• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 78
  • Tagged with
  • 78
  • 78
  • 25
  • 22
  • 22
  • 19
  • 18
  • 17
  • 16
  • 15
  • 14
  • 14
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do exercício aeróbio prévio realizado em diferentes cadências de pedalada sobre o número máximo de repetições na musculação e a capacidade de saltos /

Ruas, Vinícius Daniel de Araújo. January 2007 (has links)
Orientador: Camila Coelho Greco / Banca: Emerson Franchini / Banca: Mauro Gonçalves / Resumo: Em muitos programas de condicionamento físico ou de treinamento esportivo, os indivíduos têm de realizar exercícios aeróbios e de força na mesma sessão. No entanto, o treinamento concorrente demanda adaptações específicas para a melhora do rendimento aeróbio e do rendimento de força, e pode, dependendo das condições que forem realizados, comprometerem o rendimento da força. Portanto, os objetivos deste estudo foram: a) Analisar o efeito do exercício aeróbio realizado no ciclismo sobre a força muscular subseqüente, e; b) Verificar se o efeito do exercício aeróbio prévio é dependente do tipo de exercício de força realizado. Doze indivíduos do gênero masculino fisicamente ativos (23 l 3,7 anos, 77,2 l 8,9 kg, 179,3 l 4 cm, 14,34 l 2,99% gordura) executaram 2 testes incrementais até a exaustão em diferentes cadências de pedalada (50 rev.min-1 e 100 rev.min-1) para determinação do LAn, e um protocolo para a determinação da carga equivalente a 10 repetições máximas (10RM) em um aparelho leg-press 45°. Após a realização destes, os mesmos executaram três séries de repetições máximas com a carga de 10RM no leg-press (L) ou três séries de 10 saltos máximos em uma plataforma de saltos (S), nas seguintes condições: 1) Controle (LC e SC); 2) L50 e S50 após a realização de um exercício de 30 minutos no LAn na cadência de 50 rev.min-1; 3) L100 e S100 após a realização de um exercício de 30 minutos no LAn na cadência de 100 rev.min-1. Houve uma redução significante do número de repetições na primeira série nas condições L50 (10 l 1) e L100 (9 l 2) em relação à LC (12 l 2), e na terceira série na condição L100 (6 l 2) comparada à LC (9 l 1). Houve uma redução significante na altura média de saltos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In several physical conditioning and sports training programs, individuals have to perform aerobic and strength exercises in the same training session. However, the concurrent training demands specific adaptations to the improvement of aerobic and strength performance and, depending of the conditions which they are performed, the strength performance can be compromised. Thus, the purposes of this study were: a) To analyze the effect of aerobic exercise performed in cycling on subsequent muscular strength, and; b) To analyze if the effect of previous aerobic exercise is dependent on the type of the strength exercise. Twelve active males (23 l 3.7 years, 77.17 l 8.86 kg, 179.33 l 4.03 cm, 14.34 l 2.99% body fat) performed 2 incremental tests until exhaustion in different pedal cadences (50 rev.min-1 and 100 rev.min-1) to in order to determine the anaerobic threshold (AT), and a protocol to determine the workload corresponding to 10 maximal repetitions (10RM) in leg press 45°. Then, they performed 3 sets of maximal repetitions with workload of 10RM in leg press (L) or 3 sets of 10 maximal countermovement jumps in a contact plate (S), in the following conditions: 1) Control (LC and SC); 2) L50 and S50 after 30 minutes of cycling at AT and pedal cadence of 50 rev.min-1; 3) L100 and S100 after 30 minutes of cycling at AT and pedal cadence of 100 rev.min-1. There was a significant reduction on the number of repetitions performed in the first set at the conditions L50 (10 l 1) and L100 (9 l 2) in relation to LC (12 l 2), and in the third set at the condition L100 (6 l 2) compared to LC (9 l 1). There was a significant reduction in the mean jump height in the first (29.0 l 4.1 cm) and third (29.1 l 2.9 cm) sets at S50 in relation to SC (32.0 l 3.3 cm and 31.8 l 2.9 cm, respectively). Thus, at these... (Complete abstract click electronic access below) / Mestre
2

