31 |
Understanding and predicting excavation damage in sedimentary rocks: A continuum based approachPerras, Matthew 30 January 2014 (has links)
The most widely accepted approach to long-term storage of nuclear waste is to design and construct a deep geological repository, where the geological environment acts as a natural barrier to radio nuclide migration. Sedimentary rocks, particularly argillaceous formations, are being investigated by many countries because of favorable isolating qualities (laterally continuous and low permeability) and the ability of self-sealing of fractures. Underground construction creates a damage zone around the excavation. The depth away from the excavation surface of the damage zone depends on the rock mass properties, the stress field, and the construction method. This research investigates the fracture development process in sedimentary rocks and evaluates continuum modelling methods to predict the damage zone dimensions.
At the laboratory scale, a complete classification system for samples of carbonate and siliciclastic rocks has been developed, with geotechnical considerations, which when applied narrows the variability of the mechanical properties. Using this system, crack initiation (CI) shows the most uniform range in each class, particularly for mud rocks. Tensile strength was found to be higher for the Brazilian method than Direct method of testing. Brazilian reduction to Direct values was found to be rock type dependent. Laboratory testing results are also influenced by the orientation of bedding.
Bedding and other structures were also found to influence the excavation behaviour as observed at the Niagara Tunnel Project in a mudstone and in excavations in the Quintner limestone of Switzerland. The conceptual stages of damage development and the potential fracture networks in sedimentary rocks are used to summarize the understanding of excavation damage developed in this thesis.
Using a continuum based modelling approach, a set of predictive damage depth curves were developed for the different excavation damage zones. This approach was found to be most sensitive to the tensile strength used as an input. Back analysis of the Niagara Tunnel Project and forward prediction of the excavation damage around a shaft in the Queenston Formation are used to illustrate the importance of this research. The prediction methods were also applied to cut-off design analysis. This research has enhanced the understanding of excavation damage development in sedimentary rocks and provided a methodology to predict the dimensions of the excavation damage zones using a continuum based approach. / Thesis (Ph.D, Geological Sciences & Geological Engineering) -- Queen's University, 2014-01-29 16:08:58.022
|
32 |
The effect of primers on the tensile bond strength between MDX 4-4210 silicone and two acrylic resins (autopolymerizing and light-polymerizing acrylic resin) /Natdhanai Chotprasert, Theerathavaj Srithavaj, January 2006 (has links) (PDF)
Thesis (M.Sc. (Maxillofacial Prosthetics)--Mahidol University, 2006. / LICL has E-Thesis 0019 ; please contact computer services. LIRV has E-Thesis 0019 ; please contact circulation services.
|
33 |
The effect of primers on bond strength of silicones to autopolymerizing acrylic resin) /Doan, Minh Tri, Theerathavaj Srithavaj, January 2006 (has links) (PDF)
Thesis (M.Sc. (Maxillofacial Prosthetics)--Mahidol University, 2006. / LICL has E-Thesis 0019 ; please contact computer services. LIRV has E-Thesis 0019 ; please contact circulation services.
|
34 |
Tensile properties of heat-manipulated stainless steel orthodontic wires a thesis submitted in partial fulfillment ... orthodontics /Ponitz, Robert J. January 1955 (has links)
Thesis (M.S.)--University of Michigan, 1955.
