• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 237
  • 114
  • 30
  • 15
  • 14
  • 10
  • 10
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 496
  • 150
  • 117
  • 106
  • 84
  • 81
  • 72
  • 59
  • 58
  • 56
  • 54
  • 51
  • 51
  • 45
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Determinação de gases combustíveis em óleo isolante para transformadores, por meio de aquecimento prévio / Determination of combustible gases in insulating oil for power transformers by previous heating

Dênis Augusto Genaro Gouveia 05 May 2008 (has links)
Os transformadores de potência são alguns dos elementos mais importantes dos sistemas elétricos. A confiabilidade e o bom funcionamento destes equipamentos são vitais para que as companhias de energia forneçam eletricidade com qualidade e segurança. Um dos principais parâmetros que envolvem a normalidade da operação dos transformadores é o estado da isolação interna formada pelo óleo mineral e o papel que cobre as bobinas. Danos nessa isolação resultam na degradação destes dielétricos e, por conseqüência, na diminuição da vida útil dos transformadores. Essa degradação, que advém de processos elétricos, térmicos, ou mesmo mecânicos, geram gases combustíveis cujas quantidades individuais podem indicar o tipo de falha e a gravidade do problema. Desta forma, é importante detectar os principais gases envolvidos. O objetivo deste trabalho é realizar análises e estudos quantitativos da presença de gases inflamáveis dissolvidos no óleo, surgidos através da degradação deste líquido isolante. O cerne deste trabalho está em elaborar ensaios de formação de arco no óleo e, posteriormente, aquecer o fluido para medir a quantidade dos gases combustíveis antes dissolvidos nele. Este estudo visa à melhoria na confiabilidade dos equipamentos projetados para detectar e monitorar o surgimento de gases inflamáveis no interior de transformadores de potência existentes em subestações de companhias de eletricidade. / Power transformers are some of the most important elements of electrical systems. The trustworthiness and the good functioning of this equipment permit power utilities to supply electricity with quality and security. One of the main parameters for transformer\'s operation normality is the state of the internal insulation formed by the mineral oil and the paper that covers the bobbins. Damages in this insulation cause its dielectric degradation and, consequently, the reduction of the equipment useful life. This degradation which originates from electrical, thermal, or even mechanical processes generates chemical products such as gases whose individual amounts may indicate the type of imperfection and gravity of the problem. That\'s why the detection of the main involved gases is important. This work intends to elaborate analyses and studies of the presence of inflammable gases dissolved in oil through the degradation of the insulating liquid. The principal topic of this work is the arc formation elaboration in the oil and later the heating of the oil to measure the amount of gases previously dissolved in it. This study also aims to improve the trustworthiness of the projected equipments in order to detect and monitor the sprouting of existing inflammable gases in the interior of power transformers in substations of power utilities.
342

Conception d'amplificateurs de puissance hautement linéaires à 60 GHz en technologies CMOS nanométriques / Design of highly linear 60GHz power amplifiers in nanoscale CMOS technologies

Larie, Aurélien 31 October 2014 (has links)
Dans le cadre des applications sans fil à 60GHz, l’amplificateur de puissance reste un des composants les plus compliqués à implémenter en technologie CMOS. Des modulations à enveloppe non constante obligent à concevoir des circuits hautement linéaires, conduisant à une consommation statique importante. La recherche de topologies et de techniques de linéarisation viables aux fréquences millimétriques fait l’objet de cette thèse. Dans un premier temps, un état de l’art des différents amplificateurs de puissance à 60GHz est dressé, afin d’en extraire l’ensemble des verrous technologiques limitant leurs performances. Suite à l’analyse des phénomènes physiques impactant les composants passifs, plusieurs structures d’amplificateurs élémentaires sont conçues dans les technologies 65nm et 28nm Bulk. Les topologies les plus pertinentes sont déduites de cette étude. Enfin, deux amplificateurs intégrant des techniques de combinaison de puissance et de linéarisation sont implémentés dans les technologies 65nm et 28nm FD-SOI. Ces deux circuits présentent les plus hauts facteurs de mérite ITRS publiés à ce jour. Le circuit en 28nm FD-SOI atteint en outre le meilleur compromis linéarité/consommation de l’état de l’art. / The CMOS 60GHz power amplifier (PA) remains one of the most design-challenging components. Indeed, a high linearity associated with a large back-off range are required due to complex modulated signals.In this context, this work focuses on the design of architectures and linearization techniques which are usable at millimeter-wave frequencies. First, a CMOS PA state of the art is presented to define all bottlenecks. Then, the physical phenomena impacting on passive device performances are described. Elementary PAs are implemented in CMOS 65nm and 28nm Bulk and the most suitable topologies are selected. Finally, two highly linear circuits are designed in 65nm Bulk and 28nm FD-SOI. They achieve the highest ITRS figures of merit reported to this day. In addition, the 28nm FD-SOI PA exhibits the best linearity/consumption tradeoff.
343

