• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 65
  • Tagged with
  • 65
  • 65
  • 64
  • 34
  • 34
  • 28
  • 28
  • 26
  • 21
  • 16
  • 11
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avalia??o histol?gica do cimento de fosfato de c?lcio (CFC) refor?ado por fibras implantado supra-corticalmente em f?mur de ratos

Oliveira, Taiane Coutinho de 17 December 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:35Z (GMT). No. of bitstreams: 1 422268.pdf: 14833302 bytes, checksum: 1b71642b280aa5b7984729b688fbd92e (MD5) Previous issue date: 2009-12-17 / Este estudo analisa histologicamente o efeito do Cimento de Fosfato de C?lcio (CFC) refor?ado com fibras de n?ilon, carbono e polipropileno utilizado como implante supra-cortical em f?mur de ratos. Foram utilizados 20 ratos Wistar, machos, com cerca de 300g cada. Sendo confeccionadas placas de CFC com fibras, no tamanho de 2 mm de espessura por 6 mm de di?metro, os quais foram aparafusados no f?mur dos animais. E estes foram eutanasiados em 30, 60, 90 e 120 dias ap?s o implante sendo as pe?as removidas e submetidas ao processo de rotina para confec??o de l?minas, coradas com Hematoxilina e Eosina. Foram avaliados nos diferentes tempos a biocompatibilidade, o grau de reabsor??o do material e a sua capacidade de osteocondu??o. Em todos os tempos estudados os cortes histol?gicos revelam forma??o de tecido conjuntivo denso, pouco celularizado, apresentando discretamente vascularizado e discreto infiltrado inflamat?rio mononuclear. No entorno do implante, observam-se discretas ?reas de reabsor??o, e indu??o de hialiniza??o das fibras col?genas perif?ricas. O tecido apresenta inclus?o do material do implante. Aos 120 dias chama a aten??o a forma??o de material oste?ide, O grau de reabsor??o ?ssea na periferia do implante foi menor n?o apresentando signific?ncia estat?stica. Podendo-se concluir que: O CFC com fibras ? biocompat?vel, promove a osteocondu??o e neoforma??o ?ssea contornando o cimento. O CFC com fibras, na forma de placas pr?-fabricadas ? adequado para ser utilizado como implante e substituto ?sseo, dentro dos par?metros deste experimento.
62

Avalia??o histol?gica, tomogr?fica e f?sica do efeito da LLLT na distra??o osteog?nica em mand?bulas de coelhos

Kreisner, Paulo Eduardo 30 September 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:38Z (GMT). No. of bitstreams: 1 423502.pdf: 5239440 bytes, checksum: 32e82b4251252353febf2ca10f052662 (MD5) Previous issue date: 2009-09-30 / Esta pesquisa teve como objetivo avaliar, por m?todos histol?gicos, tomogr?ficos e f?sicos, o efeito do laser de baixa pot?ncia (LLLT 830 nm) no osso neoformado em mand?bulas de coelhos submetidas ? fratura, sem ou com distra??o osteog?nica (DO). Foram utilizados 10 coelhos para as an?lises histol?gicas (quatro para o grupo controle e seis para o experimental) al?m de cinco coelhos para as an?lises tomogr?ficas e f?sicas (um n?ofraturado, n?o-distra?do e sem irradia??o laser; um fraturado, n?o-distra?do e sem irradia??o laser; um fraturado, n?o-distra?do e com irradia??o laser; um fraturado, distra?do e sem irradia??o laser; um fraturado, distra?do e com irradia??o laser). Para os coelhos que sofreram alongamento ?sseo por DO foi adotado o seguinte protocolo: lat?ncia tr?s dias, ativa??o sete dias 0,7mm/d, e consolida??o 10 dias. Para os animais irradiados, utilizou-se o laser infravermelho (GaAl)As (J=830 nm, 40 mW) com o seguinte protocolo: dose pontual de 10 J/cm2, diretamente sobre o s?tio ?sseo submetido ? fratura e/ou DO, no per?odo de consolida??o ?ssea, respeitando-se intervalos de 48 horas. O percentual do osso neoformado foi maior no grupo com laser (57,89%) do que no controle (46,75%), p=0,006, conforme observado na an?lise histol?gica. A an?lise tomogr?fica revelou aumento da densidade, medida em Unidades Hounsfield (HU), dos ossos fraturados que foram irradiados com laser. Com rela??o ?s propriedades f?sicas, pareceu n?o haver grandes diferen?as entre os grupos que sofreram fratura. Nos ossos submetidos ? DO, o laser n?o promoveu altera??o da nanodureza, mas modificou os valores do m?dulo de elasticidade, na amostra estudada.
63

