• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 30
  • 30
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

HAND-ARM VIBRATION EXPOSURE MONITORING WITH SKIN TEMPERATURE AND PHOTOPLETHYSMOGRAPHY

Qin, Dong 02 June 2017 (has links)
No description available.
22

Le rôle des sulfates de sodium dans l’altération des pierres du patrimoine bâti : méthodes indirectes d'identification pour l'approche expérimentale / The role of sodium sulfate in the stones weathering of heritage building : indirect methods of identification for the experimental approach

Denecker, Mélanie 20 June 2014 (has links)
Les sulfates de sodium sont admis comme étant les sels les plus destructeurs pour les pierres naturelles et autre matériaux poreux. Les processus de cristallisation de ces sels demeurent encore mal compris, plus particulièrement les relations entre l'heptahydrate (SS7, Na2SO4-7H2O) et la mirabilite (SS10, Na2SO4-10H2O). L'heptahydrate, métastable, a longtemps été négligée dans les travaux scientifiques portant sur l'altération saline jusqu'à récemment, et son rôle dans l'altération des roches n'est toujours pas établi à ce jour. Afin de mieux comprendre le rôle des différentes phases dans l'altération, il est important de pouvoir identifier quelle phase cristallise sous des conditions environnementales spécifiques. La cristallisation du sel se produit le plus souvent dans les matériaux poreux où les processus de cristallisation ne peuvent pas être observés directement in situ. Dans cette étude, nous utilisons le suivi de la température pour détecter et identifier la cristallisation des hydrates au cours de cycles de refroidissement/chauffage d'une solution de sulfate de sodium et de l'échantillon de calcaire saturé de cette même solution. En parallèle, d'autres approches expérimentales consistent à mesurer la réponse électrique et élastique des processus de cristallisation / dissolution se produisant dans le milieu poreux. Ces méthodes permettent d'identifier les différentes transitions de phases se produisant au cours de cycles de température et peuvent être utilisées dans des études expérimentales de vieillissement accéléré, afin d'estimer le rôle respectif des différents hydrates de sulfate de sodium dans l'altération des pierres par les sels. / Sodium sulfates are well known to be the most damaging salts in building materials and rocks. The crystallization processes of sodium sulfates are not completely understood, and more specifically the transition between the heptahydrate (SS7, Na2SO4-7H2O) and the mirabilite (SS10, Na2SO4-10H2O). The metastable heptahydrate has long been neglected in scientific works on salt damage until recently, and its role in rock weathering has not been established so far. In order to better understand the role of the different phases in damaging process, it is important to be able to identify which phase crystallizes under specific environmental conditions. Unfortunately, salt crystallization occurs very often within porous material and crystallization processes cannot be observed directly in situ. In this study, we use temperature monitoring to detect and identify the hydrates crystallization during cooling/heating cycles a sodium sulfate solution and limestone samples saturated with the same solution. In parallel, other experimental approaches consist to measure the electrical and elastic responses of the crystallization/dissolution processes occurring in the porous media. These methods enable to characterize the different phases occurring during temperature cycle and can be used in further experimental studies about ageing test in order to estimate the role of the different sodium sulfate hydrates involved in the salt weathering of rocks.
23

Cold chain management in the food industry of Sweden : Enhanced utilization of temperature monitoring solutions

Angelova, Kristina, Petrachkova, Irina January 2015 (has links)
No description available.
24

Thermométries ultrasonore et infrarouge pour le contrôle de la protection myocardique / Ultrasonic and infrared thermometries for the control of myocardial protection

