• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • Tagged with
  • 23
  • 23
  • 23
  • 18
  • 16
  • 16
  • 13
  • 13
  • 13
  • 13
  • 12
  • 10
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Remoção de matéria orgânica residual e nitrogênio de efluente de reator UASB de indústria de insumos para ração animal em reator de leito estruturado / Residual organic matter and nitrogen removal from UASB reactor effluent of raw materials industry for animal food in a structured-bed reactor

Almeida, Ricardo Gabriel Bandeira de 07 October 2016 (has links)
O objetivo do presente trabalho foi avaliar o desempenho de um reator de leito fixo e fluxo ascendente (RLFFA) em escala de bancada submetido à baixa aeração e recirculação. O reator foi utilizado como um sistema de pós-tratamento do efluente de indústria de fabricação de ração animal (INCOFAP) a partir de resíduos de abatedouro de aves, caracterizado por elevada carga de nitrogênio amoniacal. Para tanto, o RLFFA foi avaliado quanto à remoção da fração remanescente de matéria orgânica e de nitrogênio do efluente do reator UASB instalado na indústria. O RLFFA foi operado em condições mesofílicas (30°C) e tinha volume total de 11,5 L e volume útil de 6,1 L, com leito estruturado composto por 13 estruturas cilíndricas (3 cm de diâmetro) de espuma de poliuretano, dispostas verticalmente no interior do reator. O reator apresentou sistema de recirculação interna, com razão de recirculação igual a 3, suficiente para garantir a mistura completa. O sistema foi operado em três condições distintas, que foram denominadas de fases, todas com tempo de detenção hidráulica (TDH) de 24 horas e concentração de oxigênio dissolvido próxima a 1,0 mg.L-1. Nas fases 1 e 2, o RLFFA foi alimentado com 20% de efluente do UASB diluídos em água, e a alimentação da Fase 3 foi com 10% de efluente. As relações DQO/N para as Fases de 1 a 3 foram de, respectivamente, 0,28, 0,41 e 0,26. Na Fase 1, a alcalinidade foi mantida em concentração estequiométrica para a ocorrência da nitrificação total, enquanto nas fases 2 e 3 a alcalinidade foi adicionada em excesso. As melhores eficiências de remoção de N-total e DQO foram obtidas na Fase 1, com respectivamente, 48 ± 24% e 63 ± 20%, atingindo remoção máxima de N-total de 79% e 92% para DQO. As análises estatísticas demonstraram independência entre a remoção de DQO e a remoção de N-total, e com demanda de doador de elétrons para desnitrificação heterotrófica via nitrato superior à DQO removida, indicando a ocorrência de vias complementares. A desnitrificação via nitrito e a desnitrificação autotrófica foram observadas nos ensaios cinéticos de desnitrificação via nitrito e teste de atividade para desnitrificação autotrófica utilizando sulfeto como doador de elétrons. A modelagem para qualidade da água do rio Chibarro( local de lançamento do efluente da empresa INCOFAP) utilizando uma modificação do modelo de Streeter-Phelps, indicou que o cenário com a adoção do reator estudado no presente trabalho para tratamento do efluente da INCOFAP permitiu reduzir o impacto para a qualidade da água do rio Chibarro ao se comparar ao sistema atual de tratamento do efluente da empresa INCOFAP. Entretando, ainda faz-se necessária a elevação da eficiência de remoção de N-total no sistema, para atingir a concentração máxima de N-amoniacal permitida de 20 mg.L-1 para o efluente para compatibilização com a capacidade de autodepuração do rio Chibarro. / The objective of this study was to evaluate the performance of a bench scale up-flow fixedbed reactor (UFBR) subjected to low aeration and effluent recirculation.The reactor was used as a post-treatment system of effluent from animal food plant (INCOFAP) using poultry slaughterhouse wastes, characterized by high ammoniacal nitrogen load rate.Therefore, the UFBR was evaluated in respect to residual organic matter and nitrogen removal of industrys UASB reactor effluent. The UFBR was operated in mesophilic conditions (30°C) and it had a total volume of 11.5 L and a working volume of 6.1 L, with a structured bed composed by 13 polyurethane foam vertical cylindrical structures (3 cm of diameter) inside the reactor. The reactor was provided with internal recirculation system with recirculation ratio of 3, suficiente to guarantee a complete mixture. The system was operated in three different phases, with hydraulic retention time (HRT)of 24 hours and dissolved oxygen concentration close to 1.0 mg.L-1.On Phases 1 and 2, the UFBR was fed with 20% of UASB effluent diluted in water,and the Phase 3 was fed with 10% of effluent. On phases 1 to 3 COD/N ratios were, respectively, 0.28, 0.41 and 0.26. The alkalinity on Phase 1 was maintained on stoichiometric concentration to total nitrification, while in phases 2 and 3 excess alkalinity was added. The best total nitrogen and COD removal efficiencies were obtained in Phase 1, with respectively, 48 ± 24% and 63 ± 20% , reaching maximum total nitrogen removal of 79% and 92% for COD. Statistical analysis demonstrated independency between COD and total nitrogen removal, and with higher electron donor demand for nitrate denitrification than COD removal, indicating the occurrence of complementary paths. The nitrite denitrification and autotrophic denitrification were noted in kinetics experiments and activity tests for autotrophic denitrification using sulfide as source of electron donors. The modeling for Chibarro river water quality (site of INCOFAPs effluent release) , using a modified Streeter-Phelps model, indicated the scenario with the adoption of the studied reactor on this work for INCOFAP's effluent treatment provided the reduction of the impact on Chibarros water quality in comparison with the current effluent treatment of INCOFAP. However, it is still necessary an increase on system denitrification efficiency to reach the maximum ammoniacal nitrogen concentration allowed of 20 mg.L-1 for the effluent to make compatible with de selfpurification of Chibarro river.
12

Remoção de matéria orgânica e nitrogênio de esgoto sanitário em reator de leito estruturado submetido à aeração intermitente e recirculação do efluente / Simultaneous carbon and nitrogen removal from sewage in a structured bed biofilm reactor subjected to intermittent aeration and effluent recirculation

