• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • Tagged with
  • 16
  • 16
  • 13
  • 9
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Esquema de auxílio ao diagnóstico de reabsorção óssea periodontal através de subtração digital de radiografias odontológicas / Aided diagnosis scheme for periodontal bone resorption through odontological digital subtraction radiography

Eveline Batista Rodrigues 09 August 2006 (has links)
A radiografia é uma das ferramentas primárias de auxílio ao diagnóstico e monitoração do tratamento das doenças periodontais. Porém, a análise subjetiva dessas radiografias feita pelo dentista só consegue identificar lesões quando o quadro clínico apresenta perda acima de 30% do conteúdo mineral do osso, levando um sério desafio ao exercício da odontologia. Em muitas situações clínicas, o dentista também precisa ser capaz de quantificar o tamanho de uma lesão para determinar a taxa de progressão ou cura da doença. A técnica de subtração digital de radiografias provê a detecção de mudanças ósseas sutis, de cerca de 5%, levando ao diagnóstico precoce da doença e aumentando assim o sucesso de seu tratamento. Desta forma, o esquema de auxílio ao diagnóstico de reabsorção óssea periodontal através de subtração digital de radiografias odontológicas proposto no presente trabalho emprega a técnica de subtração digital de radiografias, onde duas radiografias odontológicas, tiradas em intervalos de tempos planejados, são subtraídas para obter uma nova imagem onde serão visíveis somente estruturas que mudaram de uma imagem em relação à outra. Será gerada uma imagem que auxiliará o dentista a efetuar um diagnóstico precoce e instituir o melhor plano de tratamento, e assim acompanhar a resposta do tratamento a partir de novas imagens subtraídas. Na fase anterior à subtração, é necessário o alinhamento, para garantir que estruturas idênticas em ambas imagens estejam no mesmo local, e evitando que o resultado da subtração seja errôneo. O alinhamento consiste na marcação de 4 pontos em regiões de alto contraste em ambas as imagens para que a imagem subseqüente seja alinhada em translação e em rotação em relação à primeira. Posteriormente, uma técnica de correção de contraste é utilizada para corrigir eventuais diferenças de contraste. A subtração fornecerá três formas de visualização, na imagem subtraída, da área onde ocorreu uma reabsorção ou ganho ósseo. Uma delas é a subtração qualitativa, cujas áreas onde as imagens se mantiveram idênticas são mostradas em preto, e áreas onde ocorreram mudanças, em branco. A segunda é a subtração quantitativa, que gera a imagem subtraída em níveis de cinza, mostrando em tons de cinza uniformes áreas onde as imagens se mantiveram idênticas; em tons de cinza escuros, onde ocorreu reabsorção óssea; e em tons de cinza claros, onde ocorreu ganho ósseo. Além destas duas subtrações, há uma terceira subtração, a subtração quantitativa porcentagem-colorida, que mostrará a porcentagem de reabsorção ou ganho ósseo através de áreas coloridas na imagem. O intervalo de porcentagens poderá ser escolhido pelo dentista e a este intervalo poderá ser atribuída uma cor para visualização. Intervalos de porcentagens negativas indicam reabsorção óssea e intervalos de porcentagens positivas, ganho ósseo. Os testes realizados encontraram um erro médio de 7,5% no resultado da subtração, sendo que deste total, 3,5% é o erro introduzido pelo digitalizador. É importante ressaltar que esta taxa representa o erro não somente do algoritmo desenvolvido, mas também a propagação do erro em todas as etapas do processo, ou seja, aquisição, digitalização, alinhamento e subtração. Portanto, o erro da subtração deduzido do erro do digitalizador é de somente 4,0%. / Radiography is one of the primary features to help diagnose and monitor the treatment of periodontal diseases. However, the subjective analysis of these radiographs by the dentist only can identify lesions above 30% of mineral bone loss, leading to a serious challenge for the practice of odontology. In many clinical situations, the dentist needs to quantify the size of a lesion to determine the rate of progression or healing the disease. The digital subtraction radiography technique provides the detection of subtle bone changes, i.e., changes of around 5%, leading to an early diagnosis and enlarging the success of its treatment. The aided diagnosis scheme for periodontal bone resorption through odontological digital subtraction radiography proposed in this work