Efeito da via de parto na força muscular do assoalho pélvico, em primíparas /

Barbosa, Angélica Mércia Pascon. January 2004 (has links)
Orientador: Marilza Vieira Cunha Rudge / Resumo: Objetivo - Determinar a influência da via de parto na força muscular do assoalho pélvico (AP) de primíparas, 4 a 6 meses pósparto. Sujeitos e Métodos - Estudo clínico, de corte transversal, para avaliar a função da musculatura do AP pelo teste da AFA e perineômetro pneumático e classificada em: zero - ausência de contração muscular, um - contração leve, dois - contração moderada não sustentada por 6 segundos e, três - contração normal sustentada por 6 segundos. As 94 mulheres, tinham entre 20 e 30 anos, foram divididas em 3 grupos de acordo com a via de parto: I com 32 primíparas pós-parto vaginal; II com 32 primíparas pós-parto cesárea e III com 30 nulíparas que serviram como grupo controle. A variável independente foi a via de parto e a dependente a força muscular do AP(1). Resultados e conclusões - A mediana e o 1º e 3º quartís da força muscular do AP foram menores (p=0.01) pós-parto vaginal (2.0;1-2) e intermediária pós-parto cesárea (2.0; 2-3) em relação as nulíparas (3.0;2-3) pelo AFA e perineômetro. Aumentou o risco relativo(RR) de exame alterado da força da musculatura do AP pós-parto vaginal (RR=2.579 IC 95%=1.32-5.04 p=0.002); (RR=2.31 IC 95%=1.24- 4.32 p=0.005) e pós-cesárea (RR=1.56 IC 95% = 0.94-2.57 p=0.12); (RR=1.38 IC 95%=0.85-2.23 p=0.29) pela AFA e perineômetro. O parto vaginal diminuiu a força muscular do AP de primíparas e comparando com a cesárea e as nulíparas. / Abstract: Objective - To evaluate the influence of the route of delivery on pelvic floor (PF) muscle strength, in primiparous patients at 4 to 6 months after delivery. Subjects and methods - A cross-sectional study was undertaken among primiparous women at 4 to 6 months postpartum to evaluate the PF muscle strength by AFA test and pneumatic perineometer, classified in: zero - lack of muscle contraction; one - weak contraction; two - moderate contraction not sustained for 6 seconds and three - normal contraction sustained for 6 seconds. 94 enrolled patients were divided in three groups based upon prior delivery route: I) 32 vaginal delivery with singleton cephalic presentation; II) 32 cesarean delivery; and III) 30 nuliparous patients served as a control group. The independent variable was the route of delivery and the dependent one was the muscle strength of the PF. Data were subjected to Student t test to estimate the relative risk and the Kappa test(1). Results and conclusions - The three subgroups were comparable with respect to maternal age, weight, gestational age and newborn weight. The 1st and the 3rd quartiles of the route of delivery on PF muscle strength were lower (p=0.01) for vaginal delivery (n=32) (2.0;1- 2) and intermediate for cesarean (n=32) (2.0; 2-3) comparing to the nuliparous (3.0; 2-3) by AFA test and pneumatic perineometer. The altered PF muscle strength in primiparous were significantly lower in the vaginal delivery group (RR=2.58, CI 95%=1.32-5.04, p=0.002); (RR=2.31, CI 95%=1.24-4.32, p=0.005); and postcesarean (RR=1.56, CI 95% = 0.94- 2.57, p= 0.12); (RR=1.38, CI 95%=0.85-2.23, p=0.29). Vaginal delivery decreases PF muscle strength when compared with caesarean delivery and control. / Mestre
3

Desenvolvimento de pino intra-radicular, resistência à fratura e análise da distribuição de tensões através do método dos elementos finitos /

