Spelling suggestions: "subject:"burface properties "" "subject:"1surface properties ""
51 |
Untersuchungen über das Dimensionsverhalten zahnärztlicher HartgipseFranz, Gertraute. January 1978 (has links)
Habilitationsschrift--Hamburg. / Includes bibliographical references (p. [111]-116).
|
52 |
Endothelial cell interactions with model surfaces : effect of surface chemistry, surface mobility, and the adsorbed protein layer /Tidwell, Caren Diana. January 1999 (has links)
Thesis (Ph. D.)--University of Washington, 1999. / Vita. Includes bibliographical references (leaves 278-286).
|
53 |
Estudo de implantes de Ticp com superfícies modificadas por feixe de laser com e sem deposição química de apatitas: análises topográfica, biomecânica e histométrica em coelhosQueiroz, Thallita Pereira [UNESP] 16 April 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-04-16Bitstream added on 2014-06-13T19:01:26Z : No. of bitstreams: 1
queiroz_tp_dr_araca.pdf: 6726778 bytes, checksum: 065d55c84b04f648183adf1b94784bd6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O sucesso da reabilitação com implantes osseointegráveis é dependente de vários fatores, destacando-se as propriedades físico-químicas da superfície, que interferem nas respostas biológicas e conseqüente reparo ósseo da interface osso/implante. O propósito deste estudo foi avaliar as superfícies de implantes de titânio comercialmente puro (Ticp) modificadas por feixe de laser (SL) sem e com deposição de hidroxiapatita pelo método biomimético, sem (SHAST) e com tratamento térmico (SHACT), comparando-as com implantes de superfície modificada por tratamento ácido (SA) e com superfície usinada (SU), empregando-se análises topográfica, biomecânica e histométrica. Quarenta e cinco coelhos receberam 150 implantes, sendo 2 implantes de cada superfície por tíbia. Após 30, 60 e 90 dias, os animais foram submetidos à eutanásia e os implantes localizados superiormente foram expostos, removidos por torque-reverso para análise biomecânica e as superfícies foram analisadas topograficamente. O implante localizado mais inferiormente em cada tíbia foi removido com o tecido ósseo ao redor e processado para obtenção de cortes histológicos não-descalcificados para análise histométrica da extensão linear de contato osso/implante (ELCOI) e da área óssea (AO) entre as espiras da região cortical superior. Aos 30 e 60 dias, os grupos SL, SHAST, SHACT e SA apresentaram valores de torque-reverso estatisticamente superiores (p<0,05) ao torque de SU. Aos 30 dias, os grupos SHAST e SHACT foram estatisticamente superiores ao grupo SA e o grupo SHAST foi superior ao SL. Aos 90 dias a diferença foi observada somente entre SHAST e SU. A análise topográfica revelou diferença estatística significante (p<0,05) entre a rugosidade de SL, SHAST e SHABT quando comparadas com SA e SU. A análise histométrica da ELCOI mostrou... / The success of rehabilitation with dental implants is dependent on several factors, highlighting the physical and chemical properties of the implant surface, which interfere with the biological responses and subsequent bone repair of bone-implant interface. The purpose of this study was to evaluate the surfaces of implants of commercially pure titanium (cp Ti) modified by laser beam (LS) with and without hydroxyapatite deposition by the biomimetic method, without (HAB) and with thermal treatment (HABT) comparing them with implants surface modified by treatment with acid (AS) and machined surface (MS), employing topographical, biomechanics and histometric analysis. Forty-five rabbits received 150 implants (2 implants of each surface in each tibia). After 30, 60 and 90 days, the animals were euthanized and the implants superiorly located were exposed, removed by removal torque for biomechanical analysis and the surfaces were examined topographically. The implant located more inferiorly in each tibia was removed with the bone tissue around and it was processed to obtain non-decalcified histological sections for histometric analysis of the percentage of bone-implant contact (BIC) and bone area (BA) between the threads of higher cortical. At 30 and 60 days, the groups LS, HAB, HABT and AS obtained removal torque values statistically superior (p <0.05) than the removal torque of MS. At 30 days, the HAB and HABT groups were statistically superior to the AS group and HAB was higher than LS. At 90 days, HAB was statistically significant different from MS. The topographical analysis showed statistically significant difference (p <0.05) between the roughness of LS, HAB and HABT when compared with AS and MS. The histometric analysis of BIC showed that LS, HAB and HABT were statistically superior to the AS and MS, in three... (Complete abstract click electronic access below)
