• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 385
  • 336
  • 86
  • 52
  • 37
  • 21
  • 18
  • 14
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • Tagged with
  • 1168
  • 506
  • 236
  • 225
  • 221
  • 181
  • 177
  • 157
  • 152
  • 118
  • 109
  • 101
  • 97
  • 94
  • 94
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Estudo do efeito da radiação por feixe de elétrons nas propriedades de filmes de copoliester alifático aromático / Study of the electron beam irradiation effect on some properties of aromatic aliphatic copolyester films

POVEDA, PATRICIA N.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:59Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
322

Estudo comparativo do condicionamento do esmalte e dentina para a adesao de resinas compostas com os lasers Er:YAG 2,94 micrometros e com o laser Co sub(2) de 9,6 micrometros

MARRACCINI, TARSO M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:33Z (GMT). No. of bitstreams: 1 08291.pdf: 5207950 bytes, checksum: 64c6335bc7b19848a3ba260e8b738aeb (MD5) / Dissertacao (Mestrado) / IPEN/D / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP
323

Avaliação da resistência a micro-tração da resina composta no esmalte após clareamento dental. Influência da irradiação com o laser de Er:YAG e o tipo do sistema adesivo

PINHEIRO, LAURA F.M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:16Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:28Z (GMT). No. of bitstreams: 1 12725.pdf: 694845 bytes, checksum: 870ef073a546859ba2181fc3116ba9fe (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo
324

Texturização em superfícies de titânio grau 2 irradiadas com laser de pulsos ultracurtos / Texturing in titanium grade 2 surface irradiated with ultrashort pulse laser

NOGUEIRA, ALESSANDRO F. 11 June 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-06-11T17:54:41Z No. of bitstreams: 0 / Made available in DSpace on 2015-06-11T17:54:41Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
325

Influência do teor de hidrogênio no gás de proteção sobre as propriedades mecânicas de juntas soldadas do aço ASTM A-36

Silva, Roneles de Santana 11 December 2013 (has links)
Made available in DSpace on 2015-05-08T14:59:53Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 3656231 bytes, checksum: 91c88d760baaa97002fc6dc818b5a4e5 (MD5) Previous issue date: 2013-12-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This is work study about Conducted, to investigate the influences of hydrogen content of the shielding gas in the behavior of mechanical properties (toughness, hardness, and tensile strength) of steel welded ASTM A36. The test specimens were welded with GMAW and FCAW. That is, we used two mixtures of shielding gas, 75% Ar +25% CO2 in the other containing hydrogen in its composition, 70% Ar +25% CO2 +5% H2. The development experiment was carried out in the completely random with the aid of a procedure known as factorial design (FT), having been used for the variables influencing the type of wire, and gas composition. The replies variables were analyzed tensile strength, toughness and hardness regions of the weld. The results were submitted to analysis variance and 90% confidence interval was utilized. The technique of scanning electron microscopy (SEM) was used to characterize the fracture mode observed in the weld metal and in the thermally affected by the heat. The results showed the hydrogen present in the shielding gas brittled the weld metal, and which were observed bubble formation in the weld metal. / Nesse trabalho foi realizado um estudo para avaliar a influência do teor de hidrogênio do gás de proteção no comportamento das propriedades mecânicas (tenacidade, dureza, resistência a tração) de juntas soldadas do aço ASTM A-36. As juntas foram soldadas com os processos MIG/MAG e Arame tubular. Para isso utilizou-se duas misturas de gás de proteção, 75%Ar+25%CO2 é a outra contendo hidrogênio na sua composição, 70% +25%CO2 +5%H2. O desenvolvimento experimental foi realizado de forma totalmente aleatória, com o auxílio de um procedimento conhecido como planejamento fatorial (PF); foram utilizados como variáveis de influencia o tipo de arame, e a composição do gás. Como variáveis de resposta foram analisadas a resistência a tração, a tenacidade e a dureza das regiões da junta soldada. Os resultados foram submetidos à análise de variância e validado para uma confiança de 90%. A técnica de microscopia eletrônica de varredura (MEV) foi usada para caracterizar os modos de fratura observados no metal de solda e na zona termicamente afetada pelo calor. Os resultados mostraram que o hidrogênio presente no gás de proteção fragilizou o metal de solda (MS), e que houve a formação de bolhas no metal de solda.
326