Modelling the transient response of windings, laminated steel coresand electromagnetic power devices by means of lumped circuits : With special reference to windings with a coaxial insulation system

Holmberg, Pär January 2000 (has links)
<p>Electromagnetic transients impinging on electromagnetic power devices - such as electric machines, transformers and reactors - can stress the design severely. Thus the magnitudes of the transients are often decisive for the design of the devices. Further, the operation of a device can be transient in itself. This is the case for the explosive magnetic flux compression generator (EMG) and a ferromagnetic actuator. </p><p>Models are presented that are mainly intended for transients in the millisecond range and faster. Hence, eddy currents and the related skin and proximity effect become significant in windings, magnetic cores and in the armatures of the devices. These effects are important for, e.g., the damping of the transients. Further, the displacement current in the insulation of the winding is significant. It changes the response of the windings dramatically, as it manifests the finite velocity of propagation of the electromagnetic fields. Under such circumstances, reflections and excited resonances can make the transient voltage and current distribution highly irregular. </p><p>Induced voltages are modelled with self and mutual inductances or reluctances combined with winding templates. The displacement currents are modelled with capacitances or coefficients of potential. Cauer circuits and their dual form are used to model eddy currents in laminated cores and in conductors. The Cauer circuit enables one to consider hysteresis and the non-linear response of a magnetic core. It is also used to model the eddy currents in the moving armature of an EMG. </p><p>A set-up is presented that can be used to study the transient voltage and the current distribution along a coil. </p><p>The transient response of coaxially insulated windings is analysed and modelled in detail. A lumped circuit model is developed for a coil, Dryformer<sup>TM</sup> - the new high-voltage transformer - and Powerformer<sup>TM</sup>, the new high-voltage generator. An alternative model, a combined lumped circuit and FEM model, is presented for a coaxially insulated winding in two slot cores.</p>
344

Modelling the transient response of windings, laminated steel coresand electromagnetic power devices by means of lumped circuits : With special reference to windings with a coaxial insulation system

Holmberg, Pär January 2000 (has links)
Electromagnetic transients impinging on electromagnetic power devices - such as electric machines, transformers and reactors - can stress the design severely. Thus the magnitudes of the transients are often decisive for the design of the devices. Further, the operation of a device can be transient in itself. This is the case for the explosive magnetic flux compression generator (EMG) and a ferromagnetic actuator. Models are presented that are mainly intended for transients in the millisecond range and faster. Hence, eddy currents and the related skin and proximity effect become significant in windings, magnetic cores and in the armatures of the devices. These effects are important for, e.g., the damping of the transients. Further, the displacement current in the insulation of the winding is significant. It changes the response of the windings dramatically, as it manifests the finite velocity of propagation of the electromagnetic fields. Under such circumstances, reflections and excited resonances can make the transient voltage and current distribution highly irregular. Induced voltages are modelled with self and mutual inductances or reluctances combined with winding templates. The displacement currents are modelled with capacitances or coefficients of potential. Cauer circuits and their dual form are used to model eddy currents in laminated cores and in conductors. The Cauer circuit enables one to consider hysteresis and the non-linear response of a magnetic core. It is also used to model the eddy currents in the moving armature of an EMG. A set-up is presented that can be used to study the transient voltage and the current distribution along a coil. The transient response of coaxially insulated windings is analysed and modelled in detail. A lumped circuit model is developed for a coil, DryformerTM - the new high-voltage transformer - and PowerformerTM, the new high-voltage generator. An alternative model, a combined lumped circuit and FEM model, is presented for a coaxially insulated winding in two slot cores.
345

Modeling And Design Of Iron-core Shunt Reactors With Discretely Distributed Air-gaps

Donuk, Atilla 01 September 2012 (has links) (PDF)
In this research work detailed parallel and series equivalent circuits of a gapped iron-core shunt reactor with discretely distributed gaps are derived. The validity of the recommended equivalent circuits is verified by Finite Element Analysis and laboratory tests. Effects of fringing flux and discretely distributed gaps on inductance parameters and reactor losses are also investigated. Moving Strip Method for discretely distributed gapped shunt reactors is recommended. Two design procedures for shunt reactor with discretely distributed gaps are developed within the scope of this thesis. A simple and practical design approach is also developed which does not need any Finite Element Analysis software. This practical method is very useful for design engineers and researchers. The results of practical design approach are shown to be in good agreement with Finite Element Analysis and experimental work.
346

50 kVA eller 100 kVA : En teknisk och ekonomisk jämförelse av distributionstransformatorer / 50 kVA or 100 kVA : A technical and economic comparison of distribution transformers

