• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 71
  • 11
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 115
  • 115
  • 17
  • 12
  • 12
  • 11
  • 11
  • 11
  • 11
  • 11
  • 9
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

A study of stainless steel coil spring pressures a thesis submitted in partial fulfillment ... orthodontics /

Rabinowitz, Seymour A. January 1900 (has links)
Thesis (M.S.)--University of Michigan, 1941.
102

Determination of wall thickness and height limits when cutting various materials with wire electric discharge machining processes /

Kim, Sangseop, January 2005 (has links) (PDF)
Thesis (M.S.)--Brigham Young University. School of Technology, 2005. / Includes bibliographical references (p. 77-79).
103

Efeito da adição de boro na microestrutura, dureza, resistência à oxidação e ao desgaste do aço inoxidável austenítico 316L sinterizado.

Peruzzo, Marcele 26 February 2016 (has links)
Este trabalho analisa o efeito da adição de boro ao aço inoxidável austenítico 316L como um aditivo da sinterização no processo de metalurgia do pó. O efeito do B foi investigado em termos da densificação, microestrutura, dureza, resistência à oxidação e ao desgaste. Os pós de 316L foram misturados com 0,6% e 0,8% em massa de boro, compactados unixialmente a 800 MPa e sinterizados em atmosfera de argônio, a uma taxa de 10°C.min-1 na temperatura de 1240°C durante 30 min. A microestrutura e as fases cristalinas das amostras sinterizadas foram avaliadas por microscopia ótica, microscopia eletrônica de varredura por emissão de campo (MEV-FEG), espectroscopia de raios X por dispersão de energia (EDS) e difração de raios X (DRX) utilizando o método de refinamento Rietveld. A técnica de calorimetria diferencial exploratória (DSC) foi realizada para estudar o comportamento das amostras de 316L com e sem adição de boro, nos estados sólido e líquido. A macrodureza das amostras sinterizadas foi medida na escala Vickers e a microdureza das fases formadas foi medida por meio de ensaios de indentação instrumentada. A composição química dos óxidos formados nas amostras de 316L com e sem adição de boro após os ensaios de oxidação cíclica nas temperaturas de 800°C, 900°C e 1000°C foram determinados por EDS e DRX. O coeficiente de atrito e o coeficiente de desgaste específico das amostras sinterizadas foram determinados por meio do ensaio de deslizamento alternado e os mecanismos de desgastes foram investigados por meio das técnicas de MEV-FEG e EDS. A adição de boro no 316L resulta em uma reação eutética entre o boro e a matriz austenítica do 316L. Os resultados de EDS e DRX revelaram a formação de dois boretos do tipo M2B ricos em Fe, Cr e Mo, (Fe,Cr)2B e (Cr,Mo)2B, provenientes da reação eutética, os quais se concentraram principalmente no contorno dos grãos austeníticos. A formação dos boretos do tipo M2B favoreceu a densificação, através da fase líquida formada durante a sinterização e promoveu o aumento da dureza, da resistência à oxidação e ao desgaste do aço inoxidável austenítico 316L. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES / This work analyses boron additions to AISI 316L austenitic stainless steels, as a sintering additive in the powder metallurgy process. The effect of boron addition was investigated in terms of densification, microstructure, hardness, oxidation resistance and wear behavior. Samples were prepared with 0.6 wt.% and 0.8 wt.% of boron, pressed to 800 MPa and sintered under argon atmosphere. Sintering cycle involved heating up to the sintering temperature of 1240°C, at a rate of 10°C.min-1, holding at this peak temperature for 30 min. Microstructure of the sintered bodies was examined by field emission scanning electron microscopy (FESEM), energy dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD), using Rietveld refinement. Differential scanning calorimetry (DSC) was used to study the behavior of both the free and boron-containing 316L samples at solid and liquid states. The Vickers hardness of sintered samples was assessed. Microhardness was evaluated using instrumented indentation. The oxide chemical composition of 316L without and containing boron samples, after cyclic oxidation at 800°C, 900°C and 100°C, was determined by EDS and XRD. The friction coefficients and specific wear coefficient of sintered samples were determined by reciprocating sliding and the wear mechanisms by FESEM and EDS. Boron addition to AISI 316L steel resulted in an eutectic reaction between the austenitic matrix and boron. EDS and XRD results revealed the formation of (Fe,Cr)2B and (Cr,Mo)2B borides, from eutectic reaction, which were concentrated mainly in intergranular sites. The formation of M2B borides favored material densification through the development of a liquid phase during sintering, and promoted an increase in hardness, oxidation and wear resistance of AISI 316L steel.
104