employees the digital subtraction radiography technique, where two odontologic radiographs taken at intervals of planned times are subtracted to obtain a new image where only structures that have been changed from one image to the other will be visible. It will generate an image to help the dentist make an early diagnosis and establish the best treatment plan, besides accompanying the treatment’s response starting from new subtracted images. In the stage previous to the subtraction, the lining up is necessary to assure that identical structures on both images are in the same place, avoiding an erroneous result of the subtraction. It consists in marking 4 points in places with high contrast on both images for the subsequent image to be first lined up in translation and then in rotation in relation to the first one. Then, a contrast correction technique is used to correct possible contrast differences. The subtraction will provide three ways of visualization in the subtracted image of the area where a bone resorption or gain occurred. One of them is the qualitative subtraction, where areas kept identical are showed in black and areas where changes occurred are showed white. The second is the quantitative subtraction, which generates a subtracted image in gray levels, showing in uniform gray levels the areas where the images remained identical, in dark gray levels the areas where there was bone resorption and in light gray levels the area with bone gain. The third subtraction is called colored-percentage quantitative subtraction, which shows the percentage of bone resorption or gain through colored areas on the radiograph. The intervals of percentage can be chosen by the dentist and he/she can attribute a color for visualization to this interval. Negative percentage intervals indicate bone resorption and positive percentage intervals correspond to bone gain. The tests performed found a mean error of 7.5% in the result of the subtraction, of which 3.5% correspond to the error introduced by the digitalizer. It is important to stress that this rate represents the error not only for the algorithm developed, but the spreading of the error to all process stages, such as acquisition, digitalization, lining up and subtraction. Therefore, the subtraction error deduced from the digitalizer error is only 4,0%.
12

Esquema de auxílio ao diagnóstico de reabsorção óssea periodontal através de subtração digital de radiografias odontológicas / Aided diagnosis scheme for periodontal bone resorption through odontological digital subtraction radiography

Rodrigues, Eveline Batista 09 August 2006 (has links)
A radiografia é uma das ferramentas primárias de auxílio ao diagnóstico e monitoração do tratamento das doenças periodontais. Porém, a análise subjetiva dessas radiografias feita pelo dentista só consegue identificar lesões quando o quadro clínico apresenta perda acima de 30% do conteúdo mineral do osso, levando um sério desafio ao exercício da odontologia. Em muitas situações clínicas, o dentista também precisa ser capaz de quantificar o tamanho de uma lesão para determinar a taxa de progressão ou cura da doença. A técnica de subtração digital de radiografias provê a detecção de mudanças ósseas sutis, de cerca de 5%, levando ao diagnóstico precoce da doença e aumentando assim o sucesso de seu tratamento. Desta forma, o esquema de auxílio ao diagnóstico de reabsorção óssea periodontal através de subtração digital de radiografias odontológicas proposto no presente trabalho emprega a técnica de subtração digital de radiografias, onde duas radiografias odontológicas, tiradas em intervalos de tempos planejados, são subtraídas para obter uma nova imagem onde serão visíveis somente estruturas que mudaram de uma imagem em relação à outra. Será gerada uma imagem que auxiliará o dentista a efetuar um diagnóstico precoce e instituir o melhor plano de tratamento, e assim acompanhar a resposta do tratamento a partir de novas imagens subtraídas. Na fase anterior à subtração, é necessário o alinhamento, para garantir que estruturas idênticas em ambas imagens estejam no mesmo local, e evitando que o resultado da subtração seja errôneo. O alinhamento consiste na marcação de 4 pontos em regiões de alto contraste em ambas as imagens para que a imagem subseqüente seja alinhada em translação e em rotação em relação à primeira. Posteriormente, uma técnica de correção de contraste é utilizada para corrigir eventuais diferenças de contraste. A subtração fornecerá três formas de