• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 109
  • 36
  • 9
  • Tagged with
  • 151
  • 52
  • 27
  • 26
  • 21
  • 19
  • 18
  • 16
  • 14
  • 14
  • 13
  • 13
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Développement d'une plate-forme de biopuce compatible avec le diagnostic moléculaire des maladies infectieuses

Raymond, Frédéric 11 April 2018 (has links)
La technologie des biopuces permettrait une détection rapide et multiparamétrique des microorganismes infectieux et des gènes de résistance aux antibiotiques qui leur sont associés. Deux aspects des biopuces ont été étudiés durant ce projet. Premièrement, dans le but de faciliter la conception des sondes de capture, nous avons évalué l’influence de la position de la cible hybridée par une sonde. Nous avons observé que la longueur des chaînes non-hybridées dépassant de la sonde de capture avait une influence sur le signal d’hybridation obtenu et pouvait être responsable de faux-négatifs. Deuxièmement, afin de contribuer à éliminer la nécessité de l’amplification et du marquage des acides nucléiques cibles, nous avons développé une biopuce composée de sondes APN immobilisées sur une lame de verre. Cette biopuce permettra l’utilisation d’un polymère cationique senseur d’acides nucléiques comme transducteur de l’hybridation. / Biochip technology could allow rapid multiparametric diagnosis of infectious diseases and related antimicrobial resistance genes. Two aspects of biochips were studied during this project. First, to facilitate DNA or PNA capture probes design, we studied the impact on hybridisation signal of the position targeted by the probe. We observed that the length of the target’s non-hybridised overhangs had an influence on obtained hybridisation signal and that it could be responsible for false-negatives. Second, in order to contribute to the elimination of sample nucleic acids amplification and labelling before hybridisation, we developed a biochip made of PNA probes immobilised on a glass slides. This biochip allows detection using a soluble fluorescent cationic polythiophene that acts as hybridisation transducer.
62

Fabrication d'une sonde pour le champ proche optique en technologie sol-gel / Manufacturing of near-field optics probe using sol-gel technology

