• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 9
  • 7
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo para validação de método rápido microbiológico aplicado a teste de esterilidade: técnica de bioluminescência de ATP / Validation of rapid microbiological method applied to sterility test: ATP bioluminescence technique

Picanço, Aline Marinho 25 August 2014 (has links)
Este estudo foi realizado com o objetivo de desenvolvimento e validação do método microbiológico rápido empregando a técnica de bioluminescência de Adenosina Trifosfato (ATP) como método alternativo para o teste de esterilidade. O ATP reage com o sistema enzimático luciferina/luciferase e gera um fóton de luz em presença de íons magnésio, reação que pode ser utilizada na detecção de microrganismos. A luz gerada na reação é medida por um dispositivo chamado luminômetro, que traduz o sinal em unidades relativas de luz (URL), metodologia altamente sensível que pode ser utilizada na análise de produtos estéreis com o objetivo de diminuição no tempo do ensaio. Enquanto a turbidez do meio de cultura só pode ser visualizada quando o contaminante chega à concentração de 106 UFC/ml, a tecnologia de bioluminescência de ATP pode detectar amostras com concentração em torno de 104 UFC. Foram empregados na validação dados obtidos a partir do método tradicional de esterilidade (técnica de filtração) realizado paralelamente ao método alternativo. As soluções parenterais utilizadas nos ensaios foram: solução fisiológica 0,9%; solução de dextrose 5%; ringer lactato; e solução de metronidazol 0,5%. As soluções-teste foram inoculadas intencionalmente com suspensões microbianas preparadas através da diluição de Bioballs&#174, com concentrações de 10 UFC/100 ml, 2 UFC/100 ml e 0,4 UFC/100 ml. Após a realização do teste convencional, as membranas resultantes do ensaio foram incubadas nos meios de cultura caldo caseína de soja e tioglicolato. Alíquotas destes meios foram retiradas após 96 horas de incubação para análise pelo método alternativo. Os seguintes microrganismos foram selecionados para o estudo: Staphylococcus aureus, Bacilus subtilis, Pseudomonas aeruginosa, Candida albicans, Clostridium sporogenes, Aspergillus brasiliensis, Kocuria rosea e Micrococcus luteus. A análise dos resultados obtidos mostrou que o método alternativo é capaz de detectar os microrganismos testados. Quanto à sensibilidade, o método alternativo apresentou vantagem na concentração 2 UFC/100 ml, e equivalência nas outras concentrações. A não interferência dos diferentes produtos e meios nos resultados encontrados permite vislumbrar evidência de robustez do método. Adicionalmente, em relação ao tempo de resposta, o método alternativo demonstrou ser equivalente ao convencional (p-valor=0,43). / This study is being conducted with a goal of validating and developing the fast microbiological method of ATP bioluminescence, as an alternative method to the sterility test. The ATP reacts with the enzymatic system luciferin-luciferase and produces light in the presence of magnesium ions, this reaction can be used for microorganism\'s detection. The light generated in this reaction can be measured by a device called luminometer that translates the signal in relative light units (RLU). This methodology has high sensibility and it can be used in the sterile products analysis with the objective of reducing the time of the sample. While the turbidity of the culture medium it can be visualized just when the sample reaches a concentration of 106 UCF per mL, the bioluminescence assay can detect samples at concentrations around 104 UCF per mL. The both methods, conventional (filtration technique) and alternative were done in parallel and the result data were used in the validation study. It was used in the assay the next parenteral solutions: physiological solution 0,9%, metronidazole solution 0,5%, dextrose solution 5% and Ringer lactate. The test solutions were inoculated with the microorganism suspensions, prepared by the dilution of the Bioballs® with result concentrations of 10 CFU/100 mL, 2 FU/100 mL and 0,4 CFU/ mL. After the conventional test was performed, the result membranes were incubated in thioglicollate and soybean casein broth. After 96 hours of incubation, aliquots from the broth were taken to perform the analysis by the alternative method. The following microorganisms were selected to perform the validation study: Staphylococcus aureus, Bacilus subtilis, Pseudomonas aeruginosa, Clostridium sporogenes, Candida albicans, Aspergillus brasiliensis, Kocuria rosea and Micrococcus luteus. The analysis of results shows that the alternative method can detect the test microorganisms. Regarding of the sensibility, the alternative method shows advantage in the 2 CFU/mL inoculum concentration and equivalence in the other two concentrations. The method shows evidence of robustness because the results were not affected by the products or culture media used in the assay. Additionally concerning the detection time, the alternative method was established equivalent to the conventional method (p-value=0,43).
2

Proposta de um modelo de implementação da liberação paramétrica para produtos com esterilização terminal / Proposal of a model for implementation of parametric release for terminally sterilized products

