• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 6
  • 6
  • 6
  • 6
  • 6
  • Tagged with
  • 33
  • 33
  • 33
  • 33
  • 27
  • 26
  • 26
  • 14
  • 13
  • 9
  • 9
  • 8
  • 8
  • 8
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Influência da presença e do tipo de retentor intrarradicular no comportamento em fadiga de incisivos centrais restaurados com coroas totais /

Andrade, Guilherme Schmitt de. January 2019 (has links)
Orientador: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Coorientador: Lilian Costa Anami / Banca: Carlos Eduardo Francci / Banca: Clovis Pagani / Resumo: Este estudo avalia a influência da presença e tipo de pinos e núcleos na sobrevivência à fadiga de incisivos centrais restaurados com coroas totais. As coroas de 69 incisivos bovinos foram cortadas e as raízes tratadas endodonticamente. As raízes foram distribuídas aleatoriamente em três grupos (n = 23): núcleo de resina composta (NRC), núcleo de resina composta retido por pino de fibra de vidro (PFV) e núcleo metálico fundido (NMF). Todos receberam preparo de coroa total com férula de 2 mm, e então, uma coroa de cerâmica reforçada com leucita foi adesivamente cimentada. Três amostras de cada grupo foram testadas para determinação da carga máxima até a falha. As amostras restantes foram carregadas pelo teste acelerado de fadiga stepwise stress até a fratura ou suspensão após o término de 1,5 x 106 ciclos. A carga e o degrau em que cada espécime falhou foram analisadas pela estatística de Kaplan-Meier e Mantel-Cox (Log Rank test), seguidas por comparação múltipla aos pares, com nível de significância de 5%. O modo de falha foi analisado com estéreomicrocópio. Não houve diferença estatística entre os tratamentos quanto à carga (Mantel-Cox Log-Rank test for trend, X2=0,015, df=1, p=0,901), nem para o número de ciclos (Mantel-Cox Log-Rank test for trend, X2 =3,171, df=1, p=0,995). O modo de falha predominante foi a trinca da coroa. Fratura obliqua da raiz só foi observado nos grupos retidos por pinos. Nos incisivos tratados endodonticamente com férula de 2 mm, a presença e o tipo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : This study evaluates the influence of presence and type of post-and-core systems on fatigue survival of non-vital central incisors restored with all-ceramic crowns. The crowns of 69 bovine incisors were cut and endodontically treated. The roots were randomly assigned into three groups (n=23): composite resin build-up (NRC), glass fiber post-retained-composite build-up (PFV) and cast post-and-core (NMF). All specimens received crown preparation with a 2 mm ferrule, and then a leucite-reinforced ceramic crown was adhesively cemented. Three samples from each group were tested for the determination of the maximum load to failure. The remaining samples were loaded by the accelerated fatigue stepwise stress test until fracture or suspension after the end of 1.5 x 106 cycles. The load and the step on which each specimen failed were analyzed by the Kaplan-Meier and Mantel-Cox (Log Rank test) statistics, followed by multiple paired comparisons, with a significance level of 5%. The failure mode was analyzed with stereomicroscope. There was no statistically significant difference between the treatments (Mantel-Cox Log-Rank test for trend, X2=0.015, df=1, p=0.901), nor for the number of cycles (Mantel-Cox Log-Rank test for trend, X2=3.171, df=1, p=0.995). The predominant failure mode was the crown crack. Oblique root fracture was observed only in groups retained by posts. The presence and type of post system did not influence the fatigue survival of the endodontically treated incisors with a 2 mm ferrule. Non-restorable fractures only occurred on teeth restored with posts...(Complete abstract click electronic access below) / Mestre
22

Estudo dos efeitos da oscilação do molde na produção de tarugos por lingotamento contínuo /

Gonçalves, Camilla Gandine. January 2016 (has links)
Orientador: José Geraldo Trani Brandão / Banca: Francisco José Grandinetti / Banca: Fernando de Azevedo Silva / Banca: Viktor A. Pastoukhov / Banca: César Alves da Silva Leandro / Resumo: O objetivo deste trabalho é estudar a oscilação do molde na produção de tarugos por lingotamento contínuo e a sua consequência na qualidade do produto final, através de modelamento matemático. A oscilação do molde origina um defeito superficial conhecido como marca de oscilação. O modelo da formação das marcas considera três partes: térmica, mecânica dos fluidos e mecânicos dos sólidos. São consideradas as fases sólida e pastosa, até certa fração sólida, como resistentes aos esforços advindos da oscilação, e que o raio do menisco é não estacionário. Verifica-se que o aumento do curso de oscilação do molde aumenta a profundidade das marcas de oscilação, o aumento da frequência de oscilação tem comportamento ascendente até um ponto máximo, seguido de descendente, enquanto o aumento da velocidade de lingotamento aumenta a profundidade das marcas, desde que a frequência e curso sejam mantidos constantes. O estripamento negativo aparenta ser função de todas as demais variáveis de processo. / Abstract: This work aims to study the mold oscillation in continuous casted billets and its consequence on the final product quality throw mathematical modeling. The mold oscillation causes a surface defect known as oscillation marks. The model of oscillation marks formation is divided in three parts: thermal, fluid mechanics and mechanics of solids. Two phases, solid and mushy steel above to a certain solid fraction are considered as having mechanical strength, and the meniscus radius is non stationary. It appears that the increasing in stroke increases the depth of the oscillation marks, increasing the oscillation frequency is upward behavior up to a maximum point, followed by descending, while increasing the casting speed increases the depth of oscillation marks, if frequency and stroke is kept constant. The negative strip time appears to be a function of all other process variables. / Doutor
23

Comparação da eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares: uma análise de elementos finitos tridimensional / Efficiency comparison in stress distribution of different post types: a 3D finite element analysis

