• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 25
  • 25
  • 12
  • 12
  • 10
  • 10
  • 8
  • 7
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Impacto de orificios padronizados na integração de telas de polipropileno na parede abdominal de ratas : analise estereologica e da retração do material / The impact of standarized orifices on the integration and retraction of polypropylene meshes in abdominal wall of rats : in vivo stereologycal analyses

Cardia, Fishiler Pimentel Zitenfeld 12 August 2018 (has links)
Orientadores: Rogerio de Fraga, Paulo Cesar Rodrigues Palma / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T22:24:52Z (GMT). No. of bitstreams: 1 Cardia_FishilerPimentelZitenfeld_M.pdf: 1370656 bytes, checksum: 9c1061423f4725bab06c637f1e6c0958 (MD5) Previous issue date: 2009 / Resumo: A crescente utilização de telas de polipropileno em cirurgia pélvica reconstrutiva levou ao aparecimento de complicações inerentes ao uso dos materiais sintéticos, tais como retração, exposição e infecção. Com o objetivo de avaliar a retração de telas de polipropileno de media gramatura e melhorar a incorporação da mesma através de orifícios de 5 mm de diâmetro, realizamos um estudo experimental "in vivo". Método: No presente estudo, avalia a morfologia e a densidade volumétrica das fibras de colágeno em malhas com e sem orifícios padronizados, bem como; a retração das mesmas, por meio de mensuração radiográfica e direta da tela. A amostra consistiu de 14 ratas fêmeas da raça Wistar, que foram sacrificadas 90 dias após o implante. O abdômen foi ressecado e radiografado antes de ser preparado o estudo histológico e estereológico. A distribuição do colágeno foi avaliada por estereologia nos três compartimentos: pele, fascia de Colles e na região do implante da Tela entre a fascia de Colles e a aponeurose dos músculos retos abdominais. Resultados: Não houve retração das telas de polipropileno nas aferições radiográficas e medidas diretas. A estereologia evidenciou deposição de fibras de colágenos organizadas nos orifícios. Ao contrário nas telas sem orifícios, a deposição de colágeno foi maior e desorganizada, com cistos de inclusão. Outro dado relevante foi que a estrutura das fibras de colágeno apresentou-se morfologicamente normal nos animais de tela com orifício, e houve uma maior proximidade entre a pele e a musculatura no local do orifício. Conclusões: A análise histológica revelou menor reação inflamatória nas telas com macro orifícios. A avaliação estereológica da densidade volumétrica das fibras de colágeno nas telas com e sem orifícios, permitiu observar que os macro orifícios agiram como fator facilitador da integração do enxerto e que poderá representar implicações na parte clinica médica. Palavras chaves: Polipropileno; Telas cirúrgicas / Abstract: The meshes in reconstructive pelvic surgery have led to complications inherent to the use of synthetic materials, such as retraction, exposure and infection. In order to improve mesh integration we created standardized orifices, 5 mm in diameter of monofilament polypropylene mesh and compared local tissue reaction with regular meshes in an animal study. Method: We evaluated the morphology and volumetric density of collagen fibers in meshes with and without standardized orifices, as well as its retraction through radiographic and direct measurement of the meshes. The sample consisted of 15 female Wistar rats, which were sacrificed 90 days after the implant. The abdominal wall was removed and x-ray was taked before its preparation for histological and stereological study (estimate the density of an element of a homogeneous area). The volumetric density of the collagen fibers was calculated by stereological tool in three compartments: skin, Colles' fascia and mesh, the latter located between the Colles' fascia and the aponeurosis of the rectus abdominalis muscles. Results: There was no retraction of the polypropylene meshes. The histological and stereological analysis disclosed organized collagen fiber deposition in the orifices and less inflammatory reaction than the control meshes with no orifices. Conclusions: There was no mesh retraction in both groups. The histological and stereological results suggest that the standardized orifices facilitated tissue integration and may have clinical application. Keywords: Polypropylene; Surgical meshes / Mestrado / Cirurgia / Mestre em Cirurgia
2

Efeitos biomecânicos e histológicos do recobrimento de tela de polipropileno com gel purificado de colágeno : estudo experimental / Biomechanical and histologic effects of coating a polypropylene mesh with a purified collagen gel : experimental study

