Mercury leaching from dental amalgam fillings and its association with urinary zincZanager, Afaf Mohamed January 2019 (has links)
Magister Scientiae (Medical Bioscience) - MSc(MBS) / Mercury (Hg) is an example of a toxic metal that is not essential for nutrition. It exists in organic and inorganic forms in seafood and vapour from dental amalgam fillings respectively. Elemental mercury (Hg0) from dental amalgam was the focus of this study. Dental amalgam is one of the most commonly used dental filling materials and has been used for over 150 years. It is composed of Hg0 (approximately 50%) combined with other metals such as copper and zinc (Zn). These fillings give off Hg0 vapour throughout their existence, and is further enhanced by activities such as chewing, grinding of teeth and drinking hot liquids. Mercury consumption can lead to Zn loss or deficiency, and is reported to displace Zn and copper. Several European nations have outlawed the use of amalgam as a restorative material due to controversies regarding its safety in children, women of childbearing age and individuals with renal disease. Moreover, various studies have reported correlations between the number of amalgam fillings and Hg concentration in blood plasma, urine, faeces, saliva and different organs. Blood, urine, and hair mercury levels are used to predict possible health effects that may be caused by the different forms of Hg. Urine Hg is used to test exposure to metallic Hg0 vapour and inorganic Hg forms.
This study aimed to evaluate the effects of Hg0 from dental amalgam restorations on the status of Zn in the urine. This was done by determining the concentrations of Hg0 in urine, buccal cells and the oral cavity, and its relationship with urinary Zn concentrations in the same individuals. Samples of urine, buccal tissues, chewing gum and completed questionnaires were collected from the participants (women
and men) at the dental clinics in Tygerberg Hospital (TBH), Cape Town. Samples were analyzed using inductively coupled plasma mass spectrometer (ICP-MS).
Findings from this study show that there was a correlation between levels of urinary Hg0 and urinary Zn (p=0.02). However, urinary Hg0 did not predict the amount of urinary Zn. Also, no relationship was found between levels of Hg0 in buccal swab or the chew test samples and urinary Zn level. There was a significant difference between females and males in the level of urinary Zn, men had higher levels of Zn excreted in the urine than females (p=0.05). However, there was no significant difference in the level of urinary Hg0 between males and females. The number of fillings (4-7) and age of fillings were significantly associated with urinary Hg0 level (p˂0.05), while smoking ˃15 cigarettes/day increased the level of Hg0 in buccal swab samples (p=0.002). We were not able to demonstrate a causal effect of Hg0 leaching on urinary zinc levels.
|
2 |
Enhanced gel electrophoresis (GE) and inductively coupled plasma-mass spectrometry (ICP-MS) based methods for the identification and separation of proteins and peptidesHaider, Syed January 2012 (has links)
The main focus of the PhD study was to develop new gel electrophoresis and ICP-MS based methods to analyze a wide variety of the bio-molecules such as proteins, phosphoproteins and metalloproteins etc. The tricine-sodium dodecyl sulfate-polyacrylamide gel electrophoresis (tricine-SDS-PAGE) method is commonly used to resolve low molecular mass proteins, however, it requires a high percentage gel and a very complicated procedure to achieve this separation. This study describes a modification to tricine-SDS-PAGE to make it more effective for the separation of smaller proteins and for coupling to ICP-MS. The modified method employs low percentage PAGE gels and low reagent concentrations that provide efficient separations, good quantitation and low matrix levels that are compatible with ICP-MS. This modified method was applied to analyze phosphopeptides. Phosphopeptides are very small in size and difficult to separate using the other techniques such as Laemmli SDS-PAGE, original tricine-SDS-PAGE, immobilized metal affinity chromatography (IMAC), size exclusion chromatography (SEC) etc. In this study a simplified procedure is described based on modifying the original tricine-SDS-PAGE method. A comparative study showed that this modified method successfully resolved a digest mixture of very low to high molecular mass phosphopeptides/peptides. In off-line coupling of this method with ICP-MS, much