• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement, modélisation et caractérisation d'une maille innovante réalisée en fabrication additive pour les grands défauts osseux / Conception, modelisation and simulation of a 3D printed bone substitute for maxillofacial surgery

Adam, Jérémy 13 December 2017 (has links)
Ce travail de thèse traite du développement d’une maille en titane imprimée en 3D pour le comblement des grands défauts osseux. La perte de substance osseuse intervient lors de traumatismes importants ou de chirurgies ablatives (dues à des infections ou à des cancers). Lorsque le défaut atteint un stade critique, la régénération osseuse est impossible et on assiste à une perte de fonction. Il faut alors recourir à des chirurgies reconstructrices comme par exemple la reconstruction mandibulaire. Aujourd’hui, la chirurgie communément pratiquée pour reconstruire la mandibule est la reconstruction par lambeaux libres de fibula, laquelle demande un investissement en temps et en ressource colossale pour des résultats mitigés avoisinant les 10% de taux d’échec. En nous basant sur la littérature internationale, nous avons développé une maille en titane imprimée en 3D pour remplacer l’autogreffe de fibula et ainsi limiter les effets secondaires liés au site donneur tout en offrant aux cellules mésenchymateuses des conditions optimales à la colonisation osseuse. D’un point de vue mécanique, cela consiste à abaisser la rigidité native du titane (110GPa) à une rigidité comprise entre 0,1 et 1 GPa. Pour réaliser cette maille, nous avons mis en place une méthodologie de design qui nous a permis d’innover en mettant au point un système de reprise de charge. Ce système de reprise de charge permet d’adapter la réponse de l’implant en fonction de l’intensité de la sollicitation, ce qui permet de combiner une rigidité faible et une résistance à l’effort élevée. Les différentes itérations de design ont été testées par éléments finis, jusqu’au motif final, lequel a été caractérisée lors de tests mécaniques réels en compression, en traction et en flexion. Remplissant la majorité du cahier des charges, nous avons ensuite mis au point une étude animale, laquelle sera réalisée ultérieurement. Enfin, cette étude a permis de mettre en évidence certaines limitations de l’impression 3D métallique, principalement liés aux surfaces non supportées que nécessitent la reprise de charge. Cette maille très prometteuse est aujourd’hui en cours d’optimisation pour permettre d’être rapidement mise à la disposition des patients. / The work detailed in this thesis is about a titanium 3D printed mesh for large bone defects. Large bone defects are often due to surgical resections, performed after a cancer or an infection. When the defect reach a critical size, bone regeneration is impossible and it often leads to the loss of function. When it happened, the wound need to be cured using reconstructive surgery. The mandibular reconstruction is one of the most performed reconstructive surgery. Nowadays, we reconstruct the mandible with the fibula free flap technique, which require huge amount of time and resources for mixed results (around 10% failure rate). Based on the international literature, we developed a titanium 3D printed mesh to replace the fibula autograft and limit its side effect while offering to mesenchymal cells optimal growing environment. On the mechanical point of view, this environment requires to decrease the titanium initial rigidity from 110GPa to a range between 0.1 and 1GPa. In order to achieve that goal, we have developed a design methodology that lead us to innovation. We developed a load restauration system that allow us to combine low rigidity and high resistance. In order to find the final design, we used finite element modeling. Then, the final design have been tested mechanically in compression, traction and flexion. Because most of the requirements were reached, we designed an animal study which should take place in the next years. Eventually, we discovered some limitation for metallic 3D printing, essentially due to unsupported areas required for the load restauration. This innovative mesh is today optimized in order to be rapidly given to patients in the need.
2

Analyses expérimentales et modélisation numérique de l'ostéogenèse au sein d'un implant poreux en titane. / Experimental analysis and numerical model of osteogenesis within a porous titanium scaffold

