• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 218
  • 20
  • 18
  • 18
  • 18
  • 18
  • 2
  • 1
  • 1
  • Tagged with
  • 225
  • 225
  • 225
  • 68
  • 57
  • 52
  • 51
  • 51
  • 30
  • 30
  • 28
  • 27
  • 22
  • 21
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Análise comparativa da qualidade posicional dos métodos de posicionamento por ponto preciso e do posicionamento relativo estático com GNSS / Comparative Analysis of positional quality methods of precise point positioning and relative positioning static with GNSS

Almeida, Marília Sanglard 23 February 2015 (has links)
Made available in DSpace on 2015-03-26T13:28:36Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1996865 bytes, checksum: 80a7a778bb6c66c23c06d757b2a4c310 (MD5) Previous issue date: 2015-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Among the technologies of spatial positioning, highlight the GNSS (Global Navigation Satellite System), which is widely used in various applications in the area of Geodesy, among others. The precise point positioning (PPP) has been shown to be a powerful tool for geodetic and geodynamics. applications Relative positioning is still the most widely used method for determination of coordinates in precision geodetic surveys. However, the PPP is increasingly in evidence and has provided satisfactory results. Given the above, remains to be seen, among the techniques mentioned, which provides more accurate results currently. The data used in this study were collected by the stations of RBMC (Brazilian Network for Continuous Monitoring of GNSS Systems) provided by IBGE (Brazilian Institute of Geography and Statistics), for the date January 01, 2014. For PPP analysis was used the free service online IBGE-PPP, and for analysis of static relative positioning was used the free online placement service AUSPOS, that processes network data, using the scientific software Bernese, and commercial software LGO (Leica Geo Office), which was used for processing single baselines and multiple baselines (vector adjustment).The GPS data were processed by varying the trace interval, covering the intervals of 1, 2, 4, 6, 8, 10 and 12 hours. In IBGE-PPP and AUSPOS the results provided was referenced to IGb08 (ITRF2008) at the time of data collection. To process the data in the LGO, the coordinates of the base stations, available in SIRGAS2000, epoch 2000.4, were transformed and updated to the reference system IGb08 (ITRF2008) at the time of data collection.Thus, the estimated coordinates at LGO were also estimated in IGb08 at the time of data collection. In sequence, the coordinates estimated in LGO, IBGE-PPP and AUSPOS were compared with the coordinates provided in descriptive of RBMC stations,which were also transformed and updated to the same reference system and time of coordinates estimated. With that, the movement of tectonic plates over time was minimized. In this way, from the calculation of discrepancies (trends) and with the clarifications provided in the adjustment, it was possible to perform the calculation of accuracies. According to the results, it was concluded that the method of relative positioning with the use of computational application and commercial use of receivers of dual frequency continues to be the most accurate method, regardless of the length of the baseline. The performance of relative positioning with a frequency receivers, involving short baselines also showed excellent results. In this case, at 64.3% of the results the accuracy was millimeter. It should be noted the potential of the IBGE-PPP and AUSPOS, which showed good results. In addition, these processing services are free and the users need only a receiver. / Dentre as tecnologias espaciais de posicionamento, destaca-se o GNSS (Global Navigation Satellite System), que é amplamente empregado em diversas aplicações na área de Geodésia, entre outras. O Posicionamento por Ponto Preciso (PPP) tem se mostrado uma poderosa ferramenta para aplicações geodésicas e geodinâmicas. O posicionamento relativo é ainda o método mais utilizado para determinação de coordenadas em levantamentos geodésicos de precisão. Contudo, o PPP está cada vez mais em evidência e tem proporcionado resultados satisfatórios. Diante do exposto, resta saber, dentre as técnicas mencionadas, qual apresenta resultados mais acurados atualmente. Os dados utilizados neste trabalho foram coletados pelas estações da RBMC (Rede Brasileira de Monitoramento Contínuo dos Sistemas GNSS) disponibilizados pelo IBGE (Instituto Brasileiro de Geografia e Estatística), referentes à data 01 de janeiro de 2014. Para análise do PPP foi utilizado o serviço gratuito online IBGE-PPP, e para análise do posicionamento relativo estático foram utilizados o serviço de posicionamento online gratuito AUSPOS, que processa os dados em rede, com uso do software científico Bernese, e o software comercial LGO (Leica Geo Office), que foi utilizado para processamento de linhas de base simples e de múltiplas linhas de base (ajustamento vetorial). Os dados GPS foram processados variando o intervalo de rastreio, abrangendo os intervalos de 1, 2, 4, 6, 8, 10 e 12 horas. No IBGE- PPP e no AUSPOS os resultados fornecidos são referenciados ao IGb08 (ITRF2008) na época de coleta dos dados. Para o processamento dos dados no LGO as coordenadas das estações base, disponibilizadas em SIRGAS2000, época 2000,4, foram transformadas e atualizadas para o sistema de referência IGb08 (ITRF2008) na época de coleta dos dados. Assim, as coordenadas estimadas no LGO também foram estimadas no IGb08 na época de coleta dos dados. Na sequência, as coordenadas estimadas no LGO, IBGE-PPP e AUSPOS foram comparadas com as coordenadas disponibilizadas nos descritivos das estações da RBMC, que também foram transformadas e atualizadas para o mesmo sistema de referência e época das coordenadas estimadas. Com isso, o deslocamento das placas tectônicas ao longo do tempo foi minimizado. Desta forma, a partir do cálculo das discrepâncias (tendências) e com as precisões disponibilizadas no ajustamento, foi possível realizar o cálculo das acurácias. De acordo com os resultados obtidos, conclui-se que o método de posicionamento relativo com o uso de aplicativo computacional comercial e uso de receptores de dupla frequência continua sendo o método mais acurado, independentemente do comprimento da linha de base. A performance do posicionamento relativo com receptores de uma frequência, envolvendo linhas de base curtas, também apresentou ótimos resultados. Neste caso, em 64,3% dos resultados a acurácia foi milimétrica. Deve-se salientar a potencialidade do IBGE-PPP e do AUSPOS, que apresentaram bons resultados. Além disso, esses serviços de processamento são gratuitos e o usuário deve dispor de apenas um receptor.
162