|
54 |
Desenvolvimento e avaliação da efetividade de duas pastas polidoras em padrão nanométrico empregadas a materiais restauradores estéticos: análise comparativa por perfilometria digital e microscopia de força atômicaElossais, André Afif [UNESP] 28 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-03-28Bitstream added on 2014-06-13T21:02:28Z : No. of bitstreams: 1
elossais_aa_dr_arafo.pdf: 996142 bytes, checksum: 88037f1a3f60e9e1dfbc58af37913bed (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Considerando a recente introdução de resinas nanoparticuladas no mercado odontológico, este trabalho teve o propósito de desenvolver duas pastas polidoras em padrão nanométrico e estudar os tratamentos superficiais e técnicas de polimento comumente empregadas para as diferentes resinas já disponíveis e também para esses novos produtos. Foram confeccionados 40 corpos-de-prova para cada resina composta: Vit-l-escence™ – microhíbrida (M1) e Filtek™ Z350 – nanoparticulada ou nanoaglomerada (M2). As amostras foram armazenadas por 24 horas em água destilada a 37_C + 1_C, para então serem submetidas ao tratamento superficial, onde a rugosidade média (Ra) foi analisada em quatro etapas consecutivas: Grupo Controle – T0 (Controle A – tira de poliéster Mylar™ e Controle B – Pincel Hot Spot™ Design); polimento com o sistema de discos abrasivos – T1 (Sof-Lex Pop On™); polimento com pastas abrasivas em padrão micrométrico – T2 (Diamond Polish Paste™ e Enamelize™) e polimento com pastas abrasivas nanométricas – T3 (Lummina-E Diamond e Lummina-E Alumina). Os resultados obtidos revelaram que, em todas as etapas observadas, as resinas compostas exibiram valores de rugosidade média muito satisfatória, sendo que a resina composta M1 alcançou os menores valores. Quando empregada a Tira de Poliéster Mylar™ como Grupo Controle (Controle A), os menores valores de rugosidade média foram inqüestionavelmente observados na etapa T0. Quando empregados os discos abrasivos Sof-Lex Pop On™ (etapa T1), a rugosidade média das amostras aumentou significativamente quando comparado à etapa T0 (Grupo Controle A – Tira de Poliéster Mylar™). Ao se eliminar a etapa T1 do Grupo Controle B (Pincel Hot Spot Design™), na etapa T2 os valores de rugosidade média diminuíram substancialmente, porém, continuaram superiores àqueles obtidos pelo Controle A e também pelo... / Considering the recent introduction of nanocluster resin-based materials in dentistry market, this work had the intention to develop two nanometricpatterned polish pastes and to also evaluate whether the polishing techniques commonly used, and which feature satisfactory results for the different resins already available, are appropriate for these new products. Fourty test specimens were fabricated for each composite resin: Vit-lescence ™ – micro-hybrid particles (M1) and Filtek™ Z350 – nanoparticled or nanocluster (M2). The samples were stored within distilled water at 37_C + 1_C by 24 hours and submitted to surface treatment, where the mean roughness was assessed in four consecutive phases: control – T0 (standardization with polyester matrix bands and Hot Spot Design™ brush); polishing with abrasive disc system – T1 (Sof-Lex Pop On™); polishing with micro-patterned polishing pastes – T2 (Diamond Polish Paste™ and Enamelize™) and polishing with nano-patterned polishing pastes – T3 (Lummina-E Diamond and Lummina-E Alumina). Obtained results showed that, in all the phases observed, the composite resins featured rather satisfactory mean roughness scores, where composite resin M1 reached the lowest scores. It was demonstrated that the lowest mean roughness scores were unquestionably observed in phase T0 for all the composite resins, where the test specimens’ standardization was performed with polyester matrix bands (control group). When the abrasive discs were used (phase T1), the samples mean roughness had a significant increase when compared to phase T0. When phase T1 was eliminated in Control Group B (Hot Spot Design™ brush), in the phase T2 mean roughness values had decreased substantially, however, they had continued higher compared to Control A and B. In phase T2 (polishing with micro-patterned pastes) mean roughness values also decreased compared to phase... (Complete abstract click electronic access below)