Schmitt, Mary 16 June 2015 (has links)
Récemment, dans le domaine de la reconstruction tissulaire, des substituts osseux ou scaffold, ont été utilisés comme alternative aux autogreffes. La complexité de l'ostéogenèse au sein d'une structure poreuse rend son observation expérimentale difficile et par conséquent le développement et l'optimisation des scaffolds sont loin d'être achevés. En complément d'expérimentations animales, il est donc nécessaire de développer des modèles numériques afin de mieux comprendre ce processus. L'objectif de ce travail était de développer un modèle numérique capable de reproduire l'ostéogenèse au sein d'un scaffold poreux en titane, implanté sur la partie non dentée d'une hémimandibule de brebis durant 12 semaines. Cette thèse était donc basée sur une approche à la fois expérimentale et numérique, ce qui constituait l'élément clé du projet. En effet, la plupart des modèles existants n'ont pas été validés expérimentalement ou l'ont été à l'aide d'expérimentations réalisées sur de petits animaux (i.e. lapin, rat) puisque leur taille et leur coût facilitaient le protocole. Néanmoins, contrairement au mouton, leurs processus de régénération osseuse sont très éloignés de celui de l'homme. L'étude a été organisée en trois tâches. Tout d'abord, les expérimentations animales ont été réalisées en collaboration avec le Dr Thomas Schouman (Hôpital de la Pitié-Salpêtrière), et OBL, une PME française fabriquant les scaffolds en titane. Puis, un modèle numérique en éléments finis décrivant l'activité cellulaire au sein du scaffold durant les 12 semaines d'implantation a été conçu. Enfin, des examens histologiques et micro-tomographiques et des tests mécaniques réalisés sur chaque hémimandibule explantée ont permis de: i) quantifier le pouvoir ostéo-conducteur du scaffold en titane et ii) valider le modèle numérique d'ostéogénèse. / Recently, in the tissue reconstruction field, bone substitutes or scaffolds have been used as an alternative to autograft. The complexity of osteogenesis within a scaffold makes its experimental observation difficult and the development and optimization of scaffolds are thus far from being complete. In addition to animal experiments, it is then necessary to develop numerical models to better understand such process. The objective of this work was to develop a numerical model able to reproduce osteogenesis within a porous titanium scaffold implanted on the non-toothed part of a ewe hemimandible for 12 weeks. Therefore, this thesis was based on both an experimental and a numerical approach, which constituted the key element of the project. Indeed, most of the existing models have not been validated or have been validated using experiments performed on small animals (i.e. rabbit, rat) since their size and cost make the protocol easier. Nevertheless, unlike the sheep, their bone regeneration process is quite different from human's. The study was organized into three tasks. First, animal experiments were carried out in collaboration with Dr. Thomas Schouman (Pitié-Salpêtrière hospital) and OBL, a french company manufacturing the porous titanium scaffolds. Then, a numerical model describing cellular activity within the scaffold during the 12 weeks of implantation was developed. Finally, histological and micro-tomographic analyses and mechanical tests performed on each hemimandible have enabled to: i) quantify the osteoconductive potential of the scaffold and ii) validate the numerical results.
3

Le larynx artificiel : de l'in vitro à la première implantation clinique / Laryngeal replacement after total laryngectomy

Dupret Bories, Agnès 30 September 2013 (has links)
Objectifs : Ce travail a pour but de développer un larynx artificiel composé de 2 structures : 1) une structure inamovible en titane poreux prolongeant la trachée; 2) une double valve remplissant la fonction de sphincter. Matériels et Méthodes : L’intégration de la prothèse en remplacement trachéal a été testée in vitro et in vivo sur les modèles animaux rats, lapins et brebis. Suite à l’ensemble de ces résultats, nous avons réalisé la première application clinique du larynx artificiel. Résultats : 1) L’ajout d’un tube de silicone endoprothétique améliore la survie chez le gros animal; 2) l’intégration tissulaire de la prothèse de trachée associée à un matériel polymérique biodégradable était supérieure à celle des prothèses en titane poreux nu; 3) la vitesse de colonisation des prothèses en titane poreux était accélérée lorsque l’on diminuait la taille des billes. Un premier patient a été implanté avec une prothèse de larynx artificiel avec des résultats satisfaisants à 9 mois. Conclusions : Nos études concernant l’intégration de prothèses de trachées in vitro et in vivo ont permis de contribuer à l’aboutissement de la première application clinique de larynx artificiel. / Background: The aim of this work is the design of an artificial larynx made of 2 elements: 1) a non-removable bio-integrable structure designed to provide a connection with the remaining trachea; 2) a double valve that fulfills the sphincter function. Materials and Methods: In vitro and in vivo tests (rat, rabbit and sheep model) were performed to achieve the tracheal prosthesis integration. Following all these results, we carried out the first clinical application of an artificial larynx. Results: i) The long-term survival of the animals was improved when an endoprosthetic silicon calibration tube was used; ii) tissue integration of the prostheses in porous titanium filled with biodegradable polymer was better than the bare porous titanium; iii) prosthesis integration was improved when pore size was decreased. A first patient was implanted with an artificial functional larynx with satisfactory results after 9 months of implantation. Conclusion: The whole in vivo and in vitro studies concerning the integration of the tracheal prosthesis has contributed to the success of the first clinical application of the artificial larynx.
4