Eric Mayer dos Mayer-Santos 03 November 2016 (has links)
Elementos dentais endodonticamente tratados geralmente necessitam de retentores intrarradiculares para prover retenção e suporte ao processo restaurador. O objetivo deste estudo foi comparar a eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares, através do método dos elementos finitos. Um modelo tridimensional de elementos finitos foi desenvolvido para representar um incisivo central superior endodonticamente tratado e restaurado com uma coroa total cerâmica, e quatro tipos diferentes de pinos pré-fabricados (dois convencionais, e dois modelos customizados) foram inseridos sob esse modelo e comparados quanto à distribuição das tensões às quais foram submetidos. Os quatro pinos diferem em formato e material de composição. O primeiro é um pino pré-fabricado metálico customizado referente à uma patente, com porção coronária anatômica (com curvaturas e formatos semelhantes à coroa anatômica) e flange rosqueável. O segundo pino pré-fabricado é semelhante em formato ao primeiro pino, mas será composto por fibra de vidro. O terceiro é um pino metálico pré-fabricado convencional, sem presença de flange. O quarto pino é semelhante ao terceiro pino em formato, mas será composto por fibra de vidro. Foi aplicada sobre os modelos uma mesma força estática média de 100 N com uma angulação de 135 graus ao longo eixo do dente no centro da face palatina do modelo, com o objetivo de simular a carga mastigatória e obter a distribuição das tensões. A avaliação apresentou os resultados considerando os critérios de Von Mises e tensões máximas principais. Os resultados mostraram que os pinos metálicos customizados resultaram em menores tensões à dentina e à estrutura coronária quando comparados aos pinos convencionais, e que ambos os pinos metálicos apresentaram menores tensões à estrutura coronária se comparados aos pinos em fibra de vidro. Em relação à estrutura dentinária, os pinos metálicos e os pinos em fibra de vidro apresentaram resultados semelhantes quanto à distribuição de tensões. Os modelos em fibra de vidro apresentaram resultados semelhantes em ambas as avaliações. Conclui-se que os modelos customizados foram superiores aos convencionais quando compostos pela liga metálica, mas semelhantes quando compostos por fibra de vidro. / Endodontically treated teeth commonly require a post to provide retention and support to the restorative process. The aim of this study was to compare the efficiency of the distribution stresses of different models of posts through the finite element method. A three-dimensional finite element model was developed to represent an endodontically treated maxillary central incisor restored with a ceramic crown, and four different types of prefabricated posts (two conventional and two customized models) have been inserted in that model and compared regarding the distribution of the stresses to which they were subjected. The four posts differ in size and material composition. The first is a custom metal prefabricated post relating to a patent, with anatomical coronal portion (with curvatures and format similar to the anatomical crown) and threaded flange. The second prefabricated post is similar in format to the first post, but is composed of fiberglass. The third is a conventional prefabricated metal post without the flange. The fourth post is similar to the third in format, but is composed of fiberglass. It was applied on the models the same average static occlusal force of 100N with an angle of 135 degrees to the tooth long axis in the palatal surface of the crown, with an objective of simulate the masticatory load and obtain the stress distribution. The evaluation presented the results considering the Von Mises and Maximum principal stress criteria. The results showed that the customized metal posts resulted in lower stresses to dentin and coronal tooth structure when compared to conventional posts, and both metallic posts had lower stresses in the coronal portion structure compared to glass fiber posts. Regarding the dentinal structure, metal posts and fiberglass posts showed similar results of stresses. The fiberglass models showed similar results in both evaluations. We conclude that the custom models were superior to conventional posts when composed by metal, but similar when composed of fiberglass.
24

Análise mecânica de retentores intra-radiculares / Mechanical analysis of endodontic post

