Spelling suggestions: "subject:"atécnica dde oscilações forçadas"" "subject:"atécnica dde oscilações orçadas""
1 |
Condições mecânicas do sistema respiratório em adultos com fibrose cística: estudo pela espirometria, pletismografia e técnica de oscilações forçadas / Mechanics conditions of respiratory system in adults with systic bibrosis: study by spirometry, plethysmography and forced oscillation techniqueAdma do Nascimento Lima 23 June 2010 (has links)
Cystic fibrosis (CF) is an autosomal recessive disease more common in the white population, which leads to reduction in life expectancy. Pulmonary disease is the major cause of morbidity and mortality. The relevance of this study takes on a some factors: the drastic increase in median survival in the last 60 years in CF; the pulmonary pathophysiology remains not well understood; up to now there is no reported study using forced oscillation technique (FOT) exclusively in adults with CF. Thus the aims of this study are: to analyze the changes in respiratory mechanics in adults with CF by spirometry, plethysmography and FOT; correlate the results of FOT to the spirometric and plethysmographic data and evaluate the sensitivity and specificity of FOT in these individuals. This is a descriptive cross-sectional study enrolling two groups of individuals: control (n=23) and CF (n=27). The results were expressed by mean standard deviation. The techniques applied to evaluate the lung function were performed as follows: FOT, spirometry and plethysmography. The following parameters were evaluated by plethysmography: total lung capacity (TLC); functional residual capacity (FRC); residual volume (RV); FRC/TLC; RV/TLC; resistance airway (Rva) and specific airway conductance (SGva). On spirometry: first second forced expiratory volume (FEV1); forced vital capacity (FVC); forced expiratory flow between 25% and 75% of FVC (FEF25% - 75%) and the relations FEV1/ FVC (%) and FEF/FVC (%). In FOT: the resistance properties of the respiratory system - R0 (resistance at the intercept); medium resistance (Rm); slope of the linear resistance (S) and reactive properties: dynamic compliance of the respiratory system (Cdyn,sr); mean reactance (Xm); resonance frequency (fr) and impedance module at 4 Hz (|Zrs4Hz|). In the spirometry parameters, obstructive respiratory disease (ORD) with reduced FVC prevailed, with marked reduction in FEF25% - 75% in CF group (p <0.0001) compared to control. It was observed in plethysmography an elevation of RV, in the presence of normal TLC and elevated Rva and decreased SGva in the group with CF. Changes in the FOT occurred in the CF group compared to control: increased R0, Rm (p <0.0001) and fr (p <0.0002) related to obstruction of the airways; reduction of S (p <0.0006) and Xm (P <0.0001) associated with non-homogeneity of the respiratory system and reduction in the Cdyn, sr (p <0.0001) related to the pulmonary compliance. Increased module of the impedance at 4 Hz (| Zrs4Hz |) (representing total mechanical load of the respiratory system) resulting from the interaction of other changes in the FOT cited. The FOT parameters showed very good correlation with spirometry and moderated correlation with plethysmography. Rm was the only parameter that was not related to any of these techniques. Sensitivity and specificity of FOT in adults with CF was elevated, mainly for the reactive parameters, particularly, Xm (85.2% and 73.9%, respectively and area under the curve 0.86). / A fibrose cística (FC) é a doença autossômica recessiva mais comum na população branca que leva à redução na expectativa de vida. A doença pulmonar é a maior causa de morbidade e mortalidade. A relevância do presente estudo se dá diante de alguns fatores: aumento drástico da sobrevida média nos últimos 60 anos na FC, a fisiopatologia pulmonar não é bem compreendida, ausência de estudos reportados na literatura, até o momento, utilizando a técnica de oscilações forçadas (TOF) exclusivamente em adultos com FC. Assim sendo os objetivos deste estudo são: analisar as alterações da mecânica respiratória em adultos com FC através da espirometria, pletismografia e TOF; correlacionar os resultados da TOF aos espirométricos e pletismográficos e avaliar a sensibilidade e especificidade da TOF nestes indivíduos. É um estudo de corte transversal descritivo, no qual foram analisados dois grupos de indivíduos: controle (n=23) e FC (n=27). Os resultados foram expressos através média desvio-padrão. As técnicas funcionais respiratórias foram realizadas na seguinte sequência: TOF, espirometria, pletismografia. Na pletismografia foram avaliados os parâmetros: CPT (capacidade pulmonar total), CRF (capacidade residual funcional) e VR (volume residual), CRF/CPT e VR/CPT, resistência (Rva) e condutância específica das vias aéreas (SGva). Na espirometria: volume expiratório forçado no primeiro segundo (VEF1), capacidade vital forçada (CVF), fluxo expiratório entre 25% e 75% (FEF25%-75%) da CVF (FEF25%-75%) e razões VEF1/CVF (%) e FEF/CVF (%). Na TOF: propriedades resistivas do sistema respiratório- R0 (resistência no intercepto), Rm (resistência média) e S (inclinação da reta de resistência) e propriedades reativas: Cdin,sr (complacência dinâmica do sistema respiratório), Xm (reatância média), frequência de ressonância (fr); e o módulo da impedância em 4 Hz (׀Zrs4Hz׀). Na espirometria o distúrbio ventilatório obstrutivo (DVO) com CVF reduzida foi predominante, com marcante redução do FEF25%-75% no grupo FC (p<0,0001) em relação ao controle. Na pletismografia: destacou-se a elevação de VR, na presença de CPT normal e elevação da Rva e redução da SGva no grupo FC. Alterações da TOF ocorridas no grupo FC em relação ao controle: aumento de R0 e Rm (p<0,0001) e fr (p<0,0002), relacionados à obstrução das vias aéreas; redução de S (p<0,0006), Xm (p<0,0001) associadas à não-homogeneidade do sistema respiratório e Cdin,sr (p<0,0001), relacionada à redução da complacência pulmonar; aumento do módulo da impedância em 4 Hz (׀Zrs4Hz׀) (representando a carga mecânica total do sistema respiratório) resultante da interação das demais alterações da TOF citadas. Os parâmetros da TOF apresentaram correlações muito boas com a espirometria e moderadas com a pletismografia. Rm foi o único parâmetro que não se relacionou com nenhuma destas técnicas. A sensibilidade e especificidade da TOF em adultos com FC apresentaram valores elevados, sobretudo nos parâmetros reativos, em especial, Xm (85,2% e 73,9% respectivamente e área sob a curva de 0,86).