Die strukturele gebruik van warmgewalsde tipe 3CR12 vlekvrye staal

Bosch, Hans Hendrik 05 June 2014 (has links)
M.Ing. (Civil Engineering) / The purpose of this investigation was to develop the basic information necessary for formulating creteria for the design of Type 3CR12 steel hot-rolled sections as columns. The mechanical properties needed for structural design are established. Investigations into the behaviour of axially loaded compression members indicated that the overall column buckling of compression members may be predicted with confidence by the tangent modulus approach. Finally simplified design recommendations are made for the design of Type 3CR12 steel hot-rolled columns. The need for future research are identified.
105

Welding of high strength and stainless steels : a study on weld metal strength and stress relieving

Agapakis, John January 1982 (has links)
Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Ocean Engineering; and, (M.S.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 1982. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ENGINEERING / Includes bibliographical references. / by John Emmanuel Agapakis. / M.S.
106

Influência do nitrogênio adicionado por SHTPN na resistência à erosão por cavitação do aço inoxidável martensítico

Maftoum, Ricardo de Almeida 22 April 2012 (has links)
Muitos estudos são realizados para melhorar a resistência à erosão por cavitação dos aços. Entre estes estudos, está a utilização de aços inoxidáveis enriquecidos com nitrogênio na superfície. O presente trabalho estudou o uso da técnica SHTPN (Solution Heat Treatment after Plasma Nitriding), que consiste em duas etapas. Primeiro utiliza-se a nitretação a plasma, para inserir o nitrogênio no material. Na sequência realiza-se o tratamento térmico de solubilização, para que o nitrogênio fique em solução sólida. Foram utilizados neste trabalho dois aços inoxidáveis martensíticos (ASTM CA-6NM e ASM 15-5PH). A nitretação foi realizada na temperatura de 630°C por 3 horas. Para o aço CA-6NM foram utilizadas três diferentes condições de solubilização (1100°C por 1 hora, NS1, 1200°C por 30 minutos, NS2 e 1200°C por 1 hora NS3). Para o aço 15-5PH foi utilizada apenas 1 condição de solubilização (1200°C por 30 minutos, NS), e realizado posterior tratamento de envelhecimento (390°C por 8 horas, NSE). As amostras foram analisadas por difração de raios-x, microscopia ótica e determinação de perfil de microdureza na secção transversal. Verificou-se um aumento da dureza superficial dos aços CA-6NM, porém não foi observado grande presença de austenita próxima à superfície. No aço 15-5PH, foi observada uma camada de austenita na superfície. O ensaio de cavitação foi realizado conforme norma ASTM G32/09, porém utilizando o método indireto. A região cavitada das amostras foi caracterizada por microscopia eletrônica de varredura. Constatou-se que as amostras tratadas obtiveram aumento de resistência à erosão por cavitação, sendo de mais de 5 vezes para a condição NS1 e de três vezes para a condição NSE. / Several studies are being done to improve the cavitation erosion resistance of steel. Among those studies, is the use of steels with nitrogen enriched surfaces. In this study the use of SHTPN (Solution Heat Treatment after Plasma Nitriding) technique was studied, which consists in performing plasma nitriding, used to add nitrogen to the material, followed by a solubilization treatment so that the nitrogen is in solid solution. On this experiment two martensitic stainless steel were used (ASTM CA-6NM and ASM 15-5PH). Nitriding was performed at 630°C for 3 hours. Three different solubilization conditions were used for CA6NM steel (1100°C for 1 hour, NS1, 1200°C for 30 minutes, NS2 and 1200° for 1 hour, NS3). Only one condition was used for 15-5PH steel (1200°C por 30 minutos, NS), and later used an aging treatment (390°C for 8 hours, NSE). The samples were analyzed through x-ray diffraction, optical microscopy and microhardness profiles. All CA6NM samples had an increase in surface hardness, and no big austenite presence was observed. On 15-5PH steel, an austenictic phase was observed. The cavitation test was conducted according to ASTM G32/09 standard, but using the indirect method. The damaged area of the samples was analyzed by scanning electron microscopy. The treatment increased cavitation erosion resistance of all samples, having increased over 5 times for the NS1 sample and 3 times for NSE sample.
107

