• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 332
  • 137
  • 34
  • 20
  • 14
  • 12
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 652
  • 652
  • 251
  • 152
  • 143
  • 115
  • 100
  • 96
  • 95
  • 83
  • 78
  • 63
  • 62
  • 61
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

FAULT DIAGNOSIS OF ELECTRONIC FUEL CONTROL (EFC) VALVES VIA DYNAMIC PERFORMANCE TEST METHOD

Tugsal, Umut January 2009 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Electronic Fuel Control (EFC) valve regulates fuel flow to the injector fuel supply line in the Cummins Pressure Time (PT) fuel system. The EFC system controls the fuel flow by means of a variable orifice that is electrically actuated. The supplier of the EFC valves inspects all parts before they are sent out. Their inspection test results provide a characteristic curve which shows the relationship between pressure and current provided to the EFC valve. This curve documents the steady state characteristics of the valve but does not adequately capture its dynamic response. A dynamic test procedure is developed in order to evaluate the performance of the EFC valves. The test itself helps to understand the effects that proposed design changes will have on the stability of the overall engine system. A by product of this test is the ability to evaluate returned EFC valves that have experienced stability issues. The test determines whether an EFC valve is faulted or not before it goes out to prime time use. The characteristics of a good valve and bad valve can be observed after the dynamic test. In this thesis, a mathematical model has been combined with experimental research to investigate and understand the behavior of the characteristics of different types of EFC valves. The model takes into account the dynamics of the electrical and mechanical portions of the EFC valves. System Identification has been addressed to determine the transfer functions of the different types of EFC valves that were experimented. Methods have been used both in frequency domain as well as time domain. Also, based on the characteristic patterns exhibited by the EFC valves, fuzzy logic has been implemented for the use of pattern classification.
152

A Control Theoretic Approach for Resilient Network Services

Vempati, Jagannadh Ambareesh 12 1900 (has links)
Resilient networks have the ability to provide the desired level of service, despite challenges such as malicious attacks and misconfigurations. The primary goal of this dissertation is to be able to provide uninterrupted network services in the face of an attack or any failures. This dissertation attempts to apply control system theory techniques with a focus on system identification and closed-loop feedback control. It explores the benefits of system identification technique in designing and validating the model for the complex and dynamic networks. Further, this dissertation focuses on designing robust feedback control mechanisms that are both scalable and effective in real-time. It focuses on employing dynamic and predictive control approaches to reduce the impact of an attack on network services. The closed-loop feedback control mechanisms tackle this issue by degrading the network services gracefully to an acceptable level and then stabilizing the network in real-time (less than 50 seconds). Employing these feedback mechanisms also provide the ability to automatically configure the settings such that the QoS metrics of the network is consistent with those specified in the service level agreements.
153

Simulation and characterisation of a concentrated solar power plant / Coenraad Josephus Nel

Nel, Coenraad Josephus January 2015 (has links)
Concentrated solar power (CSP) is an efficient means of renewable energy that makes use of solar radiation to produce electricity instead of making use of conventional fossil fuel techniques such as burning coal. The aim of this study is the simulation and characterisation of a CSP plant in order to gain a better understanding of the dominant plant dynamics. Due to the nature of the study, the dissertation is divided into two main parts namely the simulation of a CSP plant model and the characterisation of the plant model. Modelling the CSP plant takes the form of developing an accurate Flownex® model of a 40 MW combined cycle CSP plant. The model includes thermal energy storage as well as making use of a duct burner. The Flownex® model is based on an existing TRNSYS model of the same plant. The Flownex® model is verified and validated, by making use of a bottom-up approach, to ensure that the developed model is in fact correct. The characterisation part of this dissertation involves evaluating the dynamic responses unique to that of a CSP plant as stated in the literature. This involves evaluating the dominant dynamic behaviour, the presence of resonant and anti-resonant modes found within the control bandwidth, and the change in the dynamics of the plant as the plants’ operating points change throughout the day. Once the developed model is validated, characterisation in the form of evaluating the open loop local linear models of the plant is implemented. In order to do so, these models are developed based on model identification processes, which include the use of system identification software such as Matlab® SID Toolbox®. The dominant dynamic behaviour of the plant model, obtained from the developed local linear models, represents that of an over damped second order system that changes as the operating points of the plant change; with the models’ time responses and the bandwidth decreasing and increasing respectively as the thermal energy inputs to the plant increases. The frequency response of the developed local linear models also illustrates the presence of resonant and antiresonant modes found within the control bandwidth of the solar collector field’s temperature response. These modes however are not found to be present in the mechanical power output response of the plant. The use of adaptive control, such as feedforward and gain-scheduled controllers, for the plant should be developed to compensate for the dynamic behaviours associated with that of a CSP plant. / MIng (Computer and Electronic Engineering), North-West University, Potchefstroom Campus, 2015
154