Ramos, Thais Mitleton Borges 04 August 2014 (has links)
A Liberação Paramétrica (L.P) é definida como a liberação de produtos submetidos à esterilização terminal, por meio do cumprimento de parâmetros críticos do processo de esterilização, sem a necessidade da realização do teste de esterilidade. O conceito da L.P para produtos com esterilização terminal surgiu como uma alternativa à deficiência do teste de esterilidade, pois o teste apresenta limitações, não sendo capaz de garantir que todas as unidades do lote se encontram estéreis. A L.P é um assunto recente no Brasil e que se encontra em processo de regulamentação. Em 2012, a Agência Nacional de Vigilância Sanitária - (ANVISA) iniciou a discussão sobre o tema, dada a importância que este apresenta para país e, recentemente, no inicio do ano de 2014, foi publicada Consulta pública sobre o tema. Desse modo, ainda existem poucas informações sobre o cenário regulatório brasileiro da L.P e como esse conceito deve ser implementado pelas indústrias brasileiras, o que torna relevante a discussão sobre o tema. Sendo assim, o presente trabalho tem como objetivo a proposição de um modelo conceitual para auxiliar a adoção da L.P para indústrias farmacêuticas na substituição ao teste de esterilidade terminal. Após a proposição do modelo, o trabalho busca ainda a aplicação deste em uma indústria de produtos com esterilização terminal, com intuito de avaliar o modelo e agregar novos conhecimentos sobre o conceito da L.P. A metodologia do trabalho que melhor se encaixa à proposta é a pesquisa exploratória, ou seja, pesquisa do tipo teórico-conceitual, como discussões conceituais e pesquisas bibliográficas sobre o tema. Esta pesquisa também é classificada como qualitativa, sem a pretensão de garantir a precisão dos dados, já que se trata da proposição e aplicação de um modelo de implementação da L.P. Por ter um caráter aplicado, a pesquisa também pretende avaliar o modelo proposto, segundo o método da pesquisa-ação em uma indústria de produtos com esterilização terminal, no qual o pesquisador interfere e participa da pesquisa. O trabalho desenvolvido conseguiu atingir resultados satisfatórios, mostrando que o modelo proposto traz benefícios à empresa que pretende utilizá-lo para realizar a adoção da LP, pois, através da aplicação do mesmo, a empresa pode se organizar melhor internamente para conduzir as atividades do projeto. O modelo também é vantajoso, pois trabalha com o conceito de equipes multidisciplinares. Isto favorece a integração entre os membros da organização, proporcionando a troca de conhecimento entre os profissionais e a criação de novos conhecimentos relacionados à LP. O modelo também permite que a empresa adquira melhor conhecimento sobre o processo de fabricação dos produtos estéreis no qual deseja adotar a LP. Pois, através da aplicação da ferramenta de análise de risco para LP, é possível visualizar os pontos críticos de controle para a LP, PCC para LP. E isto permite conhecer criticamente o processo e permite elaborar planos de ação para controlar os riscos existentes desses pontos, a fim de atenderem as exigências para a adoção da LP. / Parametric Release (PR) is defined as the release of products subject to terminal sterilization through fulfillment of critical parameters of the sterilization process without the necessity of completing the terminal sterility test. The concept of PR for terminal sterilization products has emerged as an alternative to the sterility test because of its inability to guarantee that all units in the batch are sterile. PR is a new issue in Brazil, undergoing the regulatory process. In 2012, the Brazilian Agency (Agência Nacional de Vigilância Sanitária - ANVISA) started a debate on the topic given the importance it has for the country and recently, at the beginning of the year 2014 a public survey on the subject was published. Thus, there is little information on PR in the Brazilian regulatory scenario and how this concept should be implemented by Brazilian industries, which becomes relevant to the discussion on the topic. Thus, the present work aims at proposing a conceptual framework to help the adoption of PR as a substitute for the terminal sterility test for pharmaceutical industries. After submitting the model, the present work will also seek to employ this product in a company using terminal sterilization in order to assess the model and add new know-how regarding the concept of PR. The methodology that best suits the proposal is exploratory research, i.e., a theoretical/conceptual-type study, such as conceptual discussions and bibliographic exploration on the topic. This kind of research is also classified as qualitative, without any intent to ensure the accuracy of the data, since it is a proposition and an application of a model for implementation of PR. Due to its character, applied to research, it also aims to evaluate the proposed model using the method of action research in a company using terminal sterilization of products, where the researcher interferes and participates in the study. The work has achieved satisfactory results showing that the proposed model is beneficial to the company that may want to use it to adopt PR, because through the same application, the company can better organize itself internally to conduct project activities. The model is also advantageous because it works with the concept of multidisciplinary teams. This improves the integration between members of the organization providing the knowledge exchange among professionals and generation new knowledge related to PR. The model also allows the company to acquire better knowledge about the process of manufacture of sterile products for which it may want to adopt the PR. For, through the application of risk analysis for the PR tool, one can view the critical control points for PR, (CCPs). And this allows to view the process critically and develop action plans to control the risks relative to these points to meet the requirements for the adoption of PR
3