Influência de diferentes condições da ionosfera no posicionamento por ponto com GPS : avaliação na região brasileira /

Matsuoka, Marcelo Tomio. January 2007 (has links)
Orientador: Paulo de Oliveira Camargo / Banca: João Francisco Galera Monico / Banca: Márcio H. O. Aquino / Banca: Inez Staciarini Batista / Banca: Claudio Antonio Brunini / Após a desativação da técnica SA, a ionosfera tornou-se a principal fonte de erro no posicionamento com GPS. O erro associado à ionosfera é diretamente proporcional ao conteúdo total de elétrons (TEC - Total Electron Content) presente ao longo do caminho da trajetória percorrida pelo sinal na ionosfera e inversamente proporcional ao quadrado da freqüência do sinal. O TEC, e conseqüentemente o erro devido à ionosfera, variam no tempo e no espaço e é influenciado por diversas variáveis, tais como: ciclo solar, época do ano, hora do dia, localização geográfica, atividade geomagnética, entre outros. A região brasileira é um dos locais que apresenta os maiores valores e variações espaciais do TEC e onde estão presentes diversas particularidades da ionosfera, tais como, a anomalia equatorial e o efeito da cintilação ionosférica. Desta forma, é importante a realização de pesquisas que visam estudar o comportamento do TEC, e conseqüentemente do erro devido à ionosfera no Brasil, que é um trabalho complexo devido aos diversos fatores que influenciam a variação do TEC, além das particularidades presentes na região brasileira. Estudos desta natureza podem auxiliar a comunidade geodésica brasileira, e demais usuários do GPS, no entendimento das limitações impostas pela ionosfera nas regiões de interesse. Devido à natureza dispersiva da ionosfera, o estudo do comportamento do TEC no Brasil pode ser realizado utilizando os dados GPS de receptores de dupla freqüência pertencentes à RBMC (Rede Brasileira de Monitoramento Contínuo). Adicionalmente, para uma melhor análise, pode-se também utilizar dados das estações da rede IGS (International GNSS Service) da América do Sul. / In the SA absence, the ionosphere is the largest error source in GPS positioning. The error due to the ionosphere in the GPS observables depends on the signal frequency and Total Electron Content (TEC) in the ionospheric layer. The TEC varies regularly in time and space in relation to the sunspot number, the season, the local time, the geographic position, and others. The Brazilian region is one of the regions of the Earth that presents largest values and space variations of the TEC, being influenced by the equatorial anomaly of ionization and ionospheric scintillation. Therefore, it is important to study the TEC behavior in the Brazilian region. Due to the ionosphere dispersive nature, the TEC behavior in Brazil can be studied using GPS data from RBMC (Rede Brasileira de Monitoramento Contínuo - Brazilian Network for Continuous Monitoring of GPS). Additionally, GPS data from IGS (International GNSS Service) network of the South America can also be used in the experiments. / Doutor
163

