1

Simulação do sistema de arrefecimento de motores diesel em Matlab-Simulink / Simulation of diesel engine cooling system in Matlab-Simulink

Prado, Wesley Bolognesi 08 March 2006 (has links)
Programa computacional em Matlab-Simulink para simular o comportamento do sistema de arrefecimento de veículos comerciais (vans, ônibus e caminhões) equipados com motores diesel. O programa está embasado em uma modelagem matemática que visa caracterizar o funcionamento dos componentes principais do sistema: motor, radiador, termostato, by-pass e bomba d\'água. Tendo como entrada dados característicos do veículo em estudo, o programa computacional fornece a distribuição de temperatura ao longo do tempo para o líquido de arrefecimento - parâmetro preponderante em uma análise do sistema. Os resultados da simulação permitem aos projetistas prever a atuação do sistema de arrefecimento em diversas condições, o que possibilita a realização de um número menor de testes de pista. Os benefícios de um sistema de arrefecimento projetado adequadamente podem ser notados em relação à economia de combustível, ao aumento de desempenho e à redução do desgaste de determinadas peças do motor e da emissão de poluentes. / A software was developed having Matlab-Simulink as basis and it simulates the behavior of the cooling system in commercial vehicles (vans, bus and trucks) equipped with diesel engines. The program is based on mathematical models to describe the main components of the system: engine, radiator, thermostat, by-pass and water pump. Having as input data the features of the vehicle in studied, the software supplies the cooling fluid temperature distribution during certain time - preponderant parameter in the analysis of the system. The results of the simulation allow the designers to foresee the cooling system performance in several conditions, decreasing the number of track tests. The benefits of an adequate designed cooling system project can be noticed considering fuel economy, performance improvement and decrease of wearing of specific parts in the engine as well as pollutant emissions.
2

Simulação do sistema de arrefecimento de motores diesel em Matlab-Simulink / Simulation of diesel engine cooling system in Matlab-Simulink

Wesley Bolognesi Prado 08 March 2006 (has links)
Programa computacional em Matlab-Simulink para simular o comportamento do sistema de arrefecimento de veículos comerciais (vans, ônibus e caminhões) equipados com motores diesel. O programa está embasado em uma modelagem matemática que visa caracterizar o funcionamento dos componentes principais do sistema: motor, radiador, termostato, by-pass e bomba d\'água. Tendo como entrada dados característicos do veículo em estudo, o programa computacional fornece a distribuição de temperatura ao longo do tempo para o líquido de arrefecimento - parâmetro preponderante em uma análise do sistema. Os resultados da simulação permitem aos projetistas prever a atuação do sistema de arrefecimento em diversas condições, o que possibilita a realização de um número menor de testes de pista. Os benefícios de um sistema de arrefecimento projetado adequadamente podem ser notados em relação à economia de combustível, ao aumento de desempenho e à redução do desgaste de determinadas peças do motor e da emissão de poluentes. / A software was developed having Matlab-Simulink as basis and it simulates the behavior of the cooling system in commercial vehicles (vans, bus and trucks) equipped with diesel engines. The program is based on mathematical models to describe the main components of the system: engine, radiator, thermostat, by-pass and water pump. Having as input data the features of the vehicle in studied, the software supplies the cooling fluid temperature distribution during certain time - preponderant parameter in the analysis of the system. The results of the simulation allow the designers to foresee the cooling system performance in several conditions, decreasing the number of track tests. The benefits of an adequate designed cooling system project can be noticed considering fuel economy, performance improvement and decrease of wearing of specific parts in the engine as well as pollutant emissions.
3

Computational determination of convective heat transfer and pressure drop coefficients of hydrogenerators ventilation system. / Determinação computacional dos coeficientes de transferência de calor por convecção e perda de carga do sistema de ventilação de hidrogeradores.