Engrand, Céline H. 30 November 2016 (has links)
Le succès de la chirurgie cardiaque dépend essentiellement de la préservation des tissus durant l'opération. Afin d'optimiser cette dernière, une protection myocardique est appliquée à travers la perfusion d'une cardioplégie hypothermique lui permettant de tolérer l'ischémie provoquée par l'absence de vascularisation. Malgré ces progrès techniques et les connaissances accumulées, la chirurgie cardiaque reste une chirurgie à risque dont les complications sont parfois de nature inconnue. Il n'existe pourtant pas de suivi opérationnel de la protection myocardique et les seules indications disponibles pour le chirurgien sont l'arrêt contractile du cœur en début de cardioplégie ou l'apparition de fibrillations cardiaques dénonçant une inefficacité à long terme de la cardioplégie. Parmi les paramètres de mesure pouvant contribuer à la surveillance du myocarde sous cardioplégie, le suivi du changement de température induit par celle-ci pourrait devenir un indicateur pertinent. L'objectif de ce travail de thèse est donc de mettre en place un dispositif de suivi thermique du cœur permettant d'évaluer concrètement la diffusion et l'efficacité de perfusion cardioplégique durant la chirurgie cardiovasculaire.Parmi les méthodes de suivi thermique non invasives implantables en salle d'opération, la thermométrie par ultrasons (TUS) et la thermographie par infrarouges (TIR) ont retenu notre attention. Dans un premier temps, une méthode directe de thermométrie par ultrasons basée sur le principe "d'écho tracking" est expérimentée via un capteur ultrasonore $2,25 MHz mono-élément sur une gamme de température de 10 à 30°C. Cependant la caractérisation du muscle cardiaque par ultrasons et les expérimentations menées en laboratoire ont mis en avant la complexité du milieu nécessitant une calibration préalable, difficile à mettre en place en conditions opératoires. La technique présente tout de même une précision de mesure satisfaisante pour une variation de température inférieure à 10°C. Un modèle d'ajustement est alors proposé afin d'identifier la tendance de réchauffement interne du cœur à partir de la température de surface mesurable via une caméra thermique à infrarouge et par l'estimation volumique du milieu par ultrasons. Le modèle est validé dans un premier temps par simulation par éléments finis et dans un second temps durant des expérimentations sur fantômes et cœur in-vitro.Au final, le dispositif multi-physique TIR et TUS est expérimenté sur modèle in-vivo lors d'opérations, durant lesquelles des sessions de refroidissement par cardioplégie hypothermique sont effectuées. L'étude se conclut sur des premiers résultats de suivi thermique satisfaisants où les températures surfaciques acquises par TIR et l'estimation de l'épaisseur des parois ventriculaires par ultrasons permettent d'obtenir efficacement la tendance de réchauffement du myocarde. Le dispositif multi-physique a également démontré la possibilité d'appliquer une calibration directe de la thermométrie ultrasonore. Cette étude de faisabilité a démontré la possibilité d'un monitoring thermique du cœur de manière non invasive et applicable en temps réel. Ce dispositif pourrait être, après adaptation spécifique, implémenté durant les interventions cardio-vasculaire et fournir un indicateur précieux aux chirurgiens quant à l'efficacité de la protection myocardique. / The success of cardiac surgery essentially depends on tissue preservation. To optimize this latter, a myocardial protection is applied thanks to a hypothermic cardioplegia that confers a marked protective effect to the heart under ischemia. Despite these technical developments, cardiac surgery still presents risks and complications are sometimes of an unknown nature. However, no operational real-time monitoring of myocardial tissue exists. Among the metrics that could be analyzed, the temperature change measurement may be a relevant indicator. The objective of the present thesis is therefore to establish a thermal monitoring system of the heart in a way to evaluate the quality of the cardioplegia perfusion during cardiovascular surgery.Among the non-invasive thermal monitoring methods implantable in the operating room, the ultrasonic thermometry and infrared thermography caught our attention. In the first stages of the study, a direct method of ultrasonic thermometry based on the echo tracking is performed on in-vitro samples with 2.25 MHz ultrasonic sensor in a temperature range between 10 to 30°C. The ultrasonic characterization of the heart muscle and the laboratory experiments brought to the forth an environmental complexity requiring prior calibration that may be difficult to implement in operational conditions. However, the technique has a satisfactory measurement accuracy for temperature variations of less than 10°C.An adjustment model is then proposed to identify the in-depth warming trend of the heart thanks to the surface temperature measurement performed by thermal infrared camera and the medium thickness estimated by ultrasound. The model is validated by finite element simulations and experiments realized on ghosts and in-vitro heart samples.Finally, the device is experimented on in-vivo animal models while hypothermic cardioplegia were conducted. Conclusive results were obtained on the heart thermal monitoring. In particular, the surface temperatures acquired by infrared thermography and the thickness estimation of the ventricular walls by ultrasound allowed an estimation of the myocardial-warming trend.This feasibility study has demonstrated the possibility of heart thermal monitoring, noninvasively and appropriate in real time. After specific adaptation, this device could be implemented during cardiovascular interventions and provide a valuable indicator for the surgeons about the efficacy of myocardial protection.
25