Determinação de órbitas com o GPS através de mínimos quadrados recursivo com rotações de Givens /

Silva, Aurea Aparecida da. January 2001 (has links)
Resumo: O Sistema de Posicionamento Global oferece um poderoso e relativamente barato processo para se determinar órbitas de satélites artificiais da Terra. Este trabalho apresenta um método de determinação de órbita para satélites com um receptor GPS a bordo. Medidas de pseudo-distância são usadas para estimar o vetor de estado. O estimador considerado é o método dos mínimos quadrados recursivo, através de rotações ortogonais de Givens, com a finalidade de evitar problemas numéricos e de inversão de matrizes. É considerado a modelagem das forças devido ao geopotencial de alto grau e ordem. Resultados indicam que a precisão em posição melhor que 10 m foi obtido usando dados reais do satélite Topex (com um mínimo de duas horas de dados - aproximadamente um período orbital). O resíduo de pseudo-distância teve um desvio padrão cerca de 5 m. / Abstract: The Global Positioning System is a powerful and low cost process to compute orbits for some artificial Earth satellites. This work presents a method of orbit determination for satellites with an onboard GPS receiver. Pseudo-ranges are used in the measurements equations for the orbit estimator. The estimator considered is the recursive least squares method, numerically improved with orthogonal Givens rotations and thus avoiding problems concerning inversion of matrices. Up to high order geopotential perturbations are taken into account. Results indicate that precision better than 10 m is easily obtained using batches of one orbital period for the TOPEX satellite (two hours of orbital period). Standard deviation of about 5 m resulted for the residuals. / Orientador: Rodolpho Vilhena de Moraes / Coorientador: Hélio Koiti Kuga / Mestre
164

Mapeamento da variabilidade espacial da produção na cafeicultura de montanha / Mapping of spatial variability of the mountain coffee production