Novais, Veridiana Resende 17 August 2018 (has links)
Orientador: Carlos José Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T13:46:14Z (GMT). No. of bitstreams: 1 Novais_VeridianaResende_D.pdf: 2459662 bytes, checksum: 08447cf6179bf7f73a335f129557029a (MD5) Previous issue date: 2010 / Resumo: Este estudo avaliou os aspectos mecânicos de retentores intra-radiculares pré-fabricados reforçados com fibra, de forma progressiva por meio de etapas distintas e seqüenciais, divididas em três experimentos. No Capítulo 1, foram avaliados parâmetros como: efeito da conicidade do pino, distância entre os suportes, e propriedades dos pinos na flexão e tensão máxima pelo método de elementos finitos na realização de ensaios de flexão de 3 pontos. Foi gerado modelo tri-dimensional de pino de fibra de vidro (RelyX post, 3M-Espe), variando posições dos suportes inferiores e inclinação do pino. Empregou-se propriedades elásticas, características ortotrópicas e isotrópicas. A inclinação dos pinos cônicos para nivelá-los nos suportes teve pouco efeito nas tensões. A flexão aumentou quando 50% da porção carregada do pino envolveu conicidade. Quando o posicionamento do pino envolveu 20% da porção cônica, os valores de flexão foram similares ao modelo de referência, que é o pino cilíndrico, sem inclinação. Propriedades ortotrópicas resultaram em aumento da flexão comparado ao pino isotrópico. No Capítulo 2, propriedades mecânicas de diferentes sistemas de pinos pré-fabricados foram avaliadas por ensaio experimental de flexão de três pontos, assim como análise da correlação entre propriedades mecânicas e características estruturais visualizadas por microscopia eletrônica de varredura associado à software de processamento de imagens. Os resultados demonstraram que as características estruturais afetaram significativamente as propriedades mecânicas dos pinos. Resistência à flexão está diretamente correlacionada com a razão fibra/matriz de resina, enquanto módulo de flexão está inversamente relacionado ao número de fibras/mm2. No Capítulo 3, foi avaliada resistência de união de pino de fibra ao núcleo de preenchimento de resina composta por meio do teste de push-out, variando o tipo de agente silano: três silanos pré-hidrolizados e um sistema de silano de dois componentes; e a temperatura de secagem com ar após aplicação do silano: 23°C e 60°C. Empregou-se ainda grupo controle negativo, no qual nenhum tratamento do pino foi realizado. A aplicação de silano pré-hidrolizado e secagem com ar quente (60°C) dos pinos não influenciou a resistência de união. O agente silano de dois componentes com temperatura de secagem de 23°C apresentou os maiores valores de resistência de união. Desta forma, dentro das limitações dos três experimentos, conclui-se que teste de flexão de três pontos empregado para avaliação de pinos pré-fabricados é válido quando limita a área de ensaio à porção cilíndrica dos pinos; as características estruturais dos pinos têm correlação com as propriedades mecânicas dos mesmos; e a aplicação de ar quente sobre as superfícies de pinos silanizados não tem efeito significativo na resistência de união entre pinos de fibra e preenchimento com resina composta / Abstract: The fiber-reinforcement composite (FRC) posts introduced the new concept of restorative system, in which the various components of the reconstruction: post, cement, filling material and dentin have now become a complex mechanically homogeneous. The knowledge of the structure, composition and physical properties of these fiber posts systems is important in order to minimize the failures and the unsuccessfully clinical. Thus, the present study was conducted to analyze sequentially the biomechanical parameters of FRC posts through different stages divided into three experiments. In Chapter 1, the effect of taper, specimen supports and the properties on flexure and stress response during three-point bending were analyzed using finite element analysis. Three-dimensional non-linear finite element model of a fiber-reinforced composite post was created. Different support positions were evaluated during a simulated three-point bending test. The applied properties were elastic and orthotropic. Tilting the tapered posts to level those in the test setup had little effect on the outcome. Flexure increased when 50% of the bent portion involved taper. If 20% of the bent post involved taper, the flexure values were close to control group. The orthotropic properties also resulted in increased flexure compared to an isotropic post. Maximum stresses were only a little higher when 50% of the bend structure involved taper, while the orthotropic properties had little effect. In Chapter 2, the mechanical properties of different FRC posts were assessed with three-point bending test and evaluated the correlation between mechanical properties and structural characteristics by scanning electron microscopy (SEM) associated with an software of image processing. Then, the structural characteristics significantly affect the mechanical properties of fiber posts. The flexural strength is directly correlated with fiber/matrix ratio, whereas the flexural modulus is inversely correlated with number of fibers per mm2 of post. In the Chapter 3, was evaluate the effect of three prehydrolyzed silanes and one two-bottle coupling agent and two air-drying temperature (23°C and 60°C) on the bond strength between glass fiber posts and composite resin core using micropush-out testing. Additionally, it was tested a control group, which no treatment of fiber post were realized. The results showed that drying with warm air and post silanization with pre-hydrolized silanes had no significant effect on push-out bond strength between glass fiber post and composite resin core. For 23°C air-drying groups, the bond strength with two-bottle coupling agent was higher than the other groups. Then, based on the findings of this study, and within the limitation of this investigation, could be concluded that the regardless of leveling, the flexural stress determination with tapered fiber-reinforced posts in the three-point bending test was valid as long as the tapered portion was limited. Additionally, the mechanical properties have correlation with structural characteristics of FRC posts. Finally, the warm air-drying in silanizated post surface had not significant effect on bond strength between fiber post and composite resin core / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
25

Influencia da altura do remanescente coronario, do tipo de retenção intra-radicular e do tipo de coroa total na resistencia e modo de fratura de raizes bovinas / Influence of coronal tooth structure, type of intraradicular retention and total crown on fracture strength and mode of failure of bovine roots

Resende, Cristina do Amparo 24 September 2007 (has links)
Orientadores: Luis Roberto Marcondes Martins, Carlos Jose Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T14:12:54Z (GMT). No. of bitstreams: 1 Resende_CristinadoAmparo_D.pdf: 3071325 bytes, checksum: 2b04a3fed0292eea5d925854e4ace595 (MD5) Previous issue date: 2007 / Resumo: O objetivo deste estudo foi avaliar a resistência à fratura de raízes bovinas tratadas endodonticamente e restauradas com diferentes retenções intra-radiculares variando-se o tipo de material da coroa total, na presença e ausência do remanescente coronário. Duzentas raízes com dimensões padronizadas foram divididas aleatoriamente em 20 grupos experimentais (n=10) nos seguintes tratamentos: retenções: pino de fibra de vidro (PFV), pino de fibra de vidro reembasado (PFVR), fibra de polietileno (FP), preenchimento do canal com resina composta (RC) e núcleo metálico fundido (NMF); remanescente: ausente ou com 2 mm de altura; coroa total: cerômero ou cerâmica pura. As coroas totais foram cimentadas com cimento resinoso e as raízes foram fixadas em resina poliestirênica, simulando-se o ligamento periodontal com material de moldagem à base de poliéter. As amostras foram submetidas ao carregamento tangencial de compressão, sob um ângulo de 135º a 0,5 mm/min até ocorrer a falha. Os resultados (ANOVA / Tukey a=0,05) demonstraram que houve diferença estatisticamente significante entre os tipos de pinos (p=0,0058), sendo os grupos restaurados com PFVR e RC apresentaram os maiores valores de resistência à fratura, não diferindo estatisticamente dos grupos restaurados com PFV e PF, e os grupos restaurados com núcleos metálicos fundidos apresentaram os menores valores, não diferindo estatisticamente dos grupos restaurados com PFV e PF. Para os tipos de coroa total (p<0,0001), os grupos restaurados com coroas em cerômero apresentaram maiores valores de resistência à fratura em relação aos grupos restaurados com coroas em cerâmica pura. Os grupos restaurados com fitas de fibra de polietileno mais frequentemente apresentaram padrão de fratura favorável, enquanto os restaurados apenas com resina composta apresentaram padrão de fratura desfavorável, seguidos dos núcleos metálicos fundidos. Para os tipos de coroa total, os grupos restaurados com coroas em cerâmica pura mais frequentemente apresentaram padrão de fratura favorável quando comparados aos grupos restaurados com cerômero, sendo que o mesmo ocorreu para os grupos sem remanescente coronário, quando comparados aos grupos com 2 mm de remanescente / Abstract: The objective of this study was to evaluate the fracture strength of bovine roots endodontically treated and restored by different intraradicular retention varying the type of material of the total crown, in presence or absence of the coronal tooth structure. Two hundred roots with standardized dimensions was divided randomly into 20 experimental groups (n=10) in the following treatments: retentions: fiber glass post, (PFV), relined fiber glass post (PFVR), polyethylene fiber ribbon post (FP), filling of root with composite resin (RC) and cast post and core (NMF); coronal remainder: absence or presence of 2 mm of coronal structure height; total crown: ceromer or all ceramic crown. Total crowns were luted with resin cement and the roots were fixed in resin blocks and artificial periodontal ligament was simulated with casting material made of polyether. The specimens were submitted to compressive strength test at 135º and 0,5 mm/min until fracture occurred. The results (ANOVA/Tukey a=0,05) showed that it had statistical significant difference among the types of retentions (p=0,0058), being the groups restored with PFVR and RC showed the higher failure loads, not differing statistically from groups restored by PFV and PF, and the groups restored by cast post and core showed lower failure loads, not differing statistically from groups restored by PFV and PF. For the types of total crown (p< 0.0001), the groups restored by ceromer crowns showed higher failure loads than did groups restored by all ceramic crowns. The groups restored by polyethylene fiber ribbon post more frequently showed favorable failure modes, while the restored ones only by composite resin showed unfavorable failure modes, followed by cast post and core. For the types of total crown, the groups restored by all ceramic crowns more frequently showed favorable failure modes than did groups restored with ceromer crowns, being that the same it occurred for the groups without coronal tooth structure, when compared to the groups with 2 mm of coronal structure height / Doutorado / Dentística / Doutor em Clínica Odontológica
26

