• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 1
  • Tagged with
  • 25
  • 25
  • 19
  • 17
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

INFLUÊNCIA DO LASER DE DIODO NA EVAPORAÇÃO DO SOLVENTE DE SISTEMAS ADESIVOS EM DENTINA. / THE INFLUENCE OF DIODE LASER IN EVAPORATION OF ADHESIVE SYSTEMS SOLVENT IN DENTIN

Chiattone, Tatiana Dalla Costa 29 June 2015 (has links)
This study aimed to evaluate, in vitro, the influence of Diode Laser on the evaporation of adhesive systems solvent applied on the dentin. The groups were distributed in relation to the adhesive systems (Adper Single Bond 2, Adper Scotchbond Multi Purpose, Single Bond Universal, Clearfil SE Bond e Optibond All-in-one) and also to the technique for the evaporation of the solvent (air dry stream or Diode Laser). The degree of evaporation (GE) was determined through the measuring of mass loss through the gravimetric method in an analytical digital balance. To do so, a hundred human third molars had cavities class I made of following a pattern with the diamond burs # 4054 (KG Soresen, Barueri, SP, Brasil), under refrigeration, on which 10 μL were dispensed of each adhesive system, then one of the both techniques of solvent evaporation was applied: air dry stream, from a distance of 10 cm for each 5 seconds (control technique) or Diode Laser irradiated in a continuous mode perpendicularly and from a distance of 1 cm, in the power of 3 W in the interval of 30 seconds (experimental technique). To each one of the adhesive systems and to each one of the evaporation techniques ten monitoring repetitions were realized (n=10). Regarding the experimental technique, the measurements were realized from 5 to 5 seconds, up to 30 seconds. The variation between the initial mass (mi) and the final mass (mf) of the samples, respectively, before and after the application methods of evaporation proposed were turned into GE, by using the following equation: (mi-mf/mi)x100. In this way, to each time interval (5, 10, 15, 20, 25 and 30 seconds) it happened a calculated GE outcome. Those values were submitted to variance analysis (ANOVA) of two factors and Tukey s test as well. To the comparison between both of the evaporation techniques in each adhesive system a t-student test (α=5%) was realized. Basing on the obtained values of the GE, verified on the current study, it is possible to conclude that the irradiation with Diode Laser was capable of inducing the solvent evaporation of the tested adhesive systems, being superior to the control technique when used in the time of 30 seconds, excepted to the Optibond-all-in-one adhesive system. / Este estudo objetivou avaliar, in vitro, a influência do Laser de Diodo sobre a evaporação do solvente de sistemas adesivos aplicados sobre dentina. Os grupos foram distribuídos em função dos sistemas adesivos (Adper Single Bond 2, Adper Scotchbond Multi Purpose, Single Bond Universal, Clearfil SE Bond e Optibond All-in-one) e da técnica para a evaporação do solvente (jato de ar ou Laser de Diodo). O grau de evaporação (GE) foi determinado através da mensuração da perda de massa pelo método gravimétrico. Para tal, 100 terceiros molares humanos tiveram cavidades classe I confeccionadas de forma padronizada com ponta diamantada em alta rotação (# 4054, KG Soresen, Barueri, SP, Brasil), sob refrigeração, nas quais foi dispensado 10 μL de cada sistema adesivo, seguido da aplicação de uma das técnicas de evaporação do solvente: jato de ar a uma distância de 10 cm por 5 segundos (técnica controle) ou Laser de Diodo irradiado em modo contínuo, perpendicularmente e a uma distância de 1 cm, na potência de 3W no tempo de 30 segundos (técnica experimental). Para cada um dos sistemas adesivos e para cada uma das técnicas de evaporação foram realizadas dez repetições de monitoramento (n=10). Para a técnica experimental as mensurações foram realizadas de 5 em 5 segundos, até 30 segundos. A variação entre massa inicial (mi) e final (mf) das amostras, respectivamente, antes e após a aplicação dos protocolos de evaporação propostos, foram transformadas em GE aplicando-se a seguinte equação: (mi-mf/mi)x100. Portanto, para cada intervalo de tempo, 5, 10, 15, 20, 25 e 30 segundos, houve um desfecho GE calculado. Os resultados foram submetidos à análise de variância (ANOVA) de dois fatores e teste de Tukey. Para comparação entre as técnicas de evaporação em cada sistema adesivo foi utilizado teste t-student (α = 5%).Com base nos valores obtidos do GE verificados no presente estudo, o laser provocou maior evaporação do solvente quando comparado ao Jato de ar, no tempo de 30 segundos, exceto para o sistema adesivo acetonado. Desta forma, a irradiação com Laser de Diodo foi capaz de provocar a evaporação do solvente dos sistemas adesivos testados, sendo superior à técnica controle quando utilizada no tempo de 30 segundos, exceto para o sistema adesivo Optibond-all-in-one.
12

Influência de diferentes sistemas adesivos dentários resinosos aplicados em dentina humana frente a um desafio cariogênico bacteriano, in vitro / The influence of different resin dental adhesive systems applied to human dentine in the face of an in vitro bacterial cariogenic challenge, in vitro