Oliveira, Alisson Sanguinetti Cruz de 31 October 2003 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-21T10:19:51Z No. of bitstreams: 1 texto completo.pdf: 4752674 bytes, checksum: 268d2f80042ae4f4982c341e76a02d1b (MD5) / Made available in DSpace on 2017-02-21T10:19:51Z (GMT). No. of bitstreams: 1 texto completo.pdf: 4752674 bytes, checksum: 268d2f80042ae4f4982c341e76a02d1b (MD5) Previous issue date: 2003-10-31 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Propôs-se uma metodologia para mapear variabilidade espacial da maturação dos frutos, produtividade e qualidade de café de montanha durante a safra 2002/3 em uma propriedade cafeeira no Município de Viçosa, Estado de Minas Gerais, Brasil. Nesta propriedade cultiva-se Coffea arabica L. cv. Catuaí Vermelho, linhagem IAC H2077-2-5-44, e predomina relevo montanhoso. Dividiu-se a metodologia em três etapas principais: anterior à colheita, de colheita e após a colheita. Na etapa anterior à colheita, georreferenciaram-se, codificaram-se e rotularam-se cafeeiros em um talhão de cerca de um hectare. Na etapa de colheita, dividida em catação e colheita final conforme cronograma da propriedade, pesaram-se e amostraram-se todas as medidas colhidas no talhão, 129 na catação e 339 na colheita final. Na etapa após a colheita dividiu-se cada amostra conforme estádio de maturação, pesaram-se esses frutos e determinaram-se umidades médias diárias desses frutos. Os cafés cereja de cada amostra da catação foram secos, beneficiados e classificados. Mapearam-se, com interpolação pelo método do Inverso do Quadrado da Distância, a maturação dos frutos, produtividade e qualidade dos grãos e da bebida. A partir dos resultados e análises dos mapas, obteve-se a variabilidade espacial da umidade dos tipos de fruto, maturação, produtividade e qualidade do café. A maturação dos tipos de fruto variou durante a colheita, sendo que suas umidades reduziram-se progressivamente ao longo da safra e apresentaram valores médios distintos para cada estádio de maturação. Na catação, a produtividade do café em coco, corrigido para 11% b.u., variou de 842,33 a 8.126,87 kg/ha, com coeficiente de variação de 19,86%; e, na colheita final, de 948,82 a 16.269,20 kg/ha, com coeficiente de variação de 27,36%. A produtividade total variou de 3.431,66 a 18.662,90 kg/ha, com coeficiente de variação de 19,46%. Quanto à qualidade, tenderam a variar o tipo e a descrição peneira dos grãos, e alguns componentes da descrição bebida. Classificaram-se as amostras em tipo 5, 5/6 (65,89% das amostras) ou 6. A descrição peneira dos grãos variou entre 19, 18, 17, 16, 14, Moca e Fundo. Houve variações nos componentes da bebida (aroma, sabor, acidez e corpo), mas todas as amostras foram classificadas como de bebida Estritamente Mole. A metodologia proposta permitiu mapear a variabilidade da produtividade, porém, a dificuldade da definição da área de influência de cada saco colhido resultou em valores de produtividade irreais em alguns pontos, demandando futuros estudos na definição dessa área e, ou, em metodologias de filtragem dos dados. / A method was proposed to map spatial variability of the fruit ripennes, yield and quality of mountain coffee during the 2002/3 harvest. This work took place at Fazenda Laje, a coffee farm, and at the Departament of Agricultural Engineering of Universidade Federal de Viçosa, in the City of Viçosa, State of Minas Gerais, Brazil. In this farm Coffea arabica L. cv. Catuaí Vermelho, IAC H2077-2-5-44 lineage has been cultivated, and predominates mountainous landscape. The method was divided in three main steps: before-harvest, harvest and post-harvest. In the before-harvest step, the coffee plants were georefferenced using a DGPS, codified and labeled with a code in a field of about one hectare. In this field, plant spacing, ages, heights, number of leaves and vigor were variable. In the harvest step, divided in selective harvest and final harvest as of the farm calendar, all the bags harvested in the field were weighed and sampled, 129 in selective harvest and 339 in the final harvest. In the post-harvest step, the samples were sorted based on fruit ripennes and each fraction was weighed. Daily, it was determined moisture content average of each fraction. The ripe coffee sample fruit of the selective harvest was hulled (parchment coffee), dried, processed (green coffee) and classified. It was built maps of the fruit ripennes, yield and quality by using the interpolation method of the Inverse Distance Squared. The mass percentage of in each maturation stage was variable during the harvest and their moisture contents were reduced progressively along the harvest and presented different average values to each maturation stage. In the selective harvest, the yield, at 11% w.b., ranged from 842.33 to 8,126.87 kg/ha, with coefficient of variation of 19.86%; and, in the final harvest, from 948.82 to 16,269.20 kg/ha, with coefficient of variation of 27.36%. The total yield ranged from 3,431.66 to 18,662.90 kg/ha, with coefficient of variation of 19.46%. About the quality, tended to vary the type and size of the coffee grains, and some components of the coffee drink. The samples were classified in type 5, 5/6 (65.89% of the samples) or 6. The description size of the grains varied among 19, 18, 17, 16, 14, "Moca" and "Fundo". Although variations in the components of the drink (smell, taste, acidity and body), all the samples were classified as of "bebida Estritamente Mole" that is the best drinking taste. The proposed methodology allowed to mapping the coffee yield, however, because of the difficult for defining the area of influence of each sample, it resulted unreal yield at some points. Some further studies should be done in order to better define the area of influence and, or, to use some filtering data methodology. / Dissertação importada do Alexandria
165