Efeito da solução de clorexidina a 2% a um cimento ionomérico e um resinoso na adesão de pinos de fibra de vidro em raízes bovinas após 7 dias e 6 meses de armazenamento / Effect of 2% chlorhexidine solution on bonding of a glass ionomer cement and a resin cement to bovine root dentin after 7-day and 6-month storage

Diana Ferreira Gadêlha de Araújo 08 March 2013 (has links)
Este trabalho avaliou a influência do uso de solução de clorexidina a 2% (CHX) na resistência de união de pino de fibra de vidro à dentina radicular, utilizando um agente cimentante ionomérico modificado por resina e um cimento resinoso dual com sistema adesivo convencional, nos terços cervical, médio e apical. Oitenta raízes bovinas foram selecionadas, cortadas em 17mm e tratadas endodonticamente para em seguida serem divididas em 8 grupos: ARC (RelyX ARC/ScothBond MultiPurpose- cimento resinoso); ARC+CHX (ARC associado a CHX); RL (RelyX Luting 2- ionômero de vidro); RL+CHX (RL associado a CHX). Os espécimes de cada protocolo foram divididos em grupos de 7 dias ou 6 meses de armazenamento, depois de serem restaurados com pino de fibra de vidro cônico Exacto. Após 24 horas da cimentação, as raízes foram seccionadas perpendicularmente ao longo eixo e identificadas quanto à região, obtendo-se fatias (1mm de espessura). Após o tempo de armazenamento proposto, todas as fatias foram submetidas ao teste de extrusão (push-out) com célula de carga a 0,5mm/min. Os dados foram tabelados considerando as variáveis dos diferentes agentes cimentantes, uso ou não de solução de clorexidina, terços radiculares e tempo de armazenamento. Depois de testados, todos os espécimes foram submetidos à análise dos tipos de fraturas encontradas. Os valores de resistência obtidos foram submetidos à análise estatística através do teste ANOVA a quatro critérios e comparações múltiplas com Tukey, ambos com p<0,05. Os valores obtidos para os grupos armazenados por 7 dias nos terços cervical, médio e apical, respectivamente, foram: ARC- 4,03 (1,85); 4,68 (2,76); 2,97 (1,56); ARC+CHX- 6,75 (3,01); 5,28 (2,89); 3,98 (3,40); RL- 2,26 (0,48); 1,97 (1,31); 1,69 (0,75); RL+CHX- 2,26 (0,96); 2,10 (0,93); 1,65 (1,40). Para os grupos armazenados por 6 meses, os valores resultantes foram: ARC- 6,57 (2,43); 6,56 (2,85); 5,15 (3,07); ARC+CHX- 3,23 (3,13); 1,75 (1,28); 3,26 (2,10); RL- 2,02 (1,13); 1,90 (1,33); 1,40 (1,43); RL+CHX- 1,06 (0,70); 0,78 (0,38); 0,88 (0,90). A análise das fraturas encontrou predominância de falhas adesivas entre cimento e dentina e mistas para os grupos cimentados com ARC. Grupos cimentados com RL apresentaram maioria de falhas do tipo mista e adesiva entre cimento e pino. Os cimentos apresentaram desempenho semelhante para o teste imediato, mas o ARC obteve melhor desempenho após 6 meses de armazenamento. A CHX não exerceu influência positiva para nenhuma das situações testadas. Não foram encontradas diferenças significantes entre os terços de um mesmo grupo. A resistência adesiva foi influenciada principalmente pelo tipo de cimento utilizado. / This study evaluated the influence of 2% chlorhexidine digluconate (CHX) on glassfiber post bonding strength to root dentin with a dual-cured resin cement and a resinmodified glass-ionomer cement, in terms of coronal, middle, and apical thirds. Eighty bovine roots were sectioned 17mm from their apices and endodontically treated and randomly assigned into eight groups: ARC (dual-cured resin cement RelyX ARC + ScothBond Multi Purpose adhesive system); ARC+CHX (ARC associated with CHX); RL (resin-modified glass-ionomer cement RelyX Luting 2) and RL+CHX (RL associated with CHX). Half of each group was subjected to either 7-day or 6-month storage in artificial saliva, after being restored with glass-fiber post Exacto. After 24 hours of luting, the roots were sliced under irrigation to obtain 1mm-thick slices. After the storage time, slices were subjected to push-out test with a universal test machine with a crosshead speed of 0.5mm/min. After this test, the slices were submitted to analysis of failure modes. Data of bond strength were submitted to four-way ANOVA and Tukeys tests (p&#x2264;0.05). The values of average and standard deviation (MPa) regarding coronal, middle, and apical thirds for 7-day groups were: ARC- 4.03 (1.85); 4.68 (2.76); 2.97 (1.56); ARC+CHX- 6.75 (3.01); 5.28 (2.89); 3.98 RL- 2.26 (0.48); 1.97 (1.31); (3.40); 1.69 (0.75); RL+CHX- 2.26 (0.96); 2,10 (0.93); 1.65 (1.40). After 6-month storage, the respectively values obtained were: ARC- 6.57 (2.43); 6.56 (2.85); 5.15 (3.07); ARC+CHX- 3.23 (3.13); 1.75 (1.28); 3.26 (2.10); 1.40 (1.43); RL- 2.02 (1.13); 1.90 (1.33); RL+CHX- 1.06 (0.70); 0.78 (0.38); 0.88 (0.90). The most observed failures were adhesive cement-dentin and mixed failures for ARC groups; for the RL groups, the main failures were adhesive cement-post and mixed modes. Immediate values showed similar performance between both tested cements. After 6 months, ARC yielded higher bond strength compared to RL. For any tested situation, CHX exhibited improved bond strength, disregarding neither luting cement nor time.
27

