consist of ordinary differential equations.
12

Desenvolvimento e avaliação de novas abordagens de modelagem de processos de separação em leito móvel simulado / Development and evaluation of new approaches to modeling of the separations process in simulated moving bed

Anderson Luis Jeske Bihain 10 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O Leito Móvel Simulado (LMS) é um processo de separação de compostos por adsorção muito eficiente, por trabalhar em um regime contínuo e também possuir fluxo contracorrente da fase sólida. Dentre as diversas aplicações, este processo tem se destacado na resolução de petroquímicos e principalmente na atualidade na separação de misturas racêmicas que são separações de um grau elevado de dificuldade. Neste trabalho foram propostas duas novas abordagens na modelagem do LMS, a abordagem Stepwise e a abordagem Front Velocity. Na modelagem Stepwise as colunas cromatográficas do LMS foram modeladas com uma abordagem discreta, onde cada uma delas teve seu domínio dividido em N células de mistura interligadas em série, e as concentrações dos compostos nas fases líquida e sólida foram simuladas usando duas cinéticas de transferência de massa distintas. Essa abordagem pressupõe que as interações decorrentes da transferência de massa entre as moléculas do composto nas suas fases líquida e sólida ocorram somente na superfície, de forma que com essa suposição pode-se admitir que o volume ocupado por cada molécula nas fases sólida e líquida é o mesmo, o que implica que o fator de residência pode ser considerado igual a constante de equilíbrio. Para descrever a transferência de massa que ocorre no processo cromatográfico a abordagem Front Velocity estabelece que a convecção é a fase dominante no transporte de soluto ao longo da coluna cromatográfica. O Front Velocity é um modelo discreto (etapas) em que a vazão determina o avanço da fase líquida ao longo da coluna. As etapas são: avanço da fase líquida e posterior transporte de massa entre as fases líquida e sólida, este último no mesmo intervalo de tempo. Desta forma, o fluxo volumétrico experimental é utilizado para a discretização dos volumes de controle que se deslocam ao longo da coluna porosa com a mesma velocidade da fase líquida. A transferência de massa foi representada por dois mecanismos cinéticos distintos, sem (tipo linear) e com capacidade máxima de adsorção (tipo Langmuir). Ambas as abordagens propostas foram estudadas e avaliadas mediante a comparação com dados experimentais de separação em LMS do anestésico cetamina e, posteriormente, com o fármaco Verapamil. Também foram comparados com as simulações do modelo de equilíbrio dispersivo para o caso da Cetamina, usado por Santos (2004), e para o caso do Verapamil (Perna 2013). Na etapa de caracterização da coluna cromatográfica as novas abordagens foram associadas à ferramenta inversa R2W de forma a determinar os parâmetros globais de transferência de massa apenas usando os tempos experimentais de residência de cada enantiômero na coluna de cromatografia líquida de alta eficiência (CLAE). Na segunda etapa os modelos cinéticos desenvolvidos nas abordagens foram aplicados nas colunas do LMS com os valores determinados na caracterização da coluna cromatográfica, para a simulação do processo de separação contínua. Os resultados das simulações mostram boa concordância entre as duas abordagens propostas e os experimentos de pulso para a caracterização da coluna na separação enantiomérica da cetamina ao longo do tempo. As simulações da separação em LMS, tanto do Verapamil quando da Cetamina apresentam uma discrepância com os dados experimentais nos primeiros ciclos, entretanto após esses ciclos iniciais a correlação entre os dados experimentais e as simulações. Para o caso da separação da cetamina (Santos, 2004), a qual a concentração da alimentação era relativamente baixa, os modelos foram capazes de predizer o processo de separação com as cinéticas Linear e Langmuir. No caso da separação do Verapamil (Perna, 2013), onde a concentração da alimentação é relativamente alta, somente a cinética de Langmuir representou o processo, devido a cinética Linear não representar a saturação das colunas cromatográficas. De acordo como o estudo conduzido ambas as abordagens propostas