• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1151
  • 12
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1192
  • 1192
  • 830
  • 756
  • 358
  • 352
  • 341
  • 310
  • 298
  • 231
  • 199
  • 154
  • 152
  • 143
  • 136
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Aplicação da tomografia computadorizada industrial na análise de rochas / HE INDUSTRIAL COMPUTERIZED TOMOGRAPHY APPLIED ON THE ROCK ANALYSIS

Guaraciaba de Campos Tetzner 22 December 2008 (has links)
Este trabalho consiste no estudo das possibilidades de aplicações técnicas de Tomografia Computadorizada (TC) utilizando-se um equipamento desenvolvido no Centro de Tecnologia das Radiações (CTR), do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP). O equipamento é formado por uma fonte de radiação gama (60Co), um detector de cintilação de iodeto de sódio dopado com Tálio, NaI(Tl), um sistema mecânico para movimentação (rotação e translação) do objeto e o sistema computacional. Todo este sistema operacional foi elaborado e desenvolvido pela equipe de TC do CTR-IPEN-CNEN/SP e seus colaboradores usando recursos e tecnologia nacional. O primeiro teste de validação do equipamento foi feito com uma amostra cilíndrica de polipropileno (fantoma) com duas cavidades (orifícios) cilíndricas de 5x25 cm (diâmetro e comprimento). Nos testes, estes orifícios foram preenchidos com materiais de densidades diferentes (ar, óleo e metal) cujos coeficientes de atenuação são conhecidos. O objetivo deste teste foi avaliar a qualidade de resposta do equipamento. Neste trabalho apresenta-se o estudo comparativo entre o equipamento de tomografia computadorizada do CTR-IPEN-CNEN/SP que utilizou uma fonte de radiação gama (60Co) e outro equipamento disponibilizado pelo Departamento de Geociências da Universidade do Texas (CTUT), o qual utilizou nos testes uma fonte de raios X (450 kV e 3,2 mA). Como resultado, as imagens obtidas e o estudo da abrangente utilidade do equipamento aqui desenvolvido reforçaram a proposta de que o desenvolvimento da tomografia computadorizada industrial constitui um passo importante na pesquisa e desenvolvimento da tecnologia nacional. / This work is a study of the possibilities of the technical applications of Computerized Tomography (CT) by using a device developed in the Radiation Technology Center (CTR), Institute for Energy and Nuclear Research (IPEN-CNEN/SP). The equipment consists of a gamma radiation source (60Co), a scintillation detector of sodium iodide doped with thallium (NaI (Tl)), a mechanical system to move the object (rotation and translation) and a computer system. This operating system has been designed and developed by the CTR-IPEN-CNEN/SP team using national resources and technology. The first validation test of the equipment was carried out using a cylindrical sample of polypropylene (phantom) with two cylindrical cavities (holes) of 5x25 cm (diameter and length). In these tests, the holes were filled with materials of different density (air, oil and metal), whose attenuation coefficients are well known. The goal of this first test was to assess the response quality of the equipment. The present report is a study comparing computerized tomography equipment CTR-IPEN-CNEN/SP which uses a source of gamma radiation (60Co) and other equipment provided by the Department of Geosciences in the University of Texas (CTUT), which uses an X-ray source (450 kV and 3.2 mA). As a result, the images obtained and the comprehensive study of the usefulness of the equipment developed here strengthened the proposition that the development of industrial computerized tomography is an important step toward consolidating the national technology.
72

Estimativa de dose efetiva de radiação recebida por pacientes submetidos a exames de tomografia computadorizada e proposta para registro de dose por paciente em sistema de informação de radiologia / Effective dose estimate received by patients undergoing computed tomography scans and proposal to dose record per patient in a radiology information system

