• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 50
  • 16
  • 4
  • Tagged with
  • 65
  • 65
  • 24
  • 23
  • 22
  • 22
  • 21
  • 19
  • 15
  • 12
  • 11
  • 11
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Production et caractérisation d'agrégats moléculaires protonés contenant un nombre donné de molécules d'eau auprès de dispositif DIAM

Bruny, Guillaume 03 December 2010 (has links) (PDF)
La compréhension de l'irradiation à l'échelle du nanomètre dans les systèmes biomoléculaires nécessite l'observation de caractéristiques nouvelles auxquelles les développements techniques actuels nous permettent d'accéder. Ce travail se situe au coeur de la construction du nouveau dispositif DIAM Dispositif d'Irradiation d'Agrégats de Molécules biologiques développé à l'Institut de Physique Nucléaire de Lyon. Le développement d'une source d'agrégats associée à un spectromètre de masse à double focalisation a permis l'obtention des premiers faisceaux d'agrégats moléculaires protonés sélectionnés en masse. De plus, un système de détection innovant a été développé et validé dans des expériences de dissociations d'agrégats d'eau protonés par collision sur un gaz. Les résultats obtenus contribuent à la connaissance de la stabilité et de la structure des petits agrégats d'eau protonés et des agrégats mixtes d'eau et de pyridine protonés
12

Mesure de la cinétique de formation du dimère de l'eau à basses températures / Kinetics measurements of water dimer formation at low temperatures

Roussel, Vivien 13 December 2013 (has links)
L'eau est une molécule omniprésente dans notre environnement, mais également dans notre atmosphère. La compréhension des phénomènes physico-chimiques tels que la solvatation, la formation d'agrégats et d'aérosols dans l'atmosphère requièrent une bonne connaissance de la nucléation homogène de l'eau. Dans ce cadre, la dimérisation constitue la toute première étape de ce processus où deux molécules de structure similaire sont fortement rapprochées par des interactions intermoléculaires, sans former de liaisons chimiques, conduisant ensuite à la formation d'agrégats de plus grandes tailles et à la condensation. Le dimère de l'eau est une cible d'étude des chimistes et des physiciens depuis le début du XXe siècle. En effet, certains physiciens pensent qu'une partie de l'absorption du rayonnement solaire terrestre est dû au dimère tandis que des chimistes débattent de son implication dans le mécanisme de formation de l'acide sulfurique responsable des pluies acides. On retrouve également le dimère de l'eau au sein des comètes ainsi que de l'eau dans de nombreux environnements astrophysiques. Pour répondre à ces différentes problématiques, il est nécessaire de quantifier la présence du dimère de l'eau dans notre atmosphère. Ce mémoire présente l'étude expérimentale de la cinétique de formation du dimère de l'eau sur une gamme de températures s'étendant de 23 à 74 K. Cette étude a été réalisé en utilisant un dispositif dédié à l'étude des espèce condensables. Elle a associé plusieurs techniques dont les écoulements CRESU (Cinétique de Réaction en Ecoulement Supersonique) et un spectromètre de masse à temps de vol. Un canon à électrons a par ailleurs été ajouté au dispositif afin de permettre l'ionisation des agrégats que nous formons. Les résultats des études de cinétique à 23K, 36K, 49K, 63K et 74K ont été reportés et la dépendance en pression du coefficients de vitesse de la dimérisation de l'eau a été examinée à 23K. / Kinetics measurements of water dimer formation at low temperatures
13

Conception d'impulsions radiofréquence en transmission parallèle pour la sélection homogène de tranches et leur application à l'angiographie en temps de vol du cerveau humain en IRM à 7 Tesla / Radiofrequency pulse design with parallel transmission for uniform large slab selections and their application to Time-Of-Flight MR angiography of the human brain at 7T