Mourched, Bachar 07 December 2012 (has links)
L'utilisation de la microscopie de champ proche optique SNOM reste très limitée dû aux difficultés de mise en œuvre instrumentale. La sonde de champ proche est le cœur du microscope et la maîtrise de son utilisation (suppression d'un certain nombre de réglages optiques) constitue la clé technique de l'accès de cette méthode à un plus grand nombre d'utilisateurs. Ces travaux de thèse s'effectuent dans le contexte d'un projet qui consiste à réaliser la preuve de concept d'une sonde novatrice en matériau hybride organique/minéral, de type levier, intégrant une fonction optique. Dans la première partie, une étude bibliographique retrace l'historique des microscopies et donne le principe du champ proche optique. Ensuite, les différentes sondes commerciales de type fibre optique ou cantilever, à ouverture ou sans ouverture, ou autre, leurs avantages et inconvénients, leurs techniques de fabrication et les principaux matériaux utilisés sont présentés. En se basant sur cette étude bibliographique, on propose une nouvelle sonde à pointe pleine en matériau hybride qui associe les avantages de chaque type de sonde. Les raisons du choix du matériau hybride comme matériau de base de la sonde et ses caractéristiques sont aussi présentées dans cette partie. Dans une deuxième partie on détaille le procédé de fabrication du matériau (synthèse) ainsi que le rôle des différentes étapes dans ce procédé et les changements réalisées suite à des modifications des paramètres de la synthèse. Une caractérisation de ce matériau est aussi réalisée dans cette partie en mesurant son indice de réfraction et son module d'Young. La troisième partie est consacrée à la détermination des dimensions de la sonde qui permettent de maximiser le transfert de puissance optique en émission et réception. Ceci est fait en se basant sur une étude plus théorique au travers de simulations. L'effet de plusieurs paramètres sur la propagation de la lumière dans la sonde est étudié (longueur, largeur, épaisseur et raideur du levier ainsi qu'ouverture à l'extrémité de la pointe). La quatrième partie est dédié à la réalisation des sondes "micropoutres sol-gel" et aux caractérisations mécaniques et optiques associées. Elle présente le procédé de fabrication optimisé de sondes optiques couplant la définition des sondes par méthode de masquage et leur libération par gravure réactive ionique et gravure au fluorure de xénon "DRIE + XeF2". A partir de ce procédé, des guides d'ondes optiques ont été réalisés et caractérisés permettant la détermination des pertes optiques et donc du coefficient d'absorption du matériau hybride développé. La conclusion présente les perspectives ouvertes et en cours de ce travail dans le cadre d'un projet plus global. . / .The use of near-field optical microscopy SNOM is still very limited due to difficulties in instrumental work. The probe is the heart of the microscope and control its use (removal of optical settings number) is the technique key to access this method to a larger number of users. This thesis work is realized in the context of a project to achieve a concept proof for an innovative probe organic / inorganic hybrid material, lever type, incorporating an optical function. In the first part, the history of microscopy and the principle of the optical near field are described in a literature study. Then, the various commercial probes of optical fiber or cantilever type, with aperture or apertureless, or otherwise, their advantages and disadvantages, their manufacturing techniques and the main materials used are presented. Based on this literature study, we propose a new probe full tip hybrid material that combines the advantages of each type of probe. The choice reasons of the hybrid material as base material of the probe and its characteristics are also presented in this part. In the second part we detail the manufacturing process of the material (synthesis) as well as each step role in this process and changes made in response to changes in the synthesis parameters. Characterization of this material is also carried out in this part by measuring its refractive index and its Young's modulus. The third part is devoted to the determination of the probe dimensions to maximize the optical transmission and collection power based on a theoretical study through simulations. Several parameters effect on the light propagation in the probe is also studied (length, width, thickness and stiffness of the lever and aperture towards the end of the tip). The fourth part is dedicated to the probe achievement in hybrid material and associated mechanical and optical characterizations. It presents the manufacturing optimized process of optical probes coupling masking defining method probes and releasing method by reactive ion etching and etching xenon fluoride "DRIE + XeF2". Using this process, optical waveguides were realized and characterized for the determination of optical losses and therefore the absorption coefficient of the developed hybrid material. The conclusion presents open perspectives as part of a larger project.
63

Contributions algorithmiques à la conception de sondes pour biopuces à ADN en environnements parallèles

Missaoui, Mohieddine 09 December 2009 (has links) (PDF)
Les microorganismes constituent la plus grande diversité du monde vivant et restent encore largement méconnus. La compréhension du fonctionnement des écosystèmes et les rôles joués par les microorganismes reste un enjeu majeur de l'écologie microbienne. Le développement de nouvelles approches de génomique permet d'appréhender la complexité de ces systèmes. Dans ce contexte, les puces à ADN représentent des outils à haut débit de choix capables de suivre l'expression ou la présence de plusieurs milliers de gènes en une seule expérience. Cependant, l'une des étapes les plus difficiles, de part sa complexité et la quantité de données à traiter, est la sélection de sondes qui doivent être à la fois sensibles et spécifiques. Pour répondre à ces besoins en termes de performance et de qualité, d'une part, nous avons développé un algorithme de conception de sondes pour biopuces phylogénétiques que nous avons entièrement déployé sur la grille de calcul européenne EGEE, et d'autre part, nous avons proposé un deuxième algorithme pour biopuces fonctionnelles que nous avons déployé sur un cluster. Les deux algorithmes ont nécessité une phase importante d'ingénierie logicielle. Nous avons donc proposé une démarche d'ingénierie dirigée par les modèles (IDM) et notamment de transformation de modèle pour résoudre le problème de traduction inverse d'oligopeptide. Les deux algorithmes sont destinés à une utilisation massive et permettent de concevoir tout type de sondes
64