Moura, Rafael Brito de 10 October 2014 (has links)
O objetivo deste trabalho foi o de avaliar o desempenho de um reator de leito estruturado submetido à aeração intermitente (LEAI) na remoção de matéria orgânica e nitrogênio de esgoto sanitário. O reator apresentava um volume total de 11,6 L, com uma porosidade do leito de 52%. O leito estruturado era composto de 13 estruturas cilíndricas (diâmetro igual a 3 cm) de espuma de poliuretano, dispostas verticalmente no interior do reator. A alimentação do reator era feita continuamente com esgoto sanitário, sendo este proveniente de um interceptor de esgoto que passava próximo ao laboratório onde o sistema foi montado. O reator era provido de sistema de recirculação interna, com razão de recirculação igual a 3, valor este adotado após a realização de ensaios hidrodinâmicos. Foram testadas 4 condições operacionais diferentes, variando-se o tempo de detenção hidráulica (TDH) e os períodos de aeração e não aeração. Para cada condição operacional, foram feitos os seguintes estudos: avaliação da eficiência de remoção de matéria orgânica e nitrogênio, determinação da atividade nitrificante e desnitrificante, determinação do número mais provável (NMP) da comunidade nitrificante e desnitrificante, perfis temporais e análise da comunidade microbiana. O sistema apresentou elevada remoção de N-total, com valores médios de 80% para valores de TDH de 12 e 10 horas, sob 2 horas de aeração e 1 hora sem aeração. Com a diminuição do TDH para 8 horas, houve queda na eficiência do sistema para 70% (mantendo-se os períodos de aeração de 2 horas e não aeração de 1 hora). Alterando-se o período de aeração para 3 horas, mantendo-se em 1 hora o período sem aeração, o reator apresentou eficiência média de remoção de N-total de 79% com o TDH de 8 horas. A remoção de DQO foi elevada em todas as fases, com valores médios em torno de 90%. Os resultados da atividade nitrificante e desnitrificante foram condizentes com valores encontrados na literatura para sistemas que operam com remoção simultânea de matéria orgânica e nitrogênio. Os perfis temporais mostraram que não houve variação nas formas de nitrogênio (N-NH4+, N-NO2- e N-NO3-) no efluente, apesar da operação sob a aeração intermitente devido ao grau de mistura imposto pela recirculação interna. A concentração de sólidos no efluente foi relativamente baixa quando comparada à concentração de efluentes de reatores de biomassa suspensa, com valor máximo de SSV igual a 108mgSSV.L-1. A presença do Metazoário Aelosomas sp no efluente do reator indica um possível consumo do lodo excedente no reator por esses microrganismos. As análises microbiológicas mostraram uma elevada abundância relativa de gêneros aeróbios facultativos, capazes de utilizar N-NO3- e N-NO2- como receptor de elétrons na ausência de oxigênio. Também se verificou a presença do gênero Comamonas sp em elevada abundância relativa. Esse gênero apresenta microrganismos capazes de realizar a nitrificação heterotrófica e a desnitrificação aeróbia. No entanto, os ensaios realizados não permitem inferir sobre a ocorrência desses processos. Desse modo, os processos convencionais de nitrificação e desnitrificação, tanto pela estratificação do biofilme devido à formação de gradiente de concentração de oxigênio dissolvido, quanto devido à aeração intermitente, certamente tiveram papel preponderante na remoção de nitrogênio. Os resultados obtidos permitem considerar o reator LEAI como uma alternativa tecnicamente viável para a remoção simultânea de matéria orgânica e nitrogênio de esgotos sanitários. / This study aimed at evaluating the organic matter and nitrogen removal from sewage in a structured bed reactor subjected to intermittent aeration. The reactor had a total volume of 11.6 L and bed porosity of 52%. Thirteen polyurethane foam cylinders of 3 cm diameter and 60 cm height were fixed vertically inside the reactor using PVC rods. The reactor was continuously fed with sewage collected from a sanitary sewer passing near the laboratory where the system was assembled. The reactor was provided with internal recirculation system with a recirculation ratio at 3, a value adopted after conducting hydrodynamic tests. Four different operating conditions were tested, varying the hydraulic retention time (HRT) and aeration and non-aeration periods. Nitrogen and organic matter removal efficiencies, nitrifying and denitrifying activities, and the most probable number (MPN) of nitrifying and denitrifying communities were evaluated for each operational condition. The reactor presented a Total-N removal efficiency of 80%, at HRT of 12 hours and 10 hours and aerated and non-aerated periods of 2 hours and 1 hour, respectively. With decreasing the HRT to 8 hours, the Total-N removal efficiency decreased to 70% for the same aeration and non-aeration periods. After increasing the aerated period to 3 hours and keeping the non-aerated periods of 1 hour and HRT of 8 hours, the system attained the Total-N removal efficiency of 79%. COD removal efficiencies were about 90% in all operational condition. Nitrifying and denitrifying activities were similar to those found in the literature for systems presenting simultaneous nitrification and denitrification, and carbon removal. No variation in nitrogen forms (NO3--N, NO2--N and NH4+-N) was observed during a cycle of intermittent aeration. The solids concentration in effluent was relatively low compared to the concentration of suspended-growth biomass reactors, with a maximum value of VSS of 108 mgVSS.L-1. The presence of the metazoan Aelosomas sp in the effluent in all operational conditions indicated a possible use of the excess sludge in the reactor by these microorganisms. Microbiological analysis showed a high relative abundance of aerobic/facultative microorganisms, capable to use NO3--N and NO2--N as electron acceptor in the absence of oxygen. It was also verified the presence of the genus Comamonas sp with high relative abundance. This genus presents microorganisms able to perform heterotrophic nitrification and aerobic denitrification. However, the assays do not allow us to infer the occurrence of these processes. Thus, the conventional processes of nitrification and denitrification certainly played a preponderant role in nitrogen removal both by the stratification of the biofilm due to the formation of a concentration gradient of dissolved oxygen, as due to the intermittent aeration. The results allow considering the reactor as a viable technological alternative for the simultaneous removal of organic matter and nitrogen of sewage.
13

