• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 8
  • Tagged with
  • 118
  • 118
  • 14
  • 14
  • 12
  • 12
  • 10
  • 10
  • 10
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Sintese de prolactina humana em celulas de ovario de hamster chines (CHO)

SOARES, CARLOS R.J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:05Z (GMT). No. of bitstreams: 1 06777.pdf: 5273885 bytes, checksum: b88f10c3d25adde0595b62adc866d4ee (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
112

Análise compartimental e aspectos dosimétricos aplicados ao colesterol marcado com sup(3)H / Compartimental analysis and dosimetric aspects applied to cholesterol with sup(3)H labeled

OLIVEIRA, ADRIANO dos S. 03 February 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-02-03T11:46:20Z No. of bitstreams: 0 / Made available in DSpace on 2016-02-03T11:46:20Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
113

Sintese de prolactina humana em celulas de ovario de hamster chines (CHO)

SOARES, CARLOS R.J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:05Z (GMT). No. of bitstreams: 1 06777.pdf: 5273885 bytes, checksum: b88f10c3d25adde0595b62adc866d4ee (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
114

Análise compartimental e aspectos dosimétricos aplicados ao colesterol marcado com sup(3)H / Compartimental analysis and dosimetric aspects applied to cholesterol with sup(3)H labeled

OLIVEIRA, ADRIANO dos S. 03 February 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-02-03T11:46:20Z No. of bitstreams: 0 / Made available in DSpace on 2016-02-03T11:46:20Z (GMT). No. of bitstreams: 0 / Doenças cardiovasculares (DCVs) são uma das maiores causas de morte ao redor do mundo, de acordo com a Organização Mundial da Saúde (OMS). Sabe-se que, alterações do nível das lipoproteínas plasmáticas, que são responsáveis pelo transporte do colesterol pela corrente sanguínea, estão relacionadas com o desenvolvimento de doenças cardiovasculares. Por essa razão conhecer os parâmetros biocinéticos das lipoproteínas plasmáticas e quantificá-los é importante para corrigir e aprofundar estudos relacionados às doenças associadas a alterações no nível das lipoproteínas. O objetivo principal deste trabalho é fornecer um modelo biocinético e estimar as doses radiométricas para o 3H-Colesterol, um traçador radioativo empregado em estudos fisiológicos e metabólicos. O modelo utilizado neste trabalho foi baseado em [SCHWARTZ e col., 2004] quanto à distribuição do colesterol pelas lipoproteínas e no modelo gastrointestinal do [ICRP 30, 1979]. As doses distribuídas nos compartimentos do modelo e nos órgãos e tecidos de um adulto padrão descritos no [ICRP 106, 2008] foram calculadas utilizando a metodologia MIRD (Medical Internal Radiation Dose) e a análise compartimental realizada pelo programa computacional Matlab®. Os coeficientes de doses foram estimados para um phantom de um homem padrão (73 kg) descrito no [ICRP 60, 1991]. As doses estimadas tanto para o modelo quanto as estimadas para outros órgãos foram baixas e não ultrapassaram a maior dose obtida que foi no intestino grosso superior, como sendo 46,8 μGy. Esses parâmetros poderão ser utilizados como auxilio em trabalhos que necessitem de pareceres dos comitês de ética, quanto ao uso do 3H-Colesterol como traçador radioativo. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
115

Participação de complexos de lantanídeos entre as fases de reservatório de petróleo