|
35 |
Resistência de união cerâmica - agente cimentante. Teste de micro-tração e análise por microscopia eletrônica de varreduraFaria, Ricardo Pinheiro de [UNESP] 02 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-12-02Bitstream added on 2014-06-13T20:41:45Z : No. of bitstreams: 1
faria_rp_dr_arafo.pdf: 1705909 bytes, checksum: 0b8648d6813e632a7474c2c61b823912 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos deste trabalho foram avaliar a influência de diferentes tempos de condicionamento ácido na resistência de união cerâmica-agente cimentante, por meio do teste de Micro-Tração, bem como análise dos modos de fratura. Foram confeccionados 5 pares de discos de cerâmica de infra-estrutura IPS Empress 2 e divididos aleatoriamente em 5 grupos. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação seqüencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: G1: sem condicionamento ácido; G2: 20 s de condicionamento com ácido fluorídrico a 10%; G3: 40 s e condicionamento com ácido fluorídrico a 10%; G4: 60 s de condicionamento com ácido fluorídrico a 10% e G5: 2 min de condicionamento com ácido fluorídrico a 10%. Os espécimes, aos pares, foram cimentados com um sistema adesivo e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 h a 37°C e, posteriormente, com auxílio de um disco de diamante perpendicular à superfície de união, palitos com 1 mmø de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS 800) e submetidos à análise de variância e teste de Tukey. As médias de resistência foram de 30,20 MPa, 36,19 MPa, 38,72 MPa, 41,43 MPa e 42,53 MPa, respectivamente aos grupos G1, G2 G3 G4 e G5. O grupo G1 apresentou menor resistência média de união do que os demais grupos. O grupo G3 teve comportamento semelhante a G2 e a G4, porém estes dois últimos foram diferentes entre si. Os grupos G4 e G5 promoveram resistências médias semelhantes. Concluímos que o aumento do tempo de condicionamento ácido aumentou os valores de resistência de... . / The purpose of this study was to investigate the effect of different times of acid conditioning on the microtensile bond strength between union-cement and ceramic, and to verify the mode of failure. Five pairs of ceramic disks (IPS Empress 2) were divided, in five groups, by randomized allocation. The bonding surfaces were finished with 600-grit silicon carbide paper. The specimens were nominated at random and submitted to the following treatments before cementation: G1 : without acid etching; G2 : 20 s of etching with 10% hydrofluoric acid; G3 : 40 s of etching with 10% hydrofluoric acid; G4 : 60 s of etching with 10% hydrofluoric acid and G5 : 2 min of etching with 10% hydrofluoric acid. All the pairs were bonded with dual cure resin bonding and dual cure resin cement, according to manufacturer's instructions. The specimens were light-cured and then stored for 48 h at 37°C. Using a diamond disk perpendicular to the bonding interface, 'sticks' with 1.0 mmø cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. It was applied analysis of variance and Tukey test at p<0.05. The means of microtensile bond strength, in MPa, were 30.20, 36.19, 38.72, 41.43 and 42.53, respectively to the groups G1, G2, G3, G4 and G5. Group G1 had the smallest microtensile bond strength and G3 had similar results when compared to G2 and G4, although G2 and G4 were different between themselves. The groups G4 and G5 showed similar means of microtensile bond strength. Conclusions: The higher the time of acid conditioning higher were the values of microtensile bond strength, and the analysis of mode of failure exhibited prevalence of adhesive failure type.
|
36 |
Análise in vitro da resistência adesiva de resinas compostas em cavidades de classe II, através do teste de microtração. Efeito de diferentes técnicas restauradorasCalixto, Abraham Lincoln [UNESP] 22 July 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-07-22Bitstream added on 2014-06-13T20:01:56Z : No. of bitstreams: 1
calixto_al_dr_arafo.pdf: 933718 bytes, checksum: 50e18e9960ea9272e8e8efc853a8ef95 (MD5) / O objetivo deste trabalho foi analisar in vitro a resistência adesiva, em cavidades de classe II, restauradas com resinas compostas, através do teste de microtração . Foram realizadas cavidades padronizadas, de classe II, tipo slot, nas superfícies mesial e distal de 24 dentes terceiros molares humanos e hígidos. Os dentes foram aleatoriamente divididos em 6 grupos com 16 espécimes cada. O procedimento restaurador foi realizado através de técnica de incrementos múltiplos com as resinas compostas P60 (compactável) e Z250 (multiuso), sob efeito de diferentes técnicas restauradoras, a saber: Grupo PT1- adesivo + P60 ; Grupo PT2- adesivo + P60 + ponta fotocondensadora transparente; Grupo PT3- adesivo + flow + P60; Grupo ZT1- adesivo + Z250; Grupo ZT2- adesivo + Z250 + ponta fotocondensadora transparente; Grupo ZT3- adesivo + flow + Z250. O sistema adesivo utilizado foi o Single Bond (3M ESPE). Após as restaurações, os dentes foram armazenados em água destilada em estufa a 37°C, durante 24 horas. A seguir, os dentes foram termociclados por 500 ciclos (5°-55°) e então, seccionados paralelamente ao longo eixo com disco diamantado, no sentido vestíbulo - lingual e mesio - distal, obtendo-se amostras em forma de palitos, com área de secção transversal de 0,50mmøl0,1mmø . Antes do teste de tração, os palitos tiveram suas áreas de união medidas e anotadas, e então, foram