Validação de teste de esterilidade baseado em detecção de dióxido de carbono / Validation of sterility test based in carbon dioxide detection

Lira, Rodolfo Santos de 09 April 2014 (has links)
De acordo com compêndios farmacêuticos, o teste de esterilidade, requer período de incubação de 14 dias para obtenção de resultado analítico, período em que produto farmacêutico é mantido em quarentena, o que demanda custos elevados. Os métodos alternativos com aplicação na avaliação da esterilidade são particularmente interessantes, quando possibilitam a redução do período de incubação do teste, o período de quarentena e, em consequência, os custos envolvidos, além de reduzir o tempo para preparação do material requerido, para execução do ensaio e para a capacitação técnica. O presente estudo avaliou o desempenho do método microbiológico rápido BacT/Alert 3D (Biomerieux®) aplicado ao teste de esterilidade em comparação ao teste de esterilidade por método indireto descrito nas farmacopeias (brasileira, americana, européia e japonesa). O Bact/Alert 3D se baseia na detecção do crescimento microbiano, que é feita por meio de detecção de alteração da cor de um sensor sensível à liberação de dióxido de carbono produzido por metabolismo microbiano. Os testes utilizaram três diferentes soluções parenterais de grande volume: solução salina 0,9%, concentrado polieletrolítico para diálise e solução de metronidazol. Micro-organismos desafio: Escherichia coli ATCC 8739, Pseudomonas aeruginosa ATCC 9027, Staphylococcus aureus ATCC 6538, Bacillus subtilis ATCC 6633, Clostridium sporogenes ATCC 19404, Candida albicans ATCC 10231 e Aspergillus brasiliensis ATCC 16404. Cargas de contaminação: 20, 2 e 0,2 UFC/membrana. Temperatura de incubação: 32,5 ± 0,5 °C. As amostras foram avaliadas por 14 dias. Amostras dos três produtos foram artificialmente contaminadas com BioBalls® SingleShot dos micro-organismos desafio de diferentes cargas de contaminação foram submetidas ao teste de esterilidade farmacopeico, com inoculação por método indireto. Após 18h de incubação, foram retiradas alíquotas de cada um dos meios de cultura, que foram inoculadas nos frascos de meio de cultura do BacT/Alert 3D. Bact/Alert 3D demonstrou equivalência ao método farmacopeico (p > 0,05) e tempo de detecção inferior. / Nowadays, the harmonized sterility test method described on pharmacopoeias requires an incubation period of 14 days. During this period the product stays on quarantine waiting the result for release, which demands warehousing and inventory costs. The application of Rapid microbiologial methods for sterility testing is particulary interesting considering the benefits of incubation time reduction, quarantine period reduction, time reduction for material preparation, reduction of time for test execution and technical training.This work evaluated comparetivelly the performance of Bact/Alert 3D system as a rapid microbiologial method applied to sterility testing and sterility testing according to described on Brazilian pharmacopeia and harmonized pharmacopeias (American pharmacopeia, European pharmacopeia and Japanese pharmacopeia). The Bact/Alert 3D is based on microrganisms gowth and has as principle the detection of pad color change which is sensible to carbon dioxide release by microorganism metabolism. To perform the evaluation it was considered Buffer saline solution, Metronidazol solution and Polieletrolitic dialysis concentrate solution. Challenge Microrganisms: Staphylococcus aureus (ATCC 6538), Bacilus subtilis (ATCC 6633), Pseudomonas aeruginosa (ATCC 9027), Escherichia coli (ATCC 8739 ), Clostridium sporogenes (ATCC 19404), Candida albicans (ATCC 10231) and Aspergillus brasiliensis (ATCC 16404). Inoculum load: 20CFU/sample; 2 CFU/sample; 0,2CFU/sample. Incubation temperature: 32,5 ± 0,5 °C. The samples were evaluated during 14 days. Aseptic samples of the three products were intentionally contaminated with BioBalls® SingleShot of challenge microorganisms, according to inoculum concentration desired, and were tested by indirect inoculation. After 18h aliquotes of were taken from inoculated culture media and inoculated into BacT/Alert 3D culture media bottles. Bact/Alert showed equivalence to compendial method (p > 0,05) and showed results faster than compendial method.
4

Esterilidade: validação de metodologia e propostas de otimização de resultados / Sterility test: analytical validation and proposal for results improvement