Cíntia Helena de Freitas 15 March 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Traçadores são utilizados na explotação de reservatórios de petróleo para fornecer informações que auxiliam na otimização das operações envolvidas. Esta utilização já é comumente praticada fora do Brasil, sendo os mais empregados os radioativos, que apresentam sobre os compostos químicos as vantagens da simplicidade e sensibilidade de detecção e do custo. Uma possibilidade interessante é representada pelos traçadores ativáveis, que podem ser introduzidos no sistema a estudar no estado inativo e serem posteriormente amostrados e dosados por Ativação Neutrônica. Para esta aplicação os elementos da série dos lantanídeos foram testados, visto que estes oferecem características nucleares adequadas para análise. Os traçadores eficientes serão aqueles que não se atrasem ou se percam por interação com as rochas e/ou fluidos não aquosos presentes no reservatório, ou seja, que possuam elevada solubilidade em fase aquosa, coeficientes de partição nulos com a fase orgânica e que não sejam adsorvidos nas elevadas superfícies específicas disponíveis nas formações microporosas das quais desalojam as gotículas de petróleo. Deste modo foi necessário a complexação e quantificação do rendimento através da técnica de Cromatografia Líquida de Alta Eficiência (CLAE). As técnicas espectrométricas de Ressonância Magnética Nuclear (1H e 13C) e Infravermelho (IV) também foram empregadas para caracterização das espécies formadas. Foram realizados testes com o lantânio (La), o európio (Eu) e o disprósio (Dy) com os ligantes ácidos aminopolicarboxílicos (EDTA-2, DTPA) e tia-dicarboxílicos (C4H6SO4 , C7H12S2O4). Após a quantificação do rendimento e caracterização dos complexos de lantanídeos, concluiu-se que há complexação das espécies ligantes com os lantanídeos estudados. Os complexos obtidos em maior rendimento foram então submetidos a testes que simulam uma possível partição destes com a fase orgânica (Kp) e/ou sólida (Kd) do aqüífero, pela metodologia da Análise por Injeção em Fluxo (Flow Injection Analysis FIA) e por testes em um corpo de prova que simula as condições de fluxo em um reservatório de petróleo. O cálculo da partição determinada por Ativação Neutrônica e Espectrometria de Emissão Atômica com Plasma Indutivamente Acoplado (ICP/AES) apresentou um resultado nulo, o que torna possível a utilização dos respectivos complexos como traçadores ambientais em campo de petróleo. Os testes em corpo de prova evidenciaram uma excelente concordância entre o comportamento dos lantanídeos complexados e do traçador de referência (água tritiada). Um outro teste com a metaloporfirina (MnP) foi realizado como estágio prévio para o desenvolvimento de um novo traçador e os resultados positivos indicaram a viabilidade de sua futura utilização. Foram realizados os mesmos testes que para os complexos de lantanídeos, sendo que as determinações dos coeficientes de partição tanto com a fase orgânica (Kp) como com a fase sólida (Kd) foram efetuadas através da Espectrometria UV-Vis. / Tracers are used in the explotation of petroleum reservoirs in order to obtain information that help to optimize its operations. They are presently used on a routine basis in many countries, and the more often applied are the radiotracers, due to some advantages they have over the chemical tracers, such as the simplicity and the sensitivity of their detection besides the cost factor. One of the most conspicuous applications of tracers to reservoirs production activities refers to the evaluation of the secondary recovery techniques, due to their capability to inform about what happens in between the injection and production wells, differently from the other techniques that provide information only at discrete points. An option of interest for the normally required multiple tracer tests is afforded by activable tracers that can be fed to the system under study in the inactive state and have their samples collected at the exit irradiated and measured by Neutron Activation Analysis. Some of the elements of the lanthanide series that exhibit very high thermal neutron cross sections have been tested for this purpose. A properly performing tracer should not lag behind the liquid flow nor be lost through interactions with the rocks and non aqueous fluids inside the reservoir. This means that they must be quite hydrophilic, and have nearly null partition coefficients so that they are neither adsorbed on the internal surfaces of the rock pores nor migrate to the oil phase. Hence it has been necessary to form complexes of the lanthanide metals with appropriate ligands. Besides, to certify the product and to measure the achieved yield, these complexes had to be analyzed by High Performance Liquid Chromatography (HPLC), by 1H and 13C Nuclear Magnetic Resonance (NMR), and by Infrared Spectrometry (IR). The analyses have confirmed the complexation of the lanthanides processed by a previously selected methodology. Following that the performance of these lanthanide complexes as tracers have been tested in essays that simulate the possibility their partition in the oil phase (Kp) as well as their adsorption (Kd) in the solids inside the reservoir, by means of the Flow Injection Analysis (FIA) technique and of core tests, respectively. Tests have carried with lanthanum, europium and dysprosium, that have been complexed with aminopolicarboxylic acids (EDTA2-, DTPA), and with tiacarboxylic acids (C4H6SO4, C7H12S2O4). The measurement of partition, that has been carried by both Instrumental Neutron Activation Analysis (INAA) and Internal Couple Plasma/Atomic Emission Spectrometry (ICP/AES), evidenced null partition and this qualifies these complexes as oil field tracers. The core tests also displayed an excellent match between the lanthanide complexeds and the reference tracer used (tritiated water). On e other test using metal-porphyrin (MnP) has been performed as a previous stage for the development of a novel tracer and the positive results obtained have shown its feasibility for future applications. This complex has been submitted to the same tests performed with the lanthanides and the measurement of both the water phase and the oil, phase partition coefficients (Kp and Kd, respectively) has been carried using UV-Vis spectrometry.
116

