• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 12
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 38
  • 38
  • 17
  • 13
  • 11
  • 10
  • 9
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Arterial mechanics : noninvasive identification of constitutive parameters and residual stress /

Stålhand, Jonas, January 2005 (has links) (PDF)
Diss. Linköping : Univ., 2005.
12

Comparative in vivo and in vitro studies on the biomechanics of maxillary partial dentures a methodological and experimental study /

Fernandes, Cláudio Pinheiro. January 1998 (has links)
Thesis (doctoral)--Lunds Universitet, Malmö, Sweden, 1998. / Added t.p. with thesis statement inserted. Includes bibliographical references.
13

Comparative in vivo and in vitro studies on the biomechanics of maxillary partial dentures a methodological and experimental study /

Fernandes, Cláudio Pinheiro. January 1998 (has links)
Thesis (doctoral)--Lunds Universitet, Malmö, Sweden, 1998. / Added t.p. with thesis statement inserted. Includes bibliographical references.
14

Burnout em cuidadores formais de idosos de uma instituição de longa permanência

Rosa, Danielle Magosso Milani 21 March 2018 (has links)
Submitted by Suzana Dias (suzana.dias@famerp.br) on 2018-11-06T17:09:19Z No. of bitstreams: 1 DanielleMagossoMilaniRosa_dissert.pdf: 2469038 bytes, checksum: 8d1230a41ed81e25b7bb525b2077c06e (MD5) / Made available in DSpace on 2018-11-06T17:09:19Z (GMT). No. of bitstreams: 1 DanielleMagossoMilaniRosa_dissert.pdf: 2469038 bytes, checksum: 8d1230a41ed81e25b7bb525b2077c06e (MD5) Previous issue date: 2018-03-21 / The care practice comprises some situations that can lead to stress, causing damage to health, as well as to the quality of care provided. Burnout syndrome is related to this working stress. It is found mainly in workers who perform care activities; characterized by the triad: low professional achievement, emotional exhaustion and depersonalization. Objectives: To investigate the presence of Burnout Syndrome in formal caregivers of elderlies from a long-staying institution ; to correlate with physical activity level, quality of life, anxiety and depression. Method: This is a descriptive, cross-sectional, qualitative and quantitative study, with a convenience sample of 82 caregivers. Materials: Demographic questionnaire, Maslach Burnout Invetory - Human Services Survey, Hospital Anxiety and Depression Scale, International Physical Activity Questionnaire - short version and Medical Outcomes Study-36-Item Short- Form Health Survey. Results: A total of 100% of female caregivers, mean age of 37.7 years and married were observed. Most had high school education, 67.1% had no specialization in the area of care. According to the evaluation of Burnout Syndrome; 64.6% presented low score for the emotional exhaustion domain and 78.5% low score for the depersonalization domain, and 58.2% high score for the professional achievement domain; 63% and 76% unlikely levels of anxiety and depression respectively. 60% moderate levels of physical activity, followed by 39% with low level. Regarding quality of life, the domain of pain presented the lowest score. There was no statistical difference when comparing MBI-HSS between day and night shifts. The correlation between IPAQ and MBI-HSS has not also not presented statistical difference. When correlating the quality of life questionnaire with MBI-HSS, a correlation was found between the domain emotional exhaustion and vitality (-0.028), professional achievement and mental health (0.003), depersonalization with vitality (- 0.286) and mental health (-0.276). We did not find correlation between age and education with the MBI-HSS domains. Conclusion: The presence of Burnout Syndrome in this sample was considered low and the correlation between Burnout and age, education, anxiety and depression have not presented statistical evidence. / A prática do cuidado é permeada de situações que podem conduzir ao estresse, causando prejuízos à saúde, bem como, à qualidade do cuidado prestado. A Síndrome de Burnout está relacionada a esse estresse laboral, presente, principalmente, em trabalhadores que realizam atividade assistencial e caracteriza-se pela tríade: baixa realização profissional, exaustão emocional e despersonalização. Objetivo: investigar a presença da Síndrome de Burnout em cuidadores formais de idosos de uma instituição de longa permanência; correlacionar com nível de atividade física, qualidade de vida, ansiedade e depressão. Método: trata-se de um estudo descritivo, transversal, qualitativo e quantitativo, composto por uma amostra de conveniência de 82 cuidadores. Materiais: questionário sócio demográfico, Maslach Burnout Invetory – Human Services Survey, Escala de Ansiedade e Depressão Hospitalar, Questionário Internacional de Atividade Física –versão curta e Medical Outcomes Study-36-Item Short- Form Health Survey. Resultados: encontramos 100% dos cuidadores do sexo feminino, com média de idade de 37,7 anos, casada. A maioria com segundo grau completo, 67,1% sem especialização na área de cuidados. Na avaliação da Síndrome de Burnout 64,6% apresentaram score baixo para o domínio exaustão emocional e 78,5% score baixo para o domínio despersonalização e 58,2% score alto para o domínio realização profissional. 63% e 76% níveis improváveis de ansiedade e depressão respectivamente. 60% níveis moderados de atividade física, seguido de 39% com nível baixo. Em relação a qualidade de vida, o domínio com menor pontuação foi o domínio dor. Não houve diferença estatística ao comparar MBI-HSS entre os turnos diurno e noturno. A correlação entre IPAQ e MBI-HSS também não apresentou diferença estatística. Ao correlacionar o questionário de qualidade de vida com MBI-HSS, encontrou-se correlação entre o domínio exaustão emocional e vitalidade (-0,028), realização profissional e saúde mental (0,003), despersonalização com vitalidade (-0,286) e com saúde mental (-0,276). Não encontramos correlação entre idade e escolaridade com os domínios do MBI-HSS. Conclusão: a presença da Síndrome de Burnout nesta amostra foi considerada baixa e a correlação entre Burnout e idade, escolaridade, ansiedade e depressão não apresentaram evidência estatística.
15

