• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 307
  • 106
  • 34
  • 21
  • 19
  • 10
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 581
  • 581
  • 315
  • 294
  • 125
  • 88
  • 78
  • 76
  • 69
  • 68
  • 64
  • 63
  • 59
  • 58
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Avaliação de materiais alternativos como coberturas em instalações para produção animal visando o conforto térmico / Evaluation of alternative materials as coverings in installations for animal production aiming at the thermal comfort

Cardoso, Alaércio de Sousa 27 August 2010 (has links)
Made available in DSpace on 2015-03-26T13:23:32Z (GMT). No. of bitstreams: 1 texto completo.pdf: 832590 bytes, checksum: 366f1e8483b746bfb918ff8857b8e87b (MD5) Previous issue date: 2010-08-27 / Brazil, to remain competitive in agribusiness, the challenge is to continue production with low cost technologies in facilities with favorable environment conditions. In general, coverage due to represent much of the building, is the factor that has great influence on the environmental conditions for livestock. The efficiency is associated with the type of tiles material they are made, characterized by isolation, damping and thermal delay and associated with the superficial nature, characterized by radiant absorptivity and emissivity. Using the theory of similarity for the definition of 1:12 scale models, and thermal environmental indices, the objective of this research was to evaluate the conditions inside poultry or cattle sheds made with five types of alternative material roofs, namely: Tetra Pak, toothpaste tubes, Onduline with vegetable fiber and bitumen, Reciplac aluminized on the top and white on the bottom, Reciplac aluminized on the top and neutral on the bottom, compared with the tiling of clay, with and without the presence of an insulating undercoverage, under hot conditions. Considering the Black Globe Temperature and Humidity Index, the Radiant Thermal Load and Thermal Effectiveness enabled by coverage, in the birds and cattle level, it was found that in general there was similarity between the results, but with differences was amplified when the curtains were closed, and that during hot days, the best conditions were associated with coverage of clay. The worst results were associated with the coverage Onduline - vegetable fiber and asphalt - with and without under-coverage, Tetra Pak coverage - no under-coverage, Reciplac aluminized on the upper side and white on the bottom - with and without undercoverage, and Reciplac aluminized above and neutral below - with undercoverage. The use of an insulating undercoverage was unable to promote improvement in environmental thermal conditions, unless associated with the tiles of worse performance. It was estimated reduction in the initial cost of the roof, in comparison to the coverage of clay, at 47, 7% for Reciplac aluminized coated on the upper side and white on bottom, 45, 5% for Reciplac aluminized on the upper face and neutral at the bottom and 41, 2% for the roof made of Tetra Pak tiles. / O Brasil, para que continue competitivo no agronegócio, persiste o desafio da produção com tecnologias de baixo custo, em instalações com condições ambientais favoráveis. De forma geral, a cobertura por representar grande parte da envolvente, é o fator que tem grande influência sobre as condições do ambiente de galpões para a criação animal, sendo sua eficiência associada ao tipo do material constituinte das telhas, caracterizado pelo isolamento, amortecimento e retardo térmico, e associado à natureza superficial, caracterizado pela absortividade e emissividade radiante. Com a utilização da teoria de similitude, para definição de modelos reduzidos na escala 1:12, e de índices térmicos ambientais, o objetivo deste trabalho foi avaliar as condições no interior de galpões de avicultura ou bovinocultura, confeccionados com cinco tipos de coberturas de materiais alternativos, ou seja: embalagens Tetra Pak, tubos de pastas de dentes, Onduline com fibra vegetal e betume, Reciplac aluminizada na face superior e branca na inferior e Reciplac aluminizada na face superior e neutra na inferior, em comparação com a cobertura de telhas de barro, com e sem a presença de manta isolante subcobertura, em condições de calor. Considerando o Índice de Temperatura de Globo Negro e Umidade, a Carga Térmica Radiante e a Efetividade Térmica propiciados pelas coberturas, ao nível das aves e dos bovinos, verificou-se no geral que ocorreu semelhança entre resultados, porém com diferenças amplificadas quando as cortinas estavam fechadas, e que, no período quente do dia, as melhores condições estiveram associados à cobertura de barro. Os piores resultados estiveram associados com as coberturas Onduline fibra vegetal e betume - com e sem subcobertura, cobertura reciclada de Tetra Pak - sem subcobertura, cobertura Reciplac aluminizada na face superior e branca na inferior - com e sem subcobertura, e cobertura Reciplac aluminizada em cima e neutra por baixo - com subcobertura. O uso da manta isolante subcobertura não foi capaz de promover melhoria nas condições térmicas ambientais, a não ser quando associada a coberturas de pior desempenho. Estimou-se redução nos custos iniciais do telhado em comparação ao de cobertura de barro, em 47, 7% para o com cobertura Reciplac aluminizada na face superior e branca na inferior, 45, 5% para o com cobertura Reciplac aluminizada na face superior e neutra na inferior e 41, 2% para o com cobertura de material reciclado Tetra Pak.
132