|
2 |
Condições mecânicas do sistema respiratório em adultos com fibrose cística: estudo pela espirometria, pletismografia e técnica de oscilações forçadas / Mechanics conditions of respiratory system in adults with systic bibrosis: study by spirometry, plethysmography and forced oscillation techniqueAdma do Nascimento Lima 23 June 2010 (has links)
Cystic fibrosis (CF) is an autosomal recessive disease more common in the white population, which leads to reduction in life expectancy. Pulmonary disease is the major cause of morbidity and mortality. The relevance of this study takes on a some factors: the drastic increase in median survival in the last 60 years in CF; the pulmonary pathophysiology remains not well understood; up to now there is no reported study using forced oscillation technique (FOT) exclusively in adults with CF. Thus the aims of this study are: to analyze the changes in respiratory mechanics in adults with CF by spirometry, plethysmography and FOT; correlate the results of FOT to the spirometric and plethysmographic data and evaluate the sensitivity and specificity of FOT in these individuals. This is a descriptive cross-sectional study enrolling two groups of individuals: control (n=23) and CF (n=27). The results were expressed by mean standard deviation. The techniques applied to evaluate the lung function were performed as follows: FOT, spirometry and plethysmography. The following parameters were evaluated by plethysmography: total lung capacity (TLC); functional residual capacity (FRC); residual volume (RV); FRC/TLC; RV/TLC; resistance airway (Rva) and specific airway conductance (SGva). On spirometry: first second forced expiratory volume (FEV1); forced vital capacity (FVC); forced expiratory flow between 25% and 75% of FVC (FEF25% - 75%) and the relations FEV1/ FVC (%) and FEF/FVC (%). In FOT: the resistance properties of the respiratory system - R0 (resistance at the intercept); medium resistance (Rm); slope of the linear resistance (S) and reactive properties: dynamic compliance of the respiratory system (Cdyn,sr); mean reactance (Xm); resonance frequency (fr) and impedance module at 4 Hz (|Zrs4Hz|). In the spirometry parameters, obstructive respiratory disease (ORD) with reduced FVC prevailed, with marked reduction in FEF25% - 75% in CF group (p <0.0001) compared to control. It was observed in plethysmography an elevation of RV, in the presence of normal TLC and elevated Rva and decreased SGva in the group with CF. Changes in the FOT occurred in the CF group compared to control: increased R0, Rm (p <0.0001) and fr (p <0.0002) related to obstruction of the airways; reduction of S (p <0.0006) and Xm (P <0.0001) associated with non-homogeneity of the respiratory system and reduction in the Cdyn, sr (p <0.0001) related to the pulmonary compliance. Increased module of the impedance at 4 Hz (| Zrs4Hz |) (representing total mechanical load of the respiratory system) resulting from the interaction of other changes in the FOT cited. The FOT parameters showed very good correlation with spirometry and moderated correlation with plethysmography. Rm was the only parameter that was not related to any of these techniques. Sensitivity and specificity of FOT in adults with CF was elevated, mainly for the reactive parameters, particularly, Xm (85.2% and 73.9%, respectively and area under the curve 0.86). / A fibrose cística (FC) é a doença autossômica recessiva mais comum na população branca que leva à redução na expectativa de vida. A doença pulmonar é a maior causa de morbidade e mortalidade. A relevância do presente estudo se dá diante de alguns fatores: aumento drástico da sobrevida média nos últimos 60 anos na FC, a fisiopatologia pulmonar não é bem compreendida, ausência de estudos reportados na literatura, até o momento, utilizando a técnica de oscilações forçadas (TOF) exclusivamente em adultos com FC. Assim sendo os objetivos deste estudo são: analisar as alterações da mecânica respiratória em adultos com FC através da espirometria, pletismografia e TOF; correlacionar os resultados da TOF aos espirométricos e pletismográficos e avaliar a sensibilidade e especificidade da TOF nestes indivíduos. É um estudo de corte transversal descritivo, no qual foram analisados dois grupos de indivíduos: controle (n=23) e FC (n=27). Os resultados foram expressos através média desvio-padrão. As técnicas funcionais respiratórias foram realizadas na seguinte sequência: TOF, espirometria, pletismografia. Na pletismografia foram avaliados os parâmetros: CPT (capacidade pulmonar total), CRF (capacidade residual funcional) e VR (volume residual), CRF/CPT e VR/CPT, resistência (Rva) e condutância específica das vias aéreas (SGva). Na espirometria: volume expiratório forçado no primeiro segundo (VEF1), capacidade vital forçada (CVF), fluxo expiratório entre 25% e 75% (FEF25%-75%) da CVF (FEF25%-75%) e razões VEF1/CVF (%) e FEF/CVF (%). Na TOF: propriedades resistivas do sistema respiratório- R0 (resistência no intercepto), Rm (resistência média) e S (inclinação da reta de resistência) e propriedades reativas: Cdin,sr (complacência dinâmica do sistema respiratório), Xm (reatância média), frequência de ressonância (fr); e o módulo da impedância em 4 Hz (׀Zrs4Hz׀). Na espirometria o distúrbio ventilatório obstrutivo (DVO) com CVF reduzida foi predominante, com marcante redução do FEF25%-75% no grupo FC (p<0,0001) em relação ao controle. Na pletismografia: destacou-se a elevação de VR, na presença de CPT normal e elevação da Rva e redução da SGva no grupo FC. Alterações da TOF ocorridas no grupo FC em relação ao controle: aumento de R0 e Rm (p<0,0001) e fr (p<0,0002), relacionados à obstrução das vias aéreas; redução de S (p<0,0006), Xm (p<0,0001) associadas à não-homogeneidade do sistema respiratório e Cdin,sr (p<0,0001), relacionada à redução da complacência pulmonar; aumento do módulo da impedância em 4 Hz (׀Zrs4Hz׀) (representando a carga mecânica total do sistema respiratório) resultante da interação das demais alterações da TOF citadas. Os parâmetros da TOF apresentaram correlações muito boas com a espirometria e moderadas com a pletismografia. Rm foi o único parâmetro que não se relacionou com nenhuma destas técnicas. A sensibilidade e especificidade da TOF em adultos com FC apresentaram valores elevados, sobretudo nos parâmetros reativos, em especial, Xm (85,2% e 73,9% respectivamente e área sob a curva de 0,86).
