• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de amostras padrão de referência para difratometria / Development of standart reference samples for diffractometry

Galvao, Antonio de Sant'Ana 05 May 2011 (has links)
Neste trabalho foram desenvolvidas amostras de materiais padrão de referência para difratometria de policristais. Materiais de alta pureza foram tratados mecânica e termicamente até atingirem as características necessárias para serem usados como materiais padrão de referência de alta qualidade, comparáveis àqueles produzidos pelo NIST. As medidas foram feitas inicialmente em vários difratômetros convencionais de laboratório de difração de raios X, com geometria de Bragg -Brentano, difratômetros de nêutrons e, posteriormente, em equipamento de alta resolução com fonte síncrotron. Os parâmetros de rede obtidos foram calculados pelo programa Origin e ajustados pelo Método dos Mínimos Quadrados. Esses ajustes foram comparados com os obtidos pelo Método de Rietveld, usando o programa GSAS através da interface gráfica EXPGUI, mostrando-se bastante satisfatórios. Os materiais obtidos foram alumina-α, ítria, silício, céria, hexaboreto de lantânio e fluoreto de lítio, que apresentaram qualidade semelhante e, em alguns casos, superiores aos padrões desenvolvidos e comercializados pelo NIST, a custos bem menores. / In this work, samples of standard reference materials for diffractometry of polycrystals were developed. High-purity materials were submitted to mechanical and thermal treatments in order to present the adequate properties to be used as high-quality standard reference materials for powder diffraction, comparable to the internationally recognized produced by the USA National Institute of Standards and Technology NIST, but at lower costs. The characterization of the standard materials was performed by measurements in conventional X-ray diffraction diffractometers, high resolution neutron diffraction and high-resolution synchrotron diffraction. The lattice parameters were calculated by extrapolation of the values obtained from each X-ray reflection against cos2θ by the Least-Squares Method. The adjustments were compared to the values obtained by the Rietveld Method, using the program GSAS. The materials thus obtained were the α-alumina, yttrium oxide, silicon, cerium oxide, lanthanum hexaboride and lithium fluoride. The standard reference materials produced present quality similar or, in some cases, superior to the standard reference materials produced and commercialized by the NIST.
2

Preparação e caracterização de casearinas de Casearia sylvestris como padrão fitoquímico

Passareli, Fernando [UNESP] 05 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-05Bitstream added on 2014-06-13T20:38:27Z : No. of bitstreams: 1 passareli_f_me_araiq.pdf: 8997721 bytes, checksum: a69e7054a6bba5e85800139250ac1c79 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Tendo em vista o pequeno acervo de padrões de referência disponíveis para uso no controle de qualidade de fitoterápicos preparados a partir de espécies nativas brasileiras, este trabalho tem como objetivos preparar e caracterizar padrões de alta pureza de casearinas a partir de Casearia sylvestris, uma planta nativa da flora brasileira, que há muito tempo vem sendo usada pela população. A estratégia utilizada para o isolamento das casearinas consistiu no fracionamento do extrato etanólico das folhas por extração em fase sólida utilizando sílica e carvão ativo, cromatografia em coluna em fase normal, além de desenvolvimento de método em CLAE preparativo em fase reversa no modo isocrático e reciclante. Para as análises por CLAE preparativo no modo isocrático, inicialmente, alguns parâmetros como resolução, carga e volume de injeção foram otimizados em coluna analítica e posteriormente foi feita a transferência de escala para coluna preparativa utilizando fator de escalonamento de 21,2. A transferência foi adequada, resultando no isolamento de 10,5 mg da casearina J, 30,0 mg da casearina X e 3,0 mg da casearina Z. Em modo reciclante, foram isolados 60,0 mg da caseargrewiina F. As análises de pureza dessas substâncias foram feitas através de CLAE- DAD, calculando-se primeiramente a pureza de pico, que foi de 100% para as três casearinas analisadas e, posteriormente, a pureza cromatográfica, pelo método de normalização de área, sendo de 85,5, 97,2, e 98,6% para as casearinas J, X e caseargrewiina F, respectivamente. As análises por CLAE-DAD-EM foram importantes para confirmar o resultado de pureza de pico, assim como para obter os dados de massas dos contaminantes presentes nessas amostras. O grau de pureza por DSC não pôde ser obtido, devido à ausência do pico referente à fusão das casearinas, inferindo que as substâncias... / Taking into account the few library of reference standards available for the use in quality control of phytotherapic agents from Brazilian native species, the aim of this work was to prepare and characterize high purity standards of casearins from Casearia sylvestris, a native plant of the Brazilian flora that has been used traditionally by population for a long time as remedy. The strategy to isolate the casearins was to fraction at the ethanolic extract from leaves by solid phase extraction using silica and active charcoal, column chromatography (normal phase) and, additionally, the method development in preparative HPLC (reverse phase) using isocratic e recycling mode. For the analyses by preparative HPLC using isocratic mode, firstly of all some parameters like resolution, amount of sample and volume injection were optimized in analytical column and then the scale-up to preparative column was carried out using a scale factor of 21.2. The scale-up was appropriate, leading to the isolation of 10.5 mg of the casearin J, 30.0 mg of the casearin X and 3.0 mg of the casearin Z. In recycling mode, 60.0 mg of the caseargrewiin F were isolated. The purity analyses of these substances were carried out by HPLC-DAD, firstly measuring the peak purity, wich was 100.0% for the three analyzed casearins, and then, the chromatographic purity, by the area normalization method, wich was 85.5, 97.2 and 98.6% for the casearins J, X and caseargrewiin F, respectively. The HPLC-DAD-MS analyses were important to confirm the peak purity results as well as to obtain the mass data of contaminants wich are usually present in these samples. The measurement of the purity degree by DSC method was not possible due to the absence of fusion peak, thus it suggests an amorphous state for these substances. From the TG/DTG/DTA curves, it was possible to suggest the absence of volatile... ((Complete abstract click electronic access below)
3