Espejo, Luciana Cardoso 21 October 2008 (has links)
Neste estudo, o objetivo foi avaliar, in vitro, o comportamento de três sistemas adesivos dentários (SAD), sendo dois autocondicionantes Clearfil SE Bond Kuraray Co (CSEB) e Xeno III Dentsply (X-III) e um condicione e lave de 3 passos Scothbond Multi-Purpose Plus - 3M ESPE (SBMP), no que se refere à inibição de lesões recidivantes de cárie em dentina, frente à um desafio cariogênico bacteriano, que utilizou uma cepa de Streptococcus mutans. Além destes materiais, foi inserido no estudo um controle negativo (CN), o qual não recebeu tratamento adesivo. A amostra formada por terceiros molares humanos (n=40) foi preparada com cavidades Classe V e restaurada com a resina composta (RC) Z250 (3M ESPE), deixando-se um nicho na interface restauração/dente na parede gengival em dentina. Os quatro grupos experimentais (n=10) foram submetidos ao desafio cariogênico para o desenvolvimento das lesões durante 30 dias. Foi realizada em microscopia óptica de luz (MOL) a medição das variáveis: profundidade da lesão de parede, extensão da lesão de parede e profundidade da lesão externa e em MEV (Microscopia Eletrônica de Varredura) a análise morfológica das lesões de cárie formadas. Os dados referentes às lesões foram analisados através de Análise de Variância, testes auxiliares, além do Teste de Brown e Forsythe, com grau de significância de 5%. A metodologia adotada foi capaz de desenvolver lesões externas e de parede e de padronizar uma fenda entre restauração/dente. Em relação às variáveis estudadas, concluiu-se que o CSEB apresentou menores lesões de parede em profundidade e extensão do que os demais SAD, e que os resultados do X-III foram similares estatisticamente ao SBMP para as mesmas variáveis. Quanto a profundidade da lesão externa, todos os SAD tiveram comportamento semelhante. / The aim of this study was to evaluate the in vitro behavior of three dental adhesive systems (DAS), namely the two self etching Clearfil SE Bond Kuraray Co (CSEB) and Xeno III Dentsply (X-III) as well as the three-step etch and rinse Multi-Purpose Plus 3M ESPE (SBMP), concerning the inhibition of secondary dentine caries in the face of a bacterial cariogenic challenge using Streptococcus mutans. Besides the aforementioned material, a negative control group (NC) which did not receive any adhesive treatment was included in this study. The sample, which consisted of human third molars (n=40), in which class-V cavities prepares were restored with the composite resin (CR) Z250 (3M ESPE). An interfacial gap was left between teeth and restorations in the dentinal gingival wall. The four experimental groups (n=10) were exposed to a cariogenic challenge during 30 days. Light Optical Microscopy (LOM) was used to measure wall caries lesion depth, wall caries lesion extension and outer caries lesion depth. SEM (Scanning Electron Microscopy) was the method chosen for the morphological analysis of the formed carie lesions. The data regarding lesions was analyzed through Analysis of Variance and Component of Variance Model in addition to the Brown-Forsythe test at a 5% significance level. The adopted methodology could develop external and wall lesions, also standardizing a gap between restorations and teeth. About the studied variables, it was possible to conclude that CSEB presented the smallest wall lesions both in depth and extension, and the X-III and SBMP results were statistically similar concerning the same variables. Regarding outer lesion depth, all DAS showed similar behaviour.
13

Avaliação cromática de restaurações em resina composta realizadas com diferentes sistemas adesivos e expostas à fumaça do cigarro.

Costa, Leonardo Assis January 2008 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T18:24:48Z No. of bitstreams: 1 Dissertacao - Leonardo Assis Costa.pdf: 5179729 bytes, checksum: 817fc041b92e51f18cdd3caef2d8bc9d (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:06:59Z (GMT) No. of bitstreams: 1 Dissertacao - Leonardo Assis Costa.pdf: 5179729 bytes, checksum: 817fc041b92e51f18cdd3caef2d8bc9d (MD5) / Made available in DSpace on 2013-05-16T18:07:00Z (GMT). No. of bitstreams: 1 Dissertacao - Leonardo Assis Costa.pdf: 5179729 bytes, checksum: 817fc041b92e51f18cdd3caef2d8bc9d (MD5) Previous issue date: 2008 / O manchamento dental pelo cigarro constitui uma das principais queixas dos pacientes fumantes, entretanto a ação do tabaco sobre materiais restauradores estéticos tem sido pouco relatada. Este estudo teve como objetivo avaliar o efeito da fumaça de cigarro, na cor de restaurações em resina composta realizadas com quatro diferentes sistemas adesivos (dois convencionais e dois autocondicionantes). Quarenta terceiros molares humanos foram seccionados no sentido mesio-distal e, posteriormente, preparos circulares foram realizados na junção amelodentinária, das suas respectivas faces vestibular e lingual, com 3mm de diâmetro e 1,5mm de profundidade. Os dentes foram divididos em oito grupos (n=10), de acordo a exposição ou não à fumaça de cigarro e de acordo com o sistema adesivo utilizado (Scotchbond Multi-Uso Plus [SBMP], Adper Single Bond 2 [SB], Clearfil SE Bond [SE], Adper Prompt [AP]), e restaurados com a resina composta (Filtek Z350). Os grupos experimentais foram expostos à fumaça de 1.200 cigarros, 10 cigarros, duas vezes ao dia, por um período de 10 minutos, durante 60 dias consecutivos. As alterações cromáticas foram avaliadas através da análise de fotografias digitais nos tempos: T0 (inicial); T1 (após 30 dias de exposição ao cigarro) e T2 (após 60 dias de exposição ao cigarro). As imagens foram avaliadas com o auxílio do software Adobe Photoshop CS3, considerando os parâmetros de cor do sistema CIE L*a*b* e da diferença total de cor (ΔE’). Os valores médios de ΔE’ e DP para os grupos expostos à fumaça do cigarro ao final do experimento foram: SMPB 23,28 (3,24), SB 27,60 (5,06), SE 26,65 (5,08), AP 27,30 (5,30) (ANOVA/Tukey - p < 0,05). Com base nos resultados pode-se concluir a fumaça do cigarro causou alteração na cor de restaurações em resina composta. Os espécimes restaurados utilizando o SBMP e o SB apresentaram os menores valores de ΔE’. Os espécimes não expostos à fumaça do cigarro e armazenados em água destilada não apresentaram alteração significante nos valores de ΔE’. / Salvador
14