Fretting behavior of AISI 301 stainless steel sheet in full hard condition

Hirsch, Michael Robert 10 July 2008 (has links)
Fretting, which can occur when two bodies in contact undergo a low amplitude relative slip, can drastically reduce the fatigue performance of a material. The extent of fretting damage is dependent on the material combination and is affected by many parameters, making it difficult to design against fretting. Some of these parameters include contact force, displacement amplitude, and contacting materials. This work develops a method for quantifying the extent of damage from fretting as a function of these parameters for a thin sheet of AISI 301 stainless steel in the full hard condition in contact with both ANSI A356 aluminum and AISI 52100 steel contacting bodies. Fretting experiments were conducted on a Phoenix Tribology DN55 Fretting Machine using a fixture which was developed for holding thin specimens. The displacement amplitude and normal force were systematically varied in order to cover a range that could typically be experienced during service. The tribological behavior was studied by analyzing friction force during cycling and inspecting the resulting surface characteristics. Fretting damaged specimens were cycled in tension in a servohydraulic test system to failure. The decrease in fatigue life caused by fretting damage was determined by comparing the stress-life (S-N) response of the fretted specimens to the S-N response of the virgin material, thus characterizing the severity of the fretting damage. The conditions that lead to the greatest reduction in life were identified in this way. Using the fracture mechanics based NASGRO model, an Equivalent Initial Flaw Size (EIFS) was used to quantify the level of fretting damage, thus separating the life of the component into crack nucleation and subsequent propagation. This method and data will allow engineers to design more robust components that resist fretting damage, thus increasing the safety and reliability of the system.
108

Resistência a corrosão da camada martensitica formada na superfície do aço inoxidável ferrítico 409 tratado por SHTPN

Assumpção, Roberto Luís de 29 May 2013 (has links)
CNPq / Os aços inoxidáveis são amplamente utilizados nas indústrias químicas, petroquímicas, nucleares, de geração de energia, biomédica e de processamento de alimentos. Em geral os aços inoxidáveis apresentam boa resistência à corrosão, entretanto a aplicabilidade destes aços pode ser restringida pela dureza ou pela resistência a corrosão. Usualmente os aços de alta resistência e dureza apresentam elevados teores de carbono, apresentando uma estrutura martensítica, com consequente redução da resistência à corrosão. Por outro lado os aços com maior resistência a corrosão apresentam menor dureza e consequente menor resistência ao desgaste. Diversas soluções têm sido implementadas no sentido de melhorar a resistência a corrosão e ao desgaste simultaneamente desses materiais. Dentre estas a adição de nitrogênio na superfície através da nitretação a plasma, implantação iônica, tratamento térmico de solubilização após nitretação a plasma (SHTPN – Solution Heat Treatment after Plasma Nitriding). Este trabalho tem como objetivo determinar os parâmetros de SHTPN que possibilite obter martensita de nitrogênio na superfície do aço AISI 409, bem como, a avaliação de sua resistência à corrosão. Foi possível verificar uma melhora na resistência à corrosão das condições tratadas por SHTPN, assim como um aumento na resistência mecânica, avaliado pelo perfil de dureza da camada superficial tratada. / Stainless steels are widely used on chemical, petrochemical, nuclear, energy generation, biomedical and food processing industries. In general, stainless steels present good corrosion resistance. However, the application of these materials can be restrained by the hardness and the corrosion resistance. Usually, high strength steels present high carbon content and martensitic structure, what can consequently cause a reduction on corrosion resistance. On the other hand, high corrosion resistance steels present low hardness and weak wear properties. Thereby, many solutions have been made to improve simultaneously wear properties and corrosion resistance of these materials, specially related to the introduction of nitrogen on the surface, through plasma nitriding, ion implantation and SHTPN (Solution Heat Treatment after Plasma Nitriding) processes. The aim of this paper is to determine SHTPN parameters that can form nitrogen martensite on the surface of AISI 409 stailess steel, as well as the evaluation of its corrosion resistance. It was verified an improve on corrosion resistance conditions of SHTPN treated samples. Aditionally, there was an improve on mechanical resistance showed by hardness profiles.
109