Altea, Claudinei de Moura 29 July 2016 (has links)
The objective of the present work is to determinate the pressure drop and the heat transfer coefficients, normally applied to analytical calculations of hydrogenerators thermal design, obtained by applying numerical calculation (Computational Fluid Dynamics - CFD) and validated by experimental results and field measurements. The object of study is limited to the most important region of the ventilation system (the cooling air ducts of stator core) to get numerical results of heat transfer and pressure drop coefficients, which are impacted mostly by the entrance of air ducts. The numerical calculations considered three-dimensional, steady-state, incompressible and turbulent flow; and were based on the Finite Volume methodology. The turbulent flow computations were carried out with procedures based on RANS equations by selecting k-omega SST (Shear-Stress Transport) as turbulence model. Grid quality metrics were monitored and the uncertainties due to discretization errors were evaluated by means of a grid independence study and application of an uncertainty estimation procedure based on Richardson extrapolation. The validation of numerical method developed by the present work (specifically to simulate the flow dynamics behavior and to obtain numerically the pressure drop coefficient of the airflow to enter and pass through the Stator Core Air Duct in a hydrogenerator) is performed by comparing the numerical results to experimental data published by Wustmann (2005). The reference experimental data were obtained by a model test. The comparison between numerical and experimental results shows that the difference of pressure drop for Reynolds numbers higher than 5000 is 2% at maximum, while for lower Reynolds numbers, the difference increases significantly and reaches 10%. It is presented that the most reasonable hypothesis for higher discrepancy at lower Reynolds numbers can be assigned to the experiment\'s non-steady-state condition. It is to conclude that the proposed numerical method is validated for the upper region of the analyzed range. Additionally to the model test validation, field measurements were executed in order to confirm numerical results. Measurements of pressure drop in the stator core of a real hydrogenerator were a challenge. Nevertheless, despite all the difficulties and considerable high field measuring uncertainties, trend curves behavior are similar to numerical results. Finally, series of numerical calculation, varying geometrical parameters of the air-duct inlet design and operational data, were done in order to obtain pressure drop coefficients trend curves to be directly applied to analytical calculation routines of whole hydrogenerator ventilation systems. Parallel to it, thermal numerical calculation was executed in the prototype simulation in order to define the convective heat transfer coefficient. / O objetivo do presente trabalho é determinar os coeficientes de perda de carga e transferência de calor, normalmente aplicados nos cálculos analíticos de design térmico de hidrogeradores, obtido pela aplicação de cálculo numérico (Computacional Fluid Dynamics - CFD) e validado por resultados experimentais e medições de campo. O objeto de estudo é limitado à região mais importante do sistema de ventilação (os dutos de ar de arrefecimento do núcleo do estator) para obter resultados numéricos dos coeficientes de transferência de calor e de perda de carga, que são impactados principalmente pela entrada de dutos de ar. Os cálculos numéricos consideraram escoamentos tridimensionais, em regime permanente, incompressíveis e turbulentos; e foram baseados no método dos volumes finitos. Os cálculos de escoamento turbulento foram realizados com procedimentos baseados em equações médias (RANS), utilizando o modelo k-omega SST (Shear-Stress Transport) como modelo de turbulência. Métricas de qualidade de malha foram monitoradas e as incertezas devido à erros de discretização foram avaliadas por meio de um estudo de independência de malha e aplicação de um procedimento de estimativa de incertezas com base na extrapolação de Richardson. A validação do método numérico desenvolvido pelo presente trabalho (especificamente para simular o comportamento dinâmico do escoamento e obter numericamente o coeficiente de perda de carga do escoamento ao entrar no duto de ar e atravessar o núcleo do estator de um hidrogerador) é realizada comparando os resultados numéricos com dados experimentais publicados por Wustmann (2005). Os dados experimentais foram obtidos como referência por um teste de modelo. A comparação entre os resultados numéricos e experimentais mostra que a diferença da perda de carga para números de Reynolds mais elevados do que 5000 é no máximo de 2%, enquanto que para números de Reynolds inferiores, a diferença aumenta significativamente e atinge 10%. A hipótese mais razoável para a maior discrepância para número de Reynolds menores é a possível influência de instabilidades do escoamento no experimento, fazendo com que o regime seja não-permanente. Conclui-se que o método numérico proposto é validado para a região superior do intervalo analisado. Além da validação pelo ensaio de modelo, medições de campo foram executadas, a fim de confirmar os resultados numéricos. As medições de perda de carga no núcleo do estator de um hidrogerador real era um desafio. No entanto, apesar de todas as dificuldades e consideráveis incertezas da medição campo, o comportamento das curvas de tendência ficou alinhado com resultados numéricos. Finalmente, uma série de cálculos numéricos, variando parâmetros geométricos do design da entrada do duto de ar e dados operacionais, foram executados a fim de se obter curvas de tendência para coeficientes de perda de carga (resultados deste trabalho) a serem aplicadas diretamente à rotinas de cálculos analíticos de sistemas completos de ventilação de hidrogeradores. Paralelamente à isso, o cálculo térmico numérico foi executado na simulação do protótipo, a fim de se definir o coeficiente de transferência de calor por convecção.
4

Desenvolvimento de uma metodologia de simulação aplicada ao sistema de arrefecimento veicular. / Simulation metodology development applied to the vehicle cooling system.