better recoveries of the peptides from the gel were obtained as compared to traditional methods which indicate the compatibility of this modified method for quantitative studies. An on-line coupling of the modified system with ICP-MS was also demonstrated and it was applied for the separation, detection and quantification of phosphopeptides. Another application of this modified system was the separation of serum proteins. Blood serum contains five major protein groups i.e., albumin, alpha-1 globulin, alpha-2 globulin, beta globulin and gamma globulin. The separation of these five major proteins in a single gel is difficult to achieve using traditional methods. The modified system was shown to be superior for the separation of these serum proteins in a 7% (m/v) native-PAGE gel and a cellulose acetate membrane. A further study was carried out into controlling the factors that cause metal loss and protein fragmentation in SDS-PAGE. Using a reducing sample buffer, and heating to high temperatures (90-100ºC) in alkaline or acidic conditions may cause protein fragmentation and decrease the metal binding affinity. 70ºC was found suitable to prepare the sample at neutral, alkaline or acidic pH as no fragmentation observed. To prevent metal loss, the binding constant (log K) values of metal-amino acids, play the major role. Those metals which have high binding affinities with the amino acids in proteins can also be affected by the variation of the pH so prior information about pH to maintain the binding constant values is essential to minimize metal loss. This was observed in the loss of zinc, and to a lesser extent copper from human serum albumin (HSA) as measured by inductively coupled plasma mass spectrometry (ICP-MS). The method described above was applied for the separation and quantification of the serum proteins obtained from age-related macular degeneration (AMD) patients (where the AMD patients were from Moorfields Eye Hospital, London). Zn and Cu were quantified employing external calibration. Zn concentration showed variation whilst Cu did not show any significant variations in samples from AMD patients. A brief study of the interaction of cisplatin and oxaliplatin with HSA and transferrin was also performed. Cisplatin bound much faster than oxaliplatin with HSA. After 24 hours incubation, cisplatin showed a decrease in signal intensity which indicates that cisplatin binding decreases with time. Cisplatin binding with transferrin as compared to HSA was not significant, which could be the result of unstable Pt-transferrin complex formation. Oxaliplatin did not show high binding to either protein, perhaps due to the presence of the bulky, non polar DACH ligand.
|
3 |
Avaliação do uso da cela de reação dinâmica em espectrometria de massas com plasma acoplado indutivamente (DRC-ICP-MS) para determinação de elementos químicos em sangue / Evaluation of the use of dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) for determination of elements in whole bloodBatista, Bruno Lemos 30 April 2009 (has links)
A espectrometria de massas com plasma acoplado indutivamente com simples quadrupolo (q-ICP-MS) e cela de reação dinâmica (DRC-ICP-MS) foi avaliada para determinação seqüencial de Al, As, Cd, Co, Cu, Cr, Mn, Mo, Pb, Pt, Sb, Se, Sn, Te, Tl, V e Zn em sangue. Para as análises, amostras de sangue (200 µL) foram diluídas 1:50 em uma solução contendo 0,01% v/v Triton® X-100 e 0,5% v/v de ácido nítrico. As calibrações foram realizadas com ajuste de matriz, utilizando sangue ovino. Como gás de reação utilizou-se a NH3. O uso do DRC foi fundamental para a determinação de Cr e V. A escolha da melhor vazão do gás e a otimização do parâmetro de rejeição (RPq) foram estudadas utilizando sangue base ovino ou uma solução de matriz sintética (SMS), de acordo com a concentração do analito no sangue base. Os limites de detecção (3s/coeficiente angular) para determinação de 27Al, 75As, 111Cd, 59Co, 63Cu, 55Mn, 98Mo, 208Pb, 195Pt, 123Sb, 82Se, 120Sn, 130Te, 205Tl e 66Zn em sangue por q-ICP-MS foram 0,223; 0,014; 0,003; 0,011; 0,304; 0,009; 0,009; 0,003; 0,001; 0,005; 0,264; 0,006; 0,010; 0,001; 0,834 µg L-1, respectivamente, e para determinação de 52Cr e 51V em sangue por DRC-ICP-MS utilizando o gás de reação amônia os limites de detecção foram de 0,007 e 0,006 µg L-1. Para a determinação de 27Al, 63Cu, 65Cu, 64Zn e 66Zn em sangue por q-ICP-MS através da calibração com ajuste de matriz com SMS os limites de detecção foram 0,083; 0,090; 0,055; 0,281; 0,306 µg L-1, respectivamente. A