Análise do uso de estratégias para a melhoria de eficiência energética e do conforto térmico em edificações com sistemas de automação predial-residencial

Vizzotto, Marcos Rodrigues January 2015 (has links)
O presente trabalho apresenta uma proposta para melhoria da eficiência energética e do conforto térmico em edificações com sistemas de automação predial-residencial. O desenvolvimento da proposta do trabalho foi dividido em três etapas: na primeira etapa foi realizada uma análise inicial do desempenho de uma sala de aula automatizada, com relação ao consumo de energia elétrica do sistema de climatização e o conforto térmico dos usuários, em 4 cenários típicos de uso da sala. Esta análise indicou claras possibilidades de melhorias no sistema de automação, de forma a aumentar o conforto térmico e reduzir-se o consumo de energia. Numa segunda etapa da proposta foi aplicada uma estratégia de alteração dos horários de funcionamento do sistema de climatização com o objetivo de melhorar o conforto térmico dos usuários. Para validação das estratégias propostas foi desenvolvido, utilizando-se o software EnergyPlus, um modelo computacional para simulação da variação de temperatura da sala. Com a análise comparativa de simulações observou-se que alterando o horário de funcionamento do sistema de climatização foi possível manter a sala 100% do tempo na faixa de conforto térmico durante as aulas, porém com um aumento no consumo de energia. Em função disto, numa terceira etapa da proposta foi aplicada uma estratégia para ajustar o valor de setpoint de resfriamento do sistema de climatização integrado ao sistema de automação da sala com o objetivo de melhorar a eficiência energética. O algoritmo foi inicialmente desenvolvido com o software Matlab e foi co-simulado com o modelo computacional utilizando a ferramenta MLE+. Com a análise comparativa de simulações e co-simulações observou-se que houve uma redução no consumo de energia de cerca de17% na sala numa comparação com os cenários validados na primeira etapa. Os conceitos desenvolvidos foram então aplicados no projeto de uma nova edificação, no qual uma redução no consumo de energia em torno de 6%. / The present paper presents a proposal of improvement of energy efficiency and thermal comfort in buildings with home and building automation. The development of the proposal of the paper was divided into three stages: At the first stage it was realized an initial analysis of the performance of an automated room in relation to the consumption of electrical energy by the air conditioning system and the thermal comfort of the users in four typical scenarios of the room use. This analysis indicated clear possibilities of improvement on the automation system in terms of improving thermal comfort and decreasing energy consumption. At the second stage of the proposal it was applied a strategy of alteration of the operation times of the air conditioning system with the objective of improving the thermal comfort of the users. To validate the strategies proposed it was developed, using the EnergyPlus software, a computational model to simulate the variations in temperature in the room. With the comparative analysis of the simulations it was observed that altering the operation times of the air conditioning system it was possible to maintain the room in the thermal comfort zone 100% of the time, however, with an increase in energy consumption. Therefore, at the third stage of the proposal it was applied a strategy to adjust the cooling set point of the air conditioning system integrated to the automation system with the objective of improving energy efficiency. The algorithm was developed initially with the Matlab software and it was co-simulated with the computational model utilizing the MLE+ tool. With the comparative analysis of simulations and co-simulations it was observed that there was a reduction of around 17% in the consumption of energy in the room compared with the scenarios validated at the first stage. The concepts developed were then applied on the project of a new building, in which the reduction of energy consumption was around 6%.
133