Yamamoto, Eron Toshio Colauto. January 2008 (has links)
Resumo: A proposta do estudo foi avaliar um pino intra-radicular pré-fabricado metálico em titânio puro com rosca, projetado e desenvolvido na faculdade de odontologia de São José dos Campos - UNESP. O pino desenvolvido tem como objetivo, minimizar tanto as tensões que são encontradas quando do uso de pinos pré-fabricados quanto o custo benefício. Para a análise do pino utilizou-se o teste de resistência à fratura do conjunto pino/munhão/raiz, análise da fratura por microscopia e análise de tensões por elementos finitos. Foram analisados quatro sistemas de pinos metálicos pré-fabricados, divididos nos seguintes grupos: Grupo 1 - Pino desenvolvido, Grupo 2 - Pino desenvolvido modificado, Grupo 3 - Flexi Post, Grupo 4 - Para Post. Na resistência à fratura foram utilizados 40 dentes bovinos distribuídos aleatoriamente pelos grupos (n=10) e utilizados para a confecção de corpos de prova simulando a situação encontrada em boca. Os corpos de prova foram levados para uma máquina de ensaio universal (EMIC) e realizado o teste de compressão até sua fratura. Após a fratura dos corpos de prova, aquelas raízes que fraturaram foram fatiadas e analisadas microscopicamente. No método dos elementos finitos foram simulados os corpos de prova do teste de resistência à fratura em modelos computacionais para verificar a distribuição de tensões dos pinos estudados. Os três testes realizados tiveram resultados que interagiram. Conclui-se que os pinos desenvolvidos obtiveram bons resultados diante da análise de resistência à fratura e da análise de tensões com os melhores resultados. / Abstract: The aim of this study was to evaluate a metallic prefabricated intraradicular post in titanium with thread, projected and developed by the author and advisors of this study with the objective of minimizing the tensions found when used of prefabricated posts and to minimize the cost. For the analysis were used fracture strength test, analysis of the fracture image by microscope and tensions analysis for finite elements method. In this study was analysed four metallic prefabricated posts systems, divided in: Group 1 - projected post, Group 2 - modified projected post, Group 3 - Flexi Post, Group 4 - Para Post. In the fracture strength test 40 bovine teeth were used (n=10) for to make the specimens simulating the situation found in mouth. The specimens were submitted to compressive strength test in a universal machine (EMIC) until fracture occurred. After the fracture, the fractured specimens were sliced and analyzed by microscope. In the finite element method the specimens of fracture strenght were simulated in computer models and analysed tensions distribution of the posts. Concluded that the projected posts behaved well in the fracture strength test and the tension analysis obtending the best results. The finite element test was validated by the fracture strength test and still for the microscopic image of the fracture. / Orientador: Clovis Pagani / Coorientador: Eduardo Galera da Silva / Banca: Eduardo Shigueyuki Uemura / Banca: Pedro Yoshito Noritomi / Mestre
4

Avaliação da influência da incorporação de substâncias desinfetantes na resistência à compressão e à tração diametral de dois gessos tipo IV /

Batista, André Ulisses Dantas. January 2005 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Sérgio Russi / Banca: Sergio Sualdini Nogueira / Banca: Cláudia Helena Lovato da Silva / Banca: Helena de Freitas Oliveira Paranhos / Resumo: O objetivo deste estudo foi analisar a influência da incorporação de três desinfetantes (hipoclorito de sódio a 1%, glutaraldeído alcalino a 2% e digluconato de clorexidina a 2%) em duas diferentes porcentagens de substituição da água da espatulação (50 e 100%) de dois gessos tipo IV, FujiRock EP (M1) e Rock Plus (M2), avaliando-se a resistência à compressão e à tração diametral. Os corpos-de-prova foram obtidos a partir de matrizes metálicas bipartidas com 20 mm de diâmetro e 40 mm de altura (resistência à compressão) e 20 mm de diâmetro e 10 mm de altura (resistência à tração diametral). As matrizes foram fixadas sobre uma placa de vidro, o gesso foi manipulado na proporção água/pó recomendada pelos fabricantes (M1:20ml/100g e M2:19 ml/100g), em um espatulador mecânico por 30 segundos, e vazado sob vibração. Para cada ensaio foram confeccionados sete grupos para cada gesso (n=10). Os grupos foram: CONTROLE (Água destilada), G50 (substituição de 50% da água de espatulação por glutaraldeído), G100 (100% de glutaraldeído), C50 (substituição de 50% da água por clorexidina), C100 (100% de clorexidina), H50 (substituição de 50% da água por hipoclorito) e H100 (100% de hipoclorito). Após a presa os corpos-de-prova foram removidos das matrizes e armazenados à temperatura ambiente. Os ensaio de compressão e tração diametral foram realizados 24 horas após o vazamento, em uma máquina de ensaios MTS-810, com célula de carga de 100 KN à velocidade de 0,5mm/min. Os valores médios de resistência à compressão e à tração diametral (MPa) foram submetidos à análise de variância e teste de Tukey, com nível de significância de 95%, permitindo concluir que: (a) a incorporação das substâncias desinfetantes estudadas afetou a resistência à compressão de ambos os gessos analisados; (b) as diferentes proporções de incorporação das substâncias... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the compressive and diametral tensile strength of two Type IV dental stones, FujiRock EP (M1) e Rock Plus (M2), mixed with three disinfectant solutions (sodium hypochlorite 1%, chlorhexidine digluconate 2% and glutaraldehyde 2%) in two different proportions of gauging water (50% and 100%). Compressive samples consisted of cylindrical specimens, each having a diameter of 20 mm and length of 40 mm, and diametral tensile specimens consisted of discshaped specimens, having a diameter of 20 mm and length of 10 mm, obtained from split metal molds. The stone was mixed with the solutions previously outlined at the water-powder ratio recommended by the manufacturers (M1:20ml/100g e M2:19 ml/100g), mechanically spatulated under vacuum (Turbomix) for 30 seconds, and gently vibrated in the molds. Seven groups were prepared for each test, with 10 samples each, as follows: CONTROL (distilled water), G50 (substitution of 50% of gauging water by glutaraldehyde), G100 (only glutaraldehyde), C50 (substitution of 50% of gauging water by chlorhexidine digluconate), C100 (only chlorhexidine digluconate), H50 (substitution of 50% of gauging water by sodium hypochlorite) and H100 (only sodium hypochlorite). Specimens were removed from the molds after they set. Compressive strength and diametral tensile strength was determined 24 hours the specimens were cast, in an MTS-810 testing machine, with a cross-head speed of 0,5mm/min. Mean compressive and diametral tensile strength was calculated and expressed in megapascals (MPa). Data from both tests were analyzed by ANOVA and Tukey test, showing that: (a) chemical disinfectants incorporation reduced the compressive strength of type IV dental stones evaluated; (b) the use of two different proportions of gauging water substitution by disinfectants (50% and 100%) has affected the compressive strength of only one die stone (M1); (c) chemical disinfectants incorporation did not reduced. / Doutor
5