REATOR DE LEITO ESTRUTURADO COM AERAÇÃO INTERMITENTE PARA TRATAMENTO COMBINADO DE ESGOTO SANITÁRIO E PÓS TRATAMENTO DE EFLUENTE DE RALF

Oliveira, João Guilherme Baggio de 21 June 2016 (has links)
Made available in DSpace on 2017-07-21T18:53:07Z (GMT). No. of bitstreams: 1 Joao Guilherme Baggio de Oliveira.pdf: 2058376 bytes, checksum: 82bb5fa9502e9c114bd0570d5ed85d62 (MD5) Previous issue date: 2016-06-21 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The dumping of untreated effluents into water bodies can cause serious damage to the environment. Eutrophication, a phenomenon caused by the release of nutrients such as nitrogen and phosphorus, is one of those damages. Their occurrence promotes excessive growth of algae, decreased dissolved oxygen concentration. The conventional nitrogen removal processes employ two stages physically separated to nitrification and denitrification, which increases construction costs and operation of the process. Research has shown that some reactors models are efficient for simultaneous removal of chemical oxygen demand (COD) and total nitrogen (NT). In this sense, the objective of this study was to evaluate a bed reactor structured with intermittent aeration in the removal of COD and NT sewage untreated combined with effluent RALF. Worked with hydraulic retention time (HRT) fixed in 12 hours and recirculation flow (Qr) of the effluent 3, 2 and 1 to the input flow. Worked up with three times aeration: 33%, 50% and 100% of the time. The affluent used was composed of a fraction of 50% of sewage untreated and 50% of effluent from a reactor Anaerobic Fluidized Bed (RALF). The results indicated that there was no statistical difference between the COD removal rates, regardless of the value of Qr and the reactor aeration time. The COD value obtained for the reactor effluent ranged between 27 and 68 mg.L-1. Values of Total Kjeldahl Nitrogen (TKN) affluent ranged between 40 and 52 mg L-1. Obtained removal rate NT of 50 to 78%, effluent generated treated with N-NH4+ content between 0.7 and 7.1 mg.L-1. We observed the occurrence of nitrification and denitrification Simultaneous (NDS) as oxidized forms were detected (nitrite and nitrate) and reduced (N -NH4) nitrogen at all stages studied. It was concluded that the bed reactor structured with intermittent aeration is effective in joint COD removal and sewage nitrogen / O despejo de efluentes não tratados em corpos d’água pode causar sérios danos ao meio ambiente. A eutrofização, fenômeno causado pelo lançamento de nutrientes como o nitrogênio e fósforo, é um desses danos. A sua ocorrência promove o crescimento exagerado de algas, diminuição da concentração de oxigênio dissolvido. Os processos convencionais de remoção de nitrogênio utilizam duas etapas fisicamente separadas para a nitrificação e desnitrificação, o que aumenta custos com construção e operação do processo. Pesquisas têm mostrado que alguns modelos de reatores são eficientes para remoção concomitante de Demanda Química de Oxigênio (DQO) e nitrogênio total (NT). Neste sentido, o objetivo deste trabalho foi avaliar um reator de leito estruturado com aeração intermitente na remoção de DQO e NT de esgoto sanitário não tratado combinado com efluente de RALF. Trabalhou-se com Tempo de Detenção Hidráulica (TDH) fixo em 12 horas evazão de recirculação (Qr) do efluente de 3, 2 e 1 vez a vazão de entrada. Trabalhou-se com três tempos de aeração: 33%, 50% e 100% do tempo.O afluente utilizado foi composto por uma fração de 50% de esgoto sanitário não tratado e 50% de efluente de um Reator Anaeróbio de Leito Fluidizado (RALF). Os resultados indicaram que não houve diferença estatística entre as taxas de remoção de DQO, independentemente de Qr e tempo de aeração do reator. Os valores de DQO obtidos para o efluente do reator variaram entre 27 e 68 mg.L-1. Os valores de Nitrogênio Total Kjeldahl (NTK) afluente variaram entre 40 e 52 mg.L-1. Obteve-se taxas de remoção de NT de 50 a 78%, geraram efluente tratado com teor de N-NH4+ entre 0,7 e 7,1 mg.L-1. Observou-se a ocorrência de Nitrificação e Desnitrificação Simultâneas (NDS), pois foram detectadas formas oxidadas (nitrito e nitrato) e reduzidas (N-NH4+) de nitrogênio em todas as fases estudadas. Foi possível concluir que o reator de leito estruturado com aeração intermitente é eficiente na remoção conjunta de DQO e nitrogênio de esgoto doméstico.
14

