• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Variações da lipocalina urinária associada com gelatinase de neutrófilos humanos (NGALu) nos estágios precoces da injúria renal aguda pós-cinecoronariografia

Souza, Denis Fabiano de 26 July 2013 (has links)
The intravascular administration of iodine-based contrast media is a common cause of acute kidney injury (AKI). This study investigated whether changes in the urinary concentration of neutrophil gelatinase-associated lipocalin (uNGAL) before and after coronary angiography they are able to predict the development of AKI independently of previously established absolute cut-off values. A total of 125 outpatients undergoing elective coronary angiography were enrolled and divided into 2 subgroups: G1 (n = 103), patients with changes in their serum creatinine after coronary angiography of < 0.3 mg/dL, and G2 (n = 22), patients with changes in their serum creatinine after coronary angiography &#8805; 0.3 mg/dL. The primary study endpoint was AKI defined as AKI network stages 1. uNGAL was measured before coronary arteriography and 2 and 4 hours afterwards. To determine the sensitivity and specificity for the absolute and relative variations of uNGAL, a receiver operator characteristic (ROC) curve analysis was performed. Based on the ROC curve for the relative difference in uNGAL before and after coronary angiography, a 50% increase in the uNGAL value over baseline was 60% sensitive and 81% specific for AKI. The area under the curve for relative differences 2 hours after coronary angiography was 0.82. The percentage variations in the concentration of uNGAL detected the early stages of AKI regardless of the absolute cut-off established. / A administração intravascular dos meios de contraste à base de iodo é uma causa comum da injúria renal aguda. Este estudo investigou se mudanças na concentração da Lipocalina Urinária Associada com Gelatinase de Neutrófilos Humanos (NGALu), antes e após angiografia coronariana eletiva, são capazes de prever o desenvolvimento da injúria renal aguda, independentemente de pontos de corte previamente estabelecidos. Foram avaliados 125 pacientes ambulatoriais submetidos a cinecoronariografia eletiva. Os pacientes foram divididos em dois subgrupos; G1 (n=103), pacientes com alterações nos valores da creatinina sérica < 0,3 mg/dL e G2 (n=22), aqueles em que a creatinina sérica se elevou &#8805; 0,3 mg/dL. O endpoint primário dessa pesquisa foi a injúria renal aguda definida pelo acute kidney injury network estágio 1. Foram realizadas dosagens da Lipocalina urinária Associada com Gelatinase de Neutrófilos imediatamente antes, 2 e 4 horas após a cinecoronariografia. Para determinar a sensibilidade e especificidade das variações absolutas e relativas de NGALu utilizamos receiver operating characteristic (ROC). Com base na curva ROC para diferença relativa no NGALu antes e após a angiografia coronariana eletiva, um aumento de 50% no valor do NGALu após o procedimento, foi 60% sensível e 81% específico para detecção da injúria renal aguda. A área sob a curva para diferença relativa 2 horas após a cinecoronariografia foi 0,82. Variações percentuais na concentração de NGALu foram capazes de prever a injúria renal aguda 2 horas após a angiografia coronariana independentemente de pontos de corte estabelecido em valores absolutos. / Mestre em Ciências da Saúde
2

Validação do método imunonefelométrico para dosagem de cistatina C, como marcador de função renal / Validation of cystatin C measurement by particle-enhanced immunonephelometry as renal function marker