Correia, Paula Duarte 21 November 2016 (has links)
A necessidade de estimar a dose efetiva de radiação recebida pelos pacientes em exames de tomografia computadorizada (TC) é muito discutida atualmente devido ao fato de que este exame está entre aqueles que mais depositam dose em pacientes submetidos a exames radiológicos. O objetivo deste trabalho foi implementar um método de estimativa de dose efetiva em exames de TC baseado em evidências bem estabelecidas e em informações contidas nas imagens. Após dosimetria realizada no equipamento de TC, mapeamento dos protocolos e definição dos fatores de correção a serem utilizados, uma rotina de processamento dos dados foi criada para conversão da informação do cabeçalho DICOM da imagem radiológica em dose efetiva estimada, de modo que as informações levantadas poderão ser disponibilizadas, em registro no sistema de informação de radiologia do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo - HCFMRP/USP, aos médicos e profissionais de saúde envolvidos. / Computed tomography scan is the procedure that most deposits radiation dose in patients undergoing radiologic examinations. That is the reason why the need to record the dose received is currently discussed. The aim of this study was to implement an method to estimate effective dose received in CT scans based on well-established evidences and information contained in images. After performing dosimetry in CT equipment, mapped protocols and define correction factors, a data processing routine was created for conversion of DICOM header information in estimated effective dose, so that the information raised could be avalable in Hospital\'s radiology information system for doctors and health professionals involved.
73

Avaliação da sensibilidade entre a radiografia digital periapical direta e a tomografia computadorizada de feixe cônico, no diagnóstico de reabsorções radiculares simuladas em ex-vivo

Borges, Marco Aurélio Gagliardi [UNESP] 23 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-23Bitstream added on 2014-06-13T19:20:41Z : No. of bitstreams: 1 000737820.pdf: 887635 bytes, checksum: 59f6ba12378e532f7e352af49bf00dc2 (MD5) / O objetivo deste trabalho e de comparar a radiografia digital com a tomografia computadorizada de feixe cônico e a tomografia computadorizada helicoidal multislice no diagnóstico de reabsorções radiculares. Foram utilizadas 25 mandíbulas suínas, com 90 simulações de reabsorções realizadas com fresas de número ¼, ½ e 1 distribuídas uniformemente pelos três terços. Após a realização dos exames radiográficos e tomográficos, as imagens foram analisadas por três examinadores. Obtivermos como resultado que a Tomografia computadorizada de feixe cônico identificou 85,18%, a tomografia computadorizada helicoidal multislice identificou 87,77% e a radiografia digital identificou apenas 45,92% das reabsorções. Concluímos que a tomografia computadorizada de feixe cônico e a tomografia computadorizada helicoidal multislice foram estatisticamente superior a radiografia digital. A tomografia computadorizada helicoidal multislice e a tomografia computadorizada de feixe cônico não houve diferença estatisticamente insignificante. / The objective of this work and to compare the digital x-ray with the cone-beam computerized tomography and the multislice spiral computerized tomography in the diagnosis of external root resorption The 25 pigs jaws had been used, with 90 simulations of external root resorption carried through with round burs sizes of number ¼, ½ and 1 distributed uniformly for the three sites After the accomplishment of the radiography and tomography images, the images had been analyzed by three examiners. To get as resulted that the cone-beam computerized tomography identified 85.18%, the multislice spiral computerized tomography identified 87.77% and the digital x-ray identified only 45.92% of the external root resorptions. We conclude that the cone-beam computerized tomography and the multislice spiral computerized tomography had been statistical superior the digital x-ray. The multislice spiral computerized tomography and the cone-beam computerized tomography did not have statistical insignificant difference.
74

Estimativa de dose efetiva de radiação recebida por pacientes submetidos a exames de tomografia computadorizada e proposta para registro de dose por paciente em sistema de informação de radiologia / Effective dose estimate received by patients undergoing computed tomography scans and proposal to dose record per patient in a radiology information system