validação do método foi realizada por meio da análise de materiais de referência do INSP-Canadá, NYSDOH-EUA e Seronorm-Noruega. / The use of inductively coupled plasma mass spectrometry with quadrupole (q-ICP-MS) and dynamic reaction cell (DRC-ICP-MS) was evaluated for sequential determination of Al, As, Cd, Co, Cu, Cr, Mn, Mo, Pb, Pt, Sb, Se, Sn, Te, Tl, V and Zn in whole blood by q-ICP-MS or DRC-ICP-MS methods. Prior to analysis, sample (200 µL) were diluted 1:50 v/v in a solution containing 0.01% v/v Triton® X-100 and 0.5% v/v nitric acid. For all elements, except Cr and V, the instrument was operated in q-ICP-MS mode. The use of DRC was only mandatory for Cr and V. NH3 was evaluated as the reaction gas. Selection of best flow rate of reaction gas and optimization of the quadrupole dynamic bandpass rejection parameter (RPq) were carried out, using base whole blood or synthetic matrix solution (SMS), in according with element base blood concentration. Method detection limits (3s/slope) for 27Al, 75As, 111Cd, 59Co, 63Cu, 55Mn, 98Mo, 208Pb, 195Pt, 123Sb, 82Se, 120Sn, 130Te, 205Tl and 66Zn determination in whole blood by q-ICP-MS against matrix matching calibration (base blood) were 0.223; 0.014; 0.003; 0.011; 0.304; 0.009; 0.009; 0.003; 0.001; 0.005; 0.264; 0.006; 0.010; 0.001; 0.834 µg L-1, respectively, and for 52Cr and 51V determination in whole blood by DRC-ICP-MS the detection limits were 0.007 e 0.006 µg L-1. For 27Al, 63Cu, 65Cu, 64Zn and 66Zn determination by q-ICP-MS through matrix matching calibration with SMS the detection limits were 0.083; 0.090; 0.055; 0.281; 0.306 µg L-1, respectively. Method validation was accomplished by the analysis of reference materials from INSP-Canada, NYSDOH-USA, Seronorm-Norway.
|
4 |
Avaliação do uso da cela de reação dinâmica em espectrometria de massas com plasma acoplado indutivamente (DRC-ICP-MS) para determinação de elementos químicos em sangue / Evaluation of the use of dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) for determination of elements in whole bloodBruno Lemos Batista 30 April 2009 (has links)
A espectrometria de massas com plasma acoplado indutivamente com simples quadrupolo (q-ICP-MS) e cela de reação dinâmica (DRC-ICP-MS) foi avaliada para determinação seqüencial de Al, As, Cd, Co, Cu, Cr, Mn, Mo, Pb, Pt, Sb, Se, Sn, Te, Tl, V e Zn em sangue. Para as análises, amostras de sangue (200 µL) foram diluídas 1:50 em uma solução contendo 0,01% v/v Triton® X-100 e 0,5% v/v de ácido nítrico. As calibrações foram realizadas com ajuste de matriz, utilizando sangue ovino. Como gás de reação utilizou-se a NH3. O uso do DRC foi fundamental para a determinação de Cr e V. A escolha da melhor vazão do gás e a otimização do parâmetro de rejeição (RPq) foram estudadas utilizando sangue base ovino ou uma solução de matriz sintética (SMS), de acordo com a concentração do analito no sangue base. Os limites de detecção (3s/coeficiente angular) para determinação de 27Al, 75As, 111Cd, 59Co, 63Cu, 55Mn, 98Mo, 208Pb, 195Pt, 123Sb, 82Se, 120Sn, 130Te, 205Tl e 66Zn em sangue por q-ICP-MS foram 0,223; 0,014; 0,003; 0,011; 0,304; 0,009; 0,009; 0,003; 0,001; 0,005; 0,264; 0,006; 0,010; 0,001; 0,834 µg L-1, respectivamente, e para determinação de 52Cr e 51V em sangue por DRC-ICP-MS utilizando o gás de reação amônia os limites de detecção foram de 0,007 e 0,006 µg L-1. Para a determinação de 27Al, 63Cu, 65Cu, 64Zn e 66Zn em sangue por q-ICP-MS através da calibração com ajuste de matriz com SMS os limites de detecção foram 0,083; 0,090; 0,055; 0,281; 0,306 µg L-1, respectivamente. A validação do método foi realizada por meio da análise de materiais de referência do INSP-Canadá, NYSDOH-EUA e Seronorm-Noruega. / The use of inductively coupled plasma mass spectrometry with quadrupole (q-ICP-MS) and dynamic reaction cell (DRC-ICP-MS) was evaluated for sequential determination of Al, As, Cd, Co, Cu, Cr, Mn, Mo, Pb, Pt, Sb, Se, Sn, Te, Tl, V and Zn in whole blood by q-ICP-MS or DRC-ICP-MS methods. Prior to analysis, sample (200 µL) were diluted 1:50 v/v in a solution containing 0.01% v/v Triton® X-100 and 0.5% v/v nitric acid. For all elements, except Cr and V, the instrument was operated in q-ICP-MS mode. The use of DRC was only mandatory for Cr and V. NH3 was evaluated as the reaction gas. Selection of best flow rate of reaction gas and optimization of the quadrupole dynamic bandpass rejection parameter (RPq) were carried out, using base whole blood or synthetic matrix solution (SMS), in according with element base blood