• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 385
  • 336
  • 86
  • 52
  • 37
  • 21
  • 18
  • 14
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • Tagged with
  • 1168
  • 506
  • 236
  • 225
  • 221
  • 181
  • 177
  • 157
  • 152
  • 118
  • 109
  • 101
  • 97
  • 94
  • 94
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Aspectos da deformacao do aluminio em ensaios de tracao

QUADROS, NEY F. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:31:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:40Z (GMT). No. of bitstreams: 1 02238.pdf: 7874589 bytes, checksum: 2508ea5b8a12f7656ab705c285fb99b3 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
292

Avaliação das armaduras de tração de riser flexível durante ensaios axiais de tração e fadiga

Bueno, Antonio Fernando Burkert January 2010 (has links)
O presente trabalho tem como objetivo avaliar as tensões atuantes no conjunto conector e duto flexível de camadas não aderentes durante ensaios com carregamentos axiais de tração e fadiga. Estes ensaios são utilizados para a qualificação de dutos flexíveis. Foram desenvolvidos e patenteados alguns modelos de conectores contemplando apenas a parte estrutural. Ensaios preliminares de tração e fadiga, com dois conectores diferentes e um segmento de riser de dimensões reduzidas, foram realizados visando a seleção do modelo de melhor desempenho em um pórtico. O conector de melhor desempenho foi então ensaiado em uma bancada com dimensões que atendessem ao documento da Petrobras a I-ET 3500.00.6500-291-PAZ-001 - Non standartized Prototype qualification tests of flexible pipes (2007). Tanto os ensaios do pórtico como o de bancada, foram monitorados com strain gages colados nos tendões da armadura externa de tração próximos aos conectores. O foco deste trabalho está nas armaduras de tração na interface com a resina do conector. Questões quanto ao desempenho da mesma em fadiga são de grande importância prática. Complementando a parte experimental, foram construídos modelos sólidos tridimensionais, baseados no Método dos Elementos Finitos para análise das tensões. A comparação dos resultados das diferentes metodologias validou o modelo numérico possibilitando melhor entendimento das variações de tensões nas armaduras de tração na interface com os conectores. Isso possibilitou responder a importantes questões quanto ao desempenho em fadiga bem como possíveis melhorias no projeto de conectores para dutos flexíveis. Existem trabalhos referentes à análise de tensões dos tendões nos conectores considerando o estado plano de tensões. O presente estudo dos tendões usando modelos tridimensionais, abordagem não encontrada em literatura aberta, avalia melhor a concentração de tensões nos tendões na entrada do conector. A motivação deste estudo se deve tanto à falta de informações detalhadas das tensões e deformações nos tendões na interface com o conector, como pela importância das mesmas, em componentes vitais à explotação de petróleo Offshore. / This aim of this work is to evaluate stresses which actuate on a system made up of a unbonded flexible pipe and a end fitting during static and dynamic axial loading mechanical tests. These tests are used as a means of qualification of flexible pipes. The structural design of models of end fittings were developed and patented. Preliminary static and dynamic tests with two different end fittings and a smalldimensioned riser segment were performed in a frame in view of selecting the bestperforming type. After this evaluation, the end fitting with the best performance was tested in a rig with dimensions according to Petrobras document I-ET 3500.00.6500-291-PAZ- 001 - Non standartized Prototype qualification tests of flexible pipes (2007). Tests performed in the frame and on the rig were monitored with resistance strain gages attached to wires of the external armor, on the interface with the end fitting resin, since performance of this region under fatigue is of utmost practical importance. Three-dimensional solid models were built using the Finite Element Modelling (FEM) method, as a way of validating experimental results. Comparison of results obtained from the different methodologies validated the numerical model, allowing a better understanding of the variations of stresses in the interface of the riser with the end fitting. This led to the solution of many doubts regarding fatigue performance as well as possible improvements in the design of flexible riser end fittings. Existing work published in literature considers only plane stress; the present study, based on 3D models which are not found in literature, is thought to better describe the stress concentration on the wires at the end fitting interface. The motivation of this work relies on the lack of detailed information of the stress and strain to which wires are subjected at the interface with the end fitting, as well as the importance of these in vital components for offshore oil exploration.
293

The effect of polymer materials on the fracture characteristics of high performance concrete (HPC)

