1

Advanced surge protection devices

Wilson, Robin January 1992 (has links)
No description available.
2

Överspänningsskydd / Surge Protection

Hilleberg, Jesper, Falakeh, Sam January 2021 (has links)
Solar Bora is a company that works to bring electricity to small villages in Africa to help them save time in cooking and other things that we nowadays forget about. Africa is the continent with the most thunder strikes in the entire world, and it is therefore common that electronics get affected by this. Our work helps to protect against the surges caused by the electromagnetic pulses that are made by nearby thunder strikes. A surge protection is made using two surge protection devices, a metal oxide varistor and a transient voltage suppression diode in parallel. These are made to short-circuit large transients to ground to protect a circuit from the damaging transient. To test the circuit, we charged a capacitor up to 720 volts and then short-circuited it against the protective circuit to create a high voltage transient. The protective circuit managed to protect against the created transient, but a larger transient would be preferable to see the circuit’s full potential. / Solar Bora är ett företag som jobbar med att skapa energi till de små byar i Afrika som inte har tillgång till det, för att hjälpa dem spara tid vid matlagning och andra vardagssysslor som vi tar för givet. Afrika är den kontinent som har mest åsknedslag i hela världen och det är därför vanligt att elektronik skadas utav åsknedslagen. Arbetet som utförs kommer hjälpa skydda den elektroniken tillhörande Solar Boras system mot överspänningar orsakade av de elektromagnetiska pulserna från närliggande åsknedslag. Ett överspänningsskydd skapas genom användningen av en metal oxide varistor och en transient voltage suppression diode parallellkopplat. Dessa kortsluter stora transienter till jord för att skydda kretsen mot den skadande transienten. För att testa kretsen användes en uppladdad kondensator på 720V som sedan kortslöts mot kretsen för att skapa en högspänningstransient. Skyddet lyckades att dämpa transienten som tänkt men större transienter skulle behövts för att visa kretsens fulla potential.
3

Coordenação de dispositivos de proteção contra surtos em baixa tensão: ênfase instalações nucleares. / Low-voltage surge pretective device coordination: emphasis nuclear facilities.

Borsoi, Sad Sandrini 15 December 2017 (has links)
O trabalho apresenta uma metodologia aplicável à coordenação de dispositivos de proteção contra surtos em sistemas de corrente alternada de baixa tensão. Esta tem como base a adequação dos níveis de isolamento e imunidade dos equipamentos elétricos e eletrônicos e de energia absorvida pelos dispositivos de proteção. A principal motivação está relacionada aos critérios de segurança e confiabilidade requeridos por instalações nucleares, em que a coordenação da proteção contra surtos assume um importante papel. Uma metodologia interativa é implementada visando otimizar o processo de análise e especificação dos dispositivos de proteção, considerando a adoção de métodos analíticos e numéricos. Modelos de equipamentos elétricos e eletrônicos, quando submetidos a surtos de tensão e corrente, além dos dispositivos de proteção contra surtos, são implementados no simulador de transitórios eletromagnéticos - ATP. Destacam-se nestes estudos, as análises de configurações e arranjos do sistema elétrico, assim como seus parâmetros, a influência destes na configuração ou arranjo ótimo dos dispositivos de proteção, além do atendimento aos requisitos das normas aplicáveis. / The work presents a methodology regarding to low-voltage surge protective device coordination. This is based on adequacy of the isolation and immunity level of electrical and electronic equipment and the energy absorbed by the protective devices. The main motivation is related to the required nuclear plant reliability and safety criteria, in whose the surge protection coordination can assume an important role. An interactive methodology is carried out to optimize the analysis and the protection device specification, considering the adoption of analytical and numerical methods. Electrical and electronic equipment models, when submitted to voltage and current surges, in addition to surge protective devices, are implemented in the electromagnetic transient simulator - ATP. In these studies, the analysis of electrical system configurations and arrangements, as well as their parameters, and their influence on the configuration or optimum protective device arrangement, besides compliance with the requirements of applicable standards are highlighted.
4

Coordenação de dispositivos de proteção contra surtos em baixa tensão: ênfase instalações nucleares. / Low-voltage surge pretective device coordination: emphasis nuclear facilities.