concentration. Method detection limits (3s/slope) for 27Al, 75As, 111Cd, 59Co, 63Cu, 55Mn, 98Mo, 208Pb, 195Pt, 123Sb, 82Se, 120Sn, 130Te, 205Tl and 66Zn determination in whole blood by q-ICP-MS against matrix matching calibration (base blood) were 0.223; 0.014; 0.003; 0.011; 0.304; 0.009; 0.009; 0.003; 0.001; 0.005; 0.264; 0.006; 0.010; 0.001; 0.834 µg L-1, respectively, and for 52Cr and 51V determination in whole blood by DRC-ICP-MS the detection limits were 0.007 e 0.006 µg L-1. For 27Al, 63Cu, 65Cu, 64Zn and 66Zn determination by q-ICP-MS through matrix matching calibration with SMS the detection limits were 0.083; 0.090; 0.055; 0.281; 0.306 µg L-1, respectively. Method validation was accomplished by the analysis of reference materials from INSP-Canada, NYSDOH-USA, Seronorm-Norway.
|
5 |
Ionic Characterization of Laundry Detergents: Implications for Consumer Choice and Inland Freshwater SalinizationMendoza, Kent Gregory 11 April 2024 (has links)
Increased salinity in freshwater systems – also called the Freshwater Salinization Syndrome (FSS) – can have far-ranging implications for the natural and built environment, agriculture, and public health at large. Such risks are clearly on display in the Occoquan Reservoir – a drinking water source for roughly one million people in the northern Virginia/ National Capital Region. Sodium concentrations in the Occoquan Reservoir are approaching levels that can affect taste and health. The Reservoir is also noteworthy as a flagship example of indirect potable reuse, which further adds complexity to understanding the sources of rising levels of sodium and other types of salinity. To help understand the role residential discharges might play in salinization of the Occoquan Reservoir, a suite of laundry detergent products was identified based upon survey data collected in the northern Virginia region. The ionic compositions of these products were then characterized using ion chromatography and inductively coupled plasma-mass spectrometry to quantify select ionic and elemental analytes. Sodium, chloride, and sulfate were consistently found in appreciable amounts. To comparatively characterize the laundry detergents, principal component analysis was employed to identify clusters of similar products. The physical formulation of the products was identified as a marker for their content, with dry formulations (free-flowing and encapsulated powders) being more enriched in sodium and sulfate. This result was corroborated by comparing nonparametric bootstrap intervals for individual analytes. The study's findings suggest an opportunity wherein consumer choice can play a role in mediating residential salt inputs in receiving bodies such as the Occoquan Reservoir. / Master of Science / Many streams, rivers, and other freshwater systems have become increasingly salty in recent decades. A rise in salinity can be problematic, stressing aquatic life, corroding pipes, and even enhancing the release of more pollutants into the water. This phenomenon, called Freshwater Salinization Syndrome, can threaten such systems' ability to serve as sources of drinking water, as is the case for the Occoquan Reservoir in northern Virginia. Serving roughly one million people, the Reservoir is notable for being one of the first in the country to purposely incorporate highly treated wastewater upstream of a drinking water supply. Despite the Reservoir's prominence, the reasons behind its rising salt levels are not well understood. This study sought to understand the role that individual residences could play when household products travel down the drain and are ultimately discharged into the watershed. Laundry detergents are potentially high-salt products. A survey of northern Virginian's laundry habits was conducted to understand local tastes and preferences. Informed by the survey, a suite of laundry detergents was chemically characterized to measure salt and element concentrations. The detergents were found to have notable amounts of sodium, chloride, and sulfate in particular, with sodium being the most abundant analyte in every detergent. However, not all detergents were equally salty; statistical tools revealed that dry formulations (such as powdered and powder-filled pak detergents) contributed more sodium and sulfate, among other things. This study's findings suggest that laundry detergents could be contributing to Freshwater Salinization Syndrome in the Occoquan Reservoir, and that local consumers' choice of detergents could make a difference.