fixados pelas suas extremidades ao dispositivo de microtração com um adesivo instantâneo e a seguir, submetidos ao ensaio de tração em máquina de testes universal (MTS) operada a velocidade de 0,5mm/min. Após a fratura, os valores de resistência adesiva foram calculados e expressos em MPa. O modo da fratura no lado de dentina foi classificada individualmente, com lupa estereoscópica com aumento de 40X. Os dados foram submetidos a análise estatística e demonstrou... / The aim of this work was to analyse in vitro of the tensile bond strength in class II cavities, recuperated with composite resins, throught the microtensile bond test. Standardized cavities were prepared, slot type , in the surfaces mesial and distal of 24 humans molars teeth third and health. The restorations procedures were carried out using the technique of multiple increments with P60 and Z250 resin. The teeth were randoly divided in to 6 groups of 16 specimens each, to know: Group PT1- adhesive+P60; Group PT2- adhesive+P60+ transparent photocondenser point; Group PT3-ahesive+flow+P60; Group ZT1-adhesive+Z250; Group ZT2- adhesive+Z250+ transparent photocondenser point; Group ZT3- adhesive+flow+Z250. The adhesive system were utilized Single Bond (3M/ESPE). After the restorations, the teeth were storage in destilled water for 24h at 37°C. After were thermocycled for 500 cycles at preset temperatures of 5° and 55°C, and the teeth were sectioned with a diamond disc, perpendicularly to the adhesive interface in buccal-lingual an mesio-distal directions, being obtained samples in sticks form with cross-sectional areas of 0,5 mmø. Before testing sticks had their measured and logged union areas. The specimens were then attached to a testing apparatus and tensile load was applied by universal machine at a crosshead speed of 0.5mm/min. After the fracture values of the tensile bond strenght were calculated and expressed in MPa. The dentin surfaces surfaces was examined with aid of glass magnifying stereoscopic with 40X, being verifield the way of failures. The results were submitted statistical analysis showed : 1- the largest values of shear bond strenght went to the group PT2, wich associated the resin P60 with the point photocondenser transparent; 2- the groups that you/they the resin flow didn't present... (Complete abstract, click electronic address below)
|
37 |
Influência da dentina bovina e do dispositivo de microtração na resistência de união de sistemas adesivosYamamoto, Lígia Tiaki [UNESP] 01 December 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:36Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-12-01. Added 1 bitstream(s) on 2015-09-17T15:47:33Z : No. of bitstreams: 1
000843329.pdf: 2861252 bytes, checksum: f0dbdf297658ac001c7053032294cbee (MD5) / Este trabalho teve como objetivos: simular em elementos finitos a distribuição de tensão nos dispositivos de microtração Geraldeli e Modificado durante o teste de microtração; avaliar a resistência de união entre a dentina bovina e a resina composta colada em duas direções: Esmalte-Polpa e Polpa-Esmalte, em dois dispositivos para microtração diferentes: Geraldeli e Modificado. Foi criado o modelo de elementos finitos com a geometria externa baseada em um modelo real no software CAD, e simulado as situações experimentais (geometria, carregamento e fixação) e exportado para o software de análise estrutural Ansys. Para o teste de microtração, foram confeccionados blocos de resina composta colados a dentina bovina com dois tipos de adesivos diferentes (convencional e autocondicionante), que foram testados nos dois dispositivos para microtração. Os valores de resistência de união foram tabulados e submetidos a ANOVA 3 fatores (Tipo de dispositivo X Direção da dentina X Tipo de adesivo) e Teste de Tukey (α = 0,05). As falhas de cada grupo foram classificadas em adesivas, mistas e coesivas com o auxílio de estereomicroscópio e MEV. A distribuição de tensão no dispositivo Geraldeli mostra concentração de tensão na região adesiva do palito e distribuída não-uniformemente (isolinhas oblíquas), com áreas de tração na diagonal da interface adesiva; e no dispositivo Modificado a tensão também está concentrada na região adesiva porém distribuída mais uniformemente (isolinhas paralelas), radial à área adesiva. Foram observadas diferenças significativas para a interação entre Dispositivo X Dentina X Adesivo (p = 0,001), Dispositivo X Dentina (p = 0,000), Dentina X Adesivo (p = 0,017). O adesivo e a dentina também tiveram influência nos resultados de microtração (p = 0,013 e 0,000, respectivamente). Para o dispositivo de Geraldeli, o adesivo convencional obteve melhor resistência de união que o... / This project aimed to: simulate in finite element the stress distribution in Geraldeli and Modified's microtensile device during microtensile test; evaluate the bond strength between bovine dentin and composite resin bonded in two ways: enamel-pulp and pulp-enamel tubule directions, in two different devices for microtensile test: Geraldeli and Modified. The external geometry based on a real model was done in CAD software, experimental conditions were simulated (geometry, loading and fixation) and exported to structural analysis software Ansys. For microtensile test, bovine dentin blocks were bonded to composite resin with two different types of adhesives (conventional and self-etching), which were tested on both microtensile devices. The bond strength