Siniscalchi, Rodrigo Teixeira, 1971- 21 August 2018 (has links)
Orientadores: Cássio Luís Zanettini Riccetto, Benedicto de Campos Vidal / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-21T17:40:56Z (GMT). No. of bitstreams: 1 Siniscalchi_RodrigoTeixeira_D.pdf: 4712721 bytes, checksum: 84737665d5451453e82931eab2e748c4 (MD5) Previous issue date: 2012 / Resumo: Introdução: O material sintético (tela) mais utilizado atualmente no tratamento da Incontinência Urinária de Esforço (IUE) e dos prolapsos da parede vaginal, também conhecidos como Prolapsos dos Orgãos Pélvicos (POP) é o polipropileno monofilamentar, com índices de cura de até 90%. Porém, as complicações relacionadas à integração tecidual desses implantes são relativamente prevalentes. O colágeno, por ser um material biologicamente compatível, pouco imunogênico e com propriedades moduladoras do processo inflamatório, pode ser utilizado como um importante agente cicatrizante e, nesse sentido, poderia melhorar a integração das telas. Objetivo: Estudar os efeitos biomecânicos e histológicos do recobrimento de tela de polipropileno monofilamentar com gel purificado de colágeno, implantadas no tecido subcutâneo de ratas. Material e Métodos: Vinte ratas foram utilizadas para o estudo histológico e outras 20 para o estudo biomecânico. De um lado da parede abdominal do animal foi implantado um fragmento tela de polipropileno monofilamentar macroporosa medindo 20 x 10 mm, habitualmente utilizada no tratamento da IUE e dos POP (Grupo I), denominada PLP (tela de polipropileno) e do outro lado foi implantada uma tela com as mesmas dimensões recoberta com gel purificado de colágeno (Grupo II), denominada PLP+C (tela de polipropileno recoberta com o gel purificado de colágeno). De acordo com o tempo de eutanásia (7, 30, 90 ou 180 dias) após o implante os animais de cada grupo foram divididos em quatro subgrupos contendo cinco animais cada. Foi então realizada excisão em bloco da parede abdominal para as análises. O estudo biomecânico foi realizado em um tensiômetro de precisão, no qual a tela era tracionada em sentido uniaxial até que se desprendesse da interface tecidual. Para quantificar a aderência do material, em cada grupo, foi analisada a carga máxima necessária para este desprendimento. No estudo histológico foram analisadas as características relativas à inflamação aguda e crônica além do tecido de granulação, formação de granuloma e reação de corpo estranho em lâminas coradas com Hematoxilina-Eosina (HE), utilizando-se de método semiquantitativo. A organização supramolecular da deposição colágena em torno das telas foi estudada através de microscopia de polarização (birrefringência). Resultados: No estudo biomecânico observou-se que a aderência das telas de polipropileno aos tecidos circunvizinhos aumentou significativamente após o recobrimento com o gel purificado de colágeno, como demonstrado na análise dos valores encontrados para a Carga Máxima no 7º (p=0,0016), 14º (p=0,0039), 90º (p=0,0009) e 180º (p=0,0029) dias após o implante. Considerou-se nessa pesquisa, que o aumento da biocompatibilidade da tela de polipropileno seria alcançado quando, na interface tecidual, houvesse redução da intensidade do processo inflamatório. Verificou-se que a resposta inflamatória crônica e aguda (neutrofílica), assim como a formação de tecido de granulação foi menos intensa, respectivamente p=0,004, p<0,001 e p=0,001 nas telas recobertas com o colágeno na fase inicial (7º e 14º dias) e ausente, assim como nas telas não recobertas na fase tardia (90º e 180º dias). A inflamação granulomatosa foi observada de forma menos significativa aos sete dias após o implante nos animais do grupo II (p=0,029) e em ambos os grupos, de maneira similar, diminuiu ao longo do tempo não mostrando diferença significativa. A reação de corpo estranho foi menos intensa na fase inicial no grupo II (p<0,001) e semelhante entre os grupos na fase tardia. Nas análises de birrefringência foi observado no período inicial (sete dias) uma maior densidade média de brilho (transmitância) a favor das telas não recobertas (p=0,000), porém nos outros períodos analisados a densidade média de brilho foi maior nas tela do grupo II (PLP+C), 14 dias (p=0,000), 90 dias (p=0,000) e em 180 dias (p=0,000). Conclusão: O recobrimento das telas de polipropileno com o gel purificado de colágeno aumentou sua aderência aos