|
3 |
O uso da Técnica de Oscilações Forçadas na análise da mecânica ventilatória de indivíduos portadores de silicose classificados em diferentes graus de obstrução / Using the forced oscillation technique in the analysis of mechanical ventilation in individuals with silicosis classified into different degrees of obstructionPaula Morisco de Sá Peleteiro 30 March 2011 (has links)
O termo silicose refere-se ao processo de fibrose pulmonar causado pela inalação de poeira contendo sílica. É uma doença ocupacional, incurável, que se inicia nas vias aéreas distais e pode progredir independente do término da
exposição. Os testes de função pulmonar, apesar de não serem utilizados como ferramenta diagnóstica para silicose, são amplamente empregados para acompanhar longitudinalmente esses indivíduos. Estudos recentes sugerem que a Técnicas de Oscilações Forçadas (FOT) pode ser aplicada para detecção de alterações pulmonares precoces em indivíduos com silicose. Contudo, existem poucos estudos descrevendo as alterações de mecância respiratória associada com a silicose através da FOT. Neste contexto, os objetivos deste estudo são: (1) analisar as alterações de mecânica respiratória de indivíduos portadores de silicose com diferentes graus de obstrução e (2) avaliar a capacidade da FOT em detectar alterações na função pulmonar decorrentes da silicose. Trata-se de um estudo
transversal controlado com avaliação de casos prevalentes, tendo como unidade de avaliação o indivíduo. Os exames realizados incluíram medidas de espirometria e FOT. Foi selecionado um total de 67 indivíduos, 46 portadores de silicose e 21 sadios, caracterizando o grupo controle. Os indivíduos com diagnóstico de silicose foram divididos em três grupos classificados de acordo com o nível de obstrução
sugerido pela espirometria. Essa classificação resultou em três categorias: Indivíduos normais ao exame espirométrico (NE), n= 12; com distúrbio ventilatório obstrutivo leve (DVOL), n=22; com distúrbio ventilatório obstrutivo moderado ou acentuado (DVOMA), n= 12. Todos os indivíduos realizaram exames da FOT para análise das propriedades resistivas e reativas do sistema respiratório.
Posteriormente aos exames da FOT os indivíduos foram submetidos à espirometria. Considerando os grupos divididos a partir da espirometria, os parâmetros resistivos e reativos e a impedância do sistema respiratório em 4Hz (Z4Hz) se modificaram significativamente com a progressão da distúrbio obstrutivo. Na análise do poder diagnóstico da FOT os parâmetros R0, Rm, Rsr4 e |Z4Hz| mostraram-se precisos
para identificar as modificações de mecânica respiratória em pacientes com silicose apresentando distúrbio ventilatório obstrutivo leve. Para distúrbio ventilatório obstrutivo moderado e acentuado todos os parâmetros analisados apresentaram habilidade para identificar essas alterações. Na análise entre o grupo controle e normal ao exame, nenhum parâmetro da FOT apresentou valor de acurácia adequado para uso clínico. Esses resultados são coerentes com as alterações fisiopatológicas relacionadas à silicose, confirmando o potencial da FOT na avaliação das modificações de mecânica respiratória em doentes com silicose. / The term silicosis is the name given to the pulmonary fibrosis caused by inhalation of dust containing crystalline silica. Is a typical occupational disease,
chronic, incurable, starting in the peripheral airways and that can progress independently of the end of exposure. The pulmonary function tests, although not used as a diagnostic tool for silicosis, are widely employed to follow these individuals. Recent works suggests that the Forced Oscilation Technique (FOT) may be applied in the detection of early respiratory changes in silicosis. However, few studies have been analyzing the changes on respiratory mechanics associated with silicosis through the FOT. In this context, the aims of this study were (1) to analyze changes respiratory mechanics in subjects with silicosis with different degrees of obstruction by FOT, and (2) to evaluate the potential of the FOT to detect alterations in the lung function resulting from silicosis. This is a sectional study evaluation of prevalent cases, with the evaluation unit the individual. The examinations included measurement of FOT and spirometry. Sixty-seven volunteers were analyzed: 21 healthy subjects and 46 with silicosis. Spirometry was used to classify airway
obstruction in the silicosis groups. This classification resulted in three categories: normal spirometric exam (n = 12); mild obstruction (n = 22); moderate or severe
obstruction (n = 12.). All subjects performed FOT exam for the analysis of resistive and reactive properties of the respiratory system. The order of the examinations was FOT, followed by spirometry. Considering the groups classified according to the spirometry, the resistive and reactive the parameters and the impedance of the respiratory system at 4Hz (|Z4Hz|), have changed significantly with the progression of obstructive. The analysis of the diagnostic power of FOT parameters R0, Rm, and Rsr4 |Z4Hz| showed to be accurate to identify the changes of respiratory mechanics in silicosis patients with mild obstructive lung disease. To the moderate and severe obstructions, all the parameters analyzed showed adequate to identify these changes. In the analysis between the control and normal exam, no parameters of the FOT showed adequate measure to use to correctly identify these subjects. The FOT
parameters adequately described the pathophysiological changes associated with silicosis and presented adequate accuracy for clinical use, indicating that this technique can be helpful in the evaluation respiratory mechanics in this disease.
|
4 |
Análise das alterações decorrentes do envelhecimento na mecânica respiratória pela técnica de oscilações forçadas / Analysis of the changes in the respiratory mechanics dued to aage by the Forced Oscilation TechniqueCaio Vinícius Villalón Tramont 30 June 2009 (has links)
O crescimento do percentual de idosos na população ocorre mundialmente tornando necessário conhecer o impacto do processo de envelhecimento, neste contexto, do sistema respiratório. O desconhecimento do impacto do envelhecimento
associado a diferentes graus de exposição a poluentes e a presença de comorbidade(s) dificulta a diagnose das pneumopatias acarretando aos idosos piora da qualidade de
vida. São vantagens da Técnica de Oscilações Forçadas (FOT): alto potencial de aplicação em idosos, fácil realização, análise detalhada da mecânica respiratória, desempenho de papel complementar, bem como de alternativa na impossibilidade de
realização dos exames tradicionais. Foi realizado um estudo experimental comparativo que objetivou investigar o impacto do envelhecimento no sistema respiratório pela FOT e pela espirometria entre grupos de diferentes faixas etárias, sendo a idade a variável independente e as variáveis dependentes, os parâmetros oscilométricos resistência em regime contínuo (R0) e das vias aéreas centrais (Rm), inclinação da resistência (S),
frequência de ressonância (fr), reatância média (Xm), complacência dinâmica (Cdin,sr) e os parâmetros espirométricos (VEF1, CVF, VEF1/CVF e FEF/CVF). Foram realizados entrevista, exame clínico, radiografia torácica, avaliação da mecânica respiratória pela FOT e da função pulmonar pela espirometria. 255 indivíduos com idades entre 20 e 86 anos foram entrevistados. Destes, 175 foram excluídos, restando os 80 voluntários analisados, que foram divididos em 6 grupos de acordo com a faixa etária (A: 20 a 29 anos; B: 30 a 39 anos; C: 40 a 49 anos; D: 50 a 59 anos; E: 60 a 69 anos; F: 70 anos ou
mais). Foram utilizados os testes de Shapiro-Wilkins, na avaliação da normalidade dos dados biométricos em cada grupo, Oneway ANOVA, na comparação entre os grupos, e Tukey HSD na comparação entre as classes subjacentes. A análise da associação entre duas variáveis foi realizada inicialmente pela regressão univariada entre os parâmetros oscilométricos, a idade e a altura. A regressão múltipla entre os parâmetros
