• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 171
  • 110
  • 31
  • 18
  • 14
  • 14
  • 14
  • 13
  • 11
  • 9
  • 5
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 420
  • 420
  • 106
  • 75
  • 69
  • 67
  • 60
  • 59
  • 50
  • 45
  • 43
  • 39
  • 37
  • 37
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Metal-tissue interactions in early stage biocorrosion of metallic stents

Halwani, Dina. January 2007 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2007. / Additional advisors: Peter G. Anderson, Brigitta C. Brott, Jack E. Lemons. Description based on contents viewed Feb. 4, 2008; title from title screen. Includes bibliographical references (p. 69-70).
222

Transient liquid phase bonding of a third generation gamma-titanium aluminum alloy-Gamma Met PX

Butts, Daniel A., Gale, W. F. January 2005 (has links) (PDF)
Dissertation (Ph.D.)--Auburn University, 2005. / Abstract. Vita. Includes bibliographic references.
223

The development of a lightweight electric vehicle chassis and investigation into the suitability of TiA1 for automative applications

Lovatt, Ryan. January 2008 (has links)
Thesis (M.E. Mechanical Engineering)--University of Waikato, 2008. / Title from PDF cover (viewed October 1, 2008) Includes bibliographical references (p. 122-130)
224

Design of lightweight electric vehicles

De Fluiter, Travis. January 2008 (has links)
Thesis (M.E. Mechanical Engineering)--University of Waikato, 2008. / Title from PDF cover (viewed October 2, 2008) Includes bibliographical references (p. 131-136)
225

Thermophysical property and phase transformation determination of gamma-TiAl intermetallics /

Overton, Judith M. January 1900 (has links)
Thesis (M.App.Sc.) - Carleton University, 2006. / Includes bibliographical references (p. 110-113). Also available in electronic format on the Internet.
226

High temperature volatility and oxidation measurements of titanium and silicon containing ceramic materials /

Nguyen, QuynhGiao N. January 2008 (has links)
Thesis (Ph.D.)--Cleveland State University, 2008 / Abstract. Includes bibliographical references (p. 110-111). Electronic full text release has been delayed at the author's request until December 31, 2010.
227

Surface modification of titanium substrates with polymer brushes to control cell adhesion for bioapplications

Raynor, Jenny E. January 2008 (has links)
Thesis (Ph. D.)--Chemistry and Biochemistry, Georgia Institute of Technology, 2009. / Committee Chair: Collard, David M.; Committee Co-Chair: Garcia, Andres J.; Committee Member: France, Stefan; Committee Member: Ragauskas, Arthur; Committee Member: Temenoff, Johnna. Part of the SMARTech Electronic Thesis and Dissertation Collection.
228

Preparação e caracterização de ligas do sistema Ti-Mo contendo oxigênio intersticial para aplicações biomédicas