Yahya, Mohmed Alkilani January 2015 (has links)
Compared with most construction materials, concrete is considered as a brittle material, and its brittleness increases with the compressive strength. For super-high-strength concrete, failure can be sudden, explosive and disastrous. Also the tensile strength is not proportionally increased. Therefore, it is necessary to carry out research on the brittleness of concrete in order to establish parameters for assessing the brittleness, find ways to improve the brittleness and tensile strength, and eventually design and manufacture concrete materials with high strength and low brittleness. In this study, strengthening and toughening effects of polymer materials on the high performance concrete (HPC) were investigated. The HPC was manufactured using ordinary Class 52.5 N Portland cement, silica fume and superplasticizer. The adopted polymers included the styrene-butadiene-rubber (SBR) latex, polyvinylidene chloride (PVDC), linear low density polyethylene (LLDPE) and high density polyethylene (HDPE) with contents of 1.5%, 3% and 5% in weight of cement content. The measured material and fracture properties included compressive and tensile strengths, modulus of rupture, Young's modulus, fracture energy, fracture toughness and brittleness. The test results at 28 days indicate that the addition of 1.5% and 3% SBR, PVDC, LLDPE and HDPE into the HPC could largely improve the compressive strength by up to 15.7%, while the addition of 5% SBR, LLDPE and HDPE did not show any enhancement except for 5% PVDC which increased the compressive strength by 10.9%. The tensile strength was considerably increased for all dosages of polymers, with the maximum increases of 72.7% and 83.2% for 3% SBR and 1.5% LLDPE, respectively. The fracture energy were also enhanced by adding 1.5% SBR and all dosages of LLDPE, with a maximum increase of 24.3%, while there were no indications of enhancement for other dosages of polymers. The modulus of rupture, fracture toughness and Young's modulus were not improved for lower dosages of polymers but slightly decreased for higher dosages. The brittleness decreased monotonically with increasing amount of LLDPE, but it increased with increasing amounts of SBR, PVDC and HDPE.
294

Ligaduras ortodônticas elastoméricas estéticas: alteração de cor, ultraestrutura da superfície (MEV) e propriedade elástica após uso de dentifrício clareador (estudo in vivo) / Esthetic orthodontic elastic ligatures: color change, ultra-structural surface (SEM) and elastic property after the use of whitening dentifrice (an in vivo study)

Leonardo Gontijo Matos 27 July 2017 (has links)
O objetivo desse estudo foi comparar o desempenho de ligaduras ortodônticas estéticas de 4 marcas comerciais, após 30 dias na cavidade bucal, com o uso de dentifrício clareador e convencional para avaliar: alteração de cor por meio da espectrofotometria; a ultraestrutura da superfície por meio da Microscopia Eletrônica de Varredura (MEV); propriedade elástica por meio do teste de tração. Foram avaliadas as ligaduras seguintes marcas comerciais: American Orthodontics, 3M Unitek, Orthotechnology e Morelli Ortodontia. Foram selecionados, após o cálculo amostral, 20 pacientes que atenderam aos critérios de inclusão. Os pacientes receberam, de forma aleatória, com o auxílio do acessório Shooter (TP Orthodontics, La Porte, IN, EUA) ligaduras nos elementos 13, 23, 33 e 43; 32, 31, 41 e 42. No mesmo dia receberam dentifrício clareador Colgate Luminous White (Colgate-Palmolive Indústria e Comércio, São Bernardo do Campo, SP, Brasil) que foi usado por 30 dias (grupo experimental). Após esse período as ligaduras foram removidas, armazenadas (em saliva artificial) e, imediatamente submetidas aos testes. Os pacientes receberam, então, dentifrício convencional Colgate Máxima Proteção Anti-cáries (Colgate-Palmolive Indústria e Comércio, São Bernardo do Campo, SP, Brasil) (grupo controle). Após 30 dias, foram removidas, armazenadas e submetidas aos ensaios. As ligaduras inseridas nos bráquetes dos caninos foram avaliadas para alteração de cor pelo espectrofotômetro (Vita Easyshade Zahnfabrik, Bad Säckingen, Alemanha). Em seguida, as ligaduras, de cada marca, que apresentaram maior e menor variação de cor com o dentifrício clareador e convencional, bem como ligaduras novas, foram submetidas à avaliação qualitativa com a visualização pelo Microscópio Eletrônico de Varredura (EVO 50, Carl Zeiss, Cambridge, Inglaterra). As ligaduras que estavam inseridas nos bráquetes incisivos inferiores foram submetidas ao teste de tração pela Máquina de Ensaio Mecânico Universal (EMIC DL 2000, São José dos Pinhais, PR, Brasil). Os achados foram submetidos à análise estatística ANOVA e ao teste complementar de Duncan em um nível de significância de 5%. Os resultados mostraram que o dentifrício clareador não conseguiu efetivamente manter a estabilidade de cor das ligaduras ortodônticas estéticas. O valor final para o ΔE (variação total de cor) para todas as marcas foi > 3,3 o que indica uma alteração clinicamente perceptível pelo olho humano e que sinaliza a reposição do material por razões estéticas. Em relação à MEV as imagens obtidas foram heterogêneas e não permitiram caracterizar um padrão para um ou outro dentifrício. No que se refere ao teste de tração, houve melhor desempenho para as marcas 3M Unitek e American Orthodontics. O tipo de dentifrício, clareador ou convencional, não alterou a propriedade elástica entre as marcas estudadas. Pode-se concluir, pela presente pesquisa, que o dentifrício clareador não foi capaz de alterar a estabilidade de cor nas 4 marcas avaliadas por um período de 30 dias. A avaliação qualitativa pela MEV não permitiu concluir se a abrasividade do dentifrício clareador trouxe danos ou injurias à superfície das ligaduras. Apesar disso, o seu uso não alterou a propriedade elástica das mesmas. / The objective of this study was to compare the performance of aesthetic orthodontic ligatures/modules of 4 commercial brands, after 30 days in the oral cavity, with the use of conventional and whitening dentifrice to evaluate: color change by spectrophotometry; the ultrastructure of the surface by Scanning Electron Microscopy (SEM); elastic property by the tensile test. The following brands were evaluated: American Orthodontics, 3M Unitek, Orthotechnology and Morelli Orthodontics. Twenty patients who were included in the inclusion criteria were selected after sample calculation. Patients received, at random, with the aid of the Shooter accessory (TP Orthodontics, La Porte, IN, USA) ligatures on elements 13, 23, 33, 43, 32, 31, 41 e 42 and whitening dentifrice Colgate Luminous White (Colgate-Palmolive Indústria e Comércio, São Bernardo do Campo, SP, Brazil), which was used for 30 days (test group). After this period, the ligatures were removed, stored (in artificial saliva) and immediately submitted to the tests. Patients were then given conventional toothpaste Colgate Maximum Anti-caries Protection (Colgate-Palmolive Indústria e Comércio, São Bernardo do Campo, SP, Brazil). This was the control group. Once again, after 30 days, the modules were removed, stored and submitted to assays. Ligatures inserted into the canine brackets were evaluated by the spectrophotometer (Vita Easyshade Zahnfabrik, Bad Säckingen, Germany) to evaluate the color change. After this step, the ligatures of each brand, which presented greater and lesser color variation, both with the whitening dentifrice as well as the conventional one, and new ligatures, were selected for qualitative evaluation with the visualization by the Scanning Electron Microscope (EVO 50, Carl Zeiss, Cambridge, England). The ligatures that were inserted in the lower incisor brackets were subjected to the tensile test by the Universal Mechanical Testing Machine (EMIC DL 2000, São José dos Pinhais, PR, Brazil). The findings were submitted to ANOVA statistical analysis and Duncan\'s complementary test at a significance level of 5%. The results showed that the whitening dentifrice failed to effectively improve the color stability of aesthetic orthodontic ligatures. The final value for ΔE (total color change) for all brands was > 3.3 which indicates a change clinically perceptible by the human eye and signaling the replacement of the material for aesthetic reasons. In relation to the SEM the images obtained were heterogeneous and did not allow to characterize a standard for one or the other dentifrice. Regarding the tensile test, there was better performance for the brands 3M Unitek and American Orthodontics. The type of dentifrice, whitening or conventional did not alter the elastic property between the brands studied. It can be concluded from the present research that the whitening dentifrice was not able to change the color stability in the 4 brands evaluated for a period of 30 days. The qualitative evaluation by SEM did not allow the conclusion that the abrasiveness of the whitening dentifrice caused damage to the surface of the ligatures. Despite this, their use did not alter their elastic property.
295