oscilométricos, idade e altura foi realizada em conjunto. Foi realizada a análise de confundimento ou modificação de efeito sobre o parâmetro altura na relação entre a idade e os parâmetros oscilométricos. A correção pelo fator altura foi realizada quando sua análise apresentava fator de confundimento. Quanto aos parâmetros resistivos, não foram observadas alterações em R0 e Rm com o envelhecimento enquanto que o declínio observado em S é discreto e não-significativo. Em relação aos parâmetros reativos,
verificouse que Cdin,sr e Xm diminuem enquanto que fr aumenta com o processo de envelhecimento. Todas estas alterações são significativas. Todavia, a diminuição da Cdin,sr não apresenta relação com a idade e sim com a altura, que constituiu modificação do efeito. Nos demais parâmetros oscilométricos, a altura constituiu fator de confundimento. Quanto à espirometria, observou-se declínio significativo do VEF1, do
VEF1/CVF e da CVF. O índice FEF/CVF apresentou declínio nãosignificativo. Concluindo, a resistência do sistema respiratório e a complacência dinâmica não se modificam enquanto a homogeneidade do sistema respiratório diminui com o processo de envelhecimento. / The increase in the elderly percentage in the population occurs worldwide. To know the impact of the aging process, in this context, on the respiratory system, is crucial. The unawareness of the impact of aging, with different exposure degrees to
pollution and the presence of commorbities introduces difficulty in the pneumopathies diagnosis make worsen the elderlys quality of life. The Forced Oscillation Technique (FOT) has as advantages a high application potential in elderly people, detailed analysis of the respiratory mechanics, plays complementary role and alternative in the impossibility to perform the traditional exams, as well. A comparative experimental study was done with the purpose of analyze the impact of aging in the respiratory system by FOT and spirometry between groups of different ages. Age is the independent variable and the dependent variables are the oscillometric parameters continuum regime resistance (R0), central airways resistance (Rm), slope of resistance (S), resonant frequency (fr), average reactance (Xm), dynamic compliance (Cdin,sr) and the spirometry parameters (FEV1, FVC, FEV1/CVF and FEF/FVC). Interviews, clinical examination,
thoracic roentgenograms, mensuration of the respiratory mechanics by FOT and of the pulmonary function by spirometry were performed. 255 individuals aged from 20 to 86 years were interviewed. From these, 175 were excluded and the 80 remaining volunteers were analyzed and divided into six groups according to age (A: 20-29 years old; B: 30-39 years old; C: 40-49 years old; D: 50-59 years old; E: 60-69 years old; F: 70 or more years old). The Shapiro-Wilkins test was used in the analysis of the normality of the biometric data in each group. Oneway ANOVA was used in the comparison between groups and the Tukey HSD test was used in the comparison between the underlying classes. The analysis of the association between two variables was done initially between the oscilometric parameters, age and height. Multiple regressions between
oscilometric parameters, age and height was performed in conjunction. Confounding analysis or effect modification over height and oscilometric parameters was done. The correction by the height factor was done when its analysis presented confounding factor. There were not changes in the resistive parameters R0 and Rm with age while the decrease seen in S is slight and not significant. In the reactive parameters, it was found that Cdin,sr and Xm decrease while fr increases with the aging process. All of these changes are significant. However, the decrease in Cdin,sr is not related to the aging process but with height, which was a confounding factor. It was found that the spirometric parameters FEV1, FVC and CVF presented a significant decrease and the index FEF/CVF presented a not significant decrease. Concluding, the resistance and the
dynamic compliance of the respiratory system do not change while the homogeneity of the respiratory system decreases with the aging process.
|
5 |
Análise das alterações decorrentes do envelhecimento na mecânica respiratória pela técnica de oscilações forçadas / Analysis of the changes in the respiratory mechanics dued to aage by the Forced Oscilation TechniqueCaio Vinícius Villalón Tramont 30 June 2009 (has links)
O crescimento do percentual de idosos na população ocorre mundialmente tornando necessário conhecer o impacto do processo de envelhecimento, neste contexto, do sistema respiratório. O desconhecimento do impacto do envelhecimento
associado a diferentes graus de exposição a poluentes e a presença de comorbidade(s) dificulta a diagnose das pneumopatias acarretando aos idosos piora da qualidade de
vida. São vantagens da Técnica de Oscilações Forçadas (FOT): alto potencial de aplicação em idosos, fácil realização, análise detalhada da mecânica respiratória, desempenho de papel complementar, bem como de alternativa na impossibilidade de
realização dos exames tradicionais. Foi realizado um estudo experimental comparativo que objetivou investigar o impacto do envelhecimento no sistema respiratório pela FOT e pela espirometria entre grupos de diferentes faixas etárias, sendo a idade a variável independente e as variáveis dependentes, os parâmetros oscilométricos resistência em regime contínuo (R0) e das vias aéreas centrais (Rm), inclinação da resistência (S),
frequência de ressonância (fr), reatância média (Xm), complacência dinâmica (Cdin,sr) e os parâmetros espirométricos (VEF1, CVF, VEF1/CVF e FEF/CVF). Foram realizados entrevista, exame clínico, radiografia torácica, avaliação da mecânica respiratória pela FOT e da função pulmonar pela espirometria. 255 indivíduos com idades entre 20 e 86 anos foram entrevistados. Destes, 175 foram excluídos, restando os 80 voluntários analisados, que foram divididos em 6 grupos de acordo com a faixa etária (A: 20 a 29 anos; B: 30 a 39 anos; C: 40 a 49 anos; D: 50 a 59 anos; E: 60 a 69 anos; F: 70 anos ou
mais). Foram utilizados os testes de Shapiro-Wilkins, na avaliação da normalidade dos dados biométricos em cada grupo, Oneway ANOVA, na comparação entre os grupos, e Tukey HSD na comparação entre as classes subjacentes. A análise da associação entre duas variáveis foi realizada inicialmente pela regressão univariada entre os parâmetros oscilométricos, a idade e a altura. A regressão múltipla entre os parâmetros
oscilométricos, idade e altura foi realizada em conjunto. Foi realizada a análise de confundimento ou modificação de efeito sobre o parâmetro altura na relação entre a idade e os parâmetros oscilométricos. A correção pelo fator altura foi realizada quando sua análise apresentava fator de confundimento. Quanto aos parâmetros resistivos, não foram observadas alterações em R0 e Rm com o envelhecimento enquanto que o declínio observado em S é discreto e não-significativo. Em relação aos parâmetros reativos,
verificouse que Cdin,sr e Xm diminuem enquanto que fr aumenta com o processo de envelhecimento. Todas estas alterações são significativas. Todavia, a diminuição da Cdin,sr não apresenta relação com a idade e sim com a altura, que constituiu modificação do efeito. Nos demais parâmetros oscilométricos, a altura constituiu fator de confundimento. Quanto à espirometria, observou-se declínio significativo do VEF1, do
VEF1/CVF e da CVF. O índice FEF/CVF apresentou declínio nãosignificativo. Concluindo, a resistência do sistema respiratório e a complacência dinâmica não se modificam enquanto a homogeneidade do sistema respiratório diminui com o processo de envelhecimento. / The increase in the elderly percentage in the population occurs worldwide. To know the impact of the aging process, in this context, on the respiratory system, is crucial. The unawareness of the impact of aging, with different exposure degrees to