The effect of inhibitor and initiator concentration on degree of conversion, flexural strength and polymerization shrinkage

Shaabin, Maram, January 2009 (has links)
Thesis (M.A.)--Indiana University School of Dentistry, 2009. / Title from PDF t. p. (viewed Mar. 30, 2010) Advisor(s): Gabriel Tien-Min Chu, Chair of the Research Committee, Melvin R. Lund, Bruce A. Matis, Carlos Gonzalez-Cabezas, Michael A. Cochran. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 79-87).
16

Comportamento sob fadiga de restaurações cerâmicas ultrafinas cimentadas adesivamente em preparos correspondentes aos dentes posteriores /

Abu-Izze, Fernanda de Oliveira. January 2017 (has links)
Orientador: Marco Antonio Bottino / Coorientadora: Lilian Costa Anami / Banca: Lafayette Nogueira Junior / Banca: Alberto Alvarenga de Oliveira / Resumo: A fim de investigar a vida em fadiga, modos de falha e distribuição de tensões de restaurações ultrafinas parciais, tipo tabletop, em diferentes cerâmicas, sessenta preparos padronizados foram confeccionados em resina epóxi G10 e foram cimentadas adesivamente restaurações cerâmicas de silicato de lítio reforçado com zircônia (ZLS, Vita Suprinity- Vita Zahnfabrik), ou restaurações de cerâmica híbrida (PIC, Vita Enamic- Vita Zahnfabrik), em 0,5 ou 1 mm de espessura. O mesmo protocolo de ciclagem foi aplicado para todos os espécimes, que consistiu em 5.000 ciclos a 200 N, seguidos de 450 N ciclos até a fratura dos espécimes ou a suspensão do teste após 1,5 x 106 ciclos. A carga axial foi realizada com uma freqüência de 4 Hz no equipamento Biocycle V2 (Biopdi, São Carlos, SP), com amostras imersas em água. A presença de falhas e/ou fraturas foi verificada a cada 2,5 x 105 ciclos e a análise de sobrevivência foi realizada com o número de ciclos em que cada espécime falhou. Os espécimes foram avaliados usando estereomicroscópio e microscopia eletrônica de varredura (MEV). Após a tabulação de dados, foram realizados Kaplan-Meier e Mantel-Cox (Teste Log Rank), seguindo de comparação múltipla aos pares, todos com nível de significância de 5% e análise de Weibull. Através da análise tridimensional de elementos finitos, a distribuição de tensões máximas principais (TMP) nas tabletop oclusais posteriores foram avaliados comparando diferentes tipos de substrato (G10, esmalte/dentina, esma... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To investigate the fatigue life, failure modes and stress distribution of partial ultrafine restorations for posterior teeth in different ceramics, sixty standard tabletop preparations in epoxy resin G10 received lithium silicate based zirconia reinforced (ZLS, Vita Suprinity- Vita Zahnfabrik), or hybrid ceramic (PIC, Vita Enamic- Vita Zahnfabrik), restorations in .5 or 1 mm thickness bonded using resin cement. The same cycling protocol was applied for all specimens that consisted of 5.000 cycles at 200 N followed by 450 N cycles until the specimens' fracture or the suspension of the test after 1.5 x 106 cycles. Axial load was carried out with a 4 Hz frequency in Biocycle V2 equipment (Biopdi, São Carlos, SP), with samples immersed in water. Presence of cracks and/or fractures was checked with every 2,5 x 105 cycles and the survival analysis was performed using the number of cycles in which each specimen failed. All specimens were evaluated using stereomicroscope and scanning electron microscopy (SEM). After data tabulation, Kaplan-Meier and Mantel-Cox (Log Rank test) analysis were performed, followed by multiple pairwise comparison, all with a significance level of 5%, and Weibull analysis. Through tridimensional finite element analysis, stresses distribution and maximum principal stresses in the posterior occlusal veneers were evaluated comparing different types of substrate (G10, enamel/dentin, enamel), thicknesses and ceramic materials. Zirconium-reinforced lithium silica... (Complete abstract click electronic access below) / Mestre
17

Estudo comparativo da resistência mecânica cíclica e linear entre placas pré-dobradas e dobradas manualmente para avanço maxilar em cirurgia ortognática / Comparative study of cyclic and linear mechanical resistance of prebent and manually bent plates used for maxillary advancement in orthognathic surgery