Resistência de união cerâmica - agente cimentante. Teste de micro-tração e análise por microscopia eletrônica de varredura

Faria, Ricardo Pinheiro de. January 2004 (has links)
Orientador: Leonor de Castro Monteiro Loffredo / Banca: Celso Luiz de Angelis Porto / Banca: Camila Pinelli / Banca: Rubens Corte Real de Carvalho / Banca: Adair Luis Stefanello Busato / Resumo: Os objetivos deste trabalho foram avaliar a influência de diferentes tempos de condicionamento ácido na resistência de união cerâmica-agente cimentante, por meio do teste de Micro-Tração, bem como análise dos modos de fratura. Foram confeccionados 5 pares de discos de cerâmica de infra-estrutura IPS Empress 2 e divididos aleatoriamente em 5 grupos. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação seqüencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: G1: sem condicionamento ácido; G2: 20 s de condicionamento com ácido fluorídrico a 10%; G3: 40 s e condicionamento com ácido fluorídrico a 10%; G4: 60 s de condicionamento com ácido fluorídrico a 10% e G5: 2 min de condicionamento com ácido fluorídrico a 10%. Os espécimes, aos pares, foram cimentados com um sistema adesivo e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 h a 37°C e, posteriormente, com auxílio de um disco de diamante perpendicular à superfície de união, "palitos" com 1 mmø de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS 800) e submetidos à análise de variância e teste de Tukey. As médias de resistência foram de 30,20 MPa, 36,19 MPa, 38,72 MPa, 41,43 MPa e 42,53 MPa, respectivamente aos grupos G1, G2 G3 G4 e G5. O grupo G1 apresentou menor resistência média de união do que os demais grupos. O grupo G3 teve comportamento semelhante a G2 e a G4, porém estes dois últimos foram diferentes entre si. Os grupos G4 e G5 promoveram resistências médias semelhantes. Concluímos que o aumento do tempo de condicionamento ácido aumentou os valores de resistência de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The purpose of this study was to investigate the effect of different times of acid conditioning on the microtensile bond strength between union-cement and ceramic, and to verify the mode of failure. Five pairs of ceramic disks (IPS Empress 2) were divided, in five groups, by randomized allocation. The bonding surfaces were finished with 600-grit silicon carbide paper. The specimens were nominated at random and submitted to the following treatments before cementation: G1 : without acid etching; G2 : 20 s of etching with 10% hydrofluoric acid; G3 : 40 s of etching with 10% hydrofluoric acid; G4 : 60 s of etching with 10% hydrofluoric acid and G5 : 2 min of etching with 10% hydrofluoric acid. All the pairs were bonded with dual cure resin bonding and dual cure resin cement, according to manufacturer's instructions. The specimens were light-cured and then stored for 48 h at 37°C. Using a diamond disk perpendicular to the bonding interface, 'sticks' with 1.0 mmø cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. It was applied analysis of variance and Tukey test at p<0.05. The means of microtensile bond strength, in MPa, were 30.20, 36.19, 38.72, 41.43 and 42.53, respectively to the groups G1, G2, G3, G4 and G5. Group G1 had the smallest microtensile bond strength and G3 had similar results when compared to G2 and G4, although G2 and G4 were different between themselves. The groups G4 and G5 showed similar means of microtensile bond strength. Conclusions: The higher the time of acid conditioning higher were the values of microtensile bond strength, and the analysis of mode of failure exhibited prevalence of adhesive failure type. / Doutor
296