Paula Duarte Correia 21 November 2016 (has links)
A necessidade de estimar a dose efetiva de radiação recebida pelos pacientes em exames de tomografia computadorizada (TC) é muito discutida atualmente devido ao fato de que este exame está entre aqueles que mais depositam dose em pacientes submetidos a exames radiológicos. O objetivo deste trabalho foi implementar um método de estimativa de dose efetiva em exames de TC baseado em evidências bem estabelecidas e em informações contidas nas imagens. Após dosimetria realizada no equipamento de TC, mapeamento dos protocolos e definição dos fatores de correção a serem utilizados, uma rotina de processamento dos dados foi criada para conversão da informação do cabeçalho DICOM da imagem radiológica em dose efetiva estimada, de modo que as informações levantadas poderão ser disponibilizadas, em registro no sistema de informação de radiologia do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo - HCFMRP/USP, aos médicos e profissionais de saúde envolvidos. / Computed tomography scan is the procedure that most deposits radiation dose in patients undergoing radiologic examinations. That is the reason why the need to record the dose received is currently discussed. The aim of this study was to implement an method to estimate effective dose received in CT scans based on well-established evidences and information contained in images. After performing dosimetry in CT equipment, mapped protocols and define correction factors, a data processing routine was created for conversion of DICOM header information in estimated effective dose, so that the information raised could be avalable in Hospital\'s radiology information system for doctors and health professionals involved.
75

Avaliação da sensibilidade entre a radiografia difgital periapical direta e a tomografia computadorizada de feixe cônico, no diagnóstico de reabsorções tradiculares simuladas em "ex-vivo"/

Borges, Marco Aurélio Gagliardi. January 2009 (has links)
Orientador: Marcelo Gonçalves / Banca: Jorge E. Hayek / Banca: Eduardo Kazuo Sannomiya / Banca: Idomeo Bonetti Filho / Banca: Mario Tanomaru Filho / Resumo: O objetivo deste trabalho e de comparar a radiografia digital com a tomografia computadorizada de feixe cônico e a tomografia computadorizada helicoidal multislice no diagnóstico de reabsorções radiculares. Foram utilizadas 25 mandíbulas suínas, com 90 simulações de reabsorções realizadas com fresas de número ¼, ½ e 1 distribuídas uniformemente pelos três terços. Após a realização dos exames radiográficos e tomográficos, as imagens foram analisadas por três examinadores. Obtivermos como resultado que a Tomografia computadorizada de feixe cônico identificou 85,18%, a tomografia computadorizada helicoidal multislice identificou 87,77% e a radiografia digital identificou apenas 45,92% das reabsorções. Concluímos que a tomografia computadorizada de feixe cônico e a tomografia computadorizada helicoidal multislice foram estatisticamente superior a radiografia digital. A tomografia computadorizada helicoidal multislice e a tomografia computadorizada de feixe cônico não houve diferença estatisticamente insignificante. / Abstract: The objective of this work and to compare the digital x-ray with the cone-beam computerized tomography and the multislice spiral computerized tomography in the diagnosis of external root resorption The 25 pigs jaws had been used, with 90 simulations of external root resorption carried through with round burs sizes of number ¼, ½ and 1 distributed uniformly for the three sites After the accomplishment of the radiography and tomography images, the images had been analyzed by three examiners. To get as resulted that the cone-beam computerized tomography identified 85.18%, the multislice spiral computerized tomography identified 87.77% and the digital x-ray identified only 45.92% of the external root resorptions. We conclude that the cone-beam computerized tomography and the multislice spiral computerized tomography had been statistical superior the digital x-ray. The multislice spiral computerized tomography and the cone-beam computerized tomography did not have statistical insignificant difference. / Doutor
76

Avaliação do programa de controle de qualidade e segurança dos equipamentos PET instalados em regiões do Brasil / Avalation about quality control program and safety PET equipment installed in regions of the Brazil