Preparação e caracterização de casearinas de Casearia sylvestris como padrão fitoquímico /

Passareli, Fernando. January 2010 (has links)
Orientador: Alberto José Cavalheiro / Banca: Fernando Batista da Costa / Banca: João Carlos Palazzo de Mello / Resumo: Tendo em vista o pequeno acervo de padrões de referência disponíveis para uso no controle de qualidade de fitoterápicos preparados a partir de espécies nativas brasileiras, este trabalho tem como objetivos preparar e caracterizar padrões de alta pureza de casearinas a partir de Casearia sylvestris, uma planta nativa da flora brasileira, que há muito tempo vem sendo usada pela população. A estratégia utilizada para o isolamento das casearinas consistiu no fracionamento do extrato etanólico das folhas por extração em fase sólida utilizando sílica e carvão ativo, cromatografia em coluna em fase normal, além de desenvolvimento de método em CLAE preparativo em fase reversa no modo isocrático e reciclante. Para as análises por CLAE preparativo no modo isocrático, inicialmente, alguns parâmetros como resolução, carga e volume de injeção foram otimizados em coluna analítica e posteriormente foi feita a transferência de escala para coluna preparativa utilizando fator de escalonamento de 21,2. A transferência foi adequada, resultando no isolamento de 10,5 mg da casearina J, 30,0 mg da casearina X e 3,0 mg da casearina Z. Em modo reciclante, foram isolados 60,0 mg da caseargrewiina F. As análises de pureza dessas substâncias foram feitas através de CLAE- DAD, calculando-se primeiramente a pureza de pico, que foi de 100% para as três casearinas analisadas e, posteriormente, a pureza cromatográfica, pelo método de normalização de área, sendo de 85,5, 97,2, e 98,6% para as casearinas J, X e caseargrewiina F, respectivamente. As análises por CLAE-DAD-EM foram importantes para confirmar o resultado de pureza de pico, assim como para obter os dados de massas dos contaminantes presentes nessas amostras. O grau de pureza por DSC não pôde ser obtido, devido à ausência do pico referente à fusão das casearinas, inferindo que as substâncias... (resumo completo, clicar acesso eletrônico abaixo) / Abstract: Taking into account the few library of reference standards available for the use in quality control of phytotherapic agents from Brazilian native species, the aim of this work was to prepare and characterize high purity standards of casearins from Casearia sylvestris, a native plant of the Brazilian flora that has been used traditionally by population for a long time as remedy. The strategy to isolate the casearins was to fraction at the ethanolic extract from leaves by solid phase extraction using silica and active charcoal, column chromatography (normal phase) and, additionally, the method development in preparative HPLC (reverse phase) using isocratic e recycling mode. For the analyses by preparative HPLC using isocratic mode, firstly of all some parameters like resolution, amount of sample and volume injection were optimized in analytical column and then the scale-up to preparative column was carried out using a scale factor of 21.2. The scale-up was appropriate, leading to the isolation of 10.5 mg of the casearin J, 30.0 mg of the casearin X and 3.0 mg of the casearin Z. In recycling mode, 60.0 mg of the caseargrewiin F were isolated. The purity analyses of these substances were carried out by HPLC-DAD, firstly measuring the peak purity, wich was 100.0% for the three analyzed casearins, and then, the chromatographic purity, by the area normalization method, wich was 85.5, 97.2 and 98.6% for the casearins J, X and caseargrewiin F, respectively. The HPLC-DAD-MS analyses were important to confirm the peak purity results as well as to obtain the mass data of contaminants wich are usually present in these samples. The measurement of the purity degree by DSC method was not possible due to the absence of fusion peak, thus it suggests an amorphous state for these substances. From the TG/DTG/DTA curves, it was possible to suggest the absence of volatile... ((Complete abstract click electronic access below) / Mestre
4