Sad Sandrini Borsoi 15 December 2017 (has links)
O trabalho apresenta uma metodologia aplicável à coordenação de dispositivos de proteção contra surtos em sistemas de corrente alternada de baixa tensão. Esta tem como base a adequação dos níveis de isolamento e imunidade dos equipamentos elétricos e eletrônicos e de energia absorvida pelos dispositivos de proteção. A principal motivação está relacionada aos critérios de segurança e confiabilidade requeridos por instalações nucleares, em que a coordenação da proteção contra surtos assume um importante papel. Uma metodologia interativa é implementada visando otimizar o processo de análise e especificação dos dispositivos de proteção, considerando a adoção de métodos analíticos e numéricos. Modelos de equipamentos elétricos e eletrônicos, quando submetidos a surtos de tensão e corrente, além dos dispositivos de proteção contra surtos, são implementados no simulador de transitórios eletromagnéticos - ATP. Destacam-se nestes estudos, as análises de configurações e arranjos do sistema elétrico, assim como seus parâmetros, a influência destes na configuração ou arranjo ótimo dos dispositivos de proteção, além do atendimento aos requisitos das normas aplicáveis. / The work presents a methodology regarding to low-voltage surge protective device coordination. This is based on adequacy of the isolation and immunity level of electrical and electronic equipment and the energy absorbed by the protective devices. The main motivation is related to the required nuclear plant reliability and safety criteria, in whose the surge protection coordination can assume an important role. An interactive methodology is carried out to optimize the analysis and the protection device specification, considering the adoption of analytical and numerical methods. Electrical and electronic equipment models, when submitted to voltage and current surges, in addition to surge protective devices, are implemented in the electromagnetic transient simulator - ATP. In these studies, the analysis of electrical system configurations and arrangements, as well as their parameters, and their influence on the configuration or optimum protective device arrangement, besides compliance with the requirements of applicable standards are highlighted.
5

Zvýšení úrovně spolehlivosti dodávky elektrické energie z hydrocentrály Jasenie do Železiarní Podbrezová / Increasing of reliability of power supply from the Jasenie hydropower plant to Železiarně Podbrezová

Budovec, Michal January 2019 (has links)
This thesis deals with operation of the Jasenie hydroelectric power plant, which supplies electricity to Železiarne Podbrezová Inc. This thesis describes actual operation, devices and equipment in all substations. The second chapter briefly describes company’s history and activities of the company. The next chapter mentions an overview of the sources of own electricity production. The fourth chapter in detail deals with actual situation of the hydroelectric power plant operation, describes devices and equipment in all substations. It also outlines what measures should be taken to increase the reliability of electricity supply. Next part deals with replacing insulators on the 22 kV line. Sixth chapter is focused on protection this line by multifunctional protection relay and data transfer from HC Jasenie to the building of power engineering. In the next step is designed a backup transformer with bus control for thermal and dynamic effects of the short-circuit current. The last chapter is focused on surge protection in HC Jasenie as well as in the area of Stary závod substation. The results and benefits of this work are summarized in the conclusion. The attachment contains schemes of substations and overall overview scheme, which are used for better understanding of this problem.
6

Estudo de surtos em redes secundárias de distribuição devido a descargas atmosféricas diretas na rede primária. / Surge study on secondary distribution networks due to direct lightning discharges in the primary networks.

Bassi, Welson 09 December 1999 (has links)
Este trabalho apresenta uma análise dos surtos em redes aéreas secundárias de distribuição causados por descargas atmosféricas diretas no circuito primário. Alguns trabalhos publicados sobre o fenômeno são comentados, sendo também analisados vários outros estudos relativos à modelagem de componentes. No trabalho, os principais componentes da rede foram modelados e incluídos na representação de uma topologia típica (com as linhas primária e secundária). Assim, foram considerados: transformador de distribuição, isoladores, pára-raios, cargas (consumidores) e resistências de aterramento. Os modelos foram validados, quando possível, através de ensaios em laboratório. Algumas alternativas de proteção da rede secundária foram consideradas. Foi verificada a influência de alguns parâmetros relevantes tais como amplitude e tempo de frente da corrente da descarga, resistências de aterramento, modelos de cargas e posição da descarga. Os resultados foram obtidos por simulações computacionais realizadas através do programa ATP (Alternative Transients Program). São apresentadas formas de onda de sobretensões nos consumidores. Também são apresentados e discutidos valores de corrente e energia nos dispositivos de proteção, fornecendo informações sobre as alternativas de proteção. / This work presents an evaluation of surges in low-voltage overhead distribution lines caused by direct lightning strikes in medium voltage lines. Some publications concerning the phenomenon are commented and several other studies used during the process of modeling of the components are also analysed. The main components of the distribution system were modeled and included. So, a typical distribution network topology (with the primary and secondary lines) was represented including its components: distribution transformer, insulators, surge arresters, loads and ground resistances. The performance of the developed models, whenever possible, was verified by laboratory tests. Some possibilities of the secondary protection were included. Parameters having major effect on the results, such as the lightning current amplitude and front time, the values of grounding resistances, the models of the loads and the lightning strike position were taken into consideration in the study. The results were obtained by simulations performed using the ATP (Alternative Transients Program). Waveforms are presented in order to provide information on the characteristics of the overvoltages in the consumers along the line. Currents, as well as energy absorbed by the low-voltage surge arresters are aldo presented and discussed, providing useful information about the performance of some protection alternatives.
7