Avalia??o da dureza e do m?dulo de elasticidade do osso mandibular submetido ? distra??o osteog?nica e ? LLLT : estudo preliminar em ovelhas

Freddo, Angelo Luiz 28 June 2010 (has links)
Made available in DSpace on 2015-04-14T13:29:39Z (GMT). No. of bitstreams: 1 424484.pdf: 12584409 bytes, checksum: ce100d293e186ae476b96a04abe84099 (MD5) Previous issue date: 2010-06-28 / Introdu??o: A distra??o osteog?nica ? um processo terap?utico para induzir neoforma??o tecidual entre superf?cies ?sseas vascularizadas, por meio de uma for?a lenta e progressiva de tra??o, atrav?s de aparelhos funcionais. Objetivos: Validar a utiliza??o dos testes de nanoindenta??o em pesquisas com modelo experimental n?o humano, a fim de conhecer a qualidade do osso mandibular neoformado em ovelhas submetidas ? distra??o osteog?nica e ? terapia a laser de baixa pot?ncia (LLLT), baseado nos valores de dureza e m?dulo de elasticidade. Complementarmente, objetiva-se conhecer o momento mais ben?fico para irradia??o do laser, se na fase de lat?ncia/ativa??o ou matura??o. Ademais, foram realizadas tomografias computadorizadas para avaliar a dimens?o de osso neoformado e verificar poss?veis contra??es desse alongamento. Contexto de Pesquisa: A nanobiotecnologia ? um campo emergente da ci?ncia e da tecnologia que tem o potencial para transformar radicalmente, por meio de novos conhecimentos, os crit?rios atualmente utilizados para conhecer a qualidade do osso formado por distra??o osteog?nica. Materiais e M?todos: Cinco ovelhas foram utilizadas e nelas instalados distratores extra-bucais, com intuito de neoformar 1,5 cm de osso em 60 dias de observa??o, sendo que os distratores eram removidos aos 50, 40 e 33 dias de p?soperat?rio. Quatro animais foram irradiados com LLLT infravermelho (830 ŋm), tendo recebido oito aplica??es, a cada 48 horas, com tr?s pontos de 5J/cm2 e pot?ncia de 50mW, em diferentes per?odos terap?uticos; o quinto foi o controle, sem tratamento LLLT. As pe?as ?sseas foram submetidas a testes de nanoindenta??o para aferir m?dulo de elasticidade e dureza das amostras e a tomografias computadorizadas para avaliar a contra??o ?ssea. Resultados: A LLLT quando utilizada na fase de matura??o do osso, promoveu aumento da dureza e do m?dulo de elasticidade. Por outro lado, os animais irradiados com LLLT durante o per?odo de lat?ncia/ativa??o apresentaram menores valores de dureza e m?dulo de elasticidade. A an?lise tomogr?fica complementar demonstrou que, nos animais com manuten??o do distrator por 33 dias, ocorreu contra??o do osso neoformado. Conclus?es: A nanoindenta??o ? um teste capaz de captar as m?nimas altera??es do metabolismo ?sseo e, portanto, uma importante ferramenta na aferi??o da qualidade do osso em procedimentos de distra??o osteog?nica. A LLLT ? mais ben?fica quando aplicada no per?odo de matura??o do osso, pois promove aumento da dureza e do m?dulo de elasticidade. O per?odo de consolida??o ?ssea com perman?ncia do distrator deve ser de, no m?nimo, tr?s semanas, a fim de prevenir contra??o do tecido ?sseo alongado.
64

Horm?nio do crescimento no processo de osseointegra??o de implantes de tit?nio: estudo experimental e revis?o de literatura / Growth hormone on the osseointegration process of titanium implants: an experimental study and review of literature

