• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 85
  • 23
  • 9
  • 1
  • 1
  • 1
  • Tagged with
  • 119
  • 119
  • 62
  • 61
  • 33
  • 33
  • 28
  • 27
  • 24
  • 21
  • 21
  • 20
  • 17
  • 17
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Thermométries ultrasonore et infrarouge pour le contrôle de la protection myocardique / Ultrasonic and infrared thermometries for the control of myocardial protection

Engrand, Céline H. 30 November 2016 (has links)
Le succès de la chirurgie cardiaque dépend essentiellement de la préservation des tissus durant l'opération. Afin d'optimiser cette dernière, une protection myocardique est appliquée à travers la perfusion d'une cardioplégie hypothermique lui permettant de tolérer l'ischémie provoquée par l'absence de vascularisation. Malgré ces progrès techniques et les connaissances accumulées, la chirurgie cardiaque reste une chirurgie à risque dont les complications sont parfois de nature inconnue. Il n'existe pourtant pas de suivi opérationnel de la protection myocardique et les seules indications disponibles pour le chirurgien sont l'arrêt contractile du cœur en début de cardioplégie ou l'apparition de fibrillations cardiaques dénonçant une inefficacité à long terme de la cardioplégie. Parmi les paramètres de mesure pouvant contribuer à la surveillance du myocarde sous cardioplégie, le suivi du changement de température induit par celle-ci pourrait devenir un indicateur pertinent. L'objectif de ce travail de thèse est donc de mettre en place un dispositif de suivi thermique du cœur permettant d'évaluer concrètement la diffusion et l'efficacité de perfusion cardioplégique durant la chirurgie cardiovasculaire.Parmi les méthodes de suivi thermique non invasives implantables en salle d'opération, la thermométrie par ultrasons (TUS) et la thermographie par infrarouges (TIR) ont retenu notre attention. Dans un premier temps, une méthode directe de thermométrie par ultrasons basée sur le principe "d'écho tracking" est expérimentée via un capteur ultrasonore $2,25 MHz mono-élément sur une gamme de température de 10 à 30°C. Cependant la caractérisation du muscle cardiaque par ultrasons et les expérimentations menées en laboratoire ont mis en avant la complexité du milieu nécessitant une calibration préalable, difficile à mettre en place en conditions opératoires. La technique présente tout de même une précision de mesure satisfaisante pour une variation de température inférieure à 10°C. Un modèle d'ajustement est alors proposé afin d'identifier la tendance de réchauffement interne du cœur à partir de la température de surface mesurable via une caméra thermique à infrarouge et par l'estimation volumique du milieu par ultrasons. Le modèle est validé dans un premier temps par simulation par éléments finis et dans un second temps durant des expérimentations sur fantômes et cœur in-vitro.Au final, le dispositif multi-physique TIR et TUS est expérimenté sur modèle in-vivo lors d'opérations, durant lesquelles des sessions de refroidissement par cardioplégie hypothermique sont effectuées. L'étude se conclut sur des premiers résultats de suivi thermique satisfaisants où les températures surfaciques acquises par TIR et l'estimation de l'épaisseur des parois ventriculaires par ultrasons permettent d'obtenir efficacement la tendance de réchauffement du myocarde. Le dispositif multi-physique a également démontré la possibilité d'appliquer une calibration directe de la thermométrie ultrasonore. Cette étude de faisabilité a démontré la possibilité d'un monitoring thermique du cœur de manière non invasive et applicable en temps réel. Ce dispositif pourrait être, après adaptation spécifique, implémenté durant les interventions cardio-vasculaire et fournir un indicateur précieux aux chirurgiens quant à l'efficacité de la protection myocardique. / The success of cardiac surgery essentially depends on tissue preservation. To optimize this latter, a myocardial protection is applied thanks to a hypothermic cardioplegia that confers a marked protective effect to the heart under ischemia. Despite these technical developments, cardiac surgery still presents risks and complications are sometimes of an unknown nature. However, no operational real-time monitoring of myocardial tissue exists. Among the metrics that could be analyzed, the temperature change measurement may be a relevant indicator. The objective of the present thesis is therefore to establish a thermal monitoring system of the heart in a way to evaluate the quality of the cardioplegia perfusion during cardiovascular surgery.Among the non-invasive thermal monitoring methods implantable in the operating room, the ultrasonic thermometry and infrared thermography caught our attention. In the first stages of the study, a direct method of ultrasonic thermometry based on the echo tracking is performed on in-vitro samples with 2.25 MHz ultrasonic sensor in a temperature range between 10 to 30°C. The ultrasonic characterization of the heart muscle and the laboratory experiments brought to the forth an environmental complexity requiring prior calibration that may be difficult to implement in operational conditions. However, the technique has a satisfactory measurement accuracy for temperature variations of less than 10°C.An adjustment model is then proposed to identify the in-depth warming trend of the heart thanks to the surface temperature measurement performed by thermal infrared camera and the medium thickness estimated by ultrasound. The model is validated by finite element simulations and experiments realized on ghosts and in-vitro heart samples.Finally, the device is experimented on in-vivo animal models while hypothermic cardioplegia were conducted. Conclusive results were obtained on the heart thermal monitoring. In particular, the surface temperatures acquired by infrared thermography and the thickness estimation of the ventricular walls by ultrasound allowed an estimation of the myocardial-warming trend.This feasibility study has demonstrated the possibility of heart thermal monitoring, noninvasively and appropriate in real time. After specific adaptation, this device could be implemented during cardiovascular interventions and provide a valuable indicator for the surgeons about the efficacy of myocardial protection.
82