Neri, Letícia Aparecida Lopes 29 January 2008 (has links)
A cistatina C sérica tem sido apontada como um marcador de filtração glomerular. Neste trabalho realizamos a validação de um método específico e automatizado, a imunonefelometria, mensurando os níveis séricos de cistatina C através do nefelômetro da empresa Behring (BN II). O ensaio perfaz o intervalo de referência de 0.23-7.25 mg/L, até sete vezes acima dos limites considerados normais. A imprecisão intra e interensaio foram de 8,73% and 5,38% , respectively. A recuperação analítica de cistatina C após adição de controle foi entre 86,7 % e 98% (média 92,3%). A estabilidade da cistatina C a temperatura ambiente, sob refrigeração e sob congelamento foi testada. A perda mais significativa foi encontrada nas amostras armazenadas sob temperatura ambiente, onde foi perdido até 10% da concentração inicial. Nós encontramos CV de 14,79 % para sensibilidade analítica. Durante todo o processo nós comparamos os resultados com o controle de qualidade e obtivemos bons resultados. Depois destes testes, nós comparamos as correlações em 3 grupos de pacientes transplantados renais sob diferentes esquemas de imunossupressão (n=197) [azatioprina (n=36), micofenolato mofetil (n=131) ou sirolimus (n=30)], entre as equações de estimativa de filtração glomerular( Cockroft Gault, Nankivell e MDRD) e cistatina C sérica ou creatinina sérica. Nós concluimos que o ensaio nefelométrico cistatina C pode perfeitamente ser adequado à nossa rotina laboratorial e as correlações entre creatinina sérica e as diferentes equações de estimativa de filtração glomerular são melhores do que quando comparamos as mesmas à cistatina C nos 3 grupos independentemente da terapia imunossupressora utilizada. / Serum cystatin C has been suggested as a marker of glomerular filtration rate (GFR). We describe a validation of an automated and rapid particle-enhanced nephelometric immunoassay (PENIA) for measuring serum cystatin C on the Behring nephelometer (BN II). The assay covers the range 0.23-7.25 mg/L, up to seven times the upper limit of normal. The intra- and interassay imprecision are 8,73% and 5,38% , respectively. The analytical recovery by cystatin C addition between 86,7% and 98% (mean 92,3%). The estability of cistatyn C room temperature, refrigerator temperature and frozen temperature was tested. The higher lost was when we stored sample in a room temperature, when we can lost until 10% of initial concentration. We found CV of 14,79 % for analytical sensibility. During all the process we compare the results with a quality control and we obtained good results. After this validation, we have compared the correlation, in 3 different patients groups after renal transplant (n=197) were using different imunossupressors [azatioprine (n=36), micophenolic acid (n=131) or sirolimus (n=30), between glomerular filtration equations (Cockroft Gault, Nankivell and MDRD) and cystatin C or creatinine serum levels. We concluded cystatin C assay may be perfectly used in our laboratory and the correlation between serum creatinine and glomerular filtration equations are better then cystatin C at the same groups independent of imunosupressor therapy.
3

Validação do método imunonefelométrico para dosagem de cistatina C, como marcador de função renal / Validation of cystatin C measurement by particle-enhanced immunonephelometry as renal function marker

Letícia Aparecida Lopes Neri 29 January 2008 (has links)
A cistatina C sérica tem sido apontada como um marcador de filtração glomerular. Neste trabalho realizamos a validação de um método específico e automatizado, a imunonefelometria, mensurando os níveis séricos de cistatina C através do nefelômetro da empresa Behring (BN II). O ensaio perfaz o intervalo de referência de 0.23-7.25 mg/L, até sete vezes acima dos limites considerados normais. A imprecisão intra e interensaio foram de 8,73% and 5,38% , respectively. A recuperação analítica de cistatina C após adição de controle foi entre 86,7 % e 98% (média 92,3%). A estabilidade da cistatina C a temperatura ambiente, sob refrigeração e sob congelamento foi testada. A perda mais significativa foi encontrada nas amostras armazenadas sob temperatura ambiente, onde foi perdido até 10% da concentração inicial. Nós encontramos CV de 14,79 % para sensibilidade analítica. Durante todo o processo nós comparamos os resultados com o controle de qualidade e obtivemos bons resultados. Depois destes testes, nós comparamos as correlações em 3 grupos de pacientes transplantados renais sob diferentes esquemas de imunossupressão (n=197) [azatioprina (n=36), micofenolato mofetil (n=131) ou sirolimus (n=30)], entre as equações de estimativa de filtração glomerular( Cockroft Gault, Nankivell e MDRD) e cistatina C sérica ou creatinina sérica. Nós concluimos que o ensaio nefelométrico cistatina C pode perfeitamente ser adequado à nossa rotina laboratorial e as correlações entre creatinina sérica e as diferentes equações de estimativa de filtração glomerular são melhores do que quando comparamos as mesmas à cistatina C nos 3 grupos independentemente da terapia imunossupressora utilizada. / Serum cystatin C has been suggested as a marker of glomerular filtration rate (GFR). We describe a validation of an automated and rapid particle-enhanced nephelometric immunoassay (PENIA) for measuring serum cystatin C on the Behring nephelometer (BN II). The assay covers the range 0.23-7.25 mg/L, up to seven times the upper limit of normal. The intra- and interassay imprecision are 8,73% and 5,38% , respectively. The analytical recovery by cystatin C addition between 86,7% and 98% (mean 92,3%). The estability of cistatyn C room temperature, refrigerator temperature and frozen temperature was tested. The higher lost was when we stored sample in a room temperature, when we can lost until 10% of initial concentration. We found CV of 14,79 % for analytical sensibility. During all the process we compare the results with a quality control and we obtained good results. After this validation, we have compared the correlation, in 3 different patients groups after renal transplant (n=197) were using different imunossupressors [azatioprine (n=36), micophenolic acid (n=131) or sirolimus (n=30), between glomerular filtration equations (Cockroft Gault, Nankivell and MDRD) and cystatin C or creatinine serum levels. We concluded cystatin C assay may be perfectly used in our laboratory and the correlation between serum creatinine and glomerular filtration equations are better then cystatin C at the same groups independent of imunosupressor therapy.

Page generated in 0.0936 seconds