Moura, Andrezza Lauria de, 1982- 25 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T11:10:00Z (GMT). No. of bitstreams: 1 Moura_AndrezzaLauriade_D.pdf: 2051584 bytes, checksum: 4113d876cae0533f95488619a05aa704 (MD5) Previous issue date: 2014 / Resumo: O propósito no estudo foi avaliar comparativamente, através de teste de carregamento linear e cíclico, placas pré-dobradas e dobradas manualmente para avanço maxilar em cirurgia ortognática. Os grupos foram divididos em: Grupo I com placas pré-dobradas para avanço maxilar de 5mm, fixadas em blocos de poliuretano para o teste linear e blocos de alumínio para o teste cíclico; e grupo II, com placas dobradas manualmente simulando avanço maxilar de 5mm, fixadas em blocos de poliuretano e alumínio. Os testes de carregamento linear foram realizados com 8 amostras em cada grupo e com auxílio da máquina para ensaio universal mecânica Instron® 4411 até a falha do material. Já o teste cíclico foi realizado com 5 amostras em cada grupo através de uma máquina para ensaio universal Instron® E3000 e foram submetidas à carga de 12N a 120N, frequência de 3 Hz até a fratura da placa ou parafuso e com o número máximo de 500.000 ciclos. As médias e desvio padrão foram avaliadas através dos testes t-Student e Mann-Whitney em nível de significância de 5% para o teste linear e medianas através do teste Mann-Whitney para o teste cíclico. Os resultados do teste mecânico linear mostraram que não houve diferença estatística entre os grupos de placas pré-dobradas e dobradas manualmente, quando comparados em relação a carga de pico (p=0.09) e deslocamento de pico (p=0.63). Já o teste cíclico apresentou diferença estatística entre os grupos quanto ao número de ciclos, onde o grupo de placas pré-dobradas atingiu o limite de 500.000 ciclos sem fratura e o grupo de placas dobradas manualmente fraturaram em uma média 94.737 ciclos (p=0.008). A resistência mecânica in vitro entre os grupos de placas pré-dobradas e as dobradas manualmente não alterou com a confecção de dobras no teste de carregamento linear, porém, a confecção das mesmas pode ter criado microfraturas e fragilizações que, com o teste de ciclagem, causaram fratura prematura das placas com dobras manuais / Abstract: The purpose of the study was to comparatively evaluate, through linear load testing and cyclic loading test, prebent plates and plates bent manually to maxillary advancement in orthognathic surgery. The groups were divided into Group I with prebent plates for 5mm maxillary advancement, fixed in polyurethane blocks for linear test and aluminum blocks for cyclic test; and group II, with eight plates bent manually for 5mm maxillary advancement, fixed in polyurethane and aluminum blocks. Linear loading tests were performed with eight samples in each group through a mechanical universal testing machine Instron ® 4411, until failure of the material. The cyclic tests were performed with five samples in each group through a mechanical universal testing machine Instron ® E3000, where the samples were subjected to load of 12N to 120N and frequency of 3 Hz until plate or screw fracture, whit maximum number of 500,000 cycles. Means and standard deviations were evaluated by applying the Student t test and Mann-Whitney test at a significance level of 5% for linear loading and medians by Mann-Whitney test for cyclic loading. The results of linear mechanical testing showed no statistical difference between the groups pre-folded cards and folded manually compared peak load (p = 0.09) and peak displacement (p = 0.63). The cyclic test showed statistical difference between the groups, where the group of prebent plates reached the limit of 500,000 cycles without fracture and the group of manual bent plates fractured at an average of 94.737 cycles (p=0.008). The mechanical resistance in vitro among groups of prebent plates and plates bent manually does not change with the confection of bends in the linear loading test; however, the bends may have created microfractures and embrittlements that with the cyclic test, caused premature fracture of the plates / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutora em Clínica Odontológica
18