Avaliação da vida em fadiga de um novo modelo de terminal conector para dutos flexíveis

Xavier, Flávio Galdino January 2009 (has links)
Este trabalho foca a avaliação da vida em fadiga de um novo modelo de terminal conector para dutos flexíveis (risers) de camadas não aderentes (unbonded). Os ensaios foram feitos levando em consideração apenas a parte estrutural desses dutos, de forma a ensaiar uma nova configuração de ancoragem da armadura de tração encontrada nesse equipamento conhecido como terminal conector (end fitting). É dentro deste componente que os arames da armadura de tração são fixados por resina epóxi em conjunto com uma configuração específica permitindo dessa maneira a sustentação do duto flexível quando fixado a plataformas offshore. Para a escolha do novo modelo de ancoragem aqui proposto, além de se tomar como referência, fez-se também uma analogia aos modelos utilizados nas ancoragens das barras metálicas utilizadas em concreto protendido. Isto foi feito por entender que algumas características mecânicas da resina epóxi aproximam-se das do concreto. Para a definição do novo modelo de ancoragem, uma análise simplificada, utilizando o Método dos Elementos Finitos (MEF), foi feita em dois modelos de ancoragens recomendados na API RP 17B (2002) e utilizado por alguns fabricantes, no intuito de verificar as distribuições das tensões ao longo desses arames dentro do terminal conector quando envolto pela resina epóxi. Esta análise destacou as regiões ao longo dos arames onde havia concentrações das tensões. Utilizando-se dessas informações, foi desenvolvida uma nova configuração para o arame dentro da resina de maneira a minimizar esses concentradores de tensão, permitindo assim que o modelo de ancoragem proposto tenha um melhor desempenho em fadiga. Para tanto, as verificações desses modelos feitas através do MEF e validadas através de ensaios experimentais em escala reduzida, mostraram que o modelo proposto apresentou reduções do KT da ordem de 16,5% e das tensões na resina de 60% quando comparados aos outros dois modelos comerciais. Após essas avaliações protótipos do novo terminal conector foram confeccionados em escala real e montado a dois pedaços de duto flexível de 2,5" de diâmetro, compondo assim dois corpos de prova: o CP1 e o CP2, os quais foram submetidos a ensaios de tração estáticos e carregamentos dinâmicos. Nos ensaios o CP1 foi submetido a uma carga máxima em tração de 844 kN e após esse carregamento, a não evidência de ruptura nos arames da armadura de tração o levou para o ensaio de fadiga com cargas em tração variando entre 130 e 304 kN a uma freqüência de 1Hz para uma vida de 1.000.000 de ciclos de carga. O resultado desse ensaio mostrou a viabilidade do conceito, uma vez que se atingiu a 1.000.000 de ciclos de carga sem a ruptura de qualquer arame dentro do terminal conector, evidenciado através da dissecação. Para finalizar os trabalhos, um segundo corpo de prova (CP2) foi confeccionado, obedecendo as recomendações estipuladas na API RP 17B (2002). Ensaiado com os mesmos parâmetros do CP1, se conseguiu levá-lo a fase de Dano igual a 1. Ao final desse ensaio observaram-se a ruptura de alguns arames na região mediana sobre o duto flexível que unia os dois conectores. Já as dissecações não mostraram evidências de arames rompidos internamente aos conectores. / This work focuses on the evaluation of the fatigue of life in a new model of end fitting for unbounded flexible pipe (risers). The tests had been made taking in consideration only the structural part of these risers, in order to test a new configuration of anchorage of the tensile armor found in equipment known as an end fitting. It is inside of this component that the tensile armor wires are fixed by epoxy resin in the set with specific configuration in this way allowing the sustentation these flexible pipes when the fixed offshore platforms. For the choice of the new model of anchorage considered here, beyond the reference if taking an analogy to the models used in the anchorage dues ones of the metallic bars used in prestressed concrete. This was made by understanding that some mechanical characteristics of the epoxy resin are come close to the concrete. For the definition of the new model of anchorage, the simplified analysis, using the Finite Element Method (FEM), was made in two models of anchorage dues recommended in API RP 17B (2002) and used by some manufacturers, in intention to verify the distributions tensions along the wires within of the end fitting when wrapped for the epoxy resin. This analysis highlighted the wires throughout the regions where it had concentrations of the tensions. Using these information of itself, a new configuration for the wire inside of the way resin was developed to minimize these concentrators of tension as soon as, allowing anchorage of the considered model one has better performance in fatigue. For in such a way, the verifications of these models made through the FEM and validated through experimental tests in reduced scale, had shown that the considered model presented reductions of the KT of the order of 16.5% and stress in the resin of 60% when compared with the others two commercial models. After these evaluations archetypes of connecting the new end fitting had been confectioned in real scale and mounted two pieces of flexible pipe of 2.5" of diameter, thus composing test of two bodies: the CP1 and the CP2, which had been submitted the static tension tests and dynamic loads tests. In the tests the CP1 was submitted to tension in the maximum load of 844 kN and after this shipment, the evidence of rupture in the wires of armor did not take the tension it for the tests of fatigue in traction with loads varying between 130 and 304 kN to the frequency of 1Hz for a life of 1,000,000 cycles of load. The result of this test showed the viability of the concept, that if the team reached the inside of 1,000,000 load cycles without the rupture of any wire of the end fitting, evidenced through the dissection. To finish the works, the body of the test (CP2) it was confectioned, obeying to the recommendations stipulated in API RP 17B (2002). Tested with the same parameters of CP1, were taken to the stage Damage equal to 1. To the end of this test they had observed it rupture of some wires in the region on the medium flexible pipe that joined the two end fittings. Already the dissections had not shown evidence of broken internally wires to the end fittings.
297