INFLUÊNCIA DO SISTEMA ADESIVO NA COR DE RESINAS COMPOSTAS / INFLUENCE OF THE ADHESIVE SYSTEM IN THE COLOR OF RESIN COMPOSITES

Ritter, Débora Diniz 02 July 2015 (has links)
The aim of this study was to evaluate the influence of different adhesive systems in the color of resin composites with different translucency. Sixty specimens of resin composite, in the shades A2 (n=30) e OA2 (n=30) were made with aid of a metallic mould with 8 mm of intern diameter and 1.25 mm of thickness, and randomly divided according to the adhesive system: two-step etch-and-rinse (Adper Single Bond 2; 3M ESPE), two-step self-etch (Clearfil SE Bond; KURARAY) and universal (Single Bond Universal; 3M ESPE). The materials were applied on the surface of the disk-shaped specimens, simulating direct restorations. The color evaluations were measured with spectrophotometer immediately after the polishing the specimens and after the application of the adhesive systems. The data of CIE L*a*b* system were used for the calculus of ΔE, ΔL, Δa e Δb. Additionally, 5 specimens of each adhesive system were made with the same dimensions of the disks of resin composite for measurement of the L*, a* e b* parameters. The data obtained were subjected to Analysis of Variance and Tukey test (5%). The application of the adhesive system Single Bond Universal on resin composite A2 resulted in highest color change p= 0.000; ΔE = 3.1 ± 0.7). No statistical significant difference was observed among adhesive systems when applied on resin composite shade OA2 (p>0.05). The universal adhesive showed higher trend to green and yellow. In conclusion, the effect of the adhesive system is material-dependent. The adhesive Single Bond Universal results in higher color change when a resin composite with higher translucency is used. / O objetivo deste estudo foi avaliar a influência de diferentes sistemas adesivos na cor de resinas compostas com diferentes translucidez. Sessenta corpos de prova de resina composta Z250 XT (3M ESPE), nas cores A2 (n=30) e OA2 (n=30) foram confeccionados com auxílio de uma matriz metálica com 8 mm de diâmetro interno e 1,25 mm de espessura e divididos aleatoriamente de acordo com o sistema adesivo: convencional de dois passos (Adper Single Bond 2; 3M ESPE), autocondicionante de dois passos (Clearfil SE Bond; KURARAY) e universal (Single Bond Universal; 3M ESPE). Os materiais foram aplicados sobre a superfície dos corpos de prova, simulando restaurações diretas. As avaliações de cor foram mensuradas com espectrofotômetro imediatamente após o polimento dos corpos de prova e posteriormente à aplicação dos sistemas adesivos. Os dados do sistema CIE L*a*b* foram utilizados para o cálculo do ΔE, ΔL, Δa e Δb. Adicionalmente, 5 corpos de prova de cada sistema adesivo foram confeccionados com as mesmas dimensões dos corpos de prova de resina composta para mensuração dos parâmetros L*, a* e b*. Os dados obtidos foram submetidos à Análise de Variância e Teste de Tukey (5%). A aplicação do sistema adesivo Single Bond Universal sobre a resina composta A2 resultou em maior alteração de cor (p = 0,000; ΔE = 3,1 ± 0,7). Nenhuma diferença estatisticamente significante foi observada entre os sistemas adesivos quando aplicados sobre a resina composta cor OA2 (p>0,05). O adesivo universal apresentou maior tendência para o verde e para o amarelo. Em conclusão, o efeito do sistema adesivo na cor das resinas compostas é material dependente. O adesivo Single Bond Universal resulta em maior alteração de cor quando uma resina com maior translucidez é utilizada.
15