Desenvolvimento de um sistema informatizado de menor custo para aquisição e armazenamento de dados de sensores analógicos e receptor GPS

Guerra, Saulo Philipe Sebastião [UNESP] 24 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-24Bitstream added on 2014-06-13T18:42:20Z : No. of bitstreams: 1 guerra_sps_dr_botfca.pdf: 635286 bytes, checksum: 80854b4b654b2f791c478ac607643dd8 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Universidade Estadual Paulista (UNESP) / Precision agriculture is the integration among several technologies in order to reduce the agricultural losses, increasing the economical return and reducing the environmental impacts. So, the computer based data acquisition and storage for field data is very important for precision agriculture development. The automatic data storage allows to eliminate the human reading and type errors, to reduce data losses and no synchronism readings among different sensors, in addition assure different frequency readings with precise intervals This present research had for main objective to develop and evaluate a data acquisition and storage system based on personal computer for analogical sensor (load cells and potentiometer) and GPS receiver (Global Positional System). The main objective of this research was to develop and evaluate a low cost acquisition and storage data system for analogical sensors (load cells and potentiometer) and GPS receiver and also realize a comparative economical analysis between the actual data acquisition system (Micrologger CR10X) and the proposal system.
166

Precisão de planta planialtimétrica gerada por modelagem numérica de superfície a partir de coordenadas UTM plano retangulares coletadas em receptor GPS topográfico

Rodrigues, Ramon Juliano [UNESP] 07 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-07Bitstream added on 2014-06-13T18:21:00Z : No. of bitstreams: 1 rodrigues_rj_me_botfca.pdf: 902601 bytes, checksum: 9baea22d312bae3968d03e4330aa0117 (MD5) / Universidade Estadual Paulista (UNESP) / O planejamento de atividades em áreas, notadamente em áreas extensas como o caso canaviais, rurais é inegavelmente melhor dimensionado quando se tem em mãos acuradas plantas planialtimetricas. Em que use a existência de cartas oficiais, como são exemplos as cartas do IBGE e as cartas do plano Cartográfico do Estado de São Paulo, não raras vezes o planejador necessitsa de maior acuracidade no que diz respeito à equidistância vertical entre curvas. O tradicional levantamento topográfico convencional embora apresente excelente resultado, tem como inconveniência o tempo dispendido e custos. Dentro desse contexto, foi desenvolvido o presente projeto que teve como objetivo constatar a acurácia de carta de relevo obtida pelo sistema de posicionamento global, tendo como testemunha cordões de contorno precisamente locados através de método geométrico. Paralelamente o presente projeto teve também por objetivo comparar diferenças de área segundo superfície em plano e inclinado calculado segundo métodos eletrônico e manual e a possível influência do relevo na estimativa de produção de cana-deaçúcar. 2 Os resultados obtidos mostram, que os dados coletados por um receptor GPS topográfico Pró XR Trimble permitiram a geração de planta planialtimétrica com equidistância vertical de 1,0 metro cuja precisão foi compatível com o relevo real de campo, pelo que se pode sugerir a utilização do método como sustentação ao planejamento de projetos agrícolas. Foi também possível constatar que as metodologias adotadas para cálculo de área considerando plano inclinado (X Y Z) nos métodos manual e eletrônico, proporcionaram os mesmos resultados sendo que ambos apresentaram diferença de 0,27% com relação à respectiva projeção horizontal o que não explica a diferença entre a produção estimada e real geralmente ao redor de 5,0 %, segundo a Associação dos Plantadores de Cana do Médio Tietê. / The planning of activities in agricultural areas, especially in extensive areas as the canaviais, undeniably it is better calculated when there are improved altimetric plain plants. Where it uses the existence of official letters, as the letters of IBGE and the letters of the Cartographic plan of the State of São Paulo are examples, not rare times the planner needs bigger exactness in relation to the equality of vertical distance between curves. The traditional conventional topographical survey, even so presents excellent result, has as inconvenience the spent time and costs. Inside of this context, the present project was developed that had as objective to evidence the exactness of the relief letter gotten for the global positioning system, having as witness laces of contour necessarily leased through the geometric method. Parallel, the present project had also for objective to compare differences of area as surface in plan and inclined, calculated as eletronic and manual methods and the possible influence of the relief in the estimate cane-of-sugar production. The gotten results show that the data collected for a topographical receiver GPS Pró XR Trimble had allowed the generation of altimetric plain plant with 4 equality of vertical distance of 1,0 meter whose precision was compatible with the real relief of field, for what if can suggest the use of the method as sustentation to the planning of agricultural projects. It was also possible to evidence that the methodologies adopted for calculation for area considering plain inclined (X, Y, Z) in the manual and electronic methods, had provided the same results, being that both had presented difference of 0,27% with regard to the respective horizontal... (Complete abstract click electronic access below)
167

