• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 3
  • 1
  • Tagged with
  • 24
  • 24
  • 15
  • 15
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Pilares mistos de aço e concreto parcialmente revestidos: comportamento isolado, inserção em galpões industriais e comparativos com pilares de sistemas estruturais usuais

Serafim, Jorge Augusto 16 May 2013 (has links)
Made available in DSpace on 2016-06-02T20:09:19Z (GMT). No. of bitstreams: 1 5850.pdf: 3492179 bytes, checksum: a8bf8363cbcbb501bfa5251bc969c178 (MD5) Previous issue date: 2013-05-16 / Despite the great use in most developed countries, the composite structures have been little exploited in Brazil, including rare records the use of composite columns of steel and concrete partially coated in industrial sheds. The low-use leaves the impression of this being a structural solution viable. The aim of this work is to insert the composite columns of steel and concrete partially coated alternatively to the pillars of steel and precast, solutions commonly used in the composition of the structural system of industrial sheds. The development work was done to study the behavior of the isolated element and sizing criteria applicable, analysis of the structural design of systems where it can be employed and the phases of project highlighting, still, some steps involved in constructive phase of the industrial sheds. We analyzed the elements of 108 sheds with variation in the span between 20 to 50 m and height of 8 to 12 m. the porticos were designed considering coverage using steel beams with profile type I and type I section steel pillars, pillars of precast concrete with rectangular section, composite columns of steel and concrete partially coated consisting of metallic profile type I with filling of concrete between the tables. The porticoes were analyzed in 2nd order and scaled according to the specific Brazilian standards by comparing the results obtained between structural systems. Costs despite the difficulties have been raised for the central region of the State of São Paulo, where, after the composition were made comparisons between the solutions. The results obtained can realize that the use of composite columns of steel and concrete partially coated are perfectly viable with visa point economic values quite surprising, for the fact of being a solution less maid. The use of composite columns of steel and concrete partially coated is obviously viable as an alternative to the usual structural systems used in industrial sheds, comes in to advance contribution of Civil construction in General. / Apesar da grande utilização em países mais desenvolvidos, as estruturas mistas têm sido pouco exploradas no Brasil, inclusive com raros registros da utilização de pilar parcialmente revestido em galpões industriais. A pouca utilização deixa a impressão de esta não ser uma solução estrutural viável. O objetivo deste trabalho é inserir o pilar misto parcialmente revestido como alternativa aos pilares de aço e pré-moldados de concreto, soluções comumente empregados na composição do sistema estrutural de galpões industriais. Para o desenvolvimento do trabalho foi feito o estudo do comportamento do elemento isolado e dos critérios de dimensionamento aplicáveis, a análise da concepção estrutural dos sistemas onde possa ser empregado e das fases de projeto destacando, ainda, algumas etapas envolvidas na fase construtiva dos galpões. Foram analisados os elementos de 108 pórticos de galpão com variação do vão de 20 a 50 m e da altura de 8 a 12 m. Os pórticos foram projetados considerando cobertura utilizando-se vigas metálicas com perfil tipo I e, pilares metálicos de seção tipo I, pilares de concreto pré fabricado de seção retangular e, pilar misto parcialmente revestido constituído de perfil metálico tipo I com preenchimento de concreto entre as mesas. Os pórticos foram analisados em 2ª ordem e dimensionados de acordo com as normas brasileiras especificas comparando os resultados obtidos entre sistemas estruturais. Os custos apesar das dificuldades foram levantados para a região central do estado de São Paulo, onde, após a composição foram feitas as comparações entre as soluções. Pelos resultados obtidos pode-se perceber que a utilização dos pilares mistos de aço e concreto são perfeitamente viáveis com valores do ponto de visto econômico bastante surpreendentes pelo fato de ser uma solução pouco empregada. A utilização de pilares mistos de aço e concreto parcialmente revestidos é evidentemente viável como alternativa aos sistemas estruturais usuais utilizados em galpões industriais, vem contribuir em muito para o avanço da Construção Civil em geral.
22