Modelling the thermal comfort performance of tents used in humanitarian relief

Poschl, Ruth A. January 2017 (has links)
Globally, billions of people live in temporary shelters due to poverty, and every year millions of refugees and disaster affected individuals are forced to live in temporary shelters such as Standardised Emergency Relief Tents (SERTs). The Office of the United Nations High Commissioner for Refugees (UNHCR) has spent millions of US dollars annually on tents, blankets and mattresses. The tents used are designed as temporary accommodation; in reality they sometimes become homes for a number of years when the return to permanent shelter is slow or unaffordable. While the SERT aims to adhere to humanitarian standards for basic shelter provision, this type of construction is ultimately designed to be quick to deploy, using lightweight and cost effective materials. Consequently, SERTs have been known to provide an extremely thermally uncomfortable place to live in different climates, requiring stove heating in cold climates and being impractical to keep cool in hot climates. Little research has been done to determine whether this situation could be improved. The thermal comfort performance of a real SERT in a known UK climate was investigated, to explore the science behind the experience of real users. Measurements were made in the SERT over a 6 month period and the observations quantitatively analysed in order to characterise and explain the tent s response to a range of outdoor conditions. The predicted thermal comfort in the SERT was calculated using a variety of suitable metrics. The data collected in a UK climate was used to develop and validate computational models of the SERT, which have applications in any world climate. Based on quantitative analysis of the SERT models performances in cold, temperate and hot climates, conclusions were drawn regarding the suitability of the SERT for use in each climate. The computational models of the SERT were modified in geometry and material, with the aim of improving the predicted thermal comfort in the SERT in hot and cold climates. The effectiveness of these design changes was analysed, and recommendations for improvements to the SERT were made. These recommendations could be used by SERT manufacturers and key humanitarian organisations in order to facilitate design modifications.
134

The energy and thermal performance of UK modular residential buildings

Quigley, Ella S. January 2017 (has links)
This research concerns the in-use performance of light-gauge steel modular construction used for residential purposes. The aim was to investigate ways to reduce the in-use energy consumption of new buildings, while ensuring thermal comfort. Data were collected from two case study buildings in the UK, one in Loughborough and the other in London, using a variety of methods including building measurement, building monitoring, inspections, and a detailed review of the construction documentation. The case study buildings were monitored using EnOcean enabled wireless sensor networks and standalone temperature sensors. Monitoring data included electricity consumption in individual rooms, often by end use, space heating use, internal temperature and relative humidity, and external temperature. Building measurements included blower door tests to measure fabric air leakage rates, infrared thermal imaging to identify fabric defects and weaknesses, and ventilation system flowrate measurements. Inspections and the review of documentation allowed problems with design, manufacture and construction to be identified. A particular concern for thermally lightweight construction is the risk of overheating, therefore overheating analyses were undertaken. The research identified weaknesses in the design, construction and operation of the case study buildings resulting in increased energy use and poor thermal comfort, particularly overheating. The modular construction studied requires specific design changes to improve the fabric and building services, in order to reduce energy use. There are also specific recommendations for quality control on site to ensure critical stages are correctly completed, such as installing rigid insulation. There are also more general recommendations for how a company operates because this can influence performance; there ought to be greater attention to holistic design and greater collaboration with suppliers and contractors to determine robust solutions. Overheating was a problem in the London case study, and more research is required to understand the scale of the problem. Avoidance of overheating must be a focus in the design of new buildings. The findings suggest that once the problems with the design and quality control on site are rectified, offsite modular construction can be used to consistently and reliably provide low energy homes.
135