Precisão de planta planialtimétrica gerada por modelagem numérica de superfície a partir de coordenadas UTM plano retangulares coletadas em receptor GPS topográfico /

Rodrigues, Ramon Juliano, 1982- January 2006 (has links)
Orientador: Lincoln Gehring Cardoso / Banca: Sérgio Pascoal de Campos / Banca: Rutênio José Latanze / Resumo: O planejamento de atividades em áreas, notadamente em áreas extensas como o caso canaviais, rurais é inegavelmente melhor dimensionado quando se tem em mãos acuradas plantas planialtimetricas. Em que use a existência de cartas oficiais, como são exemplos as cartas do IBGE e as cartas do plano Cartográfico do Estado de São Paulo, não raras vezes o planejador necessitsa de maior acuracidade no que diz respeito à equidistância vertical entre curvas. O tradicional levantamento topográfico convencional embora apresente excelente resultado, tem como inconveniência o tempo dispendido e custos. Dentro desse contexto, foi desenvolvido o presente projeto que teve como objetivo constatar a acurácia de carta de relevo obtida pelo sistema de posicionamento global, tendo como testemunha cordões de contorno precisamente locados através de método geométrico. Paralelamente o presente projeto teve também por objetivo comparar diferenças de área segundo superfície em plano e inclinado calculado segundo métodos eletrônico e manual e a possível influência do relevo na estimativa de produção de cana-deaçúcar. 2 Os resultados obtidos mostram, que os dados coletados por um receptor GPS topográfico Pró XR Trimble permitiram a geração de planta planialtimétrica com equidistância vertical de 1,0 metro cuja precisão foi compatível com o relevo real de campo, pelo que se pode sugerir a utilização do método como sustentação ao planejamento de projetos agrícolas. Foi também possível constatar que as metodologias adotadas para cálculo de área considerando plano inclinado (X Y Z) nos métodos manual e eletrônico, proporcionaram os mesmos resultados sendo que ambos apresentaram diferença de 0,27% com relação à respectiva projeção horizontal o que não explica a diferença entre a produção estimada e real geralmente ao redor de 5,0 %, segundo a Associação dos Plantadores de Cana do Médio Tietê. / Abstract: The planning of activities in agricultural areas, especially in extensive areas as the canaviais, undeniably it is better calculated when there are improved altimetric plain plants. Where it uses the existence of official letters, as the letters of IBGE and the letters of the Cartographic plan of the State of São Paulo are examples, not rare times the planner needs bigger exactness in relation to the equality of vertical distance between curves. The traditional conventional topographical survey, even so presents excellent result, has as inconvenience the spent time and costs. Inside of this context, the present project was developed that had as objective to evidence the exactness of the relief letter gotten for the global positioning system, having as witness laces of contour necessarily leased through the geometric method. Parallel, the present project had also for objective to compare differences of area as surface in plan and inclined, calculated as eletronic and manual methods and the possible influence of the relief in the estimate cane-of-sugar production. The gotten results show that the data collected for a topographical receiver GPS Pró XR Trimble had allowed the generation of altimetric plain plant with 4 equality of vertical distance of 1,0 meter whose precision was compatible with the real relief of field, for what if can suggest the use of the method as sustentation to the planning of agricultural projects. It was also possible to evidence that the methodologies adopted for calculation for area considering plain inclined (X, Y, Z) in the manual and electronic methods, had provided the same results, being that both had presented difference of 0,27% with regard to the respective horizontal... (Complete abstract click electronic access below) / Mestre
168