|
55 |
Avaliação das propriedades de superfície de ligas de titânio anodizadas com elementos bioativos /Reis, Bárbara Araújo dos January 2018 (has links)
Orientador: Luis Geraldo Vaz / Resumo: O titânio comercialmente puro e suas ligas vêm sendo amplamente utilizados para confecção de implantes dentários e ortopédicos devido à adequada resistência mecânica, resistência à corrosão e biocompatibilidade. Entretanto, para aprimorar o tratamento com o uso de implantes, novas ligas e novos tratamentos de superfície vêm sendo pesquisados. A técnica de funcionalização de superfície, baseada em processos úmidos, é amplamente utilizada para desenvolver superfícies a base de óxido de titânio que induza e aumente a osseocondução. Assim, o objetivo deste estudo foi caracterizar a superfície de discos de Ti-6Al-4V e Ti-35Nb-7Zr-Ta após anodização para funcionalização com íons cálcio (Ca) e fósforo (P) ou fluoreto e dopagem com magnésio (Mg++) em diferentes condições experimentais, sendo a liga Ti-6Al-4V utilizada como controle. As ligas foram analisadas antes e após a realização dos tratamentos (anodização e dopagem), para avaliação das propriedades de superfície- composição química, energia livre de superfície (ELS), morfologia/ topografia e rugosidade média (Ra). Para interpretação dos resultados referentes a ELS e Ra foi aplicado teste estatístico por um operador cego, de acordo com o tipo de distribuição e nível de significância de 5%. As micrografias obtidas demonstraram que a anodização com Ca e P propiciou a formação de superfícies com poros interconectados e a anodização com ácido fluorídrico (HF) resultou em superfícies com formação de nanotubos. Todos íons adicionados ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Commercially pure titanium and its alloys have been widely used in the manufacture of dental and orthopedic implants due to adequate mechanical strength, corrosion resistance and biocompatibility. However, to improve the treatment with the use of implants to optimize osseointegration, new alloys and new surface treatments have been researched. The surface functionalization technique, based on wet processes, is widely used to develop titanium oxide based surfaces that induce and increase osseoconduction. The aim of this study was to characterize the surface of Ti-6Al-4V and Ti-35Nb-7Zr-Ta discs after anodization for functionalization with calcium ions (Ca) and phosphorus (P) or fluoride and doping with magnesium (Mg ++) in different experimental conditions. The Ti-6Al-4V alloy was used as a control. The alloys were analyzed before and after the treatments (anodization and doping), to evaluate the surface properties - chemical composition, surface free energy (ELS), morphology / topography and medium roughness (Ra). For the interpretation of the ELS and Ra results, a statistical test was applied according to the type of distribution and level of significance of 5%. The obtained micrographs showed that the anodization with Ca and P allowed the formation of surfaces with interconnected pores and the anodization with hydrofluoric acid resulted in surfaces with formation of nanotubes. All ions added to the electrolytes were incorporated into the samples, detected by ELS. The roughn... (Complete abstract click electronic access below) / Mestre
|
56 |
Influência do selante de superfície em propriedades físicas e mecânicas de resinas compostas submetidas a envelhecimentos artificiaisCatelan, Anderson [UNESP] January 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2009Bitstream added on 2014-06-13T18:51:40Z : No. of bitstreams: 1
catelan_a_me_araca.pdf: 509697 bytes, checksum: 775138bff151daa12592bcd4fc83894b (MD5) / O propósito deste estudo foi avaliar a influência do selante de superfície (Biscover LV, Bisco) na microdureza Knoop, rugosidade de superfície e alteração de cor de resinas compostas microhíbridas e nanoparticulada submetidas a envelhecimentos artificiais. Cem espécimes foram confeccionados para cada resina composta, Supreme XT (3M/Espe), Vit-l-escence (Ultradent) e Opallis (FGM). Após 24h, as superfícies das amostras foram polidas e o selante foi aplicado em 50 amostras de cada compósito. A rugosidade de superfície (Ra) foi determinada com um perfilômetro (SJ-400, Mitutoyo) e cut-off de 0,25mm; a microdureza Knoop foi avaliada em um microdurômetro (HMV-2000, Shimadzu), com carga de 50g durante 15s; e a análise cromática inicial foi avaliada de