Avaliação longitudinal da resistência de união de pinos de fibra de vidro à dentina cimentados com quatro agentes cimentantes por meio do teste de push-out

Rosalyn Chidiak Tawil 02 December 2008 (has links)
Avaliou-se a resistência de união do pino de fibra de vidro à dentina cimentado com quatro agentes cimentantes, por meio do teste push-out realizado após 24 horas e seis meses de armazenagem. Foram selecionados 80 dentes humanos uniradiculares, tratados endodonticamente e divididos aleatoriamente em quatro grupos (n=20), variando-se o tipo de cimento utilizado: grupo I: cimento de ionômero de vidro reforçado com resina (Fuji PlusTM, GC Corp., Tokyo, Japan); grupo II: cimento resinoso usando sistema adesivo convencional de 3 passos de aplicação (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); grupo III: cimento resinoso usando sistema adesivo autocondicionante de 1 passo de aplicação (PanaviaTM F, Kuraray, Osaka, Japan); e grupo IV: cimento resinoso auto-adesivo (BisCemTM, Bisco Inc., Schaumburg, IL). Cada grupo foi subdividido em dois subgrupos (N=10) variando-se o tempo de armazenagem (24 horas e seis meses). O teste de push-out foi realizado com uma velocidade de 1,0 mm/min, e os resultados expressos em Mega Pascal (MPa). Após o teste de push-out, todos os espécimes foram observados em microscópio óptico de fluorescência (40x) e analisado o tipo de falha apresentado entre o complexo pino/cimento/dentina radicular. Os valores médios de resistência (MPa) foram submetidos ao teste ANOVA a dois critérios e de Tukey (p<0,005). A análise estatística mostrou: 1) Diferenças significativas na resistência de união entre os cimentos utilizados, sendo que a média total do cimento resinoso RelyXTM ARC + ScotchbondTM MultipurposeTM foi superior aos dos outros cimentos após 24 horas; 2) A resistência de união dos cimentos resinosos RelyXTM ARC + ScotchbondTM MultipurposeTM e PanaviaTM F foram superiores aos outros cimentos quando testados após seis meses de armazenagem e não houve diferença significativa entre eles; 3) Após seis meses de armazenagem, observou-se um aumento na resistência de união de todos os cimentos; 4) Na análise por terços, foi observado que tanto após 24 horas quanto após seis meses, o terço cervical teve uma maior resistência de união do que o terço médio e apical; 5) Foram observadas predominantemente falhas mistas, apresentado-se na maioria dos casos a combinação de falha adesiva na interface pino/cimento e na interface cimento/dentina para todos os grupos. Concluiu-se que a resistência de união aumentou após seis meses de armazenagem graças possivelmente à expansão higroscópica e aumento da retenção friccional. / The bond strength of a glass fiber post luted to dentin with four luting agents was evaluated using the push-out test, after 24-hours and six months of storage. Eighty human single-routed teeth was selected, endodontically treated and randomly divided into four groups (n=20), modifying the luting agent used: group I: resin modified glass-ionomer (Fuji PlusTM, GC Corp., Tokyo, Japan); group II: resin cement using total-etch, three step adhesive system (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); group III: resin cement using self-etch one step adhesive system (PanaviaTM F, Kuraray, Osaka, Japan); and group IV: self-adhesive resin cement (BisCemTM, Bisco Inc., Schaumburg, IL). Each group was, then, subdivided into two subgroups (n=10) modifying the storage period (24-hours and six months). The push-out test was performed with a cross-speed of 1,0 mm/min, and the results expressed in Mega Pascal (MPa). After the test, all specimen interfaces were examined with the aid of a fluorescence optic microscope (40x) to dertemine the type of failure at the complex post/cement/dentin. The mean values of the bond strength (MPa) were analyzed with the two-way ANOVA and Tukey test (p<0,005). The statistical analysis showed: 1) Significant difference in the bond strength between the luting agents, in wich the mean total value of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM was the highest after 24 hours; 2) The bond strength of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM and PanaviaTM F were higher than the others luting agents when evaluated after six months, and there was no significant difference among both of them; 3) An increase in the bond strength of all luting agents after six months of storage in distilled water; 4) That the cervical third had a higher bond strength compared to the middle and apical thirds for all materials, during third analysis after 24-hours and six months of storage; 5) Predominantly, it was observed mixed failures, in the majority of the cases, with a combination of adhesive failure in the post/luting agent interface and in the luting agent/radicular dentin interface. Therefore, can be concluded that the bond strength of a glass fiber post luted to dentin with different luting agents can increase after six months of storage, possibly contributed by hygroscopic expansion and the increase of the frictional retention.
28

Resistência de união regional de pinos de fibra de vidro fixados com cimentos resinosos experimentais contendo sal de ônio e diferentes aminas terciárias / Regional bond strength of fiber glass posts fixed with experimental resin cements containing onium salts and different tertiary amines

