• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Bioacumulação de íons de Pb+² na macrófita Salvinia auriculata / Of the lead ions bioaccumulation process by living aquatic macrophytes Salvinia auriculata

Thomé, Luciara Ciane Port 13 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:07Z (GMT). No. of bitstreams: 1 Luciara Ciane Port Thome.pdf: 1696527 bytes, checksum: f809752851373066f0420949b0b14357 (MD5) Previous issue date: 2008-02-13 / In this work was carried out a study of the lead bioaccumulation process by living aquatic macrophytes Salvinia auriculata. Initially, they were performed toxicological and growing tests in order to determine the non-toxic lead concentration limits and the minimum amount of biomass for the lead uptake experiment duration. The bioaccumulation experiment was performed using young and healthy floating aquatic plants of species S. auriculata. Approximately 30 grams of S. auriculata were put in growing at several 8-L recipients containing 5 L hydroponics solution and a non-toxic lead concentration of 2 mg L-1, during 29 days in a greenhouse. For the lead uptake experiment, seven collection times were set up at intervals of 1, 2, 5, 8, 22 and 29 days, including the zero time and was measured the growing solution temperature and pH, and the solution volume was monitored and deionized water was added to compensate the losses by evaporation. In order to measure the total lead concentration accumulated in aqueous solution obtaining from roots and leaves and growing solution, a Synchrotron Radiation Total Reflection X-Ray Fluorescence technique was used. The lead removal factor by S. auriculata after 29 days, in experimental conditions, was around 87 %. Moreover, it was observed a strong reduction of 50 % of lead concentration in liquid phase and lead accumulation in roots after the first 24 hours of experiment, while there a constant lead concentration in roots after the second day, indicating the transport and accumulation of lead into the leaves. The lead adsorption experimental data by S. auriculata were modeling by the irreversible adsorption kinetic of Langmuir. In the model, the equation system was resolved by DASSL algorithm and the kinetic parameters were obtained and optimized by an objective function using a SIMPLEX algorithm. The adsorption rate constant (k) value was 0.12 L d mg-1 Pb+2 while the maximum lead contents (qmax) value in the biomass was 0.15 mg Pb+2 g-1. The aquatic plant S. auriculata can be a good alternative for effluent treatment through both bioadsorption and bioaccumulation mechanism. The process based on the Phytoremediation technique using aquatic plants have become a attractive economical process due to its easy applicability , low operational costs and high efficiency. / Neste trabalho foi realizado um estudo do processo de bioacumulação de Pb+2 pela macrófita aquática Salvinia auriculata. Realizaram-se inicialmente testes toxicológicos e de crescimento para determinar os níveis tóxicos de Íons de Pb+2, estipular a massa mínima adequada, duração da experiência e os intervalos de coleta para o experimento da bioacumulação. O experimento da bioacumulação foi conduzido utilizando plantas jovens e sadias da espécie aquática e flutuante S. auriculata. Foram cultivadas, durante 29 dias em estufa, aproximadamente 30 gramas em recipiente de 8 L, em várias réplicas, contendo 5 litros de uma solução hidropônica (de Clark) e uma concentração não tóxica de 2 mg Pb+2 L-1. Foram realizadas 7 coletas, incluindo a coleta 0, a intervalos de 1, 2, 5, 8, 22 e 29 dias, monitorando pH e temperatura e fazendo a reposição de água devido a perdas por evaporação. As concentrações totais de chumbo, tanto na fase fluida como na raiz e na folha, foram determinadas pela técnica SR-TXRF. O fator de remoção de chumbo pela salvinia após 29 dias de cultivo, nas condições estudadas, foi de 87 %. Além disso, foi observado que a adsorção de chumbo foi rápida nas primeiras 24 horas, reduzindo em aproximadamente 50 %. A partir do segundo dia, a concentração de chumbo é quase constante, indicando a ocorrência de transporte e acumulação de chumbo na folha. Os dados experimentais de adsorção de Íons de Pb+2 pela S. auriculata foram representados pelo modelo cinético irreversível de Langmuir. No ajuste dos dados experimentais pelo modelo proposto, utilizou-se de uma função objetivo para otimizar os parâmetros de adsorção: a constante da taxa de adsorção e a quantidade máxima de sítios disponíveis na biomassa, cujos valores obtidos foram k = 0,12 L d mg-1 Pb+2 e qmax = 0,15 mg Pb+2 g-1. A planta S. auriculata mostrou-se uma boa opção para tratamento de efluentes através dos mecanismos de adsorção e bioacumulação. O processo de remoção de metal por planta aquática comprovou ser economicamente atrativo, de fácil disponibilidade, baixos custos operacionais e alta eficiência.
2

Estudo da bioacumulação de cobre e chumbo pela macrófita aquática Eicchornia crassipes em solução hidropônica / Bioaccumulation study of copper and lead by the Eicchornia crassipes in hydroponic solution