acordo com o sistema CIE L*a*b* em espectrofotômetro de reflexão (UV-2450, Shimadzu). Após as avaliações iniciais, 10 espécimes de cada grupo foram envelhecidos durante 252h em câmara de envelhecimento acelerado de UV (EQUV, Equilam) ou imersos por 4 semanas em uma das três soluções corantes (refrigerante de cola, suco de laranja ou vinho tinto) ou água destilada como controle. Após os envelhecimentos, as propriedades testadas foram re-avaliadas. Os dados de microdureza, rugosidade, alteração de cor foram analisados pela ANOVA e teste de Fischer (α=0,05). Os envelhecimentos artificiais causaram mudanças de cor em todos os grupos e diminuíram os valores de microdureza para todos os materiais, exceto para os compósitos Vit-l-escence e Supreme XT selados, mas não alteraram os valores de rugosidade. O armazenamento em água destilada teve o menor efeito sobre a microdureza e os menores valores de ΔE comparado com os outros processos de envelhecimento (p<0,05). Os materiais selados apresentaram os menores valores de rugosidade e microdureza comparados aos compósitos não selados. Independente do material estudado... / The purpose of this study was to evaluate the influence of surface sealant (Biscover LV, Bisco) on the Knoop microhardness, surface roughness and color alteration of microhybrids and nanofilled composite resins submitted to artificial aging. One hundred specimens were made for each of the composite resins; Supreme XT (3M/Espe), Vit-l-escence (Ultradent) and Opallis (FGM). After 24h, the samples’ surfaces were polished and sealant was applied to 50 samples of each composite. The surface roughness (Ra) was determined using a perfilometer (SJ-400, Mitutoyo) and cut-off of 0.25mm; the Knoop microhardness was evaluated in a microdurometer (HMV-2000, Shimadzu), with 50g load during 15s; and the initial chromatic analysis was evaluated in accordance with CIE L*a*b* system in reflection spectrophotometer (UV-2450, Shimadzu). After the initial evaluations, 10 specimens of each group were aged during 252h in a UV-accelerated aging chamber (EQUV, Equilam) or immersed for 4 weeks in one of three staining solutions (cola soft drink, orange juice or red wine) or distilled water as control. After aging, the properties tested were reevaluated. The microhardness, surface roughness and color alteration data were analyzed by ANOVA and Fischer’s test (α=0.05). The artificial aging caused color changes in all the groups and decreased the microhardness values for all the materials, except for the Vit-l-escence and Supreme XT sealed composites, but had no effect on the roughness values. The storage in distilled water had the least effect on microhardness and resulted in the lowest values of TE compared with other aging processes (p<0.05). The sealed materials presented the lowest values of surface roughness and microhardness compared to the unsealed composites. Regardless of the material studied, the red wine solution demonstrated the highest level of staining (p<0.0001). Intermediate ΔE values were... (Complete abstract click electronic access below)
|
57 |
Modulação da expressão de miRNAs na diferenciação de osteoblastos em nanosuperfícies / Modulation of miRNA expression in osteoblast differentiation in nanosurfacesSartori, Elisa Mattias [UNESP] 27 April 2016 (has links)
Submitted by ELISA MATTIAS SARTORI null (elisamsartori@gmail.com) on 2016-06-23T20:05:53Z
No. of bitstreams: 1
Elisa Mattias Sartori.pdf: 1436534 bytes, checksum: dd0f5ca15c561bf7bd3853e437fe11ee (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-06-27T18:58:23Z (GMT) No. of bitstreams: 1
sartori_em_dr_arafo.pdf: 1436534 bytes, checksum: dd0f5ca15c561bf7bd3853e437fe11ee (MD5) / Made available in DSpace on 2016-06-27T18:58:23Z (GMT). No. of bitstreams: 1
sartori_em_dr_arafo.pdf: 1436534 bytes, checksum: dd0f5ca15c561bf7bd3853e437fe11ee (MD5)