Fluctuations de température en aval d'une jonction orthogonale d'écoulements turbulents de températures différentes

Menanteau, Sébastien 20 March 2012 (has links)
La problématique associée à ce travail de thèse concerne la détermination des causes de fatigue thermique dans des conduites hydrauliques. Ce travail porte plus particulièrement sur l’étude d’une zone de mélange orthogonale dans laquelle débouchent deux écoulements à différentes températures et présentant des régimes dynamiques turbulents. Ce type de configuration est utilisé afin de favoriser la baisse de température de l’écoulement (ou l’augmentation de température selon les cas). Pour des valeurs élevées du nombre de Reynolds et des écarts de températures des écoulements en confluence, la charge thermique engendrée par les fluctuations pariétales de température peut entraîner la formation de fissures dans les canalisations.Pour faire face à ce problème, les méthodes de dimensionnement des conduites hydrauliques mettent en évidence la nécessité de connaître la charge thermique imposée sur la paroi sensible. Le besoin attendu en termes de caractérisation dynamique et thermique de ces écoulements est à l’origine de ce projet de recherche qui s’attache ainsi à déterminer pour une configuration industrielle simplifiée, les phénomènes dynamiques et thermiques instationnaires et tridimensionnels à proximité de la paroi. Pour cela, l’étude s’organise en deux phases. Une approche expérimentale, faisant appel à la vélocimétrie par images de particules et la thermographie infrarouge, est mise en oeuvre dans un écoulement turbulent à la jonction entre une conduite de section rectangulaire et un piquage cylindrique. L’étude expérimentale permet de mesurer l’effet de différents paramètres de l’écoulement (régime dynamique, rapport des vitesses de l’écoulement, écart de température). Une des configurations expérimentales est de plus modélisée par simulations des grandes échelles dans laquelle le transfert thermique conjugué entre le fluide et la paroi d’intérêt est pris en compte. Les champs statistiques de vitesse et température issus du calcul numérique sont comparés à la base de données expérimentale. L’analyse des mécanismes thermodynamiques près de la paroi et dans la paroi, est de plus réalisée au moyen des grandeurs statistiques de l’écoulement, des corrélations de vitesse-température et de l’enregistrement temporel de sondes numériques placées dans l’écoulement et dans la paroi. / This research work originates from thermal stress issues in hydraulic pipes. It specifically focuses on determination of thermal load created by mixing flows in orthogonal pipe junctions. Such mixing zones are commonly used to cool or heat the main flow. For high Reynolds number values and high difference of temperature of the two flows, thermal load created by strong temperature fluctuations at the wall can initiate and propagate cracks through the pipe. Standards in pipe design pointed out the need in knowing these thermal loads applied at the downstream junction wall. Thus, this study aims to characterize three-dimensional and unsteady dynamical and thermal phenomena in a simplified industrial configuration. First, an experimental investigation based on particle image velocimetry and infrared thermography has been carried out on a cylindrical jet pipe flowing through a main rectangular channel flow. Different parameters have been studied such as Reynolds number influence, velocity ratio between secondary and main flow and temperature difference. One of the experimental configurations has also been investigated using numerical simulations. LargeEddy Simulations with conjugate heat transfer model has been developed and compared to the experimental database. Dynamics and Thermal mechanisms have been analysed near the wall and within the wall with obtained statistical flow fields, velocity-temperature moments and numerical probes extracted from fluid and solid parts.
83