Avaliação mecânica in vitro e análise fractográfica de duas marcas comerciais nacionais de sistema de fixação 2,0mm com travamento de parafusos em fraturas simuladas de corpo mandibular / Mechanical and fractographic analysis of two national brands of 2.0mm locking fixation systems in simulated mandibular body fracture

Correia Medeiros, Raquel, 1986- 23 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T02:59:43Z (GMT). No. of bitstreams: 1 CorreiaMedeiros_Raquel_M.pdf: 1506622 bytes, checksum: 7e7760f3ed374300679a2cb781f5ca71 (MD5) Previous issue date: 2013 / Resumo: Este trabalho teve como objetivo de avaliar comparativamente a resistência de duas marcas de sistema de fixação de 2,0 mm com sistema de travamento de parafusos em hemimandíbulas de alumínio com fratura simulada de corpo mandibular. E também, realizar a análise fractográfica das placas utilizadas no estudo acima, através de Microscopia Eletrônica de Varredura (MEV). Quatro hemimandíbulas em alumínio com seccionamento linear simulando uma fratura de corpo mandibular foram utilizadas como substrato, fixadas de acordo com duas técnicas de fixação de duas marcas nacionais Tóride® (Tóride Indústria e Comércio Ltda. - Mogi Mirim, São Paulo - Brasil) e Traumec® (Traumec - Tecnologia e Implantes Ortopédicos Imp. e Exp. Ltda.- Rio Claro, São Paulo- Brasil) e divididas em dois grupos. O grupo I foi fixado com uma placa de quatros furos, com quatro parafusos de 6 mm na zona de tensão e uma placa de 4 furos, com 4 parafusos de 10 mm na zona de compressão e o grupo II foi fixado com uma placa de 4 furos com 4 parafusos de 6 mm na zona neutra. Para cada grupo foram utilizadas cinco amostras de cada marca comercial. As hemimandíbulas foram submetidas a testes de carregamento linear vertical por uma unidade de testes mecânicos Instron 4411(Instron Corp, Norwood, MA) para registro da carga de pico e da carga nos deslocamentos de 3 mm, 5 mm e 7 mm. As médias e o desvio padrão foram avaliados aplicando-se a Análise de Variância em nível de significância de 5%. Após os testes mecânicos, não houve diferença estatisticamente significante entre as marcas, tanto no grupo I quanto no grupo II, em relação às cargas suportadas no deslocamento de 3 mm e 5mm, nem entre as cargas de pico, havendo diferença apenas no deslocamento de 7 mm. De uma maneira geral, as placas Tóride® suportaram uma carga maior nos dois grupos. A superfície de fratura analisada no MEV apontou para uma fratura do tipo dúctil, normalmente encontrada em corpos de ensaio de tração de materiais dúcteis, como o titânio. Não foram observados em nenhuma superfície de fratura quaisquer indícios de falha por alteração na estrutura ou na composição do material / Abstract: This study aimed to comparatively evaluate the resistance of two brands of rigid fixation system with 2,0 mm locking system in hemimandibles of aluminum with simulated fracture of the mandibular body. Also, perform fractographic analysis of the same, by Scanning Electron Microscopy (SEM). Four hemimandible of aluminum with a sectioning linear simulating fracture of mandibular body were used as substrate and fixed according to two techniques for two national brands Tóride® (Tóride Indústria e Comércio Ltda. - Mogi Mirim, São Paulo - Brazil) and Traumec® (Traumec - Orthopedic Implants and Technology Imp. e Exp Ltda. - Rio Claro, São Paulo, Brazil). The techniques were: two 4- hole locking miniplate applied at the superior and inferior borders and one 4-hole locking miniplate applied in neutral zone. The samples was subjected to linear vertical loading in the canine region in an mechanical testing unit Instron 4411 (Instron Corporation, Norwood, MA) and the peak load and load displacement in 3 mm, 5 mm and 7 mm were recorded. Averages and standard deviations were evaluated by applying the analysis of variance at a significance level of 5%.After mechanical testing, there was no statistically significant difference between the brands, both in group I and group II, in relation to the load supported in the displacement of 3 mm and 5 mm, or between peak loads. The only difference between the brands, for both groups, was the load in the displacement of 7 mm. In general, the plates Toride supported a greater load in both groups. The fracture surface examined under SEM indicated a ductile fracture, usually found in bodies testing of ductile materials such as titanium. Were not observed, in any fracture surface, any evidence of failure by altering the structure or composition of the material / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestra em Clínica Odontológica
19

Efeito da ciclagem mecânica e da técnica de fundição sobre o desajuste marginal, tensão e torque de afrouxamento de infraestruturas de próteses múltiplas implantossuportadas = Effect of cyclic loading and casting technique over marginal fit, strain and loosening torque on frameworks of multi-unit implant-supported prostheses / Effect of cyclic loading and casting technique over marginal fit, strain and loosening torque on frameworks of multi-unit implant-supported prostheses