RESISTÊNCIA DE UNIÃO DE SISTEMAS ADESIVOS ATUAIS EM DENTINA SUBMETIDA A DIFERENTES TRATAMENTOS / BOND STRENGTH OF ADHESIVE SYSTEMS IN DENTIN SUBMITTED TO DIFFERENT TREATMENTS

Montagner, Anelise Fernandes 17 December 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Studies have shown that the longevity of adhesive restorations is adversely affected by collagen degradation. The purpose of this study was to evaluate the effect of different treatments on the bond strength of adhesive systems in different dentin surfaces. Forty healthy human third molars were randomly assigned to 24 experimental groups (n = 5) according to adhesive systems (Single Bond - SB, Clearfil SE Bond - SE, Adper SE Plus - AP, G Bond - GB), treatments (control and deproteination) and dentin surfaces (proximal, superficial and deep occlusal). For the deproteinization treatment was applied 10% sodium hypochlorite, for 1 minute, to previously conditioned dentin and the adhesive systems were applied according to manufactures directions. In each specimen were made cylindrical cavities in the proximal and occlusal surfaces and, after immersion in destilated water for 24 hours, one slice and 2 slices of occlusal and proximal surfaces were, respectively, obtained. The slices were submitted to push-out test and after it a fracture analysis was performed. The values in MPa were submitted to ANOVA 3-factors and Tukey (p <0.05), indicating a statistically significant difference between the adhesive systems (p = 0.000) and dentin surfaces (p = 0.005), However, the type of treatment (p = 0.058) did not significantly affect the values of bond strength. The bond strength values were higher for proximal surface, followed by superficial oclusal and later by deep occlusal, being influenced by the adhesive system. The collagen removal from the conditioned surface can be considered a way to decrease the sensitivity technique without compromising the adhesive effectiveness. / Estudos têm demonstrado que a longevidade de restaurações adesivas é negativamente afetada pela degradação das fibras colágenas. O objetivo deste estudo foi avaliar o efeito de diferentes tratamentos na resistência de união de sistemas adesivos em diferentes regiões dentinárias. Quarenta dentes terceiros molares humanos hígidos foram alocados randomizadamente em 24 grupos experimentais (n=5) de acordo com: tipo de sistema adesivo (Adper Single Bond - SB, Clearfil SE Bond - SE, Adper SE Plus - AP, G Bond - GB), tipo de tratamento (controle e desproteinização) e tipo de região dentinária (proximal, oclusal superficial e profunda). Para desproteinização da dentina foi utilizado hipoclorito de sódio 10%, por 1 minuto, na dentina previamente condicionada; e os sistemas adesivos foram aplicados conforme indicações dos fabricantes. Cavidades cilíndricas foram realizadas na superfície proximal e oclusal de cada espécime, de onde se obteve, 24 horas após o armazenamento em água destilada, 1 slice e 2 slices, respectivamente. Os slices foram submetidos a teste de push-out e logo após, a análise de fratura. Os valores obtidos em MPa foram submetidos à análise de variância de 3-fatores e teste Tukey (p<0.05), indicando diferenças estatisticamente significantes entre o tipo de sistema adesivo (p=0.000) e o tipo de região dentinária (p=0.005), porém o tipo de tratamento (p=0.058) não afetou significativamente os valores de resistência de união. Os valores de resistência de união foram maiores para superfície proximal, seguida de oclusal superficial e posterior oclusal profunda, sendo influenciados pelo tipo de sistema adesivo. A remoção de colágeno da superfície condicionada pode ser considerada caminho para diminuir a sensibilidade da técnica sem comprometer a efetividade adesiva.
16

Influência de diferentes sistemas adesivos dentários resinosos aplicados em dentina humana frente a um desafio cariogênico bacteriano, in vitro / The influence of different resin dental adhesive systems applied to human dentine in the face of an in vitro bacterial cariogenic challenge, in vitro