Simulation and characterisation of a concentrated solar power plant / Coenraad Josephus Nel

Nel, Coenraad Josephus January 2015 (has links)
Concentrated solar power (CSP) is an efficient means of renewable energy that makes use of solar radiation to produce electricity instead of making use of conventional fossil fuel techniques such as burning coal. The aim of this study is the simulation and characterisation of a CSP plant in order to gain a better understanding of the dominant plant dynamics. Due to the nature of the study, the dissertation is divided into two main parts namely the simulation of a CSP plant model and the characterisation of the plant model. Modelling the CSP plant takes the form of developing an accurate Flownex® model of a 40 MW combined cycle CSP plant. The model includes thermal energy storage as well as making use of a duct burner. The Flownex® model is based on an existing TRNSYS model of the same plant. The Flownex® model is verified and validated, by making use of a bottom-up approach, to ensure that the developed model is in fact correct. The characterisation part of this dissertation involves evaluating the dynamic responses unique to that of a CSP plant as stated in the literature. This involves evaluating the dominant dynamic behaviour, the presence of resonant and anti-resonant modes found within the control bandwidth, and the change in the dynamics of the plant as the plants’ operating points change throughout the day. Once the developed model is validated, characterisation in the form of evaluating the open loop local linear models of the plant is implemented. In order to do so, these models are developed based on model identification processes, which include the use of system identification software such as Matlab® SID Toolbox®. The dominant dynamic behaviour of the plant model, obtained from the developed local linear models, represents that of an over damped second order system that changes as the operating points of the plant change; with the models’ time responses and the bandwidth decreasing and increasing respectively as the thermal energy inputs to the plant increases. The frequency response of the developed local linear models also illustrates the presence of resonant and antiresonant modes found within the control bandwidth of the solar collector field’s temperature response. These modes however are not found to be present in the mechanical power output response of the plant. The use of adaptive control, such as feedforward and gain-scheduled controllers, for the plant should be developed to compensate for the dynamic behaviours associated with that of a CSP plant. / MIng (Computer and Electronic Engineering), North-West University, Potchefstroom Campus, 2015
155

Black-Box Modeling and Attitude Control of a Quadcopter

Kugelberg, Ingrid January 2016 (has links)
In this thesis, black-box models describing the quadcopter system dynamics for attitude control have been estimated using closed-loop data. A quadcopter is a naturally unstable multiple input multiple output (MIMO) system and is therefore an interesting platform to test and evaluate ideas in system identification and control theory on. The estimated attitude models have been shown to explain the output signals well enough during simulations to properly tune a PID controller for outdoor flight purposes. With data collected in closed loop during outdoor flights, knowledge about the controller and IMU measurements, three decoupled models have been estimated for the angles and angular rates in roll, pitch and yaw. The models for roll and pitch have been forced to have the same model structure and orders since this reflects the geometry of the quadcopter. The models have been validated by simulating the closed-loop system where they could explain the output signals well. The estimated models have then been used to design attitude controllers to stabilize the quadcopter around the hovering state. Three PID controllers have been implemented on the quadcopter and evaluated in simulation before being tested during both indoor and outdoor flights. The controllers have been shown to stabilize the quadcopter with good reference tracking. However, the performance of the pitch controller could be improved further as there have been small oscillations present that may indicate a stronger correlation between the roll and pitch channels than assumed.
156

A Study of Impulse Response System Identification

Paluri, Suraj, Patluri, Sandeep January 2007 (has links)
In system identification, different methods are often classified as parametric or non-parametric methods. For parametric methods, a parametric model of a system is considered and the model parameters are estimated. For non-parametric methods, no parametric model is used and the result of the identification is given as a curve or a function. One of the non-parametric methods is the impulse response analysis. This approach is dynamic simulation. This thesis introduces a new paradigm for dynamic simulation, called impulse-based simulation. This approach is based on choosing a Dirac function as input, and as a result, the output will be equal to the impulse response. However, a Dirac function cannot be realized in practice, and an approximation has to be used. As a consequence, the output will deviate from the impulse response. Once the impulse response is estimated, a parametric model can be fitted to the estimation. This thesis aims to determine the parameters in a parametric model from an estimated impulse response. The process of investigating the models is a critical aspect of the project. Correlation analysis is used to obtain the weighting function from the estimates of covariance functions. Later, a relation formed between the parameters and the estimates (obtained by correlation analysis) in the form of a linear system of equations. Furthermore, simulations are carried out using Monte Carlo for investigating the properties of the two step approach, which involves in correlation analysis to find h-parameters and least squares and total least squares methods to solve for the parameters of the model. In order to evaluate the complete capability of the approach to the noise variation a study of signal to noise ratio and mean, mean square error and variances of the estimated parameters is carried out. The results of the Monte Carlo study indicate that two-step approach can give rather accurate parameter estimates. In addition, the least squares and total least squares methods give similar results.
157