Desempenho energético de um trator agrícola 4x2 – TDA, em função da pressão de inflação dos pneus em pista de concreto e em solo mobilizado, conforme a norma OECD – código 2 / Energy performace of an agricultural tractor 4x2 TDA as a function of inflation pressure of tires on concrete surface and tilled soil, according to standard OECD-Code 2

Souza, Fábio Henrique de January 2013 (has links)
SOUZA, Fábio Henrique de. Desempenho energético de um trator agrícola 4x2 – TDA, em função da pressão de inflação dos pneus em pista de concreto e em solo mobilizado, conforme a norma OECD – código 2. 2013. 111 f. Dissertação (Mestrado em engenharia agrícola)- Universidade Federal do Ceará, Fortaleza-CE, 2013. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-06-21T18:16:56Z No. of bitstreams: 1 2013_dis_fhsouza.pdf: 2128560 bytes, checksum: 78b83c20c6855b47ac3b5dff81349d62 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-07-21T20:13:28Z (GMT) No. of bitstreams: 1 2013_dis_fhsouza.pdf: 2128560 bytes, checksum: 78b83c20c6855b47ac3b5dff81349d62 (MD5) / Made available in DSpace on 2016-07-21T20:13:28Z (GMT). No. of bitstreams: 1 2013_dis_fhsouza.pdf: 2128560 bytes, checksum: 78b83c20c6855b47ac3b5dff81349d62 (MD5) Previous issue date: 2013 / Agricult tractor adequation aiming the use of appropriated tire inflation pressures for different surface conditions results in better overall performance with consequent increase in operational capacity and better quality of service. Thus this study aimed to assess the energy performance of a farm tractor 4x2 - TDA working with different forces in the drawbar, inflation pressure of tires on concrete surface and tilled soil, using as a testing standard OECD – “Code 2" (2012). The tests were conducted at the Center for Testing Machines and Tires Agroforestry - NEMPA, a randomized 2x3x2 factorial and tracks with five repetitions, two tire inflation pressures Tractor 165.4 kPa (24 psi) in rear axles and 220.6 kPa (32 psi) front axles on the tractor, corresponding to maximum inflation pressure recommended by the tire manufacturer and 110.3 kPa (16 psi) in rear axles and 110.3 kPa (16 psi) in front wheelsets Tractor, corresponding to minimal inflation pressure recommended by the tire manufacturer, three forces applied to the drawbar 100%, 75% and 50% of the maximum force of traction at maximum power and rated speed of the engine and two types of bearing surfaces . These factors were arranged to allow evaluation of the effects of performance variables individually or in groups, with all data presented normality were subjected to analysis of variance, using the DMS test at 5% significance for the comparison of means, the data not normally distributed were arranged for statistical analysis by Exponentially Weighted Moving Average - MMEP. The tractor test was evaluated in the 7040 New Holland TM engine with maximum power specified by the manufacturer of 132 kW at 2200 rpm, pulling the Mobile Unit Testing in Drawbar - UMEB generated. In field trials showed that the minimum tire inflation pressure recommended by the tire manufacturer has improved the energy performance of the tractor, reducing specific consumption of fuel and increasing the yield on the tractor drawbar. In concrete surface the tractor got maximum tensile strength 32.6% higher than the maximum tensile strength obtained in surface soil mobilized. The test criteria employed the standard OECD - "Code 2" provided a standardized test in facilitating the comparison between the factors evaluated. / A adequação de um trator agrícola, visando utilização de pressões de inflação dos pneus adequadas, para diferentes condições superficiais de solo, resulta em melhor desempenho geral, com consequente aumento da capacidade operacional e melhor qualidade de operação. Assim este trabalho teve como objetivo avaliar o desempenho energético de um trator agrícola 4x2 - TDA trabalhando com diferentes forças na barra de tração, pressão de inflação dos pneus em superfície de concreto e em solo mobilizado, utilizando como norma de ensaio a OECD – “Código 2” (2012). Os ensaios foram realizados, no Núcleo de Ensaios de Máquinas e Pneus Agroflorestais – NEMPA, com delineamento experimental em faixas e esquema fatorial 2x3x2 com cinco repetições, sendo duas pressões de inflação dos pneus do trator 165,4 kPa (24 psi) nos rodados traseiro e 220,6 kPa (32 psi) nos rodados dianteiro do trator, correspondente a máxima pressão de inflação recomendada pelo fabricante dos pneus e 110,3 kPa (16 psi) nos rodados traseiro e 110,3 kPa (16 psi) nos rodados dianteiro do trator, correspondente a mínima pressão de inflação recomendada pelo fabricante dos pneus, três forças aplicadas na barra de tração 100%, 75% e 50% da força máxima de tração na potência máxima e velocidade nominal do motor e dois tipos de superfícies de rolamento. Esses fatores foram arranjados para permitir a avaliação dos efeitos das variáveis de desempenho individualmente ou em grupos, sendo todos os dados que apresentaram normalidade foram submetidos à análise de variância, aplicando o teste DMS a 5% de significância, para a comparação das médias, os dados que não apresentaram distribuição normal foram arranjados para analise estatística através da Média Móvel Exponencialmente Ponderada - MMEP. O trator avaliado no ensaio foi o New Holland TM 7040 com potência máxima no motor indicada pelo fabricante de 132 kW a 2200 rpm, tracionando a Unidade Móvel de Ensaio na Barra de Tração - UMEB. Nos ensaios de campo observou-se que a mínima pressão de inflação dos pneus recomendada pelo fabricante dos pneus melhorou o desempenho energético do trator, reduzindo o consumo especifico de combustível e aumentando o rendimento na barra de tração do trator. Em superfície de concreto o trator obteve força máxima de tração 32,6% superior à força máxima de tração obtida em superfície de solo mobilizado. Os critérios de ensaio empregados da norma OECD - “Código 2” proporcionaram uma padronização no ensaio facilitando a comparação entre os fatores avaliados.
298