Efeito da nitretação por plasma na dureza e na resistência à corrosão do aço inoxidável cirúrgico ASTM 420F

Fiorani, Silviane Caroline 30 January 2012 (has links)
Os aços inoxidáveis martensíticos são amplamente utilizados em aplicações biomédicas devido a sua excelente resistência a corrosão e boas propriedades mecânicas. Entretanto, em aplicações como brocas para a implantodontia, seu desempenho é insatisfatório. Nesta aplicação usualmente utiliza-se de revestimentos como DLC para melhorar a resistência a corrosão, a resistência ao desgaste, bem como, diminuir o coeficiente de atrito broca-osso. Diversos trabalhos na literatura mostram que a nitretação a baixas temperaturas produz camadas superficiais de alta dureza e alta resistência à corrosão. Sabe-se também que o aumento da dureza do substrato melhora o suporte para a adesão do revestimento como o DLC. Estes tratamentos são conhecidos como duplex. Neste trabalho estudou-se o efeito da nitretação a baixa temperatura na resistência à corrosão e dureza de aços inoxidáveis martensiticos do tipo ASTM 420F, bem como, a influência na dureza e resistência à corrosão do tratamento duplex nitretação e DLC. Foram escolhidos cinco parâmetros de nitretação a baixa temperatura, em tempos diferentes para avaliar o comportamento na dureza e resistência à corrosão. O parâmetro que teve o melhor desempenho, atingindo maior dureza e proporcionando uma melhor resistência à corrosão entre os demais, foi a 380°C por 6 horas. Nessa condição, a dureza média de topo foi de 894 HV (1Kgf) e não apresentou corrosão na camada nitretada com revestimento DLC. Pode-se esperar que aplicado essas condições em uma broca cirúrgica, dentro de sua condição de procedimentos cirúrgicos, o desgaste da ferramenta seja menor, uma vez que a sua superfície tem maior dureza do que usualmente comercializada, e mantendo sua resistência à corrosão em ambientes agressivos em que são expostas. / Martensitics stainless steels are used in biomedical applications because of that yours excellent corrosion resistance and good mechanical properties. However, in applications such as drills for implant their performance has been unsatisfactory. This application is usually used how DLC coatings to improve corrosion resistance, wear resistance and to decrease the coefficient of drill bone friction. Several studies in the literature show that nitriding at low temperatures produce surface layers of high hardness and high resistance to corrosion. It is also known that increasing the hardness of the substrate it improves the adhesion of the coating as DLC. These treatments are known as duplex. In this work were studied the effect of low temperature nitriding on the corrosion resistance and hardness of martensitic stainless steel type ASTM 420F, as well as the influence on the hardness and corrosion resistance of nitriding and DLC duplex treatment. Five parameters of nitriding at low temperature, at different times to evaluate the behavior in the hardness and corrosion resistance were chosen. The parameter that had the best performance providing a higher hardness and better corrosion resistance was at 380°C for 6 hours. The average hardness of the drill top was 894 HV (1 Kgf) and not showed corrosion in duplex layer. It can be expected to apply these conditions in a surgical drill, in the tool wear will be less, since the surface has a higher hardness than usually marketed and the drill maintained the resistance to corrosion in aggressive environment that they are exposited.
110

Estudo da ação bactericida em regiões próximas à superfície de titânio e AISI 304 pela incorporação de prata