Processus d'altération à la surface de Mars primitive : simulations expérimentales et numériques et implications minéralogiques / Process of deterioration on the primitive surface of Mars : experimental and digital simulations and mineralogical implications

Girard, Vincent 03 November 2010 (has links)
Depuis quinze ans, de multiples instruments de mesure ont été envoyés vers Mars et explorent aujourd'hui sa surface ou y sont en orbite. Les données, renvoyées par ces sondes ont fourni une grande quantité d'informations quant aux conditions régnant aujourd'hui sur Mars, mais aussi sur la géologie des terrains et sur la minéralogie associée. Les minéraux découverts sur Mars se sont formés dans des conditions tout à fait différentes de celles qui y règnent aujourd'hui.Une approche associant modélisations numériques et expériences est proposée pour permettre d'identifier l'influence de divers processus comme le rayonnement UVC, la température et la pression partielle de CO2 ou de SO2. Des expériences en boîte à gants sont réalisées à des pressions partielles de CO2 de 10-6 bar, 10-3 bar et 10-2 bar, en présence ou non de rayonnement UVC. Conjointement à ces expériences, des expériences en capsules en or sont menées pour des températures de 20°C et 50°C avec des pressions partielles de CO2 d'environ 10-3 bar, 10-2 bar et 1 bar ainsi qu'avec une pression partielle de SO2 d'environ 1 bar. Les résultats ont montré qu'il était possible de reproduire expérimentalement et par les codes de calculs, la minéralogie supposée résultant de l'altération d'un verre basaltique de composition proche de roches martiennes. L'observation de carbonates de calcium dans les expériences réalisées à des pressions partielles de CO2 supérieures à 10-3 bar est en accord avec la prédiction de ces mêmes minéraux par des simulations numériques réalisées avec le logiciel DISSOL. Néanmoins, l'abondance de ces carbonates dans les deux types de modélisations, ainsi que leur composition à dominance calcique, contrastent avec les observations des rares minéraux carbonatés magnésiens à la surface de Mars. Ce contraste pose les questions concernant la composition de l'atmosphère, la composition initiale du verre et la préservation des carbonates après leur précipitation. Bien que des argiles n'aient pas été observées dans les expériences à cause d'un taux de dissolution du verre trop faible, des montmorillonites ferrifères et magnésiennes sont prédites dans les simulations numériques quelle que soit la pression partielle de CO2. De la beidellite sodique est également prédite dans le cas où les conditions atmosphériques martiennes seraient réductrices quelle que soit la pression partielle de CO2. Contrairement aux observations de la surface de Mars, aucune nontronite ne précipite. Les sulfates sont absents des paragenèses minérales obtenues lors des expériences avec une atmosphère à CO2. Dans les modélisations, aucun minéral sulfaté n'est néoformé pour les pressions partielles de CO2 imposées (> 10-6 bar) et la teneur en soufre du verre expérimental de synthèse. Toutefois, la précipitation de gypse peut être observée dans les simulations si la teneur en soufre est 100 fois supérieure à celle du verre utilisé pour ce travail. L'absence de sulfates magnésiens, de même que de carbonates magnésiens suggère que la composition chimique choisie pour le verre soumis à l'altération ne correspond pas totalement celle de la roche qui a pu donner les différents assemblages minéralogiques observés à la surface de Mars. En revanche, des sulfates de calcium et, des sulfates de fer et d'aluminium sont observés pour des expériences en capsules avec une atmosphère à SO2. Le rôle des atmosphères est essentiel quant à l'abondance des minéraux carbonatés et des minéraux sulfatés. Les expériences montrent que les radiations UVC accélèrent la dissolution du verre et favorise l'oxydation partielle du soufre du verre en pyrite / Process of deterioration on the primitive surface of Mars: experimental and digital simulations and mineralogical implications
65

Development of Auto-Immolative Spacers for Probes of Enzyme Activity / Développement d’espaceurs auto-effondrables pour des sondes d’activité enzymatique