Quim, Nelson 17 May 2007 (has links)
Este trabalho visa o estudo de uma metodologia de simulação numérica aplicada ao processo de troca térmica do motor de um veículo de passeio. O processo de troca térmica é essencial para evitar o superaquecimento do motor, que provoca o rompimento do filme de óleo lubrificante dos pistões e, conseqüentemente, o seu travamento. Essa metodologia será útil nos estudos preliminares do sistema de arrefecimento de um veículo na fase inicial de projeto por meio de simulações virtuais, o que possibilitará a redução de protótipos, além de proporcionar um ganho em tempo de resposta. A metodologia utiliza um programa comercial de CFD para a simulação do processo de troca térmica no interior do compartimento do motor do veículo. As simulações foram realizadas com base nos testes físicos em túnel de vento que fazem parte do desenvolvimento e projeto de automóveis em condições de operação que representam situações críticas integrantes da vida operacional. Essas condições operacionais de teste, tais como a velocidade do veículo, as cargas térmicas, a potência dos ventiladores e outros parâmetros foram utilizadas como condições de contorno na validação do modelo do veículo. O processo de validação de modelos é composto por: validações de itens isolados do sistema de arrefecimento, avaliação do efeito da densidade de malha computacional de um modelo completo na vazão de ar nos trocadores de calor e simplificações no modelo para a redução do tempo de processamento. Neste trabalho três modelos distintos de veículos foram utilizados, sendo que dois deles para a validação na comparação com os resultados de túnel vento, enquanto o terceiro modelo foi utilizado para a validação da metodologia através de comparações com os dados obtidos nos testes em pista circular. Os resultados das simulações mostraram variações máximas de 5,5% na temperatura do líquido de arrefecimento na entrada do radiador em relação aos testes. A metodologia de simulação mostrou ser uma poderosa ferramenta de otimização durante a fase de desenvolvimento do projeto e complementando os testes físicos para o sistema de arrefecimento veicular. / The present work is applied to a development of a numerical simulation methodology for a passenger vehicle engine cooling process. The heat exchange process is essential to avoid the engine overheat which may result in the piston oil film separation and consequently its halt. This methodology will be useful for the preliminary studies of the cooling system at the initial phase through the virtual simulations which can reduce the number of prototypes and save proposals\' time response. The methodology uses commercial CFD software for airflow simulation and the thermal process at under hood. The simulations were based on the physical wind tunnel tests that are part of the automotive development, with operational conditions representing critical situations experienced by a vehicle in its operating life. The test conditions, such as vehicle speed, thermal loads, fan power and other parameters were used as the boundary conditions for the model validation. The validation process is based on the following phases: validation of the isolated cooling system components, the effect of mesh density at cooling airflow using a complete vehicle model and model simplification in order to improve the processing time. In this work development, three different models were used; two of them for validation with test tunnel data and the third, was used for methodology validation through the circular road test. The simulation results for tunnel and circular road showed 5.5% of differences for the radiator coolant inlet temperature when compared with physical tests. The methodology of the simulation is a powerful tool for optimization during the development phase and complementing the physical tests for the vehicle cooling systems.
5

Computational determination of convective heat transfer and pressure drop coefficients of hydrogenerators ventilation system. / Determinação computacional dos coeficientes de transferência de calor por convecção e perda de carga do sistema de ventilação de hidrogeradores.