The Built Environment & Transit User Experience at Semi-Outdoor Emerald Express Bus Rapid Transit Stations

Rasool, Sundas 01 May 2017 (has links)
This research studied the relationship between transit users’ travel experience and the built environment bus rapid transit (BRT) stations. The study recorded attributes of the built environment and user perceptions at eight Emerald Express stations between Eugene and Springfield, Oregon as case studies. It found that of the attributes studied, transit users’ satisfactions of pedestrian accessibility had strong correlations with their preference of using EmX over a car. It also found that users perceived stations in built environments with spare street shading and commercial land-uses as less safe, and were also less satisfied with weather protection at stations with low street shading. The study found Universal Thermal Climate Index (UTCI) and Predicted Mean Votes (PMV) to mostly identify the same categories of thermal stress. The study developed a rating system to evaluate station performance based on quantitative attributes and suggests short and long term improvements to improve semi-outdoor bus stations.
136

A influência dos parques verdes no conforto térmico urbano : estudo de caso em Porto Alegre - RS / The influence of green parks in urban thermal comfort : case study in Porto Alegre - RS

Zorzi, Lizia de Moraes de January 2016 (has links)
O padrão de desenvolvimento das cidades brasileiras nas últimas décadas, com acelerada urbanização, tem mostrado resultados prejudiciais sobre a forma das cidades, a qualidade de vida nelas e o consumo dos recursos naturais. Para promover a sustentabilidade no planejamento urbano é importante adequar o ambiente construído ao clima local, permitindo ao homem viver em conforto e reduzir o consumo dos recursos naturais. Uma das maneiras apontadas para melhorar a qualidade das cidades e o conforto térmico nelas é através da criação de parques verdes. Este trabalho tem por objetivo analisar a influência dos parques verdes no conforto térmico urbano, através de estudo de caso em Porto Alegre/RS. A pesquisa parte da revisão bibliográfica, para explicar como as áreas verdes podem contribuir para o conforto térmico urbano. Para o estudo de caso foi analisada a influência dos parques Farroupilha, Moinhos de Vento e Germânia nos seus entornos, através de medições in loco de temperatura e umidade do ar, principais variáveis de conforto térmico, e de análises de dados de sensoriamento remoto. Utilizando índices que consideram apenas estas duas variáveis, um com base da carta de Givoni e outro no cálculo da Temperatura Efetiva, não foi possível observar correlação entre o conforto térmico e a presença e proximidade dos parques. Entretanto, analisando as variáveis, é possível observar que os parques aumentaram entre 3,54 e 13,94% a umidade relativa do ar e reduziram a temperatura do ar em até 2,3°C. As análises de sensoriamento remoto vão ao encontro destes resultados, chegando 8,6°C as diferenças de temperaturas de superfície obtidas no interior e no entorno dos parques. Os três parques estudados influenciaram nas variáveis de conforto nos seus entornos, sendo o efeito de oásis mais significativo nos parques maiores e com áreas mais arborizadas e superfícies de água. Assim sendo, até mesmo os parques menores contribuem para a redução das ilhas de calor urbano, evitando que as temperaturas dos centros das cidades aumentem ainda mais. / The pattern of development of Brazilian cities in recent decades, with rapid urbanization, have shown harmful results on the morphology of the cities, the quality of life in them and the consumption of natural resources. To promote sustainability in urban planning it is important to adapt the built environment to the local climate, allowing to live in comfort and to reduce the consumption of natural resources. One of the ways aimed at improving the quality of cities and the thermal comfort in them is by creating green parks. This work aims to analyze the influence of green parks in the urban thermal comfort a case study in Porto Alegre / RS. The study of the literature review can explain how green areas can contribute to the urban thermal comfort. For the case study we analyzed the influence of three parks (Farroupilha, Moinhos de Vento and Germânia) with their surroundings by measurements, in situ, of temperature and humidity, the main variables of thermal comfort, and remote sensing data analysis. Using indexes treating only these two variables, one based on the chart of Givoni and the other in the calculation of Effective Temperature, was not observed correlation between thermal comfort and the presence and proximity of the parks. However, analyzing the variables we can observe that the parks have increased of relative air humidity between 3.54 and 13.94% and reduced air temperature of 2.32°C. Remote sensing analysis are in agreement with these results, reaching 8.56°C differences in surface temperatures obtained inside and around the parks. The three parks studied influenced variables the comfort of in their surroundings, with the oasis effect very significant on the largest parks and more wooded areas and water surfaces. Even the smallest parks contribute to the reduction of urban heat islands, preventing temperatures from urban centers to increase further.
137