Influência de diferentes protocolos de jateamento na resistência à flexão e na estabilidade estrutural de uma cerâmica policristalina de zircônia tetragonal parcialmente estabilizada com ítria /

Souza, Rodrigo Othávio de Assunção e. January 2009 (has links)
Orientador: Marco Antonio Bottino / Banca: Luiz Felipe Valandro Soares / Banca: Eduardo Miyashita / Banca: Paulo Francisco Cesar / Banca: Carlos Augusto Pavanelli / Resumo: Este estudo avaliou o efeito de diferentes protocolos de jateamento na resistência à flexão biaxial e na estabilidade estrutural de uma cerâmica de Y-TZP. Para tanto, duzentos e dezesseis discos sinterizados de Y-TZP (Lava, 3M ESPE) (ISO 6872, diâmetro: 15 mm, espessura: 2 mm) foram confeccionados pelo fabricante. Para o ensaio de resistência à flexão, 180 discos (n=10) foram divididos entre 18 grupos de acordo com os fatores "tipo de partícula (Al2O3- 50 e 110μm; SiO2- 30 e 110 μm)", "pressão (2,5 e 3,5 bar)" e "ciclagem mecânica (CM) (com e sem)". O jateamento foi realizado a uma distância de 10 mm e com duração de 20 s: Gr1- Controle - (sem tratamento de superfície); Gr2- Al2O3 50 μm/2,5 bar; Gr3- Al2O3 50 μm/3,5 bar; Gr4- Al2O3 110 μm/2,5 bar; Gr5- Al2O3 110 μm/3,5 bar; Gr6- SiO2 30 μm/2,5 bar; Gr7- SiO2 30 μm/3,5 bar; Gr8- SiO2 110 μm/2,5 bar; Gr9- SiO2 110 μm /3,5 bar. Os grupos Gr10 a Gr18 são respectivamente os grupos anteriores submetidos à CM (100.000 ciclos, 50 N, 4 Hz, água 370C. Em seguida todas as amostras foram submetidas ao ensaio de resistência à flexão biaxial (ISO 6872) em máquina de ensaio universal (EMIC, 1 mm/min). Após ensaio de flexão, os dados obtidos (MPa) foram submetidos ao teste de Dunnett (5%) e à Análise de Variância (3 fatores). Para determinar a quantidade e profundidade de possíveis transformações de fase da zircônia (t→m) induzida pelo jateamento e/ou pela ciclagem mecânica, foi realizada a análise de difração de Raios-X em vinte amostras (n=2) dos grupos Gr1 ao Gr9 e Gr18, antes e após tratamento térmico (ciclo de queima da VM9/Vita). Os resultados demonstraram que todos os protocolos de jateamento promoveram um aumento significativo da resistência à flexão da cerâmica de Y-TZP em relação... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of different air-particle-abrasion protocols on the biaxial flexural strength and on the structural stability of Y-TZP ceramic. Disc shaped (ISO 6872, Ø: 15 mm, thick: 2 mm) sintered zirconia specimens (N=216) were obtained from the manufacturer (Lava, 3M ESPE). To the flexure test 180 discs (n=10) were divided among the groups according to the factors "particle (Al2O3 50 and 110μm; SiO2 30 and 110 μm)", "pressure (2.5 and 3.5 bar)" and "mechanical cycling (MC)(with and without)". The air-particle-abrasion protocols were performed with 10 mm of distance and duration of 20 s: Gr1- Control - (without air-particle-abrasion); Gr2- Al2O3 50 μm/2,5 bar; Gr3- Al2O3 50 μm/3,5 bar; Gr4- Al2O3 110 μm/2,5 bar; Gr5- Al2O3 110 μm/3,5 bar; Gr6- SiO2 30 μm/2,5 bar; Gr7- SiO2 30 μm/3,5 bar; Gr8- SiO2 110 μm/2,5 bar; Gr9- SiO2 110 μm /3,5 bar. The groups Gr10 to Gr18 are those groups before submitted to MC, respectively (100.000 cycles; 50 N, 4 Hz, water 370C). After, all specimens were tested for biaxial flexural strength (ISO 6872) in a universal testing machine (EMIC). After, all specimens were tested for biaxial flexural strength (ISO 6872) in a universal testing machine (EMIC). The data were submitted to statistical tests ANOVA and Dunnett (5%). To determine the percentage and deep of possible zirconia transformations (te mo) after the air-particle-abrasion protocols and/or MC, the X-Ray diffraction was performed on 20 samples (n=2) from the groups Gr1 to Gr9 and Gr18, before and after thermal treatment (VM9/Vita firing cycle). The results showed that all air-particle-abrasion protocols increased significantly the flexure strength of the Y-TZP ceramic compared to the negative Control... (Complete abstract click electronic access below) / Doutor
6