Estudo do efeito da radiacao gama sobre a molecula de tetraciclina relativamente ao seu comportamento como agente complexante e extrator

ANDRADE e SILVA, LEONARDO G. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:26Z (GMT). No. of bitstreams: 1 01387.pdf: 2053886 bytes, checksum: 9c61b3e10e5af0bb9a9a9cb8707260c7 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
117

Estudo do efeito da radiacao gama sobre a molecula de tetraciclina relativamente ao seu comportamento como agente complexante e extrator

ANDRADE e SILVA, LEONARDO G. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:26Z (GMT). No. of bitstreams: 1 01387.pdf: 2053886 bytes, checksum: 9c61b3e10e5af0bb9a9a9cb8707260c7 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
118

Desenvolvimento de um sistema de irradiação para produção de radioisótopos gasosos aplicados em processos industriais / Development of a irradiation system for production of gaseous radioisotopes applied in industrial processes

Cardozo, Nelson X. 02 May 2017 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2017-05-02T11:34:44Z No. of bitstreams: 0 / Made available in DSpace on 2017-05-02T11:34:44Z (GMT). No. of bitstreams: 0 / Dentre as diversas aplicações dos radioisótopos, a utilização dos radiotraçadores é considerada uma das mais importantes, no diagnóstico de funcionamento dos equipamentos de processos, em plantas de indústrias químicas e petroquímicas. Os radiotraçadores são utilizados em procedimentos analíticos para obtenção de dados qualitativos e quantitativos de sistemas, em estudos de transferências físicas e físico-químicas. Na produção de radioisótopos gasosos utilizados como traçadores em processos industriais, destacam-se o 41Ar e 79Kr, gases nobres (inertes) que possuem baixa reatividade com os demais elementos químicos. O 41Ar é um emissor gama de alta energia (1,29 MeV) e apresenta elevada porcentagem de transformações com essa energia, o que resulta em quantidades relativamente pequenas necessárias em relação a outras para uma detecção eficaz, mesmo em componentes com grandes espessuras. Atualmente, a produção de radioisótopos gasosos em reatores nucleares de pesquisa é realizada em pequenas quantidades (bateladas), por meio de ampolas de quartzo contendo o gás natural 40Ar ou 78Kr. Nesse sentido, o objetivo desse estudo é desenvolver um sistema de irradiação capaz de produzir em escala contínua, o radioisótopo gasoso 41Ar, dentre outros, com atividade de 7,4x1011 Bq (20 Ci) por ciclo de irradiação, por meio do Reator IEA-R1 de 4,5 MW, fluxo de nêutrons térmicos médio de 4,71 x 1013 ncm-2s-1, para suprir uma demanda existente em empresas de END e inspeções, e pelo próprio Centro de Tecnologia das Radiações, no IPEN/CNEN-SP. O sistema de irradiação (SI) é constituído por uma cápsula de irradiação em alumínio, linhas de transferência, válvulas agulhas, conexões anilhadas, conectores rápidos, manovacuômetro, sistema de vácuo, dewar de liquefação, blindagem em chumbo, cilindros de armazenamento e transporte (CAT), dentre outros. O SI foi aprovado nos testes de estanqueidade e estabilidade (testes de formação de bolhas, pressurização, evacuação e com equipamento leak detector SPECTRON 600 T). Na produção experimental para obtenção de 1,07x1011 Bq (2,9 Ci) de 41Ar, distribuíram-se dosímetros de alanina em diversos componentes e dispositivos do SI. Além disso, determinaram-se as taxas de exposição na parede da blindagem em chumbo, ao concentrar o gás radioativo liquefeito e no CAT, após a transferência do 41Ar, pelo medidor de radiação portátil Teletector ® Probe 6150 AD-t/H. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0352 seconds