Simultaneous characterization of objects temperature and radiative properties through multispectral infrared thermography / Caractérisation conjointe de la température et des propriétés radiatives des objets par thermographie infrarouge multispectrale

Toullier, Thibaud 06 November 2019 (has links)
L'utilisation de caméras infrarouges bas coûts pour la surveillance long-terme d'infrastructures est prometteuse grâce aux dernières avancées technologiques du domaine. Une mesure précise de la température des surfaces observées in-situ se heurte au manque de connaissance des propriétés radiatives de la scène. L'utilisation d'une instrumentation multi-capteurs permet d'affiner le modèle de mesure afin d'obtenir une estimation plus précise de la température. A contrario, il est montré qu'il est toujours possible d'exploiter des données climatiques en ligne pour pallier un manque de capteur. Des méthodes bayésiennes d'estimation conjointe d'émissivité et de température sont ensuite développées et comparées aux méthodes de la littérature. Un simulateur d'échanges radiatifs diffus de scènes 3D a été implémenté afin de tester ces différentes méthodes. Ce logiciel utilise l'accélération matérielle de la machine pour réduire les temps de calcul. Les résultats numériques obtenus mettent en perspective une utilisation avancée de la thermographie infrarouge multi-spectrale pour la surveillance de structures. Cette estimation conjointe permet alors d'obtenir un estimé de la température par thermographie infrarouge avec une incertitude connue. / The latest technological improvements in low-cost infrared cameras have brought new opportunities for long-term infrastructures monitoring. The accurate measurement of surfaces' temperatures is facing the lack of knowledge of radiatives properties of the scene. By using multi-sensors instrumentation, the measurement model can be refined to get a better estimate of the temperature. To overcome a lack of sensors instrumentation, it is shown that online and free available climatic data can be used. Then, Bayesian methods to estimate simultaneously the emissivity and temperature have been developed and compared to literature's methods. A radiative exchange simulator of 3D scenes have been developed to compare those different methods on numerical data. This software uses the hardware acceleration as well as a GPGPU approach to reduce the computation time. As a consequence, obtained numerical results emphasized an advanced use of multi-spectral infrared thermography for the monitoring of structures. This simultaneous estimation enables to have an estimate of the temperature by infrared thermography with a known uncertainty.
84

Caractérisation thermique et lumineuse de diodes électroluminescentes en charge par méthodes locales non intrusives : influence du luminophore / Thermal and luminous characterization of charged light emitting diodes (LED) by local non-intrusive methods : effect of phosphor