Bugno, Adriana 12 February 2001 (has links)
Este trabalho consiste em um estudo sobre os parâmetros para validação de metodologia para teste de esterilidade. As qualificações das instalações e dos operadores são consideradas etapas integrantes na validação analítica, cuja finalidade abrange minimizar a ocorrência de resultados falso-positivos e falso-negativos. Foram comparadas as eficiências de três métodos de teste de esterilidade empregando inoculação direta, inoculação indireta nos moldes convencionais e inoculação indireta em sistema fechado quanto à detecção do crescimento de diferentes tipos de microrganismos normalmente encontrados como contaminantes em produtos farmacêuticos Aspergillus niger, Bacillus subtilis, Candida albicans, Clostridium sporogenes, Escherichia coli, Micrococcus luteus, Pseudomonas aeruginosa, Saccharomyces cerevisiae e Staphylococcus aureus. Cada um deles foi inoculado em amostras constituídas de frascos plásticos de 10 mL de solução fisiológica em três diferentes níveis de contaminação: 5, 10 e 50 UFC/10 mL. Utilizou-se nos testes diferentes tipos de meios de cultura meio de caseína de soja, meio de tioglicolato, meio Sabouraud e meio Clausen bem como distintas temperaturas de incubação 12, 22, 32 e 42 ºC durante um período de incubação de 28 dias. Os resultados demonstraram que as metodologias aplicadas apresentam diferenças significativas na eficiência de detecção de contaminantes, mesmo quando atendidas condições de equivalência quanto ao número de amostras e volume unitário submetidos ao teste. Verificou-se que as condições preconizadas nos compêndios farmacopeicos quanto aos tipos de meio de cultura, meio de caseína de soja e meio de tioglicolato, as temperaturas de incubação, 22 e 32 ºC, bem como o período de incubação de 14 dias, apresentaram os melhores resultados na detecção de contaminantes microbiológicos. / This paper aims the study of parameters used for validation of methods for sterility tests. Installation and operators qualification are considered a step for analytical validation, in order to reduce the occurrence of false-positive and false-negative results. The efficiency of three methods for sterility tests with direct, conventional indirect and closed system indirect inoculation (Steritest®) was submitted to a comparative study concerning their capacity of growth detection of different types of microorganisms that are most frequently found as contaminants of pharmaceutical products Aspergillus niger, Bacillus subtilis, Candida albicans, Clostridium sporogenes, Escherichia coli, Micrococcus luteus, Pseudomonas aeruginosa, Saccharomyces cerevisiae and Staphylococcus Aureus. Each of them was inoculated in samples of plastic bottles of phisiological solution (10 mL) in three different levels of contamination: 5, 10 and 50 CFU/10 mL. Different types of culture media were used soybean casein, thioglycollate, Sabouraud and Clausen as well as different temperatures of incubation 12, 22, 32 and 42 ºC during an incubation period of 28 days. The results showed significant differences between the methodologies applied in what concerns the detection of contaminantion, even an equivalent number of samples and content of each unit submited to test. The best results for microbial contaminants detection were obtained as described in pharmacopeias in what concerns the types of culture medium, soybean casein media and thioglycollate media, the temperatures of incubation, 22 and 32 ºC, and the incubation period of 14 days.
5

Esterilidade: validação de metodologia e propostas de otimização de resultados / Sterility test: analytical validation and proposal for results improvement

Adriana Bugno 12 February 2001 (has links)
Este trabalho consiste em um estudo sobre os parâmetros para validação de metodologia para teste de esterilidade. As qualificações das instalações e dos operadores são consideradas etapas integrantes na validação analítica, cuja finalidade abrange minimizar a ocorrência de resultados falso-positivos e falso-negativos. Foram comparadas as eficiências de três métodos de teste de esterilidade empregando inoculação direta, inoculação indireta nos moldes convencionais e inoculação indireta em sistema fechado quanto à detecção do crescimento de diferentes tipos de microrganismos normalmente encontrados como contaminantes em produtos farmacêuticos Aspergillus niger, Bacillus subtilis, Candida albicans, Clostridium sporogenes, Escherichia coli, Micrococcus luteus, Pseudomonas aeruginosa, Saccharomyces cerevisiae e Staphylococcus aureus. Cada um deles foi inoculado em amostras constituídas de frascos plásticos de 10 mL de solução fisiológica em três diferentes níveis de contaminação: 5, 10 e 50 UFC/10 mL. Utilizou-se nos testes diferentes tipos de meios de cultura meio de caseína de soja, meio de tioglicolato, meio Sabouraud e meio Clausen bem como distintas temperaturas de incubação 12, 22, 32 e 42 ºC durante um período de incubação de 28 dias. Os resultados demonstraram que as metodologias aplicadas apresentam diferenças significativas na eficiência de detecção de contaminantes, mesmo quando atendidas condições de equivalência quanto ao número de amostras e volume unitário submetidos ao teste. Verificou-se que as condições preconizadas nos compêndios farmacopeicos quanto aos tipos de meio de cultura, meio de caseína de soja e meio de tioglicolato, as temperaturas de incubação, 22 e 32 ºC, bem como o período de incubação de 14 dias, apresentaram os melhores resultados na detecção de contaminantes microbiológicos. / This paper aims the study of parameters used for validation of methods for sterility tests. Installation and operators qualification are considered a step for analytical validation, in order to reduce the occurrence of false-positive and false-negative results. The efficiency of three methods for sterility tests with direct, conventional indirect and closed system indirect inoculation (Steritest®) was submitted to a comparative study concerning their capacity of growth detection of different types of microorganisms that are most frequently found as contaminants of pharmaceutical products Aspergillus niger, Bacillus subtilis, Candida albicans, Clostridium sporogenes, Escherichia coli, Micrococcus luteus, Pseudomonas aeruginosa, Saccharomyces cerevisiae and Staphylococcus Aureus. Each of them was inoculated in samples of plastic bottles of phisiological solution (10 mL) in three different levels of contamination: 5, 10 and 50 CFU/10 mL. Different types of culture media were used soybean casein, thioglycollate, Sabouraud and Clausen as well as different temperatures of incubation 12, 22, 32 and 42 ºC during an incubation period of 28 days. The results showed significant differences between the methodologies applied in what concerns the detection of contaminantion, even an equivalent number of samples and content of each unit submited to test. The best results for microbial contaminants detection were obtained as described in pharmacopeias in what concerns the types of culture medium, soybean casein media and thioglycollate media, the temperatures of incubation, 22 and 32 ºC, and the incubation period of 14 days.
6