Nogueira, Renata Abdallah [UNESP] 19 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-04-19Bitstream added on 2014-06-13T19:06:01Z : No. of bitstreams: 1 nogueira_ra_dr_bauru.pdf: 4832696 bytes, checksum: e9a20c5603fd561629f155a1c301899e (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Titânio e suas ligas são empregados em aplicações biomédias, pois possuem excelente biocompatibilidade com o organismo humano, uma excelente resistência à corrosão em meio biológico além de uma ótima resistência mecânica/densidade. Diversas propriedades do titânio comercialmente puro podem ser melhoradas com a adição de elementos substitucionais e intersticiais, e por técnicas de processamentos termomecânicos. o objetivo neste trabalho foi estudar o efeito de oxigênio intersticial presente em ligas do sistema binário. Ti-Mo (5-20% em peso de Mo) em seu comportamento mecânico utilizando ensaios de dureza, módulo de elasticidade dinâmico e ensaio de tração, em cinco condições de estudo: após o forjamento rotativo a quente, tratamento térmico e após dopagem com oxigênio, com três diferentes teores deste elemento. As amostras foram preparadas em forno a arco e caracterizadas por medidas de composição química, análise de gases, difração de raios X, microscopia óptica e eletrônica de varredura, espectroscopia por energia dispersiva e medidas de densidade. Após as dopagens com oxigênio, observou-se um aumento na dureza da liga Ti-5Mo devido ao aumento na fração volumétrica da fase a'. Para a liga Ti-10Mo, os valores após as dopagens permaneceram próximos à condição após tratamento térmico, não ocorrendo variações expressivas. Para as ligas Ti-15Mo, verificou-se uma diminuição na dureza provavelmente devido ao resfriamento rápido realizado após as dopagens com oxigênio. Os valores do módulo de elasticidade da liga Ti-5Mo aumentaram com o aumento da concentração de oxigênio, pois ocorreu um aumento na fração volumétrica da fase a'. Com relação aos valores de módulo de elasticidade da liga Ti-10Mo, não se observam variações significativas devido à adição de oxigênio. Para as ligas... / Titanium and its alloys are used in biomedical applications because they have excellent biocompatibility with human organisms, an excellent corrosion resistance in biological mediums, and great mechanical strength/density. Several properties of commercially pure titanium can be improved by the addition of interstitial and substitutional elements or by thermo-mechanical processing techniques. The purpose of this work is to study the effect of interstitial oxygen present in binary Ti-Mo systemj alloys (5-20% in weight of Mo) on its mechanical behavior, using hardness testing, dynamic elasticity modulus and tensile test on five conditions: after swaging, after heat treatment, and after oxygen doping, with three different levels of this element. The samples were prepared in an arcmelting furnace and were characterized by measures of chemical composition, gas analysis, x-ray diffraction, electron and optical microscopy, energy dispersive spectroscopy, and density measurements. After the doping with oxygen an increase in hardness of the Ti-5Mo alloy due to the increased volumetric fraction of a' phase was observed. For the Ti-10Mo alloy, the values after the doping were similar to those after heat treatment, and no expressive variations occurred. For the Ti-15Mo and Ti-20Mo alloys, there was a decline in hardness, probably due to rapid cooling after the doping with oxygen. The values of the elasticity modulus Ti-5Mo alloy increased with increasing oxygen concentration, because ther was an increase in the volumetric fraction of a' phase. With respect to the values of elasticity modulus of the Ti-10Mo alloy, no significant variations due to the addition of oxygen were observed. For the Ti15Mo and Ti-20Mo alloys, the introduction of oxygen decreased the elasticity modulus, because, with the increase in distance between the atoms, there was... (Complete abstract click electronic access below)
229

Caracterização mecânica, física e química das ligas Ti-35Nb-5Zr e Ti-35Nb-10Zr /

Ribeiro, Ana Lúcia Roselino. January 2008 (has links)
Orientador: Luis Geraldo Vaz / Banca: Carlos Alberto dos Santos Cruz / Banca: Rubens Caram Junior / Resumo: Nas áreas médica e odontológica, a utilização do titânio para a substituição de estruturas biológicas se confirmou a partir do reconhecimento de suas excelentes propriedades. Com o objetivo de atingir melhores propriedades mecânicas, não alterando, porém, sua biocompatibilidade, foi proposto adicionar nióbio e zircônio ao titânio, formulando-se duas ligas metálicas Ti-35%Nb-5%Zr (liga 1) e Ti-35%Nb- 10%Zr (liga 2) (%m/m). As ligas foram caracterizadas por propriedades mecânicas, físicas e químicas. Para a obtenção das ligas foi utilizado um forno de fusão a arco-voltáico com atmosfera inerte, controlada por bomba de vácuo e fluxo de argônio. A análise química das amostras foi realizada por fluorescência de raios X, e a avaliação microestrutural, por microscopia eletrônica de varredura e difratometria de raios X. Os testes mecânicos realizados foram: dureza Vickers, resistência à tração, ciclagem mecânica por tração e análise de fratura. Os resultados permitiram caracterizar a liga 1 como do tipo α+β e a liga 2 como do tipo β. Conclui-se que a liga 1 apresentou maior dureza e menor resistência à tração do que a liga 2. As fraturas, após o teste de tração, foram do tipo dúctil e, após a ciclagem mecânica, foram do tipo mista para ambas as ligas. As características estudadas mostram que as ligas 1 e 2 são promissoras para a fabricação de implantes dentários. / Abstract: In medical and dentistry areas, the use of titanium for the substitution of biological structures has been confirmed since recognition of its excellent properties. With the objective of exploiting better mechanical properties, not altering, however, its biocompatibility, it was intended to add niobium and zirconium to the titanium, being formulated two metallic alloys Ti- 35%Nb-5%Zr (alloy 1) and Ti-35%Nb-10%Zr (alloy 2) (%m/m). The alloys were characterized through mechanical, physics and chemistries properties. For obtaining the alloys an arc-melting furnace was used under inert atmosphere, controlled by vacuum bomb and argon flow. The chemical analysis of the samples was accomplished by X -ray fluorescence, and the microestrutural evaluation by scanning electron microscopy and X-ray diffraction. The performed skilled mechanical tests were: Vickers hardness, tensile strength, mechanical cycling, and fracture analysis. The results allowed characterizing the alloy 1 as α+β type and the alloy 2 as β type. It is found that the alloy 1 presented larger hardness and smaller tensile strength than the alloy 2. The fractures, after the tensile test, were of the ductile type and, after the mechanical cycling, they were of the mixed type for both alloys. The studied characteristics have shown that the alloys 1 and 2 may be promises compounds for manufacture of dental implant. / Mestre
230