Ring Oscillator Based Temperature Sensor

Walvekar, Trupti 07 1900 (has links) (PDF)
The temperature sensor design discussed in this thesis, is meant mainly to monitor temperature at power outlets. Current variations in power cords have a direct impact on the surrounding temperature. Sensing these variations ,enables us to take necessary measures to prevent any hazards due to temperature rise. Thus, for this application we require a sensor with a moderate temperature error (_10C) over a sensing range of -200C to 1500C. Low power consumption and simple digitizing scheme alleviate measurement errors due to self heating effects of the sensor. A current starved inverter based ring oscillator was chosen for the sensor design in 130nm technology. The inverter delay variation with temperature is used for sensing. Linearity and process invariancy of these characteristics are fundamental to the sensor design. We observed through simulations, and confirmed by mathematical analysis, that the sensing characteristics are governed by bias current dependence on temperature. Control voltage for the bias circuitry of the oscillator determines current through the inverter stages. Hence, for linear sensing characteristics, a control voltage(Vc) just above the maximum threshold voltage of bias transistor is used. This enables generation of PTAT saturation current for current starved inverters, due to dominance of threshold voltage decrease with temperature over mobility decrease. I.Another limitation, process dependency of the sensing characteristics, was overcome through the proposed calibration based compensation technique. A changing Vc proportional to threshold voltage variation with process, process independent bias current and current temperature characteristics were obtained. This compensated for the process variation effects on frequency. Thus, a variable Vc was generated using a reference with low temperature sensitivity of 17.6_V=0C, and resistive divider combinations for various processes. Incorporating this compensation technique we achieved good linearity in sensor characteristics and a maximum temperature error of± 1.60C over the sensing range. The sensor consumes a low power of 0.29mW and also occupies minimal area.
26

BIOMEDICAL APPLICATION OF THERMOCHROMIC LIQUID CRYSTALS AND LEUCO DYES FOR TEMPERATURE MONITORING IN THE EXTREMITIES

Rao, Nilin M., Ph.D. 14 December 2016 (has links)
No description available.
27

Θεωρητική ανάλυση και πειραματική μελέτη ενός πρότυπου μικροκυματικού συστήματος για θεραπευτικές εφαρμογές υπερθερμίας