visualização, na imagem subtraída, da área onde ocorreu uma reabsorção ou ganho ósseo. Uma delas é a subtração qualitativa, cujas áreas onde as imagens se mantiveram idênticas são mostradas em preto, e áreas onde ocorreram mudanças, em branco. A segunda é a subtração quantitativa, que gera a imagem subtraída em níveis de cinza, mostrando em tons de cinza uniformes áreas onde as imagens se mantiveram idênticas; em tons de cinza escuros, onde ocorreu reabsorção óssea; e em tons de cinza claros, onde ocorreu ganho ósseo. Além destas duas subtrações, há uma terceira subtração, a subtração quantitativa porcentagem-colorida, que mostrará a porcentagem de reabsorção ou ganho ósseo através de áreas coloridas na imagem. O intervalo de porcentagens poderá ser escolhido pelo dentista e a este intervalo poderá ser atribuída uma cor para visualização. Intervalos de porcentagens negativas indicam reabsorção óssea e intervalos de porcentagens positivas, ganho ósseo. Os testes realizados encontraram um erro médio de 7,5% no resultado da subtração, sendo que deste total, 3,5% é o erro introduzido pelo digitalizador. É importante ressaltar que esta taxa representa o erro não somente do algoritmo desenvolvido, mas também a propagação do erro em todas as etapas do processo, ou seja, aquisição, digitalização, alinhamento e subtração. Portanto, o erro da subtração deduzido do erro do digitalizador é de somente 4,0%. / Radiography is one of the primary features to help diagnose and monitor the treatment of periodontal diseases. However, the subjective analysis of these radiographs by the dentist only can identify lesions above 30% of mineral bone loss, leading to a serious challenge for the practice of odontology. In many clinical situations, the dentist needs to quantify the size of a lesion to determine the rate of progression or healing the disease. The digital subtraction radiography technique provides the detection of subtle bone changes, i.e., changes of around 5%, leading to an early diagnosis and enlarging the success of its treatment. The aided diagnosis scheme for periodontal bone resorption through odontological digital subtraction radiography proposed in this work employees the digital subtraction radiography technique, where two odontologic radiographs taken at intervals of planned times are subtracted to obtain a new image where only structures that have been changed from one image to the other will be visible. It will generate an image to help the dentist make an early diagnosis and establish the best treatment plan, besides accompanying the treatment’s response starting from new subtracted images. In the stage previous to the subtraction, the lining up is necessary to assure that identical structures on both images are in the same place, avoiding an erroneous result of the subtraction. It consists in marking 4 points in places with high contrast on both images for the subsequent image to be first lined up in translation and then in rotation in relation to the first one. Then, a contrast correction technique is used to correct possible contrast differences. The subtraction will provide three ways of visualization in the subtracted image of the area where a bone resorption or gain occurred. One of them is the qualitative subtraction, where areas kept identical are showed in black and areas where changes occurred are showed white. The second is the quantitative subtraction, which generates a subtracted image in gray levels, showing in uniform gray levels the areas where the images remained identical, in dark gray levels the areas where there was bone resorption and in light gray levels the area with bone gain. The third subtraction is called colored-percentage quantitative subtraction, which shows the percentage of bone resorption or gain through colored areas on the radiograph. The intervals of percentage can be chosen by the dentist and he/she can attribute a color for visualization to this interval. Negative percentage intervals indicate bone resorption and positive percentage intervals correspond to bone gain. The tests performed found a mean error of 7.5% in the result of the subtraction, of which 3.5% correspond to the error introduced by the digitalizer. It is important to stress that this rate represents the error not only for the algorithm developed, but the spreading of the error to all process stages, such as acquisition, digitalization, lining up and subtraction. Therefore, the subtraction error deduced from the digitalizer error is only 4,0%.