Saïb, Gaël 11 June 2018 (has links)
L’IRM à ultra haut champ (UHC) donne accès à une résolution spatiale submillimétrique rendant possible la visualisation de structures plus fines qu’en IRM classique. Depuis quelques années, son potentiel s’est développé dans des laboratoires tels que NeuroSpin, au sein du CEA, qui a l’ambition d’étudier l’anatomie et le fonctionnement du cerveau à une échelle mésoscopique. Toutefois, pour des champs magnétiques supérieurs à 3T, le champ radiofréquence (RF) permettant d’exciter les protons de l’eau a une longueur d’onde inférieure à la dimension de la tête humaine, provoquant des phénomènes d’interférences destructives dans le cerveau. Ceux-ci s’accentuent avec l’augmentation du champ statique, engendrant sur les images des inhomogénéités de signal ou de contraste, qui empêchent d’exploiter tout le potentiel de l’imagerie UHC. Pour améliorer la pertinence des diagnostics cliniques, à défaut de pouvoir homogénéiser le champ RF dans tout le cerveau, il est essentiel de réussir à uniformiser l’excitation des spins. Dans ce but, un système de transmission parallèle (pTx) à 8 canaux a été intégré à l’imageur 7T du laboratoire. Il permet d’émettre sur chaque canal des formes d’impulsions RF différentes, à optimiser pour faire interférer le champ RF produit dans le cerveau de manière plus contrôlée que dans le mode classique à un seul canal d’émission. Ces travaux de thèse consistent à mettre au point des impulsions RF utilisant la pTx pour sélectionner des tranches d’excitation uniforme, et à les appliquer à l’angiographie du cerveau humain à 7T. A UHC, la méthode la plus courante pour homogénéiser l’angle de bascule de l’aimantation dans une coupe consiste à générer consécutivement plusieurs impulsions sélectives optimisées, appelées « spokes », à différentes positions du plan transverse à la coupe dans l’espace de Fourier de transmission. Si elle convient pour uniformiser l’excitation dans le plan de coupe, cette méthode est moins performante pour la sélection de larges tranches car les inhomogénéités de champ RF ne sont alors pas prises en compte dans l’épaisseur de tranche. Ainsi, dans un premier temps, deux méthodes originales de conception d’impulsions RF sélectives sont introduites et explorées pour uniformiser l’excitation de larges tranches : celle des « kT-spokes » qui optimise le placement des spokes dans les 3 dimensions de l’espace de Fourier de transmission, et celle des « spokes 3D » qui génère des impulsions RF optimisées point par point dans le temps. Ces techniques ont été validées avec succès sur des fantômes à 7T et ont permis de surpasser l’état de l’art en termes d’homogénéisation de l’angle de bascule pour la sélection de larges tranches. Dans un deuxième temps, ces méthodes ont été appliquées à la séquence d’angiographie 3D en temps de vol afin d’améliorer la visualisation du réseau artériel dans le cerveau humain à 7T. Cependant, lorsque les tranches sélectionnées sont larges, cette séquence est aussi sensible aux effets de saturation du sang qui empêchent d’apprécier la totalité du réseau artériel avec les profils de tranche d’angles de bascule plats habituels. Pour corriger ce phénomène, les impulsions RF à rampes sont proposées dans l’état de l’art, générant des profils d’angle de bascule qui augmentent avec l’épaisseur de la tranche. Les méthodes de conception d’impulsions RF développées ici ont ainsi été adaptées pour générer ce type de profils et permettre de compenser la saturation du sang avec succès dans les acquisitions à 7T. Ces travaux de thèse ont permis d’ouvrir la voie à une nouvelle application à NeuroSpin puisque l’angiographie n’y avait pas encore été explorée malgré le fort potentiel des UHC pour cette