Souza, Jeane Serrão de 26 November 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Gama, Engenharia Biomédica, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2015-02-04T13:19:50Z No. of bitstreams: 1 2014_JeaneSerraoSouza.pdf: 4881835 bytes, checksum: a7ef077f3198020ea6c61714a7892345 (MD5) / Approved for entry into archive by Ruthléa Nascimento(ruthleanascimento@bce.unb.br) on 2015-02-10T19:47:15Z (GMT) No. of bitstreams: 1 2014_JeaneSerraoSouza.pdf: 4881835 bytes, checksum: a7ef077f3198020ea6c61714a7892345 (MD5) / Made available in DSpace on 2015-02-10T19:47:15Z (GMT). No. of bitstreams: 1 2014_JeaneSerraoSouza.pdf: 4881835 bytes, checksum: a7ef077f3198020ea6c61714a7892345 (MD5) / Os equipamentos de tomografia computadorizada por emissão de pósitron (PET, do inglês Positron Emission Tomography) são utilizados nos serviços de medicina nuclear para realização de exames oncológicos, neurológicos e cardiológicos. A comprovação da eficácia desta técnica, impulsionou a instalação desses equipamentos no mundo. Para que as imagens permitam um diagnóstico com maior precisão, é necessário a realização de testes de desempenho para verificar se as condições de operação do equipamento estão adequadas dentro de um programa de controle de qualidade. Baseados na norma NN 3.05 – Requisitos de Segurança e Proteção Radiológica para Serviços de Medicina Nuclear da Comissão Nacional de Energia Nuclear (CNEN) e Resolução da Diretoria Colegiada n 38 - Sobre a Instalação e Funcionamento de Serviços de Medicina Nuclear “in vivo” da Agência Nacional de Vigilância Sanitária (ANVISA) verificou-se quais os testes estão sendo realizados e as periodicidades dominantes bem como os principais motivos que dificultam sua realização, como e quais são os registros realizados, as características dos equipamentos e equipe técnica, entre outros. A coleta dos dados baseou-se na aplicação de um questionário on line encaminhado por correio eletrônico aos supervisores de radioproteção dos serviços de medicina nuclear. Os dados foram analisados por meio da estatística descritiva com auxílio de gráficos, tabelas, verificação de hipóteses e correlações entre parâmetros com o auxílio do teste de Wilcoxon não pareado utilizando-se o software Matlab. Identificou-se que os testes que não são realizados estão relacionados com a ausência de acessórios e fantomas NEMA, falta de treinamento dos supervisores de radioproteção e deficiências nos treinamentos disponibilizados pelos fabricantes. Foi possível conhecer as perspectivas dos profissionais em relação ao tema, mapear as dificuldades e benefícios alcançados com a realização dos mesmos e desenvolver diretrizes para auxiliar os profissionais da área no planejamento, preparação e implantação de um programa de controle de qualidade de equipamentos PET. _______________________________________________________________________ ABSTRACT / The positron emission computed tomography equipment (PET) are used in nuclear medicine services to perform oncological, neurological and cardiological examinations. Evidence of the effectiveness of this technique, stimulated the installation of such equipment in the world. So that images allow a diagnosis more accurately, it is necessary to conduct performance tests to verify if the operating conditions of the equipment are appropriate within a quality control program. Based on norm NN 3.05 - Security Requirements for Radiological Protection and Nuclear Medicine Services of the National Nuclear Energy Commission (CNEN) and Resolution n 38 - About the installation and operation of nuclear medicine services "in vivo" of National Health Surveillance Agency (ANVISA) verify what tests are being conducted and the dominant periodicities as well as the main reasons that hinder their achievement, how and what are the comparisons of the characteristics of the equipment and technical staff, among others. Data collection was based on the application of an on line questionnaire sent by email to the radioprotection supervisors of nuclear medicine services. Data were analyzed using descriptive statistics with the aid of charts, tables, testing hypotheses and correlations between parameters with the Wilcoxon not paired test using the Matlab software. It was identified that the tests that are not performed are related to the lack of accessories and NEMA phantoms, lack of training for radioprotection supervisors and deficiencies in training offered by manufacturers. Was possible to know the views of professionals on the topic, map the difficulties and benefits achieved with their realization and develop guidelines to assist professionals in planning, preparation and implementation of a program of quality control of PET equipment.
77