Lacourarie, Fiona 17 July 2015 (has links)
Le marché des diodes électroluminescentes (LEDs) de puissance est en perpétuelle croissance depuis une vingtaine d’années. Le marché de l’éclairage évolue car les besoins ont changé : nous souhaitons, par exemple, aujourd’hui réduire la consommation électrique, ou avoir des éclairages plus flexibles (couleur, cycle d’allumage, encombrement, …). Les LEDs de puissance permettent d’apporter des solutions où les autres éclairages font défauts. Une étude comparative est menée entre les LEDs et les autres sources d’éclairages. Une LED de puissance émettant une lumière blanche est constituée d’une puce semi-conductrice, d’un substrat, d’un PAD et d’une optique primaire. Différentes méthodes permettent d’obtenir de la lumière blanche avec des LEDs : plusieurs puces, une puce avec un ou des luminophores, ou la méthode PRS-LED. Le luminophore a un rôle optique important et un rôle thermique non négligeable. Après avoir été excité par la lumière émise de la puce, il réémet de la lumière dans une longueur d’onde supérieure. L’efficacité de ce processus dépend de nombreux paramètres, comme la mise en oeuvre du luminophore ou le type de luminophore utilisé. L’étude et la caractérisation des propriétés optiques et thermiques sont faites pour des LEDs commerciales, composées d’une même puce émettant de la lumière bleue, avec et sans luminophore jaune. Afin de maitriser le maximum de facteurs, nous avons mené une étude et un dimensionnement du circuit imprimé (PCB) sur lequel va être implanté nos LEDs. Dans le but d’évaluer les matériaux constituant les LEDs, des analyses au microscope à balayage électronique et par microsonde ont été menées. Ces travaux ont permis de révéler, notamment, la position de la jonction p-n dans la puce et la composition de la couche de luminophore par deux types différents. De plus, afin d’améliorer notre compréhension, une étude comparative a été menée sur trois luminophores jaunes. Ensuite, les deux types de LEDs, puce nue et puce avec luminophore, ont été testés dans le but d’obtenir le flux lumineux et le rendement des LEDs. La caractérisation optique nous a amené à créer un banc pour obtenir la luminance énergétique spectrale sur une partie minime de la puce. D’autre part, nous nous intéressons à la température de jonction de la puce nue, que nous mesurons par différentes méthodes, dont la thermographie infrarouge. Pour cela, l’émissivité a été estimée pour la puce nue et la puce avec luminophore. Puis nous comparons aussi ces différentes méthodes pour le calcul de la résistance thermique Rth j-PAD entre la jonction et le PAD. Le maillage de fils conducteurs implanté sur la surface de la puce est modélisé électriquement. Cette étude, qui est composée de niveaux progressifs de modélisation, permet de comprendre la répartition du courant électrique qui traverse la jonction, et ainsi d’appréhender la répartition du flux lumineux et de la température au niveau de la surface de la puce. Après, un modèle thermo-optique décrit les phénomènes présents au niveau de la jonction d’une puce nue : la conversion de la puissance électrique en lumière bleue et en chaleur, et les transferts de chaleur. Nous complétons ce premier modèle pour obtenir un modèle d’une puce avec le luminophore. Ce dernier modèle prend en compte la photo-conversion du luminophore avec le calcul de flux lumineux à la sortie du luminophore et le calcul de la chaleur due à la photo-conversion. La résolution de ce modèle nous permet d’obtenir la température de jonction d’une puce avec luminophore. La conservation d’énergie du modèle est aussi vérifiée. Le modèle thermo-optique est appliqué à une cartographie de température de surface afin d’obtenir une cartographie de la température de jonction. Ces cartographies sont regroupées avec les clichés de thermographie infrarouge et de luminance énergétique. / The high brightness LED market is constantly growing last twenty years. The lighting market is changing as needs have changed: we would like, for example, reduce power consumption, or have more flexible lighting (color, lighting cycle, dimensions ...). High brightness LEDs help provide solutions where others are lighting defects. A comparative study is conducted between the LEDs and other lighting sources.The operation of a high brightness LED emitting white light is explained with the description of each element: chip, substrate, the PAD and optics. Then the different methods of obtaining white light with LEDs are compared: several chips, a chip with one or more phosphors, or PRS-LED method. The phosphor has a significant optical role and an important thermal role. After being excited by the light emitted from the chip, it re-emits light in a greater wavelength. The effectiveness of this process depends on many parameters, such as the implementation of the phosphor, or the type of phosphor used. The study and characterization of optical and thermal properties are made for commercial LEDs, composed of a single chip emitting blue light with and without yellow phosphor. To master the maximum factors, we conducted a study and design of the printed circuit board (PCB) on which will be implanted our LEDs. In order to evaluate the materials constituting the LEDs, analyzes made at scanning electron microscope, and by microprobe were conducted. This work has revealed in particular the position of the p-n junction in the chip, and the composition of the phosphor layer of two different types. Moreover, to improve our understanding, a comparative study will be conducted on three yellow phosphors. Then the two types of LEDs, bare chip and chip with phosphor, were tested in order to obtain the luminous flux and efficiency of LEDs. The optical characterization has led us to create a bench for spectral radiance over a small portion of the chip. Furthermore, we are interested in the junction temperature of the bare chip, which we measure by various methods, including infrared thermography. For this, the emissivity was estimated for the bare chip and the chip with phosphor. Then we also compare these different methods to calculate the thermal resistance Rth j-PAD between the junction and the PAD. The mesh of conductive wires, implanted on the surface of the chip, is electrically modeled. The study, which is composed of three progressive levels of modeling, provides an understanding of distribution of the electric current through the junction, and thus to understand the distribution of the light flow and temperature at the surface of the chip. Afterwards, an optical-thermal model describes the phenomena present at the junction of a bare chip: converting electrical power into blue light and heat, and heat transfer. We complete this first model for a model of a chip with the phosphor. This model takes into account the photo-conversion of the phosphor with the calculation of the luminous flux at the output of the phosphor and the calculation of the heat due to the photo-conversion. The resolution of this model allows us to obtain the junction temperature of a chip with phosphor. The model of energy conservation is also verified. The optical-thermal model is applied to a surface temperature mapping in order to obtain a mapping of the junction temperature. These maps are combined with pictures of infrared thermography and radiance.
85