tecidos, quando implantadas na interface da parede abdominal de ratas adultas, tanto precocemente quanto tardiamente; promoveu uma resposta inflamatória menos intensa e duradoura e na fase tardia do implante desencadeou maior organização e empacotamento das fibras de colágeno. Estes dados inferem que a tela recoberta com o gel purificado de colágeno quando locada em seu leito de implante terá, provavelmente, menor mobilidade e também uma melhor adaptação e integração ao corpo do hospedeiro resultando em menor chance de complicações / Abstract: Introduction: The synthetic material most currently used in the treatment of stress urinary incontinence (SUI) and vaginal wall prolapse, also known as pelvic organ prolapse (POP) is the monofilament polypropylene mesh (PLP). However, complications related to tissue integration of these implants are relatively prevalent. Collagen is the main structural protein of mammals, which modulates inflammatory process, and can be used as an important healing agent and, accordingly, could improve the integration of the meshes. Objetives: To study the biomechanical and histological effects of PLP, coated with purified collagen gel, implanted in the subcutaneous tissue of adult rats. Methods: Twenty rats were used for histological study and other 20 for the biomechanical study. At one side of the abdominal wall, PLP fragment measuring 20x10 mm was implanted (Group I), and in the other side a mesh fragment with the same dimensions coated with purified collagen gel PLP+C) was implanted (Group II). According to the time of euthanasia (7, 30, 90 or 180 days) after implantation the animals from each group were divided into four subgroups of five animals each. The biomechanical study was performed with a precision tension meter with in bloc fresh abdominal wall sample containing the mesh. The mesh was pulled up in uniaxial direction until complete detachment of the tissue interface and the maximum load required for the detachment was analyzed in each group. In the histological study, it was examined characteristics of the acute and chronic inflammatory reaction, granulation tissue, granuloma formation, and foreign body reaction on slides stained with hematoxylin-eosin. The supramolecular organization of the collagen deposition around the meshes was studied with polarizing microscopy (birefringence analysis). Results: In biomechanical study it was observed that the adhesion of PLP to surrounding tissues increased significantly after coating with purified collagen gel, as shown in the analysis of the maximum load at the 7th (p=0.0016), 14th (p=0.0039), 90th (p=0.0009) and 180th (p=0.0029) days after implantation. It was considered in this research, that increased biocompatibility of PLP would be achieved when, in tissue interface, there was a reduction of the intensity of the inflammatory process. It was found that the acute and chronic inflammatory response, as well as the formation of granulation tissue were less intense, respectively p=0.004, p<0.001 and p=0.001 for PLP+C in the initial phase (7th and 14th days) and missing, as well as on the meshes not covered in late phase (90th and 180th days). Granulomatous inflammation was less significant seven days after implantation in animals of Group II (p=0.029) and in both groups, similarly, decreased over time showing no significant difference. The foreign body reaction was less intense in the initial phase in Group II (p<0.001) and similar between the groups in the late phase. In the birefringence analyses, it was noted a greater average density of brightness (transmittance) in PLP (p=0.000) in the initial period (seven days), but in other periods it was greater for PLP+C [14 days (p=0.000); 90 days (p=0.000) and 180 days (p=0.000)]. Conclusions: Coating of polypropylene meshes with purified collagen gel increased their adhesion to the tissues, when implanted in the subcutaneous of the abdominal wall of adult rats and promoted a less intense and lasting inflammatory response and, in the late stage of the implant, triggered greater organization and packaging of collagen fibers. Based on that, one can suppose that mesh coated with purified collagen gel can fix better to the host tissues preventing its displacing, and can elicit fewer integration defects, resulting in less chance of complications / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências
3