Thörn Seshold, Oliver 27 June 2013 (has links)
Cette thèse traite de la conception et mise en œuvre d’espaceurs auto-effondrables novateurs pour une utilisation dans des sondes d’activité enzymatique in vivo.La première partie détaille la synthèse et la validation in vitro d’espaceurs cyclisant, couplant l’activité d’un aminopeptidase à la libération d’un phénol. Les sondes fluorogènes modulaires basées sur ces espaceurs 1,2-diamine sont très robustes (demi-vie > 560 h), mais sont rapidement enzymatiquement hydrolysées, et puis relâchent rapidement (demi-temps ~ 3 min) un fluorophore ESIPT insoluble et exceptionnellement photostable.Ces sondes ont une excellente sensibilité (rapport signal:contrôle > 3000:1), et fournissent la première démonstration d’un système macroscopiquement binaire éteint–ALLUMÉ, pour la libération de phénols sous activité d’aminopeptidases. Ce système pourrait permettre de faire de l’imagerie moléculaire ultra-sensible d’une gamme d’exopeptidases. Ces espaceurs pourraient également servir dans des sondes comportant d’autres fluorophores phénoliques, dans des promédicaments de phénols/alcools activés par des peptidases spécifiques (thérapies ciblées), ou comme adaptateurs chimiques en générale.La deuxième partie détaille les synthèses de deux familles d’espaceurs tautomérisant/éliminant pour utilisation dans des sondes magnétogènes d’activité de glycosidases. Les premières architectures substrat-espaceur basées sur des 2-furanols et des carbimidates cycliques ont été explorées. Notamment, des glycosides 2-furanoliques ont été abordés comme espaceurs énergétiques alternatifs aux quinone méthydes, et des carbimidates ont été explorés comme espaceurs pour ligands modèles des sondes promagnétiques. / This thesis concerns the design and implementation of novel auto-immolative spacers for use in probes for enzymatic activity in vivo.The first part relates the development and in vitro validation of cyclisation spacers which couple the action of an aminopeptidase to the release of a phenol. The modular three-component fluorogenic probes based on these 1,2-diamine spacers are very robust (halflife > 560 h), but are also rapidly enzymatically processed, and quickly (halftime ~3 min) release an exceptionally photostable, insoluble ESIPT fluorophore. The probes have excellent detection sensitivity relative to current methods (signal to control ratio > 3000:1), and provide the first demonstration of a macroscopically binary off–ON system for phenol-releasing probes of aminopeptidase activity. The probe system may allow the exceptionally sensitive, ESIPT-based molecular imaging of a range of exopeptidases. The spacers may also be applied in off ON peptidase probes of other phenolic fluorophores, to peptidase-specific phenol/alcohol prodrugs for targeted therapy, or more generally in chemical adapter technologies.In the second part, two novel families of auto-immolative elimination/tautomerisation spacers were designed for use in three-component off ON magnetogenic probes sensing glycosidase activity. The first known substrate-spacer designs based on 2-hydroxyfurans and on carbimidates were explored. Notably, 2 furanol glycosides were synthesised in pursuit of high-energy alternatives to quinone methides, and a general method for preparing model carbimidate-bearing ligands for pro-magnetic probes was elaborated.
66

Sondes moléculaires comprenant des espaceurs auto-effondrables multifonctionnels pour la détection d'activités enzymatiques / Molecular probes containing self-immolative spacer for the detection of enzyme activities