Influência da base craniana sobre as dimensões transversais das bases apicais e dos arcos dentários / Influence of cranial base on transverse dimensions of apical bases and arches

Almeida, Carolina Pedrinha de 08 April 2011 (has links)
Esta pesquisa foi realizada para verificar se o padrão morfogenético da base craniana é determinante das dimensões transversais da maxila e mandíbula e se tal influência também se estende à porção alveolar das bases apicais. Complementarmente buscou-se avaliar as inclinações vestíbulo-linguais dos dentes posteriores com intuito de verificar se tais inclinações são padronizadas, independente das larguras das bases alveolares, ou se existem variações significativas. A amostra foi composta por 30 indivíduos adultos jovens, brasileiros, leucodermas com perfis faciais equilibrados e neutro-oclusão. Dividiu-se em dois grupos de acordo com a dimensão transversal da base anterior do crânio, definida pela distância entre os pontos esfenóide direito e esquerdo, sendo o grupo G1 composto pelos indivíduos apresentando valores menores que a mediana, e o grupo G2 com indivíduos apresentando valores maiores ou iguais a mediana. Foi realizada correlação intraclasse para avaliar o erro do método; média, mediana e desvio padrão para descrever o grupo amostral; teste t-Student para comparar os grupos G1 e G2; teste exato de Fischer para avaliar associação entre base do crânio e gêneros e Teste de Correlação Linear de Pearson. As medidas apresentaram alta reprodutibilidade. Indivíduos do grupo G2 apresentaram maior largura de mandíbula e maior espessura alveolar dos primeiros molares e primeiros pré-molares superiores. Não houve associação entre largura de base do crânio e gêneros. A largura basal da mandíbula apresentou correlação estatisticamente significante com a largura da base do crânio, assim como a largura alveolar maxilar na região de prémolares e molares superiores em relação à largura basal da maxila. As conclusões foram: a largura da base craniana apresenta correlação com a largura da mandíbula; a largura da maxila varia em consonância com a largura da mandíbula; a largura alveolar da maxila na região de primeiros pré-molares e molares superiores apresenta correlação com largura basal da maxila; a largura basal mandibular apresenta correlação com a largura alveolar da mandíbula na região dos primeiros pré-molares; as inclinações vestíbulo-linguais dos primeiros molares e primeiros prémolares são constantes, independentes das larguras basais e alveolares de suas respectivas bases ósseas. / This research intended to check if the morphogenetic pattern of cranial base determines transverse dimensions of upper and lower face and if it extends to alveolar portion basis. In addition evaluated buccal-lingual inclinations of posterior teeth to examine if they are standardized, regardless of the widths of the alveolar bases, or whether there are significant variations. The sample comprised 30 young adults, Caucasian Brazilian facial profiles with balanced and neutral occlusion. Divided into two groups according to the transverse dimension of the anterior skull base, defined by the distance between right and left sphenoid´s points, the G1 made of individuals with lower values than the median, and G2 with individuals with values greater or equal to median. Intraclass correlation was performed to evaluate the method error, mean, median and standard deviation to describe the sample group, Student t test to compare the groups G1 and G2, Fisher exact test to access the relation between skull base and genres and Test Linear correlation of Pearson. Measurements showed high reproducibility. G2 individuals showed greater mandible width and greater thickness of alveolar bone on upper first molars and first premolars. There was no association between width of skull base and genres. The width of the mandible showed a statistically significant correlation with the width of the skull base and maxillary alveolar width in premolars and molars in relation to basal width of jaw. Conclusions: the width of cranial base is correlated with width of jaw; jaw width varies in line with jaw width and width of maxillary alveolar region of first premolars and molars is correlated with basal width jaw, the basal mandibular width correlates with width of jaw in alveolar region first premolars; the buccolingual inclinations of the first molars and first premolars are constant, independent of basal width and alveolar bone of their respective bases.
78

Avalia??o das altera??es condilares ap?s cirurgia ortogn?tica atrav?s de superposi??o regional com tomografia computadorizada