13

\"Estudo prospectivo dos parâmetros periodontais e peri-implantares dos pilares que recebem prótese dento-implanto-suportada\" / Prospective study of periodontal and peri-implant parameters of the pillars receiving an implant supported dental prosthesis

Vicente José Muratore de Lima 18 September 2006 (has links)
Desde a introdução dos implantes na Odontologia, controvérsias tem havido acerca da propriedade de conectar os implantes a dentes em próteses fixas. Os implantes osseointegrados não apresentam nenhum ligamento periodontal e são mais firmemente ancorados ao osso. A diferença apresentada nesta ancoragem tem levantado preocupações acerca de o implante osseointegrado, por sua firme fixação ao osso, apresentar pouca flexibilidade para dividir as cargas funcionais com os dentes conectados. O presente estudo teve como propósito acompanhar prospectivamente os parâmetros periodontais ? índice gengival, índice de sangramento, profundidade de sondagem e perda de inserção entre o dente pilar de uma prótese dento-implanto-suportada com o dente colateral do mesmo paciente, e também os parâmetros peri-implantares dos implantes que suportam estas próteses - índice gengival; índice de sangramento; profundidade de sondagem e perda de inserção. Para verificar a perda de inserção foi utilizado o recurso da subtração radiográfica da região em que a prótese foi instalada, com tomadas radiográficas efetuadas no momento da instalação da prótese, decorridos seis meses e após 12 meses de uso, com o objetivo de verificar a ocorrência, ou não, de alteração do suporte ósseo peri-implantar. Foram selecionados 12 pacientes com estado de saúde normal, apresentando área posterior de mandíbula edêntula onde estava indicada a reabilitação protética por meio de prótese fixa unindo dente a implante. Estes foram tratados com implante de um estágio de 10 mm padrão da Straumann (ITI), que apresenta um pescoço polido de 2.8mm, onde a porção do implante que permanece intra-óssea apresenta uma superfície tratada, com diâmetro de 4.1mm. O implante foi instalado no espaço onde se localizaria o retentor mais distal da futura prótese parcial fixa, seguindo o protocolo. As radiografias digitais obtidas foram avaliadas num software de subtração radiográfica, Matrox Inspector versão oito, para verificar a alteração da variação de densidade óptica e contraste das radiografias quando superpostas, sendo os valores observados no implante comparados com os critérios de sucessos , amplamente abordados nos estudos verificados. Todos os implantes instalados nos pacientes osseointegraram, não houve registro de alteração óssea ao redor dos mesmos e nos dentes pilares das próteses em avaliações feitas após seis meses e 12 meses. As próteses continuaram clinicamente em excelente estado após 12 meses de avaliação nas análises clínicas e radiográficas. Ainda, de acordo com o teste de Sinais de Postos de ilcoxon, concluiu-se estatisticamente que não houve diferença nos parâmetros peri-implantares de cada paciente durante os períodos analisados (zero, seis meses e 12 meses), bem como quando comparados com os respectivos dentes colaterais. / Since the introduction of implants in Dentistry, controversies have arisen about the possibility of connecting implants to teeth in fixed prostheses. Osseointegrated implants do no present any periodontal ligature and are more firmly anchored to the bone. The difference presented by this type of anchorage has led to some concern about the limited flexibility of the osseointegrated implant to share the functional loads with the connected teeth. This study intended to follow-up prospectively the periodontal parameters bleeding index, probing depth between the pillar tooth of an implant supported prosthesis with one control tooth of the same patient and also the implants that support theses prostheses. That is why subtraction radiography of the region in which the prosthesis was placed was used, with radiographs taken at prosthesis placement, after six months and one year of use to verify if the periimplant osseous support had or had not undergone changes. Twelve patients with normal health conditions were selected who presented a posterior area edentulous jaw where a prosthetic rehabilitation by a fixed prosthesis joining tooth to implant was indicated. Patients were treated with an implant of one stage of 10mm standard Straumann (ITI) with a 2.8 mm polished neck, in which the remaining intraosseous portion of the implant has a treated surface of 4.1 mm diameter. The implant was placed in the space where according to the protocol, the more distal retainer of the future fixed partial prosthesis would be located. Digital radiographs were assessed with a subtraction radiography software Matrox Inspector version eight, to corroborate the change of contrast in the radiographs when superimposed, with values observed in the implant compared with the success criteria , widely mentioned in surveyed studies. All implants placed in patients became osseointegrated. There was no record of bone change around them and in the dental pillars of the prostheses at the one year follow-up. Prostheses continue to be in excellent conditions after the one year follow-up based upon clinical and radiographic analyses. Furthermore, in accordance with the Wilcoxon test of matched pairs and signed rank, it was concluded that there was no statistical difference between each group of each patient during the time period analyzed (baseline and one year) as well as when the pillars were compared to their respective controls.
