Spelling suggestions: "subject:"sludge system"" "subject:"kludge system""
1 |
Avaliação do tratamento combinado de lixiviado de aterro sanitário e esgoto sanitário em sistema de lodos ativados / Evaluation of the combined treatment of landfill leachate and domestic sewage in activated sludge systemAlbuquerque, Edilincon Martins de 05 June 2012 (has links)
Um dos principais resíduos gerados nos aterros é o lixiviado, que possui elevada concentração de matéria orgânica biodegradável e refratária e de matéria inorgânica, como nitrogênio amoniacal e metais pesados. O tratamento combinado de lixiviado com esgoto sanitário tem sido utilizado em algumas estações de tratamento de esgoto (ETE) brasileiras. No entanto, o processo ainda sofre vários questionamentos e incertezas, especialmente sobre os efeitos da adição do lixiviado sobre o sistema de tratamento. Nesse contexto, o presente trabalho visou avaliar a eficiência do tratamento combinado de lixiviado/esgoto em sistema de lodos ativados, em diferentes condições. Na primeira etapa desta pesquisa, foram realizados experimentos de tratabilidade em escala de bancada (regime de batelada) utilizando as proporções volumétricas de 0% (controle), 0,2%, 2% e 5% de lixiviado em diferentes condições experimentais. Dentre eles, o Experimento 2 (lixiviado pré-tratado por alcalinização e air stripping) se mostrou mais viável tecnicamente, alcançando eficiências de remoção da DBO, da DQO e do COD acima de 97, 82, 60%, respectivamente, até a proporção de 2% de lixiviado pré-tratado. Na segunda etapa da pesquisa, foi avaliada a tratabilidade utilizando reatores em escala piloto (regime contínuo) tratando esgoto sanitário com 2% (P1) e 0% (P2-controle) de lixiviado pré-tratado, com relação microrganismo-alimento de 0,22 kgDBO/kgSSV.dia, tempo de detenção hidráulica de 24 horas e idade do lodo de 20 dias. Os resultados indicaram viabilidade do tratamento nas condições estudadas com 2% de lixiviado pré-tratado, cujas eficiências médias de remoção da DBO, da DQO, do COD foram de 93, 84 e 60%, respectivamente. Esta pesquisa foi desenvolvida com apoio financeiro (Processo N° 2010/51955-2) da Fundação de Amparo à Pesquisa de São Paulo (FAPESP). / The leachate is one of the main wastes generated in landfills, it has a high concentration of biodegradable and refractory organic matter and inorganic matter, such as ammonia and heavy metals. The combined treatment of leachate with sewage has been used in various sewage treatment plants in Brazil. However, there are still many questions and uncertainties about the process, especially the effects of adding leachate on the treatment system. In this context, this study aimed at evaluating the efficiency of combined treatment of leachate/sewage in activated sludge under different conditions. In the first stage of this research, treatability experiments were carried out in a bench scale (SBR) using the volumetric proportions of 0% (control), 0.2%, 2% and 5% leachate under different experimental conditions. The Experiment 2 (leachate pretreated by alkalinization and air stripping) was more technically feasible, achieving efficiencies of removal of BOD, COD and DOC above 97, 82, 60%, respectively, until the proportion of 2% pre-treated leachate. In the second stage of the research was evaluated the treatability using pilot-scale reactors (continuous flow) for sewage treatment with 2% (P1) and 0% (P2-control) leachate pretreated. The operational parameters adopted were food-microorganism rate of 0.22 kgDBO/ kgSSV.d, hydraulic retention time of 24 hours and the sludge retention time of 20 days. The results indicated the viability of the combined treatment with 2% leached pretreated, whose average efficiency of removing BOD, COD, DOC were 93, 84 and 60% respectively. This research was developed with financial support (case No. 2010/2-51955) of Fundação de Amparo à Pesquisa de São Paulo (FAPESP).