Prost, Maxime 17 July 2014 (has links)
Cette thèse traite de la conception de sondes fluorogènes incorporant des bras espaceurs auto-effondrables répondant à l’activité enzymatique.Ces travaux commencent par la synthèse d’une sonde modèle à trois composantes pour détecter l’activité de la Leucine AminoPeptidase (LAP). Le cœur de cette sonde est un espaceur cyclisant efficace (t1/2 cyclisation≈7sec) qui unit un substrat enzymatique à un fluorophore précipitant avec une stabilité exemplaire (pas de dégradation sur 15h d’incubation). Appliquée sur des cellules vivantes, cette sonde produit des précipités fluorescents qui marquent durablement les cellules. L’élaboration de sondes pour d’autres enzymes a cependant soulevé l’importance d’abaisser le seuil de solubilité du fluorophore.Cette thèse se penche également sur deux nouvelles conceptions de sondes à la spécificité améliorée. Alors que la première tente de réutiliser les efforts déployés pour obtenir des inhibiteurs hautement sélectifs, la seconde est basée sur deux transformations successives par deux enzymes indépendantes. Si la première solution a échoué jusqu’alors, la seconde nous a effectivement permis de différencier des populations cellulaires.Enfin, ce manuscrit détaille le développement d’une nouvelle génération d’espaceur permettant l’affinement de certaines propriétés des sondes. Focalisés sur l’amélioration de l’hydrosolubilité, les premiers exemples sont très prometteurs. Particulièrement, une sonde pour Péncilline G Amidase possède une hydrosolubilité 3500 fois supérieure à celle de son analogue commercial. Véritables multiprises chimiques, ces espaceurs devraient permettent de relever certains des grands défis de la chimie médicinale moderne. / This thesis concerns the design and evaluation of fluorogenic molecular probes that respond to enzyme activity via the help of self-immolative spacers.This work starts with the synthesis of a model three-component probe that detects the activity of Leucine AminoPeptidase (LAP). The heart of this probe is an efficient cyclizing spacer (t1/2 cyclization≈7sec) that links a specific enzyme substrate to a precipitating fluorophore with an exemplary stability (no false positive signal over 15h incubation). When incubated with live cells, this construct is processed by active LAP to yield fluorescent precipitates which lead to long-term cell-tagging. However, probes susceptible to other enzyme activity have indicated the interest in further reduction of the solubility threshold of ELF®97.This manuscript also describes two new strategies to improve the specificity of the probes. While the first tries to take advantage of the efforts made to develop highly selective inhibitors, the second is based on two consecutive transformations by two independent enzymes. The first strategy has not yet been successfully applied in our hands, but the second has led to a first prototype that allowed discriminating between different cell lines.Lastly, this thesis relates the design and synthesis of a new generation of cyclizing spacer which opens up a great number of possibilities to optimize probes’ properties. For example, a probe targeting Pencilline G Amidase and containing such a spacer possesses a hydrosolubility 3500 times higher than its commercial analogue. As true “molecular hubs”, these spacers may turn out to address the big challenges of modern imaging agent and prodrug development.
67

Novel bioorthogonal chemical reporters and fluorogenic probes for biomolecules imaging / Nouveaux rapporteurs chimiques et sondes fluorogènes bioorthogonaux pour l'imagerie de biomolécules