The efficacy of biodegradable mesh as a fixation device for support of autogenous onlay bone grafts : a radiographic and histomorphometric analysis

Al-Jandan, Badr. January 2007 (has links)
Objective. The objective of this study is to test the efficacy of the biodegradable mesh as an alternative fixation device to the titanium mesh for support of onlay particulate, bone and cancellous, marrow (PBCM) grafts. Two parameters were evaluated: (1) Bone graft volume maintenance; and (2) Calcified tissue surface area and distribution. Methods. 12 New Zealand white rabbits were used and divided equally into two groups. In both groups, endochondral, cancellous bone graft was harvested from the anterior ilium. The bone graft was then compressed and placed as an onlay onto the lateral aspect of the mandible using two chambers for each animal. In the control group, the chambers were made of titanium, however in the test group the chambers were made of poly L-lactide, polyglycolide and trimethylene carbonate mesh (Inion GTR(TM) Finland), and thereafter the chambers were fixed to the mandible. The animals were then sacrificed after eight weeks postoperatively, and then Micro-CT imaging was performed for the entire sample in order to determine the total volume of calcified tissue present under each chamber. In addition, Histologic sections were obtained from each chamber, and thereafter stained using Toluidine blue and Von Kossa for the purpose of histomorphometric analysis in order to determine the calcified tissue surface area. Results. When comparing the data from both the titanium (Ti) and the biodegradable mesh (PLA) groups, Micro CT analysis showed no significant statistical difference (P-value = 0.546) with regard to the percentage of bone found under the chambers (Ti 15.0% and PLA 13.83%). Interestingly, neither did the histomorphometric analysis show any significant statistical deference (P-value = 0.8272) with regard to the percentage of calcified tissue surface area (Ti 16.86% and PLA 16.17%). Moreover, this calcified tissue was also found to be evenly distributed in both groups. Conclusion. Biodegradable mesh made of poly L-lactic and polyglycolic acid copolymers appears to be an appropriate alternative to the Ti mesh for support of PBCM bone grafts. However, further clinical trails should be conducted to confirm these findings.
4