Claus, Jonathas Daniel Paggi 28 March 2018 (has links)
Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-06-28T16:55:44Z No. of bitstreams: 1 JONATHAS_DANIEL_PAGGI_CLAUS_TES.pdf: 15775593 bytes, checksum: 5bac7d16a07d5e8df3ca1f344cccdfff (MD5) / Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2018-07-05T11:30:41Z (GMT) No. of bitstreams: 1 JONATHAS_DANIEL_PAGGI_CLAUS_TES.pdf: 15775593 bytes, checksum: 5bac7d16a07d5e8df3ca1f344cccdfff (MD5) / Made available in DSpace on 2018-07-05T11:41:25Z (GMT). No. of bitstreams: 1 JONATHAS_DANIEL_PAGGI_CLAUS_TES.pdf: 15775593 bytes, checksum: 5bac7d16a07d5e8df3ca1f344cccdfff (MD5) Previous issue date: 2018-03-28 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Purpose: The aim of the present study was to use cone-beam computed tomography (CBCT) regional superimposition to investigate the effect of bimaxillary advancement orthognathic surgery on condylar remodeling of the temporo mandibular joint (TMJ). Materials and Methods: Using a retrospective study design, 56 condyles from 28 healthy patients (age from 16 to 50 years) with mandibular retrognathism treated with bimaxillary advancement had CBCT scans taken pre-operatively and at an average 14 months postoperatively. Pre- and post-surgical scans were superimposed using regional and automated voxel-based registration to assess condylar changes in the follow-up period. The linear alterations were measured in six different areas of each condyle to assess the pattern of condylar remodeling. Results: Although no significant correlation was observed between changes in condylar surfaces, bone resorption occurred predominantly in the posterior and superior region, while bone formation was predominantly in the anterior surface. Medial and lateral surfaces presented fewer bone changes. The overall bone changes were smaller than 1mm in 48 condyles (85,7%) in 21 patients (75%). Conclusions: The results of this study suggest the hypothesis that alterations occurring in TMJ after performing orthognathic surgeries occur similar to an adaptive response, especially in healthy patients, other than a pathological or inflammatory process. Other studies with similar methodologies may clarify the mechanisms involved in cases where the process of condylar remodeling is more present. / Prop?sito: O objetivo do presente estudo foi utilizar a superposi??o regional de tomografia computadorizada do feixe c?nico (TCFC) para investigar o efeito da cirurgia ortogn?tica de avan?o bimaxilar no processo de remodela??o do c?ndilo da articula??o t?mporo mandibular (ATM). Materiais e m?todos: Usando um estudo do tipo retrospectivo, 56 c?ndilos de 28 pacientes saud?veis (idade de 16 a 50 anos) com retrognatismo mandibular tratados com cirurgia de avan?o bimaxilar tiveram exames de TCFC tomados no pr?-operat?rio e em uma m?dia de 14 meses no p?s-operat?rio. Foi utilizada superposi??o regional dos exames pr? e p?s-operat?rios com registro autom?tico por voxels para avaliar as altera??es condilares no per?odo de acompanhamento. As altera??es lineares foram mensuradas em seis diferentes ?reas de cada c?ndilo para avaliar o padr?o do processo de remodela??o condilar. Resultados: Embora n?o tenha sido observado correla??o significante das altera??es condilares entre cada superf?cie investigada, a reabsor??o ?ssea ocorreu mais predominantemente na regi?o superior e posterior, enquanto a aposi??o de osso neoformado foi mais predominante na superf?cie anterior. As superf?cies medial e lateral apresentaram as menores altera??es. As mudan?as no osso condilar em geral foram menores do que 1 mm em 48 c?ndilos (85,7%) em 21 pacientes (75%). Conclus?es: Os resultados deste estudo sugerem a hip?tese de que as altera??es ocorridas na ATM ap?s a realiza??o de cirurgias ortogn?ticas ocorrem com uma resposta adaptativa, especialmente em pacientes saud?veis, diferentes de um processo patol?gico/inflamat?rio. Outros estudos com metodologias semelhantes poder?o esclarecer quais os mecanismos envolvidos nos casos onde o processo de remodela??o condilar est? mais presente.
79