pollution and the presence of commorbities introduces difficulty in the pneumopathies diagnosis make worsen the elderlys quality of life. The Forced Oscillation Technique (FOT) has as advantages a high application potential in elderly people, detailed analysis of the respiratory mechanics, plays complementary role and alternative in the impossibility to perform the traditional exams, as well. A comparative experimental study was done with the purpose of analyze the impact of aging in the respiratory system by FOT and spirometry between groups of different ages. Age is the independent variable and the dependent variables are the oscillometric parameters continuum regime resistance (R0), central airways resistance (Rm), slope of resistance (S), resonant frequency (fr), average reactance (Xm), dynamic compliance (Cdin,sr) and the spirometry parameters (FEV1, FVC, FEV1/CVF and FEF/FVC). Interviews, clinical examination,
thoracic roentgenograms, mensuration of the respiratory mechanics by FOT and of the pulmonary function by spirometry were performed. 255 individuals aged from 20 to 86 years were interviewed. From these, 175 were excluded and the 80 remaining volunteers were analyzed and divided into six groups according to age (A: 20-29 years old; B: 30-39 years old; C: 40-49 years old; D: 50-59 years old; E: 60-69 years old; F: 70 or more years old). The Shapiro-Wilkins test was used in the analysis of the normality of the biometric data in each group. Oneway ANOVA was used in the comparison between groups and the Tukey HSD test was used in the comparison between the underlying classes. The analysis of the association between two variables was done initially between the oscilometric parameters, age and height. Multiple regressions between
oscilometric parameters, age and height was performed in conjunction. Confounding analysis or effect modification over height and oscilometric parameters was done. The correction by the height factor was done when its analysis presented confounding factor. There were not changes in the resistive parameters R0 and Rm with age while the decrease seen in S is slight and not significant. In the reactive parameters, it was found that Cdin,sr and Xm decrease while fr increases with the aging process. All of these changes are significant. However, the decrease in Cdin,sr is not related to the aging process but with height, which was a confounding factor. It was found that the spirometric parameters FEV1, FVC and CVF presented a significant decrease and the index FEF/CVF presented a not significant decrease. Concluding, the resistance and the
dynamic compliance of the respiratory system do not change while the homogeneity of the respiratory system decreases with the aging process.
|
6 |
O uso da Técnica de Oscilações Forçadas na análise da mecânica ventilatória de indivíduos portadores de silicose classificados em diferentes graus de obstrução / Using the forced oscillation technique in the analysis of mechanical ventilation in individuals with silicosis classified into different degrees of obstructionPaula Morisco de Sá Peleteiro 30 March 2011 (has links)
O termo silicose refere-se ao processo de fibrose pulmonar causado pela inalação de poeira contendo sílica. É uma doença ocupacional, incurável, que se inicia nas vias aéreas distais e pode progredir independente do término da
exposição. Os testes de função pulmonar, apesar de não serem utilizados como ferramenta diagnóstica para silicose, são amplamente empregados para acompanhar longitudinalmente esses indivíduos. Estudos recentes sugerem que a Técnicas de Oscilações Forçadas (FOT) pode ser aplicada para detecção de alterações pulmonares precoces em indivíduos com silicose. Contudo, existem poucos estudos descrevendo as alterações de mecância respiratória associada com a silicose através da FOT. Neste contexto, os objetivos deste estudo são: (1) analisar as alterações de mecânica respiratória de indivíduos portadores de silicose com diferentes graus de obstrução e (2) avaliar a capacidade da FOT em detectar alterações na função pulmonar decorrentes da silicose. Trata-se de um estudo
transversal controlado com avaliação de casos prevalentes, tendo como unidade de avaliação o indivíduo. Os exames realizados incluíram medidas de espirometria e FOT. Foi selecionado um total de 67 indivíduos, 46 portadores de silicose e 21 sadios, caracterizando o grupo controle. Os indivíduos com diagnóstico de silicose foram divididos em três grupos classificados de acordo com o nível de obstrução
sugerido pela espirometria. Essa classificação resultou em três categorias: Indivíduos normais ao exame espirométrico (NE), n= 12; com distúrbio ventilatório obstrutivo leve (DVOL), n=22; com distúrbio ventilatório obstrutivo moderado ou acentuado (DVOMA), n= 12. Todos os indivíduos realizaram exames da FOT para análise das propriedades resistivas e reativas do sistema respiratório.
Posteriormente aos exames da FOT os indivíduos foram submetidos à espirometria. Considerando os grupos divididos a partir da espirometria, os parâmetros resistivos e reativos e a impedância do sistema respiratório em 4Hz (Z4Hz) se modificaram significativamente com a progressão da distúrbio obstrutivo. Na análise do poder diagnóstico da FOT os parâmetros R0, Rm, Rsr4 e |Z4Hz| mostraram-se precisos
para identificar as modificações de mecânica respiratória em pacientes com silicose apresentando distúrbio ventilatório obstrutivo leve. Para distúrbio ventilatório obstrutivo moderado e acentuado todos os parâmetros analisados apresentaram habilidade para identificar essas alterações. Na análise entre o grupo controle e normal ao exame, nenhum parâmetro da FOT apresentou valor de acurácia adequado para uso clínico. Esses resultados são coerentes com as alterações fisiopatológicas relacionadas à silicose, confirmando o potencial da FOT na avaliação das modificações de mecânica respiratória em doentes com silicose. / The term silicosis is the name given to the pulmonary fibrosis caused by inhalation of dust containing crystalline silica. Is a typical occupational disease,
chronic, incurable, starting in the peripheral airways and that can progress independently of the end of exposure. The pulmonary function tests, although not used as a diagnostic tool for silicosis, are widely employed to follow these individuals. Recent works suggests that the Forced Oscilation Technique (FOT) may be applied in the detection of early respiratory changes in silicosis. However, few studies have been analyzing the changes on respiratory mechanics associated with silicosis through the FOT. In this context, the aims of this study were (1) to analyze changes respiratory mechanics in subjects with silicosis with different degrees of obstruction by FOT, and (2) to evaluate the potential of the FOT to detect alterations in the lung function resulting from silicosis. This is a sectional study evaluation of prevalent cases, with the evaluation unit the individual. The examinations included measurement of FOT and spirometry. Sixty-seven volunteers were analyzed: 21 healthy subjects and 46 with silicosis. Spirometry was used to classify airway
obstruction in the silicosis groups. This classification resulted in three categories: normal spirometric exam (n = 12); mild obstruction (n = 22); moderate or severe
obstruction (n = 12.). All subjects performed FOT exam for the analysis of resistive and reactive properties of the respiratory system. The order of the examinations was FOT, followed by spirometry. Considering the groups classified according to the spirometry, the resistive and reactive the parameters and the impedance of the respiratory system at 4Hz (|Z4Hz|), have changed significantly with the progression of obstructive. The analysis of the diagnostic power of FOT parameters R0, Rm, and Rsr4 |Z4Hz| showed to be accurate to identify the changes of respiratory mechanics in silicosis patients with mild obstructive lung disease. To the moderate and severe obstructions, all the parameters analyzed showed adequate to identify these changes. In the analysis between the control and normal exam, no parameters of the FOT showed adequate measure to use to correctly identify these subjects. The FOT
parameters adequately described the pathophysiological changes associated with silicosis and presented adequate accuracy for clinical use, indicating that this technique can be helpful in the evaluation respiratory mechanics in this disease.