Andersson, Carl Fredrik January 2010 (has links)
Rapporten utreder om distributionstransformatorer med märkeffekten 50 kVA i Vattenfall Eldistribution AB:s elnät kan avskaffas till förmån för märkeffekten 100 kVA. Transformatorer med märkeffekten 50 kVA förekommer vid nedtransformering av spänningen från 22 kV och 11 kV till hushållens huvudspänning 0,4 kV. 50 kVA-transformatorer skiljer inte särskilt mycket från transformatorer med den högre märkeffekten i fråga om storlek och pris, och de bedöms kunna bytas ut utan större praktiska svårigheter. Fördelen med 100 kVA är att de elektriska belastningsförlusterna blir lägre i och med den högre märkeffekten. Dessutom innebär ett byte vissa elkvalitetsförbättringar. Nackdelarna med 100 kVA är att de elektriska tomgångsförlusterna är högre och att inköpspriset är högre än för 50 kVA. I övrigt kan kostnaderna likställas för de två alternativen. Endast kostnader för aktiva effektförluster berördes i rapporten då de ekonomiska kostnaderna för reaktiva effektförluster kunde försummas för de aktuella transformatorerna. För att nå ett svar på frågan om det kan vara lönsamt att avskaffa 50 kVA-transformatorerna studerades fem verkliga fall i Vattenfalls svenska elnät. Dessutom studerades eventuella elkvalitetsvinster med ett byte. Svaret blev att inte för något av de fem studerade fallen var det lönsamt med ett byte till 100 kVA-transformator. Rörande elkvalitetsaspekten blev svaret att ett byte visserligen innebär en skillnad men att andra faktorer oftast har större betydelse. Rapportens rekommendation blev att behålla 50 kVA-transformatorn i distributionsnätet.
347

Development Of An Electrical Machines Analysis And Optimum Design Software Package

Goynuk, Yilmaz 01 June 2008 (has links) (PDF)
In this study, three different programs are developed for the analysis of the three-phase induction motor, single-phase capacitor type induction motor and switched reluctance motor. The programs are developed by using Pascal and C++ programming languages. In the performance calculations of motors, analytical methods are used and these methods are tested for accuracy. These programs have also capabilities to design an optimum motor, which meets a set of performance, material and manufacturing constraints while minimizing the weight or any other defined objective function. In addition, in this study, an optimization tool is used to obtain an appropriate optimization method for the design of different types of motors. The software is tested over different commercial motors. The results illustrates that the performance calculations and optimization approach of the programs lead to good results.
348

Comparison Of Axial Flux And Radial Flux Brushless Dc Motor Topologies For Control Moment Gyroscope Wheel Applications

Yilmaz, Kurtulus 01 May 2009 (has links) (PDF)
In this thesis axial flux and radial flux brushless dc motors will be studied as a drive motor for the control of moment gyroscope wheel. Design equations for axial flux and radial flux brushless dc motor topologies will be reviewed. Based on these equations radial and axial flux motors with different number of poles will be designed that meet control moment gyroscope wheel application requirements. The results will be evaluated in terms of efficiency, torque/mass and torque/volume, and suitability for the control moment gyroscope application.
349

Measurement Of Brushless Dc Motor Characteristics And Parameters And Brushless Dc Motor Design

Sahin, Ilker 01 January 2010 (has links) (PDF)
The permanent magnet motors have become essential parts of modern motor drives recently because need for high efficiency and accurate dynamic performance arose in the industry. Some of the advantages they possess over other types of electric motors include higher torque density, higher efficiency due to absence of losses caused by field excitation, almost unity power factor, and almost maintenance free construction. With increasing need for specialized PM motors for different purposes and areas, much effort has also gone to design methodologies. In this thesis a design model is developed for surface PM motors. This model is used with an available optimization algorithm for the optimized design of a PM motor. Special attention is paid to measurement of parameters of a sample PM motor. As a result of this study, an effective analytical model with a proven accuracy by measurement results is developed and applied in a design process of a surface PM motor. Parametric and performance results of analytical model and tests have been presented comparatively. A prototype motor has been realized and tested.
350

Calibration Of Conventional Measurement Transformers Against Harmonic Components By Using Field Measurements Of Optical Transducers And Resistive-capacitive Voltage Transformers

Turkmen, Coskun Aziz 01 June 2010 (has links) (PDF)
It is known from the literature that conventional voltage and current transformers measure inaccurate values for voltage and current harmonics which are parts of power quality. Maximum bandwidth of conventional current transformers, which are used in electricity transmission and distribution systems, is 1.5-2 kHz and it is lower for conventional voltage transformers. Also, it is known that / voltages in some frequency spectrum are measured higher and voltages in another frequency spectrum are measured lower by the conventional voltage transformers. Furthermore, because of the phase shift of fundamental component caused by the conventional current and voltage transformers, losses and efficiency can not be calculated accurately. In this work, through the simultaneous measurements taken at the same feeder by both conventional transformers and new technology measurement transformers / amplitude and phase shift errors which are caused by conventional transformers depending on frequency and so harmonics, are examined and evaluated. Amplitude coefficients and phase shifts are determined for different types of conventional transformers to be able to calibrate measurement deviation. Through this work, measured data by conventional transformers will be accurate and realistic in terms of harmonic components. This matter is important to determine whether the accurate limits which will be set in the future possibly concerning with harmonics and interharmonics, are surpassed or not / also for punitive sanction.

Page generated in 0.0163 seconds