values were tabulated and subjected to ANOVA 3-WAY and Tukey's test statistical analysis (α = 0,05). Failures in each group were classified as adhesive, cohesive and mixed in stereomicroscope and SEM. The stress distribution in Geraldeli's device shows stress concentration in the adhesive region of the stick and distributed non-uniformly (oblique contours), with tension areas in the diagonal of the adhesive interface; Modified's device show stress concentration in the adhesive region too but more evenly distributed (parallel contours, radial to the adhesive area. Significant differences for the interaction between device device X dentine X adhesive (p = 0.001), device X dentine (p = 0.000), dentin X adhesive (p = 0.017) were observed. The adhesive and dentin were also influenced the results of microtensile test (p = 0.013 and 0.000, respectively). For Geraldeli device, conventional adhesive got better bond strength than the self-etching, in Pulp-Enamel; and Pulp-Enamel way got lower bond strength for the selfetching adhesives. For modified device, there was no statistical difference among the groups
|
38 |
Sistema adesivo universal: influência da técnica de condicionamento e da pressão pulpar com soro fetal bovino ou água deionizada na resistência de união à dentina humanaGonçalves, Lucélia Lemes [UNESP] 15 December 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:46Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-12-15. Added 1 bitstream(s) on 2015-09-17T15:47:16Z : No. of bitstreams: 1
000844444.pdf: 2215824 bytes, checksum: b4f816ee13ee382fcf0bf5de0f4cbd09 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A simulação da pressão pulpar é importante para reprodução das condições in vivo nos testes de resistência adesiva. Esse estudo avaliou a influência da pressão pupar simulada, utilizando soro fetal bovino ou água deionizada, na resistência de união à dentina do sistema adesivo Single Bond Universal (3M ESPE; Brasil Ltda.), in vitro, aplicado sob diferentes formas de condicionamento dentinário, ácido total e autocondicionante, através do teste de microtração. Setenta e dois molares humanos hígidos foram seccionados 1 mm abaixo da junção amelocementária para separação da coroa da porção radicular e seccionados paralelos à superfície oclusal para exposição de 2 mm de espessura de dentina. As amostras foram divididas aleatoriamente em 3 grupos: Grupo controle - sem pressão pulpar (n = 24); Grupo pressão pulpar soro - pressão pulpar com soro fetal bovino (n = 24); Grupo pressão pulpar água - pressão pulpar com água deionizada (n = 24). Em seguida, os espécimes foram divididos em 2 subgrupos (n = 12): Subgrupo condicionamento ácido total - ácido fosfórico 37% + SB Universal; Subgrupo autocondicionante - SB Universal. O sistema adesivo foi aplicado de acordo com a técnica de condicionamento dentinário ácido total ou autocondicionante, sob a simulação da pressão pulpar com 0 ou 15 cm de soro fetal bovino ou água deionizada (durante todo o procedimento restaurador). Os espécimes foram restaurados com a resina composta Filtek Z350 XT (3M ESPE). Após 48 h em água deionizada, os dentes foram seccionados para a obtenção de palitos com área adesiva de 1 mm2, e submetidos ao teste de microtração após 1 dia de armazenamento. A variação da resistência adesiva entre os grupos foi analisada pelos testes estatísticos ANOVA 2-fatores e Tukey (5% de significância). A maior média de resistência adesiva foi apresentada pelo grupo sem pressão pulpar simulada sob condicionamento dentinário.... / The simulation of pulpal pressure is important for reproduction of in vivo conditions in tests of bond strength. This study evaluated the influence of the etching technique and simulated pulpal pressure with fetal bovine serum or deionized water on bond strength to dentin of Universal Single Bond (3M ESPE;. Brazil Ltda) in vitro. Seventy-two healthy human molars were cut 1 mm below the cemento-enamel junction to separate the crown of radicular portion and cut parallel to the occlusal surface for exposure of 2 mm thickness of dentin. Samples were randomly divided into 3 groups: control group - no pulpal pressure (n = 24); pulpal pressure group serum - pulpal pressure with bovine fetal serum (n = 24); pulpal water pressure group - pulpal pressure with deionized water (n = 24). Then, the subjects were divided into 2 subgroups (n = 12): Subgroup total etch - phosphoric acid 37 % + SB Universal; Self-etch subgroup - SB Universal. The adhesive system was applied according to the technique total-etch or self-etch under pressure simulation with pulp 0 or 15 cm bovine fetal serum or deionized water (throughout the restorative procedure). The specimens were restored with composite resin Filtek Z350 XT (3 m ESPE). After 48 h in deionized water, teeth were sectioned for obtaining beans with 1 mm² adhesive area, and subjected to the test,after 1 day of storage. The variation of bond strength between the groups was analyzed by ANOVA 2-way (simulated pulpal pressure and etch technique) and Tukey (5 % of significance). The highest average bond strength was presented by the group without simulated pulpal pressure self-etch (37.25 ± 4.12) and the lowest average by group simulated pulpal pressure with deionized water and self-etch procedure (26.12 ± 6, 46). There was statistically significant difference for the average bond strength of all groups tested without pressure (36.15a), pulpal ...