|
6 |
Analytical methodologies based on X-Ray Fluorescence Spectrometry (XRF) and Inductively Couple Plasma Spectroscopy (ICP) for the assessment of metal dispersal around mining environmentsMarguí Grabulosa, Eva 19 May 2006 (has links)
La investigació que es presenta en aquesta tesi es centra en l'aplicació i millora de metodologies analítiques existents i el desenvolupament de nous procediments que poden ser utilitzats per a l'estudi dels efectes ambientals de la dispersió dels metalls entorn a les zones mineres abandonades.En primer lloc, es van aplicar diferents procediments d'extracció simple i seqüencial per a estudiar la mobilitat, perillositat i bio-disponibilitat dels metalls continguts en residus miners de característiques diferents. Per altra banda, per a estudiar les fonts potencials de Pb en la vegetació de les zones mineres d'estudi, una metodologia basada en la utilització de les relacions isotòpiques de Pb determinades mitjançant ICP-MS va ser avaluada. Finalment, tenint en compte l'elevat nombre de mostres analitzades per a avaluar l'impacte de les activitats mineres, es va considerar apropiat el desenvolupament de mètodes analítics d'elevada productivitat. En aquest sentit la implementació d'estratègies quantitatives així com l'aplicació de les millores instrumentals en els equips de XRF han estat avaluades per a aconseguir resultats analítics fiables en l'anàlisi de plantes. A més, alguns paràmetres de qualitat com la precisió, l'exactitud i els límits de detecció han estat curosament determinats en les diverses configuracions de espectròmetres de XRF utilitzats en el decurs d'aquest treball (EDXRF, WDXRF i EDPXRF) per a establir la capacitat de la tècnica de XRF com a tècnica alternativa a les clàssiques comunament aplicades en la determinació d'elements en mostres vegetals. / The research presented in this thesis is based on the application and improvement of analytical existing methodologies and the development of novel procedures that can be used to assess the environmental effects on metal dispersal around abandoned mining activities. On the one hand, single and sequential extraction procedures were properly applied in order to study the potential mobility, risk and bioavailability of the metals contained in several mining wastes of different features. On the other hand, in an attempt to study the potential sources of the anomalous lead content in vegetation specimens growing on the waste and soils of abandoned mining areas, a methodology based on the use of stable lead isotope ratios using ICP-MS instrumentation was evaluated.Finally, in view of the considerable number of vegetation specimen analysis necessary to assess the impact of mining activities, the study of high productivity analytical methods for metal determination in this kind of matrices was considered appropriate. In this sense, the implementation of suitable quantitative strategies and the recent improvements in the XRF instrumentation have been evaluated to achieve reliable analytical results for plant analysis. Besides, analytical figures of merit such as precision, accuracy and limits of detection have been carefully determined in the diverse configurations of XRF spectrometers employed in the course of this work (EDXRF, WDXRF, EDPXRF) using different excitation sources in order to assess the capability of XRF as an alternative analytical tool to classical destructive methodologies, commonly applied for the determination of elements in vegetation matrices.
|
7 |
Determination of titanium dioxide nanoparticles in personal care products / Determination of titanium dioxide nanoparticles in personal care productsKošík, Juraj January 2016 (has links)
Předkládaná diplomová práce se zabývá extrakcí nanočástic oxidu titaničitého z produktů osobní péče, konkrétně opalovacích krémů a následnou charakterizací těchto částic. Počet komerčně dostupných produktů s obsahem nanočástic TiO2 se neustále zvyšuje a to se sebou přináší potřebu vyhodnotit potenciální osud a nepřímou expozici TiO2 nanošástic o různých velikostí a tvarů a zkoumat jejich celý životní cyklus. Bylo zkoumáno použití ultrafiltrace a ultracentrifugace jako extrakční metody. Dvě metody pro extrakci TiO2 nanočástic byly vyvinuty a aplikovány na vzorky opalovacích krémů. Extrahované částice mohou být použity pro ekotoxikologické studie, případně experimenty v mesokosmu. Velikost částic byla stanovena pomocí metody dynamického rozptylu světla a transmisní elektronové mikroskopie.