Recomendações para o projeto e construção de estruturas com peças roliças de madeira de reflorestamento / Recommendations for design and construction of structures with roundwood from tree farms

Leandro Dussarrat Brito 18 May 2010 (has links)
Este trabalho tem por finalidade a proposta de um manual com recomendações para o projeto e construção de estruturas com peças roliças de madeira tratada, oriunda de madeiras de reflorestamento no Brasil. Para isso foram realizados estudos teóricos e experimentais de elementos estruturais e de ligações em madeiras utilizando peças roliças. Foram classificadas e caracterizadas peças roliças estruturais de madeira, visualmente e mecanicamente, e apresentadas diretrizes de projetos de pontes e de galpões com sistemas estruturais e construtivos em peças roliças de madeira de reflorestamento. Os resultados serão compilados em um manual de projeto e construção de estruturas de madeira utilizando peças roliças. O estudo teve, além disso, o objetivo de divulgar, por meio de catalogações em 124 fichas técnicas, alternativas na área de estruturas e na construção civil, utilizando madeiras com peças roliças, tais como estacas de fundações, passarelas, pontes, quiosques, galpões rurais, edificações residenciais, estabelecimentos comerciais, hotelarias, igrejas, instituições de ensino, sedes de parques ecológicos e ambientais, estruturas de locais de eventos, coberturas especiais, estruturas de arquibancadas, parques turísticos e com brinquedos infantis, terminal de aeroporto, torres de observação, estruturas provisórias de cimbramentos para formas de estruturas de concreto, defensas de rodovias, barreiras acústicas, entre outros, construídos no Brasil e no exterior. Estes sistemas estruturais proporcionam a economia e favorecem o meio ambiente de forma sustentável, e principalmente promovendo o ciclo de geração das novas florestas, imprescindíveis para o sequestro de carbono. / The object of this work is to propose the draft for a handbook with recommendations for the design and construction of structures using treated roundwood originating from forest farming in Brazil. Roundwood structures were classified and characterized visually and mechanically. Guidelines were presented for the desing of bridges and barns with structural and building systems using roundwood timber harvested from reforestation projects. Results will be compiled into a manual of design and construction of timber structures using roundwood. The study also had the purpose to publicize through the cataloging in 124 fact sheets of the alternatives for wooden structures in civil construction work with roundwood, such as pole for foundation piling, walkways, bridges, kiosks, farm barns, residential housing, business stores, hotels, churches, schools, ecological and environmental parks, structures for public shows and events, special coverage structures, bleachers, tourist parks and playgrounds, airport terminal, observation towers, forming wood for concrete structures, highway barriers, noise barriers, among others, to be built in Brazil and abroad. These systems provide financial savings and are good for the environment in a sustainable manner, especially by promoting the cycle of generation of new forests that crucial for carbon sequestration.
23

Contribuição ao estudo da estabilidade de edifícios de andares múltiplos em aço / Contribution to the study of stability of steel multi-storey buildings