Previous issue date: 2016-04-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: Este estudo teve como objetivo avaliar a modulação dos miRNAs que afetam o potencial osteogênico de CTMs em diferentes topografias de superfície de discos de vidro. Material e Métodos: Células tronco mesenquimais humanas foram plaqueadas nas diferentes superfícies e comparadas após 3, 7 e 14 dias para atividade de fosfatase alcalina, expressão de genes (Osteocalcina, Osteopontina, Sialo Proteína Óssea, Osterix, Runx2, BMP2 e ALP) e expressão de miRNAs. Microscopia eletrônica de varredura das superfícies com células foram obtidas para avaliação de adesão celular. Resultados: Atividade de fosfatase alcalina nas diferentes superfícies foi significantemente maior na superfície com nanotopografia. Do mesmo modo, a expressão de genes relacionados com osteoblastos foi mais elevada na superfície nano. Com 14 dias foi observado um aumento de 3.5 e 9 vezes para os genes Runx2 e Osterix, respectivamente. O gene da BMP2 e ALP também apresentou um aumento de 4 e 7 vezes comparado ao controle. Utilizando a tecnologia de sequenciamento de RNA (RNA-Seq) onde todos os RNAs existentes foram sequenciados, um total de 123 miRNAs com diferença de expressão foram encontrados comparando a superfície controle (dia 7) com a superfície nano (dia 14). 48 miRNAs apresentaram uma redução na expressão e 75 apresentaram um aumento de expressão. Alguns destes apresentaram marcadores para genes osteogênicos já identificados, tais como hsa-miR-135b-5p marcador para OCN, BSP, Runx2, CO15A1 e OSX, hsa-miR-122-5p marcador para OPN, hsa-miR-196a-5p marcador para BMP4, hsa-miR-26b-5p marcador para BMP2 e hsa-miR-148b-3p marcador para OPN. Conclusão: As superfícies com nanotopografia tem o potencial de melhorar a resposta de osseointegração de maneira a reduzir o tempo de osseointegração e também aumentar a produção de tecido ósseo ao redor dos implantes favorecendo assim áreas de qualidade óssea baixa. A utilização de miRNAs para alterar a resposta de diferenciação pode também ajudar a controlar o processo de osseointegração. / Purpose: This study aimed to evaluate the modulation of miRNAs that affect the osteogenic potential of MSCs in different surface topographies of glass disks. Material and Methods: Human mesenchymal stem cells (hMSCs) were plated on different surfaces of glass disks and compared at 3,7 and 14 days for alkaline phosphatase (ALP) activity, expression of genes (Osteocalcin, Osteopontin, Bone Sialo Protein, Osterix, Runx2, BMP2 and ALP) and expression of miRNAs. Scanning electron microscopy of surfaces with cells were obtained to analyse the attachment of cells. Results: ALP activity on different surfaces was significantly greater in the nanotopography surface. At day 14 there was a 3.5-fold and a 9-fold increase for Runx2 and Osterix gene, respectively. BMP2 and ALP also increased by 4- and 7-fold compared to control. Using RNA sequencing technology (RNA-Seq) a total of 123 miRNAs were found differently expressed comparing control (day 7) to nano surface (day 14). 48 miRNAs were downregulated and 75 were upregulated. Some of them regulated osteogenic genes such as hsa-miR-135b-5p that targets OCN, BSP, RUNX2, CO15A1 and OSX, hsa-miR-122-5p wich targets OPN, hsa-miR-196a-5p targets BMP4, hsa-miR-26b-5p that targets BMP2 and hsa-miR-148b-3p that targets OPN. Conclusion: Surfaces with nanotopography have the potential to improve osseointegration response in order to reduce the time of osseointegration and also increase the production of bone tissue around the implants improving low bone quality areas. The use of miRNAs to affect differentiation response may also help control the osseointegration process. / CAPES: BEX8187/14-2
|
58 |
Desenvolvimento e avaliação da efetividade de duas pastas polidoras em padrão nanométrico empregadas a materiais restauradores estéticos : análise comparativa por perfilometria digital e microscopia de força atômica /Elossais, André Afif. January 2008 (has links)
Resumo: Considerando a recente introdução de resinas nanoparticuladas no mercado odontológico, este trabalho teve o propósito de desenvolver duas pastas polidoras em padrão nanométrico e estudar os tratamentos superficiais e técnicas de polimento comumente empregadas para as diferentes resinas já disponíveis e também para esses novos produtos. Foram confeccionados 40 corpos-de-prova para cada resina composta: Vit-l-escence™ - microhíbrida (M1) e Filtek™ Z350 - nanoparticulada ou nanoaglomerada (M2). As amostras foram armazenadas por 24 horas em água destilada a 37_C + 1_C, para então serem submetidas ao tratamento superficial, onde a rugosidade média (Ra) foi analisada em quatro etapas consecutivas: Grupo Controle - T0 (Controle A - tira de poliéster Mylar™ e Controle B - Pincel Hot Spot™ Design); polimento com o sistema de discos abrasivos - T1 (Sof-Lex Pop On™); polimento com pastas abrasivas em padrão micrométrico - T2 (Diamond Polish Paste™ e Enamelize™) e polimento com pastas abrasivas nanométricas - T3 (Lummina-E Diamond e Lummina-E Alumina). Os resultados obtidos revelaram que, em todas as etapas observadas, as