Leite, Thatiana de Vicente, 1988- 04 May 2013 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T21:20:40Z (GMT). No. of bitstreams: 1 Leite_ThatianadeVicente_M.pdf: 962489 bytes, checksum: 384dca92c91450403a7ee6a9653d3bef (MD5) Previous issue date: 2013 / Resumo: O objetivo deste trabalho foi avaliar, in vitro, a resistência de união (push-out) regional (terços cervical, médio e apical) de pinos de fibra de vidro (Reforpost #3, Ângelus Indústria de Produtos Odontológicos S/A, Londrina, PR) fixados com cimentos resinosos experimentais foto-ativados, contendo diferentes concentrações do sal hexafluorfosfato de difeniliodônio (DFI), variando as aminas terciárias entre EDAB e DMAEMA, e compará-los a um cimento resinoso disponível no mercado em sua versão dual e foto-ativável. Foram utilizadas 80 raízes de incisivos inferiores bovinos com 15 mm de comprimento e diâmetro do canal máximo de 2 mm, as quais foram divididas em 8 grupos experimentais (n = 10). Os grupos experimentais são descritos a seguir: G1 - cimento resinoso experimental, sem adição do sal DFI, contendo 2 mol % de EDAB; G2 - cimento resinoso experimental, com adição de 0,5 mol % do sal DFI, contendo 2 mol % de EDAB; G3 - cimento resinoso experimental, com adição de 1 mol % do sal DPI, contendo 2 mol % de EDAB; G4 - cimento resinoso experimental, sem adição do sal DFI, contendo 2 mol % de DMAEMA; G5 - cimento resinoso experimental, com adição de 0,5 mol % de DFI, contendo 2 mol % de DMAEMA; G6 - cimento resinoso experimental, com adição de 1 mol % de DFI, contendo 2 mol % de DMAEMA; G7 - cimento resinoso comercial Variolink II, versão foto-ativável, utilizando apensas a pasta base; G8 - cimento resinoso comercial Variolink II (Ivoclar-Vivadent), versão dualmente ativável, utilizando as pastas base e catalisadora. Para todos os grupos, o protocolo adesivo utilizado foi condicionamento ácido, seguido pela aplicação do primer e bond Scotchbond Multipurpose (3M ESPE). Após a cimentação, o teste de resistência de união push-out foi realizado a uma velocidade de 1 mm/min, utilizando uma célula de carga de 200 N e os valores expressos em MPa. A análise do padrão de fratura foi realizada em lupa estereoscópica (LEICA MZ75 50X). Os dados coletados foram submetidos à Análise de Variância a um critério com parcelas subdivididas e teste de Tukey (?=0.05). Os resultados obtidos demonstraram que não houve diferença estatística entre o comportamento dos cimentos devido à influência das diferentes aminas; os cimentos experimentais resinosos que continham o sal DFI (grupos 2,3,5 e 6) apresentaram os maiores valores de resistência de união para todos os terços estudados (cervical, médio e apical), sendo estes estatisticamente semelhantes ao cimento resinoso comercial Variolink II dual (grupo 8). Os menores valores apresentados foram para os cimentos que não continham o sal DFI (grupos 1 e 4) e para o cimento resinoso comercial Variolink II foto-ativável (grupo 7), sendo estes estatisticamente semelhantes no terço apical. O cimento resinoso experimental foto-ativável contendo sal de DFI se mostrou capaz para a cimentação de pinos de fibra de vidro, sendo estatisticamente semelhantes ao cimento resinoso comercial Variolink II Dual, e superiores ao mesmo cimento em sua versão fotoativável. A região apical demonstrou para todos os grupos os menores valores de resistência de união. O tipo de amina terciária e a concentração do sal de DFI (0,5 e 1 mol %) não influenciaram a resistência de união de pinos de fibra de vidro à dentina radicular / Abstract: The aim of this study was to evaluate, in vitro, the bond strength (push-out) of fiber posts fixed with experimental photo-activated resin cements with the addition of different concentrations of hexafluorophosphate dipheniliodonium salt (DFI), also varies between tertiary amines EDAB and DMAEMA in cementation of fiber posts, and compare them to a resin cement available in the market in its dual and photo-activatable version. A total of 80 bovine incisors roots of similar dimensions were used, which were divided into eight experimental groups (n = 10). Experimental groups are described below: G1 - experimental resin cement without addition of DFI salt, containing 2 mol% EDAB; G2 - experimental resin cement, with addition of 0.5 mol% of DFI salt containing 2 mol % of EDAB; G3 - experimental resin cement with addition of 1 mol% of DFI salt, containing 2 mol% EDAB; G4 - experimental resin cement without addition of DFI salt, containing 2 mol% DMAEMA; G5 - experimental resin cement, with addition of 0.5 mol% DFI salt, containing 2 mol% DMAEMA; G6 - experimental resin cement with the addition of 1 mol% DFI salt, containing 2 mol% DMAEMA; G7 - commercial resin cement Variolink II, photo-activatable version, using the base paste; G8 - commercial resin cement Variolink II, version dually activatable, using the base and catalyst pastes. For all groups, the adhesive protocol used was, etching, followed by application of primer and bond Scotchbond Multipurpose. After cementation, the bond strength test push-out was conducted at a speed of 1 mm / min, using a load cell of 200 N and the values expressed in MPa. The pattern of fractures was performed by stereoscopy magnifier (LEICA MZ75 50X). The collected data were subjected to ANOVA for a split-plot criterion and the Tukey test (? = 0.05). The results showed that there was no statistical difference in the behavior of cements due to influences of the different amines; experimental resin cements containing salt DFI (groups 2,3,5 and 6) showed the highest bond strength for all the studied thirds (cervical, middle and apical), which are statistically similar to the commercial resin cement Variolink II Dual (group 8). The lowest values were submitted to the cements containing no DFI salt (groups 1 and 4) and the commercial resin cement Variolink II photo-activable (group 7), which were statistically similar in the apical third. The experimental resin cements containing DFI salt are capable for fiber glass posts cementation, being statistically similar to the commercial resin cement Variolink II Dual, and even above the cement in the version photo-activable. The variation of tertiary amines did not influence the results of bond strength and there was no statistically difference between the concentrations 0.5 mol% and 1 mol% of DFI salt / Mestrado / Materiais Dentarios / Mestra em Materiais Dentários
29

Avaliação da customização por desgaste de pinos pré-fabricados de fibra de vidro / Evaluation of fibre posts submitted to customization of the apical portion

