• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 37
  • 1
  • 1
  • Tagged with
  • 89
  • 47
  • 39
  • 38
  • 37
  • 37
  • 24
  • 24
  • 24
  • 22
  • 20
  • 18
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

The effect of occlusal splint therapy on EMG silent period duration and jaw position an electromyographic and roentgen cephalometric study : a thesis submitted in partial fulfillment ... in occlusion ... /

Davila, Balbina Coromoto. January 1978 (has links)
Thesis (M.S.)--University of Michigan, 1978.
42

Asynchrony of the masticatory muscles in patients with temporomandibular joint pain dysfunction syndrome a thesis submitted in partial fulfillment ... in restorative dentistry, occlusion ... /

Farkhondehpay, Kianoush. January 1976 (has links)
Thesis (M.S.)--University of Michigan, 1976.
43

The effect of occlusal splint therapy on EMG silent period duration and jaw position an electromyographic and roentgen cephalometric study : a thesis submitted in partial fulfillment ... in occlusion ... /

Davila, Balbina Coromoto. January 1978 (has links)
Thesis (M.S.)--University of Michigan, 1978.
44

Condylar position changes coincident with occlusal splint therapy a thesis : ... submitted in partial fulfillment ... restorative dentistry /

Manning, Kieth Earl. January 1989 (has links)
Thesis (M.S.)--University of Michigan, 1989.
45

The effect of occlusal bite splint therapy on temporomandibular joint dysfunction and on mandibular movements as recorded by a pantograph a thesis submitted in partial fulfillment ... restorative dentistry ... /

Roura, Nelson. January 1973 (has links)
Thesis (M.S.)--University of Michigan, 1973.
46

Análise da resistência à flexão e da microdureza de resinas acrílicas utilizadas para confecção de placas interoclusais

Costa, Patrícia dos Santos [UNESP] 18 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-18Bitstream added on 2014-06-13T18:35:13Z : No. of bitstreams: 1 costa_ps_me_araca.pdf: 604141 bytes, checksum: ac2f5eb53a71fc0ba602e7168c63f35c (MD5) / As placas interoclusais podem ser confeccionadas por meio de várias técnicas, sendo a resina acrílica o material de escolha mais difundido atualmente. Devido ao fato de as placas serem submetidas a diferentes tipos de forças por um longoperíodo no interior da cavidade bucal, estas podem fraturar-se ou desgastar-se com facilidade. O objetivo do presente estudo foi avaliar e comparar, por meio de ensaio de resistência à flexão e teste de microdureza Knoop, o comportamento das resinas acrílicas térmica e quimicamente ativadas utilizadas na confecção de placas interoclusais, variando-se as técnicas de confecção e processamento. Para tanto, foram confeccionados 60 espécimes divididos em seis grupos (GI, GII, GIII, GIV, GV, GVI), de acordo com o tipo de resina e técnica de processamento utilizadas. Os grupos GI e GII utilizaram resina acrílica termopolimerizável convencional (Clássico), sendo o GI polimerizado em banho de água quente e o GII pela energia de microondas. Para os grupos GIII, GIV, GV e GVI, utilizou-se resina acrílica autopolimerizável (Jet) e as seguintes técnicas de processamento: GIII) polimerização em condição ambiente (23 l 2oC), GIV) sob pressão de 2kgf/cm2 e água a 40°C, GV) sob a mesma pressão e temperatura a seco e GVI) associação de placa de acetato e polimerização em água a 40°C. Após ensaio de flexão, os dados foram submetidos à análise de variância, complementada pelo teste de Tukey (a = 0,05). Para os valores de microdureza, estes foram submetidos ao teste não paramétrico de Kruskal-Wallis (a = 0,05). Verificou-se que GII e GIII apresentaram, respectivamente, os maiores e menores valores de resistência à flexão em relação aos demais grupos. GI e GII apresentaram valores semelhantes de resistência à flexão (p > 0,05). GIV, V e VI não apresentaram diferença significante entre si (p > 0,05), porém foram estatisticamente superiores ao GIII (p < 0,05). / The occlusal splints can be fabricated by many techniques and the acrylic resin is the main material used for this propose. The splints can be easily facture or worn because they are subjected to different kinds of forces during a long period in the oral cavity. The objective of this study was to evaluate the flexural strength and Knoop microhardness of a conventional heat-polymerized and an autopolymerized acrylic resin used to fabricate occlusal splints, varying the processing laboratorial techniques. Sixty specimens were manufactured and divided in 6 groups (GI, GII, GIII, GIV, GV, GVI) according to the type of the resin and the processing technique used. GI and GII were manufactured with conventional heatpolymerized acrylic resin (Clássico). GI was hot-water-bath polymerized and GII was microwave polymerized. GIII, GIV and GV specimens were fabricated using an autopolymerized acrylic resin (Jet). GIII was polymerized in air condition (23 l 2oC), GIV under 2kgf/cm2 pressure and in water at 40°C, and GV under the same pressure and temperature at dry condition. The GVI specimens were manufactured using autopolymerized acrylic resin and acetate sheet, polymerized in water at 40°C. The resin specimens were broken using a 3-point load on a testing machine. A ANOVA and Tukey test were performed to identify significant differences (a = .05). Knoop microhardness values were analyzed with Kruskal-Wallis test (a = .05). GII and GIII showed, respectively, the highest and the lowest significantly values of strength comparing with the other groups. GI and GII, manufactured with conventional heat-polymerized acrylic resin showed similar strength (p > .05). GIV, V e VI showed similar values between them, however they were stronger than GIII (p < .05). GII showed the highest significantly values of microhardness even when compared to GI.
47