mostraram-se ferramentas com potencial na predição do comportamento cromatográfico de uma amostra em um experimento de pulso, assim como na simulação da separação de um composto no LMS, apesar das pequenas discrepâncias apresentadas nos primeiros ciclos de trabalho do LMS. Além disso, podem ser facilmente implementadas e aplicadas na análise do processo, pois requer um baixo número de parâmetros e são constituídas de equações diferenciais ordinárias. / Simulated Moving Bed (SMB) is a very efficient process in the compounds separation by adsorption, because works in a continuous regime, and with countercurrent flow of the solid phase. Among different applications, SMB has stood out in the petrochemical products separation and mainly in the separation of racemic compounds, which are separations of a high degree of difficulty. In this work, two new approaches to modeling the LMS process have been proposed, stepwise approach and Front Velocity approach. In the Stepwise approach, each chromatographic column of the SMB, is divided in to N cells connected in series, and the concentrations of compounds in liquid and solid phases were simulated using two different kinetics of mass transfer. This approach assumes that the interactions resulting from the mass transfer between the molecules of the compound in its liquid and solid phases occur only on the surface. So that with this assumption the volume occupied by each molecule in the solid and liquid phases is the same, implying that the factor of residence is equal to the equilibrium constant. To describe the mass transfer that occurs in the Chromatographic process, the Front Velocity approach considers that the convection is the dominant phase in the solute transport along the chromatographic column. The "Front Velocity" is a discrete model (steps) where the flow rate determines the liquid phase advance along the column. The steps are: advancing liquid phase and subsequent mass transfer between the liquid and solid phases, the latter in the same time interval. Thus, the experimental volumetric flow is used for the discretization of the control volume moving along the porous column with the same velocity of the liquid phase. The mass transfer was represented by two distinct kinetic mechanisms without (linear type) and with maximum adsorption capacity (Langmuir type). Both proposed approaches were studied and evaluated by comparison with experimental data separation LMS of the anesthetic ketamine and subsequently with the drug Verapamil. Were also compared with the simulations of dispersive equilibrium model for the case of ketamine used by Santos (2004) and the simulations of the software Help for the case of Verapamil (Perna 2013). In the chromatographic column characterization step, the new approaches have been associated with inverse R2W tool to determine the global mass transfer parameters using only the experimental residence times of each enantiomer in the high performance liquid chromatography (HPLC) column. In the second step, the kinetic models developed in both approaches were applied to the columns of the LMS with the values determined in the characterization of the chromatographic column step, for the simulation of continuous separation process. The simulation results show good agreement between the two proposed approaches and pulse experiments to characterize the column in the enantiomeric separation of ketamine over time. In the simulation of the SMB process, when the approaches admit one kinetic mechanism of the Langmuir type showed good agreement with the results obtained from the dispersive equilibrium model, it is a classical tool for the simulation of this process. While using a kinetic linear mechanism the results is more similar to the experimental data. According to the study conducted, both the proposed approaches were shown to be potential tools to predict the chromatographic behavior of a sample in a test pulse, as well as the simulation of separation of a compound in SMB process despite minor discrepancies presented in the first work cycles of the SMB. Moreover, the approaches can be easily programed and applied in the analysis of the process, because it requires a low number of parameters and consist of ordinary differential equations.
13