Validação de teste de esterilidade baseado em detecção de dióxido de carbono / Validation of sterility test based in carbon dioxide detection

Rodolfo Santos de Lira 09 April 2014 (has links)
De acordo com compêndios farmacêuticos, o teste de esterilidade, requer período de incubação de 14 dias para obtenção de resultado analítico, período em que produto farmacêutico é mantido em quarentena, o que demanda custos elevados. Os métodos alternativos com aplicação na avaliação da esterilidade são particularmente interessantes, quando possibilitam a redução do período de incubação do teste, o período de quarentena e, em consequência, os custos envolvidos, além de reduzir o tempo para preparação do material requerido, para execução do ensaio e para a capacitação técnica. O presente estudo avaliou o desempenho do método microbiológico rápido BacT/Alert 3D (Biomerieux®) aplicado ao teste de esterilidade em comparação ao teste de esterilidade por método indireto descrito nas farmacopeias (brasileira, americana, européia e japonesa). O Bact/Alert 3D se baseia na detecção do crescimento microbiano, que é feita por meio de detecção de alteração da cor de um sensor sensível à liberação de dióxido de carbono produzido por metabolismo microbiano. Os testes utilizaram três diferentes soluções parenterais de grande volume: solução salina 0,9%, concentrado polieletrolítico para diálise e solução de metronidazol. Micro-organismos desafio: Escherichia coli ATCC 8739, Pseudomonas aeruginosa ATCC 9027, Staphylococcus aureus ATCC 6538, Bacillus subtilis ATCC 6633, Clostridium sporogenes ATCC 19404, Candida albicans ATCC 10231 e Aspergillus brasiliensis ATCC 16404. Cargas de contaminação: 20, 2 e 0,2 UFC/membrana. Temperatura de incubação: 32,5 ± 0,5 °C. As amostras foram avaliadas por 14 dias. Amostras dos três produtos foram artificialmente contaminadas com BioBalls® SingleShot dos micro-organismos desafio de diferentes cargas de contaminação foram submetidas ao teste de esterilidade farmacopeico, com inoculação por método indireto. Após 18h de incubação, foram retiradas alíquotas de cada um dos meios de cultura, que foram inoculadas nos frascos de meio de cultura do BacT/Alert 3D. Bact/Alert 3D demonstrou equivalência ao método farmacopeico (p > 0,05) e tempo de detecção inferior. / Nowadays, the harmonized sterility test method described on pharmacopoeias requires an incubation period of 14 days. During this period the product stays on quarantine waiting the result for release, which demands warehousing and inventory costs. The application of Rapid microbiologial methods for sterility testing is particulary interesting considering the benefits of incubation time reduction, quarantine period reduction, time reduction for material preparation, reduction of time for test execution and technical training.This work evaluated comparetivelly the performance of Bact/Alert 3D system as a rapid microbiologial method applied to sterility testing and sterility testing according to described on Brazilian pharmacopeia and harmonized pharmacopeias (American pharmacopeia, European pharmacopeia and Japanese pharmacopeia). The Bact/Alert 3D is based on microrganisms gowth and has as principle the detection of pad color change which is sensible to carbon dioxide release by microorganism metabolism. To perform the evaluation it was considered Buffer saline solution, Metronidazol solution and Polieletrolitic dialysis concentrate solution. Challenge Microrganisms: Staphylococcus aureus (ATCC 6538), Bacilus subtilis (ATCC 6633), Pseudomonas aeruginosa (ATCC 9027), Escherichia coli (ATCC 8739 ), Clostridium sporogenes (ATCC 19404), Candida albicans (ATCC 10231) and Aspergillus brasiliensis (ATCC 16404). Inoculum load: 20CFU/sample; 2 CFU/sample; 0,2CFU/sample. Incubation temperature: 32,5 ± 0,5 °C. The samples were evaluated during 14 days. Aseptic samples of the three products were intentionally contaminated with BioBalls® SingleShot of challenge microorganisms, according to inoculum concentration desired, and were tested by indirect inoculation. After 18h aliquotes of were taken from inoculated culture media and inoculated into BacT/Alert 3D culture media bottles. Bact/Alert showed equivalence to compendial method (p > 0,05) and showed results faster than compendial method.
7