Claudinei de Moura Altea 29 July 2016 (has links)
The objective of the present work is to determinate the pressure drop and the heat transfer coefficients, normally applied to analytical calculations of hydrogenerators thermal design, obtained by applying numerical calculation (Computational Fluid Dynamics - CFD) and validated by experimental results and field measurements. The object of study is limited to the most important region of the ventilation system (the cooling air ducts of stator core) to get numerical results of heat transfer and pressure drop coefficients, which are impacted mostly by the entrance of air ducts. The numerical calculations considered three-dimensional, steady-state, incompressible and turbulent flow; and were based on the Finite Volume methodology. The turbulent flow computations were carried out with procedures based on RANS equations by selecting k-omega SST (Shear-Stress Transport) as turbulence model. Grid quality metrics were monitored and the uncertainties due to discretization errors were evaluated by means of a grid independence study and application of an uncertainty estimation procedure based on Richardson extrapolation. The validation of numerical method developed by the present work (specifically to simulate the flow dynamics behavior and to obtain numerically the pressure drop coefficient of the airflow to enter and pass through the Stator Core Air Duct in a hydrogenerator) is performed by comparing the numerical results to experimental data published by Wustmann (2005). The reference experimental data were obtained by a model test. The comparison between numerical and experimental results shows that the difference of pressure drop for Reynolds numbers higher than 5000 is 2% at maximum, while for lower Reynolds numbers, the difference increases significantly and reaches 10%. It is presented that the most reasonable hypothesis for higher discrepancy at lower Reynolds numbers can be assigned to the experiment\'s non-steady-state condition. It is to conclude that the proposed numerical method is validated for the upper region of the analyzed range. Additionally to the model test validation, field measurements were executed in order to confirm numerical results. Measurements of pressure drop in the stator core of a real hydrogenerator were a challenge. Nevertheless, despite all the difficulties and considerable high field measuring uncertainties, trend curves behavior are similar to numerical results. Finally, series of numerical calculation, varying geometrical parameters of the air-duct inlet design and operational data, were done in order to obtain pressure drop coefficients trend curves to be directly applied to analytical calculation routines of whole hydrogenerator ventilation systems. Parallel to it, thermal numerical calculation was executed in the prototype simulation in order to define the convective heat transfer coefficient. / O objetivo do presente trabalho é determinar os coeficientes de perda de carga e transferência de calor, normalmente aplicados nos cálculos analíticos de design térmico de hidrogeradores, obtido pela aplicação de cálculo numérico (Computacional Fluid Dynamics - CFD) e validado por resultados experimentais e medições de campo. O objeto de estudo é limitado à região mais importante do sistema de ventilação (os dutos de ar de arrefecimento do núcleo do estator) para obter resultados numéricos dos coeficientes de transferência de calor e de perda de carga, que são impactados principalmente pela entrada de dutos de ar. Os cálculos numéricos consideraram escoamentos tridimensionais, em regime permanente, incompressíveis e turbulentos; e foram baseados no método dos volumes finitos. Os cálculos de escoamento turbulento foram realizados com procedimentos baseados em equações médias (RANS), utilizando o modelo k-omega SST (Shear-Stress Transport) como modelo de turbulência. Métricas de qualidade de malha foram monitoradas e as incertezas devido à erros de discretização foram avaliadas por meio de um estudo de independência de malha e aplicação de um procedimento de estimativa de incertezas com base na extrapolação de Richardson. A validação do método numérico desenvolvido pelo presente trabalho (especificamente para simular o comportamento dinâmico do escoamento e obter numericamente o coeficiente de perda de carga do escoamento ao entrar no duto de ar e atravessar o núcleo do estator de um hidrogerador) é realizada comparando os resultados numéricos com dados experimentais publicados por Wustmann (2005). Os dados experimentais foram obtidos como referência por um teste de modelo. A comparação entre os resultados numéricos e experimentais mostra que a diferença da perda de carga para números de Reynolds mais elevados do que 5000 é no máximo de 2%, enquanto que para números de Reynolds inferiores, a diferença aumenta significativamente e atinge 10%. A hipótese mais razoável para a maior discrepância para número de Reynolds menores é a possível influência de instabilidades do escoamento no experimento, fazendo com que o regime seja não-permanente. Conclui-se que o método numérico proposto é validado para a região superior do intervalo analisado. Além da validação pelo ensaio de modelo, medições de campo foram executadas, a fim de confirmar os resultados numéricos. As medições de perda de carga no núcleo do estator de um hidrogerador real era um desafio. No entanto, apesar de todas as dificuldades e consideráveis incertezas da medição campo, o comportamento das curvas de tendência ficou alinhado com resultados numéricos. Finalmente, uma série de cálculos numéricos, variando parâmetros geométricos do design da entrada do duto de ar e dados operacionais, foram executados a fim de se obter curvas de tendência para coeficientes de perda de carga (resultados deste trabalho) a serem aplicadas diretamente à rotinas de cálculos analíticos de sistemas completos de ventilação de hidrogeradores. Paralelamente à isso, o cálculo térmico numérico foi executado na simulação do protótipo, a fim de se definir o coeficiente de transferência de calor por convecção.
6

Estudo e modelagem da arquitetura modular de uma usina solar fotovoltaica arrefecida com protótipo de verificação. / Study and modeling of modular architecture of a solar photovoltaic power plant cooled with verification prototype.