14

Estudo longitudinal de lesões profundas de cárie após a remoção incompleta da dentina cariada: 36-45 meses de acompanhamento / Study of deep caries lesions after incomplete dentine caries removal: 36-45 months follow-up study

Oliveira, Elenara Ferreira de 16 October 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:11Z (GMT). No. of bitstreams: 1 Tese _ Elenara_Ferreira_ Oliveira.pdf: 694369 bytes, checksum: 410d5111d12d3fad68258a97ba292b1b (MD5) Previous issue date: 2006-10-16 / This paper assesses clinical/radiographic changes after incomplete carious dentine removal and tooth sealing. 32 teeth with deep caries lesions were studied. The treatment consisted of incomplete excavation, application of Ca (OH)2 layer, sealing for a 6-7 month period, and then restored. Standardized bitewing radiographs were taken after the temporary sealing, and at 6-7, 14-18, and 36-45 month intervals. The digitized images were analyzed: qualitatively in regard to the radiolucent zone (RZ) depth and tertiary dentine (6-7 and 36-45 months) and quantitatively in regard toradiographic density by image subtraction (6-7, 14-18, and 36-45 months). The subtractions were performed in the RZ beneath the restoration and in two control areas (CA). During the 6-7 month period, there was 1 pulp necroses and 1 pulpexposure, and at the 36-45 month interval, 3 fractures and 3 withdrawals. Nine cases showed a decrease in RZ depth in the 6-7 month period and 3 more cases, at the 36- 45 month period. Four cases displayed tertiary dentine. The radiographic density means and standard deviations were: 129.42±5.83, 127.65±4.67, and 126.86±7.03 (CA, P>0.05) and 132.96 ±7.41, 132.90±5.99, and 132.62±8.68 (RZ, P>0.05) for the 1st, 2nd, and 3rd periods. The radiographic density of the CA differed from the RZ (Tukey test, p<0.05). Interference in microbiological metabolism by partial dentine removal and by tooth sealing arrest lesion progression, suggesting that complete dentine caries removal is not essential to controlling caries progression. / Este trabalho avaliou alterações clínicas/radiográficas após a remoção incompleta da dentina cariada e selamento do dente. Trinta e dois dentes com lesões profundas de cárie foram estudados. O tratamento consistiu da escavação incompleta da dentina cariada, aplicação de uma camada de cimento de Ca(OH)2, selamento provisório por um período de 6-7 meses, e restauração. Radiografias interproximais foram feitas logo após o selamento temporário e em intervalos de 6-7, 14-18, e 36-45 meses. As imagens digitalizadas foram analisadas: qualitativamente em relação à profundidade da zona radiolúcida (ZR) e deposição de dentina terciária (6-7 e 36-45 meses) e quantitativamente, em relação à densidade radiográfica, através da subtração de imagem (6-7, 14-18, e 36-45 meses). As subtrações foram realizadas na ZR, abaixo da restauração, e em duas áreas controles (AC). Durante período de 6-7 meses houve uma necrose e uma exposição pulpar, e no intervalo de 36-45 meses, três fraturas e três perdas de pacientes. Nove casos mostraram uma diminuição da profundidade da ZR no período de 6-7 meses e mais três casos no intervalo de 36-45 meses. Em quatro casos foi observada a deposição de dentina terciária. As médias de densidade radiográfica e desvio-padrão foram: 129.42±5.83, 127.65±4.67, e 126.86±7.03 (AC, p>0.05) e 132.96±7.41, 132.90±5.99, e 132.62±8.68 (ZR, p>0.05) para o 1º, 2º e 3º períodos, respectivamente. A densidade radiográfica das AC foi diferente da ZR (teste de Tukey, p<0.05). A interferência no metabolismo microbiano promovida pela remoção parcial da dentina cariada e selamento do dente provocou a paralisação da lesão, sugerindo que a remoção completa da dentina cariada não é essencial para o controle da progressão da cárie.