Avaliação da força de preensão palmar plena e pulpo-lateral : relação com a antropometria da mão e posições de trabalho /

Vidrich Filho, Hélio. January 2005 (has links)
Orientador : José Carlos Plácido da Silva / Banca: José Antonio Galbiatti / Banca: Luis Carlos Paschoarelli / Resumo: O presente trabalho avaliou 60 indivíduos, sem patologias, 30 homens e 30 mulheres, entre 17 e 70 anos, totalizando 120 membros superiores. Elaborou-se um protocolo, a fim de se avaliar a força de preensão palmar plena, medida com o Dinamômetro JAMAR®, e a força de preensão pulpo-lateral, medida com o Medidor de Pinça B&L, correlacionando-as com o gênero, idade, posições dos membros superiores e medidas antropométricas da mão. Constatou-se que ambas as forças de preensão foram maiores no gênero masculino do que no gênero feminino, assim como, as medidas antropométricas das mãos. Levando-se em conta a correlação das forças com as posições dos membros superiores, nas quais foram avaliadas as forças não se encontrou correlação estatisticamente significativa em nenhuma das posições, porém, observou-se correlação com algumas medidas antropométricas das mãos, como largura da mão, comprimento do polegar e do dedo médio, assim como da mão. Portanto as medidas antropométricas devem ser consideradas em uma avaliação clínica e/ou ergonômica. / Abstract: The present research evaluated 60 people without any current pathologies, 30 male and 30 female whose age range went from 17 to 70 years old making up a total of 120 upper limbs. A protocol was created aiming to evaluate full grip strength, measured with JAMAR® Dynamometer, and lateral pulp grasp measured with B&L Pinch, relating them to gender, age, upper limbs positions and anthropometrical hand measurements. It has been noticed that both grip strengths were larger with males rather than females as well as the anthropometrical hand measurements. Taking into consideration the relation of the forces with the upper limbs positions in which the forces were evaluated, no meaningful statistical relation was found in any of the positions, however, a relation with some anthropometrical hand measurement were noticed such as hand width, thumb and middle finger length, as well as the hand’s. Therefore, the anthropometrical hand measurements shall be regarded towards a clinical and/or ergonomic evaluation. / Mestre
7