L’impact des systèmes de logement alternatifs sur la santé et les performances des poules pondeuses

Denis, Éloïse 08 1900 (has links)
Alors que les producteurs d'œufs canadiens font la transition des cages conventionnelles vers les systèmes de logement alternatifs, il est important de déterminer l’impact de ceux-ci sur le bien-être et les performances des poules pondeuses. L’objectif de cette étude était d’évaluer la prévalence de déviation du bréchet, de fracture du bréchet, de dermatite du coussinet plantaire et l’état du plumage dans les fermes commerciales du Québec, Canada. Le taux de ponte, la mortalité cumulée, la consommation alimentaire, l’épaisseur de la coquille, le poids de l’œuf, la force de la coquille, l’unité Haugh et la prévalence d’œufs sales et craqués ont été utilisés pour déterminer la performance du troupeau. L’utilisation de la thermographie infrarouge comme outil diagnostique pour les fractures du bréchet et les dermatites du coussinet plantaire a également été évaluée. Les données révèlent que les poules maintenues en volières présentent une prévalence de fracture du bréchet (P=0,011) et une mortalité (P=0,0049) plus élevée, en plus de produire des œufs avec une épaisseur de coquille supérieure comparativement aux poules maintenues en cages enrichies (P=0,0049). Une faible consommation alimentaire était corrélée avec une prévalence élevée de poules présentant une perte de plumes (P < 0,05) et une consommation alimentaire élevée était corrélée avec un poids d’œufs élevé (P < 0,05). Les systèmes de logement n’ont pas influencé les autres paramètres étudiés. Globalement, les volières impactent négativement les fractures du bréchet, les dermatites du coussinet plantaire ainsi que la mortalité et la thermographie infrarouge n’est pas un outil diagnostique fiable. / As Canadian egg farmers transition their flocks from conventional cages to alternative housing systems, it is important to evaluate the impact of the latter on the performance and welfare of laying hens. To this end, the present study investigates the prevalence of keel bone deviation, keel bone fracture, footpad dermatitis and feather coverage in commercial flocks in Quebec, Canada, housed in enriched cages and aviaries. Mean egg production, cumulative mortality, feed intake, shell thickness, egg weight, shell strength, Haugh unit, and the prevalence of cracked or dirty eggs were used as measures of flock performance. The present study also investigates the use of infrared thermography as a diagnostic tool for keel bone fractures and footpad dermatitis in hens. Our data show that hens housed in aviaries have a significantly higher prevalence of keel bone fracture (P=0.011) and cumulative mortality (P=0.0049) but that the egg shells of aviary hens are significantly thicker than their counterparts in enriched cages (P=0.0049). While thermal imaging could not distinguish between hens with and those without fractures, footpad temperatures were significantly higher in hens with severe dermatitis (P<0.01). Furthermore, a low feed intake positively correlated with damaged feather coverage (P<0.05), while high feed intake correlated with high egg weight (P<0.05). The other parameters studied were not influenced by the type of housing. Overall, aviary housing negatively impacted keel bone fractures, footpad dermatitis and mortality and infrared thermography is not a valid diagnostic tool for keel fracture and footpad dermatitis in hens.
86

Thermographie et shearographie appliquées au contrôle non-destructif d'interfaces entre de l'adhésif époxy et du CFRP