Efeito do oxigênio nas propriedades anelásticas da liga Ti-10Mo para aplicação biomédica

Nogueira, Renata Abdallah [UNESP] 25 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-25Bitstream added on 2014-06-13T18:50:40Z : No. of bitstreams: 1 nogueira_ra_me_bauru_prot.pdf: 2628699 bytes, checksum: 548bffb406de71f06f0ab9ae6a52d7c8 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A utilização de biomateriais do reparo do tecido ósseo tem revolucionado a Ortopedia e a Odontologia atuais. Um metal estudado para estas aplicações é o titânio e suas ligas, pois possuem um excelente grau de biocompatibilidade com o organismo humano, uma excelente resistência à corrosão em meio biológico e uma ótima relação resistência mecânica/densidade. Estas propriedades são fortemente influenciadas pela presença de lementos intersticiais e as medidas de atrito interno têm sido muito utilizadas para verificar o comportamento destes elementos em materiais. O objetivo neste trabalho foi estudar o efeito de elementos intersticiais nas propriedades da liga Ti-10Mo (% em peso), por meio de medidas de difração de raios X, microscopia eletrônica e varredura, testes de citotoxidade, corrosão e espectroscopia mecânica. As amostras foram submetidas a tratamentos térmicos de recozimento e dopagem com oxigênio. Os testes de biocompatibilidade mostraram que não houve nenhuma resposta indireta. Os extratos dos materiais não interferiram no desenvolvimento, crescimento e proliferação das células. Foi detectada uma melhora na taxa de corrosão, juntamente com um aumento do potencial de corrosão, com a dopagem do material, características estas interessantes para um biomaterial. Os resultados de espectroscopia mecânica mostraram a presença de uma estrutura de relaxação após a dopagem com oxigênio em torno de átomos dos elementos que compõem a liga. Observou-se que a adição de oxigênio intersticial causou um aumento no módulo de elasticidade, o que é ruim quando se trata de um biomaterial para implantes ortopédicos. / The use of the biomaterials in the repair of the bone tissue has been revolutionizing the Orthopedics and the Odontology. A metal very studied for these applications is the titanium and its alloys, because they possess an excellent corrosion resistance in a biological media and a good relationship mechanical strength/density. These properties are strongly influenced by the presence of interstitial elements and the internal friction measurements have been a lot used to verify the behavior of these interstitial elements in materials. The objective of this work was to study the effect of interstitial elements in the properties of the Ti-10Mo (%in weight) alloy, through X-ray diffraction, scanning electron microscopy, cytotoxicity tests, corrosion and mechanical spectroscopy. The samples were submitted to heat treatments of annealing and oxygen doping. The biocompatibility tests showed that there was not any indirect cytotoxic answer. The extracts of the materials didn't interfere in the development, growth and proliferation of the cells. An increase in the corrosion rate was detected, with an increase of the corrosion potential, with the oxygen doping, interesting for applications as biomaterial. The mechanical spectroscopy results showed the presence of a relaxation structure after the oxygen doping that was attributed mainly to the stress-induced ordering of the oxygen atoms around the atoms that compose the alloy. It was observed an increase in the elasticity with the oxygen doping, what is bad when it is a biomaterial.

Page generated in 0.0226 seconds