REATOR DE LEITO EMPACOTADO EM ESCALA PILOTO PARA REMOÇÃO DE MATÉRIA ORGÂNICA E NITROGENADA DE ESGOTO SANITÁRIO

Polak, Rafael 23 July 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-12-11T11:55:47Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Rafael Polak.pdf: 5152873 bytes, checksum: 5f30b3bcb29a2f08c434a1b4def58c5a (MD5) / Made available in DSpace on 2018-12-11T11:55:47Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Rafael Polak.pdf: 5152873 bytes, checksum: 5f30b3bcb29a2f08c434a1b4def58c5a (MD5) Previous issue date: 2018-07-23 / Essa pesquisa teve por objetivo principal avaliar o desempenho de um reator em escala piloto de leito empacotado e fluxo contínuo sob diferentes condições operacionais de aeração, na remoção biológica de matéria carbonácea e nitrogenada, de efluente sanitário. O reator possuía um volume total de 5,65 m³ e volume útil de 4,75 m³, devido ao volume ocupado pelo material suporte. O meio suporte utilizado para fixação de microrganismos foi o dispositivo denominado Biobob®, que consiste em uma matriz de espuma de poliuretano envolta por uma estrutura de polipropileno, com geometria cilíndrica de 45 mm de diâmetro e 60 mm de altura. O reator foi operado com um Tempo de Detenção Hidráulica (TDH) de 12 horas, razão de recirculação de 2 vezes vazão de alimentação e foi alimentado continuamente por afluente composto por mistura de esgoto sanitário não tratado e efluente de Reator Anaeróbio de Leito Fluidizado (RALF) na proporção de 1:1 (v:v). Foram explorados três ciclos de operação de 180 minutos: (10) aerando continuamente por 180 minutos, (2) aerando 60 minutos e não aerando 120 minutos, e (3) aerando 120 minutos e não aerando 60 minutos. Os resultados mostraram não haver diferença estatística nas eficiências de reduções de Demanda Química Oxigênio (DQO) entre as três condições estudadas, com eficiências médias de 76,34%, 75,32% e 79,80%, respectivamente, indicando que o tempo de aeração não influenciou na eficiência de redução. A DQO efluente do reator variou entre 31 mg.L-1 e 206 mg.L-1. A eficiência de nitrificação se mostrou fator limitante na remoção de NT. As condições (1) e (3) com maiores taxas de nitrificação, 75% e 70% respectivamente, obtiveram as melhores eficiências de remoção de NT, com taxas de 65% em ambas. A relação DQO/NTK durante as 3 etapas da pesquisa foi próxima a 9,59. A condição (3) apresentou diferença estatística significativa na remoção de NT devido a maior disponibilidade de doadores de elétrons, com relação DQO/NTK de 11,2. A desnitrificação apresentou médias de remoções de 87%, 89% e 94%, nas condições 1, 2 e 3, respectivamente. Pelos resultados obtidos, pode-se concluir que o reator piloto de leito empacotado e aeração intermitente foi eficiente na remoção simultânea de matéria orgânica e nitrogenada, podendo ser considerado uma alternativa interessante a ser utilizada no tratamento combinado de efluente de UASB e esgoto bruto. / The main objective of this research was to evaluate the performance of a pilot scale reactor of packed bed and continuous flow, on different aeration operating conditions, in the biological removal of carbonaceous and nitrogenous matter from sanitary effluent. The reactor has a total volume of 5.65 m³, and a useful volume of 4.75 m³ due to the volume occupied by the structured bed. The medium used to fix microorganisms was the device called Biobob®, which consists of a polyurethane foam matrix enveloped by a polypropylene structure, with a cylindrical geometry of 45 mm in diameter and 60 mm in height. The reactor was operated with a 12 hour Hydraulic Retention Time (HRT), recirculation rate of 2 times feed rate and was continuously fed by a mixture of untreated sewage and effluent from an Upflow Anaerobic Sludge Blanket (UASB) in the proportion of 1:1 (v:v). Three 180-minute cycles of operation were performed: (1) continuous aeration for 180 minutes, (2) aeration 60 minutes and no aeration for 120 minutes and (3) aeration for 120 minutes and no aeration for 60 minutes. The results showed that there was no statistical difference in the efficiency of Chemical Oxygen Demand (COD) reductions between the three conditions studied, with mean efficiencies of 76.34%, 75.32% and 79.80%, respectively, indicating that the aeration did not influence the reduction efficiency. The COD concentrations effluent from the reactor varied between 31 mg.L-1 and 206 mg.L-1. The efficiency of nitrification was shown to be a limiting factor in NT removal. The conditions (1) and (3) with higher nitrification rates, 75% and 70%, respectively, obtained the best NT removal efficiencies, with rates of 65% in both. The COD / NTK ratio presented a high average during the 3 stages of the research, with an observed value of 9.59. Denitrification showed mean removals of 87% (1), 89% (2) and 94% (3). Condition (3) presented a statistically significant difference with the others due to the greater availability of electron donors, with a COD/NTK ratio of 11.2. From the results, we can conclude that the packed bed reactor and intermittent aeration is efficient in the simultaneous removal of organic matter and nitrogen and is an interesting alternative to be used in the treatment and post treatment of anaerobic reactors.
15

Influência da relação carbono/nitrogênio e da fonte de carbono no processo de nitrificação desnitrificação simultânea em reator de leito estruturado / Influence of COD/N ratio and carbon source on the simultaneous nitrification and denitrification in a structured-bed reactor

Santos, Carla Eloísa Diniz dos 25 March 2014 (has links)
Este trabalho buscou avaliar a influência da relação C/N e da fonte de carbono no processo de nitrificação e desnitrificação simultâneas em reator de fluxo contínuo e leito fixo estruturado. Foi utilizado um reator vertical de acrílico, com volume total de 11,0 L e volume útil de 5,5 L, com hastes cilíndricas verticais de espuma de poliuretano como suporte para a biomassa. O sistema foi operado com TDH de 11,2±0,6 horas, aeração intermitente (2 horas com aeração e 1 hora sem aeração) e razão de recirculação de efluente igual a 5. A carga carbonácea afluente foi mantida constante (1,07 kg DQO.m-3.dia-1), ao longo de todo o período experimental, sendo as relações C/N testadas (9,7±1; 7,6±1; 2,9±1 e 2,9±0,4) obtidas a partir da variação na carga nitrogenada aplicada. Duas fontes orgânicas foram avaliadas: sacarose e peptona de carne. A eficiência média de remoção de DQO manteve-se acima de 90%. A eficiência máxima de remoção de N-total (84,6±10,1%) foi obtida para relação C/N de 2,9±1, com concentrações efluentes médias de NTK e N-NH4 de 5,9 e 4,3 mg.L-1, respectivamente. A análise estatística da eficiência de remoção de N-total confirmou que a fonte de carbono não exerceu influência sobre os processos de remoção. A obtenção de eficiências de desnitrificação superiores às calculadas estequiometricamente, em função da fonte de carbono, indicou a ocorrência de possíveis vias complementares para remoção de nitrogênio, como o processo anammox. As velocidades de nitrificação e desnitrificação obtidas nos ensaios cinéticos foram similares para as duas fontes de carbono e para as relações C/N estudadas e da mesma ordem de grandeza das apresentadas na literatura, reforçando a ideia de que a configuração de reator utilizada, aliada às adequadas condições operacionais, permitiu a remoção concomitante de matéria carbonácea e nitrogenada. / This study aimed to evaluate the influence of COD/N ratio and organic source on the simultaneous nitrification and denitrification (SND) in an up-flow structured-bed reactor. The reactor was made of acrylic with a total volume of 11 L and a working volume of 5.5 L and filled with cylinders of polyurethane foam as support for biomass growth. The system was continuously operated with an HRT of 11.2±0.6 h, intermittent aeration (2h with aeration and 1h without aerationd) and a liquid recycle ratio equal to 5. The organic load rate was constant (1.07 kg COD.m-3d-1) during the entire experiment. The COD/N ratios (9.7±1; 7.6±1; 2.9±1 and 2.9±0,4) were obtained from the variation of nitrogen load rate. Two organic sources were evaluated: sucrose and meat peptone. The average COD removal efficiency was above 90%. The maximum total nitrogen removal efficiency was 84.6±10.1%, with average TKN and NH4+-N effluent concentrations of 5.9 and 4.3 mg.L-1, respectively. Statistical analysis of total nitrogen removal efficiency confirmed that the carbon source did not influence over the removal processes. The denitrification efficiencies higher than the stoichiometrically calculated in function of the carbon source, indicated the occurrence of possible paths for nitrogen removal of nitrogen as anammox process. The nitrification and denitrification rates obtained in kinetic experiments were similar for the two sources of carbon and all C/N ratio studied at the same order of magnitude in relation to those reported in the literature, enhancing that the reactor configuration tested combined with the proper operational conditions allowed the organic matter and nitrogen removal simultaneously.
16