Γουζούασης, Ιωάννης 17 September 2008 (has links)
Η υπερθερμία αποτελεί μια επικουρική μέθοδο θεραπείας του καρκίνου και η βιοϊατρική έρευνα τις τελευταίες δεκαετίες, με σκοπό την εκμετάλλευση και την ανάδειξη των ιδιοτήτων της μεθόδου, στοχεύει στην εφαρμογή της στην κλινική πράξη. Μία προσπάθεια με παρόμοιο σκοπό γίνεται τα τελευταία χρόνια στο Εργαστήριο Μικροκυμάτων και Οπτικών Ινών (ΕΜΟΙ) της σχολής Ηλεκτρολόγων Μηχανικών και Μηχανικών Υπολογιστών (ΗΜΜΥ) του Εθνικού Μετσόβιου Πολυτεχνείου, όπου έχει σχεδιαστεί και κατασκευαστεί ένα σύστημα υπερθερμίας. Το προτεινόμενο σύστημα ενσωματώθηκε σε ένα τρισδιάστατο σύστημα παθητικής μικροκυματικής ραδιομετρικής απεικόνισης (ΜiRaIS) για διαγνωστικές εφαρμογές εγκεφάλου, το οποίο μελετήθηκε και κατασκευάστηκε στα πλαίσια διδακτορικής διατριβής στο ίδιο εργαστήριο της σχολής ΗΜΜΥ. Στην παρούσα διπλωματική εργασία γίνεται η θεωρητική και πειραματική μελέτη του προτεινόμενου συστήματος της υπερθερμίας. Η αρχή λειτουργίας του είναι όμοια με αυτή του MiRaIS και βασίζεται στη χρήση μια ελλειψοειδούς αγώγιμης κοιλότητας για εστίαση της ακτινοβολίας επιλεκτικά στους ιστούς που χρήζουν θεραπείας. Ο ανακλαστήρας για εστίαση, που κατασκευάστηκε και χρησιμοποιήθηκε στην πειραματική διαδικασία, βελτιώνει την εργονομία του συστήματος, διατηρώντας παράλληλα της ιδιότητες εστίασης του πρωτότυπου ελλειψοειδούς. Στα πλαίσια της παρούσας διπλωματικής εργασίας πραγματοποιήθηκε θεωρητική μελέτη και μοντελοποίηση της διάταξης με σκοπό τη βελτίωση των ιδιοτήτων εστίασής της, καθώς και πειραματικές μετρήσεις του συνολικού συστήματος υπερθερμίας-μικροκυματικής ραδιομετρίας. Στη θεωρητική μελέτη, με χρήση του λογισμικού xFDTD που βασίζεται στη μέθοδο των πεπερασμένων διαφορών στο πεδίο του χρόνου, ερευνώνται δυο μέθοδοι για τη βελτίωση των ιδιοτήτων εστίασης του συστήματος (βάθος διείσδυσης της ακτινοβολίας, χωρική διακριτική ικανότητα) με τη χρήση διηλεκτρικών υλικών. Τα υλικά αυτά τοποθετούνται στο εσωτερικό του ελλειψοειδούς καθώς και γύρω από το μοντέλο κεφαλιού ως στρώματα προσαρμογής για την επίτευξη βηματικής αλλαγής της διηλεκτρικής σταθεράς στη διεπιφάνεια αέρα-μοντέλο ανθρώπινου κεφαλιού. Στην πρώτη προσέγγιση, το εσωτερικό του ελλειψοειδούς ανακλαστήρα γεμίζει με διηλεκτρικό υλικό χαμηλών απωλειών, με τα αποτελέσματα να δείχνουν σημαντική βελτίωση της χωρικής διακριτικής ικανότητας του συστήματος. Στη δεύτερη προσέγγιση του προβλήματος, χρησιμοποιείται ένα ημισφαίριο από διηλεκτρικό γύρω από το μοντέλο κεφαλιού, με τα αποτελέσματα να δείχνουν την αντίστοιχη βελτίωση της χωρικής διακριτικής ικανότητας και παράλληλα σημαντική μείωση των ανεπιθύμητων περιοχών εστίασης της ενέργειας. Η πειραματική διάταξη τοποθετήθηκε σε ανηχοϊκό θάλαμο, όπου και πραγματοποιήθηκαν όλες οι μετρήσεις. Παράλληλα με τα πειράματα υπερθερμίας, μελετήθηκε η δυνατότητα εφαρμογής της μεθόδου της μικροκυματικής ραδιομετρίας με τη γεωμετρία του προτεινόμενου συστήματος. Η μέθοδος της μικροκυματικής ραδιομετρίας θα μπορούσε να παρέχει τον έλεγχο της θερμοκρασίας της ακτινοβολούμενης περιοχής κατά τη διάρκεια των συνεδριών της υπερθερμίας. Στις πειραματικές διαδικασίες που ακολουθήθηκαν, χρησιμοποιήθηκαν ομοιώματα νερού, τα οποία στη φάση της υπερθερμίας υπέδειξαν τις περιοχές εστίασης της ενέργειας για τη συχνότητα ακτινοβολίας, ενώ στη φάση της μικροκυματικής ραδιομετρίας βοήθησαν στη μελέτη της θερμοκρασιακής διακριτικής ικανότητας του συστήματος. Επίσης, διενεργήθηκαν μετρήσεις με στρώματα προσαρμογής από διηλεκτρικά υλικά, τα οποία τοποθετούνταν γύρω από το αντικείμενο ενδιαφέροντος, για την πληρέστερη κατανόηση της επίδρασης των υλικών αυτών στις ιδιότητες εστίασης του συστήματος και για την επιβεβαίωση των αντίστοιχων θεωρητικών αποτελεσμάτων. / The application of hyperthermia process has been widely used in clinical research and efforts are being made for its implementation in clinical practice, as many researchers have