resinas compostas exibiram valores de rugosidade média muito satisfatória, sendo que a resina composta M1 alcançou os menores valores. Quando empregada a Tira de Poliéster Mylar™ como Grupo Controle (Controle A), os menores valores de rugosidade média foram inqüestionavelmente observados na etapa T0. Quando empregados os discos abrasivos Sof-Lex Pop On™ (etapa T1), a rugosidade média das amostras aumentou significativamente quando comparado à etapa T0 (Grupo Controle A - Tira de Poliéster Mylar™). Ao se eliminar a etapa T1 do Grupo Controle B (Pincel Hot Spot Design™), na etapa T2 os valores de rugosidade média diminuíram substancialmente, porém, continuaram superiores àqueles obtidos pelo Controle A e também pelo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Considering the recent introduction of nanocluster resin-based materials in dentistry market, this work had the intention to develop two nanometricpatterned polish pastes and to also evaluate whether the polishing techniques commonly used, and which feature satisfactory results for the different resins already available, are appropriate for these new products. Fourty test specimens were fabricated for each composite resin: Vit-lescence ™ - micro-hybrid particles (M1) and Filtek™ Z350 - nanoparticled or nanocluster (M2). The samples were stored within distilled water at 37_C + 1_C by 24 hours and submitted to surface treatment, where the mean roughness was assessed in four consecutive phases: control - T0 (standardization with polyester matrix bands and Hot Spot Design™ brush); polishing with abrasive disc system - T1 (Sof-Lex Pop On™); polishing with micro-patterned polishing pastes - T2 (Diamond Polish Paste™ and Enamelize™) and polishing with nano-patterned polishing pastes - T3 (Lummina-E Diamond and Lummina-E Alumina). Obtained results showed that, in all the phases observed, the composite resins featured rather satisfactory mean roughness scores, where composite resin M1 reached the lowest scores. It was demonstrated that the lowest mean roughness scores were unquestionably observed in phase T0 for all the composite resins, where the test specimens' standardization was performed with polyester matrix bands (control group). When the abrasive discs were used (phase T1), the samples mean roughness had a significant increase when compared to phase T0. When phase T1 was eliminated in Control Group B (Hot Spot Design™ brush), in the phase T2 mean roughness values had decreased substantially, however, they had continued higher compared to Control A and B. In phase T2 (polishing with micro-patterned pastes) mean roughness values also decreased compared to phase... (Complete abstract click electronic access below) / Orientador: Antonio Carlos Guastaldi / Coorientador: Welingtom Dinelli / Banca: José Roberto Cury Saad / Banca: Luis Geraldo Vaz / Banca: César Antunes de Freitas / Banca: Pedro Gregol da Silva / Doutor
|
59 |
Avaliação da resistência de união de reparos em resinas compostas convencionais e bulkfill /Trevisan, Tamara Carolina. January 2016 (has links)
Orientador: Osmir Batista de Oliveira Junior / Banca: Weber Adad Ricci / banca: Gustavo Moncada / Resumo: Técnicas de reparos de restaurações vêm sendo amplamente utilizadas como um tratamento alternativo e conservador á substituição de restaurações defeituosas. O conhecimento do material a ser reparado e de um protocolo ideal, permitiria uma melhor relação biomecânica entre dente e material restaurador e possibilitaria técnicas eficazes e menos invasivas. O objetivo do presente estudo foi avaliar a resistência de união de reparo de diferentes resinas compostas, sob a influência de tratamentos de superfície, especialmente em relação a uma nova proposta comercial denominada de resinas "bulk fill". Para isso, foram confeccionados corpos de prova com diâmetro de 8mm por 4mm de altura, de diferentes classes de resinas compostas: Z350XT, Z250XT, Grandio, Epricord, Tetric Bulkfill, Xtra Fill e Sonic Fill (n=15). Estes passaram por processo de envelhecimento artificial, realizado por meio de armazenamento em estufa com saliva artificial por 3 meses, sendo realizada a troca da saliva semanalmente, e finalizado com termociclagem 5o e 55ºC por 20 segundos em água para 1000 ciclos. Foram distribuídos aleatoriamente em três subgrupos, de acordo com o tratamento de superfície (n=5): G1- Controle- sem tratamento prévio; G2- Jateamento óxido alumínio; G3- Jateamento óxido de sílica. Após a aplicação dos respectivos tratamentos de superfície, cada espécime foi reparado com resina composta Z100 em incrementos de aproximadamente 2mm e fotopolimerizado em um aparelho de fotopolimerização convencion... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