Parâmetros fisiológicos em bovinos leiteiros submetidos ao estresse térmico / Physiological parameters in dairy cattle applied thermal stress

Dalcin, Vanessa Calderaro January 2013 (has links)
A seleção para produção de leite vem aumentando a suscetibilidade de vacas leiteiras ao estresse térmico, principalmente em raças europeias em regiões tropicais e sub-tropicais. Cerca de 95% do rebanho leiteiro no Brasil é composto por animais mestiços. O objetivo deste trabalho, conduzido no campo experimental José Henrique Bruschi da Embrapa Gado de Leite, em Coronel Pacheco – MG, durante o mês de março de 2013, foi investigar alterações nos parâmetros fisiológicos de vacas leiteiras que identifiquem com maior fidedignidade o estresse calórico. Foram realizadas coletas de sangue para análise do hematócrito (Ht), contagem de eritrócitos (ERI) e contagem de hemoglobina (HEMO), além do registro da temperatura retal (TR), da frequência cardíaca (FC), da frequência respiratória (FR), do escore de ofegação (EO) em 38 fêmeas bovinas em lactação, divididas conforme o grupo genético em ½, ¾ e puras, durante seis dias nos turnos da manhã e da tarde. Os dados foram submetidos à análise da variância considerando os efeitos de grupo genético, dias, turnos e suas interações, com medidas repetidas no tempo e regressão “broken-line”. Houve efeito significativo para a interação grupo genético*dia*turno para TR, FC, FR e EO. Os valores de TR, FC, FR e EO do grupo de vacas puras HO foram maiores em relação ao grupo ¾ e esse em relação ao grupo ½. No grupo de vacas puras, as variáveis fisiológicas aumentaram linearmente com o Índice de Temperatura e Umidade (ITU), sem apresentar inflexão. O ponto de inflexão das curvas de variáveis fisiológicas ocorreu num valor de ITU mais alto para o grupo ½ em relação aos demais. Os valores de Ht e HEMO foram distintos entre os grupos genéticos, mas não variaram com o ITU, mostrando que o estresse provocado não foi suficiente para alterar os parâmetros hematológicos medidos. A média de ITU durante o turno da manhã foi de 74, quando 70, 43 e 13% das vacas puras, ¾ e ½, respectivamente, se apresentavam com a FR acima dos padrões de referência. A FR foi o melhor indicativo do estresse térmico e seu valor crítico foi de 140mov/min para as vacas Girolando e 168 mov/min para a raça Holandesa. Vacas da raça Holandesa são mais sensíveis ao estresse térmico do que cruzas Holandês-Zebuíno. / Selection for milk production has increased the susceptibility of dairy cows to heat stress, especially in European breeds reared in tropical and sub - tropical conditions. About 95% of dairy cattle in Brazil are crossbred animals. This study, conducted in the Embrapa Dairy Cattle José Henrique Bruschi experimental station, Coronel Pacheco - MG, was used to investigate changes in the physiological parameters of dairy cows to identify heat stress with greater reliability. Blood samples were collected for analysis of hematocrit (Ht), erythrocyte count (ERI) and hemoglobin count (HEMO), in addition to recording the rectal temperature (RT), heart rate (HR), respiratory rate (RR), panting score (PS) in 38 lactating cows. These varied according to genetic group (½, ¾ and pure bred Holstein (HO)), anda data was collected for six days in the morning and afternoon. Data were subjected to analysis of variance considering the effects of genetic group, days, time of day and their interactions with repeated measures and broken-line regression. Significant effects were found for the interaction between genetic group*day*time of day for RT, HR, RR and PS. These values were higher for pure HO cows were higher than in ¾ and ½ groups. In the HO group, physiological variables increased linearly with the Temperature Humidity Index, without presenting inflection in the regression. The inflection point occurred at a higher ITU highest value for the ½ group compared with the other groups. Ht and HEMO were different among genetic groups and did not vary with the ITU, showing that stress caused was not sufficient to alter the hematological parameters measured. The average THI during the morning shift was 74, when 70, 43 and 13 % of pure HO, ¾ and ½, respectively, presented FR above the standard. The FR was the best indicator of heat stress and its critical value was 140mov/min for Gir cows and 168 mov / min for Holsteins. Holstein cows are more sensitive to heat stress than crossbred Holstein- Zebu.
138