Théroux, Louis-Daniel 20 April 2018 (has links)
Le sujet de ce mémoire porte sur l'étude du contrôle non-destructif de structure de béton renforcé par collage de CFRP (carbon fiber reinforced polymer) par shearographie et thermographie active couplées. La méthode d'excitation utilisée conjointement lors de la mise en œuvre de ces deux méthodes est un rayonnement thermique conditionné temporellement par un signal carré. L'observation du champ des températures de surface et des déplacements hors plan de la surface permet la détection et la caractérisation de défauts. Dans un premier temps, des tests de faisabilité ont été conduits pour valider si l'utilisation d’une contrainte thermique de type créneau autorisait des mesures shearographiques (cela ayant été déjà validé dans le cas de la thermographie infrarouge active). Cette série de test s’étant avérée concluante, une étude numérique par modélisation aux éléments finis a été réalisée sous Comsol®. Cette étude numérique a permis de mieux appréhender les résultats obtenus expérimentalement mais aussi de conduire une étude de l’influence de différents paramètres. Des outils d'analyses ont été développés et ont permis de mettre en évidence, entre autre, qu'une évaluation quantitative des défauts était possible.
87

Thermographie active appliquée à la caractérisation in situ de parois de bâtiment / Active thermal applied in situ characterization of building walls

Chaffar, Khaled 11 July 2012 (has links)
Les préoccupations environnementales actuelles visent à réduire les consommations énergétiques. Dans une démarche d’amélioration des bâtiments existants, l'étude du comportement thermique d’une paroi n'est pas aisée du fait de la méconnaissance de ses propriétés thermophysiques réelles. Ces paramètres sont pourtant prépondérants pour la phase d'optimisation économique des opérations de réhabilitation ou pour vérifier ses performances in situ. Il apparaît donc important de pouvoir caractériser les parois de bâtiment en place. Notre travail vise à développer une méthode de caractérisation thermique d’une paroi adaptée aux applications in situ basée sur une approche active. Le principe d'identification consiste à solliciter thermiquement une face d’accès en imposant un flux de chaleur sous forme d’un créneau et à étudier la réponse en température enregistrée par thermographie infrarouge sur l’autre face. A partir de signaux de flux et de températures mesurés aux limites de la paroi, les propriétés thermophysiques de la paroi seront estimées par méthode inverse. Nous nous sommes dans un premier temps intéressés aux parois homogènes. Le schéma d’inversion est construit autour d’un modèle numérique décrivant la réponse de la paroi suivant la méthode des différences finies en 1D. L’identification de la conductivité thermique et de la chaleur volumique de la paroi est réalisée en optimisant le groupement de paramètres qui permet de minimiser l’écart entre la température normalisée mesurée et la température normalisée simulée. Le coefficient d’échange surfacique global est également identifié à partir du même essai. Dans ce travail, la méthode a été appliquée à une paroi homogène en carreaux de plâtre mise en place au laboratoire. Elle a une épaisseur de 6.5 cm. Cette technique a été utilisée pour les parois multicouches de bâtiments. Les résultats issus de cette procédure d’inversion ont été comparés à des valeurs de référence obtenues à partir d’une procédure classique (NF EN 12664-méthode fluxmétrique). Une bonne concordance des résultats est obtenue. Une autre partie représente les essais in situ. / Current environmental concerns are intended to reduce energy consumption. In a process of improving existing buildings, the study of the thermal behavior of a wall is not easy because of the ignorance of its real thermophysical properties. These parameters are yet to dominate the economic optimization phase of the rehabilitation or to check its performance in situ. It therefore appears important to characterize the walls of existing building. Our work aims to develop a method of thermal characterization of a wall suitable for in situ applications based on an active approach. The principle of identification is to apply a heat-face access by imposing a heat flux in the form of a pulse and to study the temperature response recorded by infrared thermography on the other side. From signal flow and temperature measured at the limits of the wall, the thermophysical properties of the wall will be estimated by inverse method. We are at present interested in homogeneous walls. The inversion scheme is built around a digital model describing the response of the wall following the finite difference method in 1D. The identification of the thermal conductivity and heat volume of the wall is achieved by optimizing the group of parameters which minimizes the normalized difference between the temperature measured and the temperature standard simulated. The overall Global exchange coefficient is also identified from the same test. In this work, the method was applied to a homogeneous wall tile plaster introduction to the laboratory. It has a thickness of 6.5 cm. This technique was used for multilayer walls of buildings. The results of this inversion procedure were compared with reference values obtained from a standard procedure (DIN EN 12664-flow meter methods). A good agreement is obtained. Another part is the in situ tests.
88