Estimadores da resistência mecânica característica da madeira /

Pinheiro, Wendell, 1976- January 2011 (has links)
Orientador: Adriano Wagner Ballarin / Banca: José Raimundo de Souza Passos / Banca: Luiz Antonio Targa / Resumo: A qualificação da madeira para uso estrutural é feita com base na sua resistência característica à compressão paralela às fibras. A partir de valores individuais de resistência à compressão paralela de corpos de prova de uma amostra representativa do lote de madeira, a resistência característica é avaliada com estimador específico, proposto pela NBR 7190 (ABNT, 1997). Com o valor da resistência característica, o lote de madeira é classificado em classes de resistência (três classes distintas para madeiras de coníferas e quatro classes distintas para madeira de folhosas) que variam de 20 MPa a 60 MPa. Lotes de madeira com maior valor de resistência característica levam, na maioria das vezes, à otimização dos projetos estruturais. O objetivo principal deste trabalho foi avaliar a eficiência de vários estimadores da resistência característica de lotes de madeira de distintas procedências, gêneses e idades das árvores, com base em suas aplicações em amostras de diferentes tamanhos amostrais. Para o estudo foram utilizados lotes de resultados de resistência mecânica da madeira de diversos conjuntos de dados, abrangendo resistências à compressão paralela às fibras e resistências ao cisalhamento de madeiras nativas e de reflorestamento, coníferas e folhosas. Com uso do software estatístico SAS, para cada lote sortearam-se repetidamente amostras, variando-se os tamanhos amostrais e, a partir dos valores de resistência dos indivíduos de cada amostra foram calculadas as resistências características dos lotes. Tomando-se a resistência característica do lote (aqui assumido como população) como referencial, foi avaliada comparativamente a eficiência de cada estimador, com base no erro quadrático médio e no desvio da estimativa. 2 Os resultados mostraram que o estimador... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In Brazil, lumber classification for structural purposes is based on its characteristic strength in compression parallel to grain. From individual values of strength in compression parallel obtained from specimens of a sample, characteristic strength is evaluated with a particular estimator proposed by the standard NBR 7190 - Design of wood structures (ABNT, 1997) for general usage (all the mechanical properties). With this characteristic strength, lumber lot is classified into classes of strength (three different classes of coniferous woods and four different classes for hardwood) ranging from 20 MPa to 60 MPa. Lumber lots with higher characteristic strength leads, in general, to a design optimization. The main objective of this study was to evaluate the efficiency of several estimators of characteristic strength of lumber lots with distinct origin, genesis and ages, based on their application in samples with different size. Lots of results of strength in compression and in shear parallel to grain of conifers and hardwood from native and reforested plantation were used. Using SAS - Statistical Analysis System - specimens were randomly sampled from each lot - varying sample size from 6 to 42 specimens - from which the characteristic strength of the lot was calculated each time based on the estimators. Taking as referential the characteristic strength of the full lot (assumed as the population), comparative efficiency of the estimators were analyzed based on MSE (mean squared error) and deviation of the estimation. Results showed that the estimator proposed by NBR 7190(ABNT, 1997) was not the more efficient in all cases. For compression and shear parallel to grain, best estimations of characteristic strength were obtained with the estimator that uses lots central tendency and dispersion parameters in its formulation... (Complete abstract click electronic access below) / Mestre
8

Avaliação da resistência de união entre dentes artificiais e resinas acrílicas para base protética. Efeito de termociclagem /

Marra, Juliê. January 2007 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Débora Barros Barbosa / Banca: Renata Garcia Fonseca / Resumo: O estudo avaliou a resistência de união entre dentes artificiais e resinas acrílicas para base protética e o efeito da termociclagem. Para isso foram utilizadas três marcas comerciais de dentes artificiais de resina acrílica (Biotone, Trilux e Ivoclar) e quatro de resinas acrílicas para base protética, sendo duas termopolimerizáveis por banho de água quente (Lucitone 550 e QC-20), uma polimerizada por meio da energia de microondas (Acron MC) e uma fotopolimerizável (Versyo.com). Vinte espécimes foram confeccionados para cada combinação de dente artificial e resina acrílica e divididos em 2 grupos (n=10) nas seguintes condições experimentais: sem a ação da termociclagem (grupo controle) e com a ação da termociclagem. Os espécimes dos grupos com termociclagem foram submetidos 5000 ciclos com temperatura variando entre 4º e 60ºC e tempo de imersão de 30 segundos em cada. Em seguida, os espécimes foram submetidos ao ensaio mecânico de cisalhamento em máquina universal a uma velocidade de 1mm/min. Os dados foram submetidos à análise de variância a três fatores seguida pelo teste de Bonferroni para comparações múltiplas (a=0,05). Os resultados demonstraram que a termociclagem reduziu significantemente os valores médios de resistência de união da resina acrílica Lucitone 550 quando associada aos dentes Biotone e Trilux e com a resina Versyo.com e os dentes Ivoclar P<0,05). E que as médias de resistência de união das resinas acrílicas Acron MC e Lucitone 550 quando associadas aos dentes Ivoclar aumentaram significantemente após a ação da termociclagem (P<0,05). Conclui-se que algumas combinações de dente artificial e resina acrílica podem ser mais afetadas pela ação da termociclagem, e esses efeitos variam de acordo com os materiais selecionados. / Abstract: The purpose of this in vitro study was to evaluate the bond strength of denture base resins to acrylic denture teeth and the effect of the thermocycling. Three acrylic denture teeth (Biotone, Trilux and Ivoclar) were chosen for bonding to four denture base resins: one microwave-polymerized (Acron MC), two heat-polymerized (Lucitone 550 and QC-20) and one light-polymerized (Versyo.com). Twenty specimens were produced for each denture base/acrylic denture tooth combination and were divided into 2 groups (n=10) as follows: without thermocycling (control groups) and thermocycled groups that were submitted to 5,000 cycles between 4º and 60ºC with a dwell time of 30 seconds in each bath. Shear strength tests (MPa) were performed with a universal testing machine at a crosshead speed of 1 mm/min until fracture. Statistical analysis of the results was carried out with 3-way ANOVA and Bonferroni's multiple comparisons post hoc analysis for test groups (a=.05). A significant interaction between denture base resin, acrylic denture teeth and thermocycling (P<.001) was observed. The shear bond strengths of Lucitone 550/Biotone, Lucitone 550/Trilux and Versyo.com/Ivoclar specimens were significantly decreased by thermocycling compared with the corresponding control groups (P<.05). The shear bond strengths of Acron/Ivoclar and Lucitone/Ivoclar specimens significantly increased after thermocycling (P<.05). Some acrylic tooth/denture base resin combinations can be more affected by thermocycling; the effects vary based upon the materials used. / Mestre
9

