• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 675
  • 123
  • 72
  • 67
  • 67
  • 53
  • 45
  • 8
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1484
  • 1484
  • 323
  • 323
  • 277
  • 237
  • 218
  • 161
  • 130
  • 128
  • 126
  • 115
  • 115
  • 110
  • 108
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Modeling the Dynamic Composition of Engineered Cartilage

Wilson, Christopher G 26 March 2002 (has links)
Experimental studies indicate that culturing chondrocytes on biodegradable polymeric scaffolds may yield“engineered" cartilage for the replacement of tissue lost to injury or diseases such as osteoarthritis. A method of estimating the outcome of cell-polymer cultures would aid in the design and evaluation of engineered tissue for therapeutic use. The goals of this project were to develop, validate, and apply first-generation mathematical models that describe the kinetics of extracellular matrix (ECM) deposition and scaffold degradation in cell-polymer constructs cultured in vitro. The ECM deposition model is based on a product-inhibition mechanism and predicts an asymptotic, exponential increase in the concentration of ECM molecules found in cartilage, including collagen and glycosaminoglycans (GAG). The scaffold degradation model uses first-order kinetics to describe the hydrolysis of biodegradable polyesters in systems not limited by diffusion. Each model was fit to published data describing the accumulation of GAG and collagen, as well as the degradation of poly glycolic acid (PGA) and poly lactic acid (PLA), respectively. As experimental validation, cell-polymer constructs (n = 24) and unseeded scaffolds (n = 24) were cultured in vitro, and biochemical assays for GAG and collagen content, as well as scaffold mass measurements, were performed at 1, 2, 4, 6, 8, or 10 weeks of culture (n = 8 per time point). The mathematical models demonstrate a moderate to strong goodness of fit with the previously published data and our experimental results (R2=0.75-0.99). These models were also combined to predict the temporal evolution of total construct mass with reasonable accuracy (30% RMS deviation). In ongoing work, estimates of biochemical composition derived from these models are being proposed to predict the mechanical properties and functionality of the constructs. This modeling scheme may be useful in elucidating more specific mechanisms governing ECM accumulation. Given their potential predictive power, these models may also reduce the cost of performing long-term culture experiments.
142

Fibre-reinforced hydrogels : biomimetic scaffolds for corneal tissue engineering

Tonsomboon, Khaow January 2015 (has links)
No description available.
143

Incorporation of surfactants into electrospun scaffolds for improved bone tissue engineering applications

Coverdale, Benjamin January 2016 (has links)
Electrospinning is a process by which micro and nanofibrous scaffolds can be easily fabricated to mimic structures such as the extracellular matrix of bone. A number of materials have been used to fabricate such scaffolds making the process an extremely versatile tool in the field of bone tissue engineering. Many scaffolds however are hydrophobic, leading to poor cellular attachment and proliferation, whilst the actual process of electrospinning is highly variable, producing irregular scaffolds that can ultimately influence cell invasion and differentiation. The focus of this thesis was to address the issues of poor biocompatibility and irregular scaffold production in three commonly used polymers each with different mechanical properties and degradation profiles. Poly (ε-caprolactone) (PCL), polyethylene terephthalate (PET) and poly lactic-co-glycolic acid (PLGA) were functionalised with surfactants in order to improve the biocompatibility and osteoinductive properties of electrospun scaffolds, whilst electrospinning equipment was modified to improve uniformity of scaffold production. Reducing variables known to affect scaffold formation such as temperature and humidity through the use of an environmental stability cabinet improved the reproducibility of scaffolds. The introduction of a Faraday cage, a larger electrode and a negative mandrel potential also improved the quality and quantity of electrospun fibres collected. Lecithin was selected as an appropriate additive for both improving biocompatibility and uniformity of electrospun fibres as it is naturally occurring and induced dose dependent reductions in water contact angle, allowing tailored hydrophobicity. Through gravimetric determination of pore sizes coupled with mathematical modelling, the addition of lecithin was found to reduce both mean fibre diameter and pore size in all scaffolds, improving scaffold homogeneity. At low concentrations (i.e. 2 %) lecithin generally did not affect the mechanical properties of scaffolds, however significant improvements in tensile strength for PCL and nanoindentation for PET were evident, indicating these scaffolds remained suitably strong for bone regeneration purposes. Reduced hydrophobicity acted to improve cellular attachment of Saos-2 osteoblasts to polymers, whilst proliferation on all scaffolds was similar to TCP controls. Furthermore, lecithin incorporation induced osteoinduction, as bone marrow mesenchymal stem cells seeded on these hybrid scaffolds expressed upregulated gene expression for alkaline phosphatase, collagen 1, osteocalcin and osteopontin. In conclusion, these scaffolds, functionalised with lecithin, improve the homogeneity of fibrous mats allowing increased reproducibility and efficiency of the electrospinning process. Furthermore, the improved biocompatibility and osteoinductivity that lecithin presents, allows for the production of more suitable electrospun scaffolds in the field of bone tissue engineering.
144

mCCDcl1 cells exhibit a transitional phenotype : implications for collecting duct plasticity

Assmus, Adrienne Madeleine January 2018 (has links)
The cortical collecting duct of the mammalian kidney plays a critical role in the regulation of body volume, sodium pH and osmolarity and is composed of two distinct cells types, principal cells and intercalated cells. Each cell type is detectable in the kidney by the localization of specific transport proteins such as Aqp2 and ENaC in principal cells and V-ATPase B1 and Cx30 in intercalated cells. mCCDcl1 cells have been widely used as a mouse principal cell line on the basis of their physiological characteristics. In this study, the mCCDcl1 parental cell line and three sub-lines cloned from isolated single cells (Ed1, Ed2, and Ed3) were grown on filters to assess their transepithelial resistance, transepithelial voltage, equivalent short circuit current and expression of the cell-specific markers Aqp2, ENaC, V-ATPaseB1 and Cx30. The parental mCCDcl1 cell line presented amiloride-sensitive electrogenic sodium transport indicative of principal cell function, however immunocytochemistry and RT-PCR showed that some cells expressed the intercalated cell-specific markers V-ATPase B1 and Cx30, including a subset of cells also positive for Aqp2 and ENaC. The three subclonal lines contained cells that were positive for both intercalated and principal cell-specific markers. The vertical transmission of both principal and intercalated cell characteristics via single cell cloning, reveals the plasticity of mCCDcl1 cells, and a direct lineage relationship between these two physiologically important cell types, and is consistent with mCCDcl1 cells being precursor cells. For observation of live mCCDcl1 in an environment closer to in vivo conditions, a model of collecting duct was designed and developed using 3D printing of porous polymers. mCCDcl1 were cultured successfully and demonstrated improved characteristics compared to classic culture such as improved lifespan, different morphology and increased protein expression, and retained their phenotypic plasticity.
145

Fabrication and characterization of NCO-sP(EO-stat-PO)- crosslinked and functionalized electrospun gelatin scaffolds for tissue engineering applications / Herstellung und Charakterisierung von elektrogesponnenen Nanofasern aus Gelatine und NCO-sP(EO-stat-PO) für Tissue Engineering Anwendungen

Wiesbeck, Christina January 2019 (has links) (PDF)
In Tissue Engineering, scaffolds composed of natural polymers often show a distinct lack in stability. The natural polymer gelatin is highly fragile under physiological conditions, nevertheless displaying a broad variety of favorable properties. The aim of this study was to fabricate electrospun gelatin nanofibers, in situ functionalized and stabilized during the spinning process with highly reactive star polymer NCO-sP(EO-stat-PO) (“sPEG”). A spinning protocol for homogenous, non-beaded, 500 to 1000 nm thick nanofibers from different ratios of gelatin and sPEG was successfully established. Fibers were subsequently characterized and tested with SEM imaging, tensile tests, water incubation, FTIR, EDX, and cell culture. It was shown that adding sPEG during the spinning process leads to an increase in visible fiber crosslinking, mechanical stability, and stability in water. The nanofibers were further shown to be biocompatible in cell culture with RAW 264.7 macrophages. / Tissue Engineering Scaffolds aus natürlichen Polymeren zeigen häufig mangelnde Stabilität, insbesondere unter physiologischen Bedingungen. Das natürliche Polymer Gelatine besitzt einige sehr vorteilhafte Eigenschaften für die Anwendung bei der Produktion künstlicher Körpergewebe. Beim Einsatz im menschlichen Organismus ist die Gelatine durch ihre Wasserlöslichkeit höchst fragil. Das Ziel dieser Arbeit war die Herstellung von Nanofaser-Scaffolds aus Gelatine mittels Elektrospinning und deren in situ Stabilisierung durch das Sternpolymer NCO-sP(EO-stat-PO) („sPEG“). Zunächst wurde ein Spinningprotokoll zur Fabrikation homogener, glatter, 500 bis 1000 nm dicker Nanofasern in verschiedenen Verhältnissen von Gelatine und sPEG erarbeitet. Mittels REM Bildgebung, Zugversuchen, Wasserinkubationsversuchen, FTIR, EDX und Zellkultur wurden die Fasern untersucht und charakterisiert. Es konnte gezeigt werden, dass die Zugabe von sPEG während des Spinningprozesses zu einer sichtbaren Quervernetzung der Fasern, sowie zu einem Anstieg der mechanischen Festigkeit und der Wasserstabilität führt. Des Weiteren wurde die Biokompatibilität der Nanofasern in der Zellkultur mit RAW 264.7 Makrophagen belegt.
146