Efeitos biomecanicos da inclusão de orificios de tamanho padronizado em telas de polipropileno monofilamentar na interface tecidual da parede abdominal de ratas adultas / Biomechanical effects of the inclusion of the standardized orifices in monofilament polypropylene meshes at abdominal wall interface of adult female rats

Siniscalchi, Rodrigo Teixeira, 1971- 11 November 2008 (has links)
Orientadores: Cassio Luis Zanettini Riccetto, Paulo Cesar Rodrigues Palma / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T04:47:27Z (GMT). No. of bitstreams: 1 Siniscalchi_RodrigoTeixeira_M.pdf: 4843609 bytes, checksum: 15b98ee38e8ef7b8b7e68b7ace186491 (MD5) Previous issue date: 2008 / Resumo: Introdução: Os prolapsos da parede vaginal são muito prevalentes. Em seu tratamento utilizam-se técnicas baseadas em suturas (correções sítio-específicas) ou, mais recentemente, o emprego de telas (próteses). Considerando-se a elevada taxa de recorrência com as técnicas convencionais, as telas passaram a representar uma opção potencial para o tratamento de casos selecionados de prolapsos urogenitais. O material sintético mais utilizado atualmente é o polipropileno monofilamentar, com índices de cura de até 90%. Com o objetivo de diminuir a quantidade de material implantado e promover melhor integração da prótese aos tecidos, evitando, respectivamente, a dispareunia e a extrusão das mesmas, foi proposta a inclusão de orifícios de tamanho padronizado nas telas, denominados orifícios facilitadores de integração. Objetivo: Avaliar, "in vivo", as propriedades biomecânicas de um tipo tela de polipropileno monofilamentar e os efeitos da inclusão de orifícios facilitadores de integração sobre a resistência na interface com o leito receptor. Material e Métodos: Foram utilizadas 40 ratas adultas nas quais foram implantadas, de um lado da sua parede abdominal, na interface entre a hipoderme e a fáscia anterior da musculatura abdominal, uma tela de polipropileno monofilamentar retangular medindo 24 x 11 mm sem orifícios (grupo 1) e, do outro lado uma tela semelhante, com 2 orifícios circulares de 6mm de diâmetro (grupo 2). Após 90 dias, as ratas foram sacrificadas sendo sua parede abdominal retirada e dividida simetricamente em 2 blocos, que continham, respectivamente, as telas com e sem orifícios. O estudo biomecânico foi realizado em um tensiômetro de precisão, no qual a tela era tracionada em sentido uniaxial até que se desprendesse da interface tecidual. Para quantificar a aderência e elasticidade tecidual, em cada grupo, foram analisadas as seguintes variáveis: carga máxima; deflexão até a carga máxima; trabalho até a carga máxima; consistência do material; além dos valores de carga, deflexão e trabalho executado no momento do desprendimento da tela. Resultados: Verificou-se que a aderência das telas de polipropileno aos tecidos circunvizinhos aumentou significativamente com a inclusão de orifícios de tamanho padronizado como demonstrado na análise dos valores encontrados para a carga máxima (p < 0,001); trabalho até a carga máxima (p < 0,001); carga no desprendimento da tela (p < 0,001); e trabalho até o desprendimento da tela (p < 0,001). Os orifícios também conferiram à tela de polipropileno maior elasticidade, como demonstrado na análise dos valores de deflexão até a carga máxima (p < 0,001) e deflexão até o desprendimento da tela (p < 0,001). Não foi observada diferença significante (p = 0,87) quando analisada a variável consistência do material (ou módulo de elasticidade). Conclusão: A inclusão de orifícios de tamanho padronizado em telas de polipropileno monofilamentar, além de reduzir o seu peso e a quantidade de material implantado, aumentou sua elasticidade e aderência aos tecidos quando implantadas na interface da parede abdominal de ratas adultas. Estes achados sugerem que a inclusão de orifícios facilitadores de integração pode influenciar, favoravelmente, o seu emprego na prática clínica. / Abstract: Objective: The use of polypropylene mesh to repair vaginal prolapse is well established in selected cases. In order to reduce the weight and increase the elasticity of the mesh, to bind the product to tissues and also to decrease the amount of material used, the inclusion of standard orifices to the size meshes was proposed. These orifices were called "helper orifices" as they improve integration. In this original study, the biomechanical properties of a type of monofilament polypropylene mesh were evaluated in vivo, as well as the effects of the inclusion of the orifices on the interface resistance in the receiving area. Method: Forty female rats received an implant of monofilament polypropylene mesh, measuring 24 x 11 mm with no orifices, on one side of the abdominal wall, at the interface between the hypoderm and the anterior fascia of the abdominal muscles (group 1). On the other side, a similar mesh with two circular orifices (6 mm diameter) was implanted (group 2). The rats were euthanized 90 days later and their abdominal walls were removed and divided into two blocks, one with the mesh without orifices and the other with the mesh with orifices. The biomechanical study used a precision tensiometer in which the mesh was uniaxially tensioned until it was loosened from the tissue interface. In order to determine the tissue adherence in each group, the following variables were analyzed: maximum load; deflection at maximum load; work to maximum load; stiffness as well as load, deflection and work at detachment of the mesh. Results: It was verified that the adherence of the polypropylene mesh to the surrounding tissue increased significantly with the inclusion of standard size orifices as it is demonstrated in the analysis of values found to the maximum load (p < 0.001); work to maximum load (p < 0.001); load at detachment of the mesh (p < 0.001); and work to detachment of the mesh (p < 0.001). The orifices also brought higher elasticity to the polypropylene mesh as demonstrated in the analysis of the values of deflection at maximum load (p < 0,001) and deflection at detachment of the mesh (p < 0.001). It was not observed statistical differences (p = 0.87) when analyzing the stiffness of the material. Conclusion: Besides reducing the weight and amount of material, the inclusion of standard size orifices in the monofilament polypropylene mesh increased the elasticity and adherence to the tissues when implanted in the interface of the abdominal wall in adult female rats. These findings suggest that the inclusion of helper orifices to improve integration may have a favorable influence in clinical practice. / Mestrado / Cirurgia / Mestre em Cirurgia
5