Avaliação comparativa da efetividade das placas oclusais confeccionadas em relação central ou máxima intercuspidação em pacientes com DTM /

Hamata, Marcelo Matida. January 2006 (has links)
Orientador: Paulo Renato Junqueira Zuim / Banca: Alício Rosalino Garcia / Banca: Osvaldo Luiz Bezzon / Resumo: A posição de relação central (RC) para a confecção de placas oclusais é muito discutível. Dessa forma, quando existe estabilidade oclusal, a máxima intercuspidação (MI) poderia ser utilizada como ponto de referência, eliminando a necessidade de registro interoclusal. O presente trabalho tem por objetivo comparar a efetividade de placas oclusais confeccionadas a partir de modelos articulados nessas duas posições. Para isso, 20 pacientes com desordens temporomandibulares (DTM) e dor de origem muscular foram divididos em dois grupos de 10 e tratados com placas confeccionadas nas posições de MI ou RC. Estes foram avaliados por meio de exame clínico, eletrognatográfico e eletromiográfico, antes e após três meses de terapia. Os resultados permitiram verificar que os dois tipos de placa atuaram de forma semelhante. Entretanto, a confecção de placas oclusais a partir da MI mostrou ser uma técnica mais fácil e menos onerosa do que a de RC. / Abstract: Centric relation (CR) position to fabricate occlusal splints is very discussable. In this way, when there is occlusal stability, intercuspal position (IP) could be used as a reference point, eliminating the interocculsal record necessity. The purpose of the present study was to compare the effectiveness of occlusal splints fabricated from models articulated in these two positions. Twenty patients with temporomandibular disorders (TMD) of myogenous origin were divided in two groups with 10 each, which were treated with splints fabricated in the CR or IP. The patients were evaluated by clinical, electrognathographic and electromyographic examinations, before and tree months after the therapy. Results showed similar levels of effectiveness of both kinds of splint. However, the fabrication of the splints from IP technique is easier and less onerous than the CR. / Mestre
48

O uso de placa oclusal no tratamento da disfunção temporomandibular: análise eletromiográfica em 26 pacientes / The using of occlusal splints on temporomandibular dysfunction therapy: electromyography analysis on 26 patients