Caracterização de equipamentos e instalações residenciais de baixa tensão aplicada ao estudo de transitórios de origem atmosférica. / Low voltage residential equipment and installations modelling applied to the study of lightning transients.

Bassi, Welson 25 August 2005 (has links)
Este trabalho apresenta um estudo de caracterização das impedâncias de entrada, em função da frequência, de instalações residenciais de baixa tensão e diversos equipamentos eletro-eletrônicos comumente encontrados. As respostas em frequência medidas são ajustadas e modeladas por redes RLC simples, mas efetivas, que podem ser utilizadas em qualquer programa computacional para simulações de transitórios. A faixa de frequências, até 5 MHz, permite o uso desses modelos em estudos associados a transitórios atmosféricos ou causados por chaveamentos. É importante ressaltar a existência de muito poucos trabalhos nesse assunto, pois, usualmente, as instalações de baixa tensão, ou os equipamentos conectados, são representadas por simples elementos concentrados, resistores, indutores ou capacitores. Por outro lado, sabe-se que os níveis de sobretensões em um sistema, ou instalação, são fortemente dependentes das cargas conectadas e, quanto mais precisos os modelos, melhores e mais confiáveis simulações são obtidas. Este trabalho inclui simulações com o programa computacional ATP utilizando os modelos desenvolvidos para avaliação de surtos em uma rede de distribuição típica submetida a descargas atmosféricas diretas no circuito primário. Além disso, utilizando o programa Pspice, são realizadas simulações da resposta interna de uma instalação residencial, com diversos equipamentos conectados, e submetida a surtos atmosféricos em sua entrada. O trabalho concentra informações práticas e úteis sobre estudos de surtos em sistemas e instalações de baixa tensão / This work presents a study of impedance characteristics, over a wide range of frequencies, of residential low-voltage installations and electric-electronic appliances, commonly found in residential installations. The measured frequency responses are fitted and modeled by simple, but effective, RLC networks, that can be used in any software for transient simulations. The range of frequencies, up to 5 MHz, allows the use of these models considering lightning or switching studies. It is of importance to point the lack of publications focusing this topic, because usually the low-voltage installations, or connected equipment, are represented by simple lumped components inductances, resistances or capacitances. Otherwise, it is well known that the overvoltage level of a system, or installation, is strongly dependent on the connected loads and for more precise models, better and more reliable simulation results are obtained. This work includes ATP software simulations using the developed models for evaluation of surges in a typical distribution network subjected to direct lightning strikes at the primary circuit. Furthermore, simulations of internal response of a low-voltage installation with connected equipment and subjected to lightning surges in its entrance is performed using the Pspice software. The work summarizes practical and useful information about the low-voltage surge studies on low-voltage systems.
8

Estudo de surtos em redes secundárias de distribuição devido a descargas atmosféricas diretas na rede primária. / Surge study on secondary distribution networks due to direct lightning discharges in the primary networks.