Bhering, Cláudia Lopes Brilhante, 1989- 21 June 2013 (has links)
Orientadores: Marcelo Ferraz Mesquita, Jessica Mie Ferreira Koyama Takahashi / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T08:00:41Z (GMT). No. of bitstreams: 1 Bhering_ClaudiaLopesBrilhante_M.pdf: 2599454 bytes, checksum: bd13164e8616791d20fc97e7001d9fc7 (MD5) Previous issue date: 2013 / Resumo: Este estudo teve como objetivo avaliar a influência do processo de fundição e da ciclagem mecânica sobre o desajuste marginal, tensão e torque de afrouxamento de próteses múltiplas implantossuportadas. Infraestruturas de prótese parcial fixa (PPF) suportada por dois implantes e prótese total fixa (PTF) suportada por cinco implantes foram enceradas usando cilindros de mini pilar totalmente calcináveis ou sobrefundidos (n=10). A partir das infraestruturas enceradas, os modelos de trabalho foram confeccionados utilizando análogos de implante (Hexágono Externo - 4.1mm) parafusados a mini pilares e um índex de gesso foi confeccionado utilizando análogos modificados de mini pilar. Quatro grupos foram obtidos de acordo com o tipo de prótese (PPF ou PTF) e cilindro protético (calcinável ou sobrefundido) avaliado. As infraestruturas foram fundidas em liga de CoCr e os parafusos apertados com 20Ncm (mini pilar) e 10Ncm (protético) utilizando torquímetro digital. Após 24 horas, o torque de afrouxamento e o desajuste inicial foram avaliados. O desajuste foi aferido por meio do teste do parafuso único. A análise de tensão foi realizada por meio de strain gauges colados na superfície dos análogos modificados, formando ¼ de ponte de Wheatstone. Os parafusos foram reapertados e as amostras submetidas a 106 de ciclos mecânicos (2Hz/280N). As mensurações finais foram realizadas e os resultados submetidos à Anova - 2 fatores/Teste de Tukey HSD e correlação de Pearson (?=0,05). Não houve diferença no desajuste para todos os intervalos de tempo e grupos avaliados no índex de gesso (p>0,05). As infraestruturas sobrefundidas apresentaram maior tensão que as obtidas com cilindros calcináveis (PPF: Inicial p=0,0047; Final p=0,0004; PTF: Inicial p=0,0476; Final p=0,0115). Não houve influência da ciclagem mecânica na tensão (p>0,05). No modelo de trabalho, as PPFs confeccionadas com cilindros calcináveis apresentaram maior desajuste que as sobrefundidas (Inicial: p=0,0005; Final: p=0,0007). As PTFs apresentaram desajuste similar (p>0,05). A ciclagem mecânica não influenciou o desajuste em ambos os modelos avaliados (p>0,05). Os parafusos de mini pilar das PTFs sobrefundidas apresentaram menor torque de afrouxamento que o grupo calcinável após a ciclagem mecânica (p=0,0024). Os parafusos protéticos dos grupos calcináveis apresentaram menor torque de afrouxamento que os sobrefundidos no tempo final (PPF: p=0,0013; PTF: p=0,0064). O torque de afrouxamento dos parafusos protéticos das PPFs calcináveis diminuiu após a ciclagem mecânica (p=0,0044). Correlação negativa foi observada entre o desajuste e o torque de afrouxamento dos parafusos protéticos (PPF: r=-0,49523 p=0,0012; PTF: r=-0,31423 p=0,0483). Não houve correlação entre o desajuste e a tensão (PPF: r=0,24 p>0,05; PTF: r=0,21 p>0,05). Conclui-se que o benefício do cilindro utilizado em relação à adaptação depende do tipo de prótese e componente sobre o qual o desajuste é avaliado. Próteses confeccionadas com cilindros sobrefundidos geram maior tensão e apresentam maior estabilidade dos parafusos protéticos. A ciclagem mecânica não influencia o desajuste e a tensão de próteses múltiplas, mas reduz o torque de afrouxamento em infraestruturas com maior desadaptação. Não