The Design of Continuous Chromatography for Separation and Purification

David M Harvey (8782685) 30 April 2020 (has links)
Continuous chromatography is an attractive alternative to traditional batch chromatography because it can have higher productivity, solvent efficiency, and product concentrations. However, several barriers prevent further use of continuous chromatography. There are many operating parameters that must be determined when designing continuous systems making it difficult to achieve high purity, yield, and productivity. Through the identification and strategic combination of the key dimensionless groups that control a continuous separation, it is possible to design highly productive systems that produce products with high yield and high purity. In this dissertation, three examples were selected to demonstrate the significance of a model-based method when designing continuous chromatography systems. (1) The Speedy Standing Wave Design and simulated moving bed splitting strategies for the separation of ternary mixtures with linear isotherms. (2) The Standing-wave Design of Three-Zone open-loop non-isocratic SMB for purification. (3) The Continuous Ligand-Assisted Displacement for the separation of Rare Earth Elements.<div>In the first example, the Speedy Standing Wave Design equations were developed for multicomponent separations with linear isotherms and a systematic splitting strategy was developed for the design of multiple sequential Simulated Moving Beds (SMBs). By performing the easiest split first, the overall productivity and solvent efficiency can be significantly improved. Rate model simulations were used to verify that the SSWD equations achieved target yields and purities. In systems where only one component is desired, the sorbent should be selected such that this component is the most or least retained so that it can be separated in a single SMB.</div><div>In the second example, the Standing Wave Design method was extended to non-isocratic three zone open loop SMBs. The standing wave design equations were derived and then verified using rate model simulations. In two case studies it was shown that non-isocratic SMBs designed using the standing wave design method show an order of magnitude higher productivity than a comparable batch system when the impurities are weakly adsorbing. When the impurities are competitive, the SWD method produces SMB systems with 2 orders of magnitude higher productivity than comparable batch systems. Because the design is based on dimensionless groups, the resulting designs are easily scalable and no rate model simulations are required to design high yield, high purity, and high productivity SMBs.</div><div>In the third example, the constant pattern design method was extended to continuous LAD systems. A continuous operation mode was developed that reduced the cycle time of LAD systems to further increase the productivity. In cases where the feed was equimolar, the continuous configuration increased the productivity between 20-50%. A multizone continuous LAD configuration was developed for the separation of a complex mixture of Dy, ND, and Pr that simulated a crude magnet feed. The resulting overall productivity for this system was 190 kg/m<sup>3</sup>day which was two orders of magnitude higher than a single column batch system and 70% higher than a multizone batch system. The robustness of the constant pattern design method was demonstrated through a simulated case study and it was determined that adding a safety factor through the reduction of the flowrate was more effective than reducing the design length.</div><div>Using a model-based design allows for the consistent design of continuous chromatography systems. The effects of a change in a feed or operating condition can be more easily understood through the lens of the model. This means that adjustments can be made pre-emptively when necessary and the new designs can be tested with virtual experiments before being implemented. The understanding of key dimensionless groups allows for designs that meet key design criteria at all scales of operation and thus allows for the easy transition from one scale to another.</div>
14

Extension du concept "One-column" au lit mobile simulé réactif : application à la séparation réactive des C8 aromatiques / Extension of the "One-column" concept to reactive simulated moving bed processes : application to C8 aromatics reactive separation