|
7 |
Análise das alterações de mecânica respiratória e da resposta broncodilatadora em crianças asmáticas por meio da Técnica de oscilações Forçadas / Analysis of changes in respiratory machanics and bronchodilator response in asthmatic children by Forced Oscilations TechniqueGeorgia Alencar Franco de Souza 20 April 2010 (has links)
O aprofundamento de nosso conhecimento acerca das alterações da mecânica respiratória e da resposta ao uso do broncodilatador em crianças com asma pode contribuir para o melhor entendimento desta doença. A técnica de oscilações forçadas (FOT) apresenta elevado potencial neste sentido, pois permite uma avaliação detalhada da mecânica respiratória de crianças asmáticas. Desta maneira, os objetivos deste estudo são: (1) aprofundar nosso conhecimento sobre as alterações de mecânica respiratória em crianças asmáticas; (2) investigar o potencial de utilização clínica da FOT e (3) analisar as alterações de mecânica respiratória decorrentes da resposta broncodilatadora em crianças asmáticas. No presente estudo foram analisadas 93 crianças, separadas em grupo controle (n=31) e grupo de crianças asmáticas divididas de acordo com o grau de obstrução ao fluxo aéreo determinado pela espirometria em: normal ao exame espirométrico (n=31) e com distúrbio ventilatório obstrutivo leve (n=31). Pela FOT foram analisados os parâmetros relacionados às propriedades resistivas do sistema respiratório R0 (resistência no intercepto), Rm (resistência média) e S (inclinação da reta de resistência). R0 e Rm aumentaram com a obstrução ao fluxo aéreo (p<0,002 e p<0,02, respectivamente) e S apresentou redução (p<0,0007) caracterizando, este último, aumento da não-homogeneidade do sistema respiratório. Observou- se uma redução nos parâmetros relacionados às propriedades reativas do sistema respiratório, Cdin,sr (complacência dinâmica, p<0,03) e Xm (reatância média, p<0,02) com o aumento da obstrução. Também foi analisado o módulo da impedância em 4 Hz (׀Zrs4Hz׀), parâmetro relacionado com a carga mecânica total no sistema respiratório, que mostrou- se aumentado com a obstrução(p<0,001). Na análise do desempenho diagnóstico, os parâmetros R0, Rm, Cdin,sr e ׀Zrs4Hz׀ apresentaram área sob a Curva (AUC), sensibilidade (Se) e especificidade (Sp) adequados ao uso clínico no grupo com distúrbio ventilatório obstrutivo leve. Estes valores foram mais elevados do que no grupo de crianças asmáticas normais ao exame espirometrico, o que está relacionado com as maiores alterações no grupo com obstrutrução leve. A resposta broncodilatadora foi estudada observando- se as diferenças dentro do mesmo grupo de crianças e mensurando as alterações em cada grupo antes e após o uso do broncodilatador. Os parâmetros relacionados às propriedades resistivas, R0, Rm e S apresentaram melhora significativa com redução das resistências no grupo controle (p<0,00001, p<0,0003 e 0,00001), normal ao exame espirometrico (p<0,000002, p<0,00008 e 0,0006) e grupo com distúrbio ventilatório obstrutivo leve (p<0,0001, p<0,0007 e 0,000001). Estas alterações ocorreram no grupo controle e nos grupos de crianças asmáticas. Crs,din e Xm também apresentaram alterações significativas em todos os grupos estudados: no grupo controle (p<0,0001, p<0,00001), normal ao exame (p<0,00006, p<0,00001) e no grupo com distúrbio ventilatório obstrutivo leve (p<0,0001, p<0,00001), fato também observado na análise de ׀Zrs4Hz׀ no grupo controle (p<0,00001), normal ao exame (p<0,00001) e grupo com distúrbio ventilatório obstrutivo leve (p<0, 00001). Concluímos que a asma introduz alterações nos parâmetros resistivos e reativos do sistema respiratório com o aumento do grau de obstrução ao fluxo aéreo. Essas alterações foram identificadas nas crianças com obstrução leve. A FOT detectou as alterações ocorridas após a utilização da medicação broncodilatadora. Estes resultados indicam que a FOT pode ser um exame sensível para avaliar as alterações fisiopatológicas decorrentes da asma em crianças. / The increase of our knowledge about changes in respiratory mechanics and response to bronchodilator use in asthmatic children may contribute to a better understanding of this disease. The forced oscillation technique (FOT) has high potential in this sense, since it allows a detailed assessment of respiratory mechanics in asthmatic children. Thus, the objectives of this study are: (1) increase our understanding of the changes in respiratory mechanics of asthma in children, (2) investigate the clinical potential of FOT and (3) analyze the changes in respiratory mechanics resulting from bronchodilator response in asthmatic children.
The present study examined 93 children, separated in the control group (n=31) and the asthmatic group divided according to the degree of airflow obstruction determined by spirometry in normal spirometry results (n=31) and with mild airway obstruction (n=31). Using the FOT we analyzed parameters related to the resistance of the respiratory system R0 (intercept resistance), Rm (resistance average) and S (slope of the resistance). R0 and Rm increased with airflow obstruction (p<0.002 and p<0.02, respectively) and S decreased (p<0.0007), indicating increased respiratory system non-homogeneity. There was a reduction in parameters related to the reactive properties of the respiratory system, Cst,sr (dynamic compliance, p<0.03) and Xm (reactance average, p<0,001) with increasing obstruction. The module of the respiratory system impedance at 4 Hz (| Zrs4Hz |) was also studied. This parameter is related to the total mechanical load on the respiratory system, and increased significantly with obstruction (p<0,001). Analyzing the diagnostic performance of FOT parameters, R0, Rm, Cst,sr and |Zrs4Hz| presented adequate values for clinical use in the identification of mild airway obstruction (AUC>0.7). These values were higher than that observed in the identification of the normal to the spirometric exam group, which may be related to the higher modifications in the group of children with mild airway obstruction. The bronchodilator response was studied by observing the differences within the same group of children, measuring the changes in each group before and after bronchodilator use. The parameters related to the resistance, R0, Rm and S showed significant improvement indicating reduced resistance in control group (p<0.00001,p<0.0003 e 0.00001), normal spirometry results (p<0.000002, p<0.00008 e 0.0006) and with mild airway obstruction (p<0.0001, p<0.0007 e 0.000001). These changes occurred in the control group and groups of children with asthma. Crs,din and Xm also showed significant changes in all groups studied in control group p<0.0001, p<0.00001), normal spirometry results (p<0.00006, p<0.00001) and with mild airway obstruction (p<0.0001, p<0.00001), a fact also observed in the analysis of | Zrs4Hz |, with showed a significant decrease in control group (p<0.00001), normal spirometry results(p<0.00001) and with mild airway obstruction (p<0.00001). We conclude that the increase of the degree of airflow obstruction in asthmatic children introduces increases in the resistance of the respiratory system, reductions in the dynamic compliance, reduction in homogeneity, as well as increase in the total respiratory system mechanical load. The FOT is able to detect respiratory changes in patients with mild airway obstruction. The use of bronchodilator medication introduces changes in asthmatic children, as well as in normal children. The results of the present study indicate that the FOT can be a sensitive test to evaluate the changes associated with asthma in children.