Correlação entre viscosidade e propriedades mecânicas de polpas kraft em sequências de branqueamento livres de cloro elementar / Correlation between viscosity and mechanical properties of kraft pulps in elemental chlorine free bleaching sequences

Ferraz, Ana Paula Almeida 27 February 2018 (has links)
Submitted by Ana Paula Almeida Ferraz (ana.almeida.ferraz@gmail.com) on 2018-04-16T15:45:49Z No. of bitstreams: 1 Ana Paula Almeida Ferraz.pdf: 1528848 bytes, checksum: efac2d5c50a3b2eb9d3d5b0b7e2e6a11 (MD5) / Approved for entry into archive by Pamella Benevides Gonçalves null (pamella@feg.unesp.br) on 2018-04-16T19:14:08Z (GMT) No. of bitstreams: 1 ferraz_apa_me_guara.pdf: 1528848 bytes, checksum: efac2d5c50a3b2eb9d3d5b0b7e2e6a11 (MD5) / Made available in DSpace on 2018-04-16T19:14:08Z (GMT). No. of bitstreams: 1 ferraz_apa_me_guara.pdf: 1528848 bytes, checksum: efac2d5c50a3b2eb9d3d5b0b7e2e6a11 (MD5) Previous issue date: 2018-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente estudo tem por objetivo elucidar sobre a correlação entre a viscosidade e as propriedades mecânicas da polpa. O material utilizado foi uma amostra de Eucalyptus grandis x Eucalyptus urophylla. Os cavacos foram submetidos a cozimentos com tempos de polpação de 90 e 120 minutos. Para as polpas produzidas com tempo de 90 minutos, realizou-se a deslignificação com oxigênio com temperatura de 95°C e para as polpas produzidas com o tempo de 120 minutos, a temperatura do estágio de deslignificação com oxigênio foi de 115°C, objetivando uma maior diferença de viscosidade entre as amostras. Ambas as polpas foram branqueadas a partir das sequências ECF OD(E+P)DD, OAHTD(E+P)DP e OD(E+P)(PO). Posteriormente as polpas foram refinadas em moinho PFI e avaliadas quanto ao índice de rasgo, tração e arrebentamento, segundo as normas da TAPPI (Technical Association of the Pulp and Paper Industry). Os resultados indicam que o aumento do tempo de cozimento em 30 minutos e aumento da temperatura da deslignificação com oxigênio de 95°C para 115°C afetam significativamente a viscosidade da polpa. O refino foi afetado pela diminuição da viscosidade das sequências produzidas com deslignificação com oxigênio à temperatura de 115°C. O índice de rasgo apresentou decréscimo quanto menor a viscosidade da polpa em todas as sequências de branqueamento deste estudo. Os índices de tração e arrebentamento apresentaram decréscimo de acordo com a diminuição da viscosidade em uma mesma sequência, entretanto, quando a comparação foi feita entre diferentes sequências de branqueamento, não houve relação entre os índices de tração e de arrebentamento com a viscosidade da polpa. / This study aims to elucidate the correlation between the viscosity and the mechanical properties of the pulp. The material used was a sample of Eucalyptus grandisx Eucalyptus urophylla. The chips were cooked with cooking times of 90 and 120 minutes. For the pulps produced in 90 minutes, the delignification with oxygen at temperature of 95ºC was performed and for the pulps produced in 120 minutes, the temperature of the oxygen delignification stage was 115ºC, aiming a greater difference of viscosity between the samples. Both pulps were bleached from the sequences ECF OD(E+P)DD, OD(E+P)(PO) and OAHTD(E+P)DP. Later, the pulps were refined in PFI mill and assessed for the tear, tensile and burst indexes, according to the TAPPI (Technical Association of the Pulp and Paper Industry) standards. The results indicate that the increase of cooking time in 30 minutes and the increase of temperature in oxygen delignification from 95°C to 115°C affect significantly the pulp viscosity. The refining was affected by the viscosity reduction of the sequences produced with delignification with oxygen at temperature of 115ºC. Tear index decreased as the pulp viscosity was lower, in all the bleaching sequences. Tensile and burst indexes presented decrease with the decrease of the viscosity in the same sequence, however, when comparing different bleaching sequences, there was no relation between the tensile and burst indexes with the pulp viscosity.
327