|
2 |
Avaliação do tratamento combinado de lixiviado de aterro sanitário e esgoto sanitário em sistema de lodos ativados / Evaluation of the combined treatment of landfill leachate and domestic sewage in activated sludge systemEdilincon Martins de Albuquerque 05 June 2012 (has links)
Um dos principais resíduos gerados nos aterros é o lixiviado, que possui elevada concentração de matéria orgânica biodegradável e refratária e de matéria inorgânica, como nitrogênio amoniacal e metais pesados. O tratamento combinado de lixiviado com esgoto sanitário tem sido utilizado em algumas estações de tratamento de esgoto (ETE) brasileiras. No entanto, o processo ainda sofre vários questionamentos e incertezas, especialmente sobre os efeitos da adição do lixiviado sobre o sistema de tratamento. Nesse contexto, o presente trabalho visou avaliar a eficiência do tratamento combinado de lixiviado/esgoto em sistema de lodos ativados, em diferentes condições. Na primeira etapa desta pesquisa, foram realizados experimentos de tratabilidade em escala de bancada (regime de batelada) utilizando as proporções volumétricas de 0% (controle), 0,2%, 2% e 5% de lixiviado em diferentes condições experimentais. Dentre eles, o Experimento 2 (lixiviado pré-tratado por alcalinização e air stripping) se mostrou mais viável tecnicamente, alcançando eficiências de remoção da DBO, da DQO e do COD acima de 97, 82, 60%, respectivamente, até a proporção de 2% de lixiviado pré-tratado. Na segunda etapa da pesquisa, foi avaliada a tratabilidade utilizando reatores em escala piloto (regime contínuo) tratando esgoto sanitário com 2% (P1) e 0% (P2-controle) de lixiviado pré-tratado, com relação microrganismo-alimento de 0,22 kgDBO/kgSSV.dia, tempo de detenção hidráulica de 24 horas e idade do lodo de 20 dias. Os resultados indicaram viabilidade do tratamento nas condições estudadas com 2% de lixiviado pré-tratado, cujas eficiências médias de remoção da DBO, da DQO, do COD foram de 93, 84 e 60%, respectivamente. Esta pesquisa foi desenvolvida com apoio financeiro (Processo N° 2010/51955-2) da Fundação de Amparo à Pesquisa de São Paulo (FAPESP). / The leachate is one of the main wastes generated in landfills, it has a high concentration of biodegradable and refractory organic matter and inorganic matter, such as ammonia and heavy metals. The combined treatment of leachate with sewage has been used in various sewage treatment plants in Brazil. However, there are still many questions and uncertainties about the process, especially the effects of adding leachate on the treatment system. In this context, this study aimed at evaluating the efficiency of combined treatment of leachate/sewage in activated sludge under different conditions. In the first stage of this research, treatability experiments were carried out in a bench scale (SBR) using the volumetric proportions of 0% (control), 0.2%, 2% and 5% leachate under different experimental conditions. The Experiment 2 (leachate pretreated by alkalinization and air stripping) was more technically feasible, achieving efficiencies of removal of BOD, COD and DOC above 97, 82, 60%, respectively, until the proportion of 2% pre-treated leachate. In the second stage of the research was evaluated the treatability using pilot-scale reactors (continuous flow) for sewage treatment with 2% (P1) and 0% (P2-control) leachate pretreated. The operational parameters adopted were food-microorganism rate of 0.22 kgDBO/ kgSSV.d, hydraulic retention time of 24 hours and the sludge retention time of 20 days. The results indicated the viability of the combined treatment with 2% leached pretreated, whose average efficiency of removing BOD, COD, DOC were 93, 84 and 60% respectively. This research was developed with financial support (case No. 2010/2-51955) of Fundação de Amparo à Pesquisa de São Paulo (FAPESP).