modalité. En outre, les méthodes développées au cours de ces travaux permettent l’excitation simultanée de tranches homogènes, constituant ainsi une perspective prometteuse pour accélérer les acquisitions et repousser les limites de résolution spatiale de l’angiographie en temps de vol à 7T. / Ultra-high field (UHF) MRI allows submillimetric spatial resolution in order to depict finer structures compared to conventional MRI. In recent years, the UHF potential has been explored in laboratories such as NeuroSpin, at Commissariat à l’Énergie Atomique et aux Énergies Alternatives (CEA), to study brain anatomy and function at a mesoscopic scale. However, for high magnetic field strengths (> 3 Tesla), the radiofrequency (RF) field required to excite the water protons has a wavelength shorter than the size of the human head, causing destructive interferences in the brain. These increase with the static field strength leading to signal or contrast inhomogeneity artefacts on brain images, hindering the UHF benefits. However, failing to homogenize the RF field produced in the brain does not preclude from homogenizing the spin excitation to improve image quality and perform better clinical diagnosis. For this purpose, NeuroSpin’s 7T scanner has been equipped with an 8-channel parallel transmission system allowing to transmit independent optimized RF shapes on each channel in order to better control RF field interferences than in conventional single transmit channel. This thesis work focuses on RF pulse design strategies using parallel transmission to select slabs uniformly and on their applications to magnetic resonance angiography (MRA) of the human brain at 7T. In the UHF context, the most common method to homogenize the magnetization flip angle in a slice consists in combining several consecutive optimized selective excitations, so-called “spokes” subpulses, in different locations of the plane transverse to the slice in transmit k-space. Even though this method succeeds in homogenizing the in-plane excitation, its performance is not optimal in large slabs because through-slab RF inhomogeneities are not taken into account. In a first step, two original selective pulse design methods are introduced and explored to homogenize large slab selections: the “kT-spoke” method which optimizes the spoke placements in the three dimensions of the transmit k-space, and the “3D spokes” which consist in optimizing the RF subpulses point by point in time. These methods have been successfully validated in phantoms at 7T and surpassed the state of the art performance in terms of flip angle homogeneity in large slab selections. In a second step, these methods are applied to 3D Time-Of-Flight (TOF) MR angiography to improve the visualization of the arterial network in the human brain at 7T. As most MRI sequences, TOF is particularly sensitive to RF field heterogeneities. Moreover, for large uniform slab excitation, blood saturation effects prevent the depiction of the arterial network before slab exit. To correct for these effects, ramp RF pulses are proposed in the state-of-the-art, generating ascending flip angle profiles through the slab. The RF pulse design methods developed hereby were adapted to generate these profiles, successfully compensating blood saturation in 7T acquisitions. This work paves the way to a new clinical application at NeuroSpin, where MR angiography had not been explored yet, despite the high benefit of UHF for this modality. In addition, the methods developed hereby were also adapted for simultaneous multi-slice excitations. This allows promising perspectives to accelerate acquisitions and push further away the limits of TOF angiography in terms of spatial resolution.
14