Development of stem cell-based ACL- and tendon reconstruction / Entwicklung Stammzell-basierter Konstrukte für den Kreuzband- und Sehnenersatz

Haddad-Weber, Meike January 2010 (has links) (PDF)
Ruptures of the anterior cruciate ligament (ACL) and defects of the rotator cuff represent the most common ligament and tendon injuries in knee and shoulder. Both injuries represent significant implications for the patients. After an injury, the ACL and the rotator cuff both exhibit poor intrinsic healing capacities. In order to prevent further defects such as arthritis of the knee and fatty infiltration of the rotator cuff, surgical interaction is essential. In both cases, the currently used surgical techniques are far from optimal because even after the therapy many patients report problems ranging from pain and reduced mobility to complete dysfunction of the involved joint and muscles. Tissue engineering may be a possible solution. It is a promising field of regenerative medicine and might be an advantageous alternative for the treatment of musculoskeletal injuries and diseases in the near future. In this thesis, different tissue engineering based approaches were investigated. For the reconstruction of damaged or diseased ligaments and tendons, the use of MSCs and gene therapy with growth factors is especially suitable and possesses a great therapeutic potential. Therefore, the first method studied and tested in this thesis was the development of a biomaterial based construct for the repair of a ruptured ACL. The second approach represents a cell based strategy for the treatment of the fatty infiltration in the rotator cuff. The third approach was a combined cell, biomaterial, and growth factor based strategy for ACL ruptures. Biomaterial based ACL construct The implant is currently tested in a preclinical in vivo study in mini pigs. This proof-of-principle study is performed to validate the functional capability of the collagen fiber based implant under load in vivo and its population with fibroblasts which produce a ligamentogenic matrix. Cell based treatment of the fatty infiltration in the rotator cuff Regarding the treatment of the fatty infiltration of the rotator cuff in a rabbit model, the in vivo results are also promising. The group treated with autologous MSCs (+MSC group) showed a lower fat content than the untreated group (–MSC group) 6 weeks after the treatment. Furthermore, the SSP muscle of the MSC-treated animals revealed macroscopically and microscopically only few differences compared to the healthy control group. The exact underlying mechanisms leading to the positive results of the treatment are not yet fully understood and have therefore to be further investigated in the future. Cell, biomaterial, and growth factor based treatment of ACL ruptures Studies described in current literature show that collagen hydrogel scaffolds are not ideal for a complete ligament or tendon reconstruction, because of their insufficient mechanical stability. Introduced as an alternative and superior therapy, the combined strategy used in this thesis proves that the cultivation of BMP-12, -13, and IGF-1 transduced MSCs and ACL fibroblasts in a collagen hydrogel is successful. The results of the performed in vitro study reveal that the cells exhibit a fibroblastic appearance and produce a ligamentogenic matrix after 3 weeks. Furthermore, the adenoviral transduction of MSCs and ACL fibroblasts showed no negative effects on proliferation or viability of the cells nor was apoptosis caused. Therefore, the application of these cells represents a possible future therapy for a partial ligament and tendon rupture where the mechanical stability of the remaining ligament or tendon is sufficient and the healing can be improved substantially by this therapy. In general, prospective randomized clinical trials still have to prove the postulated positive effect of MSCs for the treatment of various musculoskeletal diseases, but the results obtained here are already very promising. Ideally, the treatment with MSCs is superior compared to the standard surgical procedures. Because of current safety issues the use of genetically modified cells cannot be expected to be applied clinically in the near future. In summary, the different tissue engineering approaches for novel therapies for musculoskeletal injuries and diseases invested in this thesis showed very promising results and will be further developed and tested in preclinical and clinical trials. / 7.2 Zusammenfassung Kreuzbandrupturen und Defekte im Bereich der Rotatorenmanschette stellen die häufigsten Band- und Sehnenverletzungen im Kniegelenk bzw. in der Schulter dar. Beide Verletzungen haben erhebliche Auswirkungen für den Patienten. Sowohl das Kreuzband als auch die Rotatorenmanschette weisen ein sehr schlechtes Heilungspotential nach einer Verletzung auf. Um weiteren Schäden wie einer Kniegelenksarthrose oder einer Verfettung der Rotatorenmanschette vorzubeugen, ist ein operativer Eingriff erforderlich. In beiden Fällen sind die zurzeit verwendeten Behandlungsstandards nicht optimal, da auch nach einer Therapie viele Patienten über Beschwerden klagen, die von Schmerzen und einer eingeschränkten Mobilität bis hin zu einer kompletten Dysfunktion des betroffenen Gelenks und Muskels reichen. Tissue Engineering ist ein zukunftsträchtiges Feld der Regenerativen Medizin und kann ein möglicher Lösungsansatz sein. Vor allem bei der Behandlung von muskuloskelettalen Verletzungen und Erkrankungen kann es zukünftig eine vorteilhafte Behandlungsalternative darstellen. In dieser Doktorarbeit wurden verschiedene Tissue Engineering-basierte Lösungsansätze untersucht. Zur Rekonstruktion von defektem Band- und Sehnengewebe sind sowohl der Einsatz von mesenchymalen Stammzellen (MSZ) als auch die Gentherapie mit Wachstumsfaktoren besonders geeignet und weisen ein großes therapeutisches Potential auf. Deswegen wurde in der vorliegenden Doktorarbeit als erster innovativer Therapieansatz ein Biomaterial-basiertes Konstrukt für den Ersatz eines gerissenen Kreuzbandes entwickelt und getestet. Der zweite Lösungsansatz stellt eine Zell-basierte Therapie zur Behandlung einer fettigen Atrophie der Rotatorenmanschette dar. Die dritte Methode kombiniert Zellen, Biomaterialien und Wachstumsfaktoren zur Therapie von Kreuzbandrupturen. Biomaterial-basiertes Kreuzbandkonstrukt Das Implantat wird zurzeit in einer präklinischen in vivo Studie am Mini Pig getestet. Diese Proof-of-Principle Studie wird durchgeführt, um die Funktionsfähigkeit der Kollagenfaser-basierten Implantate unter Belastung in vivo zu validieren und ihre Besiedelung mit Fibroblasten, die eine ligamentäre Matrix ausbilden, zu beobachten. Zell-basierte Behandlung der fettig-infiltrieten Rotatorenmanschette Auch bei der Behandlung der fettigen Infiltration der Rotatorenmanschette im Kaninchenmodel, wurden in vivo sehr viel versprechende Ergebnisse erzielt. Die mit autologen MSZ (+MSZ-Gruppe) behandelte Gruppe zeigte nach 6 Wochen einen deutlich geringeren Fettanteil als die unbehandelte Gruppe (-MSZ-Gruppe). Des Weiteren wies der SSP-Muskel aller MSZ-behandelten Tiere sowohl makroskopisch als auch mikroskopisch nur geringe Unterschiede im Vergleich zur gesunden Kontrollgruppe auf. Der genaue zugrunde liegende Mechanismus dieser erfolgreichen Behandlung konnte bisher noch nicht genau geklärt werden und muss in zukünftigen Studien weiter untersucht werden. Zell-, Biomaterial- und Wachstumsfaktor-basierte Behandlung von Kreuzbandrupturen In der aktuellen Literatur beschriebenen Studien zeigen, dass Kollagenhydrogel-konstrukte aufgrund der fehlenden biomechanischen Stabilität nicht geeignet sind für den kompletten Band- bzw. Sehnenersatz. Als vorteilhafte Behandlungsalternative wurde in der vorliegenden Arbeit eine kombinierte Strategie entwickelt und erfolgreich in vitro getestet: Die Kultivierung von BMP-12-, -13- bzw. IGF-1-transduzierten MSZ und Kreuzbandfibroblasten in einem Kollagenhydrogel verlief sehr viel versprechend und ergab, dass die Zellen nach 3 Wochen im Kollagenhydrogel eine fibroblastäre Morphologie aufweisen und eine ligamentäre Matrix ausbilden. Des Weiteren führte die adenovirale Transduktion der Zellen weder zu negativen Auswirkungen auf das Proliferationsverhalten noch auf die Vitalität der Zellen und löste auch keine Apoptose bei den transduzierten Zellen aus. Zukünftig kann der Einsatz dieser Zellen deswegen ein möglicher Ansatz zur Behandlung von Teilrupturen bei Bändern und Sehnen darstellen, bei denen die biomechanische Stabilität ausreichend ist und die Heilung durch die Therapie wesentlich verbessert wird. Im Allgemeinen müssen prospektive randomisierte klinische Studien zeigen, ob sich der positive Effekt der MSZ bei der Behandlung von Erkrankungen des muskuloskelettalen Systems in der Orthopädie und Unfallchirurgie bewährt, wobei die in der vorliegenden Arbeit erzielten Ergebnisse sehr Erfolg versprechend sind. Idealerweise erweist sich die Behandlung mit MSZ als deutlich vorteilhaft gegenüber den bisher etablierten chirurgischen Standardverfahren. Aufgrund der bestehenden Sicherheitsrichtlinien für den Einsatz von gentherapeutischen modifizierten Zellen ist mit deren Verwendung zur Behandlung von Band- und Sehnenerkrankungen in naher Zukunft nicht zu rechnen. Zusammenfassend führte die Untersuchung der unterschiedlichen Tissue Engineering Ansätze, die in dieser Doktorarbeit als neue Therapien zur Behandlung von muskuloskelettalen Verletzungen und Erkrankungen evaluiert wurden, zu sehr viel versprechende Ergebnisse. Diese Therapieansätze sollen weiterentwickelt und in präklinischen und klinischen Studien getestet werden.
147