Bergeot, Ghislain 04 November 2010 (has links)
La séparation des C8 aromatiques par Lit Mobile Simulé (LMS) permet d'obtenir du paraxylène (PX) pur. Les autres composés du mélange sont recyclés dans un réacteur afin d'être isomérisés puis séparés à nouveau. La charge du LMS est composée à environ 75% par ce flux de recyclage. L'intégration de la réaction dans le LMS, réalisée en intercalant des réacteurs d'isomérisation entre les lits d'adsorbant de la zone 3 (procédé LMS Réactif, LMSR), doit permettre une réduction de ce flux de recyclage.L'objectif de cette thèse est de développer une méthodologie d'étude des procédés de type Lit Mobile Simulé (LMS) et Lit Mobile Simulé Réactif (LMSR) basée sur :-un outil expérimental simplifié : le pilote One-column réactif (OCR)-des simulateurs One-column réactif ou non qui seront validés par les résultats expérimentaux du pilote-des simulateurs LMS et LMSR permettant d'accéder aux résultats des procédés industriels.Les simulations de One-column (OC) montrent une bonne sensibilité aux paramètres clés de la séparation des C8 aromatiques (sélectivité PX/EB et diffusion intracristalline). Les résultats expérimentaux font ressortir des difficultés importantes à mettre en œuvre le OC expérimentalement. Plusieurs hypothèses sont exposées pour expliquer les résultats obtenus mais les difficultés rencontrées limitent, en l'état, l'utilisation du pilote pour l'étude de la séparation (réactive ou non) des C8 aromatiques.L'étude du LMSR effectuée par simulation montre l'importance du nombre et de l'emplacement des réacteurs ainsi que de l'intégration du LMSR dans la boucle de production de PX. L'usage du LMSR pour la production de PX permet une réduction importante du débit de recyclage / Today, pure paraxylene (PX) is mainly obtained from a mix of C8 aromatics by a separation process based on adsorption: the Simulated Moving Bed (SMB). The other components of the blend are sent to an isomerisation reactor and are recycled to the SMB. 75% of the SMB feed flow rate come from this recycle flow. Coupling reaction and separation by inserting isomerisation reactors between the adsorption beds of the third zone (Simulated Moving Bed Reactor, SMBR) should allow a reduction of this recycling flow rate.The main objective of this thesis is to develop a new methodology for studying SMB and SMBR processes based on:- a simplify experimental tool : the One-column reactive (OCR) pilot unit- simulators of the OCR which will be validated by the experimental results obtain on the pilot unit- simulators of SMB and SMBR processes which give access to industrial processes results.Simulation results show that OC system seem to be sensitive to key parameters of C8 aromatics separation (PX/EB selectivity and micropore diffusivity). Results on the pilot unit highlight the difficulties to implement an experimental OC. Hypothesis are given to explain those results but, without modification, OCR pilot unit cannot be used to study xylene separation (with or without reaction).SMBR study done by simulation shows the impact of the placement and the number of reactors. Integration of SMBR in the global PX production scheme is also essential. SMBR allows an important reduction of recycling flow rate (up to 50%).
15

Cromatografia continua em leito movel simulado para a purificação dos enantiomeros do N-Boc-baclofeno-lactama / Continous chromatographic in simulated moving bed to purification of enantiomers N-Boc-baclofen-lactan

Veredas, Vinícius de 18 April 2005 (has links)
Orientador: Cesar Costapinto Santana / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-09-05T13:20:08Z (GMT). No. of bitstreams: 1 Veredas_ViniciusDe_D.pdf: 13205142 bytes, checksum: 97c5009c255088bef6fcdc1fd92294c3 (MD5) Previous issue date: 2005 / Doutorado / Desenvolvimento de Processos Biotecnologicos / Mestre em Engenharia Química
16

Cromatografia continua em leito movel simulado para a purificação dos enantiomeros do N-Boc-baclofeno-lactama / Continous chromatographic in simulated moving bed to purification of enantiomers N-Boc-baclofen-lactan

Veredas, Vinícius de 18 April 2005 (has links)
Orientador: Cesar Costapinto Santana / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-30T12:54:54Z (GMT). No. of bitstreams: 1 Veredas, Vinicius de_D.pdf: 13205142 bytes, checksum: 97c5009c255088bef6fcdc1fd92294c3 (MD5) Previous issue date: 2005 / Doutorado / Desenvolvimento de Processos Biotecnologicos / Mestre em Engenharia Química
17

Problemas direto e inverso de processos de separação em leito móvel simulado mediante mecanismos cinéticos de adsorção / Direct and inverse problems of separation processes moving bed simulated by kinetic mechanisms of adsorption