|
8 |
Análise das alterações de mecânica respiratória e da resposta broncodilatadora em crianças asmáticas por meio da Técnica de oscilações Forçadas / Analysis of changes in respiratory machanics and bronchodilator response in asthmatic children by Forced Oscilations TechniqueGeorgia Alencar Franco de Souza 20 April 2010 (has links)
O aprofundamento de nosso conhecimento acerca das alterações da mecânica respiratória e da resposta ao uso do broncodilatador em crianças com asma pode contribuir para o melhor entendimento desta doença. A técnica de oscilações forçadas (FOT) apresenta elevado potencial neste sentido, pois permite uma avaliação detalhada da mecânica respiratória de crianças asmáticas. Desta maneira, os objetivos deste estudo são: (1) aprofundar nosso conhecimento sobre as alterações de mecânica respiratória em crianças asmáticas; (2) investigar o potencial de utilização clínica da FOT e (3) analisar as alterações de mecânica respiratória decorrentes da resposta broncodilatadora em crianças asmáticas. No presente estudo foram analisadas 93 crianças, separadas em grupo controle (n=31) e grupo de crianças asmáticas divididas de acordo com o grau de obstrução ao fluxo aéreo determinado pela espirometria em: normal ao exame espirométrico (n=31) e com distúrbio ventilatório obstrutivo leve (n=31). Pela FOT foram analisados os parâmetros relacionados às propriedades resistivas do sistema respiratório R0 (resistência no intercepto), Rm (resistência média) e S (inclinação da reta de resistência). R0 e Rm aumentaram com a obstrução ao fluxo aéreo (p<0,002 e p<0,02, respectivamente) e S apresentou redução (p<0,0007) caracterizando, este último, aumento da não-homogeneidade do sistema respiratório. Observou- se uma redução nos parâmetros relacionados às propriedades reativas do sistema respiratório, Cdin,sr (complacência dinâmica, p<0,03) e Xm (reatância média, p<0,02) com o aumento da obstrução. Também foi analisado o módulo da impedância em 4 Hz (׀Zrs4Hz׀), parâmetro relacionado com a carga mecânica total no sistema respiratório, que mostrou- se aumentado com a obstrução(p<0,001). Na análise do desempenho diagnóstico, os parâmetros R0, Rm, Cdin,sr e ׀Zrs4Hz׀ apresentaram área sob a Curva (AUC), sensibilidade (Se) e especificidade (Sp) adequados ao uso clínico no grupo com distúrbio ventilatório obstrutivo leve. Estes valores foram mais elevados do que no grupo de crianças asmáticas normais ao exame espirometrico, o que está relacionado com as maiores alterações no grupo com obstrutrução leve. A resposta broncodilatadora foi estudada observando- se as diferenças dentro do mesmo grupo de crianças e mensurando as alterações em cada grupo antes e após o uso do broncodilatador. Os parâmetros relacionados às propriedades resistivas, R0, Rm e S apresentaram melhora significativa com redução das resistências no grupo controle (p<0,00001, p<0,0003 e 0,00001), normal ao exame espirometrico (p<0,000002, p<0,00008 e 0,0006) e grupo com distúrbio ventilatório obstrutivo leve (p<0,0001, p<0,0007 e 0,000001). Estas alterações ocorreram no grupo controle e nos grupos de crianças asmáticas. Crs,din e Xm também apresentaram alterações significativas em todos os grupos estudados: no grupo controle (p<0,0001, p<0,00001), normal ao exame (p<0,00006, p<0,00001) e no grupo com distúrbio ventilatório obstrutivo leve (p<0,0001, p<0,00001), fato também observado na análise de ׀Zrs4Hz׀ no grupo controle (p<0,00001), normal ao exame (p<0,00001) e grupo com distúrbio ventilatório obstrutivo leve (p<0, 00001). Concluímos que a asma introduz alterações nos parâmetros resistivos e reativos do sistema respiratório com o aumento do grau de obstrução ao fluxo aéreo. Essas alterações foram identificadas nas crianças com obstrução leve. A FOT detectou as alterações ocorridas após a utilização da medicação broncodilatadora. Estes resultados indicam que a FOT pode ser um exame sensível para avaliar as alterações fisiopatológicas decorrentes da asma em crianças. / The increase of our knowledge about changes in respiratory mechanics and response to bronchodilator use in asthmatic children may contribute to a better understanding of this disease. The forced oscillation technique (FOT) has high potential in this sense, since it allows a detailed assessment of respiratory mechanics in asthmatic children. Thus, the objectives of this study are: (1) increase our understanding of the changes in respiratory mechanics of asthma in children, (2) investigate the clinical potential of FOT and (3) analyze the changes in respiratory mechanics resulting from bronchodilator response in asthmatic children.