Remoção de matéria orgânica e nitrogênio de esgoto sanitário em reator de leito estruturado submetido à aeração intermitente e recirculação do efluente / Simultaneous carbon and nitrogen removal from sewage in a structured bed biofilm reactor subjected to intermittent aeration and effluent recirculation

Rafael Brito de Moura 10 October 2014 (has links)
O objetivo deste trabalho foi o de avaliar o desempenho de um reator de leito estruturado submetido à aeração intermitente (LEAI) na remoção de matéria orgânica e nitrogênio de esgoto sanitário. O reator apresentava um volume total de 11,6 L, com uma porosidade do leito de 52%. O leito estruturado era composto de 13 estruturas cilíndricas (diâmetro igual a 3 cm) de espuma de poliuretano, dispostas verticalmente no interior do reator. A alimentação do reator era feita continuamente com esgoto sanitário, sendo este proveniente de um interceptor de esgoto que passava próximo ao laboratório onde o sistema foi montado. O reator era provido de sistema de recirculação interna, com razão de recirculação igual a 3, valor este adotado após a realização de ensaios hidrodinâmicos. Foram testadas 4 condições operacionais diferentes, variando-se o tempo de detenção hidráulica (TDH) e os períodos de aeração e não aeração. Para cada condição operacional, foram feitos os seguintes estudos: avaliação da eficiência de remoção de matéria orgânica e nitrogênio, determinação da atividade nitrificante e desnitrificante, determinação do número mais provável (NMP) da comunidade nitrificante e desnitrificante, perfis temporais e análise da comunidade microbiana. O sistema apresentou elevada remoção de N-total, com valores médios de 80% para valores de TDH de 12 e 10 horas, sob 2 horas de aeração e 1 hora sem aeração. Com a diminuição do TDH para 8 horas, houve queda na eficiência do sistema para 70% (mantendo-se os períodos de aeração de 2 horas e não aeração de 1 hora). Alterando-se o período de aeração para 3 horas, mantendo-se em 1 hora o período sem aeração, o reator apresentou eficiência média de remoção de N-total de 79% com o TDH de 8 horas. A remoção de DQO foi elevada em todas as fases, com valores médios em torno de 90%. Os resultados da atividade nitrificante e desnitrificante foram condizentes com valores encontrados na literatura para sistemas que operam com remoção simultânea de matéria orgânica e nitrogênio. Os perfis temporais mostraram que não houve variação nas formas de nitrogênio (N-NH4+, N-NO2- e N-NO3-) no efluente, apesar da operação sob a aeração intermitente devido ao grau de mistura imposto pela recirculação interna. A concentração de sólidos no efluente foi relativamente baixa quando comparada à concentração de efluentes de reatores de biomassa suspensa, com valor máximo de SSV igual a 108mgSSV.L-1. A presença do Metazoário Aelosomas sp no efluente do reator indica um possível consumo do lodo excedente no reator por esses microrganismos. As análises microbiológicas mostraram uma elevada abundância relativa de gêneros aeróbios facultativos, capazes de utilizar N-NO3- e N-NO2- como receptor de elétrons na ausência de oxigênio. Também se verificou a presença do gênero Comamonas sp em elevada abundância relativa. Esse gênero apresenta microrganismos capazes de realizar a nitrificação heterotrófica e a desnitrificação aeróbia. No entanto, os ensaios realizados não permitem inferir sobre a ocorrência desses processos. Desse modo, os processos convencionais de nitrificação e desnitrificação, tanto pela estratificação do biofilme devido à formação de gradiente de concentração de oxigênio dissolvido, quanto devido à aeração intermitente, certamente tiveram papel preponderante na remoção de nitrogênio. Os resultados obtidos permitem considerar o reator LEAI como uma alternativa tecnicamente viável para a remoção simultânea de matéria orgânica e nitrogênio de esgotos sanitários. / This study aimed at evaluating the organic matter and nitrogen removal from sewage in a structured bed reactor subjected to intermittent aeration. The reactor had a total volume of 11.6 L and bed porosity of 52%. Thirteen polyurethane foam cylinders of 3 cm diameter and 60 cm height were fixed vertically inside the reactor using PVC rods. The reactor was continuously fed with sewage collected from a sanitary sewer passing near the laboratory where the system was assembled. The reactor was provided with internal recirculation system with a recirculation ratio at 3, a value adopted after conducting hydrodynamic tests. Four different operating conditions were tested, varying the hydraulic retention time (HRT) and aeration and non-aeration periods. Nitrogen and organic matter removal efficiencies, nitrifying and denitrifying activities, and the most probable number (MPN) of nitrifying and denitrifying communities were evaluated for each operational condition. The reactor presented a Total-N removal efficiency of 80%, at HRT of 12 hours and 10 hours and aerated and non-aerated periods of 2 hours and 1 hour, respectively. With decreasing the HRT to 8 hours, the Total-N removal efficiency decreased to 70% for the same aeration and non-aeration periods. After increasing the aerated period to 3 hours and keeping the non-aerated periods of 1 hour and HRT of 8 hours, the system attained the Total-N removal efficiency of 79%. COD removal efficiencies were about 90% in all operational condition. Nitrifying and denitrifying activities were similar to those found in the literature for systems presenting simultaneous nitrification and denitrification, and carbon removal. No variation in nitrogen forms (NO3--N, NO2--N and NH4+-N) was observed during a cycle of intermittent aeration. The solids concentration in effluent was relatively low compared to the concentration of suspended-growth biomass reactors, with a maximum value of VSS of 108 mgVSS.L-1. The presence of the metazoan Aelosomas sp in the effluent in all operational conditions indicated a possible use of the excess sludge in the reactor by these microorganisms. Microbiological analysis showed a high relative abundance of aerobic/facultative microorganisms, capable to use NO3--N and NO2--N as electron acceptor in the absence of oxygen. It was also verified the presence of the genus Comamonas sp with high relative abundance. This genus presents microorganisms able to perform heterotrophic nitrification and aerobic denitrification. However, the assays do not allow us to infer the occurrence of these processes. Thus, the conventional processes of nitrification and denitrification certainly played a preponderant role in nitrogen removal both by the stratification of the biofilm due to the formation of a concentration gradient of dissolved oxygen, as due to the intermittent aeration. The results allow considering the reactor as a viable technological alternative for the simultaneous removal of organic matter and nitrogen of sewage.
17