Modeling and Temperature Control of an Industrial Furnace

Carlborg, Hampus, Iredahl, Henrik January 2016 (has links)
A linear model of an annealing furnace is developed using a black-box system identification approach, and used when testing three different control strategies to improve temperature control. The purpose of the investigation was to see if it was possible to improve the temperature control while at the same time  decrease the switching frequency of the  burners. This will lead to a more efficient process as well as less maintenance, which has both economic and environmental benefits. The estimated model has been used to simulate the furnace with both the existing controller and possible new controllers such as a split range controller and a model predictive controller (MPC). A split range controller is a control strategy which can be used when more than one control signal affect the output signal, and the control signals have different range. The main advantage with MPC is that it can take limitations and constraints into account for the controlled process, and with the use of integer programming, explicitly account for the discrete switching behavior of the burners. In simulation both new controllers succeed in decreasing the switching and the MPC also improved the temperature control. This suggest that the control of the furnace can be improved by implementing one of the evaluated controllers.
158

Identification and Simulation Methods for Nonlinear Mechanical Systems Subjected to Stochastic Excitation

Josefsson, Andreas January 2011 (has links)
With an ongoing desire to improve product performance, in combination with the continuously growing complexity of engineering structures, there is a need for well-tested and reliable engineering tools that can aid the decision making and facilitate an efficient and effective product development. The technical assessment of the dynamic characteristics of mechanical systems often relies on linear analysis techniques which are well developed and generally accepted. However, sometimes the errors due to linearization are too large to be acceptable, making it necessary to take nonlinear effects into account. Many existing analysis techniques for nonlinear mechanical systems build on the assumption that the input excitation of the system is periodic and deterministic. This often results in highly inefficient analysis procedures when nonlinear mechanical systems are studied in a non-deterministic environment where the excitation of the system is stochastic. The aim of this thesis is to develop and validate new efficient analysis methods for the theoretical and experimental study of nonlinear mechanical systems under stochastic excitation, with emphasis on two specific problem areas; forced response simulation and system identification from measurement data. A fundamental concept in the presented methodology is to model the nonlinearities as external forces acting on an underlying linear system, and thereby making it possible to use much of the linear theories for simulation and identification. The developed simulation methods utilize a digital filter to achieve a stable and condensed representation of the linear subparts of the system which is then solved recursively at each time step together with the counteracting nonlinear forces. The result is computationally efficient simulation routines, which are particularly suitable for performance predictions when the input excitation consist of long segments of discrete data representing a realization of the stochastic excitation of the system. Similarly, the presented identification methods take advantage of linear Multiple-Input-Multiple-Output theories for random data by using the measured responses to create artificial inputs which can separate the linear system from the nonlinear parameters. The developed methods have been tested with extensive numerical simulations and with experimental test rigs with promising results. Furthermore, an industrial case study of a wave energy converter, with nonlinear characteristics, has been carried out and an analysis procedure capable of evaluating the performance of the system in non-deterministic ocean waves is presented.
159

Ett flervariabelt feldetekteringssystem för övervakning av bärlagertemperaturen i vattenkraftturbiner