Favre, Camille 14 June 2019 (has links)
L'imagerie de biomolécules, et plus particulièrement des glycanes, au sein d'organismes vivants, représente un incroyable challenge. Cependant, des progrès significatifs ont été réalisés ces dix dernières années grâce au développement de la stratégie du rapporteur chimique bioorthogonal. Cette technique implique, dans un premier temps, l'incorporation d'une fonctionnalité chimique non native (rapporteur) au sein de biomolécules complexes. Ce rapporteur peut ensuite réagir sélectivement avec une sonde moléculaire spécifique permettant ainsi la détection de la biomolécule ciblée. Afin d'imager ces biomolécules en temps réel, les sondes fluorogènes, des réactifs non fluorescents qui deviennent fluorescents après réaction avec le rapporteur chimique, ont été récemment développées. Ces dernières années, la cycloaddition 1,3-dipolaire sans métaux, entre les cylooctynes et les azotures, a été élégamment employée comme réaction bioorthogonale pour l'imagerie de biomolécules au sein d'organismes vivants. Cependant, l'azoture présente certaines limitations, notamment il peut être réduit par les thiols cellulaires. En conséquence, nous avons étudié l'utilisation de 1,3-dipôles plus stables, en tant que nouveaux rapporteurs chimiques bioorthogonaux pour l'imagerie de biomolécules par fluorescence. De plus, nous avons aussi développé de nouvelles sondes fluorogènes bioorthogonales ayant de bonnes propriétés de fluorescence, telles que de hautes valeurs de rendement quantique et des longueurs d'ondes d'émission déplacées dans le rouge, pour une potentielle application chez l'animal. / Imaging biomolecules, such as glycans, in living systems remains a formidable chemical challenge. However, significant progress has been made over the past ten years, with the ground-breaking development of the bioorthogonal chemical reporter strategy. In this context, complex biomolecules are fitted with a non-native chemical functionality (reporter) that can react selectively with a complementary bioorthogonal probe for detection. In order to image these biomolecules in real time, fluorogenic probes, non fluorescent reagents that produce highly fluorescent products, have recently been developed. This last decade, the metal-free 1,3-dipolar cycloaddition between cyclooctynes and azides have been elegantly employed for biomolecules imaging in living systems. However, azides suffer from limitations such as their reduction by endogenous cellular thiols. Consequently, we have investigated the use of more stable 1,3-dipoles as new chemical reporters for fluorescent biomolecule imaging. In addition, we also developed novel bioorthogonal fluorogenic probes with improved fluorescence properties such as high quantum yields and red-shifted fluorescence emission for potential applications in living animals.
68

Étude de l'effet d'ondes électromagnétiques sur le fonctionnement de circuits électroniques – Mise en place d'une méthode de test des systèmes

Dubois, Tristan 21 October 2009 (has links) (PDF)
De nos jours, les systèmes de communication sans fil et d'imagerie sont devenus indispensables. Ces applications, tant civiles que militaires, doivent avoir une sûreté de fonctionnement éprouvée, et ce dans tous les domaines dont celui de la compatibilité électromagnétique. Pourtant les circuits électroniques complexes au coeur de ces systèmes voient leur seuil de susceptibilité électromagnétique diminuer. Cette diminution est causée premièrement par une augmentation de la fréquence de fonctionnement des circuits et deuxièmement par la réduction de leurs tensions d'alimentation. Dans ce contexte, ce travail de thèse a pour but de mettre en avant les effets d'agressions électromagnétiques sur un système électronique hyperfréquence complexe en suivant une méthode de test. Le principe consiste à étudier chaque circuit du système indépendamment les uns des autres. Ces différents circuits sont ensuite associés pour former une boucle à verrouillage de phase (PLL). La susceptibilité du système global est alors étudiée. Pour ces études de susceptibilité, nous utilisons un banc de caractérisation électromagnétique en zone de champ proche. Les sondes à base de câbles coaxiaux sont caractérisées. Nous avons d'abord étudié l'effet d'un signal d'agression hyperfréquence sur le comportement d'une diode Schottky. Nous avons mis en évidence sur le système diode – ligne, des phénomènes de résonance sur les pistes du circuit imprimé. L'ensemble de cette étude nous sert d'approche préliminaire pour l'analyse de la susceptibilité de la boucle à verrouillage de phase. En suivant la méthodologie décrite précédemment nous avons pu montrer plusieurs effets d'agressions électromagnétiques sur des circuits électroniques actifs du type oscillateur, amplificateur et comparateur de phase. L'élaboration d'une hiérarchie de ces effets a permis de déterminer la contribution de chacun de ces circuits sur la susceptibilité électromagnétique du système PLL.
69