DEVELOPMENT OF AN ELASTIC POLYMER-BASED DRUG DELIVERY SYSTEM FOR TISSUE REGENERATION

Unknown Date (has links)
In spite of the vast research on polymer-based tissue regeneration, extensive studies to develop an elastic and cell-promoting polymer biomaterial are still ongoing. However, using a renewable resource and a simple, environment-friendly synthesis route to synthesize an elastic polymer has not been successfully achieved yet. The objective of this work was to develop an elastic polymer for tissue engineering and drug delivery applications by using non-toxic, inexpensive and renewable monomers. A new nature-derived renewable material, xylitol, was used to synthesize an elastic polymer with the presence of a crosslinking agent, dodecanedioic acid. Here a simple melt condensation polymerization method was used to synthesize the poly(xylitoldodecanedioic acid)(PXDDA). The physicochemical and biological properties of the new PXDDA polymer were characterized. Fourier transform infrared (FTIR) confirmed the formation of ester bonding in the polymer structure, and thermal analysis demonstrated that the polymer was completely amorphous. The polymer shows high elasticity. Increasing the molar ratio of dodecanedioic acid resulted in higher hydrophobicity and lower glass transition temperature. Further, the polymer degradation and in vitro dye release studies revealed that the degradation and dye release from the polymer became slower when the amount of dodecanedioic acid in the composite increased. / Includes bibliography. / Dissertation (Ph.D.)--Florida Atlantic University, 2019. / FAU Electronic Theses and Dissertations Collection
148

Steigerung der Proliferationsfähigkeit primärer humaner Keratinozyten aus oraler Mukosa im Zellkultursystem durch Anreicherung von humanen epidermalen Stammzellen / Enhanced proliferation of oral mucosal keratinocytes by the use of enriched human epidermal stem cells in vitro

Dickhuth, Janike January 2013 (has links) (PDF)
Da Defekte im Bereich der oralen Schleimhaut infolge von Traumata, angeborenen sowie erworbenen Krankheiten die ungestörte Funktionsweise in Bezug auf Atmung, Nahrungsaufnahme und Sprache des Menschen empfindlich beeinträchtigen und ein adäquater, alle Funktionen wiederherstellender Wundverschluss mit dem limitierten Eigengewebe oft nicht möglich ist, bietet das Tissue Engineering durch die Entwicklung eines Hautäquivalents eine aussichtsreiche Alternative. Um eine ausreichende Menge an Zellen für die Herstellung eines autologen Transplantates in kurzer Zeit zur Verfügung zu stellen, sollte in der vorliegenden Arbeit eine Methode zur Steigerung der Proliferationsfähigkeit primärer humaner Keratinozyten aus oraler Mukosa im Zellkultursystem etabliert werden. Dazu mussten zunächst über die Explantation von Gewebeproben gesunder Patienten orale Schleimhautzellen gewonnen und die primären Keratinozyten von den mitwachsenden Fibroblasten isoliert werden. Dies wurde durch chemische und mechanische Separationsmethoden erreicht. Die Kultivierung der exprimierten Zellen erfolgte unter ständiger Beobachtung und physiologischen Bedingungen über einen Zeitraum von mehreren Wochen. Nach Konfluenz der zweiten Passage wurden die Zellen geerntet und für die Versuche vorbereitet. Die Steigerung der Proliferationsfähigkeit der Keratinozyten sollte durch die Anreicherung epidermaler Stammzellen erreicht werden, da diese insbesondere durch ihre Fähigkeit zur asymmetrischen Teilung die Grundlage für die Regeneration, Differenzierung und Homöostase des Gewebes bilden. Eine Möglichkeit zur Isolation von Zellen mit Stammzelleigenschaften stellt die Adhäsion an beschichteten Zellkulturgefäßen dar. Die Affinität des hauptsächlich in Stammzellen vorkommenden ß1­‐Integrin‐Rezeptors zu Bestandteilen der Basalmembran wie Kollagen­‐IV und Laminin sollte die Trennung hoch proliferativer Zellen von weniger teilungsaktiven Zellen leisten und das Protein indirekt als Marker für die Stammzellen fungieren. Über die Adhäsion der Keratinozyten an mit den Komponenten Kollagen‐IV und Laminin beschichteten Gefäßen ließen sich zwei Zellpopulationen (adhärente und nicht-adhärente Zellen) gewinnen. Unabhängig von der verwendeten Adhäsionskomponente zeigten die Fraktionen den charakteristischen Wachstumsverlauf (lag­‐Phase, log­‐ Phase, stationäre Phase und Absterbephase) in vitro kultivierter Zellen, allerdings konnte kein signifikanter Unterschied in Bezug auf die Vitalität und die Proliferationskinetik der Keratinozyten festgestellt werden. Eine nach der geleisteten Auftrennung der Keratinozyten zwischengeschaltete Analyse und Identifikation von Stammzellen mittels ß1­‐Integrin­‐Marker (z.B. durch einen Immunfluoreszenztest) könnte klären ob die adhärente Population überhaupt einen erhöhten Anteil an hoch proliferativen Keratinozyten beinhaltet oder ob die zahlreichen notwendigen, aber für die Zellen belastenden, Zwischenschritte der hier angewendeten indirekten Methode auslösend für die geringen Unterschiede sind. In Anlehnung an die von Stein et al. erarbeiteten guten Ergebnisse bezüglich der Proliferationskapazität oraler Keratinozyten nach Adhäsion an Kollagen­‐IV­‐beschichteten Zellkulturgefäßen wurde bei der vorliegenden Arbeit auf die aufwändige immunhistochemische Untersuchung verzichtet. Ein verstärktes Wachstum der adhärenten Population konnte nur bei vereinzelten Proben festgestellt werden; insgesamt konnte die prioritär gewünschte Steigerung der Proliferation primärer humaner Keratinozyten im Zellkultursystem zur raschen Bereitstellung von Zellen für die Entwicklung eines autologen Mundschleimhaut‐Transplantates nicht erreicht werden. Die drei angewandten Verfahren zur Erfassung der Quantität führten hinsichtlich der Wachstumssteigerung zu ähnlichen Ergebnissen. Da sie aber zum einen durch das Wegfallen der für die Zellzählung und den WST‐1‐Test notwendigen Zwischenschritte eine non­‐invasive (ohne mechanische Irritation und Interaktion mit Zusatzstoffen), d.h. für die Zellen schonende Methode darstellt und sich zum anderen die Ergebnisse der Real-Time-­Zellanalyse, im Gegensatz zur Endpunkt-­Messung, direkt auf die vorangegangenen Messungen beziehen, überzeugte die Auswertung mittels Impedanzmessung in Genauigkeit und Darstellung der Veränderung des Zellwachstums über die Zeit. / PURPOSE The limited availability of autogenous oral mucosa in oral and maxillofacial surgery for intraoral grafting after trauma or tumor resection can be balanced by the use of tissue engineered oral mucosa. The aim of this study was to evaluate conditions that lead to a rapid proliferation of vital and highly proliferative oral keratinocytes for application in tissue engineering. MATERIAL AND METHODS Human oral keratinocytes were obtained from oral mucosal specimens and cultivated. According to their affinity to β1-integrin, epidermal stem cells population were isolated using collagen type IV and laminin coated dishes. Cell proliferation and cell viability were measured using the CASY cell counter, WST-1 assays, and real-time cell analysis (xCELLigence). RESULTS Measurements on cell proliferation (CASY cell counter) and cell viability (WST-1 assay) showed the characteristic proliferation stages of in-vitro cultivated cells. No statistically significant differences could be monitored. Real-time cell analysis as a more direct and precise technique revealed a steeper growth curve of adherent cells and therefore generally higher proliferation kinetics compared to cells derived from the supernate. DISCUSSION Data from real-time cell analysis showed an increased proliferation of adherent cells compared to those derived from the supernate. These results demonstrate the increase of the proliferation capacity by cultivation of keratinocytes derived by adhesion to ECM proteins.
149