used this method as an adjunct treatment procedure for cancer. During the past two decades, a great deal of research has been carried out, with the aim of developing effective techniques for hyperthermia treatment, primarily using RF, microwave, and ultrasound energy. A similar effort is carried out in the Laboratory of Microwaves and Fiber Optics (MFOL), School of Electrical and Computer Engineering, National Technical University of Athens (NTUA), where a proposed hyperthermia system has been designed and constructed. A system for deep brain hyperthermia treatment, designed to also provide passive measurements of temperature and/or conductivity variations inside the human body, is presented in this paper. The proposed system comprises both therapeutic and diagnostic modules, operating in a totally contactless way, based on the use of an ellipsoidal beamformer to achieve focusing on the areas under treatment and monitoring. The radiometry monitoring module, the Three Dimensional Passive Microwave Radiometry Imaging System (MiRaIS), has been studied, designed and constructed in the framework of a PhD thesis in the same laboratory of MFOL. In the present thesis, the proposed system is theoretically and experimentally studied. The operation principal is based on the use of an ellipsoidal conductive wall cavity for focusing the emitted radiation on the tissues that should accept treatment. The ellipsoidal cavity, which was constructed and used in the experimentation procedure, is newly developed and improves the system’s ergonomy retaining at the same time the focusing properties of the prototype system. In the framework of the present study, theoretical modelling and experimentation of the proposed system was carried out in order to examine and improve its focusing attributes. In the theoretical study, two methods for the improvement of the system’s focusing properties (e.g. penetration depth of the electromagnetic field, spatial sensitivity) using dielectric materials are tested with the use of a commercially available software tool, xFDTD (x-Finite Difference Time Domain). The materials are placed inside the ellipsoidal or used as matching layers around the head model for the achievement of a stepped change of the refraction index on the air-human head model interface. In the first approach, the ellipsoidal volume is filled with a low loss dielectric material in order to improve the system’s spatial sensitivity. In the second approach, a hemi-sphere also filled with a dielectric material is placed around the human head model and the results revealed the improvement of the system’s spatial sensitivity and the reduction of the undesirable auxiliary energy-absorbing areas. The experiments were performed inside an anechoic chamber providing maximum accuracy by avoiding any external interference. Along with the hyperthermia experiments, the implementation of the microwave radiometry process was also tested with the proposed system. Microwave radiometry could provide the temperature monitoring of the radiated area during the hyperthermia sessions. In the experimental procedures water phantoms were used, which during hyperthermia indicated the energy-absorbing areas at the irradiation frequency, and during microwave radiometry revealed the system’s temperature sensitivity. Also, measurements were conducted using dielectric matching layers, placed around the medium of interest, in order to fully understand the effect of those materials on the system’s focusing properties as well as to confirm the respective theoretical results. Taking into consideration the present study and the advantage of the non invasive character of the proposed brain hyperthermia system, it is concluded that further research is required in order to explore its potentials at becoming a part of the standard treatment protocol of brain malignancy in the future.
28