Ana Regina Cervantes Dias 25 January 2012 (has links)
O objetivo deste estudo foi avaliar pinos pré-fabricados de fibra de vidro (White Post DC/FGM) submetidos à customização por desgaste da porção apical. Experimento 1: 5 pinos n. 4 foram divididos em 5 grupos (G) de acordo com o instrumento de desgaste: GA - sem desgaste, GB- mini torno industrial (Dentsply), GC - ponta diamantada n. 3195F (KG Sorensen), GD - disco de lixa de granulação média (Sof-Lex/3M/ESPE), GE- alicate (Tramontina). Observou-se a micromorfologia dos pinos em microscópio eletrônico de varredura (ZEISS/DSM 960). Experimento 2: 60 pinos de diferentes diâmetros foram divididos em 6 grupos: G0 - pinos n. 0,5, G1 - pinos n. 1, G2 - pinos n. 2, G3 - pinos n. 3, G4 - pinos n.4, G5 - pinos n. 4 com terço apical desgastado com discos de lixa até o equivalente ao terço apical dos pinos n. 2. Os pinos foram submetidos ao teste de flexão de 3 pontos na máquina de ensaios universal (Instron 5500 R), conforme ISO 10477. Experimento 3: 20 caninos humanos permanentes sofreram tratamento endodôntico e remoção das coroas clínicas padronizando 15 mm de remanescente radicular. Os dentes foram incluídos em resina acrílica com simulação do ligamento periodontal, receberam férula de 2 mm e foram divididos em 2 grupos: GI - pinos n. 4 cimentados em condutos preparados com broca equivalente ao pino (FGM), GII - pinos n. 4 customizados no terço apical cimentados em condutos preparados com brocas (FGM) equivalentes aos pinos n. 2 em 10 mm e n. 4 em 5 mm. Os pinos foram cimentados com cimento resinoso (Rely X U100/3M/ESPE), os corpos de prova receberam coroas diretas de resina composta (Enforce Core/Dentsply) padronizadas com coras de policarbonato (TDV) e foram submetidos ao teste de resistência à fratura na Instron a 45da ferramenta cilíndrica, com força de 500 N aplicada a 2 mm da incisal na face palatina/lingual, com velocidade de 0,5 mm/min até falha. O padrão de fratura foi classificado em favorável ou desfavorável. Os resultados foram tratados estatisticamente por teste de análise de variância (ANOVA, p<0,05). Os resultados dos testes de flexão e fratura foram respectivamente: G0 - 58,406,40; G1 - 83,959,43; G2- 103,4219,17; G3 - 160,7817,30; G4 - 170,4711,28; G5 - 106,3521,96; GI - 303,0262,21 e GII - 402,81131,97. O padrão de fratura foi tratado por Mann-Whitney que observou semelhança estatística entre os grupos. Concluiu-se que o desgaste de pinos de fibra de vidro com pontas diamantadas ou discos de lixa produz alterações micromorfológicas aceitáveis. O corte com alicate deve ser evitado. A customização por desgaste da porção apical de pinos de fibra de vidro diminui a resistência à flexão a valores aceitáveis. Dentes restaurados com pinos de fibra de vidro customizados por desgaste possuem resistência à fratura superior a dentes restaurados com pinos intactos. A customização por desgaste facilita a adaptação do pino ao conduto radicular e preserva a estrutura dental. / The purpose of this study was to evaluate fibre posts (White Post DC/FGM) submitted to customization of the apical portion. Experiment 1: 5 #4 posts were divided into five groups (G) and submitted to different custom adaptation treatments: GA no surface treatment, GB- industrial shaping tool (Dentsply), GC- #3195 fine diamond bur (KG Sorensen), GD- medium-grain paper discs (Sof-Lex/3M/ESPE), GE pliers (Tramontina). The micromorphology of the posts was observed in a scanning electron microscope (ZEISS/DSM 960). Experiment 2: 60 posts of different diameters were divided into six groups: G0 #0.5 posts, G1 #1 posts, G2 #2 posts, G3 - #3 posts; G4 - #4 posts and G5 #4 posts submitted to custom adaptation of the apical portion with paper discs until the diameter was equivalent to #2 posts. The posts were submitted to a 3 point bending test in a universal testing machine (Instron/5500 R), according to ISO 10477. Experiment 3: 20 freshly extracted permanent healthy human canines with similar size were endodontically treated and the crowns were removed, leaving a remaining root length of 15 mm. The teeth were embedded in acrylic resin with simulation of the periodontal ligament, received a 2 mm ferule and were divided into two groups: G1- 10 #4 posts were cemented into post spaces prepared with #4 drill (FGM) at 10 mm, G2 - 10 #4 customized posts were cemented into root spaces prepared with #2 drill (FGM) at 10 mm and #4 drill (FGM) at 5 mm. The posts were cemented with resin cement (Rely X U100/3M/ESPE), and the teeth received direct crowns of composite resin (Enforce Core/Dentsply), standardized with polycarbonate crowns (TDV). The fracture strength was measured on an Instron, at 45 degrees to the long axis of the tooth, until fracture. The 500 N cylindrical load was applied to the buccal/lingual axis 2 mm below the incisal line, at crosshead speed of 0.5 mm/min. The fracture pattern was observed and classified as favorable or unfavorable. The results were submitted to ANOVA (p<0.05). Flexural strength and resistance to fracture data were, respectively: G0 58.40+6.40; G1 83.95+9.43; G2 103.42+19.17; G3 160.78+17.30; G4- 170.47+11.28; G5 106.35+21.96;GI 303.02+62.21 and GII 402.81+131.97. Fracture patterns were statistically similar according to Mann-Whitney test. It was concluded that customization of fibre posts with diamond burs or paper discs produces acceptable micromorphological changes. The cut of the post with pliers should be avoided. Grounding of the apical portion of fibre posts reduces the flexural strength to acceptable values. Teeth restored with grounded fiber posts have grater fracture strength than teeth restored with intact posts. Grounding of the post facilitates adaptation to root walls and preserves tooth structure.
30

Avaliação da customização por desgaste de pinos pré-fabricados de fibra de vidro / Evaluation of fibre posts submitted to customization of the apical portion