Estudo e aplicação do algoritmo FDK para a reconstrução de imagens tomográficas multi-cortes / Study and application of the FDK algorithm for multi-slice tomographic images reconstruction

Araujo, Ericky Caldas de Almeida 29 October 2008 (has links)
O presente projeto consistiu no estudo e aplicação do algoritmo FDK (Feldkamp-Davis-Kress) para a reconstrução de imagens tomográficas utilizando a geometria de feixe cônico, resultando na implementação de um sistema adaptado de tomografia computadorizada multicortes (TCMC). Para a aquisição das projeções, utilizou-se uma plataforma giratória com goniômetro acoplado, um equipamento de raios X e um detector digital, tipo CCD. Para processar a reconstrução das imagens, foi utilizado um PC, no qual foi implementado o algoritmo FDK. Inicialmente foi aplicado o algoritmo FDK original, no qual se assume o caso físico ideal no processo de medições. Em seguida, foram incorporadas ao algoritmo, algumas correções de artefatos relacionados ao processo de medição das projeções. Para testar o funcionamento do algoritmo implementado, foram feitas reconstruções a partir de projeções simuladas computacionalmente. Foram montados e testados três sistemas de aquisição de projeções, nos quais foram usados diferentes equipamentos de raios X, detectores, metodologias e técnicas radiográficas, a fim de garantir que fossem coletados os melhores conjuntos possíveis de projeções. Realizou-se a calibração do sistema de TCMC implementado. Para isso, utilizou-se um objeto com uma distribuição de coeficientes de atenuação linear conhecida, que foi projetado e fabricado especificamente para isto. Por fim, o sistema de TCMC implementado foi utilizado na reconstrução tomográfica de um objeto não homogêneo, cuja distribuição volumétrica do coeficiente de atenuação linear é desconhecida. As imagens reconstruídas foram analisadas a fim de avaliar o desempenho do sistema de TCMC implementado. / This work consisted on the study and application of the FDK (Feldkamp-Davis-Kress) algorithm for tomographic image reconstruction using cone-beam geometry, resulting on the implementation of an adapted multi-slice computed tomography (MSCT) system. For the acquisition of the projections, a rotating platform coupled to a goniometer, an x-ray equipment and a CCD type digital detector were used. The FDK algorithm was implemented on a PC which was used for the reconstruction process. Initially, the original FDK algorithm was applied considering only the ideal physical conditions in the measurement process. Then some artifacts corrections related to the projections measurement process were incorporated. Computational simulations were performed to test the functioning of the implemented algorithm. Three projections acquisition systems, which used different x-ray equipments, detectors, methodologies and radiographic techniques, were assembled and tested in order to ensure that the best possible set of data was collected. The implemented MSCT system was calibrated. A specially designed and manufactured object with a known linear attenuation coefficient distribution was used for this purpose. Finally, the implemented MSCT system was used for multi-slice tomographic reconstruction of an inhomogeneous object, whose attenuation coefficient distribution was unknown. The reconstructed images were analyzed to assess the performance of the TCMC system that was implemented.
80

Avaliação da aterosclerose coronária em pacientes com doença de Chagas por tomografia computadorizada de múltiplos detectores / Evaluation of coronary atherosclerosis in patients with Chagas disease by multidetector computed tomography