existe correlação entre desajuste vertical decorrente da fundição e a tensão. Contudo, há correlação entre o desajuste marginal e o torque de afrouxamento dos parafusos protéticos mediante a ação de forças dinâmicas / Abstract: This study aimed to evaluate the influence of casting and cyclic loading on marginal misfit, strain and loosening torque of multiple implant-supported prostheses. Fixed partial dentures (FPD) frameworks supported by two implants and fixed full-arch dentures (FAD) frameworks supported by five implants were waxed using overcasted or calcinable mini abutment cylinders (n=10). The models were obtained with external hexagon implant analogs and mini abutments fixed to waxed frameworks. A plaster index was obtained using mini abutment modified analogs for strain gauge analysis. Four groups were obtained according to prosthesis (FPD or FAD) and cylinder (calcinable or overcasted) type. The frameworks were casted in CoCr alloy. The abutment and prosthetic screws were tightened with 20Ncm and 10Ncm, respectively, using digital torque meter. After 24 hours, initial loosening torque and marginal misfit were evaluated. The misfit readings were performed following the single screw test protocol. The prosthetic screws were tightened with 10Ncm and strain analysis performed by strain gauges bonded at the mini abutment analogs surface forming a ¼ of Wheatstone bridge. The screws were retightened and the samples submitted to 106 mechanical cycles (2Hz/280N). The final measurements were performed and the results submitted to 2 way - Anova/Tukey's HSD Test and Pearson Correlation Test (?=0.05). No difference was found in marginal misfit on all time intervals and groups on the plaster index (p>0.05). The frameworks manufactured with overcasted cylinders presented higher strain than calcinables ones, regardless of prosthesis type and time evaluated (FPD: Initial p=0.0047; Final p=0.0004; FAD: Initial p=0.0476; Final p=0.0115). No difference was observed in strain before and after cyclic loading (p>0.05). Considering the resin model, the calcinable FPD groups presented higher marginal misfit than overcasted ones (Initial: p=0.0005; Final: p=0.0007). Similar marginal misfit was noted among FAD groups (p>0.05). The cyclic loading did not affect the marginal misfit (p>0.05) in both evaluated models. The overcasted FADs abutment screws showed lower loosening torque than calcinable ones after cyclic loading (p=0.0024). The prosthetic screws of calcinable frameworks presented lower loosening torque than the overcasted at final measurement (FPD: p=0.0013; FAD: p=0.0064). After cyclic loading, the prosthetic screw loosening torque of calcinable FPDs decreased (p=0.0044). Negative correlation was observed between marginal misfit and loosening torque of prosthetic screws (FPD: r=-0.49523 p=0.0012; FAD: r=-0.31423 p=0.0483). No correlation was observed between misfit and strain (FPD: r=0.24 p>0.05; FAD: r=0.21 p>0.05). It is concluded for marginal fit, the benefit of the cylinder type depends on prosthesis design and component evaluated. Overcasted components generate higher strain and screw stability than totally calcinable ones. The cyclic loading did not influence misfit and strain of multiple-unit prostheses, but decreased the screw loosening torque in poorly fitted frameworks. There was no correlation between marginal misfit resulted from casting and strain induced on the system. There was correlation between marginal misfit and prosthetic screw loosening torque when submitted to cyclic loading / Mestrado / Protese Dental / Mestra em Clínica Odontológica
20