Kamilla Vogas Romualdo 21 December 2012 (has links)
Diversas aplicações industriais relevantes envolvem os processos de adsorção, citando como exemplos a purificação de produtos, separação de substâncias, controle de poluição e umidade entre outros. O interesse crescente pelos processos de purificação de biomoléculas deve-se principalmente ao desenvolvimento da biotecnologia e à demanda das indústrias farmacêutica e química por produtos com alto grau de pureza. O leito móvel simulado (LMS) é um processo cromatográfico contínuo que tem sido aplicado para simular o movimento do leito de adsorvente, de forma contracorrente ao movimento do líquido, através da troca periódica das posições das correntes de entrada e saída, sendo operado de forma contínua, sem prejuízo da pureza das correntes de saída. Esta consiste no extrato, rico no componente mais fortemente adsorvido, e no rafinado, rico no componente mais fracamente adsorvido, sendo o processo particularmente adequado a separações binárias. O objetivo desta tese é estudar e avaliar diferentes abordagens utilizando métodos estocásticos de otimização para o problema inverso dos fenômenos envolvidos no processo de separação em LMS. Foram utilizados modelos discretos com diferentes abordagens de transferência de massa, com a vantagem da utilização de um grande número de pratos teóricos em uma coluna de comprimento moderado, neste processo a separação cresce à medida que os solutos fluem através do leito, isto é, ao maior número de vezes que as moléculas interagem entre a fase móvel e a fase estacionária alcançando assim o equilíbrio. A modelagem e a simulação verificadas nestas abordagens permitiram a avaliação e a identificação das principais características de uma unidade de separação do LMS. A aplicação em estudo refere-se à simulação de processos de separação do Baclofen e da Cetamina. Estes compostos foram escolhidos por estarem bem caracterizados na literatura, estando disponíveis em estudos de cinética e de equilíbrio de adsorção nos resultados experimentais. De posse de resultados experimentais avaliou-se o comportamento do problema direto e inverso de uma unidade de separação LMS visando comparar os resultados obtidos com os experimentais, sempre se baseando em critérios de eficiência de separação entre as fases móvel e estacionária. Os métodos estudados foram o GA (Genetic Algorithm) e o PCA (Particle Collision Algorithm) e também foi feita uma hibridização entre o GA e o PCA. Como resultado desta tese analisouse e comparou-se os métodos de otimização em diferentes aspectos relacionados com o mecanismo cinético de transferência de massa por adsorção e dessorção entre as fases sólidas do adsorvente. / Several important industrial applications involving adsorption processes, citing as an example the product purification, separation of substances, pollution control and moisture among others. The growing interest in processes of purification of biomolecules is mainly due to the development of biotechnology and the demand of pharmaceutical and chemical products with high purity. The simulated moving bed (SMB) chromatography is a continuous process that has been applied to simulate the movement of the adsorbent bed, in a countercurrent to the movement of liquid through the periodic exchange of the positions of input and output currents, being operated so continuous, notwithstanding the purity of the outlet streams. This is the extract, rich in the more strongly adsorbed component, and the raffinate, rich in the more weakly adsorbed component, the method being particularly suited to binary separations. The aim of this thesis is to study and evaluate different approaches using stochastic optimization methods for the inverse problem of the phenomena involved in the separation process in LMS. We used discrete models with different approaches to mass transfer. With the benefit of using a large number of theoretical plates in a column of moderate length, in this process the separation increases as the solute flowing through the bed, i.e. as many times as molecules interact between the mobile phase and stationary phase thus achieving the equilibrium. The modeling and simulation verified in these approaches allowed the assessment and identification of the main characteristics of a separation unit LMS. The application under consideration refers to the simulation of the separation of Ketamine and Baclofen. These compounds were chosen because they are well characterized in the literature and are available in kinetic studies and equilibrium adsorption on experimental results. With the results of experiments evaluated the behavior of the direct and inverse problem of a separation unit LMS in order to compare these results, always based on the criteria of separation efficiency between the mobile and stationary phases. The methods studied were the GA (Genetic Algorithm) and PCA (Particle Collision Algorithm) and we also made a hybridization between the GA and PCA. This thesis, we analyzed and compared the optimization methods in different aspects of the kinetic mechanism for mass transfer between the adsorption and desorption of the adsorbent solid phases.
18

Problemas direto e inverso de processos de separação em leito móvel simulado mediante mecanismos cinéticos de adsorção / Direct and inverse problems of separation processes moving bed simulated by kinetic mechanisms of adsorption