15

Avaliação radiográfica dos efeitos da carga oclusal excessiva sobre implantes dentários SLA e SLActive restaurados precocemente: estudo experimental em cães / Radiographic evaluation of the effects of an excessive oclusal load on early restored SLA and SLAactive dental implants: an experimental study in dogs

Chambrone, Leandro 01 February 2012 (has links)
O objetivo deste estudo foi avaliar os resultados radiográficos obtidos pelas analises de subtração radiográfica digital e linear de implantes dentários com superfície SLA e SLActive submetidos a carga funcional e sobrecarga oclusal precoce restaurados com reconstruções em cantilever (pôntico suspenso). Cinco cães beagle tiveram seus pré-molares mandibulares extraídos bilateralmente. Após três meses, retalhos foram elevados e seis implantes (três SLA e três SLActive) foram instalados em um desenho de boca dividida e aleatorização por blocos. Após quatro semanas, os implantes foram restaurados em cada lado da mandíbula da seguinte forma: uma coroa unitária com contatos oclusais estáveis (OE), uma coroa e uma unidade de cantilever com contatos oclusais excessivos (SO), e um implante protegido pela unidade em cantilever que não recebeu carga funcional (NR). Os cães foram mantidos em um programa de controle de placa periódico, durante o período do experimento. Radiografias padronizadas foram tomadas utilizando-se guias radiográficas individualizadas e padronizadas em dois momentos: na instalação das próteses e 24 semanas após o carregamento. Análises de subtração radiográfica digital e medições lineares (entre um plano projetado entre os ombros do implante e o primeiro contato implante-osso) foram realizadas. As análises estatísticas, ANOVA para medidas repetidas, ANOVA para dados equilibrados e teste t de Bonferroni foram utilizados para identificar diferenças entre as médias, entre os seis grupos avaliados: SLA OE, SLA SO, SLA NR, SLActive OE, SLActive SO e SLActive NR. Achados gerais similares foram observados para os grupos SLA e SLActive (todos os grupos OE, NR e SO) em relação ao nível ósseo peri-implantar e as dimensões das áreas indicando alterações de densidade óssea ao redor dos implantes. As mensurações lineares variaram de 1,61 mm (grupo SLActive SO) a 1,94 mm (grupo SLA SO) no tempo 0 (antes da aplicação das cargas funcionais) e 2,00 mm (grupo SLA SO) a 2,99 mm (grupo SLActive NR) na avaliação após 24 semanas, sem diferenças estatisticamente significativas dentro ou entre-grupos (p = 0,672). Com relação à área de mudança de densidade óssea, esta variou de 0,91 mm2 (grupo SLA OE) para 1,40 mm2 (grupo SLA SO), mas sem diferenças significativas entre os grupos (p = 0,568). Por outro lado, um ganho de densidade óssea estatisticamente significativa foi encontrado para o grupo SLA com sobrecarga oclusal (p = 0,012). Nenhuma diferença significativa na alteração de densidade óssea foi detectada entre os outros cinco grupos (p> 0,05). Em conclusão, a sobrecarga oclusal precoce aplicada sobre implantes restaurados com reconstruções em cantilever, não levou a mudanças significativas na altura óssea peri-implantar após 24 semanas. No entanto, a densidade óssea ao redor de implantes SLA com sobrecarga oclusal, foi significativamente maior que nos outros grupos. / The objective of this study was to evaluate the radiographic outcomes of SLA and SLActive dental implants submitted to functional load and early occlusal overload restored with cantilever reconstructions. Five beagle dogs had their mandibular premolars extracted bilaterally. After three months, flaps were raised and six implants (three SLA and three SLActive) were installed in a block-randomized split-mouth design. After four weeks, implants were restored on each side of the mandible as follows: one single crown with stable occlusal