|
60 |
Estudo de implantes de Ticp com superfícies modificadas por feixe de laser com e sem deposição química de apatitas : análises topográfica, biomecânica e histométrica em coelhos /Queiroz, Thallita Pereira. January 2010 (has links)
Resumo: O sucesso da reabilitação com implantes osseointegráveis é dependente de vários fatores, destacando-se as propriedades físico-químicas da superfície, que interferem nas respostas biológicas e conseqüente reparo ósseo da interface osso/implante. O propósito deste estudo foi avaliar as superfícies de implantes de titânio comercialmente puro (Ticp) modificadas por feixe de laser (SL) sem e com deposição de hidroxiapatita pelo método biomimético, sem (SHAST) e com tratamento térmico (SHACT), comparando-as com implantes de superfície modificada por tratamento ácido (SA) e com superfície usinada (SU), empregando-se análises topográfica, biomecânica e histométrica. Quarenta e cinco coelhos receberam 150 implantes, sendo 2 implantes de cada superfície por tíbia. Após 30, 60 e 90 dias, os animais foram submetidos à eutanásia e os implantes localizados superiormente foram expostos, removidos por torque-reverso para análise biomecânica e as superfícies foram analisadas topograficamente. O implante localizado mais inferiormente em cada tíbia foi removido com o tecido ósseo ao redor e processado para obtenção de cortes histológicos não-descalcificados para análise histométrica da extensão linear de contato osso/implante (ELCOI) e da área óssea (AO) entre as espiras da região cortical superior. Aos 30 e 60 dias, os grupos SL, SHAST, SHACT e SA apresentaram valores de torque-reverso estatisticamente superiores (p<0,05) ao torque de SU. Aos 30 dias, os grupos SHAST e SHACT foram estatisticamente superiores ao grupo SA e o grupo SHAST foi superior ao SL. Aos 90 dias a diferença foi observada somente entre SHAST e SU. A análise topográfica revelou diferença estatística significante (p<0,05) entre a rugosidade de SL, SHAST e SHABT quando comparadas com SA e SU. A análise histométrica da ELCOI mostrou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The success of rehabilitation with dental implants is dependent on several factors, highlighting the physical and chemical properties of the implant surface, which interfere with the biological responses and subsequent bone repair of bone-implant interface. The purpose of this study was to evaluate the surfaces of implants of commercially pure titanium (cp Ti) modified by laser beam (LS) with and without hydroxyapatite deposition by the biomimetic method, without (HAB) and with thermal treatment (HABT) comparing them with implants surface modified by treatment with acid (AS) and machined surface (MS), employing topographical, biomechanics and histometric analysis. Forty-five rabbits received 150 implants (2 implants of each surface in each tibia). After 30, 60 and 90 days, the animals were euthanized and the implants superiorly located were exposed, removed by removal torque for biomechanical analysis and the surfaces were examined topographically. The implant located more inferiorly in each tibia was removed with the bone tissue around and it was processed to obtain non-decalcified histological sections for histometric analysis of the percentage of bone-implant contact (BIC) and bone area (BA) between the threads of higher cortical. At 30 and 60 days, the groups LS, HAB, HABT and AS obtained removal torque values statistically superior (p <0.05) than the removal torque of MS. At 30 days, the HAB and HABT groups were statistically superior to the AS group and HAB was higher than LS. At 90 days, HAB was statistically significant different from MS. The topographical analysis showed statistically significant difference (p <0.05) between the roughness of LS, HAB and HABT when compared with AS and MS. The histometric analysis of BIC showed that LS, HAB and HABT were statistically superior to the AS and MS, in three... (Complete abstract click electronic access below) / Orientador: Eduardo Hochuli Vieira / Coorientador: Antônio Carlos Guastaldi / Coorientador: Roberta Okamoto / Banca: Cássio Edvard Sverzut / Banca: Idelmo Rangel Garcia Júnior / Banca: Elcio Marcantonio Junior / Banca: Wilson Roberto Poi / Doutor
|
Page generated in 0.0808 seconds