Kadidja Claudia Maia e Machado 08 April 2009 (has links)
INTRODUÇÃO: O tratamento das disfunções temporomandibulares não segue um padrão aceito na literatura nem na prática clínica. Os efeitos desse tratamento sobre a musculatura mastigatória apresentam-se ainda de maneira não concreta ao profissional. OBJETIVO: Avaliar a atividade eletromiográfica do masséter, direito e esquerdo, em repouso e em contração, além do comportamento elétrico, do músculo em questão, antes e após o uso de placa oclusal, por três meses, em sete momentos. MÉTODOS: Este estudo experimental e prospectivo foi realizado entre setembro de 2006 e junho de 2007. A atividade elétrica foi avaliada através de eletromiografia de superfície em amostra constituída por 26 pacientes, sendo 22 do gênero feminino e 4 do masculino, com disfunção temporomandibular, em sete momentos: antes do uso da placa oclusal, após 7, 14, 21, 30, 60 e 90 dias de uso. Foram comparadas as atividades elétricas entre masséter direito e esquerdo e o comportamento elétrico do músculo nos sete momentos de avaliação, em repouso e em contração. RESULTADOS: Os dados foram analisados estatisticamente. Não houve diferença estatisticamente significante entre as atividades do masséter direito e esquerdo, em repouso (p=0,848) e em contração (p=0,658), durante as avaliações. Nos sete momentos, em repouso, houve diminuição da atividade elétrica do masséter (p=0,000), apresentaram diferenças estatisticamente significantes os momentos 7 e 21 dias (p=0,048); 7 e 30 dias (p=0,005); 7 e 90 dias (p=0,001) e 14 e 90 dias (p=0,032). Em contração, também houve diminuição da atividade eletromiográfica (p=0,000). As diferenças estatisticamente significantes aconteceram entre os momentos: Antes e 7 dias (p=0,017) e Antes e 90 dias (p=0,007). CONCLUSÕES: O uso de placa oclusal não alterou a atividade eletromiográfica entre o masséter direito e esquerdo. O uso de placa oclusal causou diminuição da atividade eletromiográfica em repouso e em contração, nos sete momentos de avaliação. / INTRODUCTION: Temporomandibular dysfunction treatment does not follow an accepted pattern in the literature and at the clinical practice. Treatment effects, on chewing muscles, still present themselves in a non-concrete way to professionals. OBJECTIVES: To analyze right and left masseter electromyographyc activity, as well as their electric behavior, prior to and after the use of occlusal splint for a three-month period in seven different moments. METHODS: This experimental and prospective study has been done between September 2006 and June 2007. The electric activity was evaluated through sample surface electromyography of 26 patients, 22 female genders and 4 male genders with temporomandibular dysfunction in 7 different moments: before the occlusal splint usage and after 7, 14, 21, 30, 60 and 90 days of usage. The electric activity has been compared along the right and left masseter and the muscle electric behavior on the seven evaluation moments, relaxed and under contraction. OUTCOMES: Data has been analyzed statistically. There has not been statistic differences among right and left masseters; relaxed (p=0,848) and contracted (p=0,658), during evaluations. On the seven moments, when relaxed, there was a decrease on the masseter electric activity; statistically significant differences are displayed on the 7 and 21 day-moments (p=0,048); 7 and 30 day-moments (p=0,005); 7 and 90 day-moments (p=0,001) and 14 and 90 day-moments (p=0,032). Under contraction, there has been a decrease on the electromyographyc activity as well (p=0,000). The significant statistically differences took place between the moments: before and 7days (p=0,017) and before and 90 days (p=0,007). CONCLUSIONS: The occlusal splint usage did not alter the electromyographyc activity between right and left masseter. The occlusal splint usage decreasing the electromyographyc activity under contraction and relaxed, on seven moments.
49