Avaliação "in vitro" da resistência de união em dentina irradiada com o laser de Er:Yag, mediante a aplicação de diferentes sistemas adesivos /

Guzmán Sierpinski, Liz Marie. January 2002 (has links)
Resumo: O objetivo deste trabalho foi avaliar a influência que o laser de Er:YAG exerce sobre a resistência de união do material restaurador ao substrato dentinário, associando-se a diferentes sistemas adesivos. Para isto foram avaliados 30 molares humanos livres de cárie divididos em três grupos experimentais, utilizando o laser de Er:YAG com uma energia de 260 mJ/10Hz e três grupos controles, em que foram aplicados os seguintes tratamentos: G1) laser, ácido fosfórico a 37%, Excite/Vivadent; G2) controle, ácido fosfórico a 37%, Excite/Vivadent; G3) laser, sistema adesivo Prompt L-pop/Espe; G4) controle, Prompt L-pop;/Espe; G5) laser, ácido fosfórico a 37%, Single Bond/3M; G6) controle, ácido fosfórico a 37%, Single Bond/3M. Todas as amostras foram restauradas com a resina composta Tetric Ceram/Vivadent, termocicladas em 550 ciclos e cortadas, obtendo-se espécimes de mais ou menos 1mm,2 para serem levados a uma Máquina de Testes Universal onde foi realizado o ensaio de microtração. Os tipos de fraturas ocorridos foram analisados mediante microscopia óptica digital e as fraturas mais representativas foram levadas à microscopia eletrônica de varredura. Os resultados mostraram que o sistema laser de Er:YAG apresentou as menores médias de tensão de ruptura, independente do sistema adesivo utilizado. O sistema adesivo Prompt l-pop mostrou resistência adesiva estatisticamente menor em relação aos outros sistemas adesivos estudados. Não houve diferença estatística entre os sistemas adesivos Single Bond e Excite. A maior parte das fraturas encontradas para todos os grupos foram do tipo adesiva. / Abstract: The aim of this study is to evaluate the influence of the laser Er:YAG to the junction resístance between the tooth surface and the restorative material , using different adhesives . For this study were used 30 human healthy molars, divided in three experimental groups and three control groups. The experimental groups were exposed to a laser of Er:YAG with 260 mJ/10Hz of energy. The six groups were: G1) laser, phosforic acid at 37%, Excite/ Vivadent. G2) control, phosforic acid at 37 % , Excite/ Vivadent. G3) laser, adhesive system Prompt L-pop/ Espe. G4) control, adhesive system Prompt L-pop/ Espe. G5) laser, phosforic acid 37% , Single Bond/ 3M. G6) control, Single Bond/ 3M. All the teeth were restored with the composite Tetric Ceram/ Vivadent. Then thermocycled 550 times and cut in specimens of 1mm2. In these specimens was made a test of micro tensile bond strength in a Universal Test Machine. The fractures were analyzed in a digital optical microscope, and more representative fractures were then analyzed in a electronic microscope. The results revealed that the groups treated with laser Er:YAG presented less tensile bond strengh, independently to the adhesive system used. The adhesive Promp 1-pop presented less tensile bond strengh compared to the other adhesives evaluated. There no was difference between the groups of Single Bond and Excite. The fractures more commun were the adhesive type. / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Vanderlei Salvador Bagnato / Banca: Osmir Batista de Oliveira Júnior / Banca: Alberto Magno Gonçalves / Mestre
328

Desempenho adesivo de sistemas de união à dentina aplicados in vivo e in vitro : efeito da pressão intrapulpar e profundidade dentinária /