Kamilla Vogas Romualdo 21 December 2012 (has links)
Diversas aplicações industriais relevantes envolvem os processos de adsorção, citando como exemplos a purificação de produtos, separação de substâncias, controle de poluição e umidade entre outros. O interesse crescente pelos processos de purificação de biomoléculas deve-se principalmente ao desenvolvimento da biotecnologia e à demanda das indústrias farmacêutica e química por produtos com alto grau de pureza. O leito móvel simulado (LMS) é um processo cromatográfico contínuo que tem sido aplicado para simular o movimento do leito de adsorvente, de forma contracorrente ao movimento do líquido, através da troca periódica das posições das correntes de entrada e saída, sendo operado de forma contínua, sem prejuízo da pureza das correntes de saída. Esta consiste no extrato, rico no componente mais fortemente adsorvido, e no rafinado, rico no componente mais fracamente adsorvido, sendo o processo particularmente adequado a separações binárias. O objetivo desta tese é estudar e avaliar diferentes abordagens utilizando métodos estocásticos de otimização para o problema inverso dos fenômenos envolvidos no processo de separação em LMS. Foram utilizados modelos discretos com diferentes abordagens de transferência de massa, com a vantagem da utilização de um grande número de pratos teóricos em uma coluna de comprimento moderado, neste processo a separação cresce à medida que os solutos fluem através do leito, isto é, ao maior número de vezes que as moléculas interagem entre a fase móvel e a fase estacionária alcançando assim o equilíbrio. A modelagem e a simulação verificadas nestas abordagens permitiram a avaliação e a identificação das principais características de uma unidade de separação do LMS. A aplicação em estudo refere-se à simulação de processos de separação do Baclofen e da Cetamina. Estes compostos foram escolhidos por estarem bem caracterizados na literatura, estando disponíveis em estudos de cinética e de equilíbrio de adsorção nos resultados experimentais. De posse de resultados experimentais avaliou-se o comportamento do problema direto e inverso de uma unidade de separação LMS visando comparar os resultados obtidos com os experimentais, sempre se baseando em critérios de eficiência de separação entre as fases móvel e estacionária. Os métodos estudados foram o GA (Genetic Algorithm) e o PCA (Particle Collision Algorithm) e também foi feita uma hibridização entre o GA e o PCA. Como resultado desta tese analisouse e comparou-se os métodos de otimização em diferentes aspectos relacionados com o mecanismo cinético de transferência de massa por adsorção e dessorção entre as fases sólidas do adsorvente. / Several important industrial applications involving adsorption processes, citing as an example the product purification, separation of substances, pollution control and moisture among others. The growing interest in processes of purification of biomolecules is mainly due to the development of biotechnology and the demand of pharmaceutical and chemical products with high purity. The simulated moving bed (SMB) chromatography is a continuous process that has been applied to simulate the movement of the adsorbent bed, in a countercurrent to the movement of liquid through the periodic exchange of the positions of input and output currents, being operated so continuous, notwithstanding the purity of the outlet streams. This is the extract, rich in the more strongly adsorbed component, and the raffinate, rich in the more weakly adsorbed component, the method being particularly suited to binary separations. The aim of this thesis is to study and evaluate different approaches using stochastic optimization methods for the inverse problem of the phenomena involved in the separation process in LMS. We used discrete models with different approaches to mass transfer. With the benefit of using a large number of theoretical plates in a column of moderate length, in this process the separation increases as the solute flowing through the bed, i.e. as many times as molecules interact between the mobile phase and stationary phase thus achieving the equilibrium. The modeling and simulation verified in these approaches allowed the assessment and identification of the main characteristics of a separation unit LMS. The application under consideration refers to the simulation of the separation of Ketamine and Baclofen. These compounds were chosen because they are well characterized in the literature and are available in kinetic studies and equilibrium adsorption on experimental results. With the results of experiments evaluated the behavior of the direct and inverse problem of a separation unit LMS in order to compare these results, always based on the criteria of separation efficiency between the mobile and stationary phases. The methods studied were the GA (Genetic Algorithm) and PCA (Particle Collision Algorithm) and we also made a hybridization between the GA and PCA. This thesis, we analyzed and compared the optimization methods in different aspects of the kinetic mechanism for mass transfer between the adsorption and desorption of the adsorbent solid phases.

Page generated in 0.0848 seconds