Stammzellbasierte Behandlungsstrategien zur Stimmlippenaugmentation und laryngealen Defektrekonstruktion / Stem cell-based treatment strategies for laryngoplasty and reconstruction of laryngeal defects

Ramos Tirado, Mario January 2015 (has links) (PDF)
Der Kehlkopf ist ein stimmerzeugendes knorpelhaltiges Organ und spielt eine wichtige Rolle in der Atemfunktion und beim aspirationsfreien Schluckakt. Funktionsstörungen des Kehlkopfs wie Stimmbandlähmungen werden durch Schädigungen des Kehlkopfnervs nach operativen Eingriffen und Halsverletzungen hervorgerufen. Des Weiteren führen durch Traumen, Teil- und komplette Resektionen verursachte Substanzdefekte des Kehlkopfs zu Funktionsverlusten. Die hierfür notwendigen und komplexen Rekonstruktionen werden durch das schlechte Regenerationspotential von Knorpelgewebe eingeschränkt und können nur bedingt durch synthetische Ersatzmaterialen oder körpereigenes Ersatzgewebe bewerkstelligt werden. Ist es möglich, mit Hilfe des Tissue Engineerings aus körpereigenen Stammzellen und biokompatiblen Trägermaterialien implantierbares Knorpelersatzgewebe herzustellen, welches zur dauerhaften Wiederherstellung der Kehlkopffunktionen eingesetzt werden kann? Die zusätzliche Markierung von Stammzellen mit superparamagnetischen Eisenoxidnanopartikeln (VSOP) als Zellmarker bietet die Möglichkeit der Detektion und der Verfolgung der Zellen mittels nicht-invasiver Nachweismethoden nach deren Implantation. Ist die Verwendung dieser Nanopartikel ohne negative Folgen für die Stammzellen möglich und sind diese für den Einsatz in der Laryngologie geeignet? Fettgewebsstammzellen (ASC) wurden aus humanem Liposuktionsmaterial und Kaninchen-Nackenfett isoliert und expandiert. Die Zellen wurden in Hydrogelkombinationen aus Kollagen Typ-I, Agarose, Fibrin und Hyaluronsäure eingebettet und mit den chondrogenen Wachstumsfaktoren TGF-β3, BMP-6 und IGF-I über 14 Tage differenziert. Anschließend wurden diese Zell-Hydrogelkonstrukte bezüglich Morphologie, extrazellulärer Matrixanreicherung und knorpelspezifischer Genexpression histologisch, immunhistochemisch und molekularbiologisch analysiert. In einem weiteren Schritt wurden die Integration der Zell-Hydrogelkonstrukte in natives Knorpelgewebe sowie die Defektdeckung in einem in vitro- und einem in vivo-Knorpeldefektmodell mit vor- und nicht-vordifferenzierten Zell-Hydrogelkonstrukten untersucht. Die Analyse möglicher zyto- und genotoxischer Effekte von VSOP sowie des Einflusses der Markierung von ASC mit VSOP auf die Proliferation, Migration und das Multidifferenzierungspotential erfolgte nach der Markierung der Zellen mit unterschiedlichen VSOP-Konzentrationen. Außerdem wurden VSOP-markierte ASC in Kaninchenstimmlippen injiziert und die Nachweisbarkeit dieser Zellen im Injektionsareal histologisch und mittels Magnetresonanztomographie (MRT) untersucht. Nach 14-tägiger chondrogener Differenzierung wurde in den Zell-Hydrogelkonstrukten eine knorpelähnliche Morphologie, die Anreicherung knorpelspezifischer Matrixproteine und die Expression chondrogener Markergene nachgewiesen. Die Kombination der chondrogenen Wachstumsfaktoren zeigte keinen verstärkenden Einfluss auf die Chondrogenese von ASC. Hydrogele aus Kollagen Typ I und Hyaluronsäure wiesen die stärkste extrazelluläre Matrixanreicherung auf. Bei den agarosefreien Hydrogelen war eine ausgeprägte Gelschrumpfung auffällig. In den beiden Knorpeldefektmodellen konnte weder eine Integration der Zell-Hydrogelkonstrukte in den Nativknorpel noch eine vollständige Defektdeckung nachgewiesen werden. Nach der Markierung von ASC mit VSOP zeigte sich bei der höchsten Konzentration von 1,5 mM eine genotoxische Wirkung. Zytotoxische Effekte sowie Einflüsse der Markierung auf die Proliferation, Migration und das Multidifferenzierungspotential von ASC waren nicht nachweisbar. VSOP-markierte ASC konnten nach deren Injektion in Kaninchenstimmlippen im Injektionsareal nur vereinzelt mittels MRT und histologisch nachgewiesen werden. Es ist möglich, mit Hilfe des Tissue Engineerings aus körpereigenen Stammzellen und biokompatiblen Trägermaterialien implantierbares knorpelähnliches Gewebe herzustellen. Dabei begünstigen agarosefreie Trägermaterialien die chondrogene Differenzierung von ASC. Diese könnte durch die jeweilige Erhöhung der Zelldichte und Wachstumsfaktorkonzentrationen sowie die Verlängerung der Induktionszeit verstärkt werden. Eine mögliche klinische Anwendung dieser knorpelähnlichen Gewebe in der Laryngologie ist jedoch durch deren Schrumpfung wie auch mangelnde Integration und Defektdeckung noch weit entfernt. Aufgrund ihrer genotoxischen Wirkung kann eine Verwendung von VSOP als Zellmarker auch unterhalb von 1,5 mM ohne negative Folgen für den Organismus nicht sicher ausgeschlossen werden. Der inhomogene Gewebekontrast im Kehlkopf, die schlechte Auflösung im MRT und die geringe Größe von VSOP erschweren die Nachweisbarkeit und Verfolgung markierter Zellen mittels MRT. Daher sind andere nicht-invasive Nachweismethoden für die Verwendung von VSOP im Kehlkopf zu evaluieren. Der möglichen Anwendung dieser knorpelähnlichen Gewebe und VSOP in der rekonstruktiven Laryngologie muss eine erfolgreiche Optimierung und ausführliche positive Validierung in klinischen Tests vorausgehen. / The larynx is a voice-producing and cartilage-containing organ that plays an important role in the respiratory function and aspiration-free swallowing. Dysfunctions of the larynx, such as vocal cord paralysis, are caused by damage to the laryngeal nerve after surgery and neck injuries. Furthermore, tissue defects caused by trauma and partial or complete resection of the larynx lead to loss of functions. The required and complex reconstructions are limited by the poor regeneration potential of cartilage, and can only be partially accomplished by synthetic graft materials or autologous replacement tissue. Is it possible to generate implantable cartilage replacement tissues that can be used for permanent restoration of laryngeal functions out of autologous stem cells and biocompatible scaffolds by the means of tissue engineering? The supplementary labeling of stem cells with very small superparamagnetic iron oxide nanoparticles (VSOP) as cell markers offers the possibility to identify and trace the cells after their implantation using non-invasive detection methods. Can VSOP be used without negative consequences for the stem cells, and are these nanoparticles suitable for application in laryngology? Adipose tissue-derived stem cells (ASC) were isolated from human liposuction material and rabbit nuchal fat. After expansion, the cells were embedded in hydrogel combinations of collagen type I, agarose, fibrin and hyaluronic acid and then differentiated with the chondrogenic growth factors TGF-β3, BMP-6, and IGF-I for 14 days. Subsequently, these cell-seeded hydrogel constructs were analyzed histologically, immunohistochemically and molecular biologically regarding morphology, extracellular matrix accumulation and cartilage-specific gene expression. In a further step, the integration of pre- and non predifferentiated cell-seeded hydrogel constructs into native cartilage tissue and defect coverage were examined in cartilage defect models in vitro and in vivo. The analysis of potential cytotoxic and genotoxic effects of VSOP, as well as the influence of the nanoparticles on proliferation, migration, and multilineage potential of ASC, was performed after labeling the cells with different VSOP concentrations. In addition, VSOP-labeled ASC were injected into rabbit vocal folds and the detectability of these cells in the injection area was examined histologically and by magnetic resonance imaging (MRI). A cartilage-like morphology, the accumulation of cartilage-specific matrix proteins and the expression of chondrogenic marker genes, was observed in the cell-seeded hydrogel constructs after 14 days of chondrogenic differentiation. The combination of the chondrogenic growth factors had no reinforcing effect on the chondrogenesis of ASC. Hydrogels of collagen type I and hyaluronic acid showed the strongest extracellular matrix accumulation. A pronounced shrinkage was observed with agarose-free hydrogels. In the cartilage defect models neither an integration of the cell-seeded hydrogel constructs into the native cartilage nor a complete defect coverage were detected. The labeling of ASC with the highest VSOP concentration of 1.5 mM induced genotoxic effects. Cytotoxic effects and influences of labeling with VSOP on proliferation, migration and multilineage potential of ASC could not be observed. After their injection into rabbit vocal folds VSOP-labeled ASC were only sporadically detected histologically and by MRI in the injection area. It is possible to generate implantable cartilage-like tissues out of autologous stem cells and biocompatible scaffolds by the means of tissue engineering. Here, agarose-free scaffolds promote the chondrogenic differentiation of ASC. This may be enhanced by increasing the cell density and growth factor concentrations as well as extending the induction time. Because of their shrinkage and the lack of integration and defect coverage, a possible clinical application of these cartilage-like tissues in laryngology is still far away. Due to the genotoxic effects of 1.5 mM VSOP, the use of these nanoparticles as cell markers without negative consequences for the organism cannot be ruled out with certainty at lower concentrations. The inhomogeneous tissue contrast in the larynx, a poor resolution in MRI and the small size of VSOP make labeled cells difficult to detect and trace in the larynx by MRI. Therefore, other non-invasive detection methods for the use of VSOP in the larynx have to be evaluated. The potential application of these cartilage-like tissues and VSOP in reconstructive laryngology must be preceded by successful optimization and extensive positive validation in clinical trials.
150