Remoção de \'CD POT.2+\' e \'CU POT.2+\' de águas residuárias utilizando biorreator anaeróbio contínuo de leito fixo ordenado / Wastewater \'CD POT.2+\' and \'CU POT.2+\' removal using a continuous Anaerobic Bioreactor with Fixed-Structured Bed

Mockaitis, Gustavo 21 March 2011 (has links)
O presente trabalho apresenta o biorreator anaeróbio contínuo de leito fixo ordenado como alternativa ao tratamento de efluentes contendo os íons \'CU POT.2+\' e \'CD POT.2+\', sendo que cada metal foi estudado isoladamente. O biorreator operou sempre com um tempo de detenção hidráulica de 12 à 15 horas, com uma água residuária sintética simulando o esgoto sanitário, na concentração de 500 mg \'0 IND.2\'/L (em termos de DQO), a uma temperatura de 30°C. Durante a fase na qual o biorreator operou com água residuária em condições metanogênicas o biorreator foi alimentado, em condições distintas, com concentrações crescentes de \'CU POT.2+\' e \'CD POT.2+\'. O acúmulo dos metais na matriz de imobilização levou ao bioreator apresentar instabilidade na operação, sendo determinadas as concentrações críticas para o \'CU POT.2+\' (50,8 mg \'CU POT.2+\'/L) e para o \'CD POT.2+\' (29,8 mg \'CD POT.2+\'/L). Durante a operação nas condições metanogênicas foi observado o efeito tóxico pela diminuição na eficiência de remoção de matéria orgânica, mas sem perder a estabilidade operacional até que as concentrações críticas foram atingidas. A partir dos valores das concentrações críticas, o biorreator foi operado em condições sulfetogênicas em duas relações DQO/[\'SO IND.4\'POT.2-\'] distintas (0,68 e 1,99 para o uma concentração média de 36 mg \'CU POT.2+\'/L; e 0,69 e 8,02 para uma concentração média de 27 mg \'CD POT.2+\'/L). Nas operações em condições sulfetogênicas, o biorreator operou de maneira estável, no entanto, não foi capaz de remover todo o metal alimentado. / This work presents the anaerobic continuous bioreactor with fixed-structured bed as a viable configuration of treatment of wastewater containing \'CU POT.2+\' and \'CD POT.2+\' ions. Each metallic ion were studied separately. The bioreactor was operated with 12 to 15 hours of hydraulic retention time, with a synthetic wastewater simulating domestic sewage (500 mg \'0 IND.2\'/L, in COD terms), at 30°C. In methanogenic conditions, the bioreactor was fed with crescent amount of \'CU POT.2+\' and \'CD POT.2+\'. The metal accumulation in the irnrnobilization matrix caused instability on bioreactor when achieving the critical concentrations for \'CU POT.2+\' (50,8 mg \'CU POT.2+\'/L) and for \'CD POT.2+\' (29,8 mg \'CD POT.2+\'/L). Also it was observed that this crescent metal concentration affected the efficiency of bioreactor in removing organic matter, although without operational instability until the system reach these critical metal concentrations. The bioreactor was operated in sulfidogenic conditions fed with a wastewater containing \'CU POT.2+\' and \'CD POT.2+\' at critical concentrations considering two different COD/[\'SO IND.4\'POT.2-\'] (0,68 and 1,99 for a mean influent \'CU POT.2+\' concentration of 36 mg \'CU POT.2+\'/L; and 0,69 and 8,02 para for a mean influent \'CD POT.2+\' concentration of 27 mg \'CD POT.2+\'/L). During the sulfidogenic conditions operations the bioreactor operated showing stability, however the system was not able to achieve the maximum efficiency in metal removal.
18

Remoção de \'CD POT.2+\' e \'CU POT.2+\' de águas residuárias utilizando biorreator anaeróbio contínuo de leito fixo ordenado / Wastewater \'CD POT.2+\' and \'CU POT.2+\' removal using a continuous Anaerobic Bioreactor with Fixed-Structured Bed