Influência do sombreamento natural de duas espécies arbóreas na temperatura de edificações

Ayres, Mário Carlos Rodrigues [UNESP] 10 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-10Bitstream added on 2014-06-13T20:22:26Z : No. of bitstreams: 1 ayres_mcr_dr_botfca.pdf: 1999593 bytes, checksum: 4eed8f4e59e415e484ad679e07a8b14b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / O objetivo desta pesquisa foi o estudo de diferentes espécies arbóreas quanto ao sombreamento e seus efeitos na temperatura de um ambiente construído, a partir de medições de temperaturas de globo e do ar, umidade relativa e velocidade do vento. A pesquisa foi desenvolvida na Empresa Brasileira de Pesquisa Agropecuária/Embrapa Agropecuária Oeste, no município de Dourados-MS. Foram analisados o sombreamento de duas espécies arbóreas, a Sibipiruna (Caelsalpinia peltophoroides) e o Flamboyant (Delonix regia), quanto à atenuação da temperatura em ambientes internos, proporcionada pela sombra de cada uma das espécies, em edificações abertas. Os dados foram coletados em dois módulos de edificação de madeira e cobertos com telhas de fibro-cimento, localizados ao sol e à sombra das espécies analisadas. Nestes módulos foram obtidos dados de temperatura do ar, umidade relativa e temperatura de globo negro. Os dados de velocidade do vento foram obtidos na Estação Meteorológica da Embrapa Agropecuária Oeste. Com os dados obtidos foram calculadas as porcentagens de atenuação da temperatura para cada um dos módulos e as variações relativas das temperaturas do ar e de globo negro. Avaliando-se os resultados obtidos, observou-se que o sombreamento natural produzido pela Sibipiruna proporcionou à sombra uma atenuação na temperatura de globo negro de 2,82ºC e na temperatura do ar de 0,96ºC menor em relação aos dados obtidos ao sol e, uma porcentagem de atenuação de 8.34 % e 3,16% respectivamente. Analisando-se os resultados, observou-se que o sombreamento natural do Flamboyant produziu à sombra uma atenuação na temperatura de globo negro de 3,96ºC e na temperatura do ar de 1,26ºC menor em relação aos dados obtidos ao sol e, uma porcentagem de atenuação de 9.62% e 3,46% respectivamente... / The objective of this research was to study different arboreal species in relation to the shading and its effects on temperature of a constructed environment, from measurements of temperatures of the globe and of the air, relative humidity and speed of the wind. The research was developed at Brazilian company of farming research/Embrapa Agropecuária Oeste, on Dourados City, Mato Grosso do Sul State. The shading of two arboreal species, Sibipiruna tree (Caelsalpinia peltophoroides) and Flamboyant tree (Delonix regia) had been analyzed in relation to the attenuation of the temperature in internal environments, provided for the shade of each one of the species, in opened constructions. The data had been collected in two modules of wooden construction and covered with asbestos-cement roofing tiles, located under the sun and in the shade of the analyzed species. In these modules, they had been gotten data of temperature of the air, relative humidity and temperature of the black globe. The data of speed of the wind had been gotten at Meteorological Station from Embrapa Agropecuária Oeste. With the gotten data, the percentages of attenuation of the temperature for each one of the modules and the relative variations of the temperatures of the air and of the black globe had been calculated. Evaluating the results gotten, it is observed that the natural shading produced by Sibipiruna tree provided to the shade an attenuation on temperature of the black globe of 2.82ºC and on temperature of the air of 0.96ºC lesser than the data gotten under the sun, and a percentage of attenuation of 8.34 % and 3.16%, respectively. Analyzing the results, it is observed that the natural shading of Flamboyant tree produced to the shade an attenuation on temperature of the black globe of 3.96ºC and...(Complete abstract, click electronic access below)
139