|
3 |
Sistema cíclico de lodo ativado empregado para remoção biológica de nutrientes de esgoto sanitário. / Cyclic activated sludge system used for biological nutrient removal from sewage.Martins Neto, Henrique 25 September 2014 (has links)
Tendo em vista a crescente problemática quanto à eutrofização de corpos dágua em países em desenvolvimento, devido ao lançamento de esgoto mesmo que tratado em nível secundário, o processo de lodo ativado vem sendo estudo e aprimorado para efetuar a remoção conjunta de matéria orgânica, nitrogênio e o fósforo, nutrientes limitantes para ocorrência da eutrofização. Neste contexto, o presente trabalho pretende contribuir com informações quanto à remoção biológica de nutrientes de esgoto sanitário através de estudo em escala piloto em um sistema cíclico de lodo ativado. Este sistema, operado em regime de bateladas sequenciais, difere da configuração habitual, pois possui três compartimentos internos, zonas 1, 2 e 3 que apresentam condições anaeróbias/anóxicas, anóxicas e aeróbias respectivamente, além do retorno de lodo da zona 3 para zona 1 durante o período de reação, sob vazão de 20% da vazão afluente a unidade. Cada batelada possui duração de 4 horas, distribuídas em 4 etapas de 1h cada, sendo elas o enchimento com aeração, reação, sedimentação e descarga. Com essas características o sistema cíclico de lodo ativado do presente estudo, demonstrou no tratamento de esgoto sanitário, elevada eficiência na remoção de matéria orgânica, sempre acima de 90%, além da boa eficiência de remoção nitrogênio através do processo de nitrificação e desnitrificação, cuja concentração média de amônia e nitrato no efluente final foram respectivamente de 2,8 e 11,4 mgN.L-1 para idade de lodo de 25 dias e quando operado com 12 dias de idade, o efluente apresentou concentração de 6,6 e 12,4 mgN.L-1. Também foram determinadas via respirometria as taxas máximas de crescimento (n,max) para bactérias nitrificantes e nitratantes, os valores obtidos foram respectivos, de 0,45 d-1 e 0,37 d-1 para idade de lodo de 12 dias, resultados próximos a literatura. A remoção biológica de fósforo foi obtida com melhor resultado na segunda etapa, superando 95% de eficiência, produzindo efluente final com teor de fósforo total inferior a 0,5 mgP.L-1. / Given the growing problem regarding the eutrophication of water bodies in developing countries, due to discharge of sewage treated even at the secondary level, the activated sludge process has been enhanced to study and perform the joint removal of organic matter, nitrogen and phosphorus, the limiting nutrient for the occurrence of eutrophication. In this context, this work aims to contribute information for biological nutrient removal from wastewater by pilot scale study in a cyclic activated sludge system. This system operated in sequential batch system differs from typical configuration because it has three internal compartments, zones 1, 2 and 3 show that anaerobic / anoxic, aerobic and anoxic respectively, beyond the conditions of return sludge from zone 3 to zone 1 during the reaction, flow rate under 20% of the influent flow unit. Each batch has a duration of 4 hours, distributed into 4 stages each 1H, they aeration and filling, reaction, settling and discharge. With these characteristics the cyclic activated sludge system of the present study showed for the treatment of sewage, high efficiency in the removal of organic matter, always above 90%, besides the good efficiency of nitrogen removal by nitrification and denitrification, which average concentration of ammonia and nitrate in the final effluent were respectively 2.8 and 11.4 mgN.L-1 for sludge age of 25 days, when operated at 12 days of age, the effluent showed a concentration of 6.6 to 12 4 mgN.L-1. Were also determined via respirometry maximum growth rates (n, max) for nitrifying bacteria and nitratantes, the respective value obtained were, 0.45 d-1 and 0.37 d-1 for sludge age of 12 days, results Nearby literature. Biological phosphorus removal was obtained with better results in the second stage, surpassing 95% efficiency, producing the final content of the effluent below 0.5 mgP.L-1 total phosphorus.