SÃntese do padrÃo difratomÃtrico de Ãxido de CÃrio para determinaÃÃo da largura instrumental / Synthesis of diffraction standard of cerium oxide for determination of the instrumental broadening

Anderson MÃrcio de Lima Batista 19 July 2013 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Com uso da difraÃÃo de raios X por pÃ, à possÃvel determinar parÃmetros fÃsicos de uma rede cristalina e atà quantificar suas fases. Alguns desses parÃmetros sÃo: as dimensÃes da cÃlula unitÃria (parÃmetros de rede), seu volume, tamanho de cristal, microdeformaÃÃo e etc. Contudo, à preciso ser cauteloso com a preparaÃÃo da amostra e com o alinhamento do difratÃmetro para que os parÃmetros obtidos pela medida sejam confiÃveis. Para que os erros sistemÃticos nÃo afetem os valores desses parÃmetros, utilizam-se materiais padrÃes que sÃo denominados SRM - Standard Reference Materials (Material PadrÃo de ReferÃncia). Em qualquer medida de difraÃÃo de raios-X, o difratograma obtido de uma amostra a ser analisada apresenta efeitos externos, que podem ser, por exemplo, a forma como foi preparada a amostra ou provocado pelo prÃprio equipamento. Levando em conta que os efeitos instrumentais (sistemÃticos) sempre estarÃo presentes numa medida, entÃo, a questÃo à saber quantificar esse efeito. O SRM escolhido para esse propÃsito à o Ãxido de cÃrio (CeO_2) obtido a partir de sulfato de cÃrio tetrahidratado (Ce〖(SO_4)〗_2∙4H_2 O) adquirido da Sigma-Aldrich. As principais caracterÃsticas do SRM sÃo: cristais com dimensÃes da ordem de μm, quimicamente inerte, homogÃneo, baixa microdeformaÃÃo e os picos de difraÃÃo sejam estreitos e intensos. Todas essas condiÃÃes sÃo essenciais, especialmente o tamanho dos cristais, para determinar a chamada largura instrumental. Segundo a equaÃÃo de Scherrer, a largura a meia altura (FWHM) de um pico de difraÃÃo à inversamente proporcional ao tamanho mÃdio dos cristais, ou seja, medidas feitas em cristais espessos, homogÃneos e de baixa microdeformaÃÃo produzirà picos estreitos, e consequentemente, a largura e perfis dos picos de difraÃÃo estÃo associados a efeitos instrumentais (por exemplo: divergÃncia, fendas, dispersÃo espectral e etc.). O objetivo deste trabalho consiste em sintetizar o CeO_2 com as condiÃÃes apresentadas anteriormente para que seja possÃvel, atravÃs de auxÃlio computacional, determinar a largura instrumental do difratÃmetro. Segundo os resultados apresentados pelo o autor do presente trabalho, verifica-se que o Ãxido de cÃrio sintetizado pode ser utilizado como material padrÃo de referÃncia para difratometria. / With the use of X-ray powder diffraction, it is possible to determine physical parameters of a crystal lattice and quantify its phases. Some of these parameters are: the dimensions of unit cell (lattice parameters), volume, crystal size, microstrain, etc. However, it is necessary to be cautious with sample preparation as well as with the diffractometer alignment in order to obtain reliable parameters. For the systematic errors do not affect the values of these parameters, patterns samples are used which are denominated Standard Reference MaterialsÂ-SRM. In X-ray powder diffraction measurement, the patterns obtained from a sample has external effects, such as the way of preparing sample or effects caused by the equipment itself. Taking into account the instrumental effects (systematic), which will always be present in a measurement, thus, the challenge is how to quantify this effect. The SRM selected for this purpose is cerium oxide (CeO_2) which were obtained from cerium sulfate tetrahydrate (Ce〖(SO_4)〗_2∙4H_2 O) purchased from Sigma-Aldrich. The major features of SRM are: crystals have dimensions on the order of Âm, chemically inert, homogeneous, low microstrain, narrow and intense diffraction peaks. All these conditions are essential, especially the crystal size to determine the instrumental width. According to the Scherrer equation, the full width at half maximum (FWHM) of a diffraction peak is inversely proportional to the average size of the crystals, in other words, measurements made in thick crystals, homogeneous, low microstrain will produce narrow peaks, and consequently, the total width and profile of the diffraction peaks are associated with instrumental effects (for example: divergence, lenses, spectral dispersion, etc). The objective of this work is to synthesize CeO_2 with the conditions described earlier and to determine the instrumental width of the diffractometer. According to the results presented by the authors of this work, it was observed that cerium oxide can be used as Standard Reference Materials for X-ray Diffraction analysis.
5