Ανάπτυξη μη επεμβατικών συστημάτων υπερθερμίας για θεραπευτικές εφαρμογές εγκεφάλου

Γουζούασης, Ιωάννης 20 October 2010 (has links)
Η υπερθερμία αποτελεί μια επικουρική μέθοδο θεραπείας του καρκίνου και η βιοϊατρική έρευνα τις τελευταίες δεκαετίες, με σκοπό την εκμετάλλευση και την ανάδειξη των ιδιοτήτων της μεθόδου, στοχεύει στην εφαρμογή της στην κλινική πράξη. Μια προσπάθεια με παρόμοιο σκοπό γίνεται τα τελευταία χρόνια στο Εργαστήριο Μικροκυμάτων και Οπτικών Ινών (ΕΜΟΙ) της σχολής Ηλεκτρολόγων Μηχανικών και Μηχανικών Υπολογιστών (ΗΜΜΥ) του Εθνικού Μετσόβιου Πολυτεχνείου, όπου έχει σχεδιαστεί και κατασκευαστεί ένα μικροκυματικό σύστημα υπερθερμίας. Το προτεινόμενο σύστημα ενσωματώθηκε σε ένα τρισδιάστατο σύστημα παθητικής μικροκυματικής ραδιομετρικής απεικόνισης (ΜiRaIS), το οποίο παρέχει τη δυνατότητα παρακολούθησης των μεταβολών της θερμοκρασίας και της αγωγιμότητας της υπό εξέταση περιοχής σε πραγματικό χρόνο και μελετήθηκε και κατασκευάστηκε στα πλαίσια παλαιότερης διδακτορικής διατριβής στο ίδιο εργαστήριο της σχολής ΗΜΜΥ. Στην παρούσα διδακτορική διατριβή γίνεται η θεωρητική και πειραματική μελέτη του προτεινόμενου συστήματος υπερθερμίας. Η αρχή λειτουργίας του συστήματος είναι όμοια με εκείνη του MiRaIS και βασίζεται στη χρήση μιας ελλειψοειδούς αγώγιμης κοιλότητας για εστίαση της ακτινοβολίας επιλεκτικά στους ιστούς που χρήζουν θεραπείας. Ο ανακλαστήρας για εστίαση που κατασκευάστηκε και χρησιμοποιήθηκε στην πειραματική διαδικασία, βελτιώνει την εργονομία του συστήματος, διατηρώντας παράλληλα της ιδιότητες εστίασης του πρωτότυπου ελλειψοειδούς. Στα πλαίσια της παρούσας διατριβής πραγματοποιήθηκε αρχικά η θεωρητική μελέτη και μοντελοποίηση της διάταξης με σκοπό την εξακρίβωση των ιδιοτήτων εστίασης του συστήματος και στη συνέχεια επιχειρήθηκε η βελτίωση των ιδιοτήτων αυτών με χρήση διατάξεων διηελκτρικών υλικών, καθώς και πειραματικές μετρήσεις του συνολικού συστήματος υπερθερμίας-μικροκυματικής ραδιομετρίας. Η θεωρητική ηλεκτρομαγνητική μελέτη του συστήματος έγινε με τη χρήση ενός εμπορικά διαθέσιμου υπολογιστικού πακέτου προσομοίωσης (XFdtd, Remcom Inc.), το οποίο χρησιμοποιεί τη μέθοδο των πεπερασμένων διαφορών στο πεδίο του χρόνου για την επίλυση ηλεκτρομαγνητικών προβλημάτων. Ερευνώνται τρεις διατάξεις διηλεκτρικών υλικών με σκοπό τη βελτίωση των ιδιοτήτων εστίασης του συστήματος, οι οποίες επικεντρώνονται στη μελέτη του βάθους διείσδυσης της ακτινοβολίας και της χωρικής διακριτικής ικανότητας. Τα υλικά τοποθετούνται είτε στο εσωτερικό του ελλειψοειδούς είτε γύρω από το μοντέλο κεφαλιού ως στρώματα προσαρμογής, με σκοπό την επίτευξη βηματικής αλλαγής της διηλεκτρικής σταθεράς στη διεπιφάνεια αέρα-μοντέλο ανθρώπινου κεφαλιού. Τα αποτελέσματα καταδεικνύουν τα πλεονεκτήματα από τη χρήση των διηλεκτρικών υλικών, καθώς παρουσιάζεται βελτίωση και στις δυο παραμέτρους των ιδιοτήτων εστίασης, ανάλογα με τη διάταξη που χρησιμοποιείται, τη θέση του μοντέλου κεφαλιού στο εσωτερικό του συστήματος και τη συχνότητα λειτουργίας. Για τη διενέργεια των πειραμάτων, η πειραματική διάταξη τοποθετήθηκε σε ανηχοϊκό θάλαμο, ο οποίος εξασφαλίζει την απομόνωσή της από τον περιβάλλοντα χώρο. Στις πειραματικές διαδικασίες που ακολουθήθηκαν, χρησιμοποιήθηκαν ομοιώματα, τα οποία στη φάση της υπερθερμίας υπέδειξαν τις περιοχές εστίασης της ενέργειας για την εκάστοτε συχνότητα ακτινοβολίας, ενώ στη φάση της μικροκυματικής ραδιομετρίας βοήθησαν στη μελέτη της θερμοκρασιακής διακριτικής ικανότητας του συστήματος. Η μέθοδος της μικροκυματικής ραδιομετρίας χρησιμοποιήθηκε για την παρακολούθηση των μεταβολών της θερμοκρασίας της ακτινοβολούμενης περιοχής κατά τη διάρκεια των συνεδριών της υπερθερμίας. Επίσης, κατά τη διάρκεια των πειραμάτων πραγματοποιήθηκαν μετρήσεις με στρώματα προσαρμογής από διηλεκτρικά υλικά, τα οποία τοποθετήθηκαν γύρω από το αντικείμενο ενδιαφέροντος και βοήθησαν στην πληρέστερη κατανόηση της επίδρασης της παρουσίας τους στις ιδιότητες εστίασης του συστήματος και στην επιβεβαίωση των αντίστοιχων θεωρητικών