Identification expérimentale du comportement d'un fuselage composite : détection de défauts par mesures de champs / Experimental identification of the behavior of a composite fuselage : defects detection by full field measurements

Peronnet, Élodie 04 October 2012 (has links)
Le contexte de ce travail concerne le process d'Infusion de Résine Liquide (LRI) développé dans le cadre du projet « FUSelage COMPosite » par DAHER SOCATA. Ce process de fabrication permet de réaliser des pièces de formes complexes et des panneaux entiers de fuselage en composites, ce qui réduit considérablement les étapes d'assemblages et donc les temps de production. Les travaux de thèse portent sur l'identification expérimentale du comportement d'un fuselage composite. Ce travail se divise en deux parties qui sont la qualification du contrôle non destructif (CND) par rapport à une taille de défaut critique et l'identification du comportement d'une structure composite orthotrope en présence de ce défaut. Le premier volet consiste à évaluer les techniques de CND basées sur des mesures de champs (acoustiques, thermiques et densimétriques), capables de détecter des défauts internes de types délaminage et porosité au sein de structures composites monolithiques et sandwichs, et fournissant une visualisation des résultats par une cartographie de défauts 2D ou 3D. Le choix de ces méthodes a été motivé par la volonté de DAHER SOCATA d'acquérir de nouvelles compétences en matière de CND. Le deuxième volet consiste à évaluer les paramètres élastiques d'une structure composite orthotrope (structure comprenant une zone saine et une zone localement dégradée) via une procédure d'identification, à partir de mesures de champs, globale et locale par recalage de modèles éléments finis. Cette procédure se décompose en quatre parties avec tout d'abord l'identification des propriétés de la structure saine, ensuite la localisation de la zone dégradée, l'intégration de celle-ci dans le modèle éléments finis, et l'identification des propriétés de cette dernière. / The context of this work concerns the process of Liquid Resin Infusion (LRI) developed under the project "composite fuselage" by DAHER SOCATA. This manufacturing process can produce parts with complex shapes and entire panels of composite fuselage, reducing assembly steps and therefore the production time. The thesis work focused on the experimental identification of the behavior of a composite fuselage. This work is divided into two parts which are the qualification of non destructive testing (NDT) compared to a critical defect size and the identification of the behavior of an orthotropic composite structure with defect. The first part is to evaluate the NDT techniques based on full field measurements (acoustic, thermal and densimetric), capable of detecting internal defects as porosities and delaminations in monolithic and sandwich composite structures, and providing a results visualization by a 2D or 3D defects map. The choice of these methods was motivated by DAHER SOCATA which wants to learn new NDT skills. The second part is to evaluate the elastic parameters of an orthotropic composite structure (structure composed by a virgin zone and a damaged zone) through an identification process from field measurements, by global and local step. This procedure is divided into four parts with two identification steps and a image processing step.
89

Etude du couplage thermomécanique du PEHD par essais mécaniques et inversion d'images infrarouges / A study of the termomechanical coupling in hdpe characterised with mechanical tests and infrared images inversion