Estudo para validação de método rápido microbiológico aplicado a teste de esterilidade: técnica de bioluminescência de ATP / Validation of rapid microbiological method applied to sterility test: ATP bioluminescence technique

Aline Marinho Picanço 25 August 2014 (has links)
Este estudo foi realizado com o objetivo de desenvolvimento e validação do método microbiológico rápido empregando a técnica de bioluminescência de Adenosina Trifosfato (ATP) como método alternativo para o teste de esterilidade. O ATP reage com o sistema enzimático luciferina/luciferase e gera um fóton de luz em presença de íons magnésio, reação que pode ser utilizada na detecção de microrganismos. A luz gerada na reação é medida por um dispositivo chamado luminômetro, que traduz o sinal em unidades relativas de luz (URL), metodologia altamente sensível que pode ser utilizada na análise de produtos estéreis com o objetivo de diminuição no tempo do ensaio. Enquanto a turbidez do meio de cultura só pode ser visualizada quando o contaminante chega à concentração de 106 UFC/ml, a tecnologia de bioluminescência de ATP pode detectar amostras com concentração em torno de 104 UFC. Foram empregados na validação dados obtidos a partir do método tradicional de esterilidade (técnica de filtração) realizado paralelamente ao método alternativo. As soluções parenterais utilizadas nos ensaios foram: solução fisiológica 0,9%; solução de dextrose 5%; ringer lactato; e solução de metronidazol 0,5%. As soluções-teste foram inoculadas intencionalmente com suspensões microbianas preparadas através da diluição de Bioballs&#174, com concentrações de 10 UFC/100 ml, 2 UFC/100 ml e 0,4 UFC/100 ml. Após a realização do teste convencional, as membranas resultantes do ensaio foram incubadas nos meios de cultura caldo caseína de soja e tioglicolato. Alíquotas destes meios foram retiradas após 96 horas de incubação para análise pelo método alternativo. Os seguintes microrganismos foram selecionados para o estudo: Staphylococcus aureus, Bacilus subtilis, Pseudomonas aeruginosa, Candida albicans, Clostridium sporogenes, Aspergillus brasiliensis, Kocuria rosea e Micrococcus luteus. A análise dos resultados obtidos mostrou que o método alternativo é capaz de detectar os microrganismos testados. Quanto à sensibilidade, o método alternativo apresentou vantagem na concentração 2 UFC/100 ml, e equivalência nas outras concentrações. A não interferência dos diferentes produtos e meios nos resultados encontrados permite vislumbrar evidência de robustez do método. Adicionalmente, em relação ao tempo de resposta, o método alternativo demonstrou ser equivalente ao convencional (p-valor=0,43). / This study is being conducted with a goal of validating and developing the fast microbiological method of ATP bioluminescence, as an alternative method to the sterility test. The ATP reacts with the enzymatic system luciferin-luciferase and produces light in the presence of magnesium ions, this reaction can be used for microorganism\'s detection. The light generated in this reaction can be measured by a device called luminometer that translates the signal in relative light units (RLU). This methodology has high sensibility and it can be used in the sterile products analysis with the objective of reducing the time of the sample. While the turbidity of the culture medium it can be visualized just when the sample reaches a concentration of 106 UCF per mL, the bioluminescence assay can detect samples at concentrations around 104 UCF per mL. The both methods, conventional (filtration technique) and alternative were done in parallel and the result data were used in the validation study. It was used in the assay the next parenteral solutions: physiological solution 0,9%, metronidazole solution 0,5%, dextrose solution 5% and Ringer lactate. The test solutions were inoculated with the microorganism suspensions, prepared by the dilution of the Bioballs® with result concentrations of 10 CFU/100 mL, 2 FU/100 mL and 0,4 CFU/ mL. After the conventional test was performed, the result membranes were incubated in thioglicollate and soybean casein broth. After 96 hours of incubation, aliquots from the broth were taken to perform the analysis by the alternative method. The following microorganisms were selected to perform the validation study: Staphylococcus aureus, Bacilus subtilis, Pseudomonas aeruginosa, Clostridium sporogenes, Candida albicans, Aspergillus brasiliensis, Kocuria rosea and Micrococcus luteus. The analysis of results shows that the alternative method can detect the test microorganisms. Regarding of the sensibility, the alternative method shows advantage in the 2 CFU/mL inoculum concentration and equivalence in the other two concentrations. The method shows evidence of robustness because the results were not affected by the products or culture media used in the assay. Additionally concerning the detection time, the alternative method was established equivalent to the conventional method (p-value=0,43).
8