The efficacy of biodegradable mesh as a fixation device for support of autogenous onlay bone grafts : a radiographic and histomorphometric analysis

Al-Jandan, Badr January 2007 (has links)
No description available.
6

Minimally invasive hernia surgery /

Bringman, Sven, January 2003 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2003. / Härtill 4 uppsatser.
7

Groin hernia surgery : studies on anaesthesia and surgical technique /

Nordin, Pär January 2003 (has links) (PDF)
Diss. (sammanfattning) Linköping : Univ., 2003. / Härtill 5 uppsatser.
8

Modelo experimental para o estudo do comportamento optico da parede abdominal e sua interação com um material protetico por biospeckle : trabalho experimental em ratos / Optical behavior of the abdominal wall and its interaction with a synthetic material in the surgery of the incisional hernias: experimental study in rats

Nieri, Tamara Maria 29 August 2005 (has links)
Orientador: Marco Antonio de Oliveira Peres / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-07T03:24:04Z (GMT). No. of bitstreams: 1 Nieri_TamaraMaria_D.pdf: 4800971 bytes, checksum: 479a127e9ad76c6ea9d61025a1714615 (MD5) Previous issue date: 2005 / Resumo: Hérnia incisional, afecção que incide em 2 a 15% das laparotomias, é uma complicação cirúrgica que continuará acompanhando, como vem fazendo até hoje, as cirurgias abdominais. A utilização mais freqüente de próteses tem alcançado resultados mais significativos na cura desta afecção. Diversos estudos vêm sendo realizados com diferentes métodos de avaliação da biocompatibilidade dos materiais protéticos. Modelos experimentais permitem estudos detalhados destas interações, no campo da anatomia, da fisiologia, da bioquímica, da microbiologia e da mecânica. O presente trabalho apresentou a criação de um modelo animal, que se mostrou viável, para o estudo da atividade tecidual da parede abdominal em sua interação com um material protético, utilizando um dos fenômenos ópticos da luz coerente (Laser), o biospeckle. Foram analisados 50 ratos Wistar machos, divididos em quatro grupos: Grupo 1 com 10 animais não submetidos à cirurgia; Grupo 2 com 10 animais submetidos a cirurgia sem a colocação de tela; Grupo 3 com 20 animais submetidos a cirurgia com colocação de tela de polipropileno pré-peritonial; Grupo 4 (Sham) com 10 animais. Nenhum animal apresentou complicações pós-operatórias, sendo levados, no 20º PO, ao ensaio óptico, que consistiu no posicionamento do animal anestesiado, em decúbito dorsal horizontal, sobre uma mesa óptica, tendo um feixe de Laser iluminando um ponto da linha média da parede abdominal. Um sistema de aquisição de imagens (LSI), composto por uma câmera (Charge Coupled Device - CCD), um processador digital de imagens e um microcomputador, captaram e processaram as imagens gerando um padrão STS (Space Time Speckle); este padrão, processado por um software, gerou uma Matriz de Ocorrências Modificada (MOM). O mesmo software calculou, a partir da MOM, o Módulo de Dispersão, um valor absoluto sem unidade, que foi o parâmetro de comparação dos espécimes, após tratamento estatístico. A análise dos dados obtidos permitiu concluir que o modelo animal criado é viável e que não houve diferença significativa, nos quatro grupos estudados, da atividade tecidual da parede abdominal de ratos, com e sem a implantação cirúrgica de prótese de polipropileno, quando utilizado o biospeckle / Abstract: Incisional hernia is an affection that occurs on 2% to 15% of laparotomy procedures, being also considered a surgical complication which has been following abdominal surgical procedures. Prosthesis applications have been conquered satisfactory results in heeling such affection. The literature discloses many research work reports on biocompatibility evaluation of prosthetic materials. Experimental models allow detailed studies of theses interactions under the anatomy point of view, as well as under the physiology, biochemistry, microbiology and mechanics. This research work reports the generation of an animal model useful in supporting the abdominal tissue activity considering its interaction with a prosthetic material, by means of technique based on the biospeckle phenomena. This way, 50 Wistar male rats were divided into four groups: Group 1, composed of ten animals not submitted to surgery; group 2, composed of ten animals submitted to surgery without polypropylene mesh; group 3, composed of 20 animals submitted to surgery followed by the mesh placement; group 4, sham with ten animals. None of the animals presented post surgical complications being submitted to the optical tests at the 20th postoperative day. The analysis from the biospeckle tests indicated that no significative difference was observed on the abdominal wall tissue activity in the four groups considered, with and without polypropylene mesh prosthesis implantation / Doutorado / Cirurgia / Doutor em Cirurgia
9

Alterações histopatologicas do ducto deferente de ratos exposto a tela de polipropileno / Histopathological altrations of the vas deferents in rats exposed to polypropilene mesh