Luciana Cardoso Espejo 21 October 2008 (has links)
Neste estudo, o objetivo foi avaliar, in vitro, o comportamento de três sistemas adesivos dentários (SAD), sendo dois autocondicionantes Clearfil SE Bond Kuraray Co (CSEB) e Xeno III Dentsply (X-III) e um condicione e lave de 3 passos Scothbond Multi-Purpose Plus - 3M ESPE (SBMP), no que se refere à inibição de lesões recidivantes de cárie em dentina, frente à um desafio cariogênico bacteriano, que utilizou uma cepa de Streptococcus mutans. Além destes materiais, foi inserido no estudo um controle negativo (CN), o qual não recebeu tratamento adesivo. A amostra formada por terceiros molares humanos (n=40) foi preparada com cavidades Classe V e restaurada com a resina composta (RC) Z250 (3M ESPE), deixando-se um nicho na interface restauração/dente na parede gengival em dentina. Os quatro grupos experimentais (n=10) foram submetidos ao desafio cariogênico para o desenvolvimento das lesões durante 30 dias. Foi realizada em microscopia óptica de luz (MOL) a medição das variáveis: profundidade da lesão de parede, extensão da lesão de parede e profundidade da lesão externa e em MEV (Microscopia Eletrônica de Varredura) a análise morfológica das lesões de cárie formadas. Os dados referentes às lesões foram analisados através de Análise de Variância, testes auxiliares, além do Teste de Brown e Forsythe, com grau de significância de 5%. A metodologia adotada foi capaz de desenvolver lesões externas e de parede e de padronizar uma fenda entre restauração/dente. Em relação às variáveis estudadas, concluiu-se que o CSEB apresentou menores lesões de parede em profundidade e extensão do que os demais SAD, e que os resultados do X-III foram similares estatisticamente ao SBMP para as mesmas variáveis. Quanto a profundidade da lesão externa, todos os SAD tiveram comportamento semelhante. / The aim of this study was to evaluate the in vitro behavior of three dental adhesive systems (DAS), namely the two self etching Clearfil SE Bond Kuraray Co (CSEB) and Xeno III Dentsply (X-III) as well as the three-step etch and rinse Multi-Purpose Plus 3M ESPE (SBMP), concerning the inhibition of secondary dentine caries in the face of a bacterial cariogenic challenge using Streptococcus mutans. Besides the aforementioned material, a negative control group (NC) which did not receive any adhesive treatment was included in this study. The sample, which consisted of human third molars (n=40), in which class-V cavities prepares were restored with the composite resin (CR) Z250 (3M ESPE). An interfacial gap was left between teeth and restorations in the dentinal gingival wall. The four experimental groups (n=10) were exposed to a cariogenic challenge during 30 days. Light Optical Microscopy (LOM) was used to measure wall caries lesion depth, wall caries lesion extension and outer caries lesion depth. SEM (Scanning Electron Microscopy) was the method chosen for the morphological analysis of the formed carie lesions. The data regarding lesions was analyzed through Analysis of Variance and Component of Variance Model in addition to the Brown-Forsythe test at a 5% significance level. The adopted methodology could develop external and wall lesions, also standardizing a gap between restorations and teeth. About the studied variables, it was possible to conclude that CSEB presented the smallest wall lesions both in depth and extension, and the X-III and SBMP results were statistically similar concerning the same variables. Regarding outer lesion depth, all DAS showed similar behaviour.
17

AVALIAÇÃO DA EVAPORAÇÃO DO SOLVENTE DE SISTEMAS ADESIVOS CONTEMPORÂNEOS / ASSESSMENT OF SOLVENT EVAPORATION OF CONTEMPORARY ADHESIVES SYSTEM

Werle, Stefanie Bressan 09 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objectives: The aim of this study was to evaluate the effect of air-drying time on degree of evaporation of solvent (DE), microtensile resin-dentin bond strength (μTBS) and degree of conversion (DC) of adhesive systems. Methods: Four two-steps etch-and-rinse (Adper Single Bond 2, XP Bond, Prime & Bond 2.1 and Opti Bond Solo) and one one-step self-etch (Adper Easy One) were tested. The DE was measured gravimetrically (n=6) after 3, 5, 10, 20, 30 and 60 seconds by air-drying. For μTBS flat dentin surfaces were obtained from fifty caries-free extracted molars (n=5). The adhesive systems were applied to dentin surfaces according to the manufacturer s instructions and subsequently air-drying for the time proposed by manufacturer (A) or for prolonged time (B), corresponding to maximum DE in the times evaluated. A composite resin was used for coronal build-up. After 24h water storage at 37ºC, the specimens were sectioned in x and y directions to obtain bonded sticks (0.9 mm2) which were immediately subjected to μTBS (1mm/min). The DC (n=3) was calculated by Fourier-transform infrared spectroscopy with attenuated total reflectance considering air-drying times A and B. The data of DE were statistically analyzed by ANOVA and Tukey´s test, μTBS and DC were analyzed by T-Test (α = 0.05). Results: The prolonged time (B) increased the DE for all materials compared to manufacturer´s times, however improved μTBS only for XP Bond and Adper Easy One. DC was not affected by evaluated air-drying times. There was no significant correlation between DC and μTBS. Conclusion: The evaporation of solvent from adhesive systems is affected by air-drying. The effect of air-drying time seems be material-dependent on parameters evaluated. Changes in protocols of use may be necessary to obtain better properties. / Objetivos: Avaliar o efeito de diferentes protocolos de aplicação de jato de ar no grau de evaporação do solvente (GE), resistência de união à dentina (RU) e grau de conversão (GC) de sistemas adesivos. Métodos: Quatro sistemas adesivos de dois passos com condicionamento ácido prévio (Adper Single Bond 2, XP Bond, Prime & Bond 2.1 e Opti Bond Solo) e um autocondicionante de passo único (Adper Easy One) foram testados. O GE foi mensurado gravimetricamente (n=6) após a aplicação de jato de ar durante 3, 5, 10, 20, 30 e 60 segundos. A RU à dentina foi mensurada através do teste de microtração. Para isso, cinquenta molares humanos hígidos (n=5) tiveram o esmalte e dentina superficial removidos. Os sistemas adesivos foram aplicados de acordo com as instruções dos fabricantes na superfície dentinária e subsequentemente foi aplicado jato de ar durante o tempo proposto pelo fabricante (A) ou por tempo prolongado (B), o qual resultou em evaporação máxima nos tempos considerados na avaliação do GE. Após a confecção de blocos de resina composta e armazenamento em água à 37ºC, por 24 horas, os espécimes foram seccionados em dois eixos a fim de obterem-se espécimes com área de secção transversal de aproximadamente 0,9 mm2. Os espécimes foram submetidos ao teste de microtração com velocidade de 1mm/min. O GC (n=3) foi analisado por espectroscopia de infravermelho transformada de Fourier (FTIR) considerando os tempos A e B. Os dados do GE foram submetidos à análise de variância de um fator e teste de Tukey. Os dados de RU e GC foram submetidos ao teste t de Student pareado. Todas as análises foram realizadas considerando o nível de significância de 5%. Resultados: A aplicação de jato de ar por tempo prolongado (B) aumentou o GE para todos os materiais em comparação ao tempo proposto pelo fabricante. Contudo, maiores valores de RU foram obtidos somente para os sistemas XP Bond e Adper Easy One. O GC não foi afetado pelos tempos de aplicação de jato de ar avaliados. Não houve correlação significante entre GC e RU. Conclusão: A evaporação do solvente dos sistemas adesivos testados é modulada pelo tempo de aplicação de jato de ar. A influência do tempo de aplicação do jato de ar nos parâmetros testados parece ser material dependente. Mudanças no protocolo de aplicação jato de ar podem ser necessárias a fim de se obterem as melhores propriedades dos sistemas adesivos.
18