Abreu, Marcelo Emir Requia 26 October 2011 (has links)
Made available in DSpace on 2015-04-14T13:30:04Z (GMT). No. of bitstreams: 1 435511.pdf: 4163986 bytes, checksum: 37629882e85d83ed66d26ed9bed14b82 (MD5) Previous issue date: 2011-10-26 / In order to accelerate and improve the quality of the osseointegration process has recently been given emphasis to growth factors. Thus, this thesis was aimed to evaluate the use of growth hormone (GH) on osseointegration of titanium implants. This thesis is composed of two papers, the first chapter is a review of literature on the use of growth factors, and, in particular GH in the process of bone repair. The second chapter is an experimental study to evaluate the topical use of rhGH in the osseointegration of nanotexturized titanium implants inserted in the tibia of rabbits. We used 14 animals randomly divided into rhGH-treated group and control group. In the rhGH-treated group was administered 1 IU of rhGH in surgical defect immediately before the placement of each implant. In the control group was not used rhGH. Each animal received two implants in the left tibia. The animals were sacrificed at 14 and 42 days after surgery. The peri-implant regions were avaluated by transmission and reflection on optical microscopy (OM), to pull out biomechanical testing of implants and scanning electron microscopy (SEM). In all analyzes the rhGH-treated groups showed better performance than the control groups, especially at 14 days. MO at 14 days in the rhGH-treated group have histological characteristics of proliferative repair phase with new bone formation and also marked cortical reaction from the endosteum and periosteum and at 42 days, the bone tissue has a lamellar appearance. The control group at 14 days also has characteristics of the inflammatory and moderate proliferative new bone formation, and with 42 days the new bone does not have lamellar characteristics. In the pull-out testing of the rhGH-treated group showed tension of 59.26N/cm2 and 29.69 N/cm2 at 14 and 42 days respectively. The control group showed tension of 33.88 N/cm2 and 25.99 N/cm2 respectively. The implants analyzed in the SEM showed in the rhGH-treated group at 14 days greater amount of bone attached, but at 42 days there were no differences between groups. The findings in this experiment corroborate the literature, which observed that rhGH increases the speed and amount of newly peri-implanted bone, especially in the early stages of bone repair. Thus, this thesis concludes that topical application of rhGH in the region peri-implant area induces new bone formation. / Com o intuito de acelerar e melhorar a qualidade do processo de osseointegra??o, recentemente tem sido dado ?nfase aos fatores de crescimento. Logo, foi objetivo dessa Tese avaliar o emprego do horm?nio do crescimento (GH) na osseointegra??o de implantes de tit?nio. Esse trabalho ? composto de dois artigos, o primeiro artigo ? uma revis?o de literatura sobre o emprego dos fatores de crescimento, e, em especial o GH, no processo de reparo do tecido ?sseo. O segundo artigo ? um estudo experimental no qual se avaliou o uso t?pico do rhGH no processo de osseointegra??o de implantes de tit?nio nanotexturizados inseridos na t?bia de coelhos. Foram utilizados 14 animais divididos aleatoriamente em grupo teste e controle. No grupo teste foi aplicado 1 IU de rhGH no defeito cir?rgico imediatamente antes da coloca??o de cada implante. No grupo controle n?o foi aplicado o rhGH. Cada animal recebeu 2 implantes na t?bia esquerda. Os animais foram sacrificados em 14 e 42 dias depois da cirurgia. As regi?es periimplantares foram submetidas ? microscopia ?ptica (MO) de transmiss?o e de reflex?o, e os implantes ao ensaio biomec?nico de pull out e a microscopia eletr?nica de varredura (MEV). Em todas as an?lises realizadas o grupo teste apresentou desempenho superior ao controle, principalmente aos 14 dias. Na MO aos 14 dias o grupo teste possu?a caracter?sticas histol?gicas da fase proliferativa do reparo com acentuada neoforma??o ?ssea e tamb?m a forma??o de uma esp?cie de calo ?sseo sobre a cortical ?ssea externa, e aos 42 dias o tecido ?sseo possu?a aspecto lamelar. O grupo controle aos 14 dias possu?a ainda caracter?sticas da fase inflamat?ria e proliferativa com moderada neoforma??o ?ssea, e aos 42 dias o tecido ?sseo neoformado ainda n?o possu?a caracter?sticas lamelares. No ensaio de pull-out o grupo teste apresentou tens?o de 59,26 N/cm2 e 29,69 N/cm2 aos 14 e 42 dias respectivamente, enquanto o grupo controle apresentou tens?o de 33,88 N/cm2 e 25,99 N/cm2 aos 14 e 42 dias, respectivamente. Os implantes analisados no MEV demonstraram no grupo teste aos 14 dias maior quantidade de tecido ?sseo aderido, por?m aos 42 dias n?o se observaram diferen?as entre os grupos. Os achados no experimento corroboram com a literatura, em que se observa que o rhGH aumenta a velocidade e quantidade de osso periimplantar neoformado, principalmente em est?gios iniciais do reparo ?sseo. Com base na revis?o de literatura pesquisada e com os resultados do presente experimento, conclue-se que a aplica??o t?pica de rhGH na regi?o periimplantar acelera o processo de neoforma??o ?ssea. O grupo controle aos 14 dias possu?a ainda caracter?sticas da fase inflamat?ria e proliferativa com moderada neoforma??o ?ssea, e aos 42 dias o tecido ?sseo neoformado ainda n?o possu?a caracter?sticas lamelares. No ensaio de pull-out o grupo teste apresentou tens?o de 59,26 N/cm2 e 29,69 N/cm2 aos 14 e 42 dias respectivamente, enquanto o grupo controle apresentou tens?o de 33,88 N/cm2 e 25,99 N/cm2 aos 14 e 42 dias, respectivamente. Os implantes analisados no MEV demonstraram no grupo teste aos 14 dias maior quantidade de tecido ?sseo aderido, por?m aos 42 dias n?o se observaram diferen?as entre os grupos. Os achados no experimento corroboram com a literatura, em que se observa que o rhGH aumenta a velocidade e quantidade de osso periimplantar neoformado, principalmente em est?gios iniciais do reparo ?sseo. Com base na revis?o de literatura pesquisada e com os resultados do presente experimento, conclue-se que a aplica??o t?pica de rhGH na regi?o periimplantar acelera o processo de neoforma??o ?ssea.
65