αποτελεσμάτων. / The application of hyperthermia process has been widely used in clinical research and efforts are being made for its implementation in clinical practice, as many researchers have used this method as an adjunct treatment procedure for cancer. During the past two decades, a great deal of research has been carried out, with the aim of developing effective techniques for hyperthermia treatment, primarily using RF, microwave and ultrasound energy. A similar effort is carried out in the Laboratory of Microwaves and Fiber Optics (MFOL), School of Electrical and Computer Engineering, National Technical University of Athens (NTUA), where a proposed hyperthermia system has been designed and constructed. A system for deep brain hyperthermia treatment, designed to also provide passive measurements of temperature and/or conductivity variations inside the human body, is presented in the present PhD thesis. The proposed system comprises both therapeutic and diagnostic modules, operating in a totally contactless way, based on the use of an ellipsoidal beamformer to achieve focusing on the areas under treatment and monitoring. The radiometry monitoring module, the Three Dimensional Passive Microwave Radiometry Imaging System (MiRaIS), has been studied, designed and constructed in the framework of a previous PhD thesis in the same laboratory of MFOL. In the present thesis, the proposed system is theoretically and experimentally studied. The operation principal is based on the use of an ellipsoidal conductive wall cavity for focusing the emitted radiation on the tissues that should accept treatment. The ellipsoidal cavity, which was constructed and used in the experimentation procedure, is newly developed and improves the system’s ergonomics retaining at the same time the focusing properties of the prototype system. In the framework of the present work, theoretical modeling and experimentation of the proposed system is carried out in order to examine and improve its focusing attributes. In the theoretical study, three setups are investigated for the improvement of the system’s focusing properties (e.g. penetration depth of the electromagnetic field, spatial sensitivity) using dielectric materials. The research is carried out with the use of a commercially available software tool, XFdtd (Remcom Inc.). The materials are placed inside the ellipsoidal or used as matching layers around the head model for the achievement of a stepped change of the refraction index on the air-human head model interface. The results revealed the possible advantages of using matching dielectric materials, as improvement on the focusing properties of the system is clearly observed, depending on the setup used, the position of the head model inside the system and the operating frequency. The experiments were performed inside an anechoic chamber providing maximum accuracy by avoiding all possible EMC/EMI issues. Along with the hyperthermia experiments, the implementation of the microwave radiometry process was also tested with the proposed system. Microwave radiometry could provide the temperature monitoring of the radiated area during the hyperthermia sessions. In the experimental procedures water phantoms were used, which during hyperthermia indicated the energy absorbing areas at the irradiation frequency, while during microwave radiometry revealed the system’s temperature sensitivity. Also, measurements were conducted using dielectric matching layers, placed around the medium of interest, in order to fully understand the effect of those materials on the system’s focusing properties as well as to confirm the respective theoretical results. Taking into consideration the present study and the advantage of the non invasive character of the proposed brain hyperthermia system, it is concluded that further research is required in order to explore its potentials at becoming a part of the standard treatment protocol of brain malignancy in the future.
29