Design of the Cherenkov TOF whole-body PET scanner using GATE simulation / Conception du scanner TEP Tchérenkov, corps entier, temps de vol en utilisant un logiciel de simulation GATE

Alokhina, Marharyta 20 September 2018 (has links)
Dans cette thèse, nous présentons la conception et l’étude de performance d’un tomographe par émission de positrons (TEP) corps entier utilisant la radiation Cherenkov avec capacité de temps-de-vol (projet PECHE). Nos résultats et les conclusions sont basés sur la simulation GATE pour la configuration du scanner suivante: cristal de fluorure de plomb attaché à un photomultiplicateur à micro-canaux. C’est un cristal de haute densité, transparent pour les photons ultraviolet, et possède la fraction photoélectrique la plus élevé de 46%. Le photomultiplicateur choisi est un détecteur de grande taille, rapide et pixélisé avec une efficacité quantique raisonnable, de 25% à une longueur d'onde de 400 nm. Grâce à ces propriétés, il est possible d’envisager un détecteur efficace de gamma de 511 keV avec une épaisseur de cristal de 10 mm (une longueur d'interaction) et donc de minimiser la longueur et dispersion des trajectoires de photons, résultant à une résolution temporelle optimisée. Nous avons étudié les configurations différentes de détecteur élémentaire tels que le cristal avec les épaisseurs de 10 et 20 mm, le diamètre de l'anneau de détection de 80 et 90 cm, diverses options de le revêtement de cristal (noir, blanc diffus et poli) et deux interfaces optiques (collage moléculaire et assemblage conventionnel avec un gel optique). Pour une configuration optimale, nous avons choisi un scanner TEP à trois anneaux avec un diamètre de l'anneau de 80 cm, cristal de 10 mm d'épaisseur, et un blindage en plomb. Le collage moléculaire donne une meilleure photo-collection comparée à configuration avec un gel optique. Nous avons estimé le potentiel du scanner envisagé en utilisant les tests recommandés par la norme NEMA NU 2-2012. En particulier, nous avons évalué le taux de comptage de bruit équivalent (NECR), la résolution spatiale, coefficients de recouvrement de contraste de l'image et la variabilité de bruit de fond pour le fantôme de qualité d’image. La reconstruction des images est faite en utilisant l'algorithme itératif temps-de-vol implémenté dans la plate-forme de reconstruction « open source » CASToR récemment développée. Nous avons conclu qu’un scanner corps entier utilisant la lumière Cherenkov pourrait atteindre des performances comparables à celles d'un tomographe classique à scintillation grâce à son excellente résolution temps-de-vol. L'utilisation du rayonnement Cherenkov permet d'atteindre une résolution en temps-de-vol encore meilleure. Il est limité actuellement par la dispersion de temps de transit des photomultiplicateurs existants, un faible nombre de photons optiques détectés et une efficacité de collecte de photons dans un cristal limitée. Les limitations physiques identifiées dans cette étude seront abordées dans le développement du futur photodétecteur amélioré utilisant le radiateur PbWO₄, qui permet de concevoir un scanner TEP corps entier avec une excellente performance temps-de-vols. / In this thesis we present the conception and performance studies of the foreseen Cherenkov whole-body positron emission scanner with time-of-flight potential (PECHE project). Our results and conclusions are based on the GATE simulation for following scanner configurations: lead fluoride crystal coupled with micro-channel-plate photomultiplier. This crystal is characterized by high density, transparency for photons in ultraviolet region, and one of the highest photoelectric fraction of about 46%. The chosen photomultiplier is fast, pixelized detector of a large size with a reasonable quantum efficiency, of 25% for 400 nm photon wavelength. Due to these properties, it is possible to create an efficient 511-keV gamma detector with a crystal thickness of the order of 10 mm(one interaction length) and hence minimize the length and dispersion of the photon trajectories, leading to better time resolution. We considered different configurations of the elementary detectors such as crystal thicknesses of 10 and 20 mm, the detector ring diameter of 80 and 90 cm, various options of the crystal coating (black, diffuse white and polished) and two optical interfaces (molecular bonding and conventional assembling with an optical gel). As an optimal configuration we chose a three-ring pet scanner with diameter of the ring 80 cm, 10 mm-thick crystal, protected with lead shielding. Molecular bonding gives better photo-collection if compare with configuration with optical gel. We estimated the potential of the foreseen scanner following the prescription of the NEMA NU 2-2012 standard. In particular, we evaluated the noise equivalent count rate (NECR), spatial resolution, image contrast recovery coefficients versus background variability for the NEMA image quality phantom. Reconstruction of images is done using iterative TOF algorithm implemented in the recently developed open source reconstruction platform CASToR. We concluded that due to an excellent TOF resolution a crystal-based Cherenkov whole-body scanner could achieve performances comparable with a conventional, scintillation-based tomograph. The use of the Cherenkov radiation allows to achieve even much better TOF resolution, but currently it is limited by the transit time spread of the existing photomultipliers, a low number of the detected optical photons, and a limited photon collection efficiency in a crystal. Limitations identified in this study will be addressed in the future development of the improved photodetector using the PbWO₄ radiator, which allows to conceive a whole-body PET scanner with an excellent TOF performance.
15

Réalisation d'un convertisseur temps-numérique en CMOS 65 nm pour une intégration par pixel dans un module de comptage monophotonique