Renault, Norbert 13 December 2007 (has links)
Ce travail vise à approfondir la connaissance du comportement mécanique de polymères structurés sur de multiples échelles. Il repose sur l'acquisition simultanée d'informations couplées relatives à la mécanique, à la thermique et à la microstructure. Nous avons à cet effet étudié le comportement du Polyéthylène Haute Densité (PEHD) sous sollicitations de traction à déformation contrôlée à l'aide de trois techniques optiques utilisées in situ simultanément : (i) Le système Vidéotraction® pour l'accès aux contraintes et aux déformations vraies. (ii) La thermographie infrarouge pour l'accès aux sources thermiques. (iii) Une technique de rétrodiffusion de lumière (ISLT) pour l'accès à une forme d'endommagement. Le corps du travail porte sur la reconstruction des sources thermiques 2D à partir de cartographies des champs de température mesurés au cours d'essais. Le problème inverse de reconstruction des champs de sources ther-miques est résolu par deux méthodes différentes : minimisation sous contrainte avec formulation adjointe et décomposition modale. Des techniques de régularisation du problème sont décrites en détail pour chaque méthode. D'autre part, la technique ISLT nous permet de suivre l'endommagement : l'apparition progressive de "mi-crocavités" isotropes puis un développement d'une forte anisotropie pendant la phase de durcissement hyperélastique. Nous montrons que ces informations sur la microstructure viennent corroborer les phénomènes observés sur la source thermique. Nous replaçons alors l'ensemble des informations obtenues dans le contexte d'une modélisation thermodynamique des lois de comportement. Une étude de sensibilité aux paramètres du modèle est développée, ce qui conduit à une réduction du modèle adaptée à leur bonne estimation / This research aims at looking further into current knowledge of the mechanical behavior of semi-crystalline polymers at multiple scales. It relies on the simultaneous acquisition of coupled information relating to me-chanical, thermal and microstructural behaviors. For this purpose, we have studied the response of High Density Polyethylene (HDPE) under tensile tests with controlled strain rates, using three optical techniques : (i) Vidéotraction®, a videoextensemeter to access the true stress and strain. (ii) Infrared thermography to access the thermal sources evolution. (iii) Backscattering of Incoherent Light (ISLT technique) to access information on damage mechanisms. The core of the research concerns the reconstruction of the 2D thermal sources starting from temperature fields maps measured during the test. This ill-posed problem has been solved with two different methods : A constrained optimization based on the adjoint formulation and a minimization based on a reduced spectral model. The regularization tools used in the problem are detailed for each method. The ISLT technique allows to monitor damaging processes due to crazing : the creation of isotropic micro-cavities followed by the development of a strong anisotropy during the hardening phase. We show that these information at microstructural level confirm the evolutions of the heat source thermal. All these experimental information are finally considered within a thermodynamical framework used for deri-ving constitutive laws. A sensitivity analysis applied to the parameters of our law led to a reduced model that is more appropriate for their proper estimation
90

Caractérisation thermique de matériaux anisotropes à hautes températures / Thermal characterization of anisotropic materials at high temperatures

Souhar, Youssef 20 May 2011 (has links)
Le sujet de l'étude concerne la caractérisation thermique à hautes températures de matériaux anisotropes dont la diffusivité thermique varie selon la direction considérée. Cette mesure de la diffusivité est permise par l'observation des variations transitoires de température d'un matériau soumis à un flux de chaleur de type impulsionnel. L’excitation provient d’un Laser et la mesure de température est réalisée par thermographie infrarouge sur la face opposée à l'excitation thermique. Le champ de température ainsi obtenu permet de déterminer les trois diffusivités du matériau selon ses directions d'anisotropie. En effet, grâce à des transformations intégrales du champ de température, il est possible d'obtenir un modèle théorique décrivant les variations de température au sein du matériau. Les estimations des diffusivités s'obtiennent alors par la minimisation de la somme des écarts quadratiques entre les modèles théoriques et leurs équivalents expérimentaux. Il s'agit de problèmes d'optimisation non linéaire et les estimations sont réalisées dans le domaine des fréquences spatiales et dans le temps grâce à une inversion numérique de Laplace. Basée sur des dispositifs optiques, cette méthode est non intrusive et grâce aux modèles analytiques les mesures sont rapides et précises même à haute température. La méthode ainsi que le nouveau banc expérimental mis en place rendent possible la mesure des trois diffusivités en une unique expérience pour des excitations de forme quelconque en espace et non nécessairement Dirac en temps / The study concerns the thermal characterization at high temperatures of anisotropic materials whose thermal diffusivity varies according to the direction considered. This measurement of diffusivity is allowed by the observation of the transient variations of temperature of a material subjected to a heat pulse source. The excitation is performed by a Laser and the temperature measurement is carried out by infrared thermography on the opposite face of the thermal excitation. The temperature field thus obtained makes it possible to determine the three diffusivities of the material according to its directions of anisotropy. Indeed, thanks to integral transforms of the temperature field, it is possible to obtain a theoretical model describing the temperature variations within the material. The estimates of diffusivities are then obtained by the minimization of the sum of squared residuals between the theoretical models and their experimental equivalents. These are problems of nonlinear optimization and the estimations are carried out in the spatial frequency domain and in time thanks to a numerical inversion of Laplace. Based on optical devices this method is non-intrusive and thanks to the use of analytical models the estimations are fast and accurate even at high temperatures. The method and the new experimental facility make it possible to estimate the three thermal diffusivities in a single experiment and this for excitations of any shape in space and not necessarily Dirac’s delta function in time

Page generated in 0.0813 seconds