Avaliação do posicionamento plano-altimétrico com receptor gps em diferentes tipos de uso do solo /

Itame, Otávio Yassuo, 1956- January 2008 (has links)
Orientador: Zacarias Xavier de Barros / Banca: José Milton Arana / Banca: Osmar Delmanto Junior / Banca: Lincoln Gering Cardoso / Banca: Vilmar Antonio Rodrigues / Resumo: Neste trabalho, foram realizados levantamentos topográficos para a avaliação do efeito da cobertura vegetal, na recepção de sinais GPS, para obtenção de posicionamento tri-dimensional, considerando os estudos realizados em diferentes tipos de uso do solo. Vértices foram implantados em diferentes tipos de uso do solo; em área com pastagem, com plantação de seringueiras e com eucaliptos, e as suas posições determinadas com estação total, nivelamento geométrico e com receptores GPS. Na avaliação do posicionamento altimétrico adotou-se como valores de referência os desníveis determinados com o nivelamento geométrico para avaliação dos dados obtidos com receptores GPS. As coordenadas planimétricas obtidas com receptores GPS foram analisadas utilizando-se com valores de referência os dados obtidos com a estação total. No levantamento topográfico com estação total foram adotadas as prescrições estabelecidas nas Normas da Associação Brasileira de Normas Técnicas (ABNT) NBR 13.133, Execução de Levantamentos Topográficos, para poligonais do tipo IVP. Foi realizada a análise de exatidão e de precisão do posicionamento tridimensional, adotando como padrão a NBR 13133 da ABNT para a classe do levantamento executado. Para aplicações do GPS na altimetria há necessidade do conhecimento da ondulação geoidal (N), que neste trabalho, para a sua determinação foram coletados dados com receptor na referência de nível (RN). Os resultados obtidos indicam que cuidados especiais devem ser tomados nos levantamentos com receptores GPS em áreas com cobetura vegetal, pois estas interferem na propagação das ondas eletromagnéticas provenientes dos satélites podendo inviabilizar o posicionamento. / In this work, topographic surveys were carried out in order to evaluate the effect of vegetal cover, on the reception of GPS signals, for 3D positioning, considering studies to be made in different types of land use. Points were set up on different types of land use, in areas containing grass, rubber trees and eucalyptus, which had their positions defined using a total station, geometric leveling and GPS receivers In the evaluation of height positioning it was adopted as reference values the height differences determined by geometric levelling in order to evaluate data obtained through GPS receivers. Planimetric coordinates obtained by using GPS receivers were analysed using as reference values the data obtained using a total station. During the topographic survey using a total station the recommendations set up by the Brazilian Association for Technical Rules (ABNT) NBR 13.133, regarding the execution of topographic surveys, for transverses of type IVP. Accuracy and precision analysis was made on the 3D positioning, also considering ABNT NBR 13.133, for the class of topographic survey which was carried out. In order to apply GPS on height positiong it is necessary to know the geoidal ondulation (N) and, in this work, N was computed based upon data acquired employing receivers at the level reference (RN). The results obtained indicate that special care must be taken during the surveys carried out with the use of GPS receivers on areas with vegetal cover, because it causes interference in the propagation of electromagnetic waves from the satellite which can even make the positioning become unviable. / Doutor
169

Compatibilização de dados, em diferentes referenciais, para atualização cartográfica: estudo de caso na SABESP. / Data transformation for cartographic updating: study of case in SABESP.