Análise do desempenho térmico de edificações escolares : estudo de caso do Centro de Educação Profissional do Vale do Caí e da Escola de Ensino Fundamental Frei Pacífico

Tubelo, Renata Camboim Salatino January 2011 (has links)
A pesquisa analisa o desempenho térmico de duas edificações escolares distintas, o Centro de Educação Profissional do Vale do Caí e a Escola de Ensino Fundamental Frei Pacífico, localizados em municipalidades também distintas e compostos por tipologia arquitetônica e orientação solar similares. Método: Os dois casos estudados tiveram o seu desempenho analisado pelo método de medição in loco, com coleta horária das variáveis de temperatura e umidade relativa do ar, fazendo uso de data loggers. A amostra foi composta por uma sala de aula, em cada ambiente de ensino. Objetivos: Foram objetivos desta pesquisa: caracterizar os estudos de caso; calcular as propriedades térmicas dos fechamentos; apontar distinções no procedimento de coleta de dados; analisar o desempenho térmico das salas estudadas, considerando o período de medições e o período de ocupação; e comparar dados climáticos das municipalidades com os dados climáticos de Porto Alegre. As análises foram estruturadas por estações do ano, com análise de temperatura (incluindo atraso e amortecimento térmico) e umidade relativa do ar. Auxiliaram nas análises de dados, a metodologia de análise de graus-hora e a carta bioclimática proposta por Givoni. Foram realizadas análises considerando o período de medições e o período de ocupação das escolas. Resultados: Os resultados apontaram um desempenho mais satisfatório para o Centro de Educação Profissional do Vale do Caí, o que pode ser atribuído à inércia térmica e às propriedades térmicas dos fechamentos deste edifício, mesmo tendo apresentado oscilações maiores de temperatura e umidade relativa. A análise dos dados climáticos das municipalidades permitiu identificar algumas similaridades com os do município de Porto Alegre, embora a proximidade deste com massas d’água tenham demonstrado interferência considerável na amplitude térmica e na umidade relativa do ar. / The research examines the thermal performance of two different school buildings, Vale do Caí Professional Education Center and Frei Pacífico Elementary School, located in different municipalities and also composed of similar architectural style and solar orientation. Method: The two cases studied had their performance evaluated by the in situ measurement method, with hourly collected hourly rate of the variables of temperature and relative humidity, using data loggers. The sample consisted of one classroom in each teaching environment. Objectives: The objectives of this research: were to characterize the case studies; to calculate the thermal properties of the elements; to point out distinctions in the procedure of collecting data; to analyze the thermal performance of the classrooms studied, considering the measurement period and the period of occupation; and comparing climatic data of municipalities to the climate data from Porto Alegre. The analysis was structured by seasons, with analysis of temperature (including thermal delay and thermal damping) and relative humidity, to help the data analysis methodology degree-hours and bioclimatic chart proposed by Givoni. There were analyses considering the measurement period and the period of school occupation. Results: The results showed a more satisfactory performance for Vale do Caí Professional Education Center, which can be attributed to thermal inertia and thermal properties of the closures of the building, though it had the highest swings in temperature and relative humidity. The analysis of climate data of the municipalities identified some similarities with that of the city of Porto Alegre, although the proximity of masses of water to the later, demonstrated considerable interference in the temperature and relative humidity ranges.
140