|
4 |
Sistema cíclico de lodo ativado empregado para remoção biológica de nutrientes de esgoto sanitário. / Cyclic activated sludge system used for biological nutrient removal from sewage.Henrique Martins Neto 25 September 2014 (has links)
Tendo em vista a crescente problemática quanto à eutrofização de corpos dágua em países em desenvolvimento, devido ao lançamento de esgoto mesmo que tratado em nível secundário, o processo de lodo ativado vem sendo estudo e aprimorado para efetuar a remoção conjunta de matéria orgânica, nitrogênio e o fósforo, nutrientes limitantes para ocorrência da eutrofização. Neste contexto, o presente trabalho pretende contribuir com informações quanto à remoção biológica de nutrientes de esgoto sanitário através de estudo em escala piloto em um sistema cíclico de lodo ativado. Este sistema, operado em regime de bateladas sequenciais, difere da configuração habitual, pois possui três compartimentos internos, zonas 1, 2 e 3 que apresentam condições anaeróbias/anóxicas, anóxicas e aeróbias respectivamente, além do retorno de lodo da zona 3 para zona 1 durante o período de reação, sob vazão de 20% da vazão afluente a unidade. Cada batelada possui duração de 4 horas, distribuídas em 4 etapas de 1h cada, sendo elas o enchimento com aeração, reação, sedimentação e descarga. Com essas características o sistema cíclico de lodo ativado do presente estudo, demonstrou no tratamento de esgoto sanitário, elevada eficiência na remoção de matéria orgânica, sempre acima de 90%, além da boa eficiência de remoção nitrogênio através do processo de nitrificação e desnitrificação, cuja concentração média de amônia e nitrato no efluente final foram respectivamente de 2,8 e 11,4 mgN.L-1 para idade de lodo de 25 dias e quando operado com 12 dias de idade, o efluente apresentou concentração de 6,6 e 12,4 mgN.L-1. Também foram determinadas via respirometria as taxas máximas de crescimento (n,max) para bactérias nitrificantes e nitratantes, os valores obtidos foram respectivos, de 0,45 d-1 e 0,37 d-1 para idade de lodo de 12 dias, resultados próximos a literatura. A remoção biológica de fósforo foi obtida com melhor resultado na segunda etapa, superando 95% de eficiência, produzindo efluente final com teor de fósforo total inferior a 0,5 mgP.L-1. / Given the growing problem regarding the eutrophication of water bodies in developing countries, due to discharge of sewage treated even at the secondary level, the activated sludge process has been enhanced to study and perform the joint removal of organic matter, nitrogen and phosphorus, the limiting nutrient for the occurrence of eutrophication. In this context, this work aims to contribute information for biological nutrient removal from wastewater by pilot scale study in a cyclic activated sludge system. This system operated in sequential batch system differs from typical configuration because it has three internal compartments, zones 1, 2 and 3 show that anaerobic / anoxic, aerobic and anoxic respectively, beyond the conditions of return sludge from zone 3 to zone 1 during the reaction, flow rate under 20% of the influent flow unit. Each batch has a duration of 4 hours, distributed into 4 stages each 1H, they aeration and filling, reaction, settling and discharge. With these characteristics the cyclic activated sludge system of the present study showed for the treatment of sewage, high efficiency in the removal of organic matter, always above 90%, besides the good efficiency of nitrogen removal by nitrification and denitrification, which average concentration of ammonia and nitrate in the final effluent were respectively 2.8 and 11.4 mgN.L-1 for sludge age of 25 days, when operated at 12 days of age, the effluent showed a concentration of 6.6 to 12 4 mgN.L-1. Were also determined via respirometry maximum growth rates (n, max) for nitrifying bacteria and nitratantes, the respective value obtained were, 0.45 d-1 and 0.37 d-1 for sludge age of 12 days, results Nearby literature. Biological phosphorus removal was obtained with better results in the second stage, surpassing 95% efficiency, producing the final content of the effluent below 0.5 mgP.L-1 total phosphorus.