Emprego de cabos de aço como armadura de tração para a aplicação em dutos flexíveis

Fontana, Walter Andrey January 2013 (has links)
A necessidade de exploração de petróleo em águas profundas exige o emprego de dutos flexíveis com desempenho em fadiga adequado, sendo as armaduras de tração deste tipo de duto as camadas mais críticas para este tipo de solicitação. Atento a isto, este trabalho mostra o desenvolvimento de um novo conceito de armaduras de tração, que são construídas com cabos de aço. Para avaliar o desempenho dos cabos de aço na armadura tração foi elaborada uma configuração de armadura, com a seleção e aplicação de cabos de aço disponíveis no mercado nacional. Além da caracterização metalúrgica, dimensional e mecânica, foram feitos ensaios de fadiga ao ar e em água do mar sintética no cabo de aço selecionado. Ensaios em fadiga de uma seção da conexão foram feitos para avaliar as características da falha de fadiga, comparando-as com os tendões maciços. Também foi executada uma análise por elementos finitos para avaliar a distribuição de tensões no interior da resina, sendo validada pelo uso de extensômetros no cabo. Foi projetado e construído um duto com a configuração proposta, além das conexões. Este duto foi ensaiado em tração e fadiga e comparado com um duto de referência, em termos de peso, tensões e rigidez axial e a flexão. Os resultados sugerem um grande aumento na vida em fadiga nas conexões e no ambiente com água do mar. Além disso, o duto construído suportou com sucesso todos os modos de carregamento impostos ao duto de referência, superando o número de ciclos deste. As análises de falha indicaram que o duto desenvolvido apresentou o modo de fratura dúctil, enquanto que os ensaios com as seções da conexão indicaram sinais de fadiga em regiões com falha superficial dos fios. A rigidez axial é similar ao do duto de referência e a rigidez a flexão calculada é superior ao do duto de referência devido ao maior diâmetro das camadas das armaduras. Apesar do maior peso do duto desenvolvido, a resistência específica é similar. / The need for oil exploration in deep water requires the use of flexible pipes with better fatigue performance, and the tensile armor of this type of product layers critical for this type of application. Aware of this, this work shows the development of a new concept of tensile reinforcement, which are built with wire ropes. To evaluate the performance of wire ropes in tensile armor, an armor configuration was developed, with the selection and application of steel cables available in the domestic market. Besides metallurgical characterization, dimensional and mechanical fatigue tests were carried out in air and in synthetic sea water on wire rope selected. Fatigue tests on end-fitting section were made to evaluate the characteristics of fatigue failure, compared with the massive tendons. It has also been performed by finite element analysis to evaluate the stress distribution within the resin, being validated by the use of strain on the wire rope. It was designed and constructed a pipeline with the proposed configuration, in addition to connections. This pipeline was tested in tensile and fatigue compared to a reference pipeline in terms of weight, axial and flexural stiffness and axial tension. The results suggest a large increase in fatigue life on end-fitting and the environment with seawater. Furthermore, the flexible pipe developed successfully endure all modes of loading imposed on the reference pipe, surpassing the number of cycles thereof. The failure analysis indicated that the flexible pipe developed showed ductile fracture mode, while the trials with boxes indicated signs of fatigue failure in the regions with the surface of the wires. The axial stiffness is similar to the reference pipeline and the flexural stiffness calculated is higher than the reference product, due to the greater diameter of the layers of armor. Despite the greater weight of the product developed, the specific resistance is similar.
299