Análise in vitro do efeito inibitório de restaurações contendo o monômero antibacteriano MDPB na progressão de cáries secundárias em raizes dentárias / in vitro analysis of inhibitory effects of the antibacterial monomer MDPBcontaining restorations on the formation of secondary root caries

Thomé, Thaís 02 July 2009 (has links)
Este estudo teve por objetivo analisar in vitro o efeito inibitório de materiais res tauradores contendo o monômero ant ibac ter iano brometo de metacriloiloxidodecilpiridínio (MDPB) no desenvolvimento de lesões de cárie secundária em raízes dentárias submetidas a um desafio cariogênico. Cavidades com características de cavidades classe V (2 mm x 2mm) foram preparadas em setenta e cinco fragmentos de raízes dentárias humanas. As amostras foram divididas aleatoriamente em 5 grupos (n=15 amostras/grupo) e restauradas como segue: (I) sistema adesivo sem MDPB + resina composta sem MDPB (controle negativo); (II) cimento de ionômero de vidro resino-modificado (CIV-RM, controle positivo); (III) sistema adesivo sem MDPB e resina composta com MDPB (2,83% MDPB); (IV) sistema adesivo contendo MDPB e resina composta sem MDPB; e (V) sistema adesivo contendo MDPB e resina composta contendo MDPB. Lesões de cárie secundária radicular foram produzidas utilizando-se um modelo bacteriológico de indução de cáries artificiais. As amostras restauradas foram imersas em um meio de cultura contendo Streptococcus mutans e sacarose por 15 dias. Fatias (80 ± 20 m) das amostras foram utilizadas para a mensuração da média das profundidades das lesões formadas adjacentes à ambas as margens das restaurações através de microscopia de luz polarizada. Os resultados foram expressos em porcentagem relativa à média de profundidade encontrada no grupo controle negativo (GI), que foi considerado 100%. Os dados foram comparados por ANOVA complementada pelo teste de Tukey (p0.05). As profundidades das lesões adjacentes às cavidades preenchidas com CIV-RM (GII; 85,17 ± 15,2%) foram significantemente (p < 0.01) menores que as profundidades das cavidades adjacentes às restaurações realizadas com resina composta sem MDPB (GI; 100,00 ± 10,04%). As profundidades das lesões adjacentes às cavidades restauradas com resina contendo MDPB (GIII; 82,68 ± 12,81% e GV; 85,65 ± 15,42%), independentemente do sistema adesivo utilizado, foram similares àquelas do CIV-RM (GII). A média das profundidades das lesões nestes grupos diminuiu 13% (GV) e 17% (GIII) em relação ao controle negativo (GI). Portanto, nas condições deste estudo, sugerimos que a resina composta contendo o monômero antibacteriano MDPB é capaz de inibir o avanço de lesões de cárie secundária em raízes dentárias. / This in vitro study aimed to analyze the potential of restorative materials containing the antibacterial monomer 12-methacryloyloxydodecylpyridinium bromide (MDPB) for controlling the advance of bacterial induced secondary root caries-like lesions. Class V cavities (2 mm x2 mm) were prepared in seventy-five human root fragments. Specimens were randomly divided in 5 groups (n=15 fragments per group) and restored as follows: (I) MDPB-free adhesive system + MDPB-free composite (negative control); (II) resin modified glass ionomer (RM-GIC; positive control); (III) MDPB-free adhesive system + MDPB-containing composite (2.83% MDPB); (IV) MDPB-containing adhesive system + MDPB-free composite; (V) MDPB-containing adhesive system + MDPB-containing composite. Artificial secondary root caries lesions were produced by a biological artificial caries challenge. The restored specimens were immersed into a culture medium containing Streptococcus mutans and sucrose for 15 days. Histological slices (80 ± 20 m) of the specimens were used for measuring the mean depths of the artificial lesions produced in both margins of the restorations using polarized light microscopy. Results were expressed in percentage related to the mean depth of the negative control, considered 100%. Data were compared by ANOVA followed by the Tukeys test (p 0.05). The depths of lesions adjacent to cavities filled with RM-GIC (GII; 85.17 ± 15.2%) were significantly (p < 0.01) shallower than those adjacent to restorations with MDPB-free composite (GI; 100.00 ± 10.04%), despite the presence of MDPB in the adhesive system (GIV; 101.95 ± 21.32%). The depths of lesions adjacent to cavities restored with MDPBcontaining 3 composite (GIII; 82.68 ± 12.81%and GV; 85.65 ± 15.42%), despite the adhesive system used, were similar to those of RM-GIC (GII). Mean lesions depths in these groups decreased 13% (GV) to 17% (GIII) in relation to the negative control (GI). Concluding, MDPB-containing composite inhibits the progression of artificial secondary root caries lesions regardless of adhesive systems.
19

