Spelling suggestions: "subject:"stestes dde fixação doo látex"" "subject:"stestes dde fixação doo mátex""
1 |
Detecção de rotavírus do grupo A em amostras fecaisadaptação do teste de aglutinação em látex para o emprego de anticorpos IgY anti-Rotavírus ALanzarini, Natália Maria January 2014 (has links)
Made available in DSpace on 2015-10-23T12:42:15Z (GMT). No. of bitstreams: 2
natalia_lanzarini_ioc_mest_2014.pdf: 2473569 bytes, checksum: 3ef3e9aeef4d618351a689e2550d62e8 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2015-04-14 / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Rio de Janeiro, RJ, Brasil / A infecção pelo rotavírus A (RVA) é responsável por cerca de 453.000 mortes anualmente e aproximadamente 40% das hospitalizações por diarreia em crianças menores de cinco anos em todo o mundo, sendo o principal causador de gastroenterite aguda nesse grupo populacional. O desenvolvimento de um método de diagnóstico rápido, barato, sensível e específico para a detecção de RVA é importante do ponto de vista epidemiológico porque permite identificar surtos no local de ocorrência. O uso da imunoglobulina Y (IgY), anticorpo purificado a partir da gema de ovo, vem crescendo nos últimos anos, devido às características vantajosas quando comparada com a imunoglobulina G (IgG), como a obtenção de anticorpos de forma não invasiva e a produção de anticorpos em grandes concentrações. Este trabalho objetivou a adaptação de um teste de diagnóstico através da substituição do anticorpo de captura IgG pela IgY específica para o antígeno de RVA (LATEXY-ROTA). Para isto 09 frangas poedeiras foram imunizadas com o RVA, os ovos foram coletados e a IgY purificada a partir da gema do ovo por polietileno glicol 6.000, seguida da purificação adicional por cromatografia de troca iônica
A IgY anti-RVA purificada foi ligada covalentemente à partículas de poliestireno e usada como insumo na adaptação de um teste de aglutinação em látex, sendo testada em um painel de amostras fecais sabidamente positivas e negativas previamente selecionadas pelo Centro Regional de Referência para Rotaviroses do Laboratório de Virologia Comparada e Ambiental (LVCA/IOC-FIOCRUZ). Foi obtida uma sensibilidade de 75% e uma especificidade de 87,5% quando o LATEXY-ROTA foi comparado com um teste imunoenzimático comercial disponível (padrão ouro). Quando comparado com dois testes comerciais de aglutinação em látex testados no painel de amostras utilizando a IgG, o LATEXY-ROTA obteve uma sensibilidade de 100% e especificidade de 88,24%. Baseado nos dados obtidos, sugerimos a viabilidade da substituição da IgG por IgY no ensaio de aglutinação pelo látex / The infection
by
rotavirus (RV
) is responsible for
approximately
453,000 de
aths
annually and approximately 40
% of hospitalizations
by
diarrhea in children under five
years worldwide
, being the major cause
of acute gastroent
eritis in this population
group
. The development of
a
rapid
method, inexpensive
, sensitive and specific for
rotavirus diagnosis is important from
the disease
because it allows
the identification
of
outbreaks
in the site of
occurrence
.
The
use of Immunoglobulin Y (IgY
) antibody
purified
from
egg yolk,
has been grow
n
in recent
years
, due to the advantageous
features compared
to
immunoglobulin G (IgG)
,
as
a noninvasive
recovery of
antibodies
and production
in
high concentrations
.
The aim of t
his
method
was
to
adapt
a diagnostic test by replacing the IgG capture antibody by specific IgY for
RVA
antigen
(LATEXY
-
ROTA).
For that, 09 laying hens were immunized with
RVA
, the
eggs were
collected and
IgY purified from egg yolk by polyethylene glycol 6
,000,
followed by purification
by ion exchange chromatography.
The
purified
anti
-
IgY
RVA
was covalently bound to polystyrene particles
, being tested in a p
anel
of
positive and
negative fecal samples previously
determined
by
the R
otavirus
Regional
Reference
Center
of
Compa
rative
and Environmental
Virology Laboratory (LVCA
/
IOC
-
FIOCRUZ
)
. A
sensitivity
of 75%
and specificity
of 85,7%
was observed
when
the
adapted test was
compared
to a
commercial available enzyme immunoassay (golden
standard).
When compared
to
two commercial l
atex agglutination tests
using the IgG
tested on the panel of samples
, the
LATEXY
-
ROTA
had a sensitivity
of 100% and
specificity of 88.2
%.
Based on the obtained data, we
suggest
the
feasibility of
replacing the IgG by IgY in the latex agglu
tination assay.
|
2 |
Detecção do vírus dengue pela técnica de aglutinação do látex modelo experimental.Luppino, Plinio Luis 04 June 2007 (has links)
Made available in DSpace on 2016-01-26T12:51:14Z (GMT). No. of bitstreams: 1
plinioluisluppino_tese.pdf: 1297185 bytes, checksum: 89ac3b7475f1bfd00a6808afd1ba661e (MD5)
Previous issue date: 2007-06-04 / Dengue is the arthropod-borne transmitted viral disease of highest worldwide prevalence in mortality and morbidity. The proportion is pandemic ranging 1.6 million of infected patients yearly. Clinical presentation associated to epidemiological factors such as dengue prevalence in the patient s origin have been the only mean for early diagnosis. Laboratorial diagnosis, the conclusive, requires several days when there is viral isolation. Serological methods depend on high level of specific antibodies, and molecular methods are not available for the majority of laboratories of diagnosis and routine. The purpose of this study was to develop an agglutination method using latex to detect dengue virus, using biological samples of mice infected with dengue 1 Mochizuki strain by intracerebral via, and anti-dengue 1 specific antibodies from immunized mice. According to the results, this method was feasible for the dengue viruses diagnosis in positive samples of experimental animals. It provides further approaches for rapid detection of dengue in susceptible populations during the first days of the disease. / A dengue é a doença viral, transmitida por artrópode, de maior prevalência mundial em morbidade e mortalidade. Alcança proporções pandêmicas, estimando-se em 1,6 milhões de doentes anualmente. Manifestações clínicas características, associadas a fatores epidemiológicos, como prevalência da dengue na região de origem do paciente, têm sido os únicos instrumentos de diagnóstico precoce. O diagnóstico laboratorial, que é definitivo, demanda vários dias, quando realizado o isolamento viral. Métodos sorológicos dependem de níveis elevados de anticorpos específicos e os métodos moleculares não estão disponíveis para a maioria dos laboratórios de diagnóstico e rotina. Este estudo teve como objetivo desenvolver método de aglutinação do látex para a detecção do vírus dengue, utilizando amostras biológicas de camundongos infectados por via intracerebral com dengue 1, cepa Mochizuki e anticorpos específicos anti-dengue 1, obtidos de camundongos imunizados. Os resultados obtidos demonstraram a viabilidade deste método para diagnóstico do vírus Dengue em amostras positivas de animais de experimentação, abrindo novas perspectivas para o diagnóstico precoce da dengue na população susceptível, durante os primeiros dias de sintomas.
|
Page generated in 0.1006 seconds