Étude des relations entre les propriétés physicochimiques et photocatalytiques de revêtements nanostructurés de dioxyde de titane synthétisés par pulvérisation cathodique magnétron en condition réactive / A study of physico-chemical and photocatalytic properties relationships of nanostructured coatings of titania synthesized by reactive magnetron sputtering

Aubry, Éric 14 December 2007 (has links)
La photocatalyse est une technique émergente de traitement des déchets qui nécessite un faible apport d’énergie présentée sous forme lumineuse. L’emploi de catalyseurs supportés autorise une séparation efficace des produits de réaction, en dépit d’une réduction de leur surface spécifique. De par les avantages qu’offre la pulvérisation réactive (bonne tenue mécanique, synthèse sur substrats froids, contrôle aisé de la microstructure, …), la synthèse de revêtements de TiO2 par cette technique fait l’objet de recherches intensives.Après une description des mécanismes mis en jeu lors d’une réaction photocatalytique, les phénomènes physiques à la base de la synthèse de revêtements céramiques par pulvérisation réactive à haute pression sont détaillés. Afin de s’affranchir de la contamination du catalyseur par le sodium du verre, une barrière de diffusion de SiNx est intercalée. Les influences de la position du substrat par rapport au flux de vapeur métallique, de la température de recuit, de la pression totale et de l’épaisseur des films catalyseurs sur leurs propriétés physicochimiques et photocatalytiques sont étudiées, autorisant la formulation d’hypothèses quant aux liens qui les unissent. Enfin, des premiers travaux portant sur la synthèse d’un photocatalyseur TiO2-xNy cristallisé in situ à haute pression sont présentés. / AThe photocatalysis is a new way of organic pollutants treatments which needs a low energy supplied under light wave. The use of supported catalyst allows an efficient separation of the reaction products, in spite of their specific area reduction. Owing to the advantages that offers reactive sputtering (good mechanical adhesion, synthesis on cold substrates, easy control of the microstructure, …), the synthesis by this technique of the most promising semiconductor photocatalyst, namely the titanium dioxide, is the subject of intensive researchs. After a description of the mechanisms occurring during a photocatalytic reaction, the physical phenomena at the origin of the ceramic coating synthesis are detailed. In order to hinder the sodium contamination of the catalyst from the glass substrate, a SiNx diffusion barrier is intercalated. The influences of the substrate position relatively to the metallic flux, the annealing temperature, the total pressure and the TiO2 coating thickness on the physico-chemical and photocatalytic properties are investigated allowing the formulation of hypothetic relations combining them. Finally, first studies on in situ crystallized TiO2-xNy photocatalyst deposited at high pressure are presented.
5

Le larynx artificiel : de l'in vitro à la première implantation clinique

Bories, Agnès 30 September 2013 (has links) (PDF)
Objectifs : Ce travail a pour but de développer un larynx artificiel composé de 2 structures : 1) une structure inamovible en titane poreux prolongeant la trachée; 2) une double valve remplissant la fonction de sphincter. Matériels et Méthodes : L'intégration de la prothèse en remplacement trachéal a été testée in vitro et in vivo sur les modèles animaux rats, lapins et brebis. Suite à l'ensemble de ces résultats, nous avons réalisé la première application clinique du larynx artificiel. Résultats : 1) L'ajout d'un tube de silicone endoprothétique améliore la survie chez le gros animal; 2) l'intégration tissulaire de la prothèse de trachée associée à un matériel polymérique biodégradable était supérieure à celle des prothèses en titane poreux nu; 3) la vitesse de colonisation des prothèses en titane poreux était accélérée lorsque l'on diminuait la taille des billes. Un premier patient a été implanté avec une prothèse de larynx artificiel avec des résultats satisfaisants à 9 mois. Conclusions : Nos études concernant l'intégration de prothèses de trachées in vitro et in vivo ont permis de contribuer à l'aboutissement de la première application clinique de larynx artificiel.

Page generated in 0.0431 seconds