Silva, Vinícius Oliveira da 30 November 2015 (has links)
O objetivo deste trabalho é modelar a arquitetura de uma usina solar fotovoltaica arrefecida intitulada UFVa, utilizando um protótipo de verificação. A metodologia se baseia na medição, verificação e análise dos dados de temperatura e produção de energia elétrica dos strings de teste (arrefecido) e comparação (não arrefecido), estudo do comportamento da alimentação de água do sistema de arrefecimento e o impacto das condições climáticas na operação do protótipo de UFVa. Por meio das análises dos dados constatou-se que, para o período entre as 09h00min e as 17h30min, os módulos PV do string de teste sempre operam com temperaturas inferiores aos módulos PV do string de comparação. Durante o período de testes, no qual a temperatura dos módulos PV do string de comparação operou acima de 55,0°C, as temperaturas médias e máximas registradas nos módulos PV do string de teste foram inferiores a 37,0 °C, operando sempre abaixo da temperatura nominal de operação da célula (NOCT). A produção de energia elétrica no string de teste superou a do string de comparação em 3,0kWh/dia. Portanto, o sistema de arrefecimento reduz a temperatura de operação dos módulos PV, principalmente no período de máxima geração elétrica, que corresponde ao período das 11h00min às 15h00min, proporcionando ganhos médios de rendimento de 5,9% na produção de energia, 10,3% na potência e 5,4% no FC. / In this work we use a verification prototype to model the architecture of a solar photovoltaic power plant equipped with a cooling system. The power plant we model is called UFVa. The methodology is based on the measurement, verification, and data analysis of temperature, electricity generation, test strings (cooled) and comparison strings (not cooled), along with a study of the water feeding behavior of the cooling system, and the impact of climatic conditions in the UFVa prototype operation. By analyzing the data we observed that, for the period between 09:00am and 5:30pm, the PV modules of the test string operate at temperatures below those of the PV modules of the comparison string. During the tests, in which the temperature of the PV modules of the comparison string operated above 55.0°C, the average and the maximum temperatures recorded in the PV modules of the testing string lied below 37.0°C, operating below the NOCT. Regarding the generation of electricity, the test string generated 3.0 kWh/day more than the comparison string. Hence, the cooling system decreases the operating temperature of the PV modules, particularly during the maximum power generation period which is from 11am to 3pm. This leads to efficiency average gains of up to 5.9% in the generation of electricity, 10.3% in the power, and 5.3% in the PR and PF.
7

Desenvolvimento de uma metodologia de simulação aplicada ao sistema de arrefecimento veicular. / Simulation metodology development applied to the vehicle cooling system.