Influência de primers dentinários modificados por digluconato de clorexidina na resistência de união de pinos de fibra de vidro em dentina radicular / Influence of modified dentin primers containing chlorexidine digluconate on bond strenght of glass-fiber posts to radicular dentin

Canineo, Simone Yumi Sudo [UNESP] 07 August 2018 (has links)
Submitted by Simone Yumi Sudo (simonesudo.unicamp@yahoo.com.br) on 2018-09-29T20:47:10Z No. of bitstreams: 1 Dissertação finalizada para impressão.pdf: 2678021 bytes, checksum: c5e33b2838958ac33bc085b7b664e62f (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-10-03T13:41:02Z (GMT) No. of bitstreams: 1 canineo_sys_me_sjc.pdf: 2678021 bytes, checksum: c5e33b2838958ac33bc085b7b664e62f (MD5) / Made available in DSpace on 2018-10-03T13:41:02Z (GMT). No. of bitstreams: 1 canineo_sys_me_sjc.pdf: 2678021 bytes, checksum: c5e33b2838958ac33bc085b7b664e62f (MD5) Previous issue date: 2018-08-07 / O estudo avaliou in vitro o efeito da modificação de primers dentinários com digluconato de clorexidina na resistência de união de pinos de fibra de vidro em dentina radicular. A hipótese testada considerou que a incorporação de clorexidina em primers dentinários não interferiria na resistência de união de pinos de fibra de vidro independentemente da profundidade da dentina radicular testada imediatamente e após envelhecimento. Sessenta raízes retilíneas bovinas foram selecionadas e divididas aleatoriamente em 6 grupos (n=10). As raízes foram obturadas e os condutos preparados de modo sequencial e padronizado para receber os pinos de fibra de vidro que foram silanizados previamente. A dentina radicular foi condicionada com ácido fosfórico 37% por 15s, seguido da aplicação do primer do sistema adesivo convencional ou primer modificado, seguido da aplicação do adesivo dentinário. Os primers experimentais foram preparados, incorporando solução aquosa ou alcóolica de clorexidina com concentração de 0,12%. O cimento resinoso dual foi inserido no interior das raízes e os pinos posicionados para fotoativação durante 40s. Para determinar a resistência de união, metade das amostras foram cortadas transversalmente em 3 secções em diferentes profundidades da dentina radicular, e testadas imediatamente por push-out, em uma máquina de ensaios universal (EMIC), com célula de carga de 100Kgf e velocidade de 1mm/min. A outra metade das amostras receberam reconstrução coronária com resina composta direta, por meio de matrizes de silicone padronizadas e teve o ligamento periodontal reproduzido com poliéter para submeter ao envelhecimento em ciclagem termomecânica sob cargas de 88N em 1.200.000 ciclos, com frequência de 3,8Hz e então submetidas ao teste de push-out. As superfícies fraturadas foram analisadas em estereomicroscópio e apenas as fraturas adesivas foram selecionadas para análise estatística. Os resultados foram convertidos em MPa e submetidos ao teste ANOVA 3-fatores, seguido do teste Tukey para contraste das médias em nível de significância (p<0,05). Os resultados obtidos indicaram não haver diferenças estatísticas da resistência de união entre os grupos com ou sem clorexidina e entre os grupos envelhecidos ou não (p>0,05). Houveram diferenças estatisticamente significantes entre as regiões cervicais, médias e incisais testadas entre si (p<0,05). Concluiu-se que a incorporação de clorexidina em primers dentinários não interferiu na resistência adesiva imediata e na estabilidade após envelhecimento de pinos de fibra de vidro à dentina radicular, independentemente da profundidade analisada. Mas evidenciou-se que a medida que se aumenta a profundidade (cervical para apical) os valores de resistência adesiva diminuem para todos os protocolos de cimentação adotados. / The present in vitro study evaluated the influence of modified dentin primers containing chlorhexidine digluconate on bond strength of glass fiber posts to radicular dentin. The hypothesis to be tested considers that the incorporation of chlorexidine in dentin primers does not interfere on the bond strength of glass fiber posts independently of the analyzed radicular dentin depth tested immediately or after thermocycling aging. Sixty rectilinear bovine roots were selected and randomly distributed into 6 groups (n=10). The endodontically treated root canals were sequentially and standardized prepared for glass-fiber posts insertion, which were previously silanized. The radicular dentin was etched with 37% phosphoric acid for 15s and conditioned using the conventional primer or the modified primer followed by the corresponding adhesive. Experimental primers were prepared by adding aqueous or alcoholic solutions of chlorexidine to obtain a 0.12% concentration. A dual- cured resin cement was inserted into the root canals and the posts were positioned for light polymerization for 40s.To measure the bond strength, half of the samples were transversally sectioned into 3 slices from different radicular regions, and immediately processed for push-out test into an universal test machine (EMIC), with a load-cell of 100Kgf, and at a speed of 1mm/min. The other half a coronary reconstruction was conducted with composite resin, based on a standardized silicon matrix. The periodontal ligament was reproduced with polyether to undergo the aging by thermo mechanical cycling, with 88N load in 1 in 1.200,000 cycles, with a 3.8Hz frequency and then submitted to push-out test. The fractured surfaces were analyzed under a stereomicroscope and only adhesive fractures were selected for statistical analysis. The results were converted to MPa and submitted to a 3-way ANOVA test followed by Tukey test for mean contrasts to the level of significance (p<0,05). The measurements showed no significant differences for bond strength values between groups treated with or without chlorexidine and between groups with or without aging (p>0,05). Significant differences (P<0.05) were observed between the cervical, middle and apical regions. It was concluded that the incorporation of chlorexidine in dentin primers did not interfere in the immediate bond strength and in the post-aging stability of glass fiber posts in the radicular dentin, regardless of the analyzed depth. Nevertheless, it was demonstrated that, as the depth was increased (cervical to apical), the values of adhesive resistance decrease for all adopted cementation protocols.
300