Comparação da análise miográfica sonora com a força muscular /

Cunha, Marcos Guimarães de Souza. January 2010 (has links)
Orientador: Araildo Lima da Silva / Banca: Mauro Gonçalves / Banca: Renato Sousa Almeida / Banca: Mauro Cesar Tavres de Souza / Banca: João Alberto Oliveira / Resumo: Os músculos estriados esqueléticos, através de suas propriedades de contratilidade, extensibilidade e elasticidade, formam o principal motor das articulações nos seres humanos, através da tração exercida no tendão ou na aponeurose. Os músculos controlam, coordenam e realizam os movimentos articulares. A força produzida pelos músculos pode ser estimada através das alavancas realizadas pelo membro, considerando-se o torque de cada força, quando o músculo se contrai, parte da energia desta contração será dissipada na forma de som. A presente pesquisa tem como objetivo principal desenvolver um sistema para avaliar o sinal acústico muscular e comparar com a força produzida em uma célula de carga pela alavanca do membro superior. Os músculos selecionados para esta pesquisa foram os flexores do cotovelo, pela facilidade de acesso e de posicionamento. Foram coletados os sinais acústicos e do esforço realizado de 16 indivíduos de ambos os sexos, sendo 9 do sexo masculino e 7 do sexo feminino, saudáveis, com idade entre 18 e 35 anos, sem histórico de doenças neurológicas, cardiovasculares, não praticantes de atividade física que produzisse a hipertrofia dos músculos flexores do cotovelo. Foi desenvolvido um sistema para avaliação do sinal acústico muscular utilizando como sensor um estetoscópio adaptado com um microfone, simultaneamente à aquisição do torque produzido pelos flexores do cotovelo e avaliado por uma célula de carga. A presente pesquisa permitiu identificar que as principais freqüências acústicas da contração dos flexores do cotovelo estão na faixa de 10 a 15 Hz quando a contração equivale de 75 a 100% da força máxima para o sexo feminino e de 50 a 100 % da força máxima para o sexo masculino e na faixa de 5 a 10 Hz quando a contração equivale de 25 a 50 % da força máxima para o sexo feminino e 25 % da força máxima para o sexo masculino... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Striated skeletal muscles, through their properties of contractility, extensibility and elasticity, are the main driver of the joints in humans, through the traction exerted on the tendon or aponeurosis, muscle control, coordinate and carry out joint movements. The force produced by muscles can be estimated using from the levers held by the member, considering the torque of each force when the muscle contracts, this contraction of the energy is dissipated in the form of sound. The main objective of this research is to develop a system to evaluate the acustic signal and compare it with the muscular force produced in a load cell by the lever of the upper limb. The muscles selected for this research were elbow flexors, because of the easy access and positioning. Acoustic signals were collected and the effort made to 16 individuals of both sexes. We analyzed 9 male and 7 female, healthy and aged between 18 and 35 years old with no history of neurological and cardiovascular disease and not engaged in physical activity that could develop hypertrophy of the elbow flexor muscles. A system was developed for evaluation of the acoustic signal using muscle as a sensor adapted stethoscope with a microphone, simultaneously with the aquisition of the torque produced by the elbow flexor and evaluated by a load cell. This research has identified that the main acoustic frequencies of contraction of the elbow flexors are in the range of 10 to 15 Hz when the contraction equals 75 to 100% of maximum force for females and 50 to 100% of maximum force to males and in the range 50 to 10 Hz when the contraction equals 25 to 50% of maximum force for females and 25% of maximum force for males, as well as the correlation of the acoustic signals of males female with a coefficient less than 4. It was concluded that the acoustic signal muscle has specific characteristics for different levels of intensity of muscle... (Complete abstract click electronic access below) / Doutor
10