Maciel, Luiz Carlos 27 February 2007 (has links)
Orientadores: Sidney Glina, Paulo Cesar Rodrigues Palma / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-08T16:27:53Z (GMT). No. of bitstreams: 1 Maciel_LuizCarlos_M.pdf: 1549076 bytes, checksum: f3d6484f2a41fafdf24e583249442169 (MD5) Previous issue date: 2007 / Resumo: Introdução: As operações para correção das hérnias inguinais podem ocasionar lesões nos ductos deferentes levando à infertilidade, sendo que a incidência destas lesões varia de 6,65% a 26,7%. As telas de polipropileno têm sido utilizadas em indivíduos jovens nas últimas décadas. Este material induz processo inflamatório e fibrose adjacente conferindo maior reforço à parede posterior do canal inguinal, entretanto não se conhece claramente a repercussão desta reação sobre a histologia e fisiologia do ducto deferente. Objetivo: Este estudo avaliou o comprometimento ou não do ducto deferente de ratos expostos à tela de polipropileno. Método: Quarenta ratos, wistar, machos com três meses de idade, foram submetidos à dissecação bilateral dos ductos deferentes seguidos do implante da tela de polipropileno em um dos lados, tomando-se o lado contra-lateral como seu controle. Os animais foram sacrificados após 90 (Grupo I) e 120 (Grupo II) dias de pós-operatório, e os ductos deferentes, epidídimos e testículos avaliados histopatologicamente por microscopia óptica. Na análise estatística foram utilizados os testes de ?t? de Student e comparação de proporções. Resultados: Houve reação inflamatória tipo corpo estranho em todos os segmentos do ducto deferente exposto à tela e a montante desta, mas em nenhum no lado controle. Não houve obstrução completa do lúmen dos ductos deferentes expostos à tela de polipropileno em nenhum dos animais. O lúmen do ducto deferente apresentou dilatação a montante da tela em relação ao lado controle tanto no grupo I, que apresentou área média de 0,46441 mm², quanto no grupo II, área média de 0,37052 mm², no segmento controle do grupo I a área média foi de 0,2394 mm² e grupo II de 0,20789 mm², e as diferenças entre estes segmentos foram significativas (grupo I: p=0,002 / grupo II: p=0,044). Nos segmentos à montante da tela dos grupos I e II evidenciou-se a presença de espermatozóides no lúmen em 100% dos cortes histológicos, e nos controles de ambos os grupos a presença de espermatozóides ocorreu em 73,68%, sendo estas diferenças significativas (grupo I: p=0,009 / grupo II: p=0,022). A espessura da parede do ducto deferente foi significativamente menor nos segmentos expostos à tela (média de 0,15952 mm / p=4,348E-5) e a montante destes (média de 0,08348 mm / p=9,719E-10) em relação ao ducto deferente controle (média de 0,29968 mm) no grupo I. No grupo II, a espessura média foi de 0,294 mm e 0,1553 mm respectivamente nos segmentos exposto à tela e a montante desta, e 0,3034 mm no controle, apresentando significância apenas entre o segmento a montante da tela e o controle neste grupo (p=0,001). Houve perda do aspecto festonado da mucosa do ducto deferente em todos os segmentos à montante e nenhum no lado controle em ambos os grupos. Nenhum animal apresentou alterações significativas dos epidídimos e testículos, exceto um que apresentou atrofia testicular por provável torção do cordão espermático durante o ato operatório. Conclusão: A tela de polipropileno induz reação inflamatória, a qual resulta em alterações histológicas do ducto deferente que levam à dilatação e represamento de espermatozóides à montante da tela, assim como diminuição da espessura da parede do ducto deferente nos segmentos expostos à tela e à montante dela / Abstract: Background: Vas deferens lesions, leading to infertility, may occur in 6.65% to 26.7% of inguinal herniorraphy. Tension-free herniorraphy using polypropylene mesh, which induces an inflammatory process and adjacent fibrosis, strengthening the posterior inguinal wall, has become very popular. However its histological and physiological effects are not completely known. Objective: This study intended to evaluate the effects of polypropylene mesh in the rat vas deferens. Method: Forty, three-month-old male Wistar rats underwent bilateral vas deferens dissection, followed by mesh implantation on one side. The contra-lateral side was the control. The animals were sacrificed after 90 (Group I) and 120 (Group II) postoperative days. The vas deferens, epididymis and testicles underwent histopathological assessment. Statistics methods used were the ?t? test and the compare proportion. Results: A foreign body reaction occurred after implantation in all animals. Control presented no reaction. The mean lumen dilation in regions before mesh was 0.46441mm² and 0.37052mm², in Group I and II, respectively, and all sections presented spermatozoids. The mean dilation in control rats of Groups I and II was 0.2394mm² and 0.20789mm², respectively and spermatozoids were present in 73,68%. Those differences, between experimental and control animals were significant (group I: p=0,002 / group II: p=0,044). In Group I the average wall thickness of vas deferens segments exposed to mesh was 0.15952mm and the average wall thickness segments before mesh was 0.08348mm while the average wall thickness of control vas deferens was 0.29968mm (p=9,719E-10). In Group II, the mean wall thickness of vas deferens exposed to mesh and before mesh segments was 0.294mm and 0.1553mm, respectively, while the control was 0.3034mm (p=0,001). Mucosal fold loss occurred in all segments before mesh but none in the control. The epididymis and testicles presented no alterations. Conclusion: Polypropylene mesh induces a foreign body reaction with histological alterations in the vas deferens that cause functional obstruction with dilation and spermatozoid repression / Mestrado / Cirurgia / Mestre em Cirurgia
10

Resultados tardios do uso de próteses no tratamento cirúrgico das grandes hérnias de hiato / Late results of mesh used in the surgical treatment of large hiatal hernias