|
5 |
Tratamento de lixiviados de aterros sanitários em sistema de reatores anaeróbio e aeróbio operados em batelada seqüencial / Landfill leachate treatment in sequence anaerobic and aerobic batch reactors systemsContrera, Ronan Cleber 06 June 2008 (has links)
Este trabalho avaliou a tratabilidade dos lixiviados do aterro sanitário de São Carlos-SP, utilizando-se reatores biológicos. O experimento foi conduzido à temperatura ambiente, em uma unidade piloto construída no aterro sanitário de São Carlos-SP. Inicialmente foram testados e comparados dois tipos de reatores anaeróbios, cada um com volume total de 1.200 L e ambos providos de agitação mecânica, diferenciando-se pelo tipo de imobilização da biomassa, sendo o primeiro com biomassa auto-imobilizada (ASBR) e o segundo com biomassa imobilizada em espuma de poliuretano (ASBBR). Um filtro biológico anaeróbio contínuo de fluxo ascendente de aproximadamente 120 L também foi avaliado. Além do pré-tratamento anaeróbio, foi avaliado também o pós-tratamento, que consistiu em um sistema de lodos ativados em batelada seqüencial de aproximadamente 180 L. O ASBR, inoculado com lodo granular de reator UASB, apresentou-se ineficiente, com problemas de desagregação e sedimentação da biomassa. O ASBBR, inoculado com lodo proveniente do fundo de uma lagoa de lixiviados, ao final de sua adaptação, apresentou eficiências superiores a 70%, em termos de remoção de DQO, utilizando-se lixiviado sem diluição, com DQO afluente da ordem de 11.000 mg/L, relação AVT/DQO aproximadamente igual a 0,6 e tempo de reação igual a 7 dias. Verificou-se que a biodegradabilidade anaeróbia dos lixiviados está diretamente relacionada à relação AVT/DQO, e que para relações AVT/DQO Total inferiores a 0,25, a biodegradabilidade é baixa, para relações entre 0,25 e 0,40 é média, e acima de 0,40 pode ser considerada elevada. Observou-se também que concentrações de N-amoniacal, da ordem de até 4.500 mg/L, não impedem o tratamento anaeróbio, desde que a biomassa esteja devidamente adaptada. Aos perfis temporais de concentração, realizados no ASBBR, foi ajustado um modelo de primeira ordem para consumo de substrato, na forma de DQO Total, obtendo valores de K1 variando entre 3,18 x \'10 POT.-5\' e 5,82 x \'10 POT.-5\' /(d.mgSTV/L). O pós-tratamento dos efluentes do ASBBR foi avaliado em um sistema de lodos ativados em batelada seqüencial, que obteve eficiência máxima da ordem de 30% em termos de remoção de DQO, com DQO afluente da ordem de 5.000 mg/L. Quanto ao filtro biológico anaeróbio de fluxo ascendente, obteve-se eficiências superiores a 70%, ao ser alimentado com uma mistura de lixiviado recalcitrante e etanol acidificado, com DQO afluente da ordem de 20.000 mg/L. / This work evaluated the tractability of landfill leachate from São Carlos-SP, utilizing biological reactors. The experiment was conducted at environmental temperature, in a pilot scale unity constructed into the São Carlos-SP landfill area. Initially, it was compared and tested two kinds of anaerobic reactors, each one with 1.200 L of total volume and both provided of mechanical agitation, differing by the kind of biomass immobilization, having the first (ASBR), self-immobilized biomass, and the second (ASBBR), immobilized biomass in polyurethane foam cubes. An approximately 120 L volume continuous up flow anaerobic biofilter was also evaluated. Additionally to the anaerobic treatment, it was also evaluated the post-treatment of landfill leachate in a sequence batch activated sludge system of 180 L. The ASBR, inoculated with a granular UASB sludge from a poultry wastewater treatment, was inefficient and presented sludge segregation and sedimentation problems. The ASBBR, inoculated using the sludge from the bottom of a landfill leachate reservoir, at the final of acclimation, presented efficiency over 70%, in terms of COD removal, utilizing landfill leachate without water dilution, with an inlet COD at the range of 11,000 mg/L, a TVA/COD ratio of approximately 0.6 and reaction time equal to 7 days. It was realized that the landfill leachate anaerobic biodegradability has a directly relationship to the TVA/COD ratio, and for TVA/COD Total ratio lower than 0.25, the biodegradability is low, for ratios between 0.25 and 0.40 is medium, and up to 0.40 may be considered high. It was also observed that \'NH IND.4\' POT.+\' concentrations at the range of 4,500 mg N/L has no significant interference in the anaerobic treatment, since the biomass has properly acclimated. At the temporal profiles of concentration performed in the ASBBR, it was adjusted a first order model for the substrate consumption, in terms of COD Total, obtaining K1 values ranging between 3.18 x \'10 POT.-5\' and 5.82 x \'10 POT.-5\' /(d.mgSTV/L). The post-treatment of the ASBBR effluents was evaluated in a sequence batch activated sludge system, which has obtained maximum efficiencies at the range of 30% in terms of COD removal, with an inlet COD at the range of 5,000 mg/L. As regards of the continuous up flow anaerobic biofilter, it has obtained efficiencies superiors to 70% when fed by a mixing of recovery landfill leachate and acidified ethanol, with an inlet COD at the range of 20,000 mg/L.