Marcos Almir de Oliveira 27 November 2006 (has links)
Um dos propósitos deste trabalho foi apresentar a metodologia envolvida na estimação de parâmetros de transformação entre dois Sistemas Geodésicos, em função da implantação do Sistema de Informações Geográficas no Saneamento (SIGNOS) pela SABESP. Este estudo foi desenvolvido no Município de São Paulo, onde foram calculados parâmetros de transformação entre os Sistemas SAD-69 (South American Datum 1969) e Córrego Alegre. Os parâmetros obtidos neste estudo foram comparados com os parâmetros disponíveis atualmente. Outro estudo, deste trabalho, é a proposta para compatibilização do sistema altimétrico da SABESP. O sistema atual é formado por diversas redes altimétricas (IBGE, SABESP, EMPLASA e IGG) que são divergentes entre si. O objetivo final é verificar as diferenças regionais e estabelecer a unificação do sistema altimétrico da SABESP na Região Metropolitana de São Paulo (RMSP). / One of the purposes of this work was introduce the methodology involved in the estimate of the transformation parameters between two Geodetic Systems, in function of the implantation of the Geographical Information System by SABESP. This work has been developed in São Paulo City, where transformation parameters were calculated between systems SAD-69 (South American Datum 1969) and Córrego Alegre. The estimated parameters at this work had been compared with the available parameters nowadays. Another study, of this work, is the proposal for compatibility of the altimetric system of SABESP. The current system is formed by diverse altimetric nets (IBGE, SABESP, EMPLASA and IGG) that are divergent between themselves. The final objective is to verify the regional differences and to establish the unification of the altimetric system in São Paulo Metropolitan Region (RMSP).
170

Monitoração, por GPS, de deslocamentos em estruturas com carga dinâmica. / Monitoring, by GPS, of displacements in structures with dynamic loads

Régis Fernandes Bueno 20 June 2007 (has links)
A monitoração dinâmica de pontes rodoviárias através da determinação de deslocamentos espaciais é uma das atuais áreas de interesse da geodésia. A tecnologia de posicionamento por satélite é uma das ferramentas disponíveis para este fim e foi avaliada nesta pesquisa. Verifica-se que o GNSS pode contribuir para com o monitoramento dinâmico de estruturas e nos últimos anos se observam aplicações em grandes pontes estaiadas na Ásia, na Europa e na América do Norte. No presente estudo analisou-se a aplicação desta tecnologia em uma estrutura mais rígida, sob vinculo com uma rede de referência única e sob as condições apresentadas pela região brasileira. Foram realizados ensaios em um shaker, na Base de Calibração de Instrumentos Geodésicos da USP e na estrutura do Viaduto Ascendente 19 da rodovia dos Imigrantes, empregando-se a tecnologia GPS e análise modal. A partir de determinações no método relativo cinemático obtiveram-se os deslocamentos tridimensionais e a freqüências do primeiro modo de vibração da estrutura. A metodologia aplicada e os resultados obtidos demonstram a potencialidade do método também para estruturas mais rígidas e sob condições características da região brasileira, que diferem de outras partes do globo no que tange a tecnologia GPS. Ao final é sugerida uma Proposta Básica de Metodologia para a Monitoração de Estrutura com Carga Dinâmica pela Utilização de GNSS. / The dynamic monitoring of road bridges though spatial displacements is one of the geodetic areas of interests. The satellite positioning technologies are one of the disposed tools for this task and were evaluate by present research. One verifies that GNSS can contribute for the dynamic monitoring of structures, and has applied for this task in the last years to large cable stayed bridges on Asia, on Europe and on North America. On the present study, one analyses the use of this technology in a more rigid structure, tied to a unique reference network and under Brazilian region conditions. Were realized essays over a shaker on USP Geodetic Instrumental Calibration Base and over the Imigrantes Roadway Ascending Viaduct 19 employing the GPS technology and modal analysis. By determinations in the kinematics relative method ones obtain the tridimensional displacements and the frequency of first modal shape of the structure. The applied methodology and its obtained results demonstrate the potentiality of this method for more rigid structure too, and under Brazilian region characteristics. At the end is proponed a Methodological Basic Proposal for Dynamic Charged Structure Monitoring thru GNSS Employment.

Page generated in 0.1703 seconds