The present study examined 93 children, separated in the control group (n=31) and the asthmatic group divided according to the degree of airflow obstruction determined by spirometry in normal spirometry results (n=31) and with mild airway obstruction (n=31). Using the FOT we analyzed parameters related to the resistance of the respiratory system R0 (intercept resistance), Rm (resistance average) and S (slope of the resistance). R0 and Rm increased with airflow obstruction (p<0.002 and p<0.02, respectively) and S decreased (p<0.0007), indicating increased respiratory system non-homogeneity. There was a reduction in parameters related to the reactive properties of the respiratory system, Cst,sr (dynamic compliance, p<0.03) and Xm (reactance average, p<0,001) with increasing obstruction. The module of the respiratory system impedance at 4 Hz (| Zrs4Hz |) was also studied. This parameter is related to the total mechanical load on the respiratory system, and increased significantly with obstruction (p<0,001). Analyzing the diagnostic performance of FOT parameters, R0, Rm, Cst,sr and |Zrs4Hz| presented adequate values for clinical use in the identification of mild airway obstruction (AUC>0.7). These values were higher than that observed in the identification of the normal to the spirometric exam group, which may be related to the higher modifications in the group of children with mild airway obstruction. The bronchodilator response was studied by observing the differences within the same group of children, measuring the changes in each group before and after bronchodilator use. The parameters related to the resistance, R0, Rm and S showed significant improvement indicating reduced resistance in control group (p<0.00001,p<0.0003 e 0.00001), normal spirometry results (p<0.000002, p<0.00008 e 0.0006) and with mild airway obstruction (p<0.0001, p<0.0007 e 0.000001). These changes occurred in the control group and groups of children with asthma. Crs,din and Xm also showed significant changes in all groups studied in control group p<0.0001, p<0.00001), normal spirometry results (p<0.00006, p<0.00001) and with mild airway obstruction (p<0.0001, p<0.00001), a fact also observed in the analysis of | Zrs4Hz |, with showed a significant decrease in control group (p<0.00001), normal spirometry results(p<0.00001) and with mild airway obstruction (p<0.00001). We conclude that the increase of the degree of airflow obstruction in asthmatic children introduces increases in the resistance of the respiratory system, reductions in the dynamic compliance, reduction in homogeneity, as well as increase in the total respiratory system mechanical load. The FOT is able to detect respiratory changes in patients with mild airway obstruction. The use of bronchodilator medication introduces changes in asthmatic children, as well as in normal children. The results of the present study indicate that the FOT can be a sensitive test to evaluate the changes associated with asthma in children.
|
9 |
Impedância respiratória de entrada: comparação entre os métodos convencional e de wavetube. / Input respiratory impedance: comparison between conventional and wavetube methods.Mori, Vitor 26 August 2015 (has links)
A impedância respiratória de entrada pode ser obtida pela Técnica das Oscilações Forçadas (FOT) através de dois métodos diferentes: convencional e de wavetube. Nessa dissertação, primeiramente realizamos uma revisão bibliográfica com enfoque nos assuntos de interesse para esse trabalho, como definições e modelagem de impedância, descrições e bases teóricas para a realização dos dois métodos e descrição dos equipamentos utilizados por cada um dos métodos. A partir de dados experimentais da impedância, em camundongos machos do tipo BALB/c normais, obtidos em dois equipamentos diferentes fez-se uma comparação utilizando como base o Modelo de Fase Constante, analisando possíveis divergências e buscando compreender os motivos de eventuais discrepâncias. Um dos equipamentos (flexiVent, SCIREQ, Canadá) emprega o método convencional enquanto o outro equipamento foi desenvolvido pelo grupo do professor Zoltán Hantos, da Universidade de Szeged, Hungria, e se utiliza do método de wavetube. Tal trabalho foi motivado pela ausência de referências bibliográficas que comparam os dois métodos. A análise dos resultados experimentais nos sugere que os parâmetros obtidos para o Modelo de Fase Constante nos dois equipamentos são diferentes e não comparáveis. / The input respiratory impedance can be obtained by two different methods of performing the Forced Oscillations Technique (FOT): conventional and wavetube method. In this dissertation, first we made a literature review focusing on issues of interest to this work, as definitions and models of impedance, description and theoretical basis for the realization of the two methods and description of the equipments used by each method. Using experimental data of impedance in BALB/c male mice, from two different equipments a comparison was made based on the Constant Phase Model, analyzing possible differences between them and trying to understand the reasons for any discrepancies. The first equipment (flexiVent, SCIREQ, Canada) uses the conventional method while the second one, developed by the research group of Professor Zoltán Hantos of the University of Szeged, Hungary, uses the wavetube method. This work was motivated by the lack of literature references comparing the model parameters obtained by both methods. The analysis of experimental results suggests that the equipments are different and not comparable.
|
10 |
Desenvolvimento de um aparelho portátil que emprega a técnica de oscilações forçadas para estudo do sistema respiratório / Development of a portable device that uses the forced oscilations technique to study the respiratory systemCosta, Bruno Bittencourt da 19 December 2012 (has links)
The use of forced oscillation technique (FOT) to study the mechanical properties of the respiratory system was proposed by Dubois (1956). This technique allows studying the mechanical behavior of the respiratory system, and from models, extracting features of pulmonary mechanics that would be barely noticeable by other methods. The object of this work was to build a portable device that uses the forced oscillation
technique so that tests could be performed in locations with limited space. The device of TOF2 was remodeled from an early version called TOF1. Its components are integrated by replacing the set of equipment, power, signal generator, pressure transducers and data acquisition board with a single portable system. It was also developed a processing system for the collected data. In the validation process of TOF2 the pressure transducers were calibrated, the acquisition and data processing approach were defined, a standard resistance-inertance-compliance (RIC) model was built (analogue), and compared to the known value of impedance with the measured values in TOF2. The resulting procedure is analogous to that used in characterization of electric resistances. The reproducibility
of the resistance measurements with TOF2 coupled to the analogue, along with the coherence function was greater than 95%, which indicates a good reliability. We conclude that the developed device, called TOF2, includes all the instrumentation
needed to perform the measurements of a conventional TOF instrument, and meets the general recommendations for the design and implementation of the measurement system. / O uso da Técnica de Oscilações Forçadas (TOF) no estudo das propriedades mecânicas do sistema respiratório foi proposto por DUBOIS (1956). Essa técnica permite estudar o
comportamento mecânico do sistema respiratório e, a partir de modelos, extrair características da mecânica pulmonar que seriam pouco perceptíveis por outros métodos. O objeto deste trabalho foi a construção de um aparelho portátil que utiliza a
técnica de oscilações forçadas para que os exames pudessem ser realizados em locais com pouco espaço. O aparelho da TOF2 foi remodelado a partir de uma versão inicial denominada TOF1. Seus componentes foram integrados substituindo o conjunto de aparelhos, fonte, gerador de sinais, transdutores de pressão e placa de aquisição de dados por um único sistema portátil. Foi desenvolvido também um sistema de processamento dos dados coletados. No processo de validação do TOF2 foram calibrados os transdutores de pressão, definidos a aquisição e o processamento dos dados, foi construído um modelo resistência-inertância-complacência (RIC) padrão (analogue) e comparou-se o valor de impedâncias conhecidas com os valores mensurados no TOF2. Os resultados foram compatíveis aos valores obtidos na
caracterização das resistências. A reprodutibilidade das medidas de resistência com o TOF2 acoplado ao analogue, juntamente com a função de coerência foi superior a 95%,o que indica uma boa confiabilidade dos dados. Conclui-se que o aparelho
desenvolvido, denominado TOF2, inclui toda a instrumentação necessária para realizar as medições convencionais de um aparelho TOF, e cumpre as recomendações gerais para a elaboração e implementação do sistema de medidas.
|
Page generated in 0.0912 seconds