Nelson Quim 17 May 2007 (has links)
Este trabalho visa o estudo de uma metodologia de simulação numérica aplicada ao processo de troca térmica do motor de um veículo de passeio. O processo de troca térmica é essencial para evitar o superaquecimento do motor, que provoca o rompimento do filme de óleo lubrificante dos pistões e, conseqüentemente, o seu travamento. Essa metodologia será útil nos estudos preliminares do sistema de arrefecimento de um veículo na fase inicial de projeto por meio de simulações virtuais, o que possibilitará a redução de protótipos, além de proporcionar um ganho em tempo de resposta. A metodologia utiliza um programa comercial de CFD para a simulação do processo de troca térmica no interior do compartimento do motor do veículo. As simulações foram realizadas com base nos testes físicos em túnel de vento que fazem parte do desenvolvimento e projeto de automóveis em condições de operação que representam situações críticas integrantes da vida operacional. Essas condições operacionais de teste, tais como a velocidade do veículo, as cargas térmicas, a potência dos ventiladores e outros parâmetros foram utilizadas como condições de contorno na validação do modelo do veículo. O processo de validação de modelos é composto por: validações de itens isolados do sistema de arrefecimento, avaliação do efeito da densidade de malha computacional de um modelo completo na vazão de ar nos trocadores de calor e simplificações no modelo para a redução do tempo de processamento. Neste trabalho três modelos distintos de veículos foram utilizados, sendo que dois deles para a validação na comparação com os resultados de túnel vento, enquanto o terceiro modelo foi utilizado para a validação da metodologia através de comparações com os dados obtidos nos testes em pista circular. Os resultados das simulações mostraram variações máximas de 5,5% na temperatura do líquido de arrefecimento na entrada do radiador em relação aos testes. A metodologia de simulação mostrou ser uma poderosa ferramenta de otimização durante a fase de desenvolvimento do projeto e complementando os testes físicos para o sistema de arrefecimento veicular. / The present work is applied to a development of a numerical simulation methodology for a passenger vehicle engine cooling process. The heat exchange process is essential to avoid the engine overheat which may result in the piston oil film separation and consequently its halt. This methodology will be useful for the preliminary studies of the cooling system at the initial phase through the virtual simulations which can reduce the number of prototypes and save proposals\' time response. The methodology uses commercial CFD software for airflow simulation and the thermal process at under hood. The simulations were based on the physical wind tunnel tests that are part of the automotive development, with operational conditions representing critical situations experienced by a vehicle in its operating life. The test conditions, such as vehicle speed, thermal loads, fan power and other parameters were used as the boundary conditions for the model validation. The validation process is based on the following phases: validation of the isolated cooling system components, the effect of mesh density at cooling airflow using a complete vehicle model and model simplification in order to improve the processing time. In this work development, three different models were used; two of them for validation with test tunnel data and the third, was used for methodology validation through the circular road test. The simulation results for tunnel and circular road showed 5.5% of differences for the radiator coolant inlet temperature when compared with physical tests. The methodology of the simulation is a powerful tool for optimization during the development phase and complementing the physical tests for the vehicle cooling systems.
8

Estudo e modelagem da arquitetura modular de uma usina solar fotovoltaica arrefecida com protótipo de verificação. / Study and modeling of modular architecture of a solar photovoltaic power plant cooled with verification prototype.

Vinícius Oliveira da Silva 30 November 2015 (has links)
O objetivo deste trabalho é modelar a arquitetura de uma usina solar fotovoltaica arrefecida intitulada UFVa, utilizando um protótipo de verificação. A metodologia se baseia na medição, verificação e análise dos dados de temperatura e produção de energia elétrica dos strings de teste (arrefecido) e comparação (não arrefecido), estudo do comportamento da alimentação de água do sistema de arrefecimento e o impacto das condições climáticas na operação do protótipo de UFVa. Por meio das análises dos dados constatou-se que, para o período entre as 09h00min e as 17h30min, os módulos PV do string de teste sempre operam com temperaturas inferiores aos módulos PV do string de comparação. Durante o período de testes, no qual a temperatura dos módulos PV do string de comparação operou acima de 55,0°C, as temperaturas médias e máximas registradas nos módulos PV do string de teste foram inferiores a 37,0 °C, operando sempre abaixo da temperatura nominal de operação da célula (NOCT). A produção de energia elétrica no string de teste superou a do string de comparação em 3,0kWh/dia. Portanto, o sistema de arrefecimento reduz a temperatura de operação dos módulos PV, principalmente no período de máxima geração elétrica, que corresponde ao período das 11h00min às 15h00min, proporcionando ganhos médios de rendimento de 5,9% na produção de energia, 10,3% na potência e 5,4% no FC. / In this work we use a verification prototype to model the architecture of a solar photovoltaic power plant equipped with a cooling system. The power plant we model is called UFVa. The methodology is based on the measurement, verification, and data analysis of temperature, electricity generation, test strings (cooled) and comparison strings (not cooled), along with a study of the water feeding behavior of the cooling system, and the impact of climatic conditions in the UFVa prototype operation. By analyzing the data we observed that, for the period between 09:00am and 5:30pm, the PV modules of the test string operate at temperatures below those of the PV modules of the comparison string. During the tests, in which the temperature of the PV modules of the comparison string operated above 55.0°C, the average and the maximum temperatures recorded in the PV modules of the testing string lied below 37.0°C, operating below the NOCT. Regarding the generation of electricity, the test string generated 3.0 kWh/day more than the comparison string. Hence, the cooling system decreases the operating temperature of the PV modules, particularly during the maximum power generation period which is from 11am to 3pm. This leads to efficiency average gains of up to 5.9% in the generation of electricity, 10.3% in the power, and 5.3% in the PR and PF.