|
6 |
IDENTIFICAÇÃO DE UM SISTEMA DE LODO ATIVADO DE PEQUENA ESCALA DESENVOLVIDO EM LABORATÓRIO / IDENTIFICATION OF A ACTIVATED SLUDGE SYSTEM ON SCALE SMALL DEVELOPED IN THE LABORATORYLima, Freud Sebastian Bach Carvalho 29 July 2011 (has links)
Made available in DSpace on 2016-08-17T14:53:17Z (GMT). No. of bitstreams: 1
Freud Sebastian Bach Carvalho Lima.pdf: 1668786 bytes, checksum: 953b0905b2e9bcd1cefb5702b8c6b362 (MD5)
Previous issue date: 2011-07-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In activated sludge systems, the dissolved oxygen is used by microorganisms to decompose organic matter and treatment of wastewater. In these systems the dynamics of dissolved oxygen has been seen as the main source of information to obtain online information about the treatment process. Thus, the development of an appropriate model for the dynamics of dissolved oxygen and estimation of the parameters of this model can improve the quality of the estimates of process parameters and, consequently, the measurement system. In this study, a model of the bench-scale reactor is developed considering the dynamics associated with the operation of the aeration system and the dissolved oxygen sensor. The aeration system consists of air pumps with two operating states: on or off, and dissolved oxygen measurement is made by electrochemical cell based on Clark. Approach was used identification systems in continuous time and state variable filters with the least squares estimator for estimating the parameters of the model developed. Simulations and experimental results, using a bench scale reactor developed in the laboratory, are presented to illustrate the proposed model. / Em sistemas de lodo ativado, o oxigênio dissolvido é utilizado por microorganismos para decomposição de matéria orgânica e tratamento de água residuárias. Nestes sistemas, a dinâmica de oxigênio dissolvido tem sido vista como a principal fonte de informação para obtenção de informações online sobre o processo de tratamento. Com isso, o desenvolvimento de um modelo apropriado para dinâmica do oxigênio dissolvido e a estimação dos parâmetros deste modelo, pode melhorar a qualidade das estimativas dos parâmetros do processo e, consequentemente, do sistema de medição. No presente trabalho, um modelo do reator em escala de bancada é desenvolvido considerando as dinâmicas relacionadas com a operação do sistema de aeração e com o sensor de oxigênio dissolvido. O sistema de aeração é composto por bombas de ar com dois estados de operação: ligada ou desligada, e a medição de oxigênio dissolvido é realizada por sensor eletroquímico baseado em célula de Clark. Usa-se abordagem de identificação de sistemas em tempo contínuo e filtros de variável de estado junto com o estimador dos mínimos quadrados para estimação dos parâmetros do modelo desenvolvido. Simulações e resultados experimentais, utilizando um reator em escala de bancada desenvolvido no laboratório, são apresentados para ilustrar o modelo proposto.