contacts (OE), one crown and a cantilever unit with overt occlusal contacts (SO), and an implant protected by the cantilever unit not submitted to functional load (NR). The dogs were maintained in a strict and periodic plaque control program during the period of the experiment. Standardized radiographies were taken using standardized and individualized radiographic stents in two distinct moments: at prostheses installation and 24-weeks after loading. Digital subtraction radiography analyses and linear measurements were performed. Statistical analyses used repeated measures ANOVA and ANOVA for balanced data and the Bonferroni Student t test to identify differences between the means of the six evaluated groups: SLA OE, SLA SO, SLA NR, SLActive OE, SLActive SO and SLActive NR. Similar findings were found for SLA and SLActive groups regarding the peri-implant bone level and the area of bone density change around implants. Baseline linear measurements ranged from 1.61 mm (SLActive SO group) to 1.94 mm (SLA SO group) at baseline, and from 2.00 mm (SLA SO group) to 2.99 mm (SLActive NR group) at the 24-week evaluation, with no statistically significant differences within- or between-groups (p=0.672). With respect to the areas of bone density change, they ranged from 0.91 mm2 (SLA OE group) to 1.40 mm2 (SLA SO group), but without significant differences between groups (p=0.568). On the other hand, a statistically significant bone density gain was found for the overloaded SLA group (p=0.012). No significant differences in bone density change were detected between the other five groups (p>0.05). In conclusion, the early occlusal overload applied to implants restored with cantilever reconstructions did not lead to significant changes in the peri-implant bone height. However, bone density around overloaded SLA implants was significantly higher than in the other groups.
16

Avaliação radiográfica dos efeitos da carga oclusal excessiva sobre implantes dentários SLA e SLActive restaurados precocemente: estudo experimental em cães / Radiographic evaluation of the effects of an excessive oclusal load on early restored SLA and SLAactive dental implants: an experimental study in dogs

Leandro Chambrone 01 February 2012 (has links)
O objetivo deste estudo foi avaliar os resultados radiográficos obtidos pelas analises de subtração radiográfica digital e linear de implantes dentários com superfície SLA e SLActive submetidos a carga funcional e sobrecarga oclusal precoce restaurados com reconstruções em cantilever (pôntico suspenso). Cinco cães beagle tiveram seus pré-molares mandibulares extraídos bilateralmente. Após três meses, retalhos foram elevados e seis implantes (três SLA e três SLActive) foram instalados em um desenho de boca dividida e aleatorização por blocos. Após quatro semanas, os implantes foram restaurados em cada lado da mandíbula da seguinte forma: uma coroa unitária com contatos oclusais estáveis (OE), uma coroa e uma unidade de cantilever com contatos oclusais excessivos (SO), e um implante protegido pela unidade em cantilever que não recebeu carga funcional (NR). Os cães foram mantidos em um programa de controle de placa periódico, durante o período do experimento. Radiografias padronizadas foram tomadas utilizando-se guias radiográficas individualizadas e padronizadas em dois momentos: na instalação das próteses e 24 semanas após o carregamento. Análises de subtração radiográfica digital e medições lineares (entre um plano projetado entre os ombros do implante e o primeiro contato implante-osso) foram realizadas. As análises estatísticas, ANOVA para medidas repetidas, ANOVA para dados equilibrados e teste t de Bonferroni foram utilizados para identificar diferenças entre as médias, entre os seis grupos avaliados: SLA OE, SLA SO, SLA NR, SLActive