Welson Bassi 09 December 1999 (has links)
Este trabalho apresenta uma análise dos surtos em redes aéreas secundárias de distribuição causados por descargas atmosféricas diretas no circuito primário. Alguns trabalhos publicados sobre o fenômeno são comentados, sendo também analisados vários outros estudos relativos à modelagem de componentes. No trabalho, os principais componentes da rede foram modelados e incluídos na representação de uma topologia típica (com as linhas primária e secundária). Assim, foram considerados: transformador de distribuição, isoladores, pára-raios, cargas (consumidores) e resistências de aterramento. Os modelos foram validados, quando possível, através de ensaios em laboratório. Algumas alternativas de proteção da rede secundária foram consideradas. Foi verificada a influência de alguns parâmetros relevantes tais como amplitude e tempo de frente da corrente da descarga, resistências de aterramento, modelos de cargas e posição da descarga. Os resultados foram obtidos por simulações computacionais realizadas através do programa ATP (Alternative Transients Program). São apresentadas formas de onda de sobretensões nos consumidores. Também são apresentados e discutidos valores de corrente e energia nos dispositivos de proteção, fornecendo informações sobre as alternativas de proteção. / This work presents an evaluation of surges in low-voltage overhead distribution lines caused by direct lightning strikes in medium voltage lines. Some publications concerning the phenomenon are commented and several other studies used during the process of modeling of the components are also analysed. The main components of the distribution system were modeled and included. So, a typical distribution network topology (with the primary and secondary lines) was represented including its components: distribution transformer, insulators, surge arresters, loads and ground resistances. The performance of the developed models, whenever possible, was verified by laboratory tests. Some possibilities of the secondary protection were included. Parameters having major effect on the results, such as the lightning current amplitude and front time, the values of grounding resistances, the models of the loads and the lightning strike position were taken into consideration in the study. The results were obtained by simulations performed using the ATP (Alternative Transients Program). Waveforms are presented in order to provide information on the characteristics of the overvoltages in the consumers along the line. Currents, as well as energy absorbed by the low-voltage surge arresters are aldo presented and discussed, providing useful information about the performance of some protection alternatives.
9

Caracterização de equipamentos e instalações residenciais de baixa tensão aplicada ao estudo de transitórios de origem atmosférica. / Low voltage residential equipment and installations modelling applied to the study of lightning transients.

Welson Bassi 25 August 2005 (has links)
Este trabalho apresenta um estudo de caracterização das impedâncias de entrada, em função da frequência, de instalações residenciais de baixa tensão e diversos equipamentos eletro-eletrônicos comumente encontrados. As respostas em frequência medidas são ajustadas e modeladas por redes RLC simples, mas efetivas, que podem ser utilizadas em qualquer programa computacional para simulações de transitórios. A faixa de frequências, até 5 MHz, permite o uso desses modelos em estudos associados a transitórios atmosféricos ou causados por chaveamentos. É importante ressaltar a existência de muito poucos trabalhos nesse assunto, pois, usualmente, as instalações de baixa tensão, ou os equipamentos conectados, são representadas por simples elementos concentrados, resistores, indutores ou capacitores. Por outro lado, sabe-se que os níveis de sobretensões em um sistema, ou instalação, são fortemente dependentes das cargas conectadas e, quanto mais precisos os modelos, melhores e mais confiáveis simulações são obtidas. Este trabalho inclui simulações com o programa computacional ATP utilizando os modelos desenvolvidos para avaliação de surtos em uma rede de distribuição típica submetida a descargas atmosféricas diretas no circuito primário. Além disso, utilizando o programa Pspice, são realizadas simulações da resposta interna de uma instalação residencial, com diversos equipamentos conectados, e submetida a surtos atmosféricos em sua entrada. O trabalho concentra informações práticas e úteis sobre estudos de surtos em sistemas e instalações de baixa tensão / This work presents a study of impedance characteristics, over a wide range of frequencies, of residential low-voltage installations and electric-electronic appliances, commonly found in residential installations. The measured frequency responses are fitted and modeled by simple, but effective, RLC networks, that can be used in any software for transient simulations. The range of frequencies, up to 5 MHz, allows the use of these models considering lightning or switching studies. It is of importance to point the lack of publications focusing this topic, because usually the low-voltage installations, or connected equipment, are represented by simple lumped components inductances, resistances or capacitances. Otherwise, it is well known that the overvoltage level of a system, or installation, is strongly dependent on the connected loads and for more precise models, better and more reliable simulation results are obtained. This work includes ATP software simulations using the developed models for evaluation of surges in a typical distribution network subjected to direct lightning strikes at the primary circuit. Furthermore, simulations of internal response of a low-voltage installation with connected equipment and subjected to lightning surges in its entrance is performed using the Pspice software. The work summarizes practical and useful information about the low-voltage surge studies on low-voltage systems.
10

Návrh přepěťové ochrany pro objekt s nebezpečím výbuchu / Design of overvoltage protection for the object with explosive risk

Polášek, Roman January 2014 (has links)
This master´s thesis deals with the designing process of surge protection for the object potentially explosive atmospheres and according to a set of standards ČEN EN 62305 and ČSN EN 60079. This work consists of four main parts. The first part deals with the theory of lightning and surges. Subsequently, in the second part is devoted to the theory of protection against these phenomena and proposals for external and internal lightning protection and surge. This chapter also deals with more demands on electrical installations in hazardous areas. The third part deals with the analysis of the risks to the subject paint and according to ČSN EN 62305-2 ed.2 and at the conclusion of the study is a proposal for external lightning protection and internal surge protection.