Roy, Nicolas January 2015 (has links)
Les applications nécessitant une grande précision temporelle sont de plus en plus nombreuses, notamment lorsqu'elles requièrent des mesures par temps de vol, c'est-à-dire de mesurer le temps de propagation de la lumière ou de particules. La télémétrie laser et certaines modalités d'imagerie médicale dont la tomographie d'émission par positrons (TEP) en sont des exemples. Ces applications requièrent l'attribution d'étampes temporelles aux photons détectés, tout en assurant une précision temporelle exceptionnelle. Le Groupe de Recherche en Appareillage Médical de Sherbrooke (GRAMS) développe des scanners TEP visant à intégrer des mesures par temps de vol pour améliorer le contraste des images. Pour ce faire, une partie du GRAMS (GRAMS3D) se concentre sur la réalisation de modules de comptage monophotoniques (MCMP) à grande précision temporelle pour intégrer les prochaines générations de scanners TEP. D'autres projets pourraient également se concrétiser dans les prochaines années, dont l'intégration des MCMP du GRAMS dans le Grand Collisionneur de Hadrons (Large Hadron Collider, LHC) au CERN pour des expériences en physique des hautes énergies. Pour atteindre de tels niveaux de performances, le MCMP se compose d'une matrice de photodiodes à avalanche monophotoniques intégrée en 3D avec l'électronique frontale et l'électronique de traitement de l'information. Certains MCMP n'utilisent qu'un seul convertisseur temps-numérique (CTN) pour une matrice de photodétecteurs, limitant le nombre d'étampes temporelles disponibles en plus d'obtenir un temps de propagation différent entre chacun des pixels et le CTN. Pour surpasser ces inconvénients, une autre approche consiste à intégrer un CTN à chacun des pixels. C'est dans cette perspective que le présent ouvrage se concentrera sur le CTN implanté dans chacun des pixels de 50 × 50 µm[indice supérieur 2] du MCMP développé au GRAMS. Le CTN proposé est basé sur une architecture vernier à étage unique afin d'obtenir une excellente résolution et une linéarité indépendante des variations de procédé. Sa taille de 25 × 50 µm[indice supérieur 2] et sa consommation de 163 µW en font un excellent choix pour une implantation matricielle. Le CTN, calibré en temps réel grâce à une boucle à verrouillage de phase numérique, a démontré une résolution de 14,4 ps avec une non-linéarité intégrale (INL)/non-linéarité différentielle (DNL) de 3,3/0,35 LSB et une précision temporelle inférieure à 27 ps[indice inférieur rms]. Les résultats obtenus prouvent qu'il est possible de concilier d'excellentes résolution et précision temporelles avec de très faibles dimensions et consommation.
16

Modélisation du bruit et étalonnage de la mesure de profondeur des caméras Temps-de-Vol / Noise modeling and calibration of the measuring depth of cameras Time-of-Flight

Belhedi, Amira 04 July 2013 (has links)
Avec l'apparition récente des caméras 3D, des perspectives nouvelles pour différentes applications de l'interprétation de scène se sont ouvertes. Cependant, ces caméras ont des limites qui affectent la précision de leurs mesures. En particulier pour les caméras Temps-de-Vol, deux types d'erreur peuvent être distingués : le bruit statistique de la caméra et la distorsion de la mesure de profondeur. Dans les travaux de la littérature des caméras Temps-de-Vol, le bruit est peu étudié et les modèles de distorsion de la mesure de profondeur sont généralement difficiles à mettre en œuvre et ne garantissent pas la précision requise pour certaines applications. L'objectif de cette thèse est donc d'étudier, modéliser et proposer un étalonnage précis et facile à mettre en œuvre de ces 2 types d'erreur des caméras Temps-de-Vol. Pour la modélisation du bruit comme pour la distorsion de la mesure de profondeur, deux solutions sont proposées présentant chacune une solution à un problème différent. La première vise à fournir un modèle précis alors que le second favorise la simplicité de la mise en œuvre. Ainsi, pour le bruit, alors que la majorité des modèles reposent uniquement sur l'information d'amplitude, nous proposons un premier modèle qui intègre aussi la position du pixel dans l'image. Pour encore une meilleure précision, nous proposons un modèle où l'amplitude est remplacée par la profondeur de l'objet et le temps d'intégration. S'agissant de la distorsion de la mesure de profondeur, nous proposons une première solution basée sur un modèle non-paramétrique garantissant une meilleure précision. Ensuite, pour fournir une solution plus facile à mettre en œuvre que la précédente et que celles de l'état de l'art, nous nous basons sur la connaissance à priori de la géométrie planaire de la scène observée. / 3D cameras open new possibilities in different fields such as 3D reconstruction, Augmented Reality and video-surveillance since they provide depth information at high frame-rates. However, they have limitations that affect the accuracy of their measures. In particular for TOF cameras, two types of error can be distinguished : the stochastic camera noise and the depth distortion. In state of the art of TOF cameras, the noise is not well studied and the depth distortion models are difficult to use and don't guarantee the accuracy required for some applications. The objective of this thesis is to study, to model and to propose a calibration method of these two errors of TOF cameras which is accurate and easy to set up. Both for the noise and for the depth distortion, two solutions are proposed. Each of them gives a solution for a different problem. The former aims to obtain an accurate model. The latter, promotes the simplicity of the set up. Thereby, for the noise, while the majority of the proposed models are only based on the amplitude information, we propose a first model which integrate also the pixel position in the image. For a better accuracy, we propose a second model where we replace the amplitude by the depth and the integration time. Regarding the depth distortion, we propose a first solution based on a non-parametric model which guarantee a better accuracy. Then, we use the prior knowledge of the planar geometry of the observed scene to provide a solution which is easier to use compared to the previous one and to those of the litterature.
17