Hebling, Josimeri. January 2006 (has links)
Resumo: O objetivo do presente estudo foi investigar a influência da pressão intrapulpar e da profundidade dentinária sobre o desempenho adesivo de dois agentes de união à dentina, Single Bond (3M ESPE, St. Paul, MN, EUA) e Clearfil SE Bond (Kuraray, Tokyo, Japão), aplicados in vitro e in vivo. Quarenta e oito prémolares superiores hígidos foram selecionados e os pares pertencentes aos mesmos pacientes foram aleatoriamente distribuídos em 4 grupos experimentais de acordo com o sistema adesivo e a pressão intrapulpar, presente ou ausente. Dos dentes pertencentes ao mesmo par, um foi tratado in vivo e o outro in vitro. A ausência ou presença de pressão intra-pulpar foi determinada in vivo pelo uso de anestésicos locais com ou sem vasoconstritor, respectivamente. In vitro, os dentes foram mantidos sob pressão hidrostática de 15 cm de água por 24 horas. Cavidades de classe I foram preparadas e os sistemas adesivos aplicados de acordo com a recomendação dos fabricantes, seguidos da restauração incremental em resina composta. Para os dentes tratados in vitro, os mesmos procedimentos restauradores foram realizados após 6 meses de armazenagem em solução contendo timol 0,1%. Espécimes com área de secção transversal de 1 mm2 foram obtidos e submetidos ao ensaio mecânico de microtração. In vivo, ambos os sistemas adesivos apresentaram desempenho adesivo comparável, enquanto in vitro, o sistema Single Bond foi superior ao sistema Clearfil SE Bond. Esse último não foi influenciado por nenhuma das variáveis estabelecidas no estudo, ou seja, aplicação in vitro ou in vitro, presença de pressão intrapulpar e profundidade em dentina. O sistema Single Bond aplicado sob pressão intrapulpar positiva sofreu variação significante de resistência de união em função da profundidade da dentina, ou seja, em dentina profunda seu desempenho adesivo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the influence of intrapulpal pressure and dentin depth on bond strength of an etch-and-rinse and a self-etching bondin agent to dentin in vitro and in vivo. Twenty-four pairs of sound upper premolars were randomly divided into four groups (n=6) according to the dentin bonding agent, Single Bond (3M ESPE, St. Paul, MN, EUA) and Clearfil SE Bond (Kuraray, Tokyo, Japan), and the presence or absence of intrapulpal pressure. Each tooth of the pair from the same subject was further designated to be treated in vivo or in vitro. The intrapulpal pressure was controlled in vivo by the delivery of local anesthetics containing or not a vasoconstrictor. The in vitro intrapulpal pressure was achieved by keeping the teeth under a hydrostatic pressure (15 cm H2O) for 24 h. Class I cavities were prepared and the dentin bonding agents applied according to the manufacturers' directions, followed by the incremental resin restoration. For the teeth treated in vitro, the same restorative procedures were performed after 6 monthstorage in 0.1% tymol. Beams with 1 mm2 cross-sectional area were prepared and microtensile tested. The dentin bonding agents produced similar bond strengths when applied in vivo, while Single Bond performed better in vitro. Only the latter was influenced by the presence of intrapulpal pressure, however this was significant only when the bond strengths were stratified according to the dentin depth. This means that in deep dentin, the adhesive performance of this bonding agent was significantly inferior compared to superficial dentin, both in vitro and in vivo. In conclusion, the intrapulpal pressure did not influence the ability of the self-etching bonding agent to bond to dentin as well as its application in vivo or in vitro. The etch-and-rinse adhesive, on the other hand, performed better in vitro and was negatively... (Complete abstract click electronic access below)
329

Influência do tipo de tratamento superficial na força adesiva do reparo com resina composta em materiais estéticos /