|
7 |
Tratamento de lixiviados de aterros sanitários em sistema de reatores anaeróbio e aeróbio operados em batelada seqüencial / Landfill leachate treatment in sequence anaerobic and aerobic batch reactors systemsRonan Cleber Contrera 06 June 2008 (has links)
Este trabalho avaliou a tratabilidade dos lixiviados do aterro sanitário de São Carlos-SP, utilizando-se reatores biológicos. O experimento foi conduzido à temperatura ambiente, em uma unidade piloto construída no aterro sanitário de São Carlos-SP. Inicialmente foram testados e comparados dois tipos de reatores anaeróbios, cada um com volume total de 1.200 L e ambos providos de agitação mecânica, diferenciando-se pelo tipo de imobilização da biomassa, sendo o primeiro com biomassa auto-imobilizada (ASBR) e o segundo com biomassa imobilizada em espuma de poliuretano (ASBBR). Um filtro biológico anaeróbio contínuo de fluxo ascendente de aproximadamente 120 L também foi avaliado. Além do pré-tratamento anaeróbio, foi avaliado também o pós-tratamento, que consistiu em um sistema de lodos ativados em batelada seqüencial de aproximadamente 180 L. O ASBR, inoculado com lodo granular de reator UASB, apresentou-se ineficiente, com problemas de desagregação e sedimentação da biomassa. O ASBBR, inoculado com lodo proveniente do fundo de uma lagoa de lixiviados, ao final de sua adaptação, apresentou eficiências superiores a 70%, em termos de remoção de DQO, utilizando-se lixiviado sem diluição, com DQO afluente da ordem de 11.000 mg/L, relação AVT/DQO aproximadamente igual a 0,6 e tempo de reação igual a 7 dias. Verificou-se que a biodegradabilidade anaeróbia dos lixiviados está diretamente relacionada à relação AVT/DQO, e que para relações AVT/DQO Total inferiores a 0,25, a biodegradabilidade é baixa, para relações entre 0,25 e 0,40 é média, e acima de 0,40 pode ser considerada elevada. Observou-se também que concentrações de N-amoniacal, da ordem de até 4.500 mg/L, não impedem o tratamento anaeróbio, desde que a biomassa esteja devidamente adaptada. Aos perfis temporais de concentração, realizados no ASBBR, foi ajustado um modelo de primeira ordem para consumo de substrato, na forma de DQO Total, obtendo valores de K1 variando entre 3,18 x \'10 POT.-5\' e 5,82 x \'10 POT.-5\' /(d.mgSTV/L). O pós-tratamento dos efluentes do ASBBR foi avaliado em um sistema de lodos ativados em batelada seqüencial, que obteve eficiência máxima da ordem de 30% em termos de remoção de DQO, com DQO afluente da ordem de 5.000 mg/L. Quanto ao filtro biológico anaeróbio de fluxo ascendente, obteve-se eficiências superiores a 70%, ao ser alimentado com uma mistura de lixiviado recalcitrante e etanol acidificado, com DQO afluente da ordem de 20.000 mg/L. / This work evaluated the tractability of landfill leachate from São Carlos-SP, utilizing biological reactors. The experiment was conducted at environmental temperature, in a pilot scale unity constructed into the São Carlos-SP landfill area. Initially, it was compared and tested two kinds of anaerobic reactors, each one with 1.200 L of total volume and both provided of mechanical agitation, differing by the kind of biomass immobilization, having the first (ASBR), self-immobilized biomass, and the second (ASBBR), immobilized biomass in polyurethane foam cubes. An approximately 120 L volume continuous up flow anaerobic biofilter was also evaluated. Additionally to the anaerobic treatment, it was also evaluated the post-treatment of landfill leachate in a sequence batch activated sludge system of 180 L. The ASBR, inoculated with a granular UASB sludge from a poultry wastewater treatment, was inefficient and presented sludge segregation and sedimentation problems. The ASBBR, inoculated using the sludge from the bottom of a landfill leachate reservoir, at the final of acclimation, presented efficiency over 70%, in terms of COD removal, utilizing landfill leachate without water dilution, with an inlet COD at the range of 11,000 mg/L, a TVA/COD ratio of approximately 0.6 and reaction time equal to 7 days. It was realized that the landfill leachate anaerobic biodegradability has a directly relationship to the TVA/COD ratio, and for TVA/COD Total ratio lower than 0.25, the biodegradability is low, for ratios between 0.25 and 0.40 is medium, and up to 0.40 may be considered high. It was also observed that \'NH IND.4\' POT.+\' concentrations at the range of 4,500 mg N/L has no significant interference in the anaerobic treatment, since the biomass has properly acclimated. At the temporal profiles of concentration performed in the ASBBR, it was adjusted a first order model for the substrate consumption, in terms of COD Total, obtaining K1 values ranging between 3.18 x \'10 POT.-5\' and 5.82 x \'10 POT.-5\' /(d.mgSTV/L). The post-treatment of the ASBBR effluents was evaluated in a sequence batch activated sludge system, which has obtained maximum efficiencies at the range of 30% in terms of COD removal, with an inlet COD at the range of 5,000 mg/L. As regards of the continuous up flow anaerobic biofilter, it has obtained efficiencies superiors to 70% when fed by a mixing of recovery landfill leachate and acidified ethanol, with an inlet COD at the range of 20,000 mg/L.
|
Page generated in 0.0519 seconds