Transmission and capture cross section measurements by the time-of-flight technique for validation of pile-oscillation experiments in the Minerve reactor / Mesures des sections efficaces de réaction par la technique du temps de vol pour la validation des mesures d'oscillation réalisées dans le réacteur Minerve

Salamon, Lino 28 September 2018 (has links)
Ce travail présente l'étude de faisabilité des mesures de transmission avec des échantillons MINERVE à l'installation de temps de vol GELINA. L'idée principale était de définir des procédures pour analyser les résultats des mesures de transmission réalisées avec des échantillons cylindriques ne répondant pas à la géométrie de transmission idéale. La capacité d'extraire des résultats fiables a été démontrée sur l'exemple des échantillons MINERVE enrichis en argent. De plus, des mesures de transmission et de capture avec des disques standards d'argent naturel ont été effectuées pour améliorer les paramètres de résonance pour 107Ag et 109Ag. Les principales étapes de ce travail sont la réduction des données brutes (taux de comptage) pour produire des spectres de transmission et de rendement de capture, puis l'analyse des spectres avec le code d'analyse de forme des résonances REFIT. / This work presents the feasibility study of transmission measurements with the MINERVE samples at time-of-flight facility GELINA. The main idea was to define procedures to analyse results of transmission measurements using cylindrical samples which do not fulfil the ideal transmission geometry. Capability of extracting reliable results was demonstrated on the example of MINERVE samples enriched in silver. In addition, transmission and capture measurements with standard discs of natural silver were performed to improve the resonance parameters for 107Ag and 109Ag. The main steps in this work are the data reduction of measured count rate spectra to produce final transmission and capture yield spectra and the spectra analysis with the resonance shape analysis code REFIT.
18

Characterization of T2L2 (Time Transfer by Laser Link) on the Jason 2 ocean altimetry satellite and Micrometric laser ranging

Vrancken, Patrick 23 September 2008 (has links) (PDF)
Le schéma de T2L2 (Transfert de Temps par Lien Laser), basé sur la technologie de la télémétrie laser (SLR), représente un nouveau moyen pour la synchronisation d'horloges distantes. L'expérience T2L2 fut acceptée par le CNES en 2005 d'être embarqué sur le satellite d'altimétrie des mers Jason 2.<br />La première partie de ce travail traite la caractérisation intégrale de l'instrument spatial T2L2, incluant la calibration et l'évaluation de sa performance en métrologie de temps/fréquence. Ces tests furent menée à l'aide d'un banc de test de haute complexité, développé à l'Observatoire de la Côte d'Azur.<br />Par ailleurs, le document décrit un bilan des performances du schéma intégrale T2L2, incluant l'instrument spatial ainsi que le segment sol et autres contributeurs ; par conséquent on démontre la performance finale de tout le transfert de temps: Avec une stabilité de quelques picosecondes en intégrant pendant un passage du satellite, T2L2 permettra de comparer les horloges les plus avancés, incluant les fontaines atomiques. L'exactitude absolue d'un transfert de temps fut déterminé à moins que 50 ps en configuration vue commune.<br /><br />La deuxième partie du document présent est orientée autour l'extension de la technologie de télémétrie laser et T2L2 à la mesure absolue et de très haute résolution de distances en espace.<br />Cet objectif devra être atteint en utilisant un laser de peigne de fréquences en combinant la mesure de temps de vol avec une mesure interférométrique.<br />Le document décrit un pas important vers la faisabilité de cet approche, la mesure de distances en datation à très haute cadence et en mesure de phase, ce qui devrait permettre de franchir le seuil de la longueur d'onde.
19

Transport de charge dans des matériaux hybrides composés de polymères π-conjugués et de nanocristaux de semi-conducteurs