Die Herstellung von Scaffolds aus funktionellen Hybridpolymeren für die regenerative Medizin mittels Zwei-Photonen-Polymerisation / Fabrication of scaffolds of hybrid polymers for regenerative medicine using two photon polymerization

Stichel, Thomas Günther January 2014 (has links) (PDF)
In der vorliegenden Arbeit wurde das Verfahren der Zwei-Photonen-Polymerisation von anorganisch-organischen Hybridpolymeren (ORMOCER®e) untersucht. Untersuchungsschwerpunkte bildeten dabei die theoretischen Betrachtungen der Wechselwirkung zwischen Laser und Hybridpolymer, die experimentelle Charakterisierung unterschiedlicher ORMOCER®e sowie die Aufskalierung der Technologie im Hinblick auf die Herstellung von Scaffold-Strukturen für die regenerative Medizin. Hierbei wurde u. a. ein innovativer Belichtungsaufbau entworfen und aufgebaut, der es erlaubt makroskopische, poröse Scaffold-Strukturen mit minimalen Strukturgrößen im Bereich von wenigen Mikrometern herzustellen. ORMOCER®e sind typischerweise für optische Anwendungen konzipiert, weisen allerdings z. T. biokompatible Eigenschaften auf. Das Material ORMOCER® MB-47 wurde von M. Beyer eigens für biologische Anwendungen synthetisiert. Es zeichnet sich durch Biokompatibilität, teilweiser Biodegradierbarkeit und hervorragende Strukturierbarkeit durch die Zwei-Photonen-Polymerisation aus. Das in dieser Arbeit verwendete Mikrostrukturierungssystem beinhaltet im Wesentlichen einen Ultrakurzpulslaser, der 325 fs Pulse bei 1030 nm emittiert (verwendet wird die zweite Harmonische bei 515 nm), ein hochpräzises Positionierungssystem, bestehend aus drei luftgelagerten Lineartischen mit einer Reichweite von 10 cm (y-, z-Richtung) bzw. 15 cm (x-Richtung) sowie diversen Objektiven zur Fokussierung. Mit diesen Komponenten lassen sich komplexe dreidimensionale Strukturen mit minimalen Strukturgrößen von bis unter 100 nm erzeugen. In Kapitel 5.1 wurden theoretische Untersuchungen im Hinblick auf das Wechselwirkungsverhalten zwischen der fokalen Intensitätsverteilung und dem Materialsystem zur Bildung eines Voxels durchgeführt, wobei das technische Wechselwirkungsvolumen und das chemische Wechselwirkungsvolumen samt den reaktionskinetischen Abläufen separat betrachtet wurde. Das technische Wechselwirkungsvolumen beschreibt die Wechselwirkung zwischen der fokalen Intensitätsverteilung und dem Materialsystem im Rahmen eines Schwellwertprozesses, der es erlaubt Strukturdimensionen unterhalb des Beugungslimits zu realisieren. Die theoretischen Untersuchungen diesbezüglich ergaben, dass sphärische Aberrationen die fokale Intensitätsverteilung (Intensity-Point Spread Function (IPSF)) in Abhängigkeit der Belichtungskonfiguration z. T. sehr stark beeinflussen. Darüber hinaus wurde durch Betrachtung des Schwellwertverhaltens ein mathematischer Zusammenhang zwischen der IPSF und der Leistungsabhängigkeit der Charakteristik des technischen Wechselwirkungsvolumens geschaffen. Das chemische Wechselwirkungsvolumen beschreibt das tatsächliche Volumen der stattfindenden Polymerisationsreaktion. Dieses geht über das des technischen hinaus, was eine Folge von raumeinnehmendem Kettenwachstum im Rahmen von reaktionskinetischen Teilprozessen ist. Durch die Simulationen dieser reaktionskinetischen Abläufe wurde das leistungsabhängige, zeitliche Verhalten der Reaktionsteilnehmer (Radikale, Monomer, Photoinitiator) und des Vernetzungsgrades ermittelt. Die Simulation wurden für sehr kurze Belichtungszeiten (< 10 ms) auf der Basis von gekoppelten Differentialgleichungen nach Uppal & Shiakolas durchgeführt. Dabei wurde der Einfluss der Teilchendiffusion sowie der Temperaturentwicklung als gering erachtet und in den Berechnungen vernachlässigt. Die Simulationsergebnisse zeigen, dass eine geringe Belichtungszeit nicht unbedingt durch größere Laserleistungen ausgeglichen werden kann, um einen bestimmten Vernetzungsgrad zu erzielen. Vielmehr führt eine höhere Leistung zu einem raschen Verbrauch des Photoinitiators im Reaktionsvolumen und damit einem schnelleren Erliegen der Polymerisationsreaktion. Um dennoch hohe Vernetzungsgrade erzielen zu können, sind die Reaktionsgeschwindigkeitskoeffizienten der Propagation und der Terminierung k_P und k_T sowie eine ausreichende Photoinitiatorkonzentration von entscheidender Bedeutung. Je größer das Verhältnis k_P/k_T, desto höhere Vernetzungsgrade können auch bei kurzen Belichtungszeiten realisiert werden, wobei ein wesentlicher Teil der Polymerisation als Dunkelreaktion stattfindet. Diese Erkenntnis ist für die Aufskalierung der Technologie der Zwei-Photonen-Polymerisation von großer Bedeutung, welche mit einer Verkürzung der Belichtungszeiten einhergehen muss. Des Weiteren zeigen die Simulationen, dass das spatiale Konversionsprofil eines Voxels ein lokales Minimum im Zentrum aufweisen kann. Dieses Phänomen tritt dann auf, wenn aufgrund der applizierten Leistung, welche gemäß des Profils der IPSF im Zentrum am höchsten ist, der Photoinitiator im Zentrum rasch verbraucht wird. In Kapitel 5.2 wurde die Voxelbildung, das Vernetzungsverhalten sowie die mechanischen Eigenschaften belichteter ORMOCER®e bei unterschiedlichen Parametern und Materialsystemen experimentell untersucht. An Hand von Voxelfeldern wurden die Voxelgröße, das Aspektverhältnis und das Voxelvolumen bei unterschiedlichen Laserleistungen ermittelt. Die Ergebnisse wurden mit den berechneten technischen Wechselwirkungsvolumina verglichen, wobei die Differenz von tatsächlicher Voxelgröße und technischem Wechselwirkungsvolumen als eine weitere charakteristische Größe eingeführt wurde. Dabei zeigte sich, dass besonders die Voxellänge von der Länge des technischen Wechselwirkungsvolumens derart abweicht, dass dies nicht durch raumeinnehmendes Kettenwachstum im Rahmen der Reaktionskinetik erklärt werden kann. Mögliche Erklärungsansätze basieren hierbei auf Wechselwirkungseffekte zwischen Lichtfeld und Material. Beispielsweise könnten durch den nichtlinearen optischen Kerr-Effekt oder die Polymerisation selbst Brechzahlinhomogenitäten induziert werden, welche die Voxelbildung durch Selbstfokussierung beeinflussen. Der Unterschied der Voxelbreite, also das laterale chemische Voxelwachstum, zur Breite des technischen Wechselwirkungsvolumens wurde hingegen mit Hilfe der Reaktionskinetik erklärt. Dabei zeigte sich, dass dieser Unterschied sowohl vom Material selbst als auch von der Fokussieroptik abhängt. Des Weiteren wurde die Polymerisationsrate der unterschiedlichen Materialien aus der Auftragung des Voxelvolumens gegenüber der Laserleistung durch lineare Approximation bestimmt. Hierbei wurde festgestellt, dass die Materialsysteme z. T. erhebliche Unterschiede aufweisen. Als das Materialsystem mit der höchsten Polymerisationsrate hat sich das auf Acrylaten als vernetzbare Gruppen basierende OC-V in Kombination mit dem Irgacure® Oxe02 Photoinitiator herausgestellt. Aus diesem Grund wurde es für die Herstellung von makroskopischen Strukturen durch die Zwei-Photonen-Polymerisation bevorzugt verwendet. Die unterschiedlichen Materialien wurden ferner mit Hilfe der µ-Raman-Spektroskopie auf ihr Vernetzungsverhalten untersucht. Konkret wurden hierbei Linienfelder unter Variation der Scan-Geschwindigkeit und der Laserleistung mit Hilfe der 2PP hergestellt und vermessen. Die Vernetzungsgrade wurden semi-quantitativ aus den Spektren ermittelt. Insgesamt wurden Vernetzungsgrade im Bereich zwischen 40 % und 60 % gemessen, wobei mit OC-V und 2 Gew.-% Irgacure® Ox02 die höchsten Vernetzungsgrade erzielt wurden. Des Weiteren hat sich gezeigt, dass die Konversionsgrade für die jeweiligen Materialsysteme bei allen Scan-Geschwindigkeiten sich auf einem im Rahmen der Fehlergrenzen gleichem Niveau befinden. Damit kann der durch Simulationen theoretisch prognostizierte Abfall des Sättigungskonversionsgrades mit zunehmender Scan-Geschwindigkeit mit entsprechend variierenden Belichtungszeiten nicht als verifiziert angesehen werden. Die verschiedenen Materialsysteme wurden außerdem bezüglich ihrer mechanischen Eigenschaften charakterisiert. Zu diesem Zweck wurden zylindrische Formkörper unter verschiedenen Bedingungen (1PP, 2PP, verschiedene Photoinitiatorkonzentrationen) hergestellt und Druckfestigkeitsmessungen durchgeführt, sowie die Dichten und die Vernetzungsgrade aus den Formkörpern bestimmt. Insgesamt wurden Elastizitätsmodule im Bereich zwischen 0,40 und 1,37 GPa und Bruchfestigkeitswerte zwischen 117 bis 310 MPa ermittelt. Es konnte festgestellt werden, dass die Konzentration des Photoiniators das Vernetzungsverhalten und damit die mechanischen Eigenschaften der Formkörper stark beeinflusst. Während geringe Konzentrationen zu geringeren Vernetzungsgraden und niedrigen Elastizitätsmodulen führten, zeigten die Formkörper höherer Konzentration ein deutlich spröderes Verhalten mit höheren Vernetzungsgraden und Elastizitätsmodulen. Das höchste Elastizitätsmodul wurde an Hand von Formkörpern vermessen, welche aus OC-V mit 2 Gew.