Efeito da base de cimento de ionômero de vidro convencional e modificado por resina na interface adesiva dente/resina composta após termociclagem / Effect of conventional and resin-modified glass ionomer cements base on tooth/composite resin adhesive interface after termocycling

Sampaio, Paula Costa Pinheiro 24 April 2009 (has links)
Resinas compostas apresentam contração de polimerização e a tensão gerada durante essa polimerização compete com a força adesiva na interface dente/restauração. A técnica incremental e o uso de bases com alta resiliência e módulo de elasticidade próximo ao das estruturas dentárias são técnicas desenvolvidas para tentar diminuir a tensão originada pela contração de polimerização. O presente estudo teve como objetivo analisar a influência do uso de bases de cimento de ionômero de vidro convencional e modificado por resina na qualidade e adaptação marginal na interface dentina/resina composta, após a ciclagem térmica, usando testes de resistência adesiva e análise em microscopia confocal de varredura a laser. Foram confeccionadas cavidades na face oclusal (4,5mm x 3mm x 5mm) de 60 molares humanos extraídos divididos em 6 grupos: 1 e 4 - sistema adesivo (AdperTM Single Bond; 3M ESPE) + resina composta (Filtek Z250; 3M ESPE); 2 e 5 - base de cimento de ionômero de vidro convencional (Ketac Molar Easymix; 3M ESPE) + sistema adesivo + resina composta; e 3 e 6 - base de cimento de ionômero de vidro modificado por resina (Vitrebond; 3M ESPE) + sistema adesivo + resina composta. Os grupos 4, 5 e 6 sofreram um processo de termociclagem com dois banhos (5ºC 55ºC) durante 30 segundos em 5.000 ciclos. Após 24 horas, os dentes foram seccionados em uma máquina de cortes com disco de diamante em espessura de 0,8mm. Uma fatia de cada dente foi separada aleatoriamente para análise em Microscópio Confocal para observação e mensuração de possíveis fendas marginais internas. As demais fatias foram seccionadas para a confecção de palitos (0,8mm X 0,8mm) que foram submetidos a testes de microtração em uma máquina de ensaios universal EMIC. Os resultados de resistência adesiva foram submetidos à análise de variância a um critério (ANOVA) e ao teste t-Student (p< 0,05). A presença de fendas foi avaliada com o teste da razão de verossimilhança ou teste exato de Fisher e os valores de comprimento das fendas foram avaliados pelo teste não paramétrico de Kruskal-Wallis (p<0,05). Não foram observadas diferenças estatisticamente significantes na resistência adesiva em nenhum dos grupos sem termociclagem (G1 19,28 MPa; G2 16,29 MPa; e G3 15,95MPa) ou com termociclagem (G4 19,74 MPa; G5 16,58 MPa; e G6 16,01 MPa). A análise das medidas das fendas revelou não haver diferença estatisticamente significante entre os grupos G1 (1,4µm), G2 (2,88µm) e G3 (4,63µm) e entre os grupos G4 (4,2µm), G5 (12,5µm) e G6 (5,4µm). No entanto, a termociclagem determinou um aumento do tamanho médio das fendas no grupo com base de CIV convencional (G4 12,5µm). A análise da presença ou ausência de fendas mostrou um aumento na porcentagem do número de fendas quando os espécimes foram termociclados, para os grupos sem base e com base de CIV (G1 - 30%; G2 - 25% G3 25%; G4 - 53,33%; G5 70%; e G6 30%). Os resultados mostraram, ainda, não haver relação entre o comprimento e a formação das fendas com a resistência adesiva. Conclui-se, portanto, que o uso de base de cimento de ionômero de vidro modificado por resina mantém mais estável a qualidade da interface adesiva dentina/resina composta após envelhecimento artificial com termociclagem. / Polymerization shrinkage leads to a tension into dentin/resin composite interface that can cause marginal discoloration, poor marginal adaptation, secondary caries and post-operative sensitivity. The incremental restorative technique and the use of a resilient liner with a modulus of elasticity similar to dental structures are techniques used to decrease the shrinkage polymerization tension. The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the adhesive interface dentin/resin of occlusal restorations after thermocycling aging. Occlusal cavities were prepared sixty human extracted molars, divided into six groups: 1 and 4 with no liner; 2 and 5 glass-ionomer cement (Ketac Molar Easymix); and 3 and 6 resin-modified glass-ionomer cement (Vitrebond). Resin composite (Filtek Z250) was placed after application of adhesive system Adper Single Bond 2. Adhesive system was mixed with fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. After that, the specimens of groups 4, 5, 6 were thermocycled into 2 baths (5ºC 55ºC) of 30s each in 5.000 cycles. After this period, teeth were sectioned in 0,8mm slices. One slice of each tooth was randomly selected for analysis in Confocal Microscopy. The other ones were sectioned in sticks, which were submitted to micro-tensile test. The results of adhesive strength were analyzed by one way ANOVA and t-Student tests. Gap formation were analysed by Fisher test and the gaps size were analyzed by Kruskal-Wallis test (p<0,05). No statistical difference on adhesive resistance was showed between groups. Confocal Microscopy analysis showed gaps with a higher mean sizes for group 4 (12,5µm) and higger percentage of marginal gaps formation for the thermocycled groups (G1 - 30%; G2 - 25%; G4 - 53,33%; G5 70%). Groups 3 (25%) and 6 (30%) showed the lowest percentage of marginal gap formation. The results revealed that gap formation is not related to adhesive strength. It can be concluded, therefore, that the use of a resin-modified-glassionomer cement liner showed less gap formation on dentin/composite adhesive interface after artificial aging compared to conventional glass ionomer cement liner and restorations with no lining.
20