Soares, Tatiana Pacheco 10 March 2017 (has links)
A contaminação por biofilmes bacterianos tem um forte impacto negativo, especialmente quando aderidos na superfície de próteses, implantes, pinos e outros dispositivos médico-cirúrgicos. Neste trabalho foram produzidas amostras metálicas de titânio e AISI 304 com íons Ag+ implantados por IPD a diferentes energias: 2 e 4 keV; e com diferentes tempos de implantação: 30, 45, 60 e 90 min visando a obtenção de superfícies com propriedades bactericidas. A profundidade e o perfil de distribuição dos íons implantados foram estimados por simulação de Monte Carlo utilizando o software SRIM 2008, juntamente com a determinação da concentração de prata incorporada nas amostras por técnicas espectroscópicas. A atividade bactericida das amostras de titânio com diferentes concentrações de prata foi avaliada por meio do tratamento de um efluente industrial líquido, que foi submetido à contagem de Escherichia coli antes e depois do contato do efluente com as amostras. O ângulo de contato foi medido para avaliação da molhabilidade das amostras de titânio que apresentaram as maiores concentrações de prata, fator determinante na adesão de bactérias e células humanas. A citotoxidade foi avaliada através de teste de viabilidade celular e análise morfológica. Obteve-se uma redução de 27% de E.coli no efluente industrial tratado com a amostra implantada a 4 keV por 45 min, com concentração inicial de 3,35 × 1015 átomos cm-2.Não foi detectado efeito tóxico da prata para células humanas MG63, mesmo considerando as maiores concentrações prata, uma vez que não houve redução na adesão e proliferação celular em relação ao titânio não tratado. Para as amostras de AISI 304, os ensaios de adesão microbiana foram realizados para as bactérias Listeria monocytogenes e Salmonella Enteritidis, resultando em uma redução de 65,9 e 69,8%, respectivamente. Por fim, os resultados mostraram que o tratamento estudado para obtenção de materiais metálicos com ação bactericida é promissor para aplicações na área médica, no entanto é necessário uma avaliação em longo prazo para garantir a segurança de sua utilização. / Submitted by Ana Guimarães Pereira (agpereir@ucs.br) on 2017-07-05T14:10:05Z No. of bitstreams: 1 Tese Tatiana Pacheco Soares Zamboni.pdf: 2896094 bytes, checksum: a93cbf9d375f0634bd1237b20bc12d83 (MD5) / Made available in DSpace on 2017-07-05T14:10:05Z (GMT). No. of bitstreams: 1 Tese Tatiana Pacheco Soares Zamboni.pdf: 2896094 bytes, checksum: a93cbf9d375f0634bd1237b20bc12d83 (MD5) Previous issue date: 2017-07-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES. / Contamination by bacterial biofilms has a strong negative impact, especially when given on the surface of prostheses, implants, pins and other medical-surgical devices. In this study metal samples of Titanium cp and AISI 304 were produced with Ag+ ions implanted by IPD at different energies: 2 and 4 keV and different implantation times: 30, 45, 60 and 90 min to obtain surfaces with bactericidal properties. The depth and the distribution profile of the implanted ions were estimated by Monte Carlo simulation using the SRIM 2008 software. The Ag+ ions concentration incorporated in the samples was determinate by spectroscopic techniques. Bactericidal activity of the titanium samples with different concentration of Ag+ ions was evaluated by the treatment of a liquid industrial waste. It was submitted to Escherichia coli counting before and after the contact of the waste with the samples. The contact angle was measured to evaluate the wettability of the titanium samples that presented the highest silver concentration. Wettability is a determinant factor in the adhesion of bacteria and human cells. Cytotoxicity was evaluated by cell viability test and morphological analysis. A 27% reduction of E. coli in the industrial waste treated with the sample implanted at 4 keV was achieved for 45 min with an initial concentration of 3.35 × 1015 atoms cm2. No toxic effect of silver was detected on human MG63 cells, even considering the higher concentration of silver, since there was no reduction in cell adhesion and proliferation c to untreated titanium. For the AISI 304 samples, the microbial adhesion assays were performed for the bacteria Listeria monocytogenes and Salmonella Enteritidis, resulting in a reduction of 65.9 and 69.8%, respectively. Finally, the results showed that the treatment studied to obtain metallic materials with bactericidal action is promising for applications in the medical field, however a long term evaluation is necessary to guarantee the safety of its use.

Page generated in 0.0667 seconds