-% Irgacure® Ox02 hergestellt wurden. Darüber hinaus wurde festgestellt, dass sich die mechanischen Eigenschaften von durch 2PP hergestellten Formkörpern durch die applizierte Laserleistung beeinflussen lassen. Die Ursache hierfür ist, dass durch die Laserleistung die Voxelgröße und damit der Überlapp zwischen den Voxeln eingestellt werden kann. Im Bereich des Überlapps findet dann eine Doppelbelichtung des Materials statt, was zu höheren Vernetzungsgraden führen kann. Außerdem wurden durch die 2PP bei hinreichend großen Belichtungsleistungen auch Formkörper realisiert, welche höhere Elastizitätsmodule und Bruchfestigkeitswerte aufwiesen als Körper, welche durch UV-Belichtung hergestellt wurden. Die Aufskalierung der Zwei-Photonen-Technologie wurde in Kapitel 5.3 behandelt. Neben einer ausführlichen Diskussion zu den Herausforderungen diesbezüglich, wurden zwei Belichtungsstrategien zur Herstellung von makroskopischen Scaffold-Strukturen eingesetzt und optimiert. Hierbei ist insbesondere der Badaufbau hervorzuheben, der es erlaubte Strukturen von prinzipiell unbegrenzter Höhe mit Hilfe der Zwei-Photonen-Polymerisation herzustellen. Eine wesentliche Herausforderung der Aufskalierung der 2PP ist die Beschleunigung des Prozesses. Aus den Betrachtungen geht hervor, dass für eine gravierende Beschleunigung der 2PP-Strukturierung neben der Scan-Geschwindigkeit auch das Beschleunigungsvermögen des Positionierungssystems entscheidend ist. Des Weiteren sind auch Parallelisierungsmethoden mit z. B. diffraktiven optischen Elementen nötig, um ausreichende Prozessgeschwindigkeiten zu erzielen. Der Standardaufbau mit Luftobjektiven wurde dazu verwendet millimetergroße Strukturen mit hoher Qualität aus ORMOCER®en herzustellen. Auch wenn die maximale Strukturhöhe durch den Arbeitsabstand des Objektivs beschränkt ist, hat sich gezeigt, dass dieser Aufbau sich für die einfache Herstellung von millimetergroßen Test-Scaffold-Strukturen eignet, welche z. B. für Zellwachstumsversuche oder mechanische Belastungstest eingesetzt werden können. Das biodegradierbare MB-47 wurde hierbei ebenfalls erfolgreich eingesetzt und u. a. für die Herstellung von Drug-Delivery-Strukturen verwendet. Der Badaufbau, basierend auf einem Materialbad mit durchsichtigem Boden, einem darin befindlichen und in der Vertikalen (z-Richtung) beweglichen Substrathalter sowie einer Belichtung von unten durch eine sich in der Ebene bewegende Fokussieroptik, wurde verwendet um eine Freiheitsstatue mit 2 cm Höhe sowie millimetergroße Scaffold-Strukturen mit Porengrößen im Bereich von 40 bis 500 µm in ORMOCER-V zu realisieren. Weitere Strukturierungsresultate mit z. T. anwendungsbezogenem Hintergrund sind die Gehörknöchelchen des menschlichen Ohrs in Lebensgröße, ein Scaffold in Form eines Steigbügels des menschlichen Ohrs, Test-Scaffold-Strukturen für mechanische oder biologische Untersuchungen sowie Drug-Delivery Strukturen. Es wurden Bauraten von bis zu 10 mm^3/h erzielt. Bezüglich der Prozessgeschwindigkeit und Strukturhöhe wurde bei Weitem noch nicht das Potential des luftgelagerten Positioniersystems ausgeschöpft. Dafür bedarf es einer Gewichtsoptimierung des bestehenden Belichtungsaufbau, um höhere Beschleunigungswerte und Scan-Geschwindigkeiten realisieren zu können. Unter Annahme einer effektiven Gewichtsoptimierung und der damit verbundenen Erhöhung der Beschleunigung auf 10 m/s^2 könnte eine Baurate bei einer Scan-Geschwindigkeit von 225 mm/s und einem Slice- und Hatch-Abstand von 15 und 10 µm von etwa 60 mm^3/h erzielt werden. Im Rahmen der Aufskalierung wurde ebenfalls der experimentelle Einsatz von diffraktiven optischen Elementen zur Fokus-Multiplikation untersucht. Die Experimente wurden mit Hilfe eines Elements durchgeführt, welches eine 2 x 2 Punkte-Matrix neben der ungebeugten 0. Ordnung bereitstellt und Bestandteil eines experimentellen Setups war, welches aus Linsen, Blenden und einem Objektiv zur Fokussierung bestand. Mit Hilfe der erzeugten Spot-Matrix wurden zum einen simultan vier Drug-Delivery-Strukturen hergestellt und zum anderen einzelne Scaffold-Strukturen realisiert. In jedem Fall wurde eine Beschleunigung des Prozess bzw. eine Erhöhung der Polymerisationsrate um den Faktor 4 für die verwendeten Parameter erreicht. Bei der Herstellung der Scaffolds wurden zwei unterschiedliche Strategien verfolgt. Während zum einen die Periodizität der inneren Scaffold-Struktur auf die Fokusabstände angepasst und damit simultan vier aneinandergereihte Einheitszellen hergestellt wurden, konnte zum anderen auch demonstriert werden, dass durch die geschickte Bewegung der Fokusse eine ineinander verschobene Struktur möglich ist. Der Vorteil der letzteren Strategie ist, dass auf diese Weise eine komplette Schicht gescannt werden kann und damit hohe Scan-Geschwindigkeiten realisiert werden können. Die erzielten Bauraten waren dennoch nicht größer als die Bauraten, die mit einem einzelnen Spot im Rahmen des Standardaufbaus oder des Badaufbaus erreicht wurden. Hierfür bedarf es weiterer Optimierung der Parameter und des Setups. Transmittiert fokussiertes Licht eine Grenzfläche zweier Medien mit unterschiedlichen Brechungsindizes, dann tritt sphärische Aberration auf, welche sich durch die Verbreiterung des Fokus besonders in axiale Richtung bemerkbar macht. Da diese im Rahmen der verwendeten Belichtungsstrategien die Strukturierungsergebnisse nachweislich beeinträchtigen, wurden experimentelle Untersuchungen sowie Optimierungsroutinen diesbezüglich durchgeführt. Im Zusammenhang mit dem Standardaufbau wurde eine Leistungsanpassung während der Strukturierung vorgenommen. Auf diese Weise wurde erreicht, dass bei variabler Fokustiefe im Material die maximale Intensität trotz sphärischer Aberration konstant gehalten wurde, wodurch sich die strukturelle Homogenität der Scaffolds entlang der axialen Richtung (optische Achse) deutlich verbesserte. Des Weiteren wurde der Badaufbau dazu verwendet, die axiale Intensitätsverteilung in-situ für diskrete Fokustiefen unter der Verwendung eines Objektivs mit der NA von 0,60 abzubilden. Zu diesem Zweck wurde aus hergestellten Voxelfeldern eine Voxelfeldfunktion ermittelt und mit der axialen IPSF korreliert. Dabei wurde angenommen, dass sich das chemische Wechselwirkungsvolumen vernachlässigbar gering vom technischen Wechselwirkungsvolumen unterscheidet. Die experimentellen Ergebnisse zeigten deutlich die für sphärische Aberrationen typischen Nebenmaxima auf. Die Lage bzw. Abstände dieser entsprachen in guter Übereinstimmung den jeweiligen Simulationen. Schließlich wurde noch die sphärische Aberration durch den Korrekturring der Objektive für verschiedene Deckglasdicken korrigiert. Die resultierende IPSF wurde ebenfalls mit Hilfe des Badaufbaus abgebildet, wobei keinerlei Nebenmaxima gefunden werden konnten. Die Breite des Hauptmaximums konnte deutlich verringert werden. Zusammengefasst lässt sich sagen, dass im Rahmen dieser Arbeit erhebliche Fortschritte bei der Aufskalierung der 2PP zur Erzeugung von Scaffold-Strukturen für die regenerative Medizin erzielt wurden. Die erreichten Strukturdimensionen und die Bauraten übertreffen alle bis dato bekannten Ergebnisse. Dabei wurden auch durch theoretische Betrachtungen und experimentellen Methoden grundlegende Erkenntnisse über die Reaktionsdynamik der durch die Zwei-Photonen-Absorption initiierten Polymerisationsreaktion gewonnen. Nichtsdestotrotz sind einige Fragestellungen offen sowie Problematiken des Prozesses vorhanden, die für eine Realisierung von makroskopischen Scaffold-Strukturen gelöst werden müssen. So sind die realisierten Bauraten noch zu gering, um in angemessener Zeit makroskopische Scaffolds-Strukturen herzustellen, welche deutlich größer als 1 cm^3 sind. Aus diesem Grund müssen weitere Verbesserungen bezüglich der Scan-Geschwindigkeit sowie des Einsatzes von diffraktiven optischen Elementen zur Erhöhung der Polymerisationsrate erzielt werden. Da bei der Verwendung von Multi-Spot-Arrays, welche mit Hilfe gewöhnlicher diffraktiver optischer Elemente erzeugt wurden, die Realisierung von beliebigen und detaillierten äußeren Scaffold-Formen eingeschränkt ist, empfiehlt es sich den Einsatz von Spatial Light-Modulatoren zu verfolgen. Diese fungieren als dynamisch modulierbares DOE, mit dem einzelne Spots gezielt