Szymanski, Nayara 11 February 2011 (has links)
Made available in DSpace on 2017-07-10T18:08:01Z (GMT). No. of bitstreams: 1 Nayara Szymanski.pdf: 2166541 bytes, checksum: d5ebf09357be44af458b98aeeb5d43bc (MD5) Previous issue date: 2011-02-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Aquatic macrophytes are known to remove heavy metals from the surface by adsorption or absorption and incorporate them into systems, in different ways. The main objective of this work is to study the multicomponent bioaccumulation of copper and lead by the living aquatic macrophyte Eicchornia crassipes. The experiments were performed in triplicate using about 30g healthy young plants and 5L Clark s hydroponic solution doped with non-toxic concentration of copper and lead metals combined. All experiments have been carried out in a greenhouse, for 20 days, monitoring the loss of water volume and adding deionized water as it was needed. Samples were performed in predetermined collection times (2, 4, 7, 12 and 20 days) to determined the metal content by the synchrotron radiation reflection X-ray fluorescence technique (SR-TXRF), and the measurements of SR-TXRF were performed at the Brazilian Light Synchrotron Laboratory (LNLS). It was observed that at least 90% metal concentration was removed of all experiments by bioaccumulation process, this indicates that the adsorption process is quick in roots, but slow if accumulation process takes place in aerial parts. The kinetics of biosorption that better fits the experimental data was Irreversible Langmuir for Cu and Pb, and Pseudo-first order and Pseudo-second order for Cu and Pb, respectively at the multicomponent experiment. / Macrófitas aquáticas são conhecidas por removerem metais pesados pela superfície, por adsorção ou absorção, e incorporá-los em seu sistema de diversas formas. O objetivo principal deste trabalho é estudar a remoção multicomponente de cobre e chumbo pela macrófita aquática flutuante Eicchornia crassipes viva. Experimentos foram realizados em triplicata, utilizando em média 30 gramas de plantas, jovens e sadias em 5L de solução hidropônica de Clark dosada a uma concentração não tóxica de metais cobre e chumbo em três combinações. Todos os experimentos foram conduzidos em estufa externa, durante 20 dias, monitorando-se o nível do volume de água pela adição de água deionizada quando necessário. Coletas de amostras foram feitas em tempos pré-determinados (2, 4, 7, 12 e 20 dias). A determinação das quantidades de metais foi feita utilizando-se da técnica de espectroscopia de Raios-X por Reflexão Total (SR-TXRF), e as medidas de SR-TXRF foram efetuadas no Laboratório Nacional de Luz Síncrotron (LNLS). Foi observada redução de até 90% nos valores de concentração dos metais, nos experimentos realizados, indicando que cobre e chumbo foram removidos pela macrófita pelo processo de bioacumulação, ou seja, rápida adsorção pelas raízes e um lento processo de acumulação nas partes aéreas. As cinéticas de biossorção que melhor ajustaram-se aos dados experimentais foram de Langmuir Irreversível para Cu e Pb, e de Pseudo-primeira ordem e Pseudo-segunda ordem para Cu e Pb, respectivamente no experimento multicomponente.
3

Aplicação da técnica de eletro-floculação no tratamento de efluentes de curtume / Application of electroflocculation technique for the tannery effluent treatment