Avaliação da percepção da sensação térmica em uma sala de controle

Grandi, Mariele Stefani January 2006 (has links)
Este trabalho aborda a avaliação da percepção do conforto térmico em uma sala de controle, tendo como objetivo identificar quais os fatores que influenciam na sensação térmica dos operadores e se esta sensação difere estatisticamente entre os quatro turnos de trabalho. Foram medidas as variáveis ambientais (temperatura do ar, temperatura média radiante, umidade do ar e velocidade do ar), levantadas as variáveis pessoais (vestimenta e taxa metabólica) e aplicados questionários para coletar as sensações térmicas dos operadores a cada 1 hora. A taxa metabólica foi estimada em função da atividade, conforme os valores tabelados pela ASHRAE (2001), mas tal estimação pode apresentar imprecisões devido às diferenças individuais e às condições fisiológicas do ser humano, que são influenciadas pelo ritmo circadiano. O isolamento térmico médio das vestimentas foi de 0,5 a 0,8clo, sendo que os valores mais elevados ocorreram no turno da madrugada. Devido ao controle ambiental térmico da sala, a temperatura média do ar ao longo do dia permaneceu dentro de limites muito próximos. A sensação térmica predominantemente relatada pelos operadores, foi neutra, isto é, nem frio nem calor. Apenas em alguns períodos, principalmente no turno da madrugada, foi relatado desconforto devido ao frio. Não houve diferença significativa entre os resultados de conforto para os diferentes turnos de trabalho, mas o assunto merece estudos mais aprofundados. Os valores de PMV apresentaram baixa correlação estatística com as sensações relatadas pelos operadores, provavelmente em função dos valores da taxa metabólica e do isolamento térmico das vestimentas serem tabelados e não se ajustarem ao ambiente de trabalho. Devido a esta baixa correlação, a Anova não paramétrica de Kruskal-Wallis foi utilizada permitindo identificar que a temperatura do ar, a temperatura média radiante, a umidade do ar e a vestimenta utilizada influenciaram a sensação térmica dos operadores. Tendo em vista que o PMV não predisse a sensação térmica dos usuários, conclui-se que ele não é um bom parâmetro para uso em projetos de ambiente construído. / This present work approachs the evaluation of thermal comfort perception inside a control room, having the specific goal to identify which factors are important to the worker’s thermal sensation and if this sensation differs statistically among the four shifts work. Each environmental parameter (air temperature, mean radiant temperature, relative humidity and air velocity) were measured. The personal variables (clothing insulation and metabolic rate) were evaluated and questionnaires were applied to collect worker’s thermal sensation each hour. The metabolic rate was estimated through the activity, according to the ASHRAE table (2001). This estimative might not be precise due to individual differences and to physiological conditions of the human being, which are influenced by the circadian rhythm. The clothing insulation was 0,5 to 0,8 clo, and the highest values occurred in the early hours of the morning. Owing to the environmental control of the room, the mean air temperature through the day did not have significant changes. The thermal sensation predominantly reported by the workers was neutral, that is, neither cold nor warm. Only in a few periods, especially in the early hours of the morning, was related discomfort because of the cold. There is not a significative difference among the comfort results for the different shifts work, but the topic deserves deeper studies. The PMV values no small statistic correlation with the sensations related by the workers, probably due to the values of the metabolic rate and to the clothing insulation be tabled and were not to adjustable to the work environment. As a result of this weak correlation, the Kruskal-Wallis non parametric Anova was used to identify that air temperature, mean radiant temperature, air relative humidity and clothing insulation influenced the worker’s thermal sensation. Considering that the PMV did not predict the worker’s thermal sensation, the data suggest that the PMV is not a good parameter to be used in projects of buildings.

Page generated in 0.0425 seconds