Avaliação da eficácia em curto prazo do uso de placas oclusais reposicionadoras e dispositivos NTI (nociceptive trigeminal inhibitory splint) no controle de Artralgia da Articulação Temporomandibular / Short-term evaluation of the efficacy of the use of repositioning occlusal splints and NTI (nociceptive trigeminal inhibitory splint) in the control of Temporomandibular Joint Arthralgy

Ana Sílvia da Mota Corrêa 07 November 2011 (has links)
O objetivo dessa pesquisa foi testar a hipótese de que o tratamento através de aparelhos oclusais (placas oclusais e dispositivo NTI) é benéfico na melhora dos sinais e sintomas de Artralgia da Articulação Temporomandibular (ATM) quando comparado a um grupo controle. Para isso, 60 indivíduos foram avaliados através de questionários e exames que determinaram a presença de Artralgia da ATM e sua intensidade. Essa amostra foi então dividida aleatoriamente em três grupos de 20 indivíduos cada um, sendo que, o primeiro grupo recebeu tratamento com placa reposicionadora rígida em uso parcial e técnicas de aconselhamento e mudanças comportamentais para pacientes com Disfunção Temporomandibular (DTM); o segundo, tratamento com NTI em uso parcial e técnicas de aconselhamento e mudanças comportamentais para pacientes com DTM; e o terceiro grupo, correspondente ao grupo controle, recebeu apenas técnicas de aconselhamento e mudanças comportamentais para pacientes com DTM. As placas foram instaladas e os controles realizados após duas, seis semanas e três meses. Os pacientes foram avaliados através de escala de análise visual de dor, presença de ruídos, abertura bucal ativa, algometria e conforto no uso dos aparelhos oclusais para os grupos experimentais. Os resultados foram analisados através dos testes estatísticos: Teste Kruskal-Wallis, ANOVA e Tukey, adotando nível de significância de 5%. Os três grupos apresentaram melhora nos sinais e sintomas de Artralgia da ATM sugerindo que o tratamento com aparelhos oclusais e técnicas de aconselhamento e mudanças comportamentais parece ser benéfico ao paciente. No entanto, o uso de aparelhos oclusais parece promover uma melhora ao primeiro momento mais rápida, sendo ainda, o uso das placas oclusais e posicionadoras mais confortável ao paciente logo no início do tratamento contribuindo para uma diminuição mais rápida da sua dor. Os dispositivos NTI necessitam de mais estudos em longo prazo para confirmar sua eficácia, assim como a ausência de efeitos adversos. / The aim of this research was to test the hypothesis that the treatment with intraoral appliances (occlusal splints and device NTI) is beneficial to the control of symptoms and signs of arthralgy of temporomandibular joint (TMJ) when compared to a control group. Therefore, sixty patients were analyzed by questionnaires and tests that determined the presence of arthralgy of the TMJ and its intensity. Then this sample was randomly divided into three groups of 20 patients each: the first group was treated with repositioning occlusal splint and orientations; the second group received an anterior device (NTI nociceptive trigeminal inhibitory system), the third group of patients (the control group) just received counseling and orientations for behavioral changes. The devices were installed and used in partial time (only during sleep), and the follow-ups were performed after 2, 6 weeks and 3 months. In these sessions, patients were evaluated according the visual scale of pain (VAS), presence of noise, active mouth opening, temporomandibular joint algometry and comfort in the use of intraoral appliances for the experimental groups. The results were analyzed with Kruskal-Wallis, ANOVA and Tukey, adopting a significance level of 5%. All three groups showed improvement in signs and symptoms of temporomandibular joint arthralgy, suggesting that occlusal appliances and behavioural orientations may be beneficial in the treatment of this condition. However, the management with occlusal appliance and orientations seems to have an earlier effect. The use of occlusal repositioning splint is more comfortable at the beginning of the treatment of patients contributing to a faster reduction of their pain. Long - term studies with the NTI device are needed to establish its effectiveness and absence of adverse dental effects.
50