Ana Regina Cervantes Dias 25 January 2012 (has links)
O objetivo deste estudo foi avaliar pinos pré-fabricados de fibra de vidro (White Post DC/FGM) submetidos à customização por desgaste da porção apical. Experimento 1: 5 pinos n. 4 foram divididos em 5 grupos (G) de acordo com o instrumento de desgaste: GA - sem desgaste, GB- mini torno industrial (Dentsply), GC - ponta diamantada n. 3195F (KG Sorensen), GD - disco de lixa de granulação média (Sof-Lex/3M/ESPE), GE- alicate (Tramontina). Observou-se a micromorfologia dos pinos em microscópio eletrônico de varredura (ZEISS/DSM 960). Experimento 2: 60 pinos de diferentes diâmetros foram divididos em 6 grupos: G0 - pinos n. 0,5, G1 - pinos n. 1, G2 - pinos n. 2, G3 - pinos n. 3, G4 - pinos n.4, G5 - pinos n. 4 com terço apical desgastado com discos de lixa até o equivalente ao terço apical dos pinos n. 2. Os pinos foram submetidos ao teste de flexão de 3 pontos na máquina de ensaios universal (Instron 5500 R), conforme ISO 10477. Experimento 3: 20 caninos humanos permanentes sofreram tratamento endodôntico e remoção das coroas clínicas padronizando 15 mm de remanescente radicular. Os dentes foram incluídos em resina acrílica com simulação do ligamento periodontal, receberam férula de 2 mm e foram divididos em 2 grupos: GI - pinos n. 4 cimentados em condutos preparados com broca equivalente ao pino (FGM), GII - pinos n. 4 customizados no terço apical cimentados em condutos preparados com brocas (FGM) equivalentes aos pinos n. 2 em 10 mm e n. 4 em 5 mm. Os pinos foram cimentados com cimento resinoso (Rely X U100/3M/ESPE), os corpos de prova receberam coroas diretas de resina composta (Enforce Core/Dentsply) padronizadas com coras de policarbonato (TDV) e foram submetidos ao teste de resistência à fratura na Instron a 45da ferramenta cilíndrica, com força de 500 N aplicada a 2 mm da incisal na face palatina/lingual, com velocidade de 0,5 mm/min até falha. O padrão de fratura foi classificado em favorável ou desfavorável. Os resultados foram tratados estatisticamente por teste de análise de variância (ANOVA, p<0,05). Os resultados dos testes de flexão e fratura foram respectivamente: G0 - 58,406,40; G1 - 83,959,43; G2- 103,4219,17; G3 - 160,7817,30; G4 - 170,4711,28; G5 - 106,3521,96; GI - 303,0262,21 e GII - 402,81131,97. O padrão de fratura foi tratado por Mann-Whitney que observou semelhança estatística entre os grupos. Concluiu-se que o desgaste de pinos de fibra de vidro com pontas diamantadas ou discos de lixa produz alterações micromorfológicas aceitáveis. O corte com alicate deve ser evitado. A customização por desgaste da porção apical de pinos de fibra de vidro diminui a resistência à flexão a valores aceitáveis. Dentes restaurados com pinos de fibra de vidro customizados por desgaste possuem resistência à fratura superior a dentes restaurados com pinos intactos. A customização por desgaste facilita a adaptação do pino ao conduto radicular e preserva a estrutura dental. / The purpose of this study was to evaluate fibre posts (White Post DC/FGM) submitted to customization of the apical portion. Experiment 1: 5 #4 posts were divided into five groups (G) and submitted to different custom adaptation treatments: GA no surface treatment, GB- industrial shaping tool (Dentsply), GC- #3195 fine diamond bur (KG Sorensen), GD- medium-grain paper discs (Sof-Lex/3M/ESPE), GE pliers (Tramontina). The micromorphology of the posts was observed in a scanning electron microscope (ZEISS/DSM 960). Experiment 2: 60 posts of different diameters were divided into six groups: G0 #0.5 posts, G1 #1 posts, G2 #2 posts, G3 - #3 posts; G4 - #4 posts and G5 #4 posts submitted to custom adaptation of the apical portion with paper discs until the diameter was equivalent to #2 posts. The posts were submitted to a 3 point bending test in a universal testing machine (Instron/5500 R), according to ISO 10477. Experiment 3: 20 freshly extracted permanent healthy human canines with similar size were endodontically treated and the crowns were removed, leaving a remaining root length of 15 mm. The teeth were embedded in acrylic resin with simulation of the periodontal ligament, received a 2 mm ferule and were divided into two groups: G1- 10 #4 posts were cemented into post spaces prepared with #4 drill (FGM) at 10 mm, G2 - 10 #4 customized posts were cemented into root spaces prepared with #2 drill (FGM) at 10 mm and #4 drill (FGM) at 5 mm. The posts were cemented with resin cement (Rely X U100/3M/ESPE), and the teeth received direct crowns of composite resin (Enforce Core/Dentsply), standardized with polycarbonate crowns (TDV). The fracture strength was measured on an Instron, at 45 degrees to the long axis of the tooth, until fracture. The 500 N cylindrical load was applied to the buccal/lingual axis 2 mm below the incisal line, at crosshead speed of 0.5 mm/min. The fracture pattern was observed and classified as favorable or unfavorable. The results were submitted to ANOVA (p<0.05). Flexural strength and resistance to fracture data were, respectively: G0 58.40+6.40; G1 83.95+9.43; G2 103.42+19.17; G3 160.78+17.30; G4- 170.47+11.28; G5 106.35+21.96;GI 303.02+62.21 and GII 402.81+131.97. Fracture patterns were statistically similar according to Mann-Whitney test. It was concluded that customization of fibre posts with diamond burs or paper discs produces acceptable micromorphological changes. The cut of the post with pliers should be avoided. Grounding of the apical portion of fibre posts reduces the flexural strength to acceptable values. Teeth restored with grounded fiber posts have grater fracture strength than teeth restored with intact posts. Grounding of the post facilitates adaptation to root walls and preserves tooth structure.

Page generated in 0.139 seconds