Brandalise, André, 1970- 27 August 2018 (has links)
Orientador: Nelson Adami Andreollo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-27T00:10:08Z (GMT). No. of bitstreams: 1 Brandalise_Andre_D.pdf: 14069828 bytes, checksum: d178e5d4a6b617f687e38a9c3855f1b7 (MD5) Previous issue date: 2015 / Resumo: Introdução: o tratamento cirúrgico da doença do refluxo gastroesofágico através da fundoplicatura realizada por videolaparoscopia apresenta bons resultados a longo prazo e é amplamente aceita como alternativa à manutenção do tratamento medicamentoso. Entretanto, a abordagem cirúrgica aos pacientes portadores de grandes hérnias de hiato ainda é motivo de discordância entre os especialistas. O uso de prótese para reforçar a hiatoplastia é proposta por alguns e descartada por outros, especialmente por temor de complicações relacionadas à prótese. Objetivo: realizar uma análise dos resultados a longo prazo do uso de próteses para reforço da hiatoplastia em pacientes com grandes hérnias de hiato tratadas por videolaparoscopia. Método: realizamos análise retrospectivo com 78 pacientes operados entre janeiro de 2000 e fevereiro de 2011 que eram portadores de grandes hérnias e que foram tratados através de cirurgia videolaparoscópica com emprego de próteses para reforço da hiatoplastia. Foram incluídos no estudo pacientes com tamanho do hiato superior a 5 cm de diâmetro, em hérnias primárias ou recidivadas. As próteses estudadas foram: polipropileno ¿ em modelo de implantação original, desenvolvido em nosso serviço ¿ e biológica absorvível. O acompanhamento foi realizado através de entrevista clínica e exames complementares ¿ endoscopia digestiva alta e/ou radiografias contrastadas de esôfago, estômago e duodeno. Resultados: observou-se maior presença de pacientes do sexo feminino (69%). A idade variou de 33 a 83 anos. A média de idade nos pacientes com hérnias primárias foi 64,7 anos, enquanto que nas hérnias recidivadas, foi de 52,3 anos. Essa diferença foi estatisticamente significante (p=0,0001). O tempo de seguimento médio foi de 45,8 meses para hérnias primárias e 61,4 meses para as recidivadas. (p=0,09). Na entrevista, 64 pacientes (82,0%) permaneciam assintomáticos, 7 (9,0%) queixavam-se de refluxo, 3 (3,9%) apresentavam disfagia e 4 (5,2%) relataram problemas com gases. Foram realizados exames complementares em 68 pacientes (87,2%). Destes 54 (79,4%) apresentavam exames normais, enquanto 14 (20,6%) apresentavam recidiva (da hérnia ou de esofagite). No grupo de hérnia primária ocorreram recidivas em seis pacientes (13%) e no grupo de hérnias recidivadas, oito (36,4%) apresentaram nova recorrência e essa diferença foi estatisticamente significante (p=0,05). Segundo o tipo de prótese, nos pacientes em que foi empregada a prótese de polipropileno, 13,5% apresentavam recidiva anatômica enquanto que na prótese biológica este valor foi de 31,2%, mas essa diferença observada não atingiu nível de significância estatística (p=0,13). Não foram observadas complicações relacionadas à prótese. Conclusão: O uso de prótese de polipropileno, segundo o modelo apresentado, é seguro a longo prazo e tem baixos índices de recidiva a longo prazo. A prótese biológica apresentou maiores índices de recidiva. Nas hérnias de hiato recidivas, os índices de recidiva são maiores que nas hérnias primárias / Abstract: Introduction: the surgical treatment of gastroesophageal reflux disease by laparoscopic fundoplication has good long-term results and is widely accepted as an alternative to the maintenance of medical treatment. However, surgical approach to patients with large hiatal hernias still causes disagreement among the experts. The use of prosthesis to enhance hiatus is proposed by some and dismissed by others, especially for fear of complications related to the prosthesis. Objective: To perform an analysis of long-term results of the use of prostheses for strengthening hiatoplasty in patients with large hernias treated by laparoscopy. Method: We performed a retrospective analysis of 78 patients operated between January 2000 and February 2011 with large hernias treated by laparoscopic surgery with the use of prostheses for strengthening hiatoplasty. The study included patients with hiatos larger than 5 cm in diameter, in primary or recurrent hernias. The prostheses were: polypropylene - in original model of implementation, developed in our service - and absorbable biological. The monitoring was performed by clinical interview and objective tests - endoscopy and / or barium contrast x-rays of esophagus, stomach and duodenum. Results: there was a higher presence of female patients (69%). The age ranged 33-83 years. The mean age of the patients was 64.7 years in primary hernias, whereas in the recurrent hernias, was 52.3 years. This difference was statistically significant (p = 0.0001). The mean follow-up was 45.8 months for primary hernias and 61.4 months for recurrent. (p = 0.09). In the interview, 64 patients (82.0%) remained asymptomatic, 7 (9.0%) complained of reflux, 3 (3.9%) had dysphagia and 4 (5.2%) reported problems with gas. Objective tests were performed in 68 patients (87.2%). Of these 54 (79.4%) had normal results, while 14 (20.6%) had recurrence (hernia or esophagitis). In the primary hernia group relapses occurred in six patients (13%) and in the recurrent hernia group, eight (36.4%) had recurred and this difference was statistically significant (p = 0.05). According to the type of prosthesis, in patients in whom we used the polypropylene prosthesis, 13.5% had anatomic recurrence while on the biological prosthesis this value was 31.2%, but this difference did not reach statistical significance level (p = 0.13). There were no complications related to the prosthesis. Conclusion: The use of polypropylene mesh, according to the presented model, is safe in the long term and have low recurrence rates. The biological prostheses showed higher recurrence rates. In patientes with recurrent hernias, the recurrence rates are higher than in primary hernias / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências

Page generated in 0.464 seconds