Gustavo Mockaitis 21 March 2011 (has links)
O presente trabalho apresenta o biorreator anaeróbio contínuo de leito fixo ordenado como alternativa ao tratamento de efluentes contendo os íons \'CU POT.2+\' e \'CD POT.2+\', sendo que cada metal foi estudado isoladamente. O biorreator operou sempre com um tempo de detenção hidráulica de 12 à 15 horas, com uma água residuária sintética simulando o esgoto sanitário, na concentração de 500 mg \'0 IND.2\'/L (em termos de DQO), a uma temperatura de 30°C. Durante a fase na qual o biorreator operou com água residuária em condições metanogênicas o biorreator foi alimentado, em condições distintas, com concentrações crescentes de \'CU POT.2+\' e \'CD POT.2+\'. O acúmulo dos metais na matriz de imobilização levou ao bioreator apresentar instabilidade na operação, sendo determinadas as concentrações críticas para o \'CU POT.2+\' (50,8 mg \'CU POT.2+\'/L) e para o \'CD POT.2+\' (29,8 mg \'CD POT.2+\'/L). Durante a operação nas condições metanogênicas foi observado o efeito tóxico pela diminuição na eficiência de remoção de matéria orgânica, mas sem perder a estabilidade operacional até que as concentrações críticas foram atingidas. A partir dos valores das concentrações críticas, o biorreator foi operado em condições sulfetogênicas em duas relações DQO/[\'SO IND.4\'POT.2-\'] distintas (0,68 e 1,99 para o uma concentração média de 36 mg \'CU POT.2+\'/L; e 0,69 e 8,02 para uma concentração média de 27 mg \'CD POT.2+\'/L). Nas operações em condições sulfetogênicas, o biorreator operou de maneira estável, no entanto, não foi capaz de remover todo o metal alimentado. / This work presents the anaerobic continuous bioreactor with fixed-structured bed as a viable configuration of treatment of wastewater containing \'CU POT.2+\' and \'CD POT.2+\' ions. Each metallic ion were studied separately. The bioreactor was operated with 12 to 15 hours of hydraulic retention time, with a synthetic wastewater simulating domestic sewage (500 mg \'0 IND.2\'/L, in COD terms), at 30°C. In methanogenic conditions, the bioreactor was fed with crescent amount of \'CU POT.2+\' and \'CD POT.2+\'. The metal accumulation in the irnrnobilization matrix caused instability on bioreactor when achieving the critical concentrations for \'CU POT.2+\' (50,8 mg \'CU POT.2+\'/L) and for \'CD POT.2+\' (29,8 mg \'CD POT.2+\'/L). Also it was observed that this crescent metal concentration affected the efficiency of bioreactor in removing organic matter, although without operational instability until the system reach these critical metal concentrations. The bioreactor was operated in sulfidogenic conditions fed with a wastewater containing \'CU POT.2+\' and \'CD POT.2+\' at critical concentrations considering two different COD/[\'SO IND.4\'POT.2-\'] (0,68 and 1,99 for a mean influent \'CU POT.2+\' concentration of 36 mg \'CU POT.2+\'/L; and 0,69 and 8,02 para for a mean influent \'CD POT.2+\' concentration of 27 mg \'CD POT.2+\'/L). During the sulfidogenic conditions operations the bioreactor operated showing stability, however the system was not able to achieve the maximum efficiency in metal removal.
19

Influência da relação carbono/nitrogênio e da fonte de carbono no processo de nitrificação desnitrificação simultânea em reator de leito estruturado / Influence of COD/N ratio and carbon source on the simultaneous nitrification and denitrification in a structured-bed reactor

Carla Eloísa Diniz dos Santos 25 March 2014 (has links)
Este trabalho buscou avaliar a influência da relação C/N e da fonte de carbono no processo de nitrificação e desnitrificação simultâneas em reator de fluxo contínuo e leito fixo estruturado. Foi utilizado um reator vertical de acrílico, com volume total de 11,0 L e volume útil de 5,5 L, com hastes cilíndricas verticais de espuma de poliuretano como suporte para a biomassa. O sistema foi operado com TDH de 11,2±0,6 horas, aeração intermitente (2 horas com aeração e 1 hora sem aeração) e razão de recirculação de efluente igual a 5. A carga carbonácea afluente foi mantida constante (1,07 kg DQO.m-3.dia-1), ao longo de todo o período experimental, sendo as relações C/N testadas (9,7±1; 7,6±1; 2,9±1 e 2,9±0,4) obtidas a partir da variação na carga nitrogenada aplicada. Duas fontes orgânicas foram avaliadas: sacarose e peptona de carne. A eficiência média de remoção de DQO manteve-se acima de 90%. A eficiência máxima de remoção de N-total (84,6±10,1%) foi obtida para relação C/N de 2,9±1, com concentrações efluentes médias de NTK e N-NH4 de 5,9 e 4,3 mg.L-1, respectivamente. A análise estatística da eficiência de remoção de N-total confirmou que a fonte de carbono não exerceu influência sobre os processos de remoção. A obtenção de eficiências de desnitrificação superiores às calculadas estequiometricamente, em função da fonte de carbono, indicou a ocorrência de possíveis vias complementares para remoção de nitrogênio, como o processo anammox. As velocidades de nitrificação e desnitrificação obtidas nos ensaios cinéticos foram similares para as duas fontes de carbono e para as relações C/N estudadas e da mesma ordem de grandeza das apresentadas na literatura, reforçando a ideia de que a configuração de reator utilizada, aliada às adequadas condições operacionais, permitiu a remoção concomitante de matéria carbonácea e nitrogenada. / This study aimed to evaluate the influence of COD/N ratio and organic source on the simultaneous nitrification and denitrification (SND) in an up-flow structured-bed reactor. The reactor was made of acrylic with a total volume of 11 L and a working volume of 5.5 L and filled with cylinders of polyurethane foam as support for biomass growth. The system was continuously operated with an HRT of 11.2±0.6 h, intermittent aeration (2h with aeration and 1h without aerationd) and a liquid recycle ratio equal to 5. The organic load rate was constant (1.07 kg COD.m-3d-1) during the entire experiment. The COD/N ratios (9.7±1; 7.6±1; 2.9±1 and 2.9±0,4) were obtained from the variation of nitrogen load rate. Two organic sources were evaluated: sucrose and meat peptone. The average COD removal efficiency was above 90%. The maximum total nitrogen removal efficiency was 84.6±10.1%, with average TKN and NH4+-N effluent concentrations of 5.9 and 4.3 mg.L-1, respectively. Statistical analysis of total nitrogen removal efficiency confirmed that the carbon source did not influence over the removal processes. The denitrification efficiencies higher than the stoichiometrically calculated in function of the carbon source, indicated the occurrence of possible paths for nitrogen removal of nitrogen as anammox process. The nitrification and denitrification rates obtained in kinetic experiments were similar for the two sources of carbon and all C/N ratio studied at the same order of magnitude in relation to those reported in the literature, enhancing that the reactor configuration tested combined with the proper operational conditions allowed the organic matter and nitrogen removal simultaneously.
20