ein- und ausgeblendet und Spotabstände dynamisch variiert werden können. Schließlich ist es vorstellbar, den Spatial Light-Modulator mit dem Badaufbau zu kombinieren, um uneingeschränkte, große Strukturen in annehmbarer Zeit mit hochaufgelösten Details herstellen zu können. Dieses Vorgehen bedarf allerdings noch der tiefgreifenden Untersuchung der Potentiale des Spatial Light-Modulators. Darüber hinaus weisen die theoretischen und experimentellen Untersuchungen zur Reaktionskinetik darauf hin, dass die Voxelentstehung ein komplexer Prozess ist, der möglicherweise auch durch nichtlineare optische Wechselwirkungseffekte abseits der Zwei-Photonen-Absorption beeinflusst wird. Daher sind hier weitere Untersuchungen und Berechnungen zu empfehlen, um z. B. den Einfluss einer intensitätsabhängigen Brechzahl auf die Voxelbildung quantifizieren zu können. Entsprechende Ergebnisse könnten schließlich dazu dienen, dass im Rahmen dieser Arbeit entwickelte Modell zur Voxelbildung, welches auf der getrennten Betrachtung von technischen und chemischen Wechselwirkungsvolumen basiert, zu verbessern. Ein leistungsfähiges Modell, welches die Voxelbildung in Abhängigkeit des Materials und der Fokussieroptik präzise vorhersagen kann, wäre für das Erzielen optimaler Strukturierungsergebnissen ein Gewinn. / In this thesis, the two photon polymerization technique using ORMOCER®s was investigated thoroughly. The main aspects of matter were the theoretical investigations of the interaction between laser and polymer, the experimental characterization of the different ORMOCER®s, and the scale-up of the photon polymerization technique in order to fabricate scaffolds for the regenerative medicine. The latter was achieved by designing and building up an innovative exposure device[38] which enables the fabrication of scaffold structures with minimal structure sizes of a view microns. The experiments were done using UV sensitive anorganic-organic hybrid polymers, also known as ORMOCER®s. These are typically synthesized for optical applications, but some are also biocompatible. The ORMOCER® MB-47 was invented by M. Beyer for biological application and possesses biocompatibility, partial biodegradability, and advanced 2PP structuring behavior. The micro-structuring system used contains an ultra-short pulse laser which emits 325 fs pulses at 1030 nm (applied was 515 nm using second harmonic generation), a highly precise positioning system which consists of three air-bearing stages with a travel range of 10 cm (y, z direction) and 15 cm (x direction), respectively, and some objectives for focusing. With these components, complex three-dimensional structures with minimal structure size below 1 µm can be produced. In Capital 5.1, theoretical studies of the interaction between the focal intensity distribution and the material, which defines voxel growth, were performed. Therefore, the technical interaction volume and the chemical interaction volume were separately investigated. The technical interaction volume describes the threshold driven interaction between the focal intensity distribution and the material system, which allows the realization of structure sizes below the resolution limit (diffraction) of the wavelength used. The theoretical investigations showed that spherical aberration influences the focal intensity distributions (Intensity-Point Spread Function (IPSF)) which were calculated for different experimental exposure configuration. The results propose a severe influence with increasing focus depth into the material. Moreover, a formal relation between the IPSF and the technical interaction volume was derived by using the threshold assumption. By using the Gaussian beam assumption as IPSF, the analogy of the derived formula to the voxel growth model of Serbin et al. was recognized. The chemical interaction volume represents the actual volume of the polymerization reaction. Its amount exceeds the technical interaction volume due to the space-consuming chain growth during the polymerization. By the simulation of the reaction kinetics of the polymerization, the time- and power-depending behavior of the different reactants (radicals, monomer, photo initiator) as well as the degree of conversion was calculated. The simulations were done for very short exposure times (< 10 ms) by using a system of coupled differential equations which are based on a model invented by Uppal & Shiakolas. Therefore, the influence of diffusion and temperature was estimated to be small on short time scales and thus neglected. The results of the simulations show that a short exposure time cannot be necessarily compensated by high laser powers to achieve a certain degree of conversion. Higher laser power leads rather to a swift consumption of the photo initiator and thus to a disruption of the polymerization. In order to achieve high degrees of conversions, the reactive rate coefficients of the propagation and termination k_P and k_T as well as a sufficient amount of photo initiator concentration is essential. The larger the ratio k_P/k_T the higher degree of conversion can be realized even with short exposure times whereas a significant part of the reaction takes place during the dark period. This finding is important for the scale-up of the photon polymerization technique which has to involve shorter exposure times. Moreover, the simulations show that the spatial profile of the degree of conversion can feature a central minimum. This phenomenon occurs when the central maximum intensity of the IPSF consumes the entire photo initiators in short times which leads to a disruption of the polymerization. In Capital 5.2, the voxel growth, the behavior of conversion as well as the mechanical properties of hardened ORMOCER®s were experimentally investigated with different parameters and material systems. By means of voxel fields, voxel sizes, aspect ratios and voxel volumes at different laser powers were determined. The results were compared with the calculated technical interaction volume, whereas the difference was invented as a new characteristic value. It has been shown that the voxel length deviates clearly from the length of the technical interaction volume which cannot be explained by space-consuming chain growth during the polymerization. Instead, it was assumed that this observation is reasoned by interaction effects between light and material (optical Kerr effect, polymerization) leading to an inhomogeneous refractive index distribution and thus to self-focusing and self-trapping. In contrast to that, the difference between the voxel diameter and the diameter of the technical interaction volume was correlated with reaction kinetic influences. Additionally, the dependency of the voxel volume on the laser power was linear approximated in order to determine the polymerization rate of different material systems. Here, strong differences between the materials were identified. The material with the highest polymerization rate was OC-V with the Irgacure® Oxe02 photo initiator which consists of acrylates as cross-linkable group. Because of this, this material system was preferred for 2PP structuring of large scale structures. The different materials were investigated concerning their conversion behavior by means of µ-Raman spectroscopy. Therefore, fields of lines were produced by 2PP with varying scan speed and laser power and measured. The degree of conversion was then semi-quantitative extracted from the spectra. All in all, the degrees of conversion were determined to be in the range of 40 to 60 % for all materials. The material with the highest degree of conversion was the OC-V with 2 wt.-% Irgacure® Ox02. Moreover, the measurements showed that the degree of conversion for each material system does not vary with the scan speed (exposure time) within the limits of measurement error. Thus, the simulations from Capital 5.1.3, which predicted that shorter exposure times cannot be necessarily compensated by higher laser powers, could not be confirmed. Furthermore, the mechanical properties of the different materials were characterized. Therefore, cylindrical samples were produced with different processes and parameters and tested with a compressive load. Also the densities and degrees of conversion were determined. All in all, elastic moduli between 0,40 and 1,37 GPa and load failures between 117 and 310 MPa were measured. It was detected that the photo initiator concentration influences the conversion behavior and thus the mechanical properties of the samples. While low concentrations led to lower degrees of conversion and lower elastic moduli, the samples produced with higher concentrations were more brittle with higher degrees of conversion and elastic moduli. The highest elastic modulus was measured for samples which were produced in OC-V with 2 wt.