Fredlund, Henrik January 2004 (has links)
<p>The purpose of this thesis work was to develop an automatic fault detection system for surveillance of bearing temperature in hydropower turbines. The parameters used except the bearing temperature were cooling water temperature and cooling water flow. A simple static model based on data sampled every minute was developed to estimate the bearing temperature. Then a detector for detection of change in bearing temperature based on the CUSUM-algorithm was designed. Since the amount of data was very small the developed model was too uncertain to be used in a working system.</p><p>The designed fault detection system showed to work well for the available data. It is, however, recommended that the performance of the system should be evaluated using more data. Another model based on data sampled once every minute for at least a year has to be developed before the system can be fully evaluated. The results shown were:</p><p>• The fault detection system can discover fast and slow changes in bearing temperature.</p><p>• No false alarms were given for measuring faults and sensor faults of the types used in this thesis. If a measuring fault occurs for too long there will be an alarm.</p><p>The fault detection algorithm was also implemented in Delphi to be used in a working system over the Internet where for example trends and alarms will be presented.</p> / <p>Syftet med examensarbetet var att utveckla ett automatiskt feldetekteringssystem för övervakning av bärlagertemperaturen i vattenkraftturbiner. De ingående parametrarna förutom bärlagertemperaturen var kylvattentemperaturen och kylvattenflödet. En enkel statisk modell baserad på data samplat en gång per minut togs fram för att estimera bärlagertemperaturen. Därefter utvecklades en detektor för att upptäcka avvikelser i bärlagertemperaturen baserad på CUSUM-algoritmen. På grund av en för liten mängd data var den framtagna modellen alltför osäker för att kunna implementeras i ett fungerande system.</p><p>Det framtagna feldetekteringssystemet visade sig fungera bra för de data som fanns tillgängliga. Det är däremot rekommenderat att utvärdera systemets prestanda med längre dataserier. En ytterligare modell baserad på minutdata över ett år måste tas fram innan systemet kan fungera på riktigt. De resultat som erhölls var:</p><p>• Feldetekteringssystemet klarar av att upptäcka abrupta och långsamma avvikelser av bärlagertemperaturen.</p><p>• Inga falsklarm ges då det är enstaka mätfel eller givarfel av sådan typ som tagits upp i arbetet. Pågår ett mätfel alltför länge ges dock ett larm.</p><p>Feldetekteringsalgoritmen implementerades även i Delphi för att kunna användas i ett fungerande system över Internet där t.ex. trendkurvor och larmsignaler skall kunna presenteras.</p>
160

System Identification of Irrigation Channels with Overshot and Undershot gates / Systemidentifiering av bevattningskanaler med olika typer av luckor

Euren, Karin January 2004 (has links)
<p>I Australien är vattenresurserna begränsade. För lantbrukare är tillgängligheten på vatten mycket viktig. På grund av det torra klimatet kan inte de Australiensiska bönderna förlita sig på nederbörden. Bevattningssystemen är därför en viktig del i jordbrukningsindustrin.</p><p>Bevattningsområdet i Coleambally ligger i södra New South Wales nära gränsen till staten Victoria. Bevattningsnätet i Coleambally förser ofta bevattningskanalerna med för mycket vatten för att vara säker på att lantbrukarna får den mängd vatten de behöver. På grund av denna tillförsel av överskottvatten går stor mängd av vatten förlorad. Design av ett bättre reglersystem skulle kunna minska den stora förlusten av vatten.</p><p>En matematisk modell beskrivande dynamiken av bevattningssystemet är ett bra redskap vid en design av ett bättre reglersystem. Syftet med det här projektet var att genom systemidentifiering bygga en matematisk modell av bevattningssystemet. Modellen syftade till att beskriva vattennivån i en sträcka av bevattningskanalerna, sträckan i kanalen skulle ha två olika typer av luckor, en typ där vattnet strömmar över luckan och en annan typ där vattnet strömmar under luckan. En modell byggdes genom att parametrar från en vald modellstruktur estimerades från experimentella data. Data samlades under ett experiment som utfördes på en bevattningskanal i Coleambally.</p><p>Resultatet från systemidentifieringen blev en första ordningens output error grey box modell. Modellen visar goda resultat vid validering och bör kunna användas vid design av ett bättre reglersystem. Modellen visar så god överensstämmelse med valideringsdata att den även kan användas för olika fall av simulering.</p> / <p>Water resources in Australia are limited. For a farmer the access to water is crucial and due to the dry climate the farmers in Australia can not rely on precipitation. Irrigation is therefore a very important part of the farming industry.</p><p>The Coleambally Irrigation Area is situated in the southern parts of New South Wales close to the border of Victoria. The Irrigation Network often supplies the irrigation channels with too much water to be sure that the demand of water is satisfied. Due to this over supply a great amount of water gets wasted. Design of a bettercontrol system would be able to reduce the water wastage.</p><p>A mathematical model describing the dynamics of the irrigation system can be used as a tool for the control system design. The aim of this project was to build a mathematical model with the system identification approach. The model should be able to describe the downstream water level of a single pool of an irrigation channel which has both undershot and overshot gates. A model was built by estimating unknown parameters of a chosen model structure from a set of experimental data. The data was collected from an experiment performed on the real irrigation system in Coleambally.</p><p>The result of the system identification was a first order output error grey box model. The model performs well on validation data and may therefore be used for design of a more efficient control system. The model gave such good results that it additionally may be used for various simulation purposes.</p>

Page generated in 0.1083 seconds