Proposta de um modelo de implementação da liberação paramétrica para produtos com esterilização terminal / Proposal of a model for implementation of parametric release for terminally sterilized products

Thais Mitleton Borges Ramos 04 August 2014 (has links)
A Liberação Paramétrica (L.P) é definida como a liberação de produtos submetidos à esterilização terminal, por meio do cumprimento de parâmetros críticos do processo de esterilização, sem a necessidade da realização do teste de esterilidade. O conceito da L.P para produtos com esterilização terminal surgiu como uma alternativa à deficiência do teste de esterilidade, pois o teste apresenta limitações, não sendo capaz de garantir que todas as unidades do lote se encontram estéreis. A L.P é um assunto recente no Brasil e que se encontra em processo de regulamentação. Em 2012, a Agência Nacional de Vigilância Sanitária - (ANVISA) iniciou a discussão sobre o tema, dada a importância que este apresenta para país e, recentemente, no inicio do ano de 2014, foi publicada Consulta pública sobre o tema. Desse modo, ainda existem poucas informações sobre o cenário regulatório brasileiro da L.P e como esse conceito deve ser implementado pelas indústrias brasileiras, o que torna relevante a discussão sobre o tema. Sendo assim, o presente trabalho tem como objetivo a proposição de um modelo conceitual para auxiliar a adoção da L.P para indústrias farmacêuticas na substituição ao teste de esterilidade terminal. Após a proposição do modelo, o trabalho busca ainda a aplicação deste em uma indústria de produtos com esterilização terminal, com intuito de avaliar o modelo e agregar novos conhecimentos sobre o conceito da L.P. A metodologia do trabalho que melhor se encaixa à proposta é a pesquisa exploratória, ou seja, pesquisa do tipo teórico-conceitual, como discussões conceituais e pesquisas bibliográficas sobre o tema. Esta pesquisa também é classificada como qualitativa, sem a pretensão de garantir a precisão dos dados, já que se trata da proposição e aplicação de um modelo de implementação da L.P. Por ter um caráter aplicado, a pesquisa também pretende avaliar o modelo proposto, segundo o método da pesquisa-ação em uma indústria de produtos com esterilização terminal, no qual o pesquisador interfere e participa da pesquisa. O trabalho desenvolvido conseguiu atingir resultados satisfatórios, mostrando que o modelo proposto traz benefícios à empresa que pretende utilizá-lo para realizar a adoção da LP, pois, através da aplicação do mesmo, a empresa pode se organizar melhor internamente para conduzir as atividades do projeto. O modelo também é vantajoso, pois trabalha com o conceito de equipes multidisciplinares. Isto favorece a integração entre os membros da organização, proporcionando a troca de conhecimento entre os profissionais e a criação de novos conhecimentos relacionados à LP. O modelo também permite que a empresa adquira melhor conhecimento sobre o processo de fabricação dos produtos estéreis no qual deseja adotar a LP. Pois, através da aplicação da ferramenta de análise de risco para LP, é possível visualizar os pontos críticos de controle para a LP, PCC para LP. E isto permite conhecer criticamente o processo e permite elaborar planos de ação para controlar os riscos existentes desses pontos, a fim de atenderem as exigências para a adoção da LP. / Parametric Release (PR) is defined as the release of products subject to terminal sterilization through fulfillment of critical parameters of the sterilization process without the necessity of completing the terminal sterility test. The concept of PR for terminal sterilization products has emerged as an alternative to the sterility test because of its inability to guarantee that all units in the batch are sterile. PR is a new issue in Brazil, undergoing the regulatory process. In 2012, the Brazilian Agency (Agência Nacional de Vigilância Sanitária - ANVISA) started a debate on the topic given the importance it has for the country and recently, at the beginning of the year 2014 a public survey on the subject was published. Thus, there is little information on PR in the Brazilian regulatory scenario and how this concept should be implemented by Brazilian industries, which becomes relevant to the discussion on the topic. Thus, the present work aims at proposing a conceptual framework to help the adoption of PR as a substitute for the terminal sterility test for pharmaceutical industries. After submitting the model, the present work will also seek to employ this product in a company using terminal sterilization in order to assess the model and add new know-how regarding the concept of PR. The methodology that best suits the proposal is exploratory research, i.e., a theoretical/conceptual-type study, such as conceptual discussions and bibliographic exploration on the topic. This kind of research is also classified as qualitative, without any intent to ensure the accuracy of the data, since it is a proposition and an application of a model for implementation of PR. Due to its character, applied to research, it also aims to evaluate the proposed model using the method of action research in a company using terminal sterilization of products, where the researcher interferes and participates in the study. The work has achieved satisfactory results showing that the proposed model is beneficial to the company that may want to use it to adopt PR, because through the same application, the company can better organize itself internally to conduct project activities. The model is also advantageous because it works with the concept of multidisciplinary teams. This improves the integration between members of the organization providing the knowledge exchange among professionals and generation new knowledge related to PR. The model also allows the company to acquire better knowledge about the process of manufacture of sterile products for which it may want to adopt the PR. For, through the application of risk analysis for the PR tool, one can view the critical control points for PR, (CCPs). And this allows to view the process critically and develop action plans to control the risks relative to these points to meet the requirements for the adoption of PR
9