An?lise do efeito sist?mico da LLLT no processo de reparo de feridas em dorso de ratos

Rodrigo, Simone Marja 03 December 2007 (has links)
Made available in DSpace on 2015-04-14T13:29:16Z (GMT). No. of bitstreams: 1 399342.pdf: 2962261 bytes, checksum: df6def9f1b7027463673827eb8a6cd76 (MD5) Previous issue date: 2007-12-03 / Este estudo teve por objetivo avaliar, por meio de an?lise histol?gica, a cicatriza??o por segunda inten??o de ferimentos em pele de ratos submetidos, direta e indiretamente, ? radia??o com laser vermelho, infravermelho e a associa??o de ambos. Para tanto, foram empregados 36 ratos machos da linhagem Wistar, com peso entre 200 a 250 gramas, distribu?dos aleatoriamente em quatro grupos: controle, laser vermelho, laser infravermelho e laser vermelho e infravermelho, al?m de tr?s subgrupos de acordo com o per?odo de observa??o dos animais. Em cada animal, realizaram-se tr?s ferimentos na regi?o dorsal, padronizando-se, nos grupos experimentais, que aqueles mais pr?ximos da cabe?a seriam irradiados. Para a avalia??o da rea??o tecidual e da cicatriza??o dos ferimentos, tr?s animais de cada grupo foram mortos nos per?odos de tr?s, cinco e sete dias ap?s a realiza??o dos procedimentos cir?rgicos. O protocolo de irradia??o foi estabelecido com intervalos de 48 horas, iniciando-se imediatamente ap?s a cirurgia. Para an?lise histol?gica, executouse o processamento de rotina para a t?cnica de HE. Os resultados obtidos demonstraram a a??o sist?mica do laser, comparando-se os ferimentos cut?neos diretamente irradiados com os do grupo controle. A associa??o dos lasers resultou no mais evidente efeito sist?mico em processo de reparo tecidual, neste experimento.

Page generated in 0.0382 seconds