Influência do tipo de preparo e sistema adesivo na resistência de união à dentina bovina /

Silva, Melissa Aline da. January 2010 (has links)
Resumo: Este estudo avaliou a resistência de união entre dentina bovina e três sistemas adesivos: um de condicionamento total e dois autocondicionantes, variando-se o tipo de preparo da dentina. Foram utilizados 108 dentes bovinos onde as raízes foram removidas e a dentina coronária vestibular foi exposta. As superfícies foram preparadas com os seguintes métodos: pontas diamantadas de granulação média em turbina de alta rotação, pontas CVD acopladas em aparelho de ultra-som e laser Er:YAG. Os grupos foram subdivididos para aplicação dos seguintes sistemas adesivos de acordo com as recomendações do fabricante: Clearfil SE Bond (Kuraray), Adper SE Plus (3M ESPE), autocondicionantes, e Adper Single Bond 2 (3M ESPE), de condicionamento ácido total. Os espécimes foram restaurados com resina composta Filtek 250 (3M ESPE) com espessura de 4 mm. A resina foi inserida em incrementos de 2 mm e fotopolimerizada por 20 s. Em seguida, os espécimes foram armazenados em água destilada a 37 °C por 24 h e então seccionados em formato de palito com aproximadamente 1mm2 de área na interface adesiva. Foi realizado o teste de microtração em máquina de ensaio universal com velocidade de 1.0 mm/min. Os resultados foram submetidos aos testes estatísticos de análise de variância paramétrica de 2 fatores (ANOVA) e o teste de Tukey empregando um nível de significância de 5% (p<0,05). Espécimes adicionais foram preparados para observação em microscópio eletrônico de varredura. Os resultados mostraram que a ponta CVD obteve menores valores de resistência adesiva, enquanto a ponta diamantada e o laser obtiveram valores semelhantes, porém mais elevados. O sistema adesivo Single Bond obteve valores equivalentes ao Adper SE Plus e significativamente diferentes quando comparados ao sistema adesivo Clearfil SE Bond . O estudo concluiu que o método de preparo e o tipo de sistema adesivo influenciaram na resistência de união / Abstract: The aim of this study was to compare the microtensile bond strength of two self-etching adhesive systems and one total-etching, with different methods of dentin preparation. A hundred and eight bovine teeth, stored in freezer -18ºC, were used. The buccal face dentine was exposed and prepared with three different methods: Diamond tip (DT) with high speed; CVD tip with ultrasound advice (CVD) and Er:YAG laser (LA). Three different adhesive systems were used: Adper Single Bond 2 (SB) (3M ESPE), total etch; Adper SE Plus (AS) (3M ESPE) and Clearfil SE Bond (CS) (Kuraray), both self-etching. After dentin preparation, the adhesives systems were applied according to manufacturer's instructions. Blocks of composite resin (Filtek Z250 - 3M ESPE) with 4 mm high were prepared using the incremental technique. After storage in distilled water for 24h at 37ºC, serial mesio-distal and bucco-lingual cuts were made and stick-like specimens were obtained, with transversal section of 1,0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (Mpa) were subjected to ANOVA and Tukey tests (5%). The results showed lower bond strength in groups prepared with CVD tip. LA and DT groups obtained similar values of bond strength and higher than CVD. The adhesive systems SB and AS showed values higher than CS. It was concluded that the method of dentine preparation and adhesive system tested influenced in bond strength / Orientador: Rebéca Di Nicoló / Coorientador: Alessandra Bühler Borges / Banca: Marcelo José Strazzeri Bönecker / Banca: César Rogério Pucci / Mestre

Page generated in 0.0483 seconds