Influência da variação da intensidade de luz, para uma mesma exposição radiante, no comportamento mecânico de uma resina convencional e de uma resina de baixa contração / Influence of photoactivation modes, with the same radiant exposure, on mechanical properties of a convencional and a low-shrinkage composite

Mariana Rodrigues Gonzalez 08 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo teve como objetivo avaliar a influência da variação da intensidade de luz, para uma mesma exposição radiante, na resistência à flexão, na microdureza e na resistência à tração diametral de uma resina convencional e de uma resina de baixa contração. Para a confecção dos corpos de prova foram utilizadas as resinas Filtek Z250 (3M ESPE) e Filtek P90 LS (3M ESPE) fotoativadas por meio dos seguintes protocolos: Convencional (400mW/cm por 60 s), Média intensidade (700mW/cm por 34 s) e Alta intensidade (950mW/cm por 26 s). Todos os corpos de prova receberam a mesma exposição radiante de 24J/cm. A resistência à flexão foi avaliada por meio do ensaio de flexão três pontos. Para este ensaio foram confeccionados trinta corpos de prova de cada material (n=10) com dimensões de 10mm x 2mm x 1mm. A avaliação da microdureza Knoop foi obtida a partir de seis discos de cada resina com 5mm de diâmetro por 2mm de espessura (n=2), sendo realizadas cinco indentações em cada espécime. Trinta corpos de prova cílindricos de cada compósito (n=10) com 3mm de diâmetro por 6mm de altura foram confeccionados para a realização do teste de tração diametral. A análise estatística dos resultados obtidos foi realizada por meio do teste de análise de variância (ANOVA) e do teste de múltiplas comparações de Tukey (p < 0.05). A resistência à flexão da resina P90 não foi influenciada de forma significativa pelas diferentes formas de ativação, enquanto a Z250 obteve resultados significantemente maiores para o protocolo de alta intensidade em relação ao convencional. Em todas as intensidades de luz, os resultados da Z250 foram significativamente maiores que os da P90. A microdureza da resina P90 foi estatisticamente maior para o grupo de média intensidade em relação aos outros, já a Z250 não obteve resultados com diferença estatística em relação às formas de ativação. Para a mesma irradiância, a Z250 obteve maiores valores de microdureza do que a P90, com exceção para o protocolo de média intensidade em que não houve diferença estatística entre os materiais. Os valores de resistência à tração não foram influenciados de forma significativa nem pelas diferentes intensidades de luz, nem pelos materiais utilizados. A influência da variação da intensidade de luz depende do tipo de compósito utilizado e da propriedade mecânica avaliada. / This study has the purpose of evaluating the variation of the intensity of light, for a constant radiation exposure, for flexural strength, for microhardness, and for tensile strength, of a conventional composite and a low shrinkage composite. The test samples were made of Filtek Z250 (3M ESPE) e Filtek P90 LS (3M ESPE) light-activated composites. The following light activating protocol was used: conventional (400mW/cm for 60 s); medium intensity (700mW/cm for 34 s), and high intensity (950mW/cm for 26 s). All of the test samples received the same radiation exposure of 24J/cm. The flexural strength was measured through the three-point bending test. For this test, thirty especimens were made for each material (n=10), measuring 10mm x 2mm x 1mm. The Knoop hardness evaluation was carried out using six discs of each composite measuring 5mm in diameter, and 2mm in height (n=2), with five indentations in each specimen. Thirty cylindrical test samples of each composite (n=10) measuring 3mm in diameter, and 6mm in height were obtained for the diametral tensile test. The statistical analysis of the results was carried out through analysis of variance test (ANOVA) and through Tukeys multiple comparisons test (p < 0.05). The P90 composite flexural strength was not significantly influenced by the different activating methods, while Z250 achieved significantly higher values for the high intensity protocol when compared to the conventional one. For all light intensities, the Z250 results were higher than those for P90. P90's microhardness was statistically higher for the medium intensity group when compared to the others, whereas Z250's results had no statistical difference for the different activating protocols. For the same irradiation, Z250 presented higher values for microhardness than P90, except for the medium intensity protocol, which had no statistical difference between the different materials. The tensile strength values were not significantly influenced neither by the different light intensities, nor by the materials. The influence of the variation of light intensity depends upon the type of composite, as well as the mechanical property to be evaluated.

Page generated in 0.0411 seconds