Desenvolvimento de amostras padrão de referência para difratometria / Development of standart reference samples for diffractometry

Antonio de Sant'Ana Galvao 05 May 2011 (has links)
Neste trabalho foram desenvolvidas amostras de materiais padrão de referência para difratometria de policristais. Materiais de alta pureza foram tratados mecânica e termicamente até atingirem as características necessárias para serem usados como materiais padrão de referência de alta qualidade, comparáveis àqueles produzidos pelo NIST. As medidas foram feitas inicialmente em vários difratômetros convencionais de laboratório de difração de raios X, com geometria de Bragg -Brentano, difratômetros de nêutrons e, posteriormente, em equipamento de alta resolução com fonte síncrotron. Os parâmetros de rede obtidos foram calculados pelo programa Origin e ajustados pelo Método dos Mínimos Quadrados. Esses ajustes foram comparados com os obtidos pelo Método de Rietveld, usando o programa GSAS através da interface gráfica EXPGUI, mostrando-se bastante satisfatórios. Os materiais obtidos foram alumina-α, ítria, silício, céria, hexaboreto de lantânio e fluoreto de lítio, que apresentaram qualidade semelhante e, em alguns casos, superiores aos padrões desenvolvidos e comercializados pelo NIST, a custos bem menores. / In this work, samples of standard reference materials for diffractometry of polycrystals were developed. High-purity materials were submitted to mechanical and thermal treatments in order to present the adequate properties to be used as high-quality standard reference materials for powder diffraction, comparable to the internationally recognized produced by the USA National Institute of Standards and Technology NIST, but at lower costs. The characterization of the standard materials was performed by measurements in conventional X-ray diffraction diffractometers, high resolution neutron diffraction and high-resolution synchrotron diffraction. The lattice parameters were calculated by extrapolation of the values obtained from each X-ray reflection against cos2θ by the Least-Squares Method. The adjustments were compared to the values obtained by the Rietveld Method, using the program GSAS. The materials thus obtained were the α-alumina, yttrium oxide, silicon, cerium oxide, lanthanum hexaboride and lithium fluoride. The standard reference materials produced present quality similar or, in some cases, superior to the standard reference materials produced and commercialized by the NIST.
6

Comparison of Urinary PAHs among Firefighters and Asphalt Pavers

Aquino, Theodore 23 March 2016 (has links)
Firefighters and asphalt pavers are exposed to polycyclic aromatic hydrocarbons (PAHs) during various work activities. The purpose of this study was to evaluate urinary PAH levels and compare these bio-monitoring levels among firefighters, asphalt pavers, and non-occupationally exposed individuals. The National Institute of Standards and Technology (NIST) urinary PAH levels were used for non-occupationally exposed controls. When compared to the NIST standard for smokers and non-smokers, firefighters demonstrated statistically significant differences in urinary concentration differences for the following metabolites: 2-OH-fluorene, 3-OH-fluorene and 1-OH-pyrene, which were lower in firefighters than the NIST mean for smokers. 1-OH-phenanthrene, 2-OH-phenanthrene and 3-OH-phenanthrene were higher among world trade center exposed firefighters than the NIST mean for smokers. When firefighters were compared to the NIST non-smoker standard, firefighters demonstrated elevated levels in all tested PAH biomarkers due to a mixture of smokers and non-smokers in the firefighter cohort. Asphalt workers had statistically significant higher urinary concentration elevations in 2-OH-fluorene, 1-OH-phenanthrene and 3-OH-phenanthrene as compared to the NIST smoker mean. When asphalt pavers were compared to the NIST non-smoker mean, asphalt pavers had statistically significant increases in all tested PAH biomarkers, with the exception of 2-OH-phenanthrene. While firefighters did not demonstrate a substantial change in urinary PAH metabolite levels compared to control populations of smokers and non-smokers, asphalt pavers experienced concentrations that were in some cases increased by orders of magnitude compared to NIST controls. Future research may be needed to evaluate any potential health risk posted to occupational exposed asphalt pavers.

Page generated in 0.0881 seconds