Otimização do processo de descontaminação no sistema isolador de Bio-Manguinhos

Cyranka, Beatriz January 2011 (has links)
Submitted by Priscila Nascimento (pnascimento@icict.fiocruz.br) on 2012-11-30T12:31:09Z No. of bitstreams: 1 beatriz-cyranka.pdf: 1720638 bytes, checksum: c436adb348584d5a5a8213fccdef6ea6 (MD5) / Made available in DSpace on 2012-11-30T12:31:09Z (GMT). No. of bitstreams: 1 beatriz-cyranka.pdf: 1720638 bytes, checksum: c436adb348584d5a5a8213fccdef6ea6 (MD5) Previous issue date: 2011 / Fundação Oswaldo Cruz. Instituto de Tecnologia em Imunobiológicos. Rio de Janeiro, RJ, Brasil. / Novas tecnologias, como o sistema isolador para ensaios de esterilidade vieram a contribuir com a incorporação de um melhor desempenho destes ensaios no controle de qualidade das indústrias farmacêuticas.Este trabalho teve como objetivo a verificação do processo de biodescontaminação dentro do sistema isolador de Bio-Manguinhos, utilizado como agente esterilizante o gás de peróxido de hidrogênio. Foram utilizadas como biocarga para redução de contaminação microbiológica três concentrações dos microrganismos, Candida albicansATCC 10231, Clostridium sporogenesATCC 11437 eMicrococcus luteusATCC 9341, impregnadas em discos de filtro de celulose. Os estudos de cinética de crescimento dos microrganismos foram realizados para um melhor entendimento do seumetabolismo, bem como aspectos gerais de crescimento que contribuíram para ressaltar que a Candida albicans inicia sua fase exponencial de crescimento na segunda hora do cultivo e finaliza esta etapa na sexta hora do cultivo, com produção máxima de células viáveis, fato observado também no microrganismo Micrococccus luteus. Para o cultivo doClostridium sporogenes o crescimento foi mais lento com uma curva de crescimento com 60 horas de cultivo total. A produção de maior número de células para o Clostridiumfoi alcançada na vigésima quarta hora de cultivo, assim como a maior produção de esporos. Foi estabelecida, ao longo da curva de crescimento, a relação entre densidade ótica e número de células viáveis, relação essa importante para o estabelecimento das condições do estudo em relação à biocarga empregada de cada microrganismo no momento do desafio no sistema isolador. A capacidade de descontaminação avaliada dentro do sistema isolador com o biocida peróxido de hidrogênio revelou o tempo de exposição ao gás de 10 minutos, como resultado final satisfatório apresentando redução total da carga microbiana com destruição total das células viáveis, assim como as formas esporuladas do Clostridium sporogenes. Desta forma conclui-se que o peróxido de hidrogênioé um biocida de eficácia comprovada, nas variáveis deste estudo e o processode descontaminação no sistema isolador de Bio-Manguinhos é compatível comsua atividade finalística na produção de insumos para a saúde. / New technologies such as isolator system for sterility tests came to help with the incorporation of a better performance of these kinds of tests in quality control of pharmaceutical companies. This study aimed to verify the decontamination process within the system isolator of Bio-Manguinhos, usinghydrogen peroxide gas as a sterilizing agent. Three concentrations of microorganisms were used as bioburden for the microbiological contamination reduction, Candida albicansATCC 10231, Clostridium sporogenesATCC 11437 and Micrococcus luteusATCC 9341, impregnated in cellulose filter discs. Studies of growth kinetics of microorganisms were carried out to a better understanding of theirmetabolism, as well as general aspects of growth that contributed to emphasize that the Candida albicansbegins its exponential growth phase in the second hour of cultivation and this step ends at the sixth hour cultivation, with maximum yield of viable cells, this was also observed in the Micrococcus luteusmicroorganism. For the Clostridium sporogenescultivation, growth was slower with a 60 hours growth curve of total culture. The production of more cells for Clostridiumwas achieved in the twenty-fourth hour of cultivation, as well as the maximum spores production. It was established along the growth curve the relationship between optical density and numberof viable cells, this relationship was important to establish the conditions of the study related to the bioburden of each microorganism used to challenge the isolator system. The decontamination capacity evaluated within the isolator system with the hydrogen peroxide biocide showed that the gas exposure time of 10 minutes wassatisfactory demonstrating total reduction of the microbial load with total destruction of viable cells, as well as the sporulated forms of Clostridium sporogenes. Thus it is concluded that hydrogen peroxide is a proved effective biocide, in the variables of this study and decontamination process in the Bio-Manguinhos insulator system is compatible with its main activity in the production of health supplies.

Page generated in 0.0965 seconds