-% Irgacure® Ox02. Moreover, the mechanical properties of samples produced with 2PP can be influenced by the utilized laser power. This is reasoned by the voxel sizes which can be adjusted by the laser power and which determine the overlap of vicinal voxels at distinct hatch and slice distances. In the overlap area double exposure takes place which can lead to higher degrees of conversion. It was found that with sufficient laser powers the 2PP leads to higher elastic moduli and load failures than the 1PP. Capital 5.3 deals with the scale-up of the photon polymerization technique. After the discussion of the challenges, two exposure strategies were used to produce macroscopic scaffold structures. Especially, the vat setup has to be emphasized which can be used to build structures with basically unlimited structure heights by means of the 2PP technique. One of the major challenges concerning the scale-up of the 2PP is the speed-up of the process. Therefore, the scan speeds as well as the acceleration of the positioning system play important roles. Moreover it was detected that further parallelizing techniques as the utilization of diffraction optical elements are needed in order to achieve a sufficient speed-up of the 2PP technology. The standard exposure setup with air objectives was used to fabricate millimeter-sized structures in ORMOCER®s which high quality. Though the maximal achievable structure height is limited by the working distance of the objective used, the setup is suitable for the fabrication of macroscopic scaffolds which can be utilized for biological or mechanical testing. Moreover, the biodegradable MB-47 was successfully used for the fabrication of Drug Delivery structures. The vat setup bases on a vat/bath as material reservoir with transparent bottom, a sample holder moveable in the vertical (z) direction, and an upside down x-y-scanning objective. The sample can be moved upwards which enables one to build structures whose heights are not limited by the working distance of the employed objective anymore. This setup was used to fabricate a model of the statue of liberty with a height of 2 cm and millimeter-sized scaffolds with pore sizes in the area between 40 and 500 µm in ORMOCER®-V. Moreover, the human ossicles in life size, a scaffold in the shape of the human stapes, different test scaffold structures for mechanical and biological investigations and drug delivery structures were build. The achieved maximum building rate was 10 mm^3/h. So far, the speed-up and scale-up potentials of the air-bearing positioning system haven’t been exhausted when using the vat setup. Therefore, the setup has to be optimized regarding weight and stability in order to realize higher accelerations of up to 10 m/s^2. This would enable build rates of up to 60 mm3/h with a scan speed of 224 mm/s and slice and hatch distances of 15 and 10 µm. Moreover, the speed-up by means of diffractive optical elements was experimentally investigated. Therefore, an optical setup was constructed which includes the diffractive optical element, some lenses, an objective, and a blind to blank the zero order. By this a 2 x 2 spot matrix was generated which was used for the simultaneous fabrication of four drug delivery structures and the production of single scaffold structures. In both cases an increase of the polymerization rate was achieved regarding to structuring without diffractive optical elements. For the fabrication of the scaffold structures two different scan strategies were performed. Using the first one, a scaffold was built up by the simultaneous structuring of four scaffolds’ gyroid unit cells. After finishing these cells, more cells were stitched to them until a millimeter-sized scaffold was achieved. For this strategy, it’s important that the size of the unit cell design is adjusted to the focal matrix distances. With the second strategy a scanning of the whole spot matrix along the whole scaffold flank is performed. By this it was possible to produce a pile of interleaved beams which represents a woodpile-like scaffold. The fact that the produce lines of each layer are as long as scaffold flank leads to the advantage that higher scan speeds and thus build rates can be achieved than with the first strategy. Nevertheless, the realized maximum build rates weren’t exceeding the build rates which were reached by using the standard setup or the vat setup. Thus, more optimization of parameters and setup is needed. If focused laser lights transmits through an interface of two materials with different refractive indices, spherical aberration occurs which leads to blurring of the focal intensity distribution especially in the axial direction. When using air objectives this blurring affects the structuring results. Hence theoretical and experimental investigations were done in order to optimize exposure routines. When using the standard exposure setup, power adoption was performed during the structuring process which allows holding the maximum focal intensity constant at varying focal depths in the presence of spherical aberration influences. By this, a clear improvement of the scaffolds’ quality and homogeneity along the axial direction was achieved. Furthermore, the vat setup with the NA 0.60 objective was used to perform an experimental in situ mapping of the focal axial intensity distribution for different focal depths. A voxel field function was extracted from produced voxel fields and correlated with the axial intensity distribution. Therefore, it was assumed that the chemical interaction volume is equal to the technical interaction volume. The experimental results showed clearly the presence of side maxima which are typical for spherical aberration influences. The distances between them were predicted quite exactly by theoretical simulations. Finally, the spherical aberrations were reduced by the correction collar of the objective. The resulting intensity distribution was also mapped with the vat setup and no side maxima were found for the experimental intensity distribution. Moreover the contrast of the main maximum was clearly improved. Overall, it can be concluded that within this work a noticeable progress in the scale-up of the two-photon polymerization technique was achieved which is important for the fabrication of scaffold structures for the regenerative medicine. The realized structure dimensions and build rates exceed all, so far, known specifications of structures fabricated by two-photon polymerization. Moreover, basic knowledge of the most important aspects of the scale-up was discovered by thoroughly theoretical and experimental investigations. Nevertheless, there is still much improvement necessary to establish the two photon polymerization technique as a competitive tool for the production of scaffold structures which are larger than 1 cm^3. Higher scan speeds and advanced setups with diffractive optical elements must be applied to achieve build rates in the range over 1 cm^3/h. Due to the lack in flexibility of usual diffractive optical elements, it is recommended to use spatial light modulators which are dynamic adjustable diffractive optical elements. With them it is possible to vary the spot intensity distribution, spot number as well as the spot distances during the process. Finally, it is imaginable that in future the vat setup combined with a spatial light modulator can be used for the fabrication of large macro structures with finest details in adequate time. But therefore, it is necessary to perform thoroughly investigations concerning the potentials of spatial light modulators. Moreover, the theoretical and experimental investigations on the reaction kinetics show that voxel growth is a complex process which is possibly affected by nonlinear optical interactions aside from the two-photon absorption phenomenon. Thus, intensive study should be done in order to, for example, quantify the influence of an intensity-dependent refractive index on the voxel growth. Maybe, results could be used to improve the voxel growth model of this work which bases on the separate consideration of the technical and chemical interaction volumes. A powerful tool enabling the prices prediction of voxel growth characteristics depending on material and focusing optics would help to improve the detail quality of fabricated scaffolds.

Page generated in 0.0672 seconds