Hemautomation

Olofsson, Gustav, Kareliusson, Johan, Sandell, Christofer January 2013 (has links)
Det problem som denna uppsats hade för avsikt att besvara var varför hemautomation inte används i fler hem. Genom resultaten från en enkät som distribuerades kunde slutsatsen att kostnaden för de befintliga lösningar som finns på marknaden idag inte låg i den prisklass våra respondenter ansåg rimlig. Författarna utvecklade då problemet och ställde sig frågan om en hemautomationslösning verkligen måste ha en så hög kostnad som de befintliga lösningarna har idag. För att belysa detta problem implementerades en egen kostnadseffektiv lösning där respondenternas mest önskvärda funktioner togs i beaktande och en testmiljö implementerades utefter dessa. Resultatet blev en hemautomationslösning med stor potential och med en betydligt lägre kostnad än dagens befintliga lösningar. / The problem this study intended to answer was why home automation is not used in more homes. The results of a survey that was distributed could conclude that the cost of existing solutions available on the market today is not within the price range our respondents considered reasonable. The authors then evolved the problem and asked themselves whether home automation really need such a high cost as the existing solutions today. To illustrate this problem, the authors implemented a cost-effective solution where respondents' most popular features were in regard. The result was a home automation solution with great potential and with a significantly lower cost than today's existing solutions.
30

Implementation of Machine Learning and Internal Temperature Sensors in Nail Penetration Testing of Lithium-ion Batteries

Casey M Jones (9607445) 13 June 2023 (has links)
<p>This work focuses on the collection and analysis of Lithium-ion battery operational and temperature data during nail penetration testing through two different experimental approaches. Raman spectroscopy, machine learning, and internal temperature sensors are used to collect and analyze data to further investigate the effects on cell operation during and after nail penetrations, and the feasibility of using this data to predict future performance.</p> <p><br></p> <p>The first section of this work analyzes the effects on continued operation of a small Lithium-ion prismatic cell after nail penetration. Raman spectroscopy is used to examine the effects on the anode and cathode materials of cells that are cycled for different amounts of time after a nail puncture. Incremental capacity analysis is then used to corroborate the findings from the Raman analysis. The study finds that the operational capacity and lifetime of cells is greatly reduced due to the accelerated degradation caused by loss of material, uneven current distribution, and exposure to atmosphere. This leads into the study of using the magnitude and corresponding voltage of incremental capacity peaks after nail puncture to forecast the operation of damaged cells. A Gaussian process regression is used to predict discharge capacity of different cells that experience the same type of nail puncture. The results from this study show that the method is capable of making accurate predictions of cell discharge capacity even with the higher rate of variance in operation after nail puncture, showing the method of prediction has the potential to be implemented in devices such as battery management systems.</p> <p><br></p> <p>The second section of this work proposes a method of inserting temperature sensors into commercially-available cylindrical cells to directly obtain internal temperature readings. Characterization tests are used to determine the effect on the operability of the modified cells after the sensors are inserted, and lifetime cycle testing is implemented to determine the long-term effects on cell performance. The results show the sensor insertion causes a small reduction in operational performance, and lifetime cycle testing shows the cells can operate near their optimal output for approximately 100-150 cycles. Modified cells are then used to monitor internal temperatures during nail penetration tests and how the amount of aging affects the temperature response. The results show that more aging in a cell causes higher temperatures during nail puncture, as well as a larger difference between internal and external temperatures, due mostly to the larger contribution of Joule heating caused by increased internal resistance.</p>

Page generated in 0.089 seconds