Fornari, Marilda Menchon Tavares 12 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:07Z (GMT). No. of bitstreams: 1 Marilda M T Fornari.pdf: 813038 bytes, checksum: 1672b5ca9a95a70d2125540cf442fb8a (MD5) Previous issue date: 2008-02-12 / In the present work has been studied the electro-flocculation efficiency on the reduction of organic and inorganic material concentrations such as Chemical Oxygen Demand (COD), turbidity, total solids and metal, mainly chromium, on an untreated tannery effluent using a pair of electrodes. For this purpose, a lab scale Electro-Flocculation (EF) reactor was constructed using an 8-L plastic cylindrical container, containing a valve in its lower part for sludge evacuation and a horizontal support in its upper part for fixing a pair of electrolytic cell in upright position into a 5-L available reactor volume. The electrodes plates, made of iron or aluminum, were connected to terminals of direct current power supply. All the physical-chemistry parameters were measured following the Standard Methods for water analysis, while metal concentrations were determined using the Synchrotron X-Ray Fluorescence technique, available in the Brazilian Synchrotron Light Laboratory. In order to determine optimal operating conditions, the effects of current intensity, electrodes distance, effluent initial pH, and EF time have been experimentally examined, according to a statistic planning and correlation analysis. For each electrode, a total of 11 EF experiments were carried out for maximum and minimum values of EF reactor operating parameters. Applying a 95% confidence level into the correlation analysis between EF parameters, the physical-chemistry parameters and metal concentrations were reduced in all of them when the effluent initial pH was increased, while the EF time and the applied voltage were reduced for small electrodes distances. Moreover, the EF treatment efficiencies tend towards higher values with an increasing on the current intensity. In order to determine the best reactor operating values, other EF experiments were performed varying the effluent initial pH from 6.5 to 9.0 and from 6.0 to 8.5 for iron and aluminum electrodes, respectively, fixing the distance between the electrodes in 4.0 cm, the current intensity in 5.5 A and the EF time in 30 minutes. Nevertheless, these EF experiments have shown that the reduction factor on parameter concentrations due to an increasing of effluent initial pH was not significant compared to prior experiments. Henceforth, the effluent pH value was maintained near to the original one for the next EF treatments, avoiding introducing other substances into the effluent. Keeping effluent pH value in 7.5, other EF experiments were performed changing the EF time from 15 to 120 min., fixing current intensities and electrode distances in 5.5 A and 4.0 cm, respectively. For these reactor conditions, the EF time setting up in 30 min. was enough to get a good efficiency according the reduction factor in the most of parameters examined, without increasing a lot the reactor electrical power, for both kinds of electrodes. The EF reactor purpose and examined has shown a high efficiency on turbidity and chromium concentration reduction factor (98%). Furthermore, this system can be also used to reduce other elementary concentrations such as calcium, potassium and zinc, for both kinds of electrodes (Fe/Al). In comparison with iron electrodes, aluminum one has reported a better reduction factor (80%) on COD values and a good reduction factor (50%) on iron concentration. On the other hand, the EF method for tanneries effluent treatment system was also compared with conventional method using coagulating and flocculating agents, showing a great similarity between them in the reduction factor. In the EF method is not necessary to introduce substances to start the coagulation and flocculation process in effluent treatment. / Este trabalho tem por objetivo o estudo da eficiência da eletro-floculação na redução das concentrações de substâncias orgânicas e inorgânicas expressas através dos parâmetros: Demanda Química de Oxigênio (DQO), turbidez, sólidos totais e metais, principalmente o cromo, em efluente de curtume não tratado, utilizando um par de eletrodos. Para esse propósito foi construído, em escala laboratorial, um reator confeccionado a partir de um recipiente plástico de 8 litros, contendo uma válvula na parte inferior, para a retirada dos sedimentos, e um suporte horizontal na parte superior para a fixação do par de células eletrolíticas, em posição perpendicular dentro do reator com volume útil de 5 litros. As placas de eletrodos, de ferro e alumínio, foram conectadas a uma fonte de alimentação de energia.Todos os parâmetros físico-químicos foram determinados seguindo o Método Padrão para análise de água, enquanto que as concentrações de metal foram determinadas através da técnica de Fluorescência de Raios X por Reflexão Total, (SR-TXRF), disponível no Laboratório Nacional de Luz Síncroton. A fim de determinar as condições ótimas de operação, os efeitos da intensidade da corrente, distância entre eletrodos, pH inicial do efluente e tempo de eletrólise foram avaliados experimentalmente, de acordo com um planejamento estatístico e análise de correlação. Para cada eletrodo, foram realizados 11 experimentos de EF com valores máximos e mínimos para os parâmetros de operação do reator. Empregando um nível de 95% de confiança na correlação de análises dos parâmetros a análise de correlação entre os parâmetros de EF, os modelos mostraram tendência de redução nas concentrações dos parâmetros físico-químicos e de metais, quando o pH inicial do efluente foi elevado, enquanto o tempo de EF e a voltagem aplicada apresentaram tendência de redução nos valores para uma menor distância entre os eletrodos.. Além disso, a eficiência do tratamento de EF tende a valores mais elevados com o aumento na intensidade de corrente. A fim de determinar as melhores condições de operação do reator, outros experimentos EF foram feitos variando o pH inicial de 6.5 a 9.0 e de 6.0 a 8.5 para eletrodos de ferro e alumínio, respectivamente, fixando a distância entre os eletrodos em 4.0 cm, a intensidade da corrente em 5.5 A e o tempo de EF em 30 minutos. Entretanto, esses experimentos mostraram que o fator de redução percentual na concentração dos parâmetros, causada pelo aumento no pH inicial do efluente, não foi significativo comparado aos experimentos anteriores. Nos tratamentos posteriores de EF, o pH do efluente foi mantido próximo ao original, evitando a introdução de outras substâncias no efluente. Mantendo o valor do pH do efluente em 7.5, outros experimentos de EF foram realizados variando o tempo de eletrólise de 15 a 120 min., e fixando a intensidade da corrente e distância entre os eletrodos em 5.5 A e 4.0 cm., respectivamente. Nessas condições, o tempo de EF fixado em 30 min. foi suficiente para alcançar uma boa eficiência, de acordo com o fator de redução, para maioria dos parâmetros analisados, sem aumentar muito a potência elétrica do reator, para os dois tipos de eletrodos. Os experimentos realizados com reator de EF mostraram uma alta eficiência na redução da turbidez e concentração de cromo (98%). Ademais, esse sistema também pode ser utilizado na redução de outras concentrações elementares como cálcio, potássio e zinco, para ambos os tipos de eletrodos (Fe/Al). Em comparação com os eletrodos de ferro, o eletrodo de alumínio apresentou um melhor fator de redução nos valores de DQO (80%) e um bom fator de redução de ferro (50%). Por outro lado, o método de EF para o tratamento de sistema de efluentes de curtumes foi também comparado ao método convencional utilizando agentes coagulantes e floculantes, mostrando uma grande semelhança entre eles no fator de redução. No método EF não é necessário introduzir substâncias para iniciar o processo de coagulação e floculação no tratamento de efluente.

Page generated in 0.0246 seconds