|
39 |
Influência da dentina bovina e do dispositivo de microtração na resistência de união de sistemas adesivos /Yamamoto, Lígia Tiaki. January 2014 (has links)
Orientador: Rubens Nisie Tango / Banca: Eduardo Bresciani / Banca: Mirela Sanae Shinohara / Resumo: Este trabalho teve como objetivos: simular em elementos finitos a distribuição de tensão nos dispositivos de microtração Geraldeli e Modificado durante o teste de microtração; avaliar a resistência de união entre a dentina bovina e a resina composta colada em duas direções: Esmalte-Polpa e Polpa-Esmalte, em dois dispositivos para microtração diferentes: Geraldeli e Modificado. Foi criado o modelo de elementos finitos com a geometria externa baseada em um modelo real no software CAD, e simulado as situações experimentais (geometria, carregamento e fixação) e exportado para o software de análise estrutural Ansys. Para o teste de microtração, foram confeccionados blocos de resina composta colados a dentina bovina com dois tipos de adesivos diferentes (convencional e autocondicionante), que foram testados nos dois dispositivos para microtração. Os valores de resistência de união foram tabulados e submetidos a ANOVA 3 fatores (Tipo de dispositivo X Direção da dentina X Tipo de adesivo) e Teste de Tukey (α = 0,05). As falhas de cada grupo foram classificadas em adesivas, mistas e coesivas com o auxílio de estereomicroscópio e MEV. A distribuição de tensão no dispositivo Geraldeli mostra concentração de tensão na região adesiva do palito e distribuída não-uniformemente (isolinhas oblíquas), com áreas de tração na diagonal da interface adesiva; e no dispositivo Modificado a tensão também está concentrada na região adesiva porém distribuída mais uniformemente (isolinhas paralelas), radial à área adesiva. Foram observadas diferenças significativas para a interação entre Dispositivo X Dentina X Adesivo (p = 0,001), Dispositivo X Dentina (p = 0,000), Dentina X Adesivo (p = 0,017). O adesivo e a dentina também tiveram influência nos resultados de microtração (p = 0,013 e 0,000, respectivamente). Para o dispositivo de Geraldeli, o adesivo convencional obteve melhor resistência de união que o... / Abstract: This project aimed to: simulate in finite element the stress distribution in Geraldeli and Modified's microtensile device during microtensile test; evaluate the bond strength between bovine dentin and composite resin bonded in two ways: enamel-pulp and pulp-enamel tubule directions, in two different devices for microtensile test: Geraldeli and Modified. The external geometry based on a real model was done in CAD software, experimental conditions were simulated (geometry, loading and fixation) and exported to structural analysis software Ansys. For microtensile test, bovine dentin blocks were bonded to composite resin with two different types of adhesives (conventional and self-etching), which were tested on both microtensile devices. The bond strength values were tabulated and subjected to ANOVA 3-WAY and Tukey's test statistical analysis (α = 0,05). Failures in each group were classified as adhesive, cohesive and mixed in stereomicroscope and SEM. The stress distribution in Geraldeli's device shows stress concentration in the adhesive region of the stick and distributed non-uniformly (oblique contours), with tension areas in the diagonal of the adhesive interface; Modified's device show stress concentration in the adhesive region too but more evenly distributed (parallel contours, radial to the adhesive area. Significant differences for the interaction between device device X dentine X adhesive (p = 0.001), device X dentine (p = 0.000), dentin X adhesive (p = 0.017) were observed. The adhesive and dentin were also influenced the results of microtensile test (p = 0.013 and 0.000, respectively). For Geraldeli device, conventional adhesive got better bond strength than the self-etching, in Pulp-Enamel; and Pulp-Enamel way got lower bond strength for the selfetching adhesives. For modified device, there was no statistical difference among the groups / Mestre
|
40 |