|
8 |
Development and Application of IDMS Based Procedure for total Sulphur in Copper Metals and Its AlloysPhukphatthanachai, Pranee 05 April 2019 (has links)
Bei der Schwefelquantifizierung in Kupfer und anderen reinen Metallen zeigte sich in der Vergangenheit eine mangelnde SI-Rückführung und zusätzlich inkonsistente Ergebnisse, wenn verschiedene Methoden verglichen wurden. Um diesen Mangel zu beheben ist ein Referenzverfahren erforderlich, welches SI-rückführbare Werte mit einem zuverlässigen Unsicherheitsbudget ermöglicht. In dieser Studie wurde ein entsprechendes Referenzverfahren zur Quantifizierung von Gesamtschwefel in Kupfer basierend auf der induktiv gekoppelten Plasma-Massenspektrometrie und der Isotopenverdünnungsanalyse (ICP-IDMS) entwickelt.
Um diese Probleme zu lösen wurde mit Hilfe der Ionenaustauschchromatographie ein Schwefel-Matrix-Trennverfahren entwickelt. Dieses Trennverfahren wurde mit ICP-IDMS kombiniert, um Schwierigkeiten mit der Kalibrierung zu lösen und fehlende metrologische Konzepte einzuführen. So wurden die in diesem Projekt erzielten IDMS-Messwerte für die Kalibrierung von GDMS und LA-ICP-MS verwendet, beides Verfahren die im industriellen Einsatz üblich sind. Dadurch konnten mit beiden Routineverfahren zuverlässige Ergebnisse erzeilt warden, die zudem auf SI rückführbar sind.
Darüber hinaus wurde ein auf der LA-ICP-IDMS basierendes Verfahren entwickelt, um den Probenvorbereitungsschritt von ICP-IDMS mit Schwefel-Matrix-Trennung zu reduzieren. Die Vorteile dieser Methode sind ein geringerer Arbeits- und Zeitaufwand, die SI- Rückführung der Messergebnisse und eine für LA-ICP-MS vergleichsweise hohe Genauigkeit. Die Schlüsselrolle hierbei spielte der innovative Einsatz von Polyethylenfritten als Trägermaterial der aufgelösten Probe. Dadurch war die Quantifizierung von Schwefel in Kupferproben mittels LA-ICP-IDMS möglich. Die wesentlichen Parameter wie Absorptionseffizienz der Fritten und Matrixeffekt wurden untersucht. Das entwickelte Verfahren konnte mit Hilfe der ICP-IDMS vollständig validiert werden. / Sulphur quantification in copper and other pure metals in the past revealed a lack of SI-traceability and also showed inconsistent results, when different methods are compared. Therefore, a reference procedure is required to enable SI-traceable measurement results accompanied by a sound uncertainty budget. In this study, such a procedure was developed for the quantification of total sulphur in copper using inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS).
For solving these problems ion exchange chromatography was applied, and a sulphur-matrix separation procedure was developed. This procedure was combined with ICP-IDMS to solve difficulties with the calibration and to realize metrological concepts.
An application of the IDMS procedure was realized by using the measurement results of specific copper samples values for calibrating glow discharge mass spectrometry (GDMS) and laser ablation ICP-MS (LA-ICP-MS). Both techniques are considered routine techniques. Thus, they could provide reliable results which are traceable to the SI.
Additionally, a procedure based on LA-ICP-IDMS was developed to significantly reduce the sample preparation step of ICP-IDMS with sulphur-matrix separation. This procedure is less laborious and the measurement results are still SI traceable and offer a comparatively high accuracy for LA-ICP-MS. Key for this development was the innovative application of polyethylene frits as support material for the dissolved sample. Thus, the quantification of sulphur in copper samples by LA-ICP-IDMS could be realized. The essential parameters are investigated such as the absorption efficiency of the frit and matrix effects. The developed procedure was fully validated by means of the ICP-IDMS results.
|