OE, SLActive SO e SLActive NR. Achados gerais similares foram observados para os grupos SLA e SLActive (todos os grupos OE, NR e SO) em relação ao nível ósseo peri-implantar e as dimensões das áreas indicando alterações de densidade óssea ao redor dos implantes. As mensurações lineares variaram de 1,61 mm (grupo SLActive SO) a 1,94 mm (grupo SLA SO) no tempo 0 (antes da aplicação das cargas funcionais) e 2,00 mm (grupo SLA SO) a 2,99 mm (grupo SLActive NR) na avaliação após 24 semanas, sem diferenças estatisticamente significativas dentro ou entre-grupos (p = 0,672). Com relação à área de mudança de densidade óssea, esta variou de 0,91 mm2 (grupo SLA OE) para 1,40 mm2 (grupo SLA SO), mas sem diferenças significativas entre os grupos (p = 0,568). Por outro lado, um ganho de densidade óssea estatisticamente significativa foi encontrado para o grupo SLA com sobrecarga oclusal (p = 0,012). Nenhuma diferença significativa na alteração de densidade óssea foi detectada entre os outros cinco grupos (p> 0,05). Em conclusão, a sobrecarga oclusal precoce aplicada sobre implantes restaurados com reconstruções em cantilever, não levou a mudanças significativas na altura óssea peri-implantar após 24 semanas. No entanto, a densidade óssea ao redor de implantes SLA com sobrecarga oclusal, foi significativamente maior que nos outros grupos. / The objective of this study was to evaluate the radiographic outcomes of SLA and SLActive dental implants submitted to functional load and early occlusal overload restored with cantilever reconstructions. Five beagle dogs had their mandibular premolars extracted bilaterally. After three months, flaps were raised and six implants (three SLA and three SLActive) were installed in a block-randomized split-mouth design. After four weeks, implants were restored on each side of the mandible as follows: one single crown with stable occlusal contacts (OE), one crown and a cantilever unit with overt occlusal contacts (SO), and an implant protected by the cantilever unit not submitted to functional load (NR). The dogs were maintained in a strict and periodic plaque control program during the period of the experiment. Standardized radiographies were taken using standardized and individualized radiographic stents in two distinct moments: at prostheses installation and 24-weeks after loading. Digital subtraction radiography analyses and linear measurements were performed. Statistical analyses used repeated measures ANOVA and ANOVA for balanced data and the Bonferroni Student t test to identify differences between the means of the six evaluated groups: SLA OE, SLA SO, SLA NR, SLActive OE, SLActive SO and SLActive NR. Similar findings were found for SLA and SLActive groups regarding the peri-implant bone level and the area of bone density change around implants. Baseline linear measurements ranged from 1.61 mm (SLActive SO group) to 1.94 mm (SLA SO group) at baseline, and from 2.00 mm (SLA SO group) to 2.99 mm (SLActive NR group) at the 24-week evaluation, with no statistically significant differences within- or between-groups (p=0.672). With respect to the areas of bone density change, they ranged from 0.91 mm2 (SLA OE group) to 1.40 mm2 (SLA SO group), but without significant differences between groups (p=0.568). On the other hand, a statistically significant bone density gain was found for the overloaded SLA group (p=0.012). No significant differences in bone density change were detected between the other five groups (p>0.05). In conclusion, the early occlusal overload applied to implants restored with cantilever reconstructions did not lead to significant changes in the peri-implant bone height. However, bone density around overloaded SLA implants was significantly higher than in the other groups.

Page generated in 0.1331 seconds