Ahid, Fernando Jorge Mendes. January 2003 (has links)
Orientador: Welingtom Dinelli / Banca: Luís Geraldo Vaz / Banca: Marcelo Ferrarezi de Andrade / Banca: Edson Alves de Campos / Banca: Paulo Sérgio Quagliatto / Resumo: Avaliou-se a influência do tipo de tratamento da superfície de materiais estéticos no processo de adesão do reparo com resina composta, por meio do teste de cisalhamento. Foram preparados 360 corpos-de-prova, sendo 120 em cerâmica, 120 em resina composta e 120 em cerômero os quais receberam 06 tipos de tratamentos de superfície a saber, ponta diamantada (GT1C), ponta diamantada e silano (GT1S), jato abrasivo (GT2C), jato abrasivo e silano (GT2S), ácido hidrofluorídrico (GT3C) e ácido hidrofluorídrico e silano (GT3S). O adesivo do Sistema Scotchbond Multipurpose Plus, silano e resina composta Z100 foram aplicados sobre a superfície e os corpos-de-prova armazenados à temperatura de 37oC, por 24 horas, ciclados e novamente armazenados, para em seguida serem cisalhados. A análise estatística dos resultados mostrou que não houve diferença estatística na resistência adesiva dos reparos em resina composta e cerômero, porém, para o material cerâmico, o silano foi eficiente para aumentar a resistência para os tratamentos mecânicos T1 e T2, entretanto, o T3, com ou sem silano, apresentou resistência maior. Os tipos de fraturas foram 100% coesiva do substrato (CS). A microscopia mostrou superfícies com características diferentes para cada material e tratamento superficial. Concluindo os valores de resistência adesiva para a cerâmica sofreram influência do tipo de tratamento e que estes não influenciaram os materiais resinosos. / Abstract: The influence of the types of the surface treatment in esthetic materials in adhesive process, was evaluaed through shear strength test. The samples were constructed and polished, that received the treatment with diamond bursh (GT1C), and silane application (GT1S), jet of abrasive air (GT2C), and silane application (GT2S), hydrofluoric acid gel (GT3C) and silane application (GT3S). The adhesive of Scotchbond Multiporpose Plus System, the silane and Z100 composite resin were applied on this surface and the whole resin/substract was stored to the temperature of 37o.C, for 24 hours. They were thermocicled, stored again and tested in tension. The static analyses of results showed there is not difference in adhesive resistence of repair between composite resin and ceromero, however in ceramic, the silane increased the resistance in T1 and T2. The T3 group silanated and non silanated was observed increase of resistance. The types of fractures that occurred were 100% cohesive. Scanning electronic microscopy analysis revealed different surfaces in differentes estetic materials and diferents types de surface treatments. The present study showed that adhesive resistence of ceramic repair were affected for the type of surface treatment. However the type of surface tratment didn't affected the adhesive resistence of other materials. / Doutor
330

Resistência à flexão, resistência à tração diametral e dureza de sistemas cerâmicos para infra-estrutura /

Schalch, Max von. January 2003 (has links)
Orientador: Carlos Alberto dos Santos Cruz / Banca: Renata Garcia Fonseca / Banca: Alma Blásida Concepción Elizaur Benitez Catirse / Resumo: O objetivo deste estudo foi comparar a resistência à flexão, a resistência à tração diametral e a dureza do material de infra-estrutura dos sistemas cerâmicos IPS-Empress 2/Ivoclar (dissilicato de lítio, processado por injeção) e In-Ceram Zirconia/Vita (óxidos de alumínio e zircônio, processados por dupla sinterização). Foram confeccionadas dez amostras de cada material para o ensaio de flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872) e 15 amostras para o ensaio de tração diametral (em forma de disco, 6mm de diâmetro, 3mm de espessura). Os testes foram realizados em equipamento MTS 810 (Material Test System - EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada cerâmica foram incluídos em resina acrílica autopolimerizável JET (Artigos Odontológicos Clássico, Brasil), polidos e submetidos ao teste no durômetro Buheler (EUA), com carga de 1,0kgf por 30 segundos. Os resultados mostraram maior resistência à flexão do material In-Ceram Zirconia (439,88MPa) em relação ao IPS-Empress 2 (226,13MPa). Entretanto, observou-se maior resistência à tração diametral do IPS-Empress 2 (175,08MPa) em relação ao In-Ceram Zirconia (150,47MPa). Para a dureza Vickers, o material In-Ceram Zirconia (972,0VHN) mostrou-se superior em relação ao IPS-Empress 2 (488,33VHN). / Abstract: The aim of this study was to compare flexural strength, diametral tensile strength and hardness of infra-structure ceramic systems IPS-Empress 2/Ivoclar (litium dissilicate, heat-pressed) and In-Ceram Zirconia/Vita (aluminum and zirconium oxides, Slip casting). Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872), and 15 especimens for diametral test (6mm diameter; 3mm thick). The tests were done in a MTS 810 machine (Material Test System - USA), with load cell of 10kN and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 1.0kgf for 30 seconds. In flexural test, In-Ceram Zirconia (439.88MPa) showed greater strength than IPS-Empress 2 (226.13MPa). However, the IPS-Empress 2 (175.08MPa) showed greater diametral strength than In-Ceram Zirconia (150.47MPa). For hardness, the In-Ceram Zirconia (972.0VHN) showed greater than IPS-Empress 2 (488.33VHN). / Mestre

Page generated in 0.05 seconds