ETUDE EXPERIMENTALE D'UN ECOULEMENT DIPHASIQUE DE TAYLOR COUETTE

Mehel, Amine 20 June 2006 (has links) (PDF)
Ce travail de thèse vise à étudier expérimentalement les mécanismes d'interaction entre les structures de la turbulence et une phase dispersée (gaz ou vapeur) dans une expérience de Taylor Couette avec rotation du cylindre intérieur. Cette étude a été réalisée pour des régimes d'écoulement correspondant aux régimes chaotique (Ta=780), faiblement turbulent (Ta=1000) et turbulent (Ta=4500). La phase dispersée sous forme de bulles, de tailles variées, a été introduite soit par ventilation par agitation de la surface libre, soit par injection associée à une mise en dépression de l'installation. L'intrusion de sondes optiques doubles a permis de caractériser l'arrangement de la phase dispersée (localisation des bulles dans l'entrefer) ainsi que le taux de vide, la taille et la vitesse des bulles. Afin de caractériser la dynamique de l'écoulement, des visualisations couplées à des mesures du champ de vitesse par vélocimétrie Laser Doppler ont été effectuées dans l'entrefer. Des comparaisons fines entre la dynamique du liquide en présence de bulles et celle obtenue en écoulement monophasique ont permis de mettre en évidence les interactions et les mécanismes de couplages ou d'échange entre la structure de l'écoulement et la phase dispersée. En ce qui concerne l'arrangement de la phase dispersée, les résultats ont montré que les bulles de taille millimétrique sont en partie capturées par les cellules de Taylor, une cellule sur deux et en partie localisées dans les zones de jet (outflow) près du cylindre intérieur. Les bulles sub-millimétriques sont essentiellement localisées en région de outflow près du cylindre intérieur mais de manière plus diffuse dans l'entrefer. En ce qui concerne les mécanismes d'interaction entre les bulles et la dynamique du champ de vitesse liquide, il a été montré que les bulles localisées au coeur des cellules contribuent à stabiliser l'écoulement par augmentation de la vorticité alors que les bulles localisées en proche paroi du cylindre intérieur (dans la zone de jet) contribuent à développer la turbulence par augmentation du cisaillement dépendant de la taille des bulles. On a observé globalement un gain d'énergie cinétique turbulente en écoulement diphasique de Taylor Couette principalement dû au travail de cisaillement.
70

Développement, étude de performances et intégration de sondes thermiques pour la caractérisation de l'encrassement d'échangeurs tubulaires à courants croisés

Perez, Laetitia 12 1900 (has links) (PDF)
Depuis la fin des années 1970, les échangeurs de chaleur ont connu de nouvelles applications liées à la nécessité d'optimiser les dépenses énergétiques. L'encrassement de tels échangeurs est l'une des causes principales de leur perte d'efficacité thermique au cours de leur utilisation. En effet, l'encrassement constitue un problème économique et technologique majeur et fait intervenir des phénomènes physiques complexes. En dépit des efforts déployés depuis ces dernières décennies, les dispositifs de détection et de suivi de l'encrassement existants sont encore loin de renseigner sur le transfert de chaleur et de prendre en compte les phénomènes de dépôt mis en jeu. Ainsi, le parti pris de notre étude a été de concevoir un capteur thermique le plus représentatif possible des conditions d'utilisation réelles afin d'établir un programme d'entretien efficace. A cet effet, deux capteurs localisés originaux, d'une technologie simple, adjoints à un traitement des données adapté, ont été développés. Ne perturbant que très peu les conditions auxquelles ils sont soumis, ils permettent d'obtenir des informations précises quasi instantanées sur les paramètres représentatifs du degré d'encrassement des échangeurs. Bien que les méthodes développées lors de cette étude soient adaptables à d'autres configurations, le choix, incontestablement restrictif, de travailler sur l'encrassement particulaire des échangeurs tubulaires à courants croisés, a été fait. Le premier capteur, doté d'une excitation thermique interne, permet d'estimer non seulement le coefficient d'échange convectif mais aussi l'épaisseur du dépôt à partir d'une méthode d'estimation robuste en régime transitoire. Le second capteur permet d'estimer la répartition spatiale du coefficient d'échange convectif ainsi que celle de l'épaisseur de dépôt. Ces capteurs permettent d'envisager de nouvelles perspectives d'études in situ d'encrassement en milieu industriel. Ils constituent un outil privilégié de maintenance prédictive.

Page generated in 0.057 seconds