Cardoso, Sávio José de Meneses 26 July 2012 (has links)
INTRODUÇÃO: A doença de Chagas (DCh) representa um grave problema de saúde pública na maioria dos países da América Latina. Sintomatologia frequente, a dor torácica ou precordial em pacientes com DCh pode assemelhar-se àquela observada na doença arterial coronária (DAC), constituindo-se, dessa forma, em desafio diagnóstico para os clínicos. A frequência da DAC em pacientes com DCh continua indefinida na literatura, permanecendo a hipótese de que pacientes com DCh possam apresentar menor proporção de DAC. A angiografia coronária por tomografia computadorizada (ATC), em aparelho de múltiplas colunas de detectores, é um método não invasivo de alta acurácia que permite o diagnóstico precoce de placas ateromatosas, obstrutivas ou não, e que poderia detectar a frequência de DAC neste grupo de pacientes. OBJETIVO: Investigar a presença de aterosclerose coronária em pacientes com DCh, comparando com um grupo controle de indivíduos assintomáticos e sem doença coronária conhecida, utilizando a angiografia coronária por tomografia computadorizada. MÉTODOS: Foram estudados 43 pacientes portadores da DCh, sendo 16 (37,2%) homens. O grupo controle foi composto por 66 indivíduos não portadores da DCh, sendo 28 (42,4%) homens. Os grupos foram pareados pelo escore de risco de Framingham, respeitando-se a mesma faixa de risco (baixo, intermediário e alto), além do pareamento por sexo e faixa etária. Os exames foram realizados em tomografia computadorizada de 320 colunas de detectores e o diagnóstico de DAC foi definido pela presença de placa aterosclerótica, mesmo sem causar obstrução luminal. DAC obstrutiva significativa foi considerada pela presença de ao menos uma placa causando redução maior do que 50% do diâmetro da luz arterial. RESULTADOS: Foram observadas diferenças significativas nos parâmetros relacionados à DAC, sendo sua frequência significativamente menor nos pacientes portadores da DCh. A presença de DAC foi observada em 9 indivíduos (20,9%) portadores da DCh e em 32 indivíduos do grupo controle (48,5%), com p=0,004. A magnitude da estenose coronária foi significativamente menor nos pacientes com DCh que nos controles na análise por paciente, por território e por segmentos coronários (p<0,001, p=0,012 e p=0,045, respectivamente). CONCLUSÕES: Os pacientes portadores da DCh apresentam baixa frequência de DAC definida pela tomografia computadorizada de artérias coronárias. A frequência de DAC, obstrutiva ou não, em pacientes com DCh foi significativamente menor que a observada no grupo controle de pacientes sem DAC prévia conhecida / INTRODUCTION: Chagas disease (CD) is a serious public health problem in most of Latin American countries. Precordial or chest pain in patients with CD is a frequent symptom and can be similar to that observed in coronary artery disease (CAD), what represents a diagnostic challenge to the physicians. The frequency of CAD in patients with CD continues undefined in the literature, remaining the hypothesis that patients with CD could present a lower proportion of CAD. Computed tomography angiography (CTA) is a high accuracy and non-invasive method that allows an early diagnostic of atherosclerotic plaque, obstructive or not, and that could detect the frequency of CAD in this group of patients. OBJECTIVE: Investigate coronary atherosclerosis by CTA in patients with CD, comparing with an asymptomatic control group without known CAD. METHODS: 43 patients with CD were studied and 16 (37.2%) were men. The control group was composed by 66 non-carriers of CD and 28 (42.4%) were men. The groups were matched for Framingham risk score (low, medium and high) as well as sex and age. The exams were performed in 320-multidetector rows CT and the CAD diagnostic was defined as the presence of atherosclerotic plaques, even without luminal obstruction. Significant obstructive CAD was considered if at least one plaque was present causing more than 50% of reduction in the arterial lumen diameter. RESULTS: Significant differences were observed in parameters related to CAD, showing lower frequency of CAD in patients with CD. The presence of CAD was observed in 9 patients (20.9%) with CD and in 32 patients (48.5%) from the control group, with p=0.004. The magnitude of coronary stenosis was significantly lower in patients with CD than in controls, in a per patient, per territory and per segment coronary analyses (p<0.001, p=0.012 e p=0.045, respectively). CONCLUSIONS: Patients with CD have a low frequency of CAD defined by coronary CTA. The CAD frequency, obstructive or not, in patients with CD was significantly lower than the observed in the control group without known CAD

Page generated in 0.0789 seconds