Influência de variáveis metodológicas no valor da resistência de união material adesivo/substrato dentinário e, no padrão de fratura: ensaio de \"micro\" cisalhamento / Methodological variables influence on bonding of adhesive material/dentin substrate and fracture pattern micro shear test

Andrade, Andréa Mello de 10 December 2010 (has links)
A influência de variáveis metodológicas no valor da resistência de união e no padrão de fratura, por ensaio de microcisalhamento, foi verificada em dentina planificada de molares humanos e estudada em quatro diferentes experimentos, nos quais dois sistemas adesivos foram utilizados (Adper Single Bond 2 e XP Bond) e uma resina composta (Filtek Z250). Foram eles: Experimento 1- momento de fotoativação do adesivo: antes ou após o posicionamento das cânulas sobre o substrato dentinário; Experimento 2- tempo de armazenagem: 10min, 24 horas, 48 horas e 7 dias em água destilada a 37oC; Experimento 3- área de secção transversal dos corpos de prova: 0,44mm2, 0,82mm2, 1,98mm2 e 4,44mm2; Experimento 4- momento de fotoativação da resina / remoção da cânula para o ensaio. Os dados obtidos de resistência de união, em MPa, foram tratados por métodos de ANOVA. Os corpos de prova resultantes de todos os experimentos foram observados em microscopia eletrônica de varredura e analisados de forma qualitativa quanto ao modo de fratura. Houve diferença significativa no Experimento 1, sendo que os valores médios de resistência de união foram mais altos quando os adesivos foram fotoativados antes de posicionar as cânulas. Não houve diferença estatisticamente significante para as variáveis tempo de armazenagem e sistema adesivo (Experimento 2), e nem para as variáveis área de secção transversal e sistema adesivo estudadas (Experimento 3). Para o Experimento 4, houve diferença estatisticamente significante para a condição experimental resina fotoativada e remoção da cânula quando previamente realizada à adesão ao substrato e entre os adesivos. Em todos os experimentos o modo de fratura foi predominantemente adesivo/misto. Concluiu-se que algumas variáveis do método são fundamentais para sua padronização, pois com base nos resultados deste estudo elas influenciam os valores médios da resistência de união. / The effect of methodological variables on the microshear bond strength and fracture pattern was assessed in flat human molars dentin in four different experiments using two adhesive systems (Adper Single Bond 2 and XP Bond) and a composite resin (Filtek Z250). The experiments were: 1. Adhesive light activation moment prior or after mold positioning on dentin; 2. Storage period 10 min, 24h, 48h or 7 days in distilled water at 37oC; 3. Mold transversal section area 0.44mm2, 0.82mm2, 1.98mm2 and 4.44mm2; 4. Resin light activation moment with or without mold removal prior to testing. Mean data values (MPa) were subjected to ANOVAs methods. All fractured specimens were qualitatively analyzed in SEM to verify the fracture mode. Regarding Experiment 1 a significative difference was shown for the main factor Adhesive Light Activation Moment; higher bond strength values were achieved with adhesive system ligth activated before mold positioning. No significant differences were found for storage period or section area analyzed on Experiments 2 and 3, respectively. The main factor Resin Light Activation Moment presented differences when the resin composite was previously light activated and mold was removed prior to bonding the resin with the adhesive systems. In all experiments, mode of failure was predominantly adhesive/mixed. The conclusion is that some variables of the method are essential for its standardization, given that they influence the bond strength values.

Page generated in 0.5363 seconds