Rafael Eclache Moreira de Camargo 20 August 2012 (has links)
Este trabalho apresenta uma análise comparativa de diferentes sistemas estruturais para um edifício de 20 pavimentos. Cada um dos modelos foi dimensionado através dos princípios do método da análise direta, presente na ABNT NBR 8800:2008. O método da amplificação dos esforços solicitantes (MAES) foi usado para se obter de forma simplificada os esforços atuantes nos elementos do edifício considerando os efeitos locais e globais de segunda ordem. A incidência do vento foi simulada de duas formas diferentes. Na primeira, chamada de uniforme, o vento foi aplicado sem excentricidade, gerando apenas o efeito de tombamento nas estruturas. Na segunda hipótese, considerou-se uma excentricidade devida aos efeitos de vizinhança, prescrita pela ABNT NBR 6123:1988, responsável por ocasionar o tombamento e a torção dos edifícios. Todas as análises numéricas foram repetidas fazendo o uso de outro método simplificado de segunda ordem, conhecido como P-Delta. Por meio dos resultados obtidos, constatou-se que a possibilidade de se reduzir a sobrecarga para o dimensionamento de pilares proporciona uma economia de material, mas, por outro lado, tem como consequência o aumento do tempo de análise, pois exige a utilização de diferentes combinações de cálculo para o dimensionamento de vigas e pilares. A estratégia utilizada para simular os efeitos de vizinhança mostrou-se satisfatória, pois permitiu introduzir de maneira fácil e prática a torção ocasionada pela incidência excêntrica do vento. Observou-se também que esses efeitos ocasionaram o aumento dos momentos fletores e dos deslocamentos das estruturas analisadas. Em relação à avaliação dos efeitos de segunda ordem, comprovou-se que, para a classificação da deslocabilidade, a combinação de cálculo crítica é aquela que possui o maior carregamento gravitacional. Entretanto, para o dimensionamento dos elementos, foi constatado que outras hipóteses de cálculo, principalmente aquelas em que o vento é a ação variável principal, podem ser determinantes. Por fim, foi observado que os resultados obtidos pelo método P-Delta ficaram bastante semelhantes àqueles calculados pelo MAES, com desvios desprezíveis. O MAES, por sua vez, mostrou-se bastante trabalhoso, pois exige a modelagem de diferentes tipos de estruturas para a determinação dos esforços. / This work presents a comparative analysis of different structural systems for a 20-storey building. Each model has been designed using the principles of the direct analysis method (DAM), present in the ABNT NBR 8800:2008. The first-order amplification method (FOAM) was used to obtain, in a simplified manner, the forces acting on the building elements, including local and global second-order effects. The incidence of the wind was simulated in two different ways. In the first case, named uniform, the wind was applied without eccentricity, generating only structure overturning. In the second case, it was considered an eccentricity due to vicinity effects, prescribed by the ABNT NBR 6123:1988, responsible for causing twisting and building overturning. All numerical analysis were carried out a simplified second-order method known as P-Delta. From the results obtained it was found that the reduction of live loads in the design of columns provides material economy, but on the other hand, increases analysis time, since it requires different combinations for beams and columns. The strategy used to simulate the vicinity effects was satisfactory, because it allowed, in an easy and practical way, the consideration of the torsion produced by the wind eccentric impact. It was also observed that these effects increased the bending moments and the displacements of the structures. About the second-order effects, it was shown that, for sway or non-sway classification, the critical combination is one with greatest gravitational loading. However, for the design of the elements, it was observed that other loading conditions can be critical, especially those in which the wind is the main live load. Finally, the results obtained by the P-Delta method were very similar to those calculated by the first-order amplification method. The FOAM was, in turn, very laborious, because it requires the modeling of different types of structures for the determination of the forces.
24

Special Issue: 2015 ASME Conference on Smart Materials, Adaptive Structures and Intelligent Systems (SMASIS), Symposium on Modeling, Simulation and Control of Adaptive Systems

Kiefer, Björn, Marschner, Uwe, Mahoodi, S. Nima 25 October 2019 (has links)
The 2015 ASME Conference on Smart Materials, Adaptive Structures and Intelligent Systems (SMASIS) was held from 21 to 23 September 2015, in Colorado Springs, Colorado. The scope of the conference covers intelligent, flexible, adaptive materials and systems that respond to changes in the environment to perform in the most profitable way. Scientific strides and technological maturity in the field are linked to the interdisciplinary efforts at universities, government and industry. SMASIS aims at assembling world experts across engineering and scientific disciplines such as mechanical, aerospace, electrical, materials, and civil engineering, as well as biology, physics and chemistry, to discuss the latest findings and trends in this fruitful area of research.

Page generated in 0.0435 seconds