Efeito sobre o sono na utilização de uma placa oclusal miorrelaxante em pacientes com apneia obstrutiva do sono / Sleep effects on the use of stabilization occlusal splints in patients with obstructive sleep apnea

Thiago Carôso Fróes 18 May 2015 (has links)
A utilização de placas oclusais estabilizadoras para controle do Bruxismo do Sono (BS) é uma prática muito comum entre os odontólogos, no entanto, muitos profissionais fazem uso desta medida terapêutica sem avaliar a possibilidade do paciente ter, ou vir a desenvolver, outro distúrbio do sono associado, como a Síndrome da Apneia Obstrutiva do Sono (SAOS). Esta síndrome compromete a qualidade de vida pois aumenta o risco para doença cardiovascular assim como o risco para acidentes automotivos. Além disso, estudos sugerem que a utilização de placas oclusais poderia agravar o quadro da SAOS, uma vez que favoreceria à retrusão mandibular com consequente diminuição do espaço para a língua. Como a literatura ainda é inconclusiva e o questionamento clínico permanece, o objetivo do estudo foi avaliar os efeitos da utilização de uma placa miorrelaxante por, no mínimo, 2 meses sobre o sono de 11 pacientes com SAOS. Para tanto, foram aplicados questionários como o da Escala de Sonolência de Epworth (ESE) e o Índice de qualidade do sono de Pittsburgh (IQSP), também foram realizadas polissonografias (PSG) antes, e durante, a utilização da placa. A média de idade desses pacientes foi de 47 anos (mín 33/ máx 61) sendo que 63.6% era do gênero masculino. Os resultados dos questionários não revelaram diferença significante para os dois momentos da análise. No entanto, os dados polissonográficos evidenciaram aumento no Índice de Apneia e hipopneia (16,6-28,32 eventos por hora, p=0,003) e no Índice de Distúrbios Respiratórios (20,14-33,96 eventos por hora, p=0,003) quando da utilização da placa. Foi observado, também, uma dessaturação da oxiemoglobina mínima (85,55-79,36, p=0,026) e um aumento do tempo de saturação abaixo de 90% medido em minutos (1,43-3,98; p= 0,025). Foi possível concluir que a utilização da placa miorrelaxante, por um período de 2 meses, em pacientes portadores da SAOS, pode estar associada ao agravamento deste distúrbio. / The use of stabilization occlusal splints for Sleep Bruxism (SB) control is a very common practice among Dentists. However many professionals use this therapy without evaluating the possibility of their patients having, or developing other associated sleep disorders, such as Obstructive Sleep Apnea (OSA). This syndrome affects the quality of life, increases the risk of cardiovascular disease as well as traffic accidents. In addition, studies suggest that the use of occlusal splints may make OSA worse, once mandibular retrusion and decrease of tongue space may occur. Since literature is inconclusive and the clinical question remains, the objective of this study was to evaluate the effects over sleep of 11 OSA patients when using an occlusal stabilization splint for at least 2 months. Therefore, questionnaires such as Epworth Sleepiness Scale (ESS) and the Pittsburgh Sleep Quality Index (PSQI), in addition to polysomnography (PSG) were performed before, and during, splints use. Patients\' average age was 47 years old (33±61) and 63.6% were male. The questionnaire results revealed no significant difference for the two stages of analysis. However, polysomnographic data showed an increase in the apnea-hypopnea index (16.6 to 28.32 events per hour, p = 0.003) and respiratory disorders Index (20.14 to 33.96 events per hour, p = 0.003) when patients were using the occlusal splints. It was also observed a decrease of minimum oxyhemoglobin desaturation (85.55 to 79.36, P = 0.026) and an increase in saturation time below 90%, measured in minutes (from 1.43 to 3.98; p = 0.025). It was concluded that the use of occlusal splints for a period of 2 months in patients with OSA may be associated to aggravation of such disorder.

Page generated in 0.0395 seconds