Remoção de matéria orgânica residual e nitrogênio de efluente de reator UASB de indústria de insumos para ração animal em reator de leito estruturado / Residual organic matter and nitrogen removal from UASB reactor effluent of raw materials industry for animal food in a structured-bed reactor

Ricardo Gabriel Bandeira de Almeida 07 October 2016 (has links)
O objetivo do presente trabalho foi avaliar o desempenho de um reator de leito fixo e fluxo ascendente (RLFFA) em escala de bancada submetido à baixa aeração e recirculação. O reator foi utilizado como um sistema de pós-tratamento do efluente de indústria de fabricação de ração animal (INCOFAP) a partir de resíduos de abatedouro de aves, caracterizado por elevada carga de nitrogênio amoniacal. Para tanto, o RLFFA foi avaliado quanto à remoção da fração remanescente de matéria orgânica e de nitrogênio do efluente do reator UASB instalado na indústria. O RLFFA foi operado em condições mesofílicas (30°C) e tinha volume total de 11,5 L e volume útil de 6,1 L, com leito estruturado composto por 13 estruturas cilíndricas (3 cm de diâmetro) de espuma de poliuretano, dispostas verticalmente no interior do reator. O reator apresentou sistema de recirculação interna, com razão de recirculação igual a 3, suficiente para garantir a mistura completa. O sistema foi operado em três condições distintas, que foram denominadas de fases, todas com tempo de detenção hidráulica (TDH) de 24 horas e concentração de oxigênio dissolvido próxima a 1,0 mg.L-1. Nas fases 1 e 2, o RLFFA foi alimentado com 20% de efluente do UASB diluídos em água, e a alimentação da Fase 3 foi com 10% de efluente. As relações DQO/N para as Fases de 1 a 3 foram de, respectivamente, 0,28, 0,41 e 0,26. Na Fase 1, a alcalinidade foi mantida em concentração estequiométrica para a ocorrência da nitrificação total, enquanto nas fases 2 e 3 a alcalinidade foi adicionada em excesso. As melhores eficiências de remoção de N-total e DQO foram obtidas na Fase 1, com respectivamente, 48 ± 24% e 63 ± 20%, atingindo remoção máxima de N-total de 79% e 92% para DQO. As análises estatísticas demonstraram independência entre a remoção de DQO e a remoção de N-total, e com demanda de doador de elétrons para desnitrificação heterotrófica via nitrato superior à DQO removida, indicando a ocorrência de vias complementares. A desnitrificação via nitrito e a desnitrificação autotrófica foram observadas nos ensaios cinéticos de desnitrificação via nitrito e teste de atividade para desnitrificação autotrófica utilizando sulfeto como doador de elétrons. A modelagem para qualidade da água do rio Chibarro( local de lançamento do efluente da empresa INCOFAP) utilizando uma modificação do modelo de Streeter-Phelps, indicou que o cenário com a adoção do reator estudado no presente trabalho para tratamento do efluente da INCOFAP permitiu reduzir o impacto para a qualidade da água do rio Chibarro ao se comparar ao sistema atual de tratamento do efluente da empresa INCOFAP. Entretando, ainda faz-se necessária a elevação da eficiência de remoção de N-total no sistema, para atingir a concentração máxima de N-amoniacal permitida de 20 mg.L-1 para o efluente para compatibilização com a capacidade de autodepuração do rio Chibarro. / The objective of this study was to evaluate the performance of a bench scale up-flow fixedbed reactor (UFBR) subjected to low aeration and effluent recirculation.The reactor was used as a post-treatment system of effluent from animal food plant (INCOFAP) using poultry slaughterhouse wastes, characterized by high ammoniacal nitrogen load rate.Therefore, the UFBR was evaluated in respect to residual organic matter and nitrogen removal of industrys UASB reactor effluent. The UFBR was operated in mesophilic conditions (30°C) and it had a total volume of 11.5 L and a working volume of 6.1 L, with a structured bed composed by 13 polyurethane foam vertical cylindrical structures (3 cm of diameter) inside the reactor. The reactor was provided with internal recirculation system with recirculation ratio of 3, suficiente to guarantee a complete mixture. The system was operated in three different phases, with hydraulic retention time (HRT)of 24 hours and dissolved oxygen concentration close to 1.0 mg.L-1.On Phases 1 and 2, the UFBR was fed with 20% of UASB effluent diluted in water,and the Phase 3 was fed with 10% of effluent. On phases 1 to 3 COD/N ratios were, respectively, 0.28, 0.41 and 0.26. The alkalinity on Phase 1 was maintained on stoichiometric concentration to total nitrification, while in phases 2 and 3 excess alkalinity was added. The best total nitrogen and COD removal efficiencies were obtained in Phase 1, with respectively, 48 ± 24% and 63 ± 20% , reaching maximum total nitrogen removal of 79% and 92% for COD. Statistical analysis demonstrated independency between COD and total nitrogen removal, and with higher electron donor demand for nitrate denitrification than COD removal, indicating the occurrence of complementary paths. The nitrite denitrification and autotrophic denitrification were noted in kinetics experiments and activity tests for autotrophic denitrification using sulfide as source of electron donors. The modeling for Chibarro river water quality (site of INCOFAPs effluent release) , using a modified Streeter-Phelps model, indicated the scenario with the adoption of the studied reactor on this work for INCOFAP's effluent treatment provided the reduction of the impact on Chibarros water quality in comparison with the current effluent treatment of INCOFAP. However, it is still necessary an increase on system denitrification efficiency to reach the maximum ammoniacal nitrogen concentration allowed of 20 mg.L-1 for the effluent to make compatible with de selfpurification of Chibarro river.

Page generated in 0.0701 seconds