Couderc, Elsa 01 December 2012 (has links) (PDF)
Cette thèse a pour but d'étudier le transport de charges photogénérées dans des matériaux hybrides composés de polymères π-conjugués et de nanocristaux de semi-conducteurs, conçus pour des applications en opto-électronique. La synthèse chimique permet d'obtenir des nanocristaux de CdSe à l'échelle du gramme ayant une faible polydispersité et des formes contrôlées (sphériques, branchées). Les ligands de surface des nanocristaux de CdSe sont échangés par de petites molécules (pyridine, éthanedithiol, phénylènediamine, butylamine, benzènedithiol) afin d'augmenter leur conductivité. L'échange de ligands modifie les niveaux énergétiques des nanocristaux, comme le montrent des études optiques et électrochimiques. Le poly(3-hexylthiophène) déposé sous forme de couches minces présente différents degrés de couplage intermoléculaire et de désordre énergétique selon la méthode de dépôt et le solvant utilisé. Dans les films hybrides, des mesures de diffraction de rayons X en incidence rasante montrent que la structuration cristalline de la matrice organique est modifiée par la présence des nanocristaux. Les mesures de Temps-de-Vol dans les couches hybrides montrent que les mobilités des trous et des électrons varient avec le contenu en nanocristaux, ainsi qu'avec leur forme et leurs ligands. De faibles fractions de nanocristaux provoquent une amélioration de la mobilité des trous, tandis que de plus grandes fractions la détériorent. Les mobilités électroniques sont soumises à une fraction-seuil, assimilable à un seuil de percolation. La fraction optimale de nanocristaux, du point de vue des mobilités des trous et des électrons, est de 36% en volume pour les nanocristaux sphériques avec les ligands de synthèse. Enfin, les simulations Monte-Carlo des courants transitoires photogénérés, dans un échantillon de poly(3-hexylthiophène) et dans un hybride, montrent d'une part que la distribution énergétique du poly(3-hexylthiophène) domine l'allure des courants simulés et d'autre part que les nanocristaux peuvent être assimilés à des sites difficilement accessibles du réseau cubique.
20

Application de techniques de diffusion elastique de particules alpha et d'ions lourds a l'analyse chimique des couches minces et des surfaces

Ziani, Abderrahim 29 May 1986 (has links) (PDF)
Ce travail tire partie de deux aspects de la diffusion elastique: retrodiffusion Rutherford ou non de particules alpha pour l'etude de la stoechiometre de couches minces complexes et production de noyaux de recul sous bombardement d'ions argon energetiques (16-20 MeV) pour l'analyse de surface d'elements legers comme oxygene azote et carbone. La premiere partie traite des conditions d'analyse de couches Ti$_(n-x)$Nb$_x$O$_2$ et Ti$_(l-x)$V$_x$O_$2$ dont la composition depend des parametres du depot par pulverisation cathodique H.F. de melange de poudres d'oxydes. On a determine en premier lieu les conditions d'analyse de ces couches avec la meilleure precision possible: dans les cas les plus favorables la concentration d'oxygene et le rapport des metaux sont connus a mieux de 5%. En ce qui concerne les resultats proprement dits nous montrons que pour les meilleures conditions de depot (vide residuel prepulverisation) le rapport O/(M+Ti) peut etre ajuste a 2 $\pm$ 0.1 sur toute la gamme de concentration cible. L'evolution des rapports Nb/(Nb+Ti) et V/(V+Ti) n'est pas identique a ceux des cilbes avec des ecarts dont nous tentons d'interpreter la signification. Dans la seconde partie traitant de la detection en temps de vol des noyaux de recule nous justifions le choix de nos parametres experimentaux par une etude detaillee de leur influence sur les performances analytiques. Malgre la serieuse limitation de la dispersion angulaire, la resolution en profondeur varie typiquement de 2 a 5 nm pour oxygene et carbone suivant qu'on s'adresse a une matrice de Z moyen (Si) ou eleve (Ta). L'apport d'une discrimination en energie a pour effet d'optimaliser les profondeurs analysables et d'eviter les interferences (C, N et O analysables sur 70 nm). Cette discrimination permet aussi d'abaisser les limites de detection (jusqu'a 10${13}$ at/cm$2$) par reduction du bruit de fond. Les limitations actuelles et les ameliorations possibles sont presentees a partir d'exemples d'analyse de surface.

Page generated in 0.0304 seconds