Sistema adesivo universal: influência da técnica de condicionamento e da pressão pulpar com soro fetal bovino ou água deionizada na resistência de união à dentina humana /Gonçalves, Lucélia Lemes. January 2014 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Co-orientador: Taciana Marco Ferraz Caneppele / Co-orientador: Huéder Paulo Moisés de Oliveira / Banca: Eduardo Bresciani / Banca: Ana Cecília Côrrea Aranha / Resumo: A simulação da pressão pulpar é importante para reprodução das condições in vivo nos testes de resistência adesiva. Esse estudo avaliou a influência da pressão pupar simulada, utilizando soro fetal bovino ou água deionizada, na resistência de união à dentina do sistema adesivo Single Bond Universal (3M ESPE; Brasil Ltda.), in vitro, aplicado sob diferentes formas de condicionamento dentinário, ácido total e autocondicionante, através do teste de microtração. Setenta e dois molares humanos hígidos foram seccionados 1 mm abaixo da junção amelocementária para separação da coroa da porção radicular e seccionados paralelos à superfície oclusal para exposição de 2 mm de espessura de dentina. As amostras foram divididas aleatoriamente em 3 grupos: Grupo controle - sem pressão pulpar (n = 24); Grupo pressão pulpar soro - pressão pulpar com soro fetal bovino (n = 24); Grupo pressão pulpar água - pressão pulpar com água deionizada (n = 24). Em seguida, os espécimes foram divididos em 2 subgrupos (n = 12): Subgrupo condicionamento ácido total - ácido fosfórico 37% + SB Universal; Subgrupo autocondicionante - SB Universal. O sistema adesivo foi aplicado de acordo com a técnica de condicionamento dentinário ácido total ou autocondicionante, sob a simulação da pressão pulpar com 0 ou 15 cm de soro fetal bovino ou água deionizada (durante todo o procedimento restaurador). Os espécimes foram restaurados com a resina composta Filtek Z350 XT (3M ESPE). Após 48 h em água deionizada, os dentes foram seccionados para a obtenção de palitos com área adesiva de 1 mm2, e submetidos ao teste de microtração após 1 dia de armazenamento. A variação da resistência adesiva entre os grupos foi analisada pelos testes estatísticos ANOVA 2-fatores e Tukey (5% de significância). A maior média de resistência adesiva foi apresentada pelo grupo sem pressão pulpar simulada sob condicionamento dentinário.... / Abstract: The simulation of pulpal pressure is important for reproduction of in vivo conditions in tests of bond strength. This study evaluated the influence of the etching technique and simulated pulpal pressure with fetal bovine serum or deionized water on bond strength to dentin of Universal Single Bond (3M ESPE;. Brazil Ltda) in vitro. Seventy-two healthy human molars were cut 1 mm below the cemento-enamel junction to separate the crown of radicular portion and cut parallel to the occlusal surface for exposure of 2 mm thickness of dentin. Samples were randomly divided into 3 groups: control group - no pulpal pressure (n = 24); pulpal pressure group serum - pulpal pressure with bovine fetal serum (n = 24); pulpal water pressure group - pulpal pressure with deionized water (n = 24). Then, the subjects were divided into 2 subgroups (n = 12): Subgroup total etch - phosphoric acid 37 % + SB Universal; Self-etch subgroup - SB Universal. The adhesive system was applied according to the technique total-etch or self-etch under pressure simulation with pulp 0 or 15 cm bovine fetal serum or deionized water (throughout the restorative procedure). The specimens were restored with composite resin Filtek Z350 XT (3 m ESPE). After 48 h in deionized water, teeth were sectioned for obtaining beans with 1 mm² adhesive area, and subjected to the test,after 1 day of storage. The variation of bond strength between the groups was analyzed by ANOVA 2-way (simulated pulpal pressure and etch technique) and Tukey (5 % of significance). The highest average bond strength was presented by the group without simulated pulpal pressure self-etch (37.25 ± 4.12) and the lowest average by group simulated pulpal pressure with deionized water and self-etch procedure (26.12 ± 6, 46). There was statistically significant difference for the average bond strength of all groups tested without pressure (36.15a), pulpal ... / Mestre
|
Page generated in 0.0323 seconds