The effect of inhibitor and initiator concentration on degree of conversion, flexural strength and polymerization shrinkage stress on resin-matrix composite

Shaabin, Maram January 2009 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Polymerization shrinkage is one of the most significant problems associated with resin-matrix composite. Shrinkage results in contraction stress in the resin, leading to possible debonding in certain areas of the adhesive joint and potentially adversely affecting the bond strength. The reduction in the stress may improve the adaptation of the resin restoration, and decrease the problems that are associated with contraction stress, such as postoperative pain and recurrent caries. Recently, it has been found that varying the inhibitor concentration would reduce the polymerization shrinkage without affecting mechanical properties. In this study, we investigated the effects of varying the initiator and initiator levels on polymerization shrinkage stress, strength, and degree of conversion. An experimental composite was prepared by using a blend of BisGMA: UDMA: TEGMA (1:1:1 weight ratio) with 70 wt% silanated glass fillers. Four levels of inhibitors (BHT 0.0 %, 2%, 6%, 20%) and initiators (CQ 2%, 6%, 20%, 60%) were used (total of 16 combinations). A tensiometer was used to measure the polymerization contraction stress, contraction stress rate and gel time for each resin. FTIR was used to measure the degree of conversion. The flexural strength and flexural modulus were determined using the three-point bending test. Resin-matrix composite with 0.0-percent BHT and 2.0-percent CQ showed the highest contraction stress and stress rate and the shortest gel time, while resin-matrix composite with the 6.0-percent BHT and 6-percent CQ showed the lowest contraction stress and stress rate and the longest gel time. At an extremely high concentrations of CQ (20 percent and 60 percent) and high BHT concentration (20 percent) low degree of conversion values were observed. Overall, from the collected data, group F (2-percent BHT and 6-percent CQ) and G (6-percent BHT and 6-percent CQ) provide the most desirable combination of strength (above 80 MPa) and stress (below 3 MPa) are present as a potential dose combination range of CQ and BHT. In conclusion, the effect of inhibitors and initiators appears to change in different resin formulation. Increasing the levels of both the inhibitor and the initiator decrease the polymerization contraction stress and stress rate, and